Accessories - Field Installable

Size: px
Start display at page:

Download "Accessories - Field Installable"

Transcription

1 Accessories - Field Installable A7 ontactors Type 1 General Purpose Enclosures ➋➌ Starters & Enclosed Products Enclosure (Box) Kit Includes: Hinged cover Backpan pre-drilled for listed arrangements (not tapped) (2) Ground Lugs and Symbol label (2) 22mm knockouts for pilot devices ➍ EP7-ERA Overload Reset Adapter MR7 Reset Kit for over (2) 22mm knockouts for Reset ➎ Dual onduit knockouts - Top and Bottom A Box - (2) 1/2 to 3/4" and (1) 3/4 to 1" B Box - (2) 1/2 to 3/4", (1) 1 to 1-1/4", (1) 3/4 to 1" (4) 8-32 x 1/2" screws for mounting controllers B Box also includes (2) x 3/4" screws Does not include wire A Box Kit B Box Kit atalog Number Price atalog Number Price M A 116 M B 145 Optional: 35mm DIN Rail Kit with (2) x 1/4 screws ➋ SF-2 (2 inches long) 8 SF-3 (3 inches long) 10 Dimensions ➏ 10 x 8 x 6 Type 1 Enclosure 12 x 10 x 6 Type 1 Enclosure For use with overload A Box Kit accommodates B Box Kit accommodates For use with ontroller EP7-ED1* EP7-EE* T7N Use with Use with Space for Use with Use with Use with Space for No PT 50VA PT ➌ 2" DIN Rail ➋ No PT 50VA PT 100VA PT ➌ 3" DIN Rail ➋ Non-reversing ontactors A ~ ~ ~ A ➐ ~ ~ ~ No No No N/A Reversing ontactors AU ~ ~ ~ No AU ~ ~ ~ No No No AU ➐ ~ ~ ~ No No No No N/A No No Non-Reversing Starters AT ➊ AT ➊ AT ➐ N/A ➊ No No No N/A Reversing Starters AUT ➊ No AUT ➊ No AUT ➊ No No No AUT ➐ N/A No No No No No No No No No NEMA Sized Non-reversing Starters ATN ➊ ATN7-37 ➊ ATN7-43 ➊ ATN7-85 N/A ➊ No No No N/A ➊ Alternatively T7N overload relay can be used which will require T7N-RA3 Reset Adapter. Not included in the kit. Order separately. ➋ 2 DIN rail can accommodate up to (3) V7-W4 TB s or equivalent DIN rail mount timers, relays, etc. Order kit SF-2 separately. 3 DIN rail can accommodate up to (6) V7-W4 TB s or equivalent DIN rail mount timers, relays, etc. Order kit SF-3 separately. ➌ Enclosure designed for use with PT with top mount secondary fuse, plus back pan mounted Ambus Fuseholder with (2) primary fuses. A PT and the addition of extra terminal blocks or other control relay using the 2 DIN rail space may require a design change. ➍ This enclosure is designed for use with a D7 multi-function Start/Stop as standard plus a D7D monolithic pilot light to fit the (2) 22mm knockouts provided. Additional pilot device holes will require field drilling and may interfere with the controller or the addition of a PT or TB s. ➎ (2) 22mm knockout locations are provided for one reset Kit to be located contingent on the type of controller used. See box Instruction sheet for mounting details of controller and reset kit. ➏ For enclosure dimensions see page 122 ➐ A7-97 and AT7-97 will not fit in B Box because of wire bending space requirements. See Selection tables for box sizes starting on page 122 for dimensions. 102 Discount Schedule B7

2 Accessories Field Installable Enclosure Pilot Device Kits & Ratings Definitions Pilot Device Kits All applications (except Kwikstarters and Explosion Proof enclosures) ➊ Kits ontact Blocks included Description NO N Multi-Function Pushbutton kit ➋ START-STOP 1 1 Non-illuminated, Standard for A and B Box Kits. Multi-Function Pushbutton kit ➋ FORWARD-STOP-REVERSE 2 3 Non-illuminated, Standard for A and B Box Kits. STOP and START Two button pushbutton kit 1 1 FORWARD, REVERSE and STOP Three button pushbutton kit HAND-OFF-AUTO selector switch kit Name plate included. FWD-OFF-REV selector switch kit Name plate included. OFF-ON selector switch kit Name plate included. Monolithic Pilot Light kit LED Lamp and lens cap Does not include nameplate ~ For Use With Enclosure... atalog Number Price Type 1, 12, 3R, 4, 4X, 13 SS6-D7P 53 Type 1, 12, 3R, 4, 13 SS6-D7M 56 Type 1, 12, 3R, 4, 4X, 13 SS5-D7P 100 Type 1, 12, 3R, 4, 13 SS5-D7M 105 Type 1, 12, 3R, 4, 4X, 13 SS1-D7P 62 Type 1, 12, 3R, 4, 13 SS1-D7M 66 Type 1, 12, 3R, 4, 4X, 13 SS7-D7P 115 Type 1, 12, 3R, 4, 13 SS7-D7M 121 Type 1, 12, 3R, 4, 4X, 13 SS2-D7P 52 Type 1, 12, 3R, 4, 13 SS2-D7M 54 Type 1, 12, 3R, 4, 4X, 13 SS9-D7P 52 Type 1, 12, 3R, 4, 13 SS9-D7M 54 Type 1, 12, 3R, 4, 4X, 13 SS4-D7P 40 Type 1, 12, 3R, 4, 13 SS4-D7M 42 Type 1, 12, 3R, 4, 4X Replace with color choice R = Red G = Green SS8-D7D- V SS8-D7D- V SS8-D7D- 0V 36 Starters & Enclosed Products Example of pushbutton kits on an A Box ➊ Pilot Device Kits do not include control wires. See instruction sheet for installation. ➋ Multi-function START/STOP pushbutton are standard for General Purpose Type 1(M1) dimensions A and B enclosures. Discount Schedule B7 103

3 Starter Modification odes A.. oil odes & Voltage Ranges ➊➎ All catalog numbers, list prices and enclosure dimensions in the previous section reflect contactors with A coils. If necessary, add the appropriate price adder to the list price for each coil required as shown in the online catalog. Remember that reversing applications require two coils. Price Adder x 2. A.. oil odes (Replace Q in cat.# with coil code) A7-9 thru A7-97 AN Hz 60 Hz Z V V 110 ~ ~ 110V V B ~ ~ 208 ~ 208V 208W ~ ~ 220W ➋ V 208-0V 0 220V 0V 0B ~ ~ 0W ~ ~ 277 0V 277V V 440V 440W ~ ~ 460W ~ ~ V 480V 575 ~ ~ V 600V Price Adder ~ ~ A / D oil odes & -EI oil Upgrade Adders All ontactor and Starter onfigurations D.. oil odes & Voltage Ranges ➊➎ For starters with D coils, select oil ode from the table below. Remember that reversing applications require two coils (Price Adder x 2). Starter catalog numbers must be modified when using D coils. For example: For AT contactors, add an E to catalog number for Electronic D oils. i.e.: AT7-9 becomes AT7-9E For AT contactors, add a D to catalog number. i.e.: AT7-60 becomes AT7-60D D.. oil odes (Replace Q in cat.# with coil code) ➏ ➏ ➍ A7-9E..37E AN7-12E 37E A7-43E 55E AN7-43E A7-60D...97D AN7-85D A7 ode Voltage Voltage Voltage 12E 12VDE 12VDE ~ E VDE VDE ~ DD ~ ~ VD 36E 36-48VDE 36-48VDE ~ 48E 48-72VDE 48-72VDE ~ 48DD ~ ~ 48VD 110E 110VDE 110VDE ~ 110DD ~ ~ 110VD ~ ~ ~ ~ 125DD ~ ~ 125VD 220E 220VDE 220VDE ~ 220DD ~ ~ 220VD 250DD ~ ~ 250VD Price Adder ➎ AT9 A/D oil odes and Voltage Ranges ➋➌➎ Electronic oils V -60V V V V Price Adder for (Replace Q in cat.# with coil code) PL option A A/D W 48W W 480W ~ A9-116-EI 370-EI ~ ~ W 480W 50 A9-400-EI 750-EI W ➐ 48W W 480W ~ A9-860-EI 1060-EI A/D with PL Input ~ ~ W ~ ~ A EI W ➐ 48W W 480W ~ A EI 2650-EI ~ ~ W ~ ~ ➊ Only the most common coils are shown here. Other coil voltages may be available. Refer to ontactor Renewal Parts in Section A of this catalog, or contact your nearest Sprecher + Schuh sales office. ➋ Wide range coil. ➌ -EI designates contactor coil with PL input. Selections A with EI requires use of control logic on terminals 1, 2, 3. A9-400 contactors and larger include an integral switch to select use of EI. ➍ DD coils are standard for A7-60D...97D. ➎ Reversing applications require two coils. Add appropriate price adder(s) to list price of enclosed contactors and starters. Remember to add price for each coil required. ➏ A7-9E...55E electronic coils are not interchangeable with non-electronic D or A coils. ➐ This coil range is -60V D only. 104

4 A7 ontactor with EP7 Overload Relay ➊➌➍ For use with contactor... Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay) Price Adder 3-Phase / Manual Reset / lass D1AB EP7-ED1AB Standard A7-9...A D1BB EP7-ED1BB Standard D1B EP7-ED1B Standard D1DB EP7-ED1DB Standard D1EB EP7-ED1EB Standard D1D EP7-ED1D Standard A A D1DD EP7-ED1DD Standard D1ED EP7-ED1ED Standard 9 45 D1FD EP7-ED1FD Standard 3-Phase / Auto or Manual / Adjustable Trip lass 10, 15, 20 & EAB EP7-EEAB 17 A7-9...A EBB EP7-EEBB EB EP7-EEB EDB EP7-EEDB EEB EP7-EEEB ED EP7-EED 21 A A EDD EP7-EEDD EED EP7-EEED EFD EP7-EEFD 21 A EQD EP7-EEQD Standard EEE EP7-EEEE Standard A A EFE EP7-EEFE Standard EGE EP7-EEGE Standard EVE EP7-EEVE Standard B7 ontactor with EP7 Overload Relay EP7 Second Generation Overload Relay odes Series AT7 and AT6 Starters Large Amp EP7 Solid State Overload Relays, Automatic or Manual Adjustable Trip lass ➊➋➌➍ Directly Mounts to ontactor ➋ Adj. Range (A) Overload Relay ode ( ) T Ratio atalog Number (of Overload Relay) Automatic or Manual Reset for 3-Phase Applications Adjustable Trip lass 10, 15, 20 & 30 Price Adder A EHJ 150:5 EP7-EEHJ Standard A EJJ 200:5 EP7-EEJJ Standard A T3 300:5 ➎ Standard A T6 600:5 ➎ Standard A ~ Refer to Factory Standard Special Notes: Wye-Delta Starters - First multiply motor full load current by 58%. Then, using this figure, select appropriate Overload Relay ode from tables above. Part Winding Starters - First multiply motor full load current by 50%. Then, using this figure, select appropriate Overload Relay ode from tables above. Variable Frequency Drives - EP7 solid state overload relays cannot be utilized on VFDs or Softstarters with Braking option. Starter Modification odes For use with contactor... Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay) Price Adder 1-Phase / Automatic or Manual Reset / lass 10 A7-9...A EPB EP7S-EEPB Standard ERB EP7S-EERB Standard ESB EP7S-EESB Standard A7-30..A ETD EP7S-EETD Standard A A EUE EP7S-EEUE Standard This item is available in the ORANGE E PRESS 3-day shipping program ➊ 3-phase EP7 units are only designed for 3 applications. Single phase EP7S units are only designed for 1 applications. ➋ This reference is not intended to be a guide for selecting contactors. Size overload relays using the full load current of the motor. ➌ The reset time of a EP7 set in the automatic mode is approximately 180 seconds. ➍ EP7 Overload relays do not work with Variable Frequency Drives or any Sprecher + Schuh Softstarter with braking options. ➎ Utilizes UL approved urrent Transformers and a EP7-EEB overload relay. Refer to page B13 for current setting guidance. For E approved urrent Transformers refer to factory. 105

5 Thermal Overload Relay odes Kits and T7N on Series AT7 Starters Starter Modification odes Intelli-button Reset Kit Factory Modification The Intelli-button plus your choice of side-mounted module can be orderd as a factory modification, installed in any control panel built by Sprecher + Schuh that contains a EP7-EE_ overload relay. Just add the kit suffix shown below to the end of the starter catalog number. For example, AT7-9--EEB-G0 becomes AT7-9--EEB-G0-IB2 + Side Mount Module... Remote Reset Only Jam and Remote Reset Thermistor Relay and Remote Reset Ground Fault and Remote Reset Ground Fault and Jam and Remote Reset Module Add to end of atalog Number -IB1 -IB2 -IB3 -IB4 -IB5 -IB6 -IB7 -IB8 -IB9 -IB10 -IB11 Kit includes... EP7-ERR EP7-EJM (B) EP7-EPT EP7-EGF EP7-BT1 (45A) EP7-EGF EP7-BT2 (90A) EP7-EGF EP7-BT3 (180A) EP7-EGF EP7-BT4 (420A) EP7-EGJ EP7-BT1 (45A) EP7-EGJ EP7-BT2 (90A) EP7-EGJ EP7-BT3 (180A) EP7-EGJ EP7-BT4 (420A) Price Adder A7 Starters with optional T7N Bimetallic Overload Relay ➊ Directly Mounts to ontactor... A7-9 A7-23 Frame A A7-30 A7-37 Frame B A Frame A7-60 A7-97 Frame D Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) AA16 T7N-23-A AA25 T7N-23-A AA40 T7N-23-A AA50 T7N-23-A AA63 T7N-23-A AA80 T7N-23-A AB10 T7N-23-B AB13 T7N-23-B AB16 T7N-23-B AB20 T7N-23-B AB25 T7N-23-B AB32 T7N-23-B AB40 T7N-23-B AB48 T7N-23-B AB63 T7N-23-B AB75 T7N-23-B A10 T7N A12 T7N A16 T7N A20 T7N A21 T7N A25 T7N B20 T7N B21 T7N B25 T7N B30 T7N B36 T7N B38 T7N T7N T7N T7N T7N D47 T7N D60 T7N D75 T7N D90 T7N D97 T7N Price Adder This item is available in the ORANGE E PRESS 3-day shipping program Special Notes: Wye-Delta Starters - First multiply motor full load current by 58%. Then, using this figure, select appropriate Overload Relay ode from tables above. Part Winding Starters - First multiply motor full load current by 50%. Then, using this figure, select appropriate Overload Relay ode from tables above. ➊ Separately mounted overload is available. See Section B. 106

6 Modifications Factory Assembled Enclosure Type Reversing Multi- Speed Modifications or Special Feature ➋ hange Last Digit (0) in atalog Number To: Pilot Devices In over or Flange Type 1 General Purpose Type 3R/4/4X/12 Type 7/9 Explosion Proof Start-Stop Pushbutton 3 On-Off Pushbutton Emergency Stop Pushbutton - Twist to Release ➌ 9 Hand-Auto Selector Switch 5 Off-On Selector Switch Hand-Off-Auto Selector Switch 7 Pilot Light Only ➊ Pilot Lights Only (2) ➊ Pilot light w/ Start-Stop Pushbutton ➊ 13 Pilot Light w/ On-Off Pushbutton ➊ Pilot Light w/ Hand-Auto Selector Switch ➊ 15 Pilot Light w/ Off-On Selector Switch ➊ Pilot Light w/ Hand-Off-Auto Selector Switch ➊ 17 For-Stop-Rev - Pushbutton 3 Up-Stop-Down Pushbutton 4 -Stop-lose Pushbutton High-Stop-Low Pushbutton 3 Fast-Stop-Slow Pushbutton 4 Reversing Multi- Speed Reversing Multi- Speed Reversing Multi- Speed For-Off-Rev Selector Switch 6 Up-Off-Down Selector Switch 7 -Off-lose Selector Switch 8 High-Off-Low Selector Switch 5 Fast-Off-Slow Selector Switch 6 Pilot Lights (2) w/ For-Stop-Rev Pushbutton ➊ 23 Pilot Lights (2) w/ Up-Stop-Down Pushbutton ➊ Pilot Lights (2) w/ -Stop-lose Pushbutton ➊ 25 Pilot Lights (2) w/ High-Stop-Low Pushbutton ➊ 23 Pilot Lights (2) w/ Fast-Stop-Slow Pushbutton ➊ Pilot Lights (2) w/ For-Off-Rev Selector Switch ➊ 26 Pilot Lights (2) w/ Up-Off-Down Selector Switch ➊ 27 Pilot Lights (2) w/ -Off-lose Selector Switch ➊ 28 Pilot Lights (2) w/ High-Off-Low Selector Switch ➊ 25 Pilot Lights (2) w/ Fast-Off-Slow Selector Switch ➊ Factory Modifications This item is available in the ORANGE E PRESS 3-day shipping program Ordering Instructions hange base atalog Number according to instructions at top of column 2. Example: To Add a Start-Stop Pushbutton: change AT GO to AT G3 ➊ Pilot Lights may be applied with VA/D, VA or 0VA control circuit. Pilot Lights with 380 VA...575VA require a control circuit transformer. ➋ Modifications may change dimension of starter enclosure. ➌ Emergency Stop pushbutton includes inscription ring D7-15YSE112. For other selections from page H68 refer to factory. 107

7 Modifications Factory Assembled ontroller Series and Price Addition Factory Modifications 1 N.O. 1 N.. 1 N.O. & 1 N.. 2 N.O. 2 N.. 1 NO + 2 N Auxiliary 2 NO + 1 N Auxiliary 3 NO Auxiliaries 3 N Auxiliaries 2 N.O. & 2 N.. 1 NO + 3 N Auxiliary 3 NO + 1 N Auxiliary 4 NO Auxiliaries 4 N Auxiliaries Modifications or Special Feature ➎ Alternate Auxiliary ontact Arrangements 1 N.. in lieu of standard 1 N.O. (on AT7) 2 N.. in lieu of standard 2 N.O. (on AUT7) Standard apacity ➌ Primary Volts ADD Suffix to atalog Number Additional Auxiliary ontacts ➏ L10 L01 L11 L20 L02 L12 L21 L30 L03 L22 L13 L31 L40 L04 Enclosure Type A7-9 to 55 LX1 LX2 All N/ 7 ontrol ircuit Transformer (with fused primary & secondary) Replace ( ) in catalog # Secondary Volts 110 with following codes ➋➍ XA XB X XD XG XE XF XJ XK XO XP XY 208 XA05 0 XB05 50 Watt 480 X05 Extra apacity 600 XD05 0 XE XF XA1 0 XB1 480 X1 600 XD1 100 Watt Extra apacity 0 XE1 480 XF1 600 XJ1 Special Voltage Transformer - Add suffix F/A to end of catalog # ➊ For applications requiring more than 100 Watt extra capacity A7-60 to 97 A9-116(-EI) to A9-146(-EI) A9-190(-EI) to A9-370(-EI) A9-400-EI to A9-750-EI A9-860-EI to A EI All ~ ~ ~ ~ All All All Type 1, 12, 3R, 4,4X N/ Type 7/ ~ Type 1, 12, 3R, 4,4X ~ ~ ~ ~ Type 7/ ~ ~ ~ ~ Type 1, 12, 3R, 4,4X Type 7/ ~ All, Refer to Factory Refer to Factory Ordering Instructions hange base atalog Number according to instructions in column 2. Example: To Add a ontrol ircuit Transformer (480/) and additional NO/ N auxiliaries: change AT GO to AT7-30-X- -G0-L11. Note: Separate multiple modification suffixes with a hyphen (-). ➊ Factory assigned. ➋ oil will be factory selected based on transformer secondary. ➌ See page 112 for detail specifications for ontrol ircuit Transformer. ➍ Refer to factory for pricing on larger oversized control circuit transformer selections. ➎ Modifications may change dimension of starter enclosure. ➏ Auxiliary addition is per contactor. Quantity is double for reversing applications. Double price adder accordingly. 108

8 Modifications Factory Assembled Modifications or Special Feature ➋ Rating (W) Power Supply Output Amps Input V A Output V 60º Replace ( ) in catalog # with following codes Enclosure Type ontroller Series and Price Addition A to D Output Power Supplies 1-Phase Standard apacity (A7-9E 55E) Power Supply (with no PT) PS1P 355 Power Supply (with no PT) PS1E 355 Power Supply 208 VA Primary PS1XA 665 All Power Supply 230 VA Primary PS1XB Power Supply 460 VA Primary PS1X 665 ~ ➊ Power Supply 575 VA Primary PS1XD Phase Standard apacity (A7-60D 97D) Power Supply (with no PT) PS4P 599 Power Supply (with no PT) PS4E 599 Power Supply 208 VA Primary PS4XA 1006 All ~ Power Supply 230 VA Primary PS4XB Power Supply 460 VA Primary PS4X 1006 ➊ Power Supply 575 VA Primary PS4XD Phase 90W Extra apacity (A7-9E 55E) Power Supply (with no PT) PS2P 414 Power Supply (with no PT) PS2E 414 Power Supply 208 VA Primary PS2XA 7 All Power Supply 230 VA Primary PS2XB Power Supply 460 VA Primary PS2X 7 ~ ➊ Power Supply 575 VA Primary PS2XD 7 2-Phase Standard apacity (A7-9E 55E) Power 230 VA Primary PS6B 441 All Power 460 VA Primary PS6 441 ~ ➊ 2-Phase Standard apacity (A7-60D 97D) Power 230 VA Primary PS7B 633 All ~ Power 460 VA Primary PS7 633 ➊ For applications requiring extra capacity on either device, please refer to factory Refer to Factory RI7E- Electronic Interface Module for use with A7-9 A7-97: Interface between the D control signal from a PL and the A operating mechanism of the contactor. Eliminates the need for a power supply-current draw is 10 to 15 ma across a voltage range of 12-48V D Requires no additional surge suppression for the coils Must have output voltage 110 0V A Add Suffix to end of catalog number: for example change AT GO to AT GO-JE add Suffix to end of atalog Number -JE All A7-9E to A7-55E A7-60D to A7-97D A9-116 to A ➊ ➊ Factory Modifications Ordering Instructions Replace in base atalog Number with Power Supply code. Example: To Add a Standard apacity Power Supply with ontrol ircuit Transformer (480/): change AT7-30E- - -GO to AT7-30E-PS1X- -G0. ➊ Not applicable for Series A9 Starters. AT9 Starter applications should strongly consider the use of the EI functionality included in the A EI ontactors. The optional electronic interface selection allows the A9 contactor to be switched from a PL or other low-level signal source (15 33V D) without the need of an interposing relay. The current burden of the interface is 15 ma maximum. ➋ Modifications may change dimension of starter enclosure. 109

9 Modifications Factory Assembled ontroller Series and Price Addition Factory Modifications Modifications or Special Feature ➐ ADD Suffix to atalog Number Enclosure Type Other modifications Fused ontrol ircuit for separate or common control ➏ - 1 Fuse F1 All, Fuses F2 All, Surge Suppressor - R Link R All, Surge Suppressor - Varistor RV All, Surge Suppressor - Diode RD All, 41 ~ Unwired Terminal Blocks Specify quantity ( ). - TB All 21 x ontrol Relay Limited to one per controller-8 pole maximum, Specify F/A ➊ All, 535 pole arrangement and voltage ➎ Timing Relay Limited to one per controller-specify On or Off delay. F/A ➊ All, 714 Voltage will be same as coil voltage ompelling Relay ➋ ➎ F/A ➊ All, 560 Progressive or Decelerating Relay ➋ ➎ F/A ➊ All, 1297 Omit Automatic Alternator ➌ F/A ➊ All, -487 Back Spin Timer ➍ F/A ➊ All, 649 Program Timer ( hour) ➍ F/A ➊ All, 689 Fireman Damper ontrol Option Non-ombination Fusible Non-Fusible HVA Enclosed Starter Fireman Damper Option Thermal Magnetic VA/D FD - VA/D FD Non-ombination Refer to Factory Fusible Non-Fusible Thermal Magnetic Type 1 Type 3R A7-9 to 55 A7-60 to 97 A9-116(-EI) to A9-146(-EI) A9-190(-EI) to A9-370(-EI) A9-400-EI to A9-750-EI A9-860-EI to A EI Ordering Instructions hange base catalog number according to instructions at top of column 2 or 3. Example: To Add a Start-Stop Pushbutton, ontrol ircuit Transformer (480/) and R Link: change AT GO to AT7-30-X- -G3-R. Note: Separate multiple modification suffixes with a hyphen (-). ➊ Factory assigned. ➋ For Multi-speed controllers. ➌ For Duplex Pump controllers. ➍ For Pump Panel controllers. ➎ If controller has a ontrol ircuit Transformer, select transformer with additional capacity for relay required. ➏ PT and power supply modification includes fused control circuit protection. ➐ Modifications may change dimension of starter enclosure. 110

10 Modifications Factory Assembled ontroller Series and Price Addition Modifications or Special Feature ➌ ADD Suffix to atalog Number Enclosure Type A7-9 to 55 A7-60 to 97 A9-116(-EI) to A9-146(-EI) A9-190(-EI) to A9-370(-EI) Meters Ammeter - Single Phase Ammeter - Three Phase (includes switch) AM1 AM3 Voltmeter - Single Phase VM1 Voltmeter - Three Phase (includes switch) VM3 All, Refer to factory Wattmeter Elapsed Time Meter WM ETM Enclosures Space Heater (with N.. interlock) HTR Type 1, 12, 3R, 4, 4X 591 Breather and Drain BD Type 7/9 146 Service Identification Nameplate F/A ➊ All 33 Miscellaneous Lightning Arrester ➋ LA 347 Surge apacitor ➋ S All, 4 Phase Monitor Relay F/A ➊ 487 UL508A Panel Label UL Type 1, 12, 3R, 4, 4X 50 UL3 Panel Label (includes 508A) ULX Type 7/9 Refer to factory A9-400-EI to A9-750-EI A9-860-EI to A EI Factory Modifications Panel Shop ertifications Sprecher + Schuh is an ISO9001 company. Our panel shops are UL and ATEX ertified. Please refer to factory for specifications and label options for the following panel certifications. UL508A or SUSE label: Most starter assemblies can be supplied with a UL508A Industrial ontrol Panel label. ombination starters can be supplied with Suitable for Service Entrance (SUSE) label. The need for a UL508A or SUSE label must be identified at the time of quotation as well as on the purchase order. The need for a UL508A label may not change the components we would normally use but we must consider all possible requirements at the time we are developing the bill-of-material to be referenced at the time of order entry. Failure to identify the need for a UL508A label or SUSE label at the time of quotation may result in change notice price adders. ATEX ertification: A requirement for ATEX certification MUST be identified at the time of quotation as well as on the purchase order. ATEX certification of a Type 7/9 explosion proof enclosure definitely requires all conduit and cover openings to be drilled by the enclosure manufacturer. Further, all pilot devices and equipment to be installed must be identified as it controls the heat dissipation which is an ATEX certification requirement. Absolutely no field modification of an ATEX certified starter assembly is allowed. Failure to identify the need for an ATEX certification at the time of quotation and order entry may result in 100% cancelation or re-stocking charge since a new enclosure will be required. UL3 ertification: The UL3 label for explosion proof starters and panels encompasses the UL508A certification. This means all components in a UL3 labeled panel must first comply with UL508A, and all components in the panel must have a UL label in some form, including the wiring. A special name plate and UL508A label are applied to the panel or starter. A panel is not UL3 certified unless both label and name plate are present. ontact customquotes@sprecherschuh.com for more information on UL3 certified panels. Ordering Instructions hange base catalog number according to instructions at top of column 2. Example: To add an Elapsed Time Meter and Breather Drain to an explosion-proof starter, change AT E0 to AT E0-ETM-BD. Note: Separate multiple modification suffixes with a hyphen (-). ➊ Factory assigned. ➋ For Pump Panel controllers. ➌ Modifications may change dimension of starter enclosure. 111

Starters + Enclosed Product

Starters + Enclosed Product Starters + Enclosed Product General Description... 2 atalog Number oding... 4 Enclosure Ratings... 6 The Orange Express Program... 8 ustom ontrol Panels... 10 Fractional Manual Starters... 12 KWIKstarters...

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

Series CA7 Contactors

Series CA7 Contactors Series CA7 Contactors Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 75HP @ 46V Over years of design experience has produced Sprecher + Schuh s seventh generation

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as

More information

Technical Information

Technical Information Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts C7 3-Pole Contactors C7-2 C7-6 C7-23

More information

Orange Express Selection Guide Table of Contents

Orange Express Selection Guide Table of Contents Orange Express Selection Guide Table of Contents General escription...2 KWKstarters...4 KWKstarters...6 KWKstarters Enclosure imensions...8 FVNR CA7 Contactors, Enclosed...10 FVR CA7 Contactors, Enclosed...11

More information

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940 Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Overload Relays. Overload Relays. CEP9 Electronic Overload Relays... B27 Technical Information & Dimensions (Online)... B34

Overload Relays. Overload Relays. CEP9 Electronic Overload Relays... B27 Technical Information & Dimensions (Online)... B34 Overload Relays CEP7 Solid State Overload Relays... 2 Manual & Automatic Reset... 5 Larger Amp Manual & Automatic Reset... 7 Accessories... 8 Technical Information & Dimensions (Online)... 12 CEP9 Electronic

More information

Motor Protection OLR. CEP7 Second Generation Solid State Overload Relays... B2 Technical Information... B8

Motor Protection OLR. CEP7 Second Generation Solid State Overload Relays... B2 Technical Information... B8 Second Generation Solid State Overload Relays... 2 Technical Information... 8 CT7 Thermal Overload Relays... 17 Technical Information... 20 CT7K & CT4 Thermal Overload Relays... 25 Technical Information...

More information

E C N A A F -

E C N A A F - 33-52 NA ontactors & Starters 3-Phase agnetic Starters nclosed Freedom Line January 1 Vol. 2, Ref. No. [0068] Selection Table 33-102. NA Freedom Line nclosed ontrol ing System 33 esign Page N - NA 33-40

More information

[V] Common Control Transformer Control (See page 1-78 Note)

[V] Common Control Transformer Control (See page 1-78 Note) Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state

More information

onlinecomponents.com

onlinecomponents.com Second Generation Solid State Overload Relays... 2 Technical Information... 8 CT7 Thermal Overload Relays... 17 Technical Information... 20 CT7K & CT4 Thermal Overload Relays... 25 Technical Information...

More information

Overload Relays. CEP7 Solid State Overload Relays... B2 Manual & Automatic Reset... B5 Larger Amp Manual & Automatic Reset... B7

Overload Relays. CEP7 Solid State Overload Relays... B2 Manual & Automatic Reset... B5 Larger Amp Manual & Automatic Reset... B7 Overload Relays Overload Relays CEP7 Solid State Overload Relays... 2 Manual & Automatic Reset... 5 Larger Amp Manual & Automatic Reset... 7 Accessories... 8 Technical Information... 12 Dimensions... 19

More information

CEP7-E Electronic motor protection relays

CEP7-E Electronic motor protection relays CEP7-E Electronic motor protection relays Motor protection with leading edge technology, expandable protection and communication. MOTOR CONTROL AND DRVES NHP Electrical Engineering Products AUS NZ 3 NHP

More information

Softstarters Type PSR. Softstarters

Softstarters Type PSR. Softstarters Type PSR Type PSR Type PSR General information Designed for motor currents from 3 to 45 A, PSR complement the existing advanced PST for 30-1050 A and the flexible PSS for 30-1050 A. The PSR Softstarter

More information

Motor Protection relays

Motor Protection relays Motor Protection relays Overload and Contactor selection chart - Motor protection/ overload types - 4 CT 8 thermal overload relay to suit CA8 contactors - 5 CT 7N thermal overload relays to suit CA 7 contactors

More information

Sprecher + Schuh s broad line of IEC/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures

Sprecher + Schuh s broad line of IEC/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures Enclosed ontactors Sprecher + Schuh s popular contactor lines housed in a variety of enclosures Sprecher + Schuh s broad line of E/UL HP rated contactors can be purchased pre-installed in a variety of

More information

Enclosed Starter Selection Guide. Featuring Snap-together Wiring Technology

Enclosed Starter Selection Guide. Featuring Snap-together Wiring Technology Enclosed Starter Selection Guide Featuring Snap-together Wiring Technology Enclosed Starter Wiring Made Easy How It Works Component wiring is color-coded by function. The wiring sleeve cover corresponds

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors Selection ompact Definite Purpose Motor ontrol TLOG SELETION Definite Purpose ing System 2 D N 2 Model = ontactor = Three-Phase Starter = Single-Phase Starter Type 2 = Non-Reversing 27 = Non-Reversing

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

EIC combination motor starters

EIC combination motor starters pplications: Harsh and hazardous motor control environments, including refineries, chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining cross-the-line starting

More information

Sprecher + Schuh DON'T SEE IT LISTED? CONTACT OUR SALES DEPARTMENT. *updated 02/03/16

Sprecher + Schuh DON'T SEE IT LISTED? CONTACT OUR SALES DEPARTMENT. *updated 02/03/16 Sprecher + Schuh The following items are in stock and can be shipped from our warehouse within 24 hours. To order, or for additional information, please contact our Sales Department at 1-800-821-5091.

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

Series CA6 Contactors

Series CA6 Contactors Series CA6 Contactors The modern contactor for demanding applications from 75 to 600HP (@460V) - 00 to 700HP (@ 575V) Sprecher + Schuh s CA6 contactor line combines the simple function of our popular CA7

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information

Standard Materials Bodies and covers: copper-free aluminum.

Standard Materials Bodies and covers: copper-free aluminum. -26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and

More information

Technical Information

Technical Information Technical nformation - Second Generation Solid State Overload Relays Technical nformation -ED1... -EE... -EE...D Rated nsulation Voltage - U [V] 69 C Rated nsulation Strength- U imp [kv] 6 C Rated Operation

More information

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Variable Frequency AC Motor Drive Units

Variable Frequency AC Motor Drive Units 14 Variable Frequency A Motor Drive Units ulletin 2162T and 2163T PowerFlex 40 Drive................................................. 171 These combination variable frequency A motor drive units are specifically

More information

150 C 30 F B D 8L 152H C 30 F BD 43 8L

150 C 30 F B D 8L 152H C 30 F BD 43 8L SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number ode Solid-State ontroller b ontroller Type ode SM- c Ampere s ode A A A A A A A A A A

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Type E/F Simplex & Duplex Pump Controllers

Type E/F Simplex & Duplex Pump Controllers Type E/ Simplex & Duplex Pump Controllers Simplex Pump Controllers A single KTA7 motor controller plus matching CA7 contactor can be combined in an enclosure as a Simplex Combination Controller for pumping

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types Across the line starters & enclosed A9 AF750 Across the line Description A9 AF750 Maximum UL horsepower ratings UL508A Panel Program, #E105450 NEMA s (00 7) available Compact space-saving design Standard

More information

EBMC Combination Line Starters and Enclosures

EBMC Combination Line Starters and Enclosures EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors .2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

L2 FWD REV L1 L2 L1 L2 L3 FWD REV (L.H. UNIT) (R.H. UNIT) HIGH LOW HIGH LOW

L2 FWD REV L1 L2 L1 L2 L3 FWD REV (L.H. UNIT) (R.H. UNIT) HIGH LOW HIGH LOW Manual ontrol lass - RV, SMF, MMS 0/0/ lass - RV Signaling ontact for lass - RV Typical lass SMF RV9-M Typical MMS Reversing Manual Starter and Manual Motor Starting Switches -Speed Manual Motor Starting

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

CEP7 Solid State Overload Relays

CEP7 Solid State Overload Relays CEP7 Solid State Overload Relays Advanced solid state motor protection The introduction of the second generation of CEP7 solid state overload relays advances Sprecher + Schuh s leading edge technology

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16DN0 NM Size 1 Starter.1 Freedom Series Product Overview........................................ Features, enefits and Functions............................ Standards and

More information

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up Master atalog 125 s and ontactors Section R Product Bulletin R1000 Issue Date 0493 R1000 Series s The R1000 Series s switch line voltage devices from low voltage controllers. Plug-in DPDT relays and snap-in

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

Second Generation CEP7 Solid State Overload Relays

Second Generation CEP7 Solid State Overload Relays Second Generation Solid State Overload Relays Advanced solid state motor protection The introduction of the second generation of solid state overload relays advances Sprecher + Schuh s leading edge technology

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION Instruction Bulletin Bulletin No. 0006-39-03 May 997 Raleigh, NC, USA Enclosed ALTISTART 6 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION This bulletin is a supplement to

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th NM ontactors and Starters NM N16N0 NM Size 1 Starter.1 Product Overview.............................................. Features, enefits and Functions.................................. Standards and ertifications......................................

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16N0 NM Size 1 Starter NM Size 1 ontactor.1 Product Overview.............................................. 242 Features, enefits and Functions..................................

More information

CEP7-E ELECTRONIC MOTOR PROTECTION RELAYS

CEP7-E ELECTRONIC MOTOR PROTECTION RELAYS CEP7-E ELECTRONC MOTOR PROTECTON RELAYS MOTOR PROTECTON WTH LEADNG EDGE TECHNOLOGY, EXPANDABLE PROTECTON AND COMMUNCATON. MOTOR CONTROL Sales 3 NHP NHP nhp.com.au The new CEP 7 overloads now boast a formidable

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

Junction boxes for control, monitoring and control panel Ex tb

Junction boxes for control, monitoring and control panel Ex tb Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable

More information

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1... 100HP 400HP 700HP 1000HP 1400HP PCS Softstarter Controller IN-rail mountable microprocessor controller for 3-phase motors up to 480A (3...85A din-rail mountable) Provides three different starting modes

More information

Pump Panels Type 3R Enclosure

Pump Panels Type 3R Enclosure Type R Enclosure Product Family Overview June 6 Product escription The utler-hammer Pump ontrollers from Eaton s electrical business are combination starters with accessories and modifications designed

More information

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters Motors Automation Energy Transmission & Distribution Coatings GPH2 Combination Soft Starters GPH2 Combination Soft Starter 5to 350 HP The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches es Series es... 2 Assemblies... 11 s... 15 Accessories... 25 Technical Information... 26 Dimensions... 31 Series R-Line es... 34 s... 39 Accessories... 40 Technical Information... 41 Dimensions... 42 es

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information

NEMA Vacuum Break Contactors and Starters

NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Starter.1 Product Description....................................... Application Description.................................... Operation...............................................

More information

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum . Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor circuit 5 =

More information

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK PART 1 - GENERAL 1.1 GENERAL: SECTION 15150 MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK A. The Mechanical Contractor shall furnish to the Electrical Contractor for installation,

More information

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of

More information

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494] 7-2 Lighting ontactors Open ontrol June 2005 N5 lectrically Held Vol. 2, Ref. No. [09] ontents eatures Instructional Leaflets 7 escription Page lectrically Held Product escription....... 7-2 pplication

More information

NEMA Space Saving Contactors and Starters

NEMA Space Saving Contactors and Starters Technical Data NEMA Space Saving Contactors and Starters Bulletin Numbers 300, 300S, 305, 309 Topic Page Summary of Changes 1 Product Description 2 Product Selection 3 Accessories (NEMA Sizes 0 3) 7 Accessories

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

STAINLESS STEEL PANEL MOUNT

STAINLESS STEEL PANEL MOUNT Z A H LO C STAINLESS STEEL PANEL MOUNT Optional Legend Plate Cover Screw Retaining Washer Panel Mount Bracket Explosion Protective LED Pilot Light Stainless Steel Washer Actuator Spacer Locknut Explosion

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information