AIR CORE REACTORS. Phoenix Electric Corporation
|
|
- Stephen Hall
- 6 years ago
- Views:
Transcription
1 AIR CORE REACTORS Phoenix Electric Corporation
2 PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed for each application, taking into account the voltage, current, inductance, size constraints, and loss characteristics required to provide the most efficient design at the most economical price. Phoenix reactors can be designed to North American or International standards. The reactors are suitable for use outdoors or indoors. AIR CORE REACTORS Reactor Types: CURRENT LIMITING REACTORS Reduce short circuit levels to meet the system needs and reduce stresses on buses, insulators, circuit breakers, and other high voltage devices. FILTER REACTORS Provide tuned series resonant LC circuits to meet specified harmonic requirements and minimize the effects of dangerous harmonics on power systems. NEUTRAL GROUNDING REACTORS Limit line-to-ground fault currents and reduce stresses on power equipment. MULTI-LAYER UNIT TRANSIENT LIMITING REACTORS Connected to capacitor banks to limit inrush currents on energization or limit resonant system frequencies. These reactors also reduce overvoltages due to energization or restrike and reduce the magnitude and frequency of induced or secondary transients in control cables and ground grid step voltage. Special Reactor Types: BALANCING REACTORS Balance current flow in parallel circuits. MOTOR STARTING REACTORS Limit inrush current. HVDC APPLICATIONS Control harmonic currents. SHUNT REACTORS (size permitting) Compensate capacitive voltages. Phoenix Electric Corporation Tel: Fax:
3 Air Core Reactor Design Phoenix Electric reactors are air cooled, single or multi-layer, cylindrically wound units constructed on weather resistant fiberglass epoxy tubes with all materials chosen to meet the most severe thermal and electrical shocks and cycling requirements. Reactor coil windings are normally designed using all aluminum construction with the conductors individually insulated. Copper winding can be provided to meet special applications. Reactors are of outdoor weatherproof construction suitable for use without further protection. Each reactor is painted ANSI 70 Light Grey unless otherwise specified. Flat aluminum terminals are drilled to NEMA specifications unless otherwise specified to meet special customer requirements. Electrotin plated terminals can also be provided. Phoenix Electric Reactors are designed and constructed to be maintenance free. 1. Each reactor is encapsulated with epoxy impregnated fiberglass roving and tape. 2. The top and bottom of each reactor incorporates aluminum supports and terminals. 3. The dielectric integrity of the coil is assured by the pre-insulated and pre-tested conductor insulation. 4. The mechanical integrity is provided by the epoxy, fiberglass roving and tape system. 5. Support insulator(s).
4 9 REACTOR INSTALLATION WITH SUPPORT STANDS INSTALLATION The height and diameter of a reactor can be adjusted to meet various necessary physical needs or unusual space requirements. Connections to standard NEMA type pads can be provided vertically or horizontally. Special drilling for unusual connections can also be provided to meet any incoming or outgoing line direction. SUPPORT STANDS Phoenix Electric can provide support stands and/or pedestals, which are custom designed for each application. Aluminum or hot dip galvanized steel stands can be provided. Special designs are used in order to avoid loop currents. LOSSES All Phoenix Electric Reactors are computer designed to minimize initial cost and operating losses. CLEARANCES Minimum installation clearances must be maintained. The user should be aware of any limiting dimensions or clearances involving structural steel or reinforcing steel that may be used in nearby building or supporting structures. Non-magnetic supports can also be furnished by Phoenix Electric. ENCLOSURES Phoenix Electric can provide custom enclosures for indoor or outdoor applications when required. Special designs are used in order to avoid loop currents and eddy currents. Internal buswork can also be provided for ease of interfacing with external connection points. TECHNICAL SUPPORT Phoenix Electric will provide technical support for applications, design calculations, engineering, and field installation assistance. Don t hesitate to contact us. LOUVERED PANEL ENCLOSURE
5 E FILTER REACTORS SERVING AN INDUSTRIAL COMPLEX Serving the Industry since 1973 and with over 15,000 reactors in successful service, Phoenix Electric Corporation is known for strong engineering, experience and a commitment to excellence. 9 Medium and High Voltage Cable Connectors Air Core Reactors Specialty Switchgear and Engineered Control Systems Specialty Retrofits 500kV REACTOR UNDER IMPULSE TEST TESTING Phoenix Reactors are qualified per ANSI and IEC standards or special tests depending on customer requirements. The basic program of testing includes some or all of the following tests: Routine Tests Impulse Tests Thermal Current Calculation Mechanical Strength Test Impedance and Loss Test Temperature Rise Test Sound Level Test Seismic Analysis QUALITY ASSURANCE PROGRAM Phoenix Electric has established and maintains a comprehensive Quality Assurance Program. This program encompasses the major industry recognized standards including the International Standard ISO 9001 of Quality Management and Quality Assurance Standards.
6 AIR CORE REACTORS DATA REQUIRED WITH ORDER OR FOR BID PURPOSES 1. System Voltage (kv) 2. Frequency (Hz) 3. Basic Impulse Level (kv) 4. Reactance/Inductance (Ohms/Microhenries) 5. Continuous Current (A) 6. Short Circuit Levels (ka) - Time Duration (Sec) 7. Fundamental/Harmonic Frequency Levels(Hz) 8. Q Required for Filter Reactors 9. Insulators supplied or not supplied and TR No. or type to be used if not supplied by Phoenix Electric 10. Vertical or Horizontal Mounting 11. Three phase side by side or vertical stack mounting 12. Terminal configuration if not NEMA SG1 13. Dimensional Limitations 14. Number of Units Shipping Address: 25 North Street Canton, MA USA Mailing Address: P.O. Box 53 Boston, MA USA Tel: Fax: info@phoenixelectric-usa.com
Technical Specification For Outdoor Substation Harmonic Filter Banks
Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field
More informationCONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS
LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low
More informationPublication No.: PSG
TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More informationOutdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv
Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv SF6 circuit breaker EDT with integrated current transformer ABB is a world leader in live tank circuit breaker
More information43-SDMS-04 REV. 00 SPECIFICATIONS FOR
43-SDMS-04 REV. 00 SPECIFICATIONS FOR SHUNT CAPACITOR BANK 13.8 kv THROUGH 69 kv FOR PRIMARY DISTRIBUTION SUBSTATIONS This specification is property of SEC and subject to change or modification without
More informationCAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION
CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA ITALY POLAND INDIA CENTRAL & SOUTH AMERICA
More informationProduct Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher
TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...
More informationMedium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.
Medium Voltage Power Factor Correction Reactive Compensation Harmonic Filters POWER QUALITY Electrical Power Quality Management at its best. From electricity generation, transmission, thru its distribution
More informationB kv T&D GAS INSULATED SWITCHGEAR
GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationProduct Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher
TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 2 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...
More informationHPS EnduraCoil. Cast Resin Transformer
HPS EnduraCoil Cast Resin Transformer Hammond Power Solutions Inc. (HPS) is a leading manufacturer of standard and custom dry-type transformers in North America. Every HPS product is built with the quality
More informationOTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.
GE Grid Solutions OTCF Capacitor Voltage Transformers 72.5 kv to 800 kv In high and extra high voltage transmission systems, capacitor voltage transformers (CVTs) are used to provide potential outputs
More informationUnit Substation Transformers 5 and 15 KV Class
Transformers 5 and 15 KV Class 85 General Information Description Federal Pacific unit substation transformers are available in a wide variety of types and ratings to provide reliable and versatile electrical
More informationLV Capacitor CLMD Reliability for Power Factor Correction
LV Capacitor CLMD Reliability for Power Factor Correction Reliability for power factor correction CLMD construction The CLMD capacitor consists of a number of wound elements made with a dielectric of metallized
More informationMedium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks
Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks Product Selection & Application Guide Product Description GE's Thyristor Switched Harmonic Filter Banks (TSC), are custom designed
More informationMV Air Insulated Switchgear TAP17. Technical Data TGOOD
MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)
More informationTransforming Energy.. For Advanced Technology
Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial
More informationCheck points for the connection of Capacitor&Reactor
Application Reactor is used in conjuction with capacitor banks in series. Its main function is to compensative or produce reactive power. According to the purpose of use, reactor helps to limit inrush
More informationI Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL
Surge Arresters UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 Electrical Apparatus I235-93 GENERAL UltraSIL Polymer-Housed VariSTAR
More informationHIGH POWER RECTIFIER SYSTEMS
HIGH POWER RECTIFIER SYSTEMS STATE OF THE ART DESIGN AND ENGINEERING Dynapower Company is the world s largest independent manufacturer of High Power Rectifier Systems. We design, manufacture and test integrated
More informationDistribution transformers Efficiency over life-cycle
Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationFIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z
PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install fixed power factor correction equipment as specified herein and as shown on the contract drawings. This specification
More informationELG4125: Flexible AC Transmission Systems (FACTS)
ELG4125: Flexible AC Transmission Systems (FACTS) The philosophy of FACTS is to use power electronics for controlling power flow in a transmission network, thus allowing the transmission line to be loaded
More informationKuhlman Electric Corporation Volt Instrument Transformers
Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High
More informationSr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6
INDEX : Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3 2 Technical Perticular for Capacitor Unit 4 3 MV Surge Capacitor Unit Drawings 6 4 Technical Perticular for Surge Capacitor Unit 7 5 MV Energy
More informationLV Capacitor CLMD03 Power Module Instruction manual
LV Capacitor CLMD03 Power Module Instruction manual Table of Contents 1 Safety... 3 2 Upon reception... 3 2.1 Inspection on reception... 3 2.2 Storage- transportation handling... 3 3 Hardware Description...
More informationSurge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION
Surge Arresters UltraSIL Housed VariSTAR Station Class Surge Arresters Electrical Apparatus 235-88 GENERAL Cooper Power Systems has set a new standard of excellence for polymerhoused station class surge
More information33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT
33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar,
More informationHARMONIC FILTER REACTOR
380V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 415V capacitor only Design : According to VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationBushings for High Voltage AC Applications
Bushings for High Voltage AC Applications Selection guide 1ZSE 2750-100 en, Rev. 3, 2006-03-15 During selection of for high voltage applications several important factors have to be considered to ensure
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More information3TM Vacuum Contactors
Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents
More informationLV Capacitor Bank APC
LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks The ABB comprehensive solution for automatic
More informationMEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV
CE--C-en-REV.04 2016.1 MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE- Metal Clad switchboards family are designed for use in public and industrial distribution system up to 40,5kV for the operation and
More informationACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE
ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE hvgrid-tech designs and manufactures high voltage cable accessories for all types of cable systems, ranging from 69 kv to
More informationVolt Instrument Transformers
www. kuhlman. com Kuhlman Electric Corporation Instrument Transformers 1 Table of Contents Description Model Page Wound, Oil-Filled VT (High Accuracy available) UTE-145-OH 3-4 Wound, Oil-Filled CCVT (High
More informationWye or Delta Systems DS9181 (CSA Approved)
6-2 High-resistance Grounding Equipment Wye or Delta Systems DS9181 (CSA Approved) 240, 480, 600 Volts WHERE TO USE The function of a high-resistance grounding equipment is: 1. To provide a ground for
More informationPRODUCT SPECIFICATIONS
KLR Series Three Phase Reactors PRODUCT SPECIFICATIONS Lifetime Warranty Performance Guarantee K-Rated, UL/ULC-Recognized; CSA-Certified 3 Phase, 600V Class Gapped Iron Core Inductor All Copper Windings
More informationMEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV
MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators,
More informationUltravar TM AUTOMATIC POWER FACTOR CORRECTION & HARMONIC SOLUTIONS
AUTOMATIC POWER FACTOR CORRECTION & HARMONIC SOLUTIONS Contents Benefits of Power Factor Improvement... 4 ACCU-VAR Plus - AVC (50 to 600 KVAR) Standard and Optional Features... 5 240, 480, 600 Volt Equipment...
More informationGROUP D. Switch & Protective device.
GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated
More information16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12
16kA Solid Dielectric, Triple Option Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 27kV, 630A continuous current, 16kA symmetrical interrupting
More informationPhiCap Capacitors for Power Factor Correction
PhiCap Capacitors for Power Factor Correction Product Profile 2000 http://www.epcos.com PhiCap AC Capacitors for Power Factor Correction General The PhiCap series, is a well approved and reliable EPCOS
More informationGENERAL. CONSTRUCTION External
Surge Arresters VariSTAR Type AZG4 Surge Arresters for Systems through 400 kv IEC 20-kA; Line Discharge Class 4 Electrical Apparatus I235-84 GENERAL VariSTAR AZG4 Surge Arresters incorporate the latest
More informationLV Capacitor Bank APC
LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks The ABB comprehensive solution for automatic
More informationMedium Voltage Capacitors
Type MSCE and MSCD Features that matter: Single and Three-Phase Capacitors Up to 22 kv (50 / 60 Hz) Up to 1000 kvar For indoor and outdoor installation 1 Type MSCE and MSCD Application Product Scope The
More informationAC Line / Load Reactors
AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100
More informationStudy of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank
Day 2 - Session V-B 299 Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank Murali Kandakatla, B. Kondala Rao, Gopal Gajjar ABB Ltd., Maneja, Vadodara, India Thane Introduction
More informationPOWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar. Abel-Zhang,Power Quality Center Manager
POWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar Abel-Zhang,Power Quality Center Manager Contents Capacitor Unit Capacitor Shunt Bank Type Solution of Filter March 7, 2017 Slide 2 Contents
More informationLow voltage capacitors CLMD Improving power factor and enhancing power quality of your network
PRODUCT BROCHURE Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network s.a. ABB n.v. Power Quality Products Allée Centrale 10 Z.I. Jumet B-6040 Charleroi (Jumet)
More informationMidwest Dry Type Transformers
Midwest Electric Products Midwest Dry Type Transformers Reliable and Efficient Performance From a Name You Know DOE 2016 Efficiency Transformers Catalog General Information...2 General Purpose... 3 Single-Phase
More informationPOWER CAPACITORS. Cylindrical capacitor standard duty
Construction Dielectric: Polypropylene film Non PCB, Soft Polyurethane resin Extruded round aluminium can with stud Provided with discharge resistors Overpressure disconnector Features Three phase, delta
More informationMEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV
CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection
More informationFEBRUARY 14, 2017 Joslyn Hi-Voltage Capacitor switches customer presentation
FEBRUARY 14, 2017 Joslyn Hi-Voltage Capacitor switches customer presentation agenda Fundamentals Compelling value Product line overview VerSaVac (VSV) Product features and benefits Design Ratings Applications
More informationVariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified
Surge s Catalog Data CA235022EN Supersedes TD235009EN September 2014 COOPER POWER SERIES VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified General Eaton s Cooper
More information56-SDMS-07 REV. 01 SPECIFICATIONS FOR
56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice
More informationPhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system
Premium PFC Capacitors General capacitors in cylindrical aluminum cases have been designed for power factor correction in low-voltage plant. Loads like motors and transformers consume active power as well
More informationCAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION
CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA CENTRAL & SOUTH AMERICA MIDDLE EAST &
More informationIEC Separable Connectors 17.5 kv/24 kv, 630A
IEC Separable Connectors 17.5 kv/24 kv, 630A Front T-Body / Coupling (Rear) T-Body Connector Application The Chardon T-Body connectors are used to terminate polymeric cable to dead front apparatus such
More informationLongest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!
DB 750-205 January 2007 Supercedes: December 2006 Now available with Vacuum Interrupter Monitor VBT Switch 15kV - 69kV VBU-T Switch 69kV - 230kV Longest Life Product for Electric Furnace Applications!
More informationMOBILE SUBSTATION DESIGN Brad Bozich & Vitor Vieira 2755 Northwoods Parkway Norcross, Georgia
MOBILE SUBSTATION DESIGN Brad Bozich & Vitor Vieira 2755 Northwoods Parkway Norcross, Georgia 30071 678.982.8928 brad.bozich@efacec.com SCOPE This document is intended to help define the main parameters
More informationTechnical Specification for Pole Mounted Capacitor Rack
Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to
More informationPower Voltage Transformers for Air Insulated Substations
Power Voltage Transformers for Air Insulated Substations Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the application of a
More informationDistribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection
7 Distribution Dry Type Transformers 600 Volts Class Single and Three Phase 600 Volts Class Single Phase 0.25 167 KVA Three Phase 3 1000 KVA Features Standard units are UL listed and are designed in accordance
More informationFirst Applications on AltaLink s Network. Roggero Ciofani, P. Eng. Colin Clark, P. Eng.
First Applications on AltaLink s Network Roggero Ciofani, P. Eng. Colin Clark, P. Eng. Overview Technology Overview Applications and Alternatives Advantages Alberta Special Considerations Operational Implications
More informationAuxiliary Relay. Type RXP8n, RXPQ8n
Auxiliary Relay Type RXP8n, RXPQ8n ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering
More informationMedium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General
13 SWITCHGEAR Medium Voltage Equipment -1 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General Overview Features Siemens, 7, 1 and 38kV class medium voltage, one- or two-high vacuum circuit breaker switchgear
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationIEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector
www.chardongroup.com IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector Application Chardon Front T-Body / Coupling (Rear) T-Body connectors are fully
More informationModular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.
Modular Capacitor Systems Reactive Compen sation Copyright 2002 ABB. All rights reserved. 12/12/2002 Needs Customer A solution to suit Modular Substations Relocatable assets More value for money ABB A
More informationIndependent Testing Laboratory for High Voltage Equipment
T E S T I N G L A B O R A T O R Y Independent Testing Laboratory for High Voltage Equipment 1 CHALLENGING ENVIRONMENT The primary concern for utilities is to ensure grid reliability, efficiency, and security.
More informationDIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.
DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them
More informationBraking Resistors. customized solutions consistent casing design wire-wound the complete product range steel grid < cast iron
Braking Resistors with RESISTORS a system customized solutions consistent casing design wire-wound the complete product range steel grid < cast iron
More informationSharda Electronics & Co. An ISO 9001:2015 Certified Company
Sharda Electronics & Co. An ISO 9001:2015 Certified Company Business Profile We have been witnessing to change all our life and change continues to happen all around us every moment. Change is happening
More informationPantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance
Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Table of contents 02 03 04 05 06 07 08 Disconnectors from ABB Maximum reliability and minimal maintenance Technical
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationOIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC
OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench
More informationTransformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC
Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC 60137-2008 High current bushings for transformer Features Bushing Type CFPT version Porcelain Insulator Trench RIG technology for
More informationPrime Power Energie Systems Inc.
Prime Power Energie Systems Inc. C a s t C o i l Tr a n s f o r m e r s 100 kva to 30 MVA 2 3kV tto 34 2.3kV 34.5kV 5kV Extraordinary Quality, Reliability and Service Energy Efficient Low Total Owning
More informationOutdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications
Outdoor live tank SF 6 circuit breaker Type OHB for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers
More informationProduct brochure. Gas-insulated switchgear ELK-4, 800 kv Pioneering technology for extra-high voltage applications
Product brochure Gas-insulated switchgear ELK-4, 800 kv Pioneering technology for extra-high voltage applications ABB and 50 years of GIS innovation ABB is a leader in power and automation technologies
More informationABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers
ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type
More informationM T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation
M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 050516 2002 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RL Line/Load Reactors are components
More informationPretest Module 29 High Voltage Unit 1
Pretest Module 29 High Voltage Unit 1 1. Is a person qualified to work on high-voltage installations when this module is completed? 2. What is the code definition of high-voltage? 3. What is the IEEE definition
More information75 kva Transformer - 208V Delta Primary Voltage - 480V Delta Secondary Voltage - NEMA 3R
75 kva Transformer 208V Delta Primary Voltage 480V Delta Secondary Voltage NEMA 3R Part #: MTATX3P208D75KVA480DN3R Page: 1 The MTATX3P208D75KVA480DN3R 208D 3 Phase Energy Efficient Transformer from Larson
More informationGuideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society
Guideline No.: E-07(201501) E-07 TRANSFORMERS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and
More informationSolid Dielectric, Triple Option Reclosers Catalog O-vlt14
Solid Dielectric, Triple Option Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 27kV, 630A or 800A continuous current, 12.5 or 16kA symmetrical
More informationSolid Dielectric, Single Phase Recloser
Solid Dielectric, Single Phase Recloser Catalog O-vsp17 Viper-SP Viper-SP solid dielectric, single phase recloser combines the time-proven reliability of electronically controlled, vacuum fault interrupters
More informationwww. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1
WeSTinghouse Descriptive Bulletin 47-156 Page 1 liquid Filled, Self-Contained 112% 2500 Kva June, 1974 Supersedes DB 47-350, dated August 1972 E, D, C/2082/DB Descriptive Bulletin 47-156 Page 2 Westinghouse
More information045 : 2000 CEB STANDARD
045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.
More information013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS
013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification
More informationMedium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION
Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium