Manual Control. Class 11 3RV, SMF, MMS. Wiring Diagrams 3RV1921-1M 8/127. Signaling Contact for Class 11-3RV. Class 11-3RV

Size: px
Start display at page:

Download "Manual Control. Class 11 3RV, SMF, MMS. Wiring Diagrams 3RV1921-1M 8/127. Signaling Contact for Class 11-3RV. Class 11-3RV"

Transcription

1 Manual ontrol lass RV, MF, MM lass - RV ignaling ontact for lass - RV RV9-M Typical lass MF Typical MM iemens Energy & utomation, Inc. 8/7

2 Heavy Duty Motor tarters lass Phase and ingle Phase Magnetic tarters mbient ompensated ingle Phase izes 00- / mbient ompensated Phase izes 00- / mbient ompensated Phase izes - olid tate Overload ingle Phase izes 0- olid tate Overload Phase izes 00- olid tate Overload Phase izes - olid tate Overload Phase Wired as Phase Warning: The EP00 tarter and ingle Phase Motor must be wired with polarity as shown. Neutral and wires must be wired as indicated on the drawing. Polarity is indicated by the arrows. 8/8 Full oad mps (F): djustment of the EP00 solid state overload relay () must be made as follows to accommodate the single phase motor: For an approximate setting of a single phase motor application, multiply the motor nameplate F by.7 and set the dial on the overload relay () to resulting value. The phase for frame size (without windows) can not be wired for single phase. Use the proper version for single phase. iemens Energy & utomation, Inc.

3 ombination Heavy Duty tarters lass 7, 8 Phase THREE PHE TO UPPY ize 0 DIONNET or V M W B TERNTE ONNETION FOR NFORMER REMOVE WIRE "" IF ON NFORMER I UED. FOR EPRTE ON VTGE OURE, REMOVE JUMPER "" ND "B" ND ONNET OURE TO ON FUE INE TERMIN. T T ON FUE (OPTION) OVEROD REY 9 9 XF E FUE H X T M T D H H H E X ize iemens Energy & utomation, Inc. 8/9

4 Reversing Heavy Duty tarters lass Phase olid tate Overload olid tate Overload izes 0- / olid tate Overload izes - olid tate Overload izes - TO UPPY "FWD" ONTOR OR "REV" OR MEHNI INTEROK URRENT NFORMER (EE TBE) O.. REY REMOVE WIRE "" IF THE OR OI I TO OPERTE ON VTGE OTHER THN INE VTGE OR ON EPRTE ON OURE. MOTOR Phase mbient ompensated Overload Bimetal Overload izes 0- / Bimetal Overload izes - / Bimetal Overload izes - ingle Phase mbient ompensated Overload Wire, Pole izes 0- / 8/0 iemens Energy & utomation, Inc.

5 ombination Reversing Heavy Duty tarters lass, Phase ize 0 TO UPPY DIONNET or TERNTE ONNETION FOR NFORMER B 0 V 9 FOR W 7 8 V REV W T T OVEROD REY 9 9 T M T 9 ON FUE (OPTION) E FUE XF H X D H E H X H ON NFORMER (OPTION) REMOVE WIRE "" IF ON NFORMER I UED. FOR EPRTE ON VTGE OURE, REMOVE JUMPER "" ND "B" ND ONNET OURE TO ON FUE INE TERMIN. TO UPPY ize "FWD" ONTOR OR "REV" OR MEHNI INTEROK URRENT NFORMER (EE TBE) O.. REY REMOVE WIRE "" IF THE OR OI I TO OPERTE ON VTGE OTHER THN INE VTGE OR ON EPRTE ON OURE. MOTOR iemens Energy & utomation, Inc. 8/

6 Two peed Heavy Duty tarters lass 0 & Non-ombination and ombination tarters Winding onstant Horsepower ize 0 / POITION PEED PEED TO UPPY DIONNET or ' 9 9 T T TOGETHER EEMENTRY DIGRM T 7 T T ONTNT HOREPOWER MOTOR T 8 TO UPPY DIONNET or V W OVEROD REY 9 9 T T T T 7 M WIRING DIGRM 8 V W OVEROD REY 9 9 B 9 ON FUE (OPTION) ON NFORMER (OPTION) E FUE XF H X D H E H X H D87800 Winding onstant Horsepower ize TO UPPY DIONNET or ' 9 9 POITION TOGETHER PEED T T PEED EEMENTRY DIGRM T T ONTNT HOREPOWER MOTOR T 7 8 T D87800 DIONNET or B TO UPPY V O W OVEROD REY 9 9 V HI W OVEROD REY 9 9 T T 7 WIRING DIGRM MOTOR 8 V H W T T 9 ON FUE (OPTION) E FUE XF H X D H E H X H ON NFORMER (OPTION) Winding onstant or Variable Torque ize 0 / TO UPPY DIONNET or ' 9 9 POITION TOGETHER PEED T T PEED T T EEMENTRY DIGRM T T T T T ONTNT TORQUE MOTOR T VRIBE TORQUE MOTOR 7 8 TO UPPY DIONNET or V W OVEROD REY 9 9 T T WIRING DIGRM 7 M 8 V W B 9 ON FUE (OPTION) OVEROD REY 9 9 ON NFORMER (OPTION) T T E FUE XF H X D H H H E X D / iemens Energy & utomation, Inc.

7 Winding onstant or Variable Torque ize Two peed Heavy Duty tarters lass 0 & Non-ombination and ombination tarters TO UPPY DIONNET or POITION PEED PEED T ' 9 9 T TOGETHER T EEMENTRY DIGRM H T H T T T H T ONTNT TORQUE MOTOR VRIBE TORQUE MOTOR H 7 T H T 8 H D87800 TO UPPY WIRING DIGRM DIONNET or B V O W OVEROD REY 9 9 V HI W OVEROD REY 9 9 T T 7 MOTOR 8 V H T W T 9 ON FUE (OPTION) E FUE XF H X D H E H X H ON NFORMER (OPTION) Winding onstant Horsepower & Winding onstant or Variable Torque ize 0 EEMENTRY DIGRM TO UPPY DIONNET or T T T T T T T T TWO WINDING MOTOR ' POITION PEED T T 7 PEED T T TO UPPY DIONNET or V W T T OVEROD REY 9 9 T T T T WIRING DIGRM M 7 8 V W T T OVEROD REY 9 9 B 9 D XF H ON FUE (OPTION) ON NFORMER (OPTION) E FUE H H H E X X D87800 iemens Energy & utomation, Inc. 8/

8 Heavy Duty ontactors and Reversing ontactors lass 0, Phase Magnetic ontactors and Reversing ontactors Phase ontactors ize 00 Phase Reversing ontactors ize 00 Phase ontactors ize, Phase Reversing ontactors ize, TO UPPY "FWD" ONTOR OR "REV" OR MEHNI INTEROK URRENT NFORMER (EE TBE) REY REMOVE WIRE "" IF THE OR OI I TO OPERTE ON VTGE OTHER THN INE VTGE OR ON EPRTE ON OURE. OD ingle Phase Magnetic ontactors and Reversing ontactors ingle Phase ontactors ize 00 ingle Phase Reversing ontactors ize 00 P 8/ iemens Energy & utomation, Inc.

9 Duplex Heavy Duty ontrollers lass 8, 8 tandard Duplex Pump Panel (9) Duplex Panel w/o alternator (9) iemens Energy & utomation, Inc. 8/

10 Duplex Heavy Duty ontrollers lass 8, 8 Duplex Panel with Relay lternation (9) Duplex Panel with ead Pump Transfer witch (9) 8/ iemens Energy & utomation, Inc.

11 EK E W MB EK E W MB OPTION DIONNET OR EK E W MB MB W E EK MB W E EK tandard and Reduced Voltage Pump Panels lass 87, 88 tandard Pump Panel uto Transformer Part Winding TO UPPY T R 00% 80% % 0% 0% T T R 00% 80% % 0% 0% MOTOR FOR MOTOR HP EE ONER NMEPTE T FOR TRTER IZE -, T-T RE NOT UED. R 00% 80% % 0% 0% T FU () 7 R 7 7 FU R 77 () R () MEH INTK R FU H H FU T FU X PT X JUMPER NOTE E ONNET VTGE PEIFIED PER NMEPTE UPPIED REQUIRED () (9) (9) X NOT () R ONNETION FOR OPTION DEVIE TRT TOP PB PB HND TRT PB URGE UPPREOR () () R HND ETM RUN/ON/ RUNNING T ON IPPED 9 X T /TOP 0 X T OPTION DEVIE RE FURNIHED PER ONT DOUMENT iemens Energy & utomation, Inc. 8/7

12 Reduced Voltage Pump Panels lass 88 Wye Delta (Open Transition) Wye Delta (losed Transition) UTOMER' IN. INE ÿ Bÿ ÿ OPTION DIONNET OR M T T UTOMER' IN. INE ÿ Bÿ ÿ OPTION T M DIONNET OR M T T T T FOR TRTER IZE -, T-T RE NOT UED. M M M M T T T T T T T FOR TRTER IZE -, T-T RE NOT UED. M M M M M RE RE B T RE T T T FU 0 M M R () 7 () M () M FU MEH INTEROK FU 0 M 7 R () () 8 () M FU MEH INTEROK FU UPPIED REQUIRED FU M () M FU H H H H ONNET VTGE PT PEIFIED X X X PER NMEPTE X FU FU UPPIED REQUIRED FU H H H H ONNET VTGE PT PEIFIED X X X PER NMEPTE X () (9) (9) X NTO () R NTO () R () (9) (9) X ONNETION FOR OPTION DEVIE TRT URGE UPPREOR TOP () PB PB () HND TRT R PB ETM HND RUN/ON/ RUNNING T IPPED 9 X T ON /TOP 0 X T ONNETION FOR OPTION DEVIE TRT URGE UPPREOR TOP () PB PB HND TRT () R PB ETM HND RUN/ON/ RUNNING T IPPED 9 X T ON /TOP 0 X T OPTION DEVIE RE FURNIHED PER ONT DOUMENT OPTION DEVIE RE FURNIHED PER ONT DOUMENT 8/8 iemens Energy & utomation, Inc.

13 EK E W MB EK E W MB OPTION DIONNET OR EK E W MB MB W E EK MB W E EK Reduced Voltage tarters lass, 7 Part Winding uto Transformer TO UPPY T R 00% 80% % 0% 0% T T R 00% 80% % 0% 0% MOTOR FOR MOTOR HP EE ONER NMEPTE T FOR TRTER IZE -, T-T RE NOT UED. R 00% 80% % 0% 0% T FU () 7 R 7 7 FU R 77 () R 78 MEH INTK 79 () R FU H H FU T FU X PT X JUMPER NOTE E ONNET VTGE PEIFIED PER NMEPTE UPPIED REQUIRED X () (9) (9) NOT () R ONNETION FOR OPTION DEVIE TRT TOP PB PB HND TRT PB URGE UPPREOR () () R HND ETM RUN/ON/ RUNNING T ON IPPED 9 X T /TOP 0 X T OPTION DEVIE RE FURNIHED PER ONT DOUMENT iemens Energy & utomation, Inc. 8/9

14 Reduced Voltage tarters lass, 7 Wye Delta (Open Transition) Wye Delta (losed Transition) UTOMER' IN. INE ÿ Bÿ ÿ UTOMER' IN. INE ÿ Bÿ ÿ OPTION DIONNET OR M T T OPTION DIONNET OR M T T T T RE T T M M M M T T T T T T M M M M M RE B T RE T T T FOR TRTER IZE -, T-T RE NOT UED. M FOR TRTER IZE -, T-T RE NOT UED. FU 0 M R () FU FU 0 M R () 7 () M FU MEH INTEROK 7 () 8 () M MEH INTEROK M () M M () M UPPIED REQUIRED FU FU H H H H ONNET VTGE PT PEIFIED FU X X X PER NMEPTE X FU FU UPPIED REQUIRED FU H H H H ONNET VTGE PT PEIFIED X X X PER NMEPTE X NTO () R () (9) (9) X () (9) (9) X NTO () R ONNETION FOR OPTION DEVIE ONNETION FOR OPTION DEVIE TRT URGE UPPREOR TOP () PB PB () HND TRT R PB ETM HND RUN/ON/ RUNNING T IPPED 9 X T ON /TOP 0 X T TRT URGE UPPREOR TOP () PB PB HND TRT () R PB ETM HND RUN/ON/ RUNNING T IPPED 9 X T ON /TOP 0 X T OPTION DEVIE RE FURNIHED PER ONT DOUMENT OPTION DEVIE RE FURNIHED PER ONT DOUMENT 8/0 iemens Energy & utomation, Inc.

15 ighting and Heating ontactors Electrically Held, lass E 0 MP 0 00 MP MP iemens Energy & utomation, Inc. 8/

16 ighting and Heating ontactors Mechanically atched 0 mp, lass M ON OR ON VTGE 0 ON TYPI -ON EETOR WITH OMMON OR EPRTE ON INE ON MODUE VTGE ON R R R R WIRE ON. 8 R R 0 ON OI PIOT IGHT REQUIRE () E. M0979 UXIIRY KIT. ON OR ON VTGE OR ON VTGE ON MODUE VTGE HND R R R 0 OI ON MODUE VTGE R R R R R 0 OI REMOTE ON ON WIRE ON. 7 ON- (FORM ) ON. 9 ON ONNETION TO ON MODUE OR ON VTGE MODUE TERMIN ONNET TO: ON MODUE VTGE ON- R R R WIRE ON. 7 0 ON OI O NOT UED ONT. TTION FOR. 8 & 9 ONT. TTION FOR. 7,8 & 9 MODUE ON VTGE OR ON VTGE TERMIN O ON OR " TERMIN ON OR " FOR VD ON MODUE ONNET TERMIN TO NEGTIVE (-) " " 8/ iemens Energy & utomation, Inc.

17 ighting and Heating ontactors Mechanically atched 0-00 mps, lass M Mechanically atched, M 0 00 mps onnection Diagram for ommon/eparate ontrol with Momentary Pushbutton or ON- elector witch MO, MOD, MOE, and MOF onnection for -Wire ontrol MO, MOD, MOE, and MOF onnection for Hand/Off/uto ontrol MO, MOD, MOE, and MOF Mechanically atched Type M 00 and 00 mp onnection Diagram for ommon/eparate ontrol with Momentary Pushbutton or ON- elector witch MOG and MOH onnection for -Wire ontrol MOG and MOH onnection for Hand/Off/uto ontrol MOG and MOH ontrol relay is required for wire and Hand/Off/uto ontrol, as shown in diagram. iemens Energy & utomation, Inc. 8/

18 Industrial ontrol Power Transformers lass MT, MTG Voltage etter Voltage etter B Voltage etter When secondary fuse clips are installed, Terminal X becomes XF Voltage etter D When secondary fuse clips are installed, Terminal X becomes XF Voltage etter E When secondary fuse clips are installed, Terminal X becomes XF Voltage etter F When secondary fuse clips are installed, Terminal X becomes XF Voltage etter G When secondary fuse clips are installed, Terminal X becomes XF Voltage etter H When secondary fuse clips are installed, Terminal X becomes XF Voltage etter I When secondary fuse clips are installed, Terminal X becomes XF Voltage etter J Does not include secondary fuse clips Voltage etter Does not include secondary fuse clips Voltage etter M When secondary fuse clips are installed, Terminal X becomes XF Does not include secondary fuse clips When secondary fuse clips are installed, Terminal X becomes XF H Voltage etter P 80V H Includes secondary fuse clips on sizes 0-70V Includes secondary fuse clips on sizes 0-00V econdary fuse clips are not included on MTG transformers. V X X Does not include secondary fuse clips 8/ iemens Energy & utomation, Inc.

L2 FWD REV L1 L2 L1 L2 L3 FWD REV (L.H. UNIT) (R.H. UNIT) HIGH LOW HIGH LOW

L2 FWD REV L1 L2 L1 L2 L3 FWD REV (L.H. UNIT) (R.H. UNIT) HIGH LOW HIGH LOW Manual ontrol lass - RV, SMF, MMS 0/0/ lass - RV Signaling ontact for lass - RV Typical lass SMF RV9-M Typical MMS Reversing Manual Starter and Manual Motor Starting Switches -Speed Manual Motor Starting

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

Motor Control Center Type

Motor Control Center Type Motor ontrol enter Type -00 upersedes RP.0.0.. pages -24, dated eptember 0 escription Page Motor ontrol enter Type -00 Unitrol istributor Ordering Instructions................................. 2 Procedure

More information

NEMA Contactors & Starters A200

NEMA Contactors & Starters A200 March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product

More information

SMP-2 Overload Relay. Product Selection Overview Feature SMP-1 SMP-2 SMP-3 TABLE OF CONTENTS. Description Page Description Page

SMP-2 Overload Relay. Product Selection Overview Feature SMP-1 SMP-2 SMP-3 TABLE OF CONTENTS. Description Page Description Page 3 ulletin 93 ulletin 93 SMP- Overload Relay SMP-3 Overload Relay SMP-2 Overload Relay Product Selection Overview Feature SMP- SMP-2 SMP-3 Self-Powered 3.2: djustment Range Phase Loss Protection Selectable

More information

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

Operation and Protection of Motors up to 600Hp at 460Vac (800A) Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components

More information

Accessories - Field Installable

Accessories - Field Installable Accessories - Field Installable A7 ontactors Type 1 General Purpose Enclosures ➋➌ Starters & Enclosed Products Enclosure (Box) Kit Includes: Hinged cover Backpan pre-drilled for listed arrangements (not

More information

Starters + Enclosed Product

Starters + Enclosed Product Starters + Enclosed Product General Description... 2 atalog Number oding... 4 Enclosure Ratings... 6 The Orange Express Program... 8 ustom ontrol Panels... 10 Fractional Manual Starters... 12 KWIKstarters...

More information

E C N A A F -

E C N A A F - 33-52 NA ontactors & Starters 3-Phase agnetic Starters nclosed Freedom Line January 1 Vol. 2, Ref. No. [0068] Selection Table 33-102. NA Freedom Line nclosed ontrol ing System 33 esign Page N - NA 33-40

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16DN0 NM Size 1 Starter.1 Freedom Series Product Overview........................................ Features, enefits and Functions............................ Standards and

More information

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up Master atalog 125 s and ontactors Section R Product Bulletin R1000 Issue Date 0493 R1000 Series s The R1000 Series s switch line voltage devices from low voltage controllers. Plug-in DPDT relays and snap-in

More information

Valve Products. B Series Valve

Valve Products. B Series Valve atalog 000- arker neumatic Valve, an exceptional performing industrial valve in a compact size with an enhanced flow range. vailable in solenoid pilot operated and remote air pilot models. he series features

More information

Starters. NEMA Contactors & NEMA Contactors & Starters Contents

Starters. NEMA Contactors & NEMA Contactors & Starters Contents January Vol., Ref. No. [007] - NM ontactors & Starters ontents Page Freedom Line Product Family Overview......................................... - ontactors Non-reversing and Reversing.........................

More information

Motor Control Center Type W

Motor Control Center Type W Motor ontrol enter upersedes RP.0.06.. pages -24, dated eptember 2000 escription Page Motor ontrol enter istributor Ordering Instructions................................. 2 Procedure for Identifying M

More information

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as

More information

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th NM ontactors and Starters NM N16N0 NM Size 1 Starter.1 Product Overview.............................................. Features, enefits and Functions.................................. Standards and ertifications......................................

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16N0 NM Size 1 Starter NM Size 1 ontactor.1 Product Overview.............................................. 242 Features, enefits and Functions..................................

More information

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors Selection ompact Definite Purpose Motor ontrol TLOG SELETION Definite Purpose ing System 2 D N 2 Model = ontactor = Three-Phase Starter = Single-Phase Starter Type 2 = Non-Reversing 27 = Non-Reversing

More information

equipment transformers single-phase

equipment transformers single-phase equipment tranformer connection trip upplied up to 450 V (except at.no 428 46) 428 40 + 428 99 428 41 upplied with connection trip 428 75 427 92 IP 2X or XX up to 450 V (up to 310 V in 12-24 V) - IK 04

More information

Contactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents

Contactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents Definite Purpose ontactors & Starters - July 007 Definite Purpose ontactors & Starters ontents Description Page Product Family Overview pplication Description........................................ -

More information

Rotary cam switches A&Z series

Rotary cam switches A&Z series Rotary cam switches &Z series Rotary cam switches &Z ONTNTS ONTNTS 2 GNR 3 STNDRD MOUNTING ORMS MOUNTING S 4 DIMNSION DRWINGS 5-6 OPTION XTRS 7-8 THNI DT 9 DIMNSION DRWINGS OR OPTION XTRS 10-12 ORDR SHT

More information

Table of Contents Safety Information 2 2 Danger! 2 2 Wiring Notes: PLEASE READ PRIOR TO INSTALLATION. 2 2 Applicable Codes 2 2

Table of Contents Safety Information 2 2 Danger! 2 2 Wiring Notes: PLEASE READ PRIOR TO INSTALLATION. 2 2 Applicable Codes 2 2 Mounting and hapter Initial Startup 2 Table of ontents Safety Information 2 2 Danger! 2 2 Wiring Notes: PLEASE READ PRIOR TO INSTALLATION. 2 2 Applicable odes 2 2 Motor Dimensions 2 3 MTF T-Frame Single-phase

More information

EIC combination motor starters

EIC combination motor starters pplications: Harsh and hazardous motor control environments, including refineries, chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining cross-the-line starting

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - A6 Series A6 Series Miniature Switches and Pilot Devices: 16mm Key features: 16mm (/8 ) mounting hole ED illumination ompact design saves space Momentary, Maintained, Selectors, and E-Stops Gold-clad

More information

Heavy Duty Motor Starters

Heavy Duty Motor Starters «% Heavy Duty Motor Starters Melting oy Overload, Manual Reset lass Selection Ordering Instructions oil Table Use complete catalog number. Replace the (*) with letter from the coil table. Dual voltage

More information

With Auto Switch/Double Acting Type, Single Acting Type. Bore Size (mm) : ф12, ф16, ф20, ф25, ф32, ф40, ф50, ф63, ф80, ф100. Symbol.

With Auto Switch/Double Acting Type, Single Acting Type. Bore Size (mm) : ф12, ф16, ф20, ф25, ф32, ф40, ф50, ф63, ф80, ф100. Symbol. With Auto witch/double Acting Type, ingle Acting Type Bore ize : ф, ф16,,,,,,, ф, ф PA AVIN DIN IT WIT BOR IZ AUTO WIT APAB YINDR FOR PIA APPIATION MANUFATURIN RTIFID TO IO 91&9 TANDARD ymbol Double Acting

More information

Starting of Induction Motors

Starting of Induction Motors 1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding

More information

Definite Purpose Control. Product Focus

Definite Purpose Control. Product Focus Product Focus Innovation in Eaton s utler-hammer efinite Purpose (P) ontactors are designed to improve control of refrigeration, air conditioning, ventilation and resistance heating applications. The

More information

ELECTRICAL SYSTEMS 4 F WIRING DIAGRAMS

ELECTRICAL SYSTEMS 4 F WIRING DIAGRAMS EECTRIC SYSTEMS 4 F WIRING DIGRMS Table of Contents Page Wiring Colors for MerCruiser............... 4F- Engine.................................. 4F- MCM (Stern Drive)..................... 4F- MIE (Inboard)

More information

Magnetic Motor Controls

Magnetic Motor Controls ^p Magnetic Motor ontrols NMA atalog Numbering System General SP urre it Range la ombination Starter (Non Fusible, Fusible) ombination Starter (ircuit Breaker) Reversing ombination Starter (Non Fusible,

More information

ESW/PESW. Non-Combination Starters

ESW/PESW. Non-Combination Starters ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - 6 Series Key features: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB terminal options Available assembled or as sub-components Worldwide approvals Incandescent

More information

G6125C, 2-Way, Pressure Compensated Flanged Globe Valve

G6125C, 2-Way, Pressure Compensated Flanged Globe Valve G6125, 2-ay, Pressure ompensated langed Globe Valve pplication This valve is typically used in large air handling units on heating or cooling coils. This valve is suitable for use in a hydronic system

More information

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors .2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in

More information

150 C 30 F B D 8L 152H C 30 F BD 43 8L

150 C 30 F B D 8L 152H C 30 F BD 43 8L SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number ode Solid-State ontroller b ontroller Type ode SM- c Ampere s ode A A A A A A A A A A

More information

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts 0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

G7150D, 3-Way, Diverting Flanged Globe Valve

G7150D, 3-Way, Diverting Flanged Globe Valve G7150D, 3-ay, Diverting Flanged Globe Valve pplication This valve is typically used in Large ir Handling Units on heating or cooling coils. This valve is suitable for use in a hydronic system with variable

More information

CJ2-Z. Cushion. Rubber bumper (Standard) Air cushion

CJ2-Z. Cushion. Rubber bumper (Standard) Air cushion eries ow to Order 1/ /22 J2 ø1, ø ir ylinder Ro lean series 1 ushion Rubber bumper (tandard) ir cushion 1 J 2 L R M9W 21 J 2 L R M9W opper, fluorine and siliconefree + Low particle generation 21 22 Vacuum

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,

More information

TMU045018HLXXXA,TMU045018HLXXXB

TMU045018HLXXXA,TMU045018HLXXXB TMU04508HLXXX,TMU04508HLXXXB onstant urrent Linear Module OMPLINT High Density, high brightness chip array for use in lass Linear applications onstant current for maximum efficacy Onboard connector for

More information

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION 1-3 MANUAL STARTERS EXERCISE OBJECTIVE Examine and describe the operation of manual motor starters. DISCUSSION Motor starters are made out of power switches and overload protection devices. They can be

More information

Practical and completely safe

Practical and completely safe FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with

More information

Section 3 SCHEMATICS PAGE CONTENTS

Section 3 SCHEMATICS PAGE CONTENTS ection EMTI ONTENT PGE ydraulic chematic............................................. - Electrical chematic, of....................................... - Electrical chematic, of.......................................

More information

Valve Mounted Cylinder. Action Built-in magnet. With air cushion. Double acting. Standard. Nonrotating rod. Standard. rod. Standard. rod.

Valve Mounted Cylinder. Action Built-in magnet. With air cushion. Double acting. Standard. Nonrotating rod. Standard. rod. Standard. rod. eries V/MVGQ,,,, 2,,,, 63,, eries Variations eries eries V ction uilt-in magnet With air cushion variations uilt-in One-touch fitting With auto switch With strong scraper Page RE RE X ouble acting -1-

More information

9070T150D1 Industrial Control Transformer, 150VA

9070T150D1 Industrial Control Transformer, 150VA Product Data Sheet 9070T150D1 Industrial ontrol Transformer, 150 Technical haracteristics Application Approvals atalog Reference Number Depth Height Width Winding Material Temperature Rise Type Primary

More information

240 / 480 Volt Grounded Neutral Supply (Single-Phase 3-Wire) Fused 3 Pole Disconnect (Note 1) 3 Pole Contactor 240 Volt Coil.

240 / 480 Volt Grounded Neutral Supply (Single-Phase 3-Wire) Fused 3 Pole Disconnect (Note 1) 3 Pole Contactor 240 Volt Coil. d 3 Pole (ote ) 3 Pole ontactor 0 Volt oil 0 / 40 Volt rounded Supply (Single-Phase 3-Wire) 0 Volt Photo- ine oad 0 mp ontrol (ote ) d 3 Pole (ote ) 40 / 480 Volt rounded Supply (Single-Phase 3-Wire) 40

More information

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

Operation and Protection of Motors up to 600Hp at 460Vac (800A) Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components

More information

T: +44 (0) F: +44 (0) E:

T: +44 (0) F: +44 (0) E: CONTROL UNIT AE s control s offers a good working environment, adapted to all types of facilities. The right choice of control s is energy-saving and provides the lowest possible noise levels. automation

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

Pump Panels Type 3R Enclosure

Pump Panels Type 3R Enclosure Type R Enclosure Product Family Overview June 6 Product escription The utler-hammer Pump ontrollers from Eaton s electrical business are combination starters with accessories and modifications designed

More information

4100 SERIES. Specifications: Applications:

4100 SERIES. Specifications: Applications: 400 ERIE pecifications: Widths up to 2 (05) engths up to 6 (,829) The (25) diameter drive pulley. oad capacity up to 80 lbs.* (6kg). elt speeds to 255 ft./min. (78 M/min.). pplications: Metal Forming Metal

More information

*70954* 240V Senior Swing Control Box Installation Instructions CAUTION WARNINGS. Table of Contents

*70954* 240V Senior Swing Control Box Installation Instructions CAUTION WARNINGS. Table of Contents *70954* 70954 2800 Overhead Concealed eries 9500 urface Applied eries 240V enior wing Control Box Installation Instructions CAUTION These instructions are presented in step-by-step sequence. It is very

More information

DMC-500 TM. DC Motor Drive Control. Operation / Installation Manual Manual Part Number: S8M5003 Date: August 11, Computer Weld Technology, Inc.

DMC-500 TM. DC Motor Drive Control. Operation / Installation Manual Manual Part Number: S8M5003 Date: August 11, Computer Weld Technology, Inc. omputer Weld Technology, Inc. 070 Old ammel N Houston Rd. Houston, TX 77086 Telephone: (7) 46-8 Fax: (7) 46-50 DM-500 TM D Motor Drive ontrol Operation / Installation Manual Manual Part Number: S8M500

More information

Industrial Control Power Transformers Class MT

Industrial Control Power Transformers Class MT Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

Electronic Timer - Series Micon 225 Signal Based Multi - Function

Electronic Timer - Series Micon 225 Signal Based Multi - Function Electronic imer - eries Micon 225 ignal Based Multi - Function Multi-function with ignal tart and upply tart. 16 iming Functions selected by DIP switch. wo independent relay outputs with either both relays

More information

Efficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions

Efficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions fficor* onformity to standards /N 60947-1 04 /N 60947-4-1 UL508 /N 60947-5-1 UL486 /N 60947-5-4 S22- N500 N 16 101/102 N50012 N50005 pprovals/marking mbient conditions Storage temperature -55º to +80º

More information

Efficor. Most reliable technology. High installation benefits. Best in class. Standards. Approvals. Global contactors. Intro. J/X New A.

Efficor. Most reliable technology. High installation benefits. Best in class. Standards. Approvals. Global contactors. Intro. J/X New A. Most reliable technology igh installation benefits lobal contactors Standard materials for food & beverage and transportation purposes complying the latest rail standards ighest reliable product performance

More information

Headlight Switch Connector. Brake Switch. Lead Wires. Main Power Feed from Starter. Fuse Box Connections (viewed from underside)

Headlight Switch Connector. Brake Switch. Lead Wires. Main Power Feed from Starter. Fuse Box Connections (viewed from underside) 0 Heller Pl #17 W ellmawr, NJ 0031 6-933-001 TH KT DOE NOT UPPORT TOCK (ORGNL) GENERTOR. THE DEGN OF THE KT DEGNED TO UPPLY MORE POWER THN THE GENERTOR LE TO UPPLY. 16 6 4D 4C 4D 0 0 0 4C 4 4 43 7 39 3

More information

NEW EFD fuse disconnector

NEW EFD fuse disconnector NEW EFD fuse disconnector More space for finger to open fuse carrier Advantages of cylindrical fuse disconnector EFD ompliance with IE 60947-1, IE 60947-3, UL 4248-1, UL 4248-4, UL 4248-8, UL 486E and

More information

COLOR DIAGRAMS. Table of Contents. Section 6

COLOR DIAGRAMS. Table of Contents. Section 6 Table of ontents OLOR DIGR ection OLOR DIGR 00 Optiax Jet Drive Engine Wiring............................ - 00 Optiax Jet Drive Typical Key witch Wiring.................. -5 00 Optiax Jet Drive Typical

More information

* Optional PRESSURE COMPENSATOR - FLANGED TYPE B A X 2.2. Typical application VR5P with flow control valve

* Optional PRESSURE COMPENSATOR - FLANGED TYPE B A X 2.2. Typical application VR5P with flow control valve * Veljan 3 ports pressure compensator Valve are designed for improved operation safety and reduced mountg cost. These valves are used to mata a constant pressure drop External PD, External PP Internal

More information

GH INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

GH INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR FATORY SET Wiring See page 6 for other wiring configurations O W N E R S M A N U A L GH INDUSTRIAL DUTY OMMERIAL DOOR OPERATOR YEAR WARRANTY Serial # Box Installation Date NOT FOR RESIDENTIAL USE Wiring

More information

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of

More information

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1 GE 8000-Line -1 Mains, coming Lines MAINS GENERAL Main units consist of an externally operable circuit disconnect, either a fusible switch or a circuit breaker. Sizes by ampere rating, short-circuit rating,

More information

GTEC Transfer switch Open transition

GTEC Transfer switch Open transition GTE Transfer switch Open transition 40-2000 amp Description GTE transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K A-600

FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K A-600 FIRE DOOR OPERATOR LOGI BOARD REPLAEMENT KIT K79-13493A-600 APPLIATI Replacement of logic board for model FDO-AU operator with fi rmware version 600. INSTALLATI REMOVE A AND D POWER 1. Disconnect A power

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

Headlight Switch Connector. Brake Switch. Lead Wires. Main Power Feed from Starter

Headlight Switch Connector. Brake Switch. Lead Wires. Main Power Feed from Starter 40 3C 40, 2E 2C 2 2F Dimmer witch 12 11 & 11 2C 2 Horn Relay Dome Courtesy feed 40 16 Main Power Feed from tarter 2 12 V attery rake witch rake witch 40 17 17 rake witch Third rake Light Headlight witch

More information

MHL2. Series 11- ø10, ø16, ø20, ø25. Parallel Type Wide Opening Air Gripper. How to Order. Model/Stroke. Clean series 11 Vacuum suction type

MHL2. Series 11- ø10, ø16, ø20, ø25. Parallel Type Wide Opening Air Gripper. How to Order. Model/Stroke. Clean series 11 Vacuum suction type eries ML2 ø, ø, ø, ø, ø, ø Parallel Type Wide pening ir ripper ow to rder lean series Vacuum suction type ML 2 22 ML 2 MN MN Wide opening Number of fingers 2 2 fingers ore size mm mm mm mm mm mm opper,

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

Electronic Faucet 1500T & 1501T Series

Electronic Faucet 1500T & 1501T Series Electronic Faucet 1500T & 1501T Series Specification: (example) Battery (4 cell) or Hardwire (24 V) infrared electronic handwash system H 2OPTIS technology no external adjustments required hrome plated

More information

Industrial Control Power Transformers

Industrial Control Power Transformers 09/10/15 Class MT Features b Enclosed coils (50-5000); Completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Bettis EHO Electro-Hydraulic Operator

Bettis EHO Electro-Hydraulic Operator ettis Electro-Hydraulic Operator The ettis is a self-contained, quarter-turn, valve actuator that combines proven technologies from Emerson s Valve utomation. The actuator has been designed for critical

More information

Circuit board for R-471/472/481/482 with 1/8 NPT ports SUPPLY. 1/8 NPT typ.

Circuit board for R-471/472/481/482 with 1/8 NPT ports SUPPLY. 1/8 NPT typ. CM-0 Circuit board for R-/// with / NPT ize: x / x / thick - module Use: Port #, the supply to the pilot valve, is connected to the main supply port #. Provides / NPT in the top of the circuit board..000.00..9

More information

Select Output & Color Temperature

Select Output & Color Temperature IP67 WET RTED SURFE WR TYPE WR Type IP67 Wet Rated Flexible Linear Lengths Preassembled up to 32 ft. (384 in)* Regulated by class 2 circuit limitations Refer to driver data sheet for max lengths IP67 Wet

More information

Standard voltages. Alternating current (V) /60Hz Alternating current (V)

Standard voltages. Alternating current (V) /60Hz Alternating current (V) Three and four pole contactors 50 to 825 (3) 200 to 250 () ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K3: auxiliary

More information

GE Industrial Solutions. New. Ed. 02. New contactors and starter combinations for demanding applications. GE imagination at work

GE Industrial Solutions. New. Ed. 02. New contactors and starter combinations for demanding applications. GE imagination at work GE Industrial Solutions New Ed 02 New contactors and starter combinations for demanding applications GE imagination at work Efficor - new dimension in global contactors dvantages and enefits 2 Introduction

More information

SMD2. Compact cylinder. Space saving structure 6, 10, 16 20, 25, 32. Simple square design. Switch integrated. Easy centering. Precise installation

SMD2. Compact cylinder. Space saving structure 6, 10, 16 20, 25, 32. Simple square design. Switch integrated. Easy centering. Precise installation pace saving structure Overview his direct mount cylinder is a high rigidity/small square air cylinder with excellent installation accuracy and multisurface direct mount. he square shaped body improves

More information

30 Watt Wallwart Switching Adaptor. 40 Watt LED Driver. 75W Power Supply With Plug and Connector IP66 IP67. Product Details. Features.

30 Watt Wallwart Switching Adaptor. 40 Watt LED Driver. 75W Power Supply With Plug and Connector IP66 IP67. Product Details. Features. 30 Watt Wallwart witching daptor Part Number 690010.004 2.04" 0.67" 1.57" Plastic 30W Power Factor.90 100-240V 24V D, 1.25 mps Over-voltage, Over-current, Overpower & hort circuit protection 3106676 3.15"

More information

INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR FATORY SET Wiring See page 6 for other wiring configurations O W N E R S M A N U A L GH INDUSTRIAL DUTY OMMERIAL DOOR OPERATOR YEAR WARRANTY Serial # Box Installation Date NOT FOR RESIDENTIAL USE Wiring

More information

Door Lock Control RUNNER (EWD615U) From Power Source System (See Page 62) Body ECU 7. 5A GAUGE 20A DR/LCK 7. 5A ACC 10A DOME 15A IG1 DRLP

Door Lock Control RUNNER (EWD615U) From Power Source System (See Page 62) Body ECU 7. 5A GAUGE 20A DR/LCK 7. 5A ACC 10A DOME 15A IG1 DRLP Door ock ontrol From Power Source System (See Page 6) (), 5(), 6() ody EU 5 IG 0 DOME 7. 5 GUGE 0 D/K 7. 5 D DP DY SPD 8 J Y- J 7 I G - G- W 9 E V- Y W- V- G SP G- 7 I S8 Skid ontrol EU with ctuator Y-

More information

Bypass Isolation Transfer Switches Amperes

Bypass Isolation Transfer Switches Amperes upersedes A 11844 pages 1-8, dated January 1995. Technical Data Effective: March 1 Page 1 Table of Contents Page Introduction..................... 2 witch Application ection......... 2 Features, Benefits

More information

DD Motor Designation MDM. D D None 34 D NO H. DD Motor Designation. External Diameter Rated Troque Encoder Type

DD Motor Designation MDM. D D None 34 D NO H. DD Motor Designation. External Diameter Rated Troque Encoder Type Motor esignation XGT Servo System(X/XM) 90 / 91 Motor esignation MM None 34 NO H Motor Type Input Power Supply Rated Speed Shape of Shaft End : MOTOR None : 220 : 300rpm H : Hollow Type : 200rpm G : 150rpm

More information

Bettis EHO Electro-Hydraulic Operator

Bettis EHO Electro-Hydraulic Operator ettis Electro-Hydraulic Operator The ettis is a self-contained, quarter-turn, valve actuator that combines proven technologies from Emerson s ctuation Technologies. The actuator has been designed for critical

More information

EZ Meter-Pak Meter Centers

EZ Meter-Pak Meter Centers NEMA 3 onstruction Vac Maximum, for use on A systems, suitable for use as ervice Equipment. tility ompany equirements: eview local utility requirements to ensure that metering equipment meets their standards.

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

INTRODUCTION. Products CONTENTS. Circular Threaded Coupling Connectors. Reverse Bayonet Coupling Connectors

INTRODUCTION. Products CONTENTS. Circular Threaded Coupling Connectors. Reverse Bayonet Coupling Connectors IOUIO etronics India, established as manufacturers of connectors in, has grown into a leading producer and exporter of I grade electrical connectors and related accessories. etronics India's continuing

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - 6 Series 6 Series Miniature Switches and Pilot Devices Key features of the 5/8 6 Series include: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB terminal options

More information

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#2

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#2 Operators Manual SUREFIRE II Single Phase PDI - SLR (24VD, 115VA & 230VA) 36412 r#2 ontents Precautions & Symbols...2 Manufacturer s Statement...2 General...2 Features...2 Operation...3-4 Technical Data...5

More information

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This

More information

Variable Frequency AC Motor Drive Units

Variable Frequency AC Motor Drive Units 14 Variable Frequency A Motor Drive Units ulletin 2162T and 2163T PowerFlex 40 Drive................................................. 171 These combination variable frequency A motor drive units are specifically

More information

Load Capacity (inertia vs. time) 2 Stop

Load Capacity (inertia vs. time) 2 Stop Load Capaity (inertia vs. time) 2 top top 4 top top Load Inertia ( lb in 2 ) 4.8. x 14 1 Motor 5 x 14 1 Motor 4 2 1 12 9 15 x 14 2 Motor 1 Motor 4 2 1 5 x 15 2 Motor 1 Motor 1 2 1 2 1 2 1 2 8 top 1 top

More information

MODEL K B-360/-500

MODEL K B-360/-500 MODEL K79-13493B-360/-500 Logic Board Replacement Kit APPLIATI REQUIREMENTS: Model FDOB operator with charge circuit board incorporating firmware versions 06-FDOB-360 or 06-FDOB-500. FUNTI: Replacement

More information

503 Series Solenoid Pilot Actuated Valves

503 Series Solenoid Pilot Actuated Valves Solenoid Pilot ctuated Valves Offered by: Specialists in Valves, ontrols, Pneumatics, Fluid Measurement Phone: (203) 261-6711 www.okcautomation.com 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve and

More information