T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

Size: px
Start display at page:

Download "T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes."

Transcription

1 Catalog Number System For illustrative purposes only. Circuit reaker Selection Guide T H L 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC L = Plug-in = 20/240Vac GF = pole HH = 22kIC P = 2 Plug-In 2 = 240V GFCI = 65kIC = olt-on Omit for THP GF = 2-pole breakers GFCI (all 20/240Vac) F = FCI Recommendations based on standard conditions. Installation must conform to all local and national codes. pplication Selection Recommended Circuit reaker ppliance verage atts Volts mps ire Size 2-inch -inch ir Conditioner Up to,000 TU #2 THP20 THL20 Up to 23,000 TU #2 THP220 THL220 Up to 30,000 TU #0 THP230 THL230 ttic Fan Up to 2 HP #4 THP5 THL5 Up to HP #2 THP20 THL20 athroom or Outdoor Receptacles #4 THL5GF #2 THL20GF edroom Receptacles (for maximum #4 THL5F safety; required by 2002 NEC) #2 THL20F ranch Circuits (Indoor Receptacles) #4 THP5 THL #2 THP20 THL20 Clothes ryer #0 THP230 THL230 ishwasher #2 THP20 THL20 oorbell Transformer #4 THP5 THL5 Electric Heater #2 THP20 THL20 Electric Range #6 THP250 THL250 Electric elder (240V; over 0 away) #6 THP250 THL250 Fixed Lighting #4 THP5 THL5 Garbage isposal #4 THP20 THL20 Hot Tub or Spa #8 THL240GF #8 THL250GF Hot ater Heater #0 THP230 THL230 Motors (Single Phase) Up to 2 HP #4 THP5 THL5 2 to HP #2 THP20 THL20 to 2 HP #4 THP25 THL25 2 to 3 HP #0 THP230 THL230 Refrigerator or Freezer #4 THP5 THL5 Sump Pump Up to 2 HP #4 THP5 THL5 2 to HP #2 THP20 THL20 [ RELIILITY N ECONOMY. ] Line Circuit reakers 5 ashing Machine #4 THP5 THL5 ell Pump Up to 2 HP #2 THP20 THL #4 THP25 THL25 2 to HP #0 THP30 THL #2 THP220 THL #8 THP240 THL240 Special Safety Circuit Protection Products Included among GE s circuit protection products are several that add the extra measure of safety that is increasingly important to today s new home buyers and remodelers. See page 8 for details. Safety Need Safety Solution mp Rating Ground fault protection for circuits supplying power to outdoor, bathroom, kitchen, garage and spa area receptacles. GFCIs (ground fault circuit interrupters) 5-50 Maximum protection against fires through detection and interruption of arcing caused by damaged wire insulation or extension cords. The 2002 NEC FCIs (arc fault will require this protection in bedroom circuits. circuit interrupters) 5-20 hole house protection of sensitive electronic equipment computers, fax machines, televisions, stereos, VCRs from electrical surges. Surge arrester N

2 H I G H E R U L I T Y. L O E R I N S T L L E C O S T. H I G H E R U L I T Y. L O E R I N S T L L E C O S T [ HIGHER ULITY. LOER INSTLLE COST.] PowerMark Gold Load Centers 0 Packaging features comprehensive selection and application data. Fronts are packed in inner cartons for added protection during shipment and at the job site. complete family of meter socket load centers ring style and ringless, wide and narrow, meter mains, farm panels and more deliver specialized solutions for special situations. Main lug load centers offer an economical solution for subpanels and similar applications. ll main lug units 25 and above convert easily to main breaker. GE s residential load centers reach into commercial applications as well, with riser panels, auxiliary gutters, three-phase units with standard 22kIC ratings, and all the accessories needed to complete the job. ll PowerMark Gold load centers are designed and built for faster installation and more dependable performance. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 00% neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/robertson screws speed wiring. ll holes are rated for 4-4 wire. 00% rated split neutral on each side. Load centers accept Line circuit breakers, including GE s exclusive 2 THPs. The PowerMark Gold line includes a wide range of outdoor as well as indoor units. ccessories & Options oor lock & handle Equipment ground kits Sub-feed & feedthru lugs Front filler plates Handle lock & ties Hardware kits Main breaker retainers Neutral kits Universal raintight hubs

3 Catalog Number System For illustrative purposes only. Load Center Selection Guide Main reaker Load Centers Main mp reaker Rating (mps) Rating THL 2 THP Total -pole ase Cu l -pole 2-pole -pole 2-pole Spaces Suffix 2 Suffix TM860 F,S CUGEN TM20 C,R CU TM200 C,R CU TM320 C CU TM242 C,R CU TM22 C,R CU TM62 C CU TM85 R CUFL TM245 C,R CU TM325 C,R CU TM65 C,R CU TM820 R CUFL TM620 C CU TM2020 C,R CU TM3220 C,R CU TM4020 C,R CU Convertible Load Centers Main mp reaker Rating (mps) Rating THL 2 THP Total -pole ase Cu l -pole 2-pole -pole 2-pole Spaces Suffix 2 Suffix TLM62 S,F CU, TLM82 S,F CU, TLM242 C,R CU TLM22 C,R CU TLM62 C CU TLM205 C CU TLM245 C,R CU TLM620 C,R CU TLM2020 C,R CU TLM3220 C CU TLM4020 C,R CU Main Lug Load Centers Main mp reaker Rating (mps) Rating THL 2 THP Total -pole ase Cu l -pole 2-pole -pole 2-pole Spaces Suffix 2 Suffix TL240 C,R CU TL270 C,R CU T M C CU GE Identification Type Maximum Number Insert for 3-phase, us mpere Rating Enclosure Type Insert for Insert for Specials of Spaces 4-wire Load Centers PowerMark Gold M = Main reaker = 00 C = Combination Flush CU = Copper us G or T = Factory Installed L = Main Lug 2 = 25 and Surface, Indoor Ground ar LM = Convertible 5 = 50 F = Flush = ottom Feed Main reaker PL = Main Lug, 20 = 200 S = Surface FL = Factory installed Thermoplastic 22 = 225 R = Outdoor Feed-thru Lugs Enclosure 40 = 40 = Optional door for = 60 circuit indoor panels. (oors 70 = 70 are standard on all other units.) (For details on these and other load centers, see the selection tables on the following pages.) TPL42 C,R TL42 C, R [ HIGHER ULITY. LOER INSTLLE COST. ] PowerMark Gold Load Centers Catalog number is constructed by adding Suffix and Suffix 2 to ase Catalog Number. 2 F = Flush mount indoor S = Surface mount C = Combination flush/surface mount indoor R, R = Outdoor 3 CU = Copper bus CUFL = Copper bus, feed-thru lugs CUGEN = Copper bus, generator panel with dual main circuit breakers = Optional door for 6- and 8-circuit indoor panels (door standard on outdoor panels)

4 S E L E C T I O N T L E S. S E L E C T I O N T L E S. S E L E C T I O N T L E S. S E L E C T I O N T L E S. [ SELECTION TLES. ] PowerMark Gold & Plus Load Centers UL Listed (Panelboards No. 67) 60 C/75 C Conductor Rating Indoor Fronts Combination Surface/Flush Suitable for Use as Service Entrance Equipment hen Installed in ccordance with the National Electrical Code 22kIC RMS Symmetrical, Except here Noted Main Lug & Convertible Load Centers Single-phase, Three-wire, 20/240 Volts ac, Top Feed Factory Installed Main Lugs (TLM units convertible to main breaker) PowerMark Plus catalog numbers shown in italics 2 Equipment Indoor Type Enclosure23 Outdoor Type 3R Enclosure3 Main Main ire Size Ground Kit mpere THL Total ox No. ox No. G/ kcmil Order Separately 2 THP Rating -pole See See Cu-l See Page 6 p 2p p 2p Spaces Page 24 Page TL240SCU4 TL240RCU R 4-4 TGK TL270SCU4 TL270RCU R 6-3 TGK TL42C➄ 2 TL42R➅ R TGL TL42CT➄8 2 TL42RT➅ R TGL Installed TL42R2➅ R -2/0 TGL TPL42C➄7 2 TPL42R➅7 R TGL TPL42CT➄ 2 TPL42RT➅8 R TGL Installed TLM62FCU, SCU0 3, 3 TLM62RCU0 R2 TGK TLM82FCU, SCU90 3, 3 TLM82RCU0 R2 TGK TLM22CCU 4 TLM22RCU R3 TGL TLM22CCUG 4 TGK24 Installed 6-2/ TLM62CCU 4 TGK2 or TGK TLM242CCU 7 TLM242RCU R4 TGK2 or TGK TLM205CCU 8 TGK32-3/0 (Cu) 2-3/0 (l) TLM245CCU 9 TLM245RCU R6 TGK24 or TGK TLM220RCU R5 TGK TLM620CCU 8 TLM620RCU R5 TGK TLM620CCUG 8 TGK32 Installed TLM2020CCU 9 TLM2020RCU R6-250 (Cu) 2/0-250 (l) TGK24 or TGK TLM2020CCUG 9 TGK42 Installed TLM3220CCU 2 TGK TLM4020CCU 3 TLM4020RCU R8 TGK TLM4222CCU 4 TLM4222RCU R8-300 (Cu) 2/0-300 (l) TGK TL2440F,S 6 TL2440R R9 (2) TGL2 (2) 2/ TL4240F,S 2 6 TL4240R 2 R9 (2) TGL TL4260F,S 2 7 TL4260R 2 R9 (2) (Cu) (2) (l) (2) TGL circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down. For bottom feed door handle, see page amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately (see page 7). 3 TPL load center enclosures are thermoplastic; TL and TLM load center enclosures are galvanized steel. 4 No door. ➄ No door, 0kIC. 6 0 kic. 7 Maximum branch or main circuit breaker rating: 90 amp with Cu, 70 amp with l amp maximum branch capacity. 9 FCU indicates flush mount enclosure; SCU indicates surface mount enclosure. dd to catalog number for optional door (example: TLM62SCU). 0 For main breaker, order THLRK2 retainer kit plus 2-pole circuit breaker. See page 7. For main breaker, order TMH000. lso order 2-pole THL, THHL or TL circuit breaker. See page 6. 2 Not suitable for use as service entrance equipment.

5 imensions (in inches) ox No. idth Height epth R R R R R R R R R R R R R [ IMENSIONS N KNOCKOUTS. ] PowerMark Gold & Plus Load Centers Outdoor Enclosures Knockouts Symbol C E F G H J K L M N P R S T U V Y Z CC Conduit Size in Inches Mounting provided for universal Hubs HU [ IMENSIONS N KNOCKOUTS. ] PowerMark Gold & Plus Load Centers ox R ox R2 G ox R K 25 R K U R U H ox R3, R4, R5, R6, R7 J ox R8 ox R9 ox R0, R

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac

More information

Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

Section 1. Load Centers and Circuit Breakers.  Section Updated 11 / 2014 Section Updated 11 / 2014 Q-Line Circuit Breakers Product Features and Benefits...1-2 PowerMark Gold Load Centers Product Features and Benefits...1-3 PowerMark Gold and Plus Load Centers Product Number

More information

Residential. Section 1.

Residential. Section 1. Load enters Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in ircuit reakers...1-5

More information

Load Centers and Circuit Breakers

Load Centers and Circuit Breakers Midwest lectric Products Load enters and ircuit reakers MLM4020U TQL2140 TQL11202 TQL1115 TQL2120T Midwest Load enters pplication Information Midwest load centers lower your costs by making installation

More information

Load Centers and Circuit Breakers. Section 1.

Load Centers and Circuit Breakers. Section 1. Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in

More information

Section 1. Load Centers and Circuit Breakers.

Section 1. Load Centers and Circuit Breakers. Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits... 1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Full line. Full service. Full value. GE Residential Products

Full line. Full service. Full value. GE Residential Products Full line. Full service. Full value. GE Residential Products [ ONTENTS] Full line, full service, full value................................. 1 Q Line circuit breakers........................................

More information

Load Centers and Circuit Breakers. Section 1.

Load Centers and Circuit Breakers. Section 1. Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

THQL1120AF2 THQL1120AF2 Arc Fault BRKR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Load Centers

Load Centers Siemens would like to welcome the urray Electrical Products into the Speedfax. The urray Electrical Products catalog and Siemens Speedfax has been combined for our customer s convienience. ll of the urray-branded

More information

Main Wire Size AWG/kcmil. Product Catalog # UPC Code QOM22225NS

Main Wire Size AWG/kcmil. Product Catalog # UPC Code QOM22225NS QO Load Centers > Catalog umber uide QO 1 8 16 M 100 T FT C CP Position 1 rand QO = QO HOM = Homeline Position 2 Phases Only applies to QO lank or 1 = ingle 3 = Three Position 3 paces Maximum number of

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

Contents. 4 Loadcentres

Contents. 4 Loadcentres POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ

More information

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant

More information

NQOD Circuit Breaker Panelboards

NQOD Circuit Breaker Panelboards NQOD Circuit reaker Panelboards Class 1630 CONTENTS Description Page pplication Data..................................................... 3 Typical Wiring Diagrams..............................................

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Installing a Downstream Distribution Panelboard

Installing a Downstream Distribution Panelboard Job Sheet 5 Installing a Downstream Distribution Panelboard OBJECTIVE To install a downstream distribution panelboard (DDP) on the Mobile Workstation. To mechanically and electrically connect the DDP to

More information

Retail Reference Guide

Retail Reference Guide www.usa.siemens.com/retail Retail Reference Guide Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI) uses advanced electronic technology

More information

Learning Module 10: Loadcenters. 101 Basic Series

Learning Module 10: Loadcenters. 101 Basic Series Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard A fusible panelboards Supersedes July 2018 Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications... 2-3 Enclosure types and voltages/systems.... 4 using, main and feed-through

More information

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application Product Offering and Specificaton Guide Application Main lug loadcentre, b Phase 3 W /V, to 0A, / - 0/80 circuits b 3 Phase W /8V, 00 to 5A, - circuits Main Breaker loadcentre, b Phase 3 W /V, to 0A, /

More information

Single- and Three-Phase Through 600 A. Factory Options SUR = Factory integrated surge. Number of 1-Inch (25.4 mm) Spaces. Maximum Number of Circuits

Single- and Three-Phase Through 600 A. Factory Options SUR = Factory integrated surge. Number of 1-Inch (25.4 mm) Spaces. Maximum Number of Circuits Loadcenters and Circuit reakers Type R Loadcenters and Circuit reakers.2 Standards and Certifications UL Listings ll aton Type R loadcenters are listed under UL File 52977 except the 2 8 circuit loadcenters,

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Section 8 Stab-lok Circuit Breakers

Section 8 Stab-lok Circuit Breakers Section 8 Stab-lok Circuit Breakers Stab-lok easier to work with and faster to install Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company

More information

Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard A fusible panelboards USSMNN Supersedes December 2015 SERIES Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications.... 2-3 Enclosure types and voltages/systems.... 4 using, main

More information

NQOD Circuit Breaker Panelboards

NQOD Circuit Breaker Panelboards Catalog 2005 Class 1630 CONTENTS Description..............................................Page PPLICTION DT.......................................... 3 TYPICL WIRING DIGRMS.................................

More information

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 WireGuide Load Centers and Breakers -4 PL Series Load Centers Features

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Retail Products Catalog

Retail Products Catalog Retail Products Catalog www.schneider-electric.us Table of Contents Overview bout Us...4 Product Definitions Types of Circuit Breakers, Residential Load Centers & other Electrical Devices...6 QO Product

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR

More information

Section 2 HomeLine Loadcentres

Section 2 HomeLine Loadcentres Section 2 HomeLine Loadcentres Features that Outclass the Competition The quality you expect from Schneider Electric, the industry leader, is built into all HomeLine loadcentres. One example is our exclusive

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS MANUAL TRANSFER SWITCHES FROM 0 Residential Wattage Requirements Appliance Running Watts Add watts for starting Furnace blower, gas or fuel 1/8 hp 300 500 1/8 hp

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast

Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast 1.Question: An add on unit for a hydromassage bathtub consists of a small 1-gallon water heater

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Product Selection. 2 Circuits 40 and 70 Amperes 4 and 8 Circuits 125 Amperes 2 Circuits 125 Amperes. Outdoor. Box Size. Type of Trim (Included)

Product Selection. 2 Circuits 40 and 70 Amperes 4 and 8 Circuits 125 Amperes 2 Circuits 125 Amperes. Outdoor. Box Size. Type of Trim (Included) January 00 oadcenters & ircuit reakers H oadcenters & ircuit reakers -11 ircuits 0 and 0 s and ircuits 1 s ircuits 1 s Flush (No oor) Flush (No oor) Flush Single-Phase ug oadcenters Table -. Single-Phase

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering GE Energy onnections Single Socket and Horizontal etering EP pproved Single Socket etering EP pproved pplication Information GE s Single Socket etering products are designed for residential use. They are

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

1.3. Loadcenters and Circuit Breakers. Contents Description Standards and Certifications... Product Selection...

1.3. Loadcenters and Circuit Breakers. Contents Description Standards and Certifications... Product Selection... OEM Loadcenters Contents s and Certiications................. Product Selection......................... Page V-T-83 V-T-83 Product s a leader in the electrical distribution equipment business, Eaton has

More information

Pow-R-Line 3E Panelboard

Pow-R-Line 3E Panelboard This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

CON EDISON EQUIPMENT

CON EDISON EQUIPMENT CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200

More information

GE Industrial Solutions. From houses to high-rises GE Residential products and solutions

GE Industrial Solutions. From houses to high-rises GE Residential products and solutions ndustrial Solutions rom houses to high-rises Residential products and solutions More choices. exclusive options. continues to provide products and solutions for your residential installations that are

More information

Circuit Breaker Accessories BREQS125 BRHDK125

Circuit Breaker Accessories BREQS125 BRHDK125 anuary 2008 Loadcenters & ircuit reakers Type R Loadcenters & ircuit reakers ircuit reaker ccessories -75 ircuit reaker ccessories TS LW2 RLW2 RQS25 TOW (nstalled) MPL (nstalled) RQLW LW RK25 RML Table

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses mp-trap 2000 Fuses For Type 2, No Damage circuit protection in all the configurations you need. Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

For the most up-to-date information

For the most up-to-date information www.square.com or the most up-to-date information Thermal-magnetic Molded ase ircuit reakers, 2 mpere rame lass 5,, 734, 8 IL3 JL 3-pole circuit breaker -frame, Thermal-magnetic ( Vac) mpere Magnetic Trip

More information

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages FILE: Distribution Product Catalog!!IERVICEB.aJC Power Outlet Panels CONTENTS Description Class Pages Application Data.......................... 1140........ 36 Dimensions................................

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

5.10. Metering Products. Contents. House Panels. Meter Breakers

5.10. Metering Products. Contents. House Panels. Meter Breakers Metering Products Meter reakers. Contents Description Residential Meter reakers.................. on-euserc Combination Service Entrance Devices 0 00 Styles.................. Meets EUSERC Requirements

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work GE Energy Industrial Solutions EV Charging Station Application Guide imagination at work EV Charging Station Introduction The GE EV Charging Station offers Level II charging capable of reducing charge

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

QO and HOMELINE Circuit Breaker Load Centers and Enclosures

QO and HOMELINE Circuit Breaker Load Centers and Enclosures QO and HOMELIE Circuit Breaker Load Centers and Enclosures Class 1130, 1131, and 1170 COTET chneider Electric Brands Description Page QO Circuit Breaker Load Centers Class 1130............................

More information

5.11. Metering Products. Contents Description Systems for Residential and Commercial

5.11. Metering Products. Contents Description Systems for Residential and Commercial 3MM, 37MM, 3SS and 37SS Main Tenant ircuit reakers V2/EHD2100 ontents Description Systems for Residential and ommercial pplications............................ Meter Packs.............................

More information

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards -P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit

More information

U075CTL A Surface 50/30/20GFCI Twin Lugs

U075CTL A Surface 50/30/20GFCI Twin Lugs 3804 South Street 75964-7263, TX Nacogdoches hone: 936-569-794 Fax: 936-560-4685 llenwatson@elliottelectric.com U075TL00 00 Surface 50/30/20GFI Twin Lugs Midwest Electric roducts atalog Number Manufacturer

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I recently installed a 45-KVA transformer, 480-volt primary

More information

22.000A IR. Catalog Number. Price $

22.000A IR. Catalog Number. Price $ Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description .5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

Midwest Electric Products. AC Disconnects

Midwest Electric Products. AC Disconnects Midwest Electric Products isconnects Midwest Electric Products pplication Information rticle 440 of the National Electrical ode applies to electric motor-driven air conditioning and refrigerating equipment

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to

More information

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

High Speed Fuses. Section Contents Page

High Speed Fuses. Section Contents Page Section Contents Page General pplications.......................1-13 North merican fuses & accessories...........1-11 DFJ - High speed Class J fuse.................. 15 Square ody fuses & accessories............

More information

Air Conditioning Disconnects

Air Conditioning Disconnects .1 Product Description............................................. 2 Application Description........................................... 2 Features, Benefits and Functions...................................

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

Quik-Spec. Section Contents

Quik-Spec. Section Contents Section Contents Page Quik-Spec Coordination Panel Boards......... 238-239 Quik-Spec Power Module Switches and Panels.. 240-241 Quik-Spec DC Safety Switches.................. 242 Quik-Spec Solar Combiner

More information