Industrial Power Resistors Euclid Type SSR 1.3 to 101 Amperes

Size: px
Start display at page:

Download "Industrial Power Resistors Euclid Type SSR 1.3 to 101 Amperes"

Transcription

1 Hubbell Industrial ontrols, Inc. Euclid Power Resistors alog & May 2010, Replaces February 1998 Industrial Power Resistors Euclid Type SSR 1.3 to 101 mperes Features The Type SSR Industrial Power Resistor series consists of two different types of units: a hexwound unit and an edgewound unit. oth types feature continuous resistive elements supported on porcelain insulated core strips. Rugged shock-resisting, nonbreakable construction. Resistor assembly floats in slotted insulators. orrosion resistant materials. Negligible temperature coefficient of resistance. ssembled resistor banks provide double insulation to ground. Individual resistor units in an assembled bank can be replaced without disrupting adjacent units. variety of standard mounting frames, brackets, and enclosures. ssembled frames have identical mounting dimensions to old style assemblies. (Rod bolt mount) hubbell industrial controls, inc. escription Hexwound Resistors For relatively light current applications, the Hexwound resistors provide 13 different current ratings in the range of 1.3 to 7.2 amperes. For each rating the resistor units are available in five different coil lengths, enabling the resistors to be selected to precisely meet the application requirements. The Hexwound resistors consist of four basic parts, each engineered to perform a specific function. The core strip provides convenience in mounting while providing rugged support for the resistive element. The porcelain insulators are grooved to uniformly support each turn of the wirewound resistor element. Thus, each turn is insulated from each other and from the core strip. The terminals of the Hexwound resistor are engineered to assure sound electrical as well as mechanical connections. The terminal securely clamps to two turns of the resistor element. The resistive element of the hexwound resistor, like in all Euclid resistors, is a continuous element. Edgewound Resistors For heavier current requirements, the Edgewound resistors are available in 28 different current ratings, 8.5 amps through 101 amps without paralleling elements. The Edgewound units are available in five different lengths. Edgewound resistors are constructed of a helical coil supported by patented porcelain insulators on a steel core strip. The porcelain insulators provide the turn-to-turn and turn-to-core strip insulation. The resistive element is formed by edgewise winding stainless steel to form a continuous helix. The standard end terminal provided with edgewound resistors is a welded terminal. This welded terminal provides sound electrical connection to the resistive element while providing a good terminal for external connections. Intermediate taps or adjustable terminals are clamp type and can be positioned to practically any turn on the resistor. pplication These resistors are ideally suited for use in the secondary of wound rotor motors for accelerating, plugging, or speed regulating service. In the primary of the squirrel cage motors, these resistors serve as ballast resistors to eliminate the undesirable high torque and starting current associated with this type of motor. Industrial Power Resistors are also used in conjunction with appropriate control equipment to accelerate, plug, or dynamic brake motors. Other applications for resistors include: neutral grounding resistors, and dynamic braking, load banks, current limiting, and ballast for mercury vapor lamps. The rating versatility as well as the mounting flexibility, enable the resistors to be applied in other innumerable ways. Frames and Enclosures Euclid power resistors can be supplied factory mounted in a variety of galvanized steel frames and enclosures; standard frames, open frames, or mill frame. overs consist of cane metal enclosed, ventilated weatherproof enclosed or totally enclosed nonventilated. Standard frames are supplied with resistor assemblies unless otherwise specified.

2 Pricing Instructions & Examples Unassembled Resistors Order by: Part Numbers of Individual Resistor oils Part Numbers of djustable Terminals Part Number of Mounting Sockets and lips alog Numbers of Frame alog Numbers of over (if required) ssembled Resistors When specified by the customer, the following factory services are available at no extra charge: ssembly of oils into Frames Placement of one adjustable terminal per resistor coil, placed at the approximate ohmic value specified by the customer Part - Part No. No oils $144 $92 x 3 = $276 $ Part - Part No. No djustable Terminals... $12.$19 x 3 = $36 $ Part - Part No. No Mtg. Sockets & lips no harge* No. No. SSRS-35 Frame $100.$ No. No. 1M-35 over $160.$250 Total $572 $ Part - Part No. No oils $144 $92 x x 3 = $276 $ Part - Part No. No djustable Terminals... $12.$19 x x 3 = $36 $57 (Placed at 2.69 on each coil) Part - Part No. No Mtg. Mtg. Sockets & lips no harge* No. No. SSRS-35 Frame $100.$ No. No. 1M-35 over $160.$250 Total $895 $572 ssembly of cover to standard frame, if cover is required Special Features The following special services are available at a modest price addition: Resistor drawing, consisting of a connection diagram and ill of Materials Placement of more than one adjustable terminal per resistor coil Interwiring between coils in a frame Interwiring between stacked frames Part - Part No. No oils oils $144 $92 x x 33 = $276 $ Part - Part No. No djustable djustable Terminals Terminals$12..$19 x x 3 = $36 $ Part - Part No. No Mtg. Mtg. Sockets Sockets && lips lips.....no harge* No. No. SSRS-35 Frame $100.$156 Sub Total $645 $412 Interwiring oils, and Placement of... $64 $41 djustable Terminal per drawing (dd 10%) 1 -. No. 1M-35 over... $160 $250 Total $613 $959 For any of the above features add 10% to component price. (oils + Frames + djustable Terminals) Engineered Resistor ssemblies Hubbell Industrial ontrol s Engineering Staff will design resistor assemblies for your special application. Your inquiry should include (when possible) Type of Equipment/ontrol Involved; Function to be Performed; Motor/Load ata including duty cycle, total ohmic value, tap locations, ampere rating, and special ambient conditions. Note: * Mounting Sockets Must e Specified On Purchase Order. Included in price of coils when coils are furnished with frame dd the prefix H before all Part Numbers. Page 2 hubbell industrial controls, i

3 May 2010, Replaces February 1998 Hexwound Resistor oils ISOUNT OE EK MP Size 3 Size 4 Size 5 Size 6 Size 7 Part No. Ohms Part No. Ohms Part No. Ohms Part No. Ohms Part No. Ohms $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $250 Edgewound Resistor oils MP Page 3 ISOUNT OE EK Size 3 Size 4 Size 5 Size 6 Size 7 Part No. Ohms Part No. Ohms Part No. Ohms Part No. Ohms Part No. Ohms $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $349 dd the prefix H before all Part Numbers. mpere ratings are based on single coils operating in free air at a temperature rise not to exceed 300 for Hexwound Resistor oils or 375 for Edgewound Resistor oils.

4 May 2010, Replaces February 1998 Frames ISOUNT OE EK 2 oils 3 oils 4 oils 5 oils 6 oils 7 oils Open Frames SSRO-2 $150 SSRO-3 $150 SSRO-4 $175 SSRO-5 $175 SSRO-6 $200 SSRO-7 $200 Standard Frames SSRS-2 $156 SSRS-3 $156 SSRS-4 $187 SSRS-5 $187 SSRS-6 $218 SSRS-7 $218 Universal Mill Frames ccepts nine (9) Size 3 oils, alog No. SSRM-93, omplete catalog numbers by filling in resistor coil size after the listed catalog number. Open Frame overs ISOUNT OE EK No. of Frames M-2 2M-2 3M-2 4M-2 5M-2 1VW-2 2VW-2 3VW-2 4VW-2 5VW-2 1TE-2 2TE-2 Standard Frame Universal Mill Frame 2 oils 3 oils 4 oils 5 oils 6 oils 7 oils $250 $473 1M-3 2M-3 3M-3 4M-3 5M-3 1VW-3 2VW-3 3VW-3 4VW-3 5VW-3 1TE-3 2TE-3 $250 $473 1M-4 2M-4 3M-4 4M-4 5M-4 rane Metal $281 1M-5 2M-5 3M-5 4M-5 5M-5 Ventilated Weatherproof 1VW-4 2VW-4 3VW-4 4VW-4 5VW-4 $406 $780 $905 1VW-5 2VW-5 3VW-5 4VW-5 5VW-5 Totally Enclosed Non-Ventilated 1TE-4 2TE-4 $343 1TE-5 2TE-5 omplete catalog numbers by filling in resistor coil size after the listed catalog number. erate resistor coil amps by 50% when using the Totally Enclosed Non-Ventilated overs. Standard Frame with ane Metal overs $281 $406 $780 $905 $343 1M-6 2M-6 3M-6 4M-6 5M-6 1VW-6 2VW-6 3VW-6 4VW-6 5VW-6 1TE-6 2TE-6 $686 $998 $1,186 1M-7 2M-7 3M-7 4M-7 5M-7 1VW-7 2VW-7 3VW-7 4VW-7 5VW-7 1TE-7 2TE-7 $686 $998 $1,186 Standard Frame with Ventilated Weatherproof overs Standard Frame with Totally Enclosed Non-Ventilated overs Terminals & Mounting Sockets (iscount E32) Stainless Steel oil Jumpers with Hardware (iscount E39) Part No. escription djustable Terminals oils under 40 amps $28 $18 Part No. Rating mps oil Type oils over 40 amps $42 $ Hexwound $19 $ oils under 40 amps $42 $ Edgewound $19 $ oils over 40 amps $66 $ Edgewound $19 $ oils under 40 amps $48 $31 Terminals & dditional Mounting Sockets oils over 40 amps $72 $46 Edgewound End Terminal Modification dd the prefix H before all Part Numbers. ode Letter, Welded, short terminal, $6 $4 per oil Notes onsult factory for stainless steel or aluminum frame and cover pricing. Mounting Socket & lip Part No , $6 $4 per set See page 23 for pricing instructions.

5 imensions Standard Frame Standard Frame imensions No. of oil oils Size Open Frame 1.25" 1.25" dd 6" 6" dd 6" 6" 3" 1".50" 3".43" Removal of Resistor Insulators.50".87" Removal of Resistor Insulators 1" Open Frame imensions Universal Mill Frame No. of oil oils Size " 6.00" 2.50" 1.50" 26.50" 25.25" ccepts quantity of 9 Size 3 oils.62" 6".62" x.87" Mtg. Holes Page 5 hubbell industrial controls, i

6 imensions Standard Frame w/ overs imensions No. of oil oils Size ane Metal over ane Metal overs (4 Sides) Screened ottom Provide a Min. of 1" Spacing for Ventilation Ventilated Weatherproof over Solid over Screened ottom Provide a Min. of 1" Spacing for Ventilation 1" Typ..06".06" 6.06" dd 6" 7" dd 6" Note: erate resistor coil amps 50% when using Totally Enclosed Non-Ventilated overs Totally Enclosed Non-Ventilated over Note: erate resistor coil amps 50% when using Totally Enclosed Non-Ventilated overs Solid over.12" Typ. 6.06" Solid ottom 1.06".06" 1.06" dd 6" hubbell industrial controls, i Hubbell Industrial ontrols, Inc. a subsidiary of Hubbell Incorporated 4301 heyenne rive, rchdale, N Phone (336) Fax (336) sales@hubbell-icd.com

SSR Resistor. SSR Resistor. Resistor Rack. K Resistor HUBBELL. Table of Contents. Hubbell Industrial Controls, Inc.

SSR Resistor. SSR Resistor. Resistor Rack. K Resistor HUBBELL. Table of Contents. Hubbell Industrial Controls, Inc. Hubbell Industrial Controls, Inc. Power Resistors 3000 Catalog 3000 February 1998 Replaces August 1995 SSR Resistor Type Standard Frame Table of Contents Type Specifications... 2 SSR Resistor Type Universal

More information

Type K Features. Heavy, stainless steel terminals. Average 7652 watts per. single unit. Designed to NEMA resistor standards.

Type K Features. Heavy, stainless steel terminals. Average 7652 watts per. single unit. Designed to NEMA resistor standards. Hubbell Industrial Controls, Inc. Euclid Power Resistors Euclid Power Resistors Type K and Type HHC 38 to 695 Amperes Catalog & Price List January 2011, Replaces May 2010 Engineered for endurance, the

More information

100E. hubbell industrial controls, inc. EUCLIDTM

100E. hubbell industrial controls, inc. EUCLIDTM 100E hubbell industrial controls, inc. EUCLIDTM AC & DC Motor Controllers and Accessories Power & Neutral Grounding Resistors Pushbuttons Magnet Controllers Speed Switches Sensing Devices Drum Switches

More information

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts 0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed

More information

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494] 7-2 Lighting ontactors Open ontrol June 2005 N5 lectrically Held Vol. 2, Ref. No. [09] ontents eatures Instructional Leaflets 7 escription Page lectrically Held Product escription....... 7-2 pplication

More information

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508 Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:

More information

Cable & Wire Management

Cable & Wire Management Type 1 Screw over... 8-14 Type 1 Quick-onnect inge over... 15-20 Type 3R nviroshield... 21-24 Type 12... 25-31 eed-through Wireway Type 12... 32-35 eed-through Wireway Type 4X... 36-39 Wiring Trough Type

More information

Cable & Wire Management

Cable & Wire Management able & ire Management able & ire Management Lay-In ireway Type 1 Screw over... 8-14 Lay-In ireway Type 1 Quick-onnect inge over... 15-20 Lay-In ireway Type 3R EnviroShield... 21-24 Lay-In ireway Type 12...

More information

ECE 325 Electric Energy System Components 6 Three Phase Induction Motors. Instructor: Kai Sun Fall 2016

ECE 325 Electric Energy System Components 6 Three Phase Induction Motors. Instructor: Kai Sun Fall 2016 ECE 325 Electric Energy System Components 6 Three Phase Induction Motors Instructor: Kai Sun Fall 2016 1 Content (Materials are from Chapters 13-15) Components and basic principles Selection and application

More information

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase 2. Which part of a three-phase squirrel-cage induction motor is a hollow core? 3. What are

More information

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG COMPANY OVERVIEW Since 1970, we have been pioneering new developments in heater technology and providing

More information

PUNCHED GRID RESISTORS

PUNCHED GRID RESISTORS PUNCHD GRID RSISTORS PUNCHD GRID RSISTORS BCH un-breakable Punched Grid Resistors features an all welded current path for heavy duty applications. The units have been made robust, versatile and yet economical

More information

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase motor? Stator and Rotor 2. Which part of a three-phase squirrel-cage induction motor is a

More information

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale S&C Omni-Rupter Switches Outdoor istribution (14.4 kv and 5 kv) Specifications Conditions of Sale STNR: Seller s standard conditions of sale as set forth in Price Sheet apply. SPECIL TO THIS PROUCT: INCLUSIONS:

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

RESISTOR CONTROL OF WOUND ROTOR MOTORS

RESISTOR CONTROL OF WOUND ROTOR MOTORS RESISTOR CONTROL OF WOUND ROTOR MOTORS RESISTOR CONTROL OF WOUND ROTOR MOTORS The Wound Rotor Induction Motor or Slip Ring Motor is widely used for applications requiring speed control or low starting

More information

High Power Resistor Series. Token Electronics Industry Co., Ltd. Version: September 5, Web:

High Power Resistor Series. Token Electronics Industry Co., Ltd. Version: September 5, Web: Version: September 5, 2017 High Power Resistor Series Web: www.token.com.tw Email: rfq@token.com.tw Token Electronics Industry Co., Ltd. Taiwan: No.137, Sec. 1, Zhongxing Rd., Wugu District, New Taipei

More information

Type 4 Panel Enclosures

Type 4 Panel Enclosures Ground-Mount Enclosures Type 4 Free-Standing ata Sheet Finish Wash and phosphate undercoat NSI 61 gray polyester powder finish pplication Houses electrical controls and instruments Easy access panels or

More information

Sprecher + Schuh s broad line of IEC/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures

Sprecher + Schuh s broad line of IEC/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures Enclosed ontactors Sprecher + Schuh s popular contactor lines housed in a variety of enclosures Sprecher + Schuh s broad line of E/UL HP rated contactors can be purchased pre-installed in a variety of

More information

DYNAMIC BRAKING RESISTORS

DYNAMIC BRAKING RESISTORS DYNAMIC BRAKING RESISTORS Dynamic braking is the simplest and very widely used method of braking a load driven through a d.c motor as it involves no wear and tear unlike with mechanical brakes. For dynamic

More information

POWERTEC Brushless DC Motors

POWERTEC Brushless DC Motors INEX How to use this section This section covers our extensive line of high performance POWERTE and PTORQ Brushless Motors. Select the proper motor using one of the following procedures. If you are already

More information

Three Phase Transformers

Three Phase Transformers Three Phase Transformers ontents Three Phase - General Purpose... 26 Three Phase - General Purpose Scott ed... 30 Three Phase - dditional ombinations vailable... 31 Three Phase - ion Diagrams... 32 Series

More information

PUNCHED GRID RESISTORS

PUNCHED GRID RESISTORS PUNCHD GRID RSISTORS PUNCHD GRID RSISTORS BCH un-breakable Punched Grid Resistors features an all welded current path for heavy duty applications. The units have been made robust, versatile and yet economical

More information

NEMA Contactors & Starters A200

NEMA Contactors & Starters A200 March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

4412HS Wway 4X4X12 N1 HC Lay-In. Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information

4412HS Wway 4X4X12 N1 HC Lay-In. Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 ax: 936-560-4685 4412S Wway 4X4X12 N1 Lay-In ooper -Line/able Tray atalog Number Manufacturer Description Weight per unit Product ategory

More information

Ballasts For High Intensity Discharge Lamps

Ballasts For High Intensity Discharge Lamps allasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity

More information

D I D /240 I. D x /240 I D / x x /24 I. D x /120

D I D /240 I. D x /240 I D / x x /24 I. D x /120 ndustrial ontrol Transformers lass 9070 www.square.com or the most up-to-date information The T units are designed for the global market and are the best choice when size and cost are of concern. This

More information

VB-7000 Series 1/2 to 2 Globe Valves

VB-7000 Series 1/2 to 2 Globe Valves V-7000 Series 1/2 to 2 Globe Valves with MG350V Series SmartX ctuators schneider-electric.com 1 Product Description Schneider Electric MG350V non-spring actuators and V-7000 series two and three-way globe

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

Amphenol Amphenol Pcd Terminal Junction Systems

Amphenol Amphenol Pcd Terminal Junction Systems igh Quality Interconnect Products or Military and erospace pplications mphenol mphenol Pcd Terminal unction Systems Terminal unction Systems MIL-T-171 Series I lass MIL-T-171 Series I unction Modules QPL-approved

More information

Youngstown Power Limit Switches

Youngstown Power Limit Switches Class March, 2012 September, 2008 FRONTLINE AC CRANE CONTROL CLASS 6420 Youngstown Power Limit Switches CONTENTS Description Class Page General Information and Selection...... 2 Application Information.....

More information

POST GLOVER RESISTORS INC.

POST GLOVER RESISTORS INC. Introduction Post Glover specializes in motor control resistors the most popular use of our resistors for severe duty applications. Our resistors make it possible to start and stop extremely powerful electric

More information

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors .2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in

More information

Euclid DC Crane Controllers Catalog Price List 4100 April 2007 Page 1

Euclid DC Crane Controllers Catalog Price List 4100 April 2007 Page 1 Catalog Price List 4100 April 2007 Page 1 4110/4120 Travel Controllers 4110/4120 Travel Controllers provide reversing-plugging control of series or compound wound DC motors. the simple easy-tounderstand

More information

Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere

Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere Type EB, EBB, EBF and VEB DOUBLE SIDE BREK SWITCHES 8 kv through 62 kv 600 to 000 mpere TYPE EB 1 Morpac Industries, Inc. 2725 East Ginter Road Tucson, rizona 85706 520-294-452 FX 520-294-2 Type EB, EBB

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

HPS Imperator Machine Tool Industrial Control Transformer

HPS Imperator Machine Tool Industrial Control Transformer HPS Imperator Machine Tool Industrial ontrol Transformer The Perfect Solution The HPS Imperator line of machine tool industrial control transformers are specifically designed to meet the high inrush industrial

More information

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement. DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally

More information

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC 1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC Part #: MHFL-1000W Made in the USA The powerful and efficient MHFL-1000W metal halide light fixture from Larson

More information

Section A Busway

Section A Busway Section 8 800 5000 usway usway atalog Numbering System Section 8 800 5000 usway usway atalog Numbering System atalog numbers are composed of two basic parts the prefix (as below), plus the suffix of each

More information

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors Selection ompact Definite Purpose Motor ontrol TLOG SELETION Definite Purpose ing System 2 D N 2 Model = ontactor = Three-Phase Starter = Single-Phase Starter Type 2 = Non-Reversing 27 = Non-Reversing

More information

(RNW) Power Resistor Chamber. Token Electronics Industry Co., Ltd. Version: January 13, Web:

(RNW) Power Resistor Chamber. Token Electronics Industry Co., Ltd. Version: January 13, Web: Version: January 13, 2017 (RNW) Power Resistor Chamber Token Electronics Industry Co., Ltd. Web: www.token.com.tw Email: rfq@token.com.tw Taiwan: No.137, Sec. 1, Zhongxing Rd., Wugu District, New Taipei

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering GE Energy onnections Single Socket and Horizontal etering EP pproved Single Socket etering EP pproved pplication Information GE s Single Socket etering products are designed for residential use. They are

More information

Totally Enclosed Non-Ventilated

Totally Enclosed Non-Ventilated 5 15 to 500 kva 5 Applications n Designed for commercial and industrial loads in challenging environments Specifications n NEMA3R rated enclosure n Single Phase units 15 through 100 kva n Three Phase units

More information

Series 1 Steel - Straight Sections

Series 1 Steel - Straight Sections LST-1 able Systems - Straight Sections How The Service dvisor Works -Line knows that your time is important! That s why the color-coding system in this catalog is designed to help you select products that

More information

Air-Oil Systems, Inc. Gas Springs AGS 15 - AGS 28

Air-Oil Systems, Inc.   Gas Springs AGS 15 - AGS 28 Gas Springs GS 15 - GS 28 Gas Springs ontrols gas springs are reliable units designed to handle the demanding needs of the industrial and commercial markets. They are maintenance free and self-contained.

More information

No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together Recognized by UL and cul STATES Type have

More information

Current-limiting fuse mounts

Current-limiting fuse mounts Fusing quipment atalog ata 132046N Supersedes November 2015 urrent-limiting fuse mounts OOPR POWR SRIS eneral aton provides overload protection for all indoor and underground cable distribution systems

More information

Channel Cable Tray - Accessories & Fittings

Channel Cable Tray - Accessories & Fittings hannel able Tray - Straight Sections E-1 -Line series able Tray Systems hannel able Tray - ccessories & Fittings How The Service dvisor Works We know that your time is important! That s why the color-coding

More information

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly

More information

Series 1 Steel - Straight Sections

Series 1 Steel - Straight Sections - Straight Sections H-1 -Line series able Systems - ccessories & Fittings How The Service dvisor Works We know that your time is important! That s why the color-coding system in this catalog is designed

More information

Two Seas Metalworks Shell Lane fax Rev

Two Seas Metalworks Shell Lane fax Rev This catalog provides product information and pricing for our complete line of Battery Enclosures and Battery Racks designed specifically for the PV industry to hold different sized batteries from all

More information

Type 4 X Panel Enclosures

Type 4 X Panel Enclosures Ground-Mount s Type 4X ouble-oor EnviroShield Free-Standing with 3-Point Locking ata Sheet ccessories Full and half panels Side panels Swing panels Touch-up paint Mounting legs Rack angles Swing out frames

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary

More information

LK-FCTB August 2010 (Replaces LK-FCTB,April 2007) FPO. Direct Drive Fluid Coolers Technical Guide. Models PFG & RF6

LK-FCTB August 2010 (Replaces LK-FCTB,April 2007) FPO. Direct Drive Fluid Coolers Technical Guide. Models PFG & RF6 LK-FCTB August 010 (Replaces LK-FCTB,April 007) FPO Direct Drive Fluid Coolers Technical Guide Models PFG & Table of Contents Overview...................................................................................

More information

Electrical Tech Note 106

Electrical Tech Note 106 Electrical Tech Note 106 Biosystems & Agricultural Engineering Department Michigan State University Master Exam Study Guide and Sample Questions 1 Based on the 2014 NEC, Part 8 of PA 230, PA 407, and the

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

Series 1 Steel - Straight Sections

Series 1 Steel - Straight Sections Series 1 Steel - Straight Sections Series 1 Steel H-1 B-Line series Cable Tray Systems Series 1 Steel - ccessories & Fittings Series 1 Steel How The Service dvisor Works We know that your time is important!

More information

HPS Fusion General Purpose Enclosed Transformer

HPS Fusion General Purpose Enclosed Transformer HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio

More information

Gas Springs AGS 15 - AGS 28

Gas Springs AGS 15 - AGS 28 Gas Springs GS 15 - GS 28 Gas Springs ontrols gas springs are reliable units designed to handle the demanding needs of the industrial and commercial markets. They are maintenance free and self-contained.

More information

D-73P disconnect and bypass switches

D-73P disconnect and bypass switches Switches atalog Data 008005EN Supersedes pril 2016 OOPER POWER SERIES D-73P disconnect and bypass switches ontents Description Page D-73P disconnect switch....2 D-73P3 bypass switch....5 D-73P-D cutout

More information

AIR CORE REACTORS. Phoenix Electric Corporation

AIR CORE REACTORS. Phoenix Electric Corporation AIR CORE REACTORS Phoenix Electric Corporation PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed

More information

R-Rated medium voltage fuses for motor circuit protection

R-Rated medium voltage fuses for motor circuit protection Technical ata 6001 Supersedes ecember 2015 Features and benefits escription: Indoor/enclosure, R-Rated medium voltage, current-limiting fuses for motor circuit protection. urrent-limiting R-Rated fuses

More information

Applications. Standard Materials

Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date: CSDA Best Practice Title: Hi-Cycle Concrete Cutting Equipment Issue No: CSDA-BP-010 : Oct 1, 2010 Revised : Introduction Hi-cycle/high frequency concrete cutting equipment has become more prevalent in

More information

ELECTRICAL MAINTENANCE

ELECTRICAL MAINTENANCE ELECTRICAL MAINTENANCE II PRACTICAL JOURNAL DATA 1 EXPERIMENT NO. 1 AIM: TO FIND VOLTAGE RATIO OF A GIVEN TRANSFORMER. CIRCUIT DIAGRAM: OBSERVATION TABLE: Sr.No. 1 2 3 4 Primary Voltage (V 1 ) Secondary

More information

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.

More information

For many applications

For many applications Series 40 Amp Rugged and dependable 40 amp switches for industrial applications Sprecher + Schuh s rugged rotary cam switches are available for most control and load applications up to 40 amps. A well

More information

Table of Contents Lesson One Lesson Two Lesson Three Lesson Four Lesson Five Lesson Six Lesson Seven Lesson Eight Lesson Nine Lesson Ten

Table of Contents Lesson One Lesson Two Lesson Three Lesson Four Lesson Five Lesson Six Lesson Seven Lesson Eight Lesson Nine Lesson Ten Table of Contents Lesson One Lesson Two Lesson Three Introduction to Single-Phase Motors...3 Split-Phase Motors...21 Capacitor Motors...37 Lesson Four Lesson Five Lesson Six Repulsion Motors...55 Universal

More information

Pixus Technologies Catalog

Pixus Technologies Catalog The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 916.524.8242 CN: 519.885.5775 Product Diversity

More information

600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS

600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS 600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS PLEASE READ INSTRUCTIONS THOROUGHLY BEFORE BEGINNING. A. BI-PARTING TRAVEL 1. Before raising track into position, determine location of

More information

Type MTS Miniature Test Switches

Type MTS Miniature Test Switches Type MTS Miniature Test Switches o o o o Compact and versatile Front- and back-connected styles Safe, durable, rugged and reliable Recognized by CUL & UL DESCRIPTION In many panelboard, switchgear, metering,

More information

Euclid Full Voltage Magnet Controller

Euclid Full Voltage Magnet Controller Hubbell Industrial Controls, Inc. Euclid Full Voltage Magnet Controller Instruction & Renewal Parts Manual Instructions/Parts Manual Publication No. 180 Replaces Sept. 1991 4291 & 4295/ 96 Type 4291 Type

More information

Comfort. Rugged Motor and Dynamically Balanced Fan provides a high volume of hot air.

Comfort. Rugged Motor and Dynamically Balanced Fan provides a high volume of hot air. High apacity Horizontal lower Heater 2-50 kw 6,820-170,600 tuh 120, 208, 240, 277, 480 and 550 Volt 1 or 3 Phase or eiling Mounted onfigurations escription Rugged, industrial heaters are ideal for factories,

More information

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company

More information

www.megaresistors.com CUSTOMIZABLE $ EFFICIENT HIGH QUALITY CONTENTS 2 Our Philosophy What We Do 3 Product Overview 4 Neutral Grounding 5 High Resistance 6 Low Resistance 8 Dynamic Braking 10 Motor Control

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Clipper Defined. Shelving. Clipper Hi-Performance Shelving Systems. Growth with. Penco Hi-Performance Shelves. Growth with

Clipper Defined. Shelving. Clipper Hi-Performance Shelving Systems. Growth with. Penco Hi-Performance Shelves. Growth with Defined Clipper Hi-Performance Systems At the heart of the Clipper System is the ingenious Penco Clipper Clip. It is easily installed, holds the shelf firmly in place, can be repositioned at any time,

More information

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10 A6C A5C-B6C B5C B5H Model Power Voltages Model IP55 A6C A5C B6C B5C B5H Up to 2.400 kw Up to 11.000 V LV A6C - B6C - A5C - B5C MV B5H Frame 71 560 Pole 2, 4, 6, 8 and 10 Cooling IC 411 ( IC 416 optional)

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Applications Ideal for use in chemical and petrochemical plants, such as

More information

ches UL File No. E101598

ches UL File No. E101598 Instrument Transformers, Inc. Series Series 95 95 Swit Switches ches UL File No. E101598 INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the

More information

Wye or Delta Systems DS9181 (CSA Approved)

Wye or Delta Systems DS9181 (CSA Approved) 6-2 High-resistance Grounding Equipment Wye or Delta Systems DS9181 (CSA Approved) 240, 480, 600 Volts WHERE TO USE The function of a high-resistance grounding equipment is: 1. To provide a ground for

More information

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Solid-State Relays. Solid-State Relays. Features. Description. Overview Features Rugged, epoxy encapsulation construction 4,000 volts of optical isolation Subjected to full load test and six times the rated current surge before and after encapsulation Unique heat-spreader

More information

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings Page 1 Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings I. General This specification covers the design requirements for a pad-mounted capacitor

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers

More information

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced INDUCTION MOTOR INTRODUCTION An induction motor is an alternating current motor in which the primary winding on one member (usually the stator) is connected to the power source and a secondary winding

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

A 1.2 kv class externally removable secondary bushing

A 1.2 kv class externally removable secondary bushing OEM Equipment Catalog Data CA800018EN Supersedes July 2015 COOPER POWER SERIES 3010-4515 A 1.2 kv class externally removable secondary bushing General Eaton s Cooper Power series 3010-4515 A externally

More information

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities 3-35 kw 10,200-119,420 Btuh 208 to 600 Volts 1 or 3 Phase Meets NEC, OSHA and UL Requirements ATEX and GOST Models Available Refer to WR-80EP in the Controls section. F-4 Description Type is designed to

More information

Midwest Electric Products. AC Disconnects

Midwest Electric Products. AC Disconnects Midwest Electric Products isconnects Midwest Electric Products pplication Information rticle 440 of the National Electrical ode applies to electric motor-driven air conditioning and refrigerating equipment

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Applications Ideal for use in chemical and petrochemical plants, such as manufacturers

More information

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information