Single Socket and Horizontal Metering
|
|
- Dominic Dixon
- 5 years ago
- Views:
Transcription
1 GE Energy onnections Single Socket and Horizontal etering EP pproved
2 Single Socket etering EP pproved pplication Information GE s Single Socket etering products are designed for residential use. They are UL labeled and are manufactured with surface mounted outdoor enclosures. The units in this brochure are approved by EP. Our products range from 125 to 320 and are available in single phase or three phase. Specifications and eatures Single Phase or Three Phase UL Listed Tested and UL listed up to 10kI short circuit rating Selected items are utility approved E 3R enclosure Integral duplex ground extruded in neutral lug G90 galvanized bridge provides superior corrosion resistance Heavy duty lug screws provide stronger connection component for reliable termination 125 units have horn bypass kit that is field installable by changing slide-nut 200 units have jaws made of copper plated alloy and have reinforcing springs to help maintain electrical connections 200 units have slide-nuts that allow for ease of installation of conductors and help eliminate lost components 2
3 Single Socket etering EP pproved Single Socket omenclature Sockets with 4 Jaws/Terminals Standard Prefix U = UL Labeled U H RS GE GE = General Electric dditional eatures = luminum ab = arrel Lock = arrel Lock and Lock Guard G = ed ifth Terminal H = Horn ypass S = Screw Type Sealing Ring T = ed onnector (#14-#2 U-L) Z = 5/16" Hex Head onnector Screw mpere Rating 1 = 100 mps 2 = 200 mps Product Group esignation RS = Residential Service, Single Position Service esign 0 = Overhead 1 = ombination Overhead/Underground 2 = Underground, Side Wired 3 = ombination, Overhead/Underground, Side Wired Standard Suffixes = luminum abinet = Opeing = over Plate = eutral isconnect T = Large Hub Opening U = Large Hub over Plate aximum onductor (Line & Load) 0 = 3/8" Stud onnectors 1 = #2/0 onnectors 2 = #250 kcmil onnectors 3 = #350 kcmil onnectors 6 = #600 kcmil onnectors 9 = ual #500 kcmil onnectors Sockets with 4, 5 or 7 Jaws/Terminals Standard Prefix U = UL Labeled dditional eatures = luminum ab = arrel Lock = Spring Jaw Socket = arrel Lock and Lock Guard H = Horn ypass S = Screw Type Sealing Ring T = ed onnector (#14-#2 U-L) U T H GE GE = General Electric Standard Suffixes = Opening = over Plate L = 1 1/4" Hub = 2" Hub = eutral isconnect SH = Stainless Steel Hasp T = Large Hub Opening U = Large Hub over Plate Product Group esignation H = ommercial or Residential Service, Single Position (lever bypass) Jaw Quantity 4 = 4 Terminal 5 = 5 Terminal 7 = 7 Terminal mpere Rating 2 = 200 mps 3 = 320 mps Products beginning with 10 or GE will not follow the nomenclature. aximum onductor (Line & Load) 0 = 3/8" Stud onnectors 2 = #250 kcmil onnectors 3 = #350 kcmil onnectors 6 = #600 kcmil onnectors Service esign 0 = Overhead 1 = ombination Overhead/Underground 2 = Underground, Side Wired 3 = ombination, Overhead/Underground, Side Wired 3
4 Single Socket etering EP pproved Single Phase, 600V mp atalog umber Ringless Wire Range (U/L) Overhead/ Underground Line eed Range (U/L) Triplex o. of Terminals Lever Horned ypass ypass Hub Type Enclosure 3R UL & Utility pproved GES1S1TV #8-2/0 Top (1) #14-2 Y 4 Y Opening UHTRS101GE #8-2/0 Top/ottom (1) #14-2 Y 4 Y Opening GE #8-250 Top/ottom (1) #14-2 Y 4 Y Opening GE #6-350 Top/ottom (1) #14-2 Y 4 Y over Plate GES1S1JTV #8-250 Top (1) #14-2 Y 4 Y Opening GES1S1TV #8-350 Top/ottom (1) #14-2 Y 4 Y over Plate GES1S1TV #8-350 Side (1) #14-2 Y 4 Y Solid Top UHTRS202GE #8-250 Top/ottom (1) #14-2 Y 4 Y Opening UHTRS223GE #8-350 ottom (1) #14-2 Y 4 Y Solid Top UHTRS233GE #8-350 Top/ottom (1) #14-2 Y 4 Y UTH4213GE #6-350 Top/ottom (1) #14-2 Y 4 Y over Plate over Plate UHTRS202SHGE #8-250 Top/ottom (1) #14-2 Y 4 Y Opening UHTRS223SHGE #8-350 ottom (1) #14-2 Y 4 Y Solid Top GE (2) #6-350 Top/ottom (1) #14-1/0 Y 4 Y UTH4330TSHGE 1 Studs - (1) 600 or (2) 350 Large Hub over Plate Top/ottom (1) #14-1/0 Y 4 Y Large Hub Opening UTH4336TSHGE #4-600 Top/ottom (1) #14-1/0 Y 4 Y Large Hub Opening UTH4330TGE 1 Studs - (1) 600 or (2) 350 Top/ottom (1) #14-1/0 Y 4 Y Large Hub Opening UTH4336TGE #4-600 Top/ottom (1) #14-1/0 Y 4 Y Large Hub Opening G90 Steel luminum G90 Steel luminum G90 Steel UL,EP Three Phase, 600V mp atalog umber Ringless Wire Range (U/L) Overhead/ Underground Line eed Range (U/L) Triplex o. of Terminals Lever Horned ypass ypass Hub Type Enclosure 3R UTH7213TSHGE #6-350 Top/ottom (1) #14-2 Y 7 Y Large Hub Opening luminum UTH7213GE #6-350 Top/ottom (1) #14-2 Y 7 Y Opening UTH7213TGE #6-350 Top/ottom (1) #14-2 Y 7 Y Large Hub Opening UTTH7213TGE #6-350 Top/ottom (2) #14-2 Y 7 Y Large Hub Opening UTH7330TSHGE 1 Studs - (1) 600 or (2) 350 Top/ottom (1) #14-1/0 Y 7 Y Large Hub Opening UTH7336TSHGE #4-600 Top/ottom (1) #14-1/0 Y 7 Y Large Hub Opening UTH7330TGE 1 Studs - (1) 600 or (2) 350 Top/ottom (1) #14-1/0 Y 7 Y Large Hub Opening UTH7336TGE #4-600 Top/ottom (1) #14-1/0 Y 7 Y Large Hub Opening UTTH7330TGE 1 Studs - (1) 600 or (2) 350 Top/ottom (2) #14-1/0 Y 7 Y Large Hub Opening UTTH7336TGE #4-600 Top/ottom (2) #14-1/0 Y 7 Y Large Hub Opening 1 Lugs not included. This product comes with studs only. Order lugs separately, see accessories on page 10. One (1) lug per kit, order appropriate quantity needed. or example, order 3 lugs (,, ) if meter is single-phase or 4 lugs (,,, ) if meter is three-phase. G90 Steel luminum G90 Steel UL & Utility pproved UL,EP 4
5 Single Socket etering EP pproved (continued) Single or Three Phase, 600V mp 200 atalog umber Ringless Wire Range (U/L) Overhead/ Underground Line eed Range (U/L) Triplex o. of Terminals Lever ypass UTH5213GE #6-350 Top/ottom (1) #14-2 Y 5 Y UTH5213GE #6-350 Top/ottom (1) #14-2 Y 5 Y Horned ypass Hub Type Opening Opening 1 Lugs not included. This product comes with studs only. Order lugs separately, see accessories on page 10. One (1) lug per kit, order appropriate quantity needed. or example, order 3 lugs (,, ) if meter is single-phase or 4 lugs (,,, ) if meter is three-phase. Enclosure 3R luminum G90 Steel UL & Utility pproved UL,EP imensions and Enclosure Style atalog umber Height () Inches Width () Inches epth () Inches Gross Weight lbs. Enclosure Style GE GE GE GES1S1TV GES1S1JTV GES1S1TV igure GES1S1TV UTH4330TSHGE UTH4336TSHGE UTH5213GE UTH7213TSHGE UTH7330TSHGE UTH7336TSHGE UHTRS202SHGE UHTRS223SHGE igure UHTRS101GE UHTRS202GE UHTRS223GE UHTRS233GE UTH4213GE UTH4330TGE UTH4336TGE UTH5213GE igure UTH7213GE UTH7213TGE UTH7330TGE UTH7336TGE UTTH7213TGE UTTH7330TGE UTTH7336TGE
6 Single Socket etering EP pproved nockout rawings and imensions atalog umber nockout igure GE S GE G GE L L L GES1S1TV I L L L GES1S1JTV J igure igure G igure H GES1S1TV H GES1S1TV UTH4330TSHGE UTH4336TSHGE UTH5213GE UTH7213TSHGE UTH7330TSHGE V J I J E igure I igure J igure UTH7336TSHGE V UHTRS202SHGE UHTRS223SHGE O UHTRS101GE W E UHTRS202GE UHTRS223GE UHTRS233GE J E E E igure igure S igure V UTH4213GE UTH4330TGE UTH4336TGE UTH5213GE O O O UTH7213GE J J E UTH7213TGE UTH7330TGE V igure W igure igure O UTH7336TGE UTTH7213TGE UTTH7330TGE UTTH7336TGE V V V nockout imensions (inches) = 1-1/2, 2, 2-1/2 J = 1/2, 3/4, 1, 1-1/4 = 1-1/4, 1-1/2, 2, 2-1/2 = 1, 1-1/4, 1-1/2, 2, 2-1/2 = 1/2 L = 2, 2-1/2, 3, 3-1/2 = 5/16 = 2, 2-1/2, 3, 3-1/2, 4 E = 2, 2-1/2, 3 = 1, 1-1/4, 1-1/2, 2 = 1/2, 3/4 O = 1/2, 3/4, 1, 1-1/4, 1-1/2 I = 1-1/4, 1-1/2, 2 6
7 Horizontal etering EP pproved pplication Information GE s Horizontal etering products offer 600V metering solutions for strip malls and small commercial buildings requiring two to six metering locations. These products accept meters with 200 ratings and they have a compact vertical footprint. The products in this brochure meet all of the EP utility specification requirements. Specifications and eatures Single Phase Top/ottom eed UL Listed Selected items are utility approved E 3R enclosure ultiple hub opening and closure plate sizes available Hub opening in top endwall, requires use of a bolt-on hub or closing plate 1Ø, 600 Vac maximum ain lugs only End or center feed Overhead and underground service feeds 10 ki short circuit rating (or higher with utility approval) 7
8 Horizontal etering EP pproved Horizontal omenclature U H T 3R T GE Standard Prefix U = UL Labeled GE = General Electric dditional eatures = arrel Lock and Lock Guard H = Horn ypass T = ing onnector (#14-#2 U-L) Product Group esignation 2, 3, 4, 5, or 6 Position Residential Service mpere Rating 1 = 100 mps 2 = 200 mps Standard Suffixes = Opening T = Large Hub Opening aximum onductor (Line & Load) 1 = #2/0 onnectors 2 = #250 kcmil onnectors 3 = #350 kcmil onnectors 5 = #500 kcmil onnectors 9 = ual #500 kcmil onnectors Service esign 1 = ombination Overhead/Underground 3 = ombination, Overhead/Underground, Side Wired Single Phase, 600V mp Gang atalog umber Ringless eed Type Overhead/ Underground Line eed Line Wire Range Lug Size Triplex o. of Terminals Lever ypass Horned ypass Hub Type Enclosure 3R UL & Utility pproved 2 UHT2R2332TGE enter Top/ottom #8-350 Line #8-250 Load (1) #14-2 Y 4 Y Large Hub Opening 3 UHT3R2332TGE enter Top/ottom #6-350 Line #8-250 Load (1) #14-2 Y 4 Y Large Hub Opening UHT4R2352TGE enter Top/ottom 5 UHT5R2392TTGE enter Top/ottom 1/0-500 Line #8-250 Load 1/0-500 Line #8-250 Load (1) #14-1/0 Y 4 Y (1) #14-2/0 Y 4 Y Large Hub Opening (2) Large Hub Openings G90 Steel UL, EP 6 UHT6R2392TTGE enter Top/ottom 1/0-500 Line #8-250 Load (1) #14-2/0 Y 4 Y (2) Large Hub Openings 8
9 Horizontal etering EP pproved imensions and Enclosure Style atalog umber Height () Inches Width () Inches epth () Inches Gross Weight lbs. Enclosure Style Standard Pack UHT2R2332TGE UHT3R2332TGE E 1 UHT4R2352TGE H 1 UHT5R2392TTGE UHT6R2392TTGE Enclosures igure igure igure E igure H 9
10 Horizontal etering EP pproved nockout rawings and imensions atalog umber nockout igure Standard Pack UHT2R2332TGE 1 UHT3R2332TGE G 1 UHT4R2352TGE L 1 UHT5R2392TTGE 1 UHT6R2392TTGE 1 E E E E igure igure E igure E igure G E igure L nockout imensions (inches) = 1/2 = 5/16 E = 2, 2-1/2, 3 = 1/2, 3/4 = 1, 1-1/4, 1-1/2, 2, 2-1/2 10
11 Single Socket and Horizontal etering ccessories atalog umber escription RP00118GE One Lug for (2) #6-250 ables/phase RP00429GE One Lug for (1) #4-600 ables/phase or (2) 1/0-250 ables/phase RP00129GE onnector it #4-600 RP00326GE 5th Terminal it Lever ypass RP00035GE 5th Terminal it on-lever ypass RP00984GE nti-inversion lip (10 per package) GE uxiliary ontacts Enclosure G90 RP00920GE Plastic eter Socket over Plate RP00002GE olt-on over Plate, Small, 3 5/16" x 3 5/16" RP00016GE olt-on over Plate, Large, 5" x 5" RP00035GE RP00920GE Hub its atalog umber RP00003GE RP00004GE RP00005GE RP00006GE RP00007GE RP00017GE RP00018GE RP00019GE RP00020GE RP00021GE escription 1" Hub it, Small 1.25" Hub it, Small 1.5" Hub it, Small 2" Hub it, Small 2.5" Hub it, Small 2" Hub it, Large 2.5" Hub it, Large 3" Hub it, Large 3.5" Hub it, Large 4" Hub it, Large Large Hub 11
12 GE Energy onnections 41 Woodford venue Plainville, T *Indicates a trademark of the General Electric ompany and/or its affiliates. Information provided is subject to change without notice. Please verify all details with GE. ll values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. 2017, General Electric ompany and/or its affiliates. ll rights reserved ET-873
Single Socket and Horizontal Metering
G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are
More informationSingle Socket and Horizontal Metering
Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential
More informationMetering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering
Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal
More informationLoad Centers and Circuit Breakers
Midwest lectric Products Load enters and ircuit reakers MLM4020U TQL2140 TQL11202 TQL1115 TQL2120T Midwest Load enters pplication Information Midwest load centers lower your costs by making installation
More information5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets
.1 Metering Products Product Description Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac All Eaton sockets are rated All single meter sockets are 600 Vac maximum and either UL labeled and are
More information5.11. Metering Products. Contents Description Systems for Residential and Commercial
3MM, 37MM, 3SS and 37SS Main Tenant ircuit reakers V2/EHD2100 ontents Description Systems for Residential and ommercial pplications............................ Meter Packs.............................
More informationEquipment. Metering. Metering Equipment 1. Contents
1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................
More informationEquipment. Metering. Metering Equipment 1. Contents
1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................
More informationGE Industrial Solutions. From houses to high-rises GE Residential products and solutions
ndustrial Solutions rom houses to high-rises Residential products and solutions More choices. exclusive options. continues to provide products and solutions for your residential installations that are
More informationGroup Metering & Meter Breakers. Group Metering & Meter Breakers 5-1. Contents
Group Metering & Meter reakers - July Group Metering & Meter reakers Contents Description Page Single Meter Sockets............................................ - Group Metering.................................................
More informationMetering NEED. Meter Sockets. Product Description
Meter Sockets Meter Sockets Single Position (Ring, Ringless and Bypass)........ - Multiple Position Without Tenant Main Breakers.......... - Accessories.......................... -7 Meter Packs (All-in-Ones)
More informationMidwest Electric Products. AC Disconnects
Midwest Electric Products isconnects Midwest Electric Products pplication Information rticle 440 of the National Electrical ode applies to electric motor-driven air conditioning and refrigerating equipment
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More information4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering
Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More information5.10. Metering Products. Contents. House Panels. Meter Breakers
Metering Products Meter reakers. Contents Description Residential Meter reakers.................. on-euserc Combination Service Entrance Devices 0 00 Styles.................. Meets EUSERC Requirements
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac
More informationEZ Meter-Pak Meter Centers
NEMA 3 onstruction Vac Maximum, for use on A systems, suitable for use as ervice Equipment. tility ompany equirements: eview local utility requirements to ensure that metering equipment meets their standards.
More informationModular Metering Section 2
Mini Mod III Nomenclature...-3 Photos...-4 Ring -Type and Ringless...-5 Ring -Type and Ringless - MG pproved 5 & 00 Sockets...-6 Tenant Main reakers for Mini Mod Product Family...-7 Factory Installed Lug
More informationLoad Centers
Siemens would like to welcome the urray Electrical Products into the Speedfax. The urray Electrical Products catalog and Siemens Speedfax has been combined for our customer s convienience. ll of the urray-branded
More informationFor vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed
Multiple Vertical APPLICATION For vertical multi-meter installations 1-6 meter positions esigned to receive watthour meters that meet ANSI C12.10 Overhead or underground feed CONSTRUCTION Type 3R construction
More informationModular Metering Application Guide
GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac
More informationMultiple Metering, Horizontal Gang - Non Lever Bypass
Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground
More informationMidwest Electric Products. Temporary Power
Midwest Electric roducts Temporary ower Midwest Electric roducts Temporary ower Midwest Electric provides the temporary power needed by construction trades prior to permanent service equipment installation.
More informationMeter Mains - With Optional MCC Bypass
Meter Mains - With Optional MCC ypass pplication Combination meter/main with optional manual circuit closing (link type) bypass Factory installed breaker Receive SI C12.10 watthour meters Surface mount
More informationGround Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB
lamps Waterpipe Ground lamps Waterpipe Ground lamps Waterpipe Ground lamps 2-T Ground Wire Size Water Pipe Size 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, #2 WG 4 2-1/2
More information1.5 INCH W X 2.91 INCH D X 3 INCH H
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 ax: 936-560-4685 Q0230 QO230 2P-120/240V-30 Square ompany atalog Number Manufacturer escription Weight per unit Product ategory Q0230 Square
More informationMultiple Metering, Vertical Gang
Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or
More informationTHERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS
THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.
More informationTHERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS
THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.
More informationFor the most up-to-date information
www.square.com or the most up-to-date information Thermal-magnetic Molded ase ircuit reakers, 2 mpere rame lass 5,, 734, 8 IL3 JL 3-pole circuit breaker -frame, Thermal-magnetic ( Vac) mpere Magnetic Trip
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More informationAluminum Mechanical Lugs
luminum Mechanical ugs MNI INUSTRI ONNTORS One- and Two-onductor luminum ugs Suitable for use with either copper or aluminum conductors Manufactured from high strength 6061-T6 aluminum alloy lectroplated
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
Catalog Number System For illustrative purposes only. Circuit reaker Selection Guide T H L 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC L = Plug-in
More informationOpen, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts
0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,
More informationFuse Holders. General Information: Fuse Clips: Phone: Fax: Web:
eneral Information: Marathon has been manufacturing quality fuse holders for over 40 years. The key word is quality. It is incorporated into every Marathon fuse holder, right along with design. The product
More informationCable & Wire Management
able & ire Management able & ire Management Lay-In ireway Type 1 Screw over... 8-14 Lay-In ireway Type 1 Quick-onnect inge over... 15-20 Lay-In ireway Type 3R EnviroShield... 21-24 Lay-In ireway Type 12...
More informationQwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip. Discount Schedule DE2A
OR URRNT INORMTION I I Two-wire SWN New! 2P I Three-wire SWN QO With Shunt Trip K Key Operated QO and Miniature ircuit reakers QO rc-ault ircuit reaker QO arc-fault circuit breakers provide branch feeder
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION
More informationTHERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS
THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.
More informationNQOD Circuit Breaker Panelboards
NQOD Circuit reaker Panelboards Class 1630 CONTENTS Description Page pplication Data..................................................... 3 Typical Wiring Diagrams..............................................
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationMidwest Electric Products. Safety Switches Rugged, reliable and easy to install
Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,
More informationMidwest Electric Products. General Products Catalog
Midwest lectric roducts eneral roducts atalog Midwest lectric roducts eneral roducts atalog Markets ontents Introduction 2 5 ervice quipment 6 29 Disconnects 37 Temporary ower 38 49 ower Outlets 50 63
More informationMeter Mounting Equipment Wisconsin Area
Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More informationWisconsin Area Catalog
Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More information4-Way, 5-Port, 2 & 3-Position Solenoid and Remote Pilot 1/2" & 3/4" Ports. Technical & Service Data. Pneumatic
atalog VL-UTO-/US (Revised 6/0/0) pplication & Model Selection S utomotive Subbase Valves -Way, -ort, & -osition Solenoid and Remote ilot /" & /" orts pplication ual pressure or diverter valve operation
More informationModular Metering Construction Details
GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single
More informationMP Meter-Pak Meter Centers
Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More information4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors
.2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in
More informationMicrolectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units
Microlectric CO Series Meter sockets A complete family of combination meter sockets and breaker units Outdoor, above-ground main breaker access increases safety Table of Contents Introduction... 3 Microlectric
More informationEDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards
-P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit
More informationLoad Centers and Circuit Breakers. Section 1.
Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in
More informationCable & Wire Management
Type 1 Screw over... 8-14 Type 1 Quick-onnect inge over... 15-20 Type 3R nviroshield... 21-24 Type 12... 25-31 eed-through Wireway Type 12... 32-35 eed-through Wireway Type 4X... 36-39 Wiring Trough Type
More informationU075CTL A Surface 50/30/20GFCI Twin Lugs
3804 South Street 75964-7263, TX Nacogdoches hone: 936-569-794 Fax: 936-560-4685 llenwatson@elliottelectric.com U075TL00 00 Surface 50/30/20GFI Twin Lugs Midwest Electric roducts atalog Number Manufacturer
More informationQO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories
QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.
More informationTemporary Power Outlet Panels
Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationSection A Busway
Section 8 800 5000 usway usway atalog Numbering System Section 8 800 5000 usway usway atalog Numbering System atalog numbers are composed of two basic parts the prefix (as below), plus the suffix of each
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationREC Municipal Meter Mounting Equipment
REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationTenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering
for GE Meter Mod * III Modular Metering Your guide to GE s GE tenant main circuit breakers are typically used in residential and light commercial group metering applications. This product category offers
More informationQO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers
QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for
More informationClass 320 Metering. Class 320 Metering. Meter Mounting Equipment
Single Meter Sockets, Without ypass -............................ 57-58 Meter Mains, With Optional MCC ypass -......................... 59-60 Meter Main Load Centers, With Optional MCC ypass -..........
More informationIndiana Meter Mounting Equipment
Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationJune 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]
7-2 Lighting ontactors Open ontrol June 2005 N5 lectrically Held Vol. 2, Ref. No. [09] ontents eatures Instructional Leaflets 7 escription Page lectrically Held Product escription....... 7-2 pplication
More informationInstrument Rated Metering Equipment
Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions
More informationDisconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494
Technical ata isconnect Switch and ircuit reaker Mechanism Specifications ulletin Number 1494 Topic Page 1494U isconnect Switch Specifications 2 1494, 1494F, 1494G, 1494R, 1494V isconnect Switch Specifications
More information28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description
.1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is
More informationModular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families
Modular Metering Stock Selection Guide Meter Mod * III and Mini Mod * III Product Families Table of Contents Page No. Nomenclature 3 Main Breaker Module, Single-Phase, 3 Wire, 0/40 Vac 4 Main Breaker Module,
More informationIsys Micro Series. Valve Products. Operating information. Material specifications. Pilot configuration
atalog 000-3US The Valve System incorporates a space saving back to back valve mounting design, and achieves flow rates of 0.35 v per valve with valves having a combined width of mm. This plug-in valve
More informationMEG Approval Meter Equipment Group
MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationCT Metering. CT Metering. Meter Mounting Equipment
Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination
More informationClass 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac)
MINITUR N MOL S IRUIT RKRS PowerPact ircuit reaker JL 3P ircuit reaker QL 2P 0 250 QL 3P 0 250 Tale.46: mpere - and Q-rame ircuit reakers lass 034, 0500 / Refer to atalogs: 034T0201, 0500T902 PowerPact
More informationtot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,
' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *
More informationNote: Supply from an underground network often requires use of stud type connector. Consult your local utility.
BQ2 Series 200 A 600 V; Standard Enclosure Conductor range: 6 AWG 250 kcmil Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Primarily
More informationR-Rated medium voltage fuses for motor circuit protection
Technical ata 6001 Supersedes September 2017 Features and benefits escription: Indoor/enclosure, R-Rated medium voltage, current-limiting fuses for motor circuit protection. urrent-limiting R-Rated fuses
More informationNew England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that
More informationNQOD Circuit Breaker Panelboards
Catalog 2005 Class 1630 CONTENTS Description..............................................Page PPLICTION DT.......................................... 3 TYPICL WIRING DIGRMS.................................
More informationMeter Centers Meter Mounting Devices
Meter Mounting Devices General General Information Materials: 16 gauge, galvanized steel, G-90 Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless
More informationLoad Centers and Circuit Breakers. Section 1.
Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationSection 1. Load Centers and Circuit Breakers.
Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits... 1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in
More informationHeavy Duty Safety Switches
eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................
More informationPump Panels Type 3R Enclosure
Type R Enclosure Product Family Overview June 6 Product escription The utler-hammer Pump ontrollers from Eaton s electrical business are combination starters with accessories and modifications designed
More informationMeter Mounting Equipment. Northern Indiana Public Service Co.
Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop
More informationMeter Mounting Equipment DTE Energy Area
Meter Mounting Equipment DTE Energy Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationGE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary.
GE Industrial Solutions EntellEon * Low-Voltage Power Panel Simple. Responsive. Revolutionary. Introducing EntellEon A More Versatile Alternative to Traditional Power Panels EntellEon, the new low-voltage
More informationBulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)
Installation Instructions ulletin 1494F, 60, Fixed-epth isconnect Switch (at 1494F-N30; 1494F-N60; 1494F-N100; Series ) WRNING: To prevent electrical shock, disconnect from power source before installing
More informationPower Mod. Introduction.
Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination
More information