Sprecher + Schuh s broad line of IEC/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures

Size: px
Start display at page:

Download "Sprecher + Schuh s broad line of IEC/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures"

Transcription

1 Enclosed ontactors Sprecher + Schuh s popular contactor lines housed in a variety of enclosures Sprecher + Schuh s broad line of E/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. ataloged enclosures include: 2 Type 3R ndustrial usttight Raintight (outdoor) X, orrosion Resistant Non-etallic Even though these are the most popular enclosure types for most industrial applications, we can house any contactor in a custom enclosure of your choice. Quality enclosures ensure the highest confidence Sprecher + Schuh only sources enclosures from name brand manufacturers, ensuring the highest quality. We primarily use enclosures that meet UL Standards, i.e.,, Type 3R, etc., however, we can also source E-type enclosures at your request. Enclosures are sized first to accommodate the depth of the contactor and offer sufficient electrical clearances to satisfy UL. Add a variety of modifications f you need a larger enclosure than what is specified in our catalog, your sales representative and our Engineering department will work with you to customize any of our enclosed products to suit your exact specifications. Any combination of enclosure types, sizes, pilot devices, meters and other modifications can be combined to provide exactly the panel you need. Precisely match the contactor to the application Unique to E-style contactors is the ability to select the exact device required for a specific application. By identifying the conditions under which the contactor will be used, i.e., resistive loads, reversing, inching and plugging, etc., published life-curve data predicts contact life in millions of operations. This information enables you to select the precise contactor for your application without buying too much or too little. Refer to Section A in this catalog for detailed technical information on all Sprecher + Schuh contactors. Other unique features Virtually all Sprecher+Schuh contactors offer one or more of the latest design techniques and innovations, such as electronically controlled coils, field installable auxiliary contacts or universal accessories across the entire contactor family. Type 3R X 35

2 - A oil Non-Reversing - Series A, Non-Reversing A7 & A9 - UL/SA - aximum Horsepower 2 [Type 3R ➋] ndustrial usttight Enclosed 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ A7-9- -G0 211 A A L A G0 244 A A L A G0 259 A A L A G0 276 A A L A G0 324 A A L A G0 365 A A L A G0 520 A A L A G0 540 A A L A G0 560 B A A G0 617 B A A G0 674 B A A G0 848 B A O A G0 ➍ 1424 E A ➍ 1592 Q A G0 ➍ 1652 E A ➍ 1847 Q A G0 ➍ 1938 E A ➍ 2386 R A G0 ➍ 2601 F A ➍ 3290 T A G0 ➍ 2775 F A ➍ 3429 T A G0 ➍ 3272 H A ➍ 3740 H A G0 ➍ 3763 H A ➍ 4300 H A9-400-E- -G R/F A9-400-E R/F A9-460-E- -G R/F A9-460-E R/F A9-580-E- -G R/F A9-580-E R/F A9-750-E- -G R/F A9-750-E R/F 860 ~ A9-860-E- -G R/F A9-860-E R/F 1060 ~ A E- -G R/F A E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example catalog number A becomes A R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ A9-116 A9-370 contactors are with E option for PL interface. hange catalog number to include -E. Example: A G0 becomes A9-116-E- -G0. See page 104 for price adder. 36 iscount Schedule B7

3 - A oil Non-Reversing - Series A, Non-Reversing A7 & A9 - UL/SA - aximum Horsepower ontactor ➋ X orrosion Resistant Enclosed 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ A7-9- -W0 446 N A S A W0 479 N A S A W0 495 N A S A W0 513 N A S A W0 560 N A S A W0 600 N A S A W0 617 N A S A W0 653 N A S A W0 754 O A U A W0 811 O A U A W0 869 O A U A W0 985 O A U A W0 ➍ 2011 Q A ➍ 1810 W A W0 ➍ 2333 Q A ➍ 2100 W A W0 ➍ 2565 R A ➍ 3429 X A W0 ➍ 3412 T A ➍ 4387 X A W0 ➍ 3545 T A ➍ 4469 X A W0 ➍ 4206 H A ➍ 5297 Y A W0 ➍ 4837 H A ➍ 6092 Y A9-400-E- -W R/F A9-400-E R/F A9-460-E- -W R/F A9-460-E R/F A9-580-E- -W R/F A9-580-E R/F A9-750-E- -W R/F A9-750-E R/F 860 ~ A9-860-E- -W R/F A9-860-E R/F 1060 ~ A E- -W R/F A E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page ➊ imensional information starts on page 122. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ A9-116 A9-370 contactors are with E option for PL interface. hange catalog number to include -E. Example: A W0 becomes A9-116-E- -W0. See page 104 for price adder. iscount Schedule B7 37

4 - A oil Reversing - Series AU, Reversing AU7 & AU9 - UL/SA - aximum Horsepower 2 [Type 3R ➋] ndustrial usttight Enclosed 200V 230V 460V 575V NO N ➍ atalog Number Price ➊ atalog Number Price ➊ AU7-9- -G0 562 A AU AU G0 633 A AU AU G0 674 A AU AU G0 692 A AU AU G0 807 A AU AU G0 888 A AU AU G0 953 B AU AU G B AU AU G AU O AU G AU O AU G AU O AU G AU O AU G0 ➎ 2681 E AU ➎ 2848 Q AU G0 ➎ 3110 E AU ➎ 3304 Q AU G0 ➎ 3877 E AU ➎ 4175 R AU G0 ➎ 5362 F AU ➎ 5850 T AU G0 ➎ 5702 F AU ➎ 6165 T AU G0 ➎ 6387 H AU ➎ 6855 H AU G0 ➎ 7345 H AU ➎ 7883 H AU9-400-E- -G R/F AU9-400-E R/F AU9-460-E- -G R/F AU9-460-E R/F AU9-580-E- -G R/F AU9-580-E R/F AU9-750-E- -G R/F AU9-750-E R/F 860 ~ AU9-860-E- -G R/F AU9-860-E R/F 1060 ~ AU E- -G R/F AU E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example catalog number AU becomes AU R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On AU7 reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). ➎ AU9-116 AU9-370 contactors are with E option for PL interface. hange catalog number to include -E. Example: AU G0 becomes AU9-116-E- -G0. See page 104 for price adder. 38 iscount Schedule B7

5 - A oil Reversing - Series AU, Reversing AU7 & AU9 - UL/SA - aximum Horsepower ontactor ➋ X orrosion Resistant Enclosed 200V 230V 460V 575V NO N ➌ atalog Number Price ➊ atalog Number Price ➊ AU7-9- -W0 668 N AU U AU W0 733 N AU U AU W0 774 N AU U AU W0 814 N AU U AU W0 904 N AU U AU W N AU U AU W N AU U AU W N AU U AU W O AU V AU W O AU V AU W O AU V AU W O AU V AU G0 ➍ 3282 Q AU ➍ 3030 W AU G0 ➍ 3807 Q AU ➍ 3515 W AU G0 ➍ 4569 R AU ➍ 5692 X AU G0 ➍ 6490 T AU ➍ 7348 X AU G0 ➍ 6775 T AU ➍ 7317 X AU G0 ➍ 7357 H AU ➍ 8532 Y AU G0 ➍ 8461 H AU ➍ 9812 Y AU9-400-E- -G R/F AU9-400-E R/F AU9-460-E- -G R/F AU9-460-E R/F AU9-580-E- -G R/F AU9-580-E R/F AU9-750-E- -G R/F AU9-750-E R/F 860 ~ AU9-860-E- -G R/F AU9-860-E R/F 1060 ~ AU E- -G R/F AU E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page ➊ imensional information starts on page 122. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ One N.. auxiliary contact is used for electrical interlocking. On AU7 reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). ➍ AU9-116 AU9-370 contactors are with E option for PL interface. hange catalog number to include -E. Example: AU W0 becomes AU9-116-E- -W0. See page 104 for price adder. iscount Schedule B7 39

6 - A oil Non-Reversing Single Phase - Series B Single Phase, Non-Reversing B7 - UL/SA - aximum Horsepower Single Ø 2 [Type 3R ➋] ndustrial usttight X orrosion Resistant Enclosed 115V 230V NO N atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ B7- B7- B7- B7-25 1/2 1 1/ G0 211 A L 9- -W0 446 N S1 25 1/ G0 244 A L 12- -W0 479 N S G0 259 A L 16- -W0 495 N S G0 276 A L 23- -W0 513 N S G0 324 A L 30- -W0 560 N S G0 365 A L 37- -W0 600 N S / G0 520 A L 43- -W0 617 N S G0 540 A L 55- -W0 653 N S G0 560 B W0 754 O U G0 617 B W0 811 O U / G0 674 B W0 869 O U1 Larger sizes. ontact your Sprecher + Schuh representative. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example catalog number B becomes B R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. 40 iscount Schedule B7

7 - A oil Reversing Single Phase - Series BU Single Phase, Reversing BUR7 (Reconnectable Winding - Three Lead otor) - UL/SA - aximum Horsepower Single Ø 2 [Type 3R ➋] ndustrial usttight X orrosion Resistant Enclosed 115V 230V NO N ➍ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUR BUR BUR BUR 25 1/2 1 1/ G0 562 A W0 668 N U1 25 1/ G0 635 A W0 733 N U G0 676 A W0 774 N U G0 692 A W0 814 N U G0 807 A W0 904 N U1 Single Phase, Reversing BUS7 (Series Winding Four Lead Repulsion nduction otor) - UL/SA - aximum Horsepower Single Ø 2 [Type 3R ➋] ndustrial usttight X orrosion Resistant Enclosed 115V 230V NO N ➍ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUS BUS BUS BUS 25 1/2 1 1/ G0 562 A W0 668 N U1 25 1/ G0 635 A W0 731 N U G0 676 A W0 774 N U G0 692 A W0 814 N U G0 807 A W0 904 N U1 Single Phase, Reversing BUP7 (Parallel Winding Four Lead apacitor or Split Phase otor) - UL/SA - aximum Horsepower Single Ø 2 [Type 3R ➋] ndustrial usttight X orrosion Resistant Enclosed 115V 230V NO N ➍ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUP BUP BUP BUP 25 1/2 1 1/ G0 562 A W0 668 N U1 25 1/ G0 635 A W0 731 N U G0 676 A W0 774 N U G0 692 A W0 814 N U G0 807 A W0 904 N U1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number BUx becomes BUx R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On BU reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). iscount Schedule B7 41

8 NEA - A oil Non-Reversing - Series AN7, Non-Reversing AN7 NEA Size aximum Horsepower 2 [Type 3R ➋] ndustrial usttight 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ AN G0 384 A AN L AN G0 409 A AN L AN G0 575 A AN L AN G0 819 A AN L AN G B AN NEA Size aximum Horsepower X orrosion Resistant 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ AN W0 755 N AN S AN W0 779 N AN S AN W0 946 N AN S AN W0 971 N AN S AN W O AN U1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AN becomes AN R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. 42 iscount Schedule B8

9 NEA - A oil Reversing - Series AUN7, Reversing AUN7 NEA Size aximum Horsepower 2 [Type 3R ➋] ndustrial usttight 200V 230V 460V 575V NO N ➍ atalog Number Price ➊ atalog Number Price ➊ AUN G0 997 A AUN AUN G A AUN AUN G A AUN AUN G B AUN AUN G AUN O NEA Size aximum Horsepower X orrosion Resistant 200V 230V 460V 575V NO N ➍ atalog Number Price ➊ atalog Number Price ➊ AUN W N AUN U AUN W N AUN U AUN W N AUN U AUN W N AUN U AUN W O AUN V1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications Refer to page ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number AUN becomes AUN R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On AU7 reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). iscount Schedule B8 43

10 Enclosed Lighting ontactors - A oil - Series AL / AVL Electrically Held with A oil Ampere Rating ➌ See page A46 Number of Poles Standard ontacts ➎ NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. 2 [Type 3R ➏] ndustrial usttight NO N atalog Number Price ➍ atalog Number Price ➍ AL G0 414 A AL L AL G0 588 A AL L AL G0 980 B AL echanically Held with A oil ➊ Ampere Rating ➌ Number of Poles Standard ontacts ➎ 2 [Type 3R ➏] ndustrial usttight NO N atalog Number Price ➍ atalog Number Price ➍ AVL G0 R/F R/F AVL R/F R/F See page AVL G0 R/F R/F AVL R/F R/F A AVL G0 R/F R/F AVL R/F R/F Larger sizes. ontact your Sprecher + Schuh representative. escription The AL7 electrically held contactors and AVL7 mechanical held contactors are cul rated and labeled for tungsten and ballast lighting duty applications at 20, 30, and 60 amperes respectively. Operation of echanically Held ontactor with ON-OFF Pushbutton atalog number AVL7 consists of a AL7 contactor with V7-11 mechanical latch. epressing the ON button energizes the L coil and the contactor closes. The mechanical latch locks the contactor in the closed position. The L coil is then de-energized by the coil, clearing contact UL (Terminals 65-66) to remove voltage. epressing the OFF button energizes the UL coil, and the mechanical latch releases the contactor. The UL coil is immediately de-energized by the coil clearing contact L (Terminals 13-14) to remove voltage. The contactor is now open. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications 44 Refer to page ➊ The N.O. auxiliary is used to mechanically latch the control circuit and is not for use by customer for other uses. ➌ Engineering practice permits 2.5 x e to be applied to a contactor when 3 poles are connected in parallel for single phase discharge lamp (ballast lighting) applications. Example: A AL Lighting ontactor plus a A7-P-B23 Paralleling Link can be used on a 50A ballast load. Applying parallel conductors to incandescent lamp loads does NOT result in a greater permissible load. Paralleling Links can be found in the Accessories section. ➍ imensional information starts on page 122. ➎ ontactors are equipped with number and type of auxiliaries indicated. See 108 to order additional or different auxiliary contacts. ➏ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example: AL becomes AL R0. Price remains the same. iscount Schedule B7

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

Orange Express Selection Guide Table of Contents

Orange Express Selection Guide Table of Contents Orange Express Selection Guide Table of Contents General escription...2 KWKstarters...4 KWKstarters...6 KWKstarters Enclosure imensions...8 FVNR CA7 Contactors, Enclosed...10 FVR CA7 Contactors, Enclosed...11

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494] 7-2 Lighting ontactors Open ontrol June 2005 N5 lectrically Held Vol. 2, Ref. No. [09] ontents eatures Instructional Leaflets 7 escription Page lectrically Held Product escription....... 7-2 pplication

More information

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts 0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

Power electronic brakes

Power electronic brakes Power electronic brakes Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB) Series features full-wave

More information

Definite Purpose Contactors

Definite Purpose Contactors 1 & 2 Pole - Series CDP2 One and Two Pole with C Coil (Open type only) ➍ mps Poles Locked Rotor mps mps ➋ Maximum H.P. 240V ➋ 480V 600V 120V 240V ➋ 30 ➊ 1 ➏ 150 75 50 40 1 2 CDP2-1P30- ➎ 69.54 50 30 ➊

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors .2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in

More information

Starters + Enclosed Product

Starters + Enclosed Product Starters + Enclosed Product General Description... 2 atalog Number oding... 4 Enclosure Ratings... 6 The Orange Express Program... 8 ustom ontrol Panels... 10 Fractional Manual Starters... 12 KWIKstarters...

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches es Series es... 2 Assemblies... 11 s... 15 Accessories... 25 Technical Information... 26 Dimensions... 31 Series R-Line es... 34 s... 39 Accessories... 40 Technical Information... 41 Dimensions... 42 es

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Series 11 used and Non-used isconnect Switches (30 & 60A) W A E H imension Approximate imensions in mm (in) Reference H W A ➊ E ➊ A1 108 (4-1/4) 120 (4-3/4) 101 (4) 90 (3-9/16) 105 (4-1/8) 85 (3-11/32)

More information

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors Selection ompact Definite Purpose Motor ontrol TLOG SELETION Definite Purpose ing System 2 D N 2 Model = ontactor = Three-Phase Starter = Single-Phase Starter Type 2 = Non-Reversing 27 = Non-Reversing

More information

E C N A A F -

E C N A A F - 33-52 NA ontactors & Starters 3-Phase agnetic Starters nclosed Freedom Line January 1 Vol. 2, Ref. No. [0068] Selection Table 33-102. NA Freedom Line nclosed ontrol ing System 33 esign Page N - NA 33-40

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Type E/F Simplex & Duplex Pump Controllers

Type E/F Simplex & Duplex Pump Controllers Type E/ Simplex & Duplex Pump Controllers Simplex Pump Controllers A single KTA7 motor controller plus matching CA7 contactor can be combined in an enclosure as a Simplex Combination Controller for pumping

More information

Accessories - Field Installable

Accessories - Field Installable Accessories - Field Installable A7 ontactors Type 1 General Purpose Enclosures ➋➌ Starters & Enclosed Products Enclosure (Box) Kit Includes: Hinged cover Backpan pre-drilled for listed arrangements (not

More information

Intelligent Softstarter Controllers

Intelligent Softstarter Controllers Intelligent Softstarter Controllers General escription... 2 Custom Softstarter Panels... 4 Series PCS Controllers... 6 Selection Guide... 8 Accessories... 19 Replacement Parts... 21 Technical Information

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

6.1. Lighting Contactors. Contents. Application Description. Product Overview. Open Control

6.1. Lighting Contactors. Contents. Application Description. Product Overview. Open Control .1 - Contents Description C30CN Mechanically and Electrically Held.... CN35 Electrically Held.................... A202 Magnetically Latched................ Page V5-T-3 V5-T-1 V5-T-23 Product Overview C30CN

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Benefits of using the Eaton S811+ soft starter to improve uptime and lower maintenance costs

Benefits of using the Eaton S811+ soft starter to improve uptime and lower maintenance costs Why soft start a motor? The most significant benefits of soft starting a motor come from reduced mechanical and electrical stress. This not only translates to lower maintenance costs, but significantly

More information

Series CA6 Contactors

Series CA6 Contactors Series CA6 Contactors The modern contactor for demanding applications from 75 to 600HP (@460V) - 00 to 700HP (@ 575V) Sprecher + Schuh s CA6 contactor line combines the simple function of our popular CA7

More information

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry. www.usa.siemens.com/controls NEA Pump Controls Class 82 slim line NEA pump controller for the agricultural industry Answers for industry. Class 82 Slim Line NEA Pump Controller Typical applications include:

More information

D I D /240 I. D x /240 I D / x x /24 I. D x /120

D I D /240 I. D x /240 I D / x x /24 I. D x /120 ndustrial ontrol Transformers lass 9070 www.square.com or the most up-to-date information The T units are designed for the global market and are the best choice when size and cost are of concern. This

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

TYPE LS-K CONTACTORS TECHNICAL SPECIFICATIONS

TYPE LS-K CONTACTORS TECHNICAL SPECIFICATIONS TYPE LSK CONTACTORS TECHNICAL SPECIFICATIONS LSK CONTACTORS FROM LS K TO LS K INTERNATIONAL RATINGS Type Style Rated insulation voltage Ui Rated impulse voltage Uimp kv Mechanical endurance AC operation

More information

4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors

4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors Direct Current Contactors.7 Contents Description Mill Type Contactors....................... 600V Contactors.......................... DPM 750V Contactor...................... AVD Contactor...........................

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16N0 NM Size 1 Starter NM Size 1 ontactor.1 Product Overview.............................................. 242 Features, enefits and Functions..................................

More information

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th NM ontactors and Starters NM N16N0 NM Size 1 Starter.1 Product Overview.............................................. Features, enefits and Functions.................................. Standards and ertifications......................................

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V)

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V) Series K Three and four pole contactors 150 to 825 (3) 200 to 1250 (1) ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K13: auxiliary

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Industrial Power Resistors Euclid Type SSR 1.3 to 101 Amperes

Industrial Power Resistors Euclid Type SSR 1.3 to 101 Amperes Hubbell Industrial ontrols, Inc. Euclid Power Resistors alog & May 2010, Replaces February 1998 Industrial Power Resistors Euclid Type SSR 1.3 to 101 mperes Features The Type SSR Industrial Power Resistor

More information

XT SERIES Jockey Pump Controllers Features

XT SERIES Jockey Pump Controllers Features XT SERIES Jockey Pump Controllers Features XT Series Jockey Pump Controllers March 2012 1-1 XT Power Controls The XT Series of Jockey Pump Controllers incorporate Eaton s XT Power Controls which are designed

More information

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1... 100HP 400HP 700HP 1000HP 1400HP PCS Softstarter Controller IN-rail mountable microprocessor controller for 3-phase motors up to 480A (3...85A din-rail mountable) Provides three different starting modes

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose Contactors General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Contactors Series C8 Miniature Contactors and Starters... 3

More information

Baldor Basics: Motors

Baldor Basics: Motors Baldor Basics: Motors Edward Cowern, P.E. A continuing series of articles, courtesy of the Baldor Electric Co., dedicated primarily to motor basics; e.g. how to specify them; how to operate them; how and

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Crane Control. Crane Control 1. Contents. Description Heavy-Duty Brakes Shoe Brakes Magnetically Operated Master and Limit Switch Family

Crane Control. Crane Control 1. Contents. Description Heavy-Duty Brakes Shoe Brakes Magnetically Operated Master and Limit Switch Family October 008 Contents Description Page HeavyDuty Brakes Shoe Brakes Magnetically Operated........................... Master and Limit Switches Type F Master Switches GH0............................... Type

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER 1 & 3 Phase, 50/60Z, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides a simple and dependable starting option with a wide electronic overload

More information

Series CA7 Contactors

Series CA7 Contactors Series CA7 Contactors Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 75HP @ 46V Over years of design experience has produced Sprecher + Schuh s seventh generation

More information

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale S&C Omni-Rupter Switches Outdoor istribution (14.4 kv and 5 kv) Specifications Conditions of Sale STNR: Seller s standard conditions of sale as set forth in Price Sheet apply. SPECIL TO THIS PROUCT: INCLUSIONS:

More information

Series CA6 Contactors

Series CA6 Contactors Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 100 to 700HP (@ 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Magnetic Motor Controls

Magnetic Motor Controls ^p Magnetic Motor ontrols NMA atalog Numbering System General SP urre it Range la ombination Starter (Non Fusible, Fusible) ombination Starter (ircuit Breaker) Reversing ombination Starter (Non Fusible,

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

Variable Frequency AC Motor Drive Units

Variable Frequency AC Motor Drive Units 14 Variable Frequency A Motor Drive Units ulletin 2162T and 2163T PowerFlex 40 Drive................................................. 171 These combination variable frequency A motor drive units are specifically

More information

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL 13686.00 MECHANICAL AND ELECTRICAL COORDINATION 230002-1 SECTION 230002 MECHANICAL AND ELECTRICAL COORDINATION 1.1 WORK INCLUDED PART 1 - GENERAL A. Work Included in This Section: Materials, equipment,

More information

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide VersaRupter 5-38 kv Load Interrupter Switch Technical Guide NOTICE Components in this catalog are intended for use by switchgear assemblers engaged in original equipment manufacturing. All sales are subject

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16DN0 NM Size 1 Starter.1 Freedom Series Product Overview........................................ Features, enefits and Functions............................ Standards and

More information

R-Rated medium voltage fuses for motor circuit protection

R-Rated medium voltage fuses for motor circuit protection Technical ata 6001 Supersedes September 2017 Features and benefits escription: Indoor/enclosure, R-Rated medium voltage, current-limiting fuses for motor circuit protection. urrent-limiting R-Rated fuses

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Softstarters. Softstarters Power electronic brakes Type PEB

Softstarters. Softstarters Power electronic brakes Type PEB Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit   Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Force-Guided s & Power Contactors For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Multi-pole Power for Contactor Current

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊ Series U/CSA Fused Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J Fuses ➋ 30

More information

FJ303-3PB6B. 4X Plastic 12. Catalog List Catalog List number price number price

FJ303-3PB6B. 4X Plastic 12. Catalog List Catalog List number price number price 3 Pole 30A 800A 7 FJ30X-3P02A 3 Pole, 0V, 30A 800A UL 98 UL 98 UL general purpose amp rating 3 Pole, 0V, 30A 800A UL general purpose amp rating Fuse X Stainless Catalog List Catalog List Catalog List Catalog

More information

4.1. Lighting Contactors. Contents Description UL Rated AC Contactors Catalog Number Selection...

4.1. Lighting Contactors. Contents Description UL Rated AC Contactors Catalog Number Selection... .1 Contents Description Catalog Number Selection................ Enclosures............................ Cover Control.......................... Product Selection.................... Operation Non-Combination

More information

KT4 Manual Motor Starters

KT4 Manual Motor Starters s General Description...F99 Quick Selection Guide...F100 Accessories...F101 Contact Blocks...F101 Adapter Plates...F101 Release Modules...F102 Connecting Modules...F102 Mounting...F103 Enclosures...F103

More information

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up Master atalog 125 s and ontactors Section R Product Bulletin R1000 Issue Date 0493 R1000 Series s The R1000 Series s switch line voltage devices from low voltage controllers. Plug-in DPDT relays and snap-in

More information

Vacuum Contactors and Starters

Vacuum Contactors and Starters Vacuum s and Starters Size 4 Vacuum.1 Product Description....................................... Application Description.................................... Operation...............................................

More information

Motorized Systems for Interior Window Coverings 2014

Motorized Systems for Interior Window Coverings 2014 12 25 00/SMA Buyline 5973 ized Systems for nterior Window Coverings 2014 C O M M E R C A L H O S P T A L T Y R E S D E N T A L 3351 Jack Northrop Ave., CA 90250-4426 Phone: 310-220-2600 / 800-533-3040

More information

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22.

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22. 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 121264CHC Encl 12X12X6 N4 Enclosure Cooper B-Line/Cable Tray Catalog Number Manufacturer escription Weight per unit Product

More information

9070T150D1 Industrial Control Transformer, 150VA

9070T150D1 Industrial Control Transformer, 150VA Product Data Sheet 9070T150D1 Industrial ontrol Transformer, 150 Technical haracteristics Application Approvals atalog Reference Number Depth Height Width Winding Material Temperature Rise Type Primary

More information

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. usa.siemens.com/controls Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

For many applications

For many applications Series 40 Amp Rugged and dependable 40 amp switches for industrial applications Sprecher + Schuh s rugged rotary cam switches are available for most control and load applications up to 40 amps. A well

More information

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to 150 HP @ 230 VAC, 3 HP to 600 HP @ 460 VAC without NEA1 Enclosures odel Numbers 912FKxxxx and 913FKxxxx Instruction anual

More information

US Catalog. Motor protection and control AF Range contactors & overload relays

US Catalog. Motor protection and control AF Range contactors & overload relays US Catalog Motor protection and control AF Range contactors & overload relays Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors (500

More information

Motorized Systems for Interior Window Coverings 2005

Motorized Systems for Interior Window Coverings 2005 12498/SMA Buyline 5973 Motorized Systems for nterior Window Coverings 2005 C O M M E R C A L H O S P T A L T Y R E S D E N T A L Complete design support and fabrication services of motorized systems; for

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Introduction A modular system of switchgear building blocks and cassettes provide untouchable

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

2017 CATALOG East Main Street Mesa, AZ

2017 CATALOG East Main Street Mesa, AZ 01 2017 CATALOG 9502 East Main Street Mesa, AZ 85207 888 964.1488 480 986.1488 sales@ruralelectric.com www.ruralelectric.com 02 ABOUT US Since 1964 Rural Electric has been providing electrical contracting

More information