1 atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac F = pole = 22kI Q = 2 lug-in 2 = 240V FI = 65kI Q = olt-on Omit for TQ F = 2-pole breakers FI (all 20/240Vac) F = FI Recommendations based on standard conditions. Installation must conform to all local and national codes. pplication election Recommended ircuit reaker ppliance verage atts Volts mps ire ize 2-inch -inch ir onditioner Up to,000 TU #2 TQ20 TQL20 Up to 23,000 TU #2 TQ220 TQL220 Up to 30,000 TU #0 TQ230 TQL230 ttic Fan Up to #4 TQ5 TQL5 Up to #2 TQ20 TQL20 athroom or Outdoor Receptacles #4 TQL5F #2 TQL20F edroom Receptacles (for maximum #4 TQL5F safety; required by 2002 NE) #2 TQL20F ranch ircuits (Indoor Receptacles) #4 TQ5 TQL #2 TQ20 TQL20 lothes ryer #0 TQ230 TQL230 ishwasher #2 TQ20 TQL20 oorbell Transformer #4 TQ5 TQL5 Electric eater #2 TQ20 TQL20 Electric Range #6 TQ250 TQL250 Electric elder (240V; over 0 away) #6 TQ250 TQL250 Fixed Lighting #4 TQ5 TQL5 arbage isposal #4 TQ20 TQL20 ot Tub or pa #8 TQL240F #8 TQL250F ot ater eater #0 TQ230 TQL230 Motors (ingle hase) Up to #4 TQ5 TQL5 2 to #2 TQ20 TQL20 to #4 TQ25 TQL25 2 to #0 TQ230 TQL230 Refrigerator or Freezer #4 TQ5 TQL5 ump ump Up to #4 TQ5 TQL5 2 to #2 TQ20 TQL20 [ RELIILITY N EONOMY. ] Q Line ircuit reakers 5 ashing Machine #4 TQ5 TQL5 ell ump Up to #2 TQ20 TQL #4 TQ25 TQL25 2 to #0 TQ30 TQL #2 TQ220 TQL #8 TQ240 TQL240 pecial afety ircuit rotection roducts Included among E s circuit protection products are several that add the extra measure of safety that is increasingly important to today s new home buyers and remodelers. ee page 8 for details. afety Need afety olution mp Rating round fault protection for circuits supplying power to outdoor, bathroom, kitchen, garage and spa area receptacles. FIs (ground fault circuit interrupters) 5-50 Maximum protection against fires through detection and interruption of arcing caused by damaged wire insulation or extension cords. The 2002 NE FIs (arc fault will require this protection in bedroom circuits. circuit interrupters) 5-20 hole house protection of sensitive electronic equipment computers, fax machines, televisions, stereos, VRs from electrical surges. urge arrester N
2 I E R Q U L I T Y. L O E R I N T L L E O T. I E R Q U L I T Y. L O E R I N T L L E O T [ IER QULITY. LOER INTLLE OT.] owermark old Load enters 0 ackaging features comprehensive selection and application data. Fronts are packed in inner cartons for added protection during shipment and at the job site. complete family of meter socket load centers ring style and ringless, wide and narrow, meter mains, farm panels and more deliver specialized solutions for special situations. Main lug load centers offer an economical solution for subpanels and similar applications. ll main lug units 25 and above convert easily to main breaker. E s residential load centers reach into commercial applications as well, with riser panels, auxiliary gutters, three-phase units with standard 22kI ratings, and all the accessories needed to complete the job. ll owermark old load centers are designed and built for faster installation and more dependable performance. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 00% neutral terminations. turdy copper bus and galvanized box increase durability and reliability. ombination slotted/robertson screws speed wiring. ll holes are rated for 4-4 wire. 00% rated split neutral on each side. Load centers accept Q Line circuit breakers, including E s exclusive 2 TQs. The owermark old line includes a wide range of outdoor as well as indoor units. ccessories & Options oor lock & handle Equipment ground kits ub-feed & feedthru lugs Front filler plates andle lock & ties ardware kits Main breaker retainers Neutral kits Universal raintight hubs
3 atalog Number ystem For illustrative purposes only. Load enter election uide Main reaker Load enters Max. ranch Maximum paces Main mp reaker Rating (mps) Rating TQL 2 TQ Total -pole ase u l -pole 2-pole -pole 2-pole paces at. No. at. No. uffix 2 uffix TM860 F, UEN TM20,R U TM200,R U TM320 U TM242,R U TM22,R U TM62 U TM85 R UFL TM245,R U TM325,R U TM65,R U TM820 R UFL TM620 U TM2020,R U TM3220,R U TM4020,R U onvertible Load enters Max. ranch Main mp reaker Rating (mps) Maximum paces at. No. Rating TQL 2 TQ Total -pole ase u l -pole 2-pole -pole 2-pole paces at. No. uffix 2 uffix TLM62,F U, TLM82,F U, TLM242,R U TLM22,R U TLM62 U TLM205 U TLM245,R U TLM620,R U TLM2020,R U TLM3220 U TLM4020,R U Main Lug Load enters Max. ranch Main mp reaker Rating (mps) Maximum paces at. No. Rating TQL 2 TQ Total -pole ase u l -pole 2-pole -pole 2-pole paces at. No. uffix 2 uffix TL240,R U TL270,R U T M U E Identification Type Maximum Number Insert for 3-phase, us mpere Rating Enclosure Type Insert for Insert for pecials of paces 4-wire Load enters owermark old M = Main reaker = 00 = ombination Flush U = opper us or T = Factory Installed L = Main Lug 2 = 25 and urface, Indoor round ar LM = onvertible 5 = 50 F = Flush = ottom Feed Main reaker L = Main Lug, 20 = 200 = urface FL = Factory installed Thermoplastic 22 = 225 R = Outdoor Feed-thru Lugs Enclosure 40 = 40 = Optional door for = 60 circuit indoor panels. (oors 70 = 70 are standard on all other units.) (For details on these and other load centers, see the selection tables on the following pages.) TL42,R TL42, R [ IER QULITY. LOER INTLLE OT. ] owermark old Load enters atalog number is constructed by adding uffix and uffix 2 to ase atalog Number. 2 F = Flush mount indoor = urface mount = ombination flush/surface mount indoor R, R = Outdoor 3 U = opper bus UFL = opper bus, feed-thru lugs UEN = opper bus, generator panel with dual main circuit breakers = Optional door for 6- and 8-circuit indoor panels (door standard on outdoor panels)
4 E L E T I O N T L E. E L E T I O N T L E. E L E T I O N T L E. E L E T I O N T L E. [ ELETION TLE. ] owermark old & lus Load enters UL Listed (anelboards No. 67) 60 /75 onductor Rating Indoor Fronts ombination urface/flush uitable for Use as ervice Entrance Equipment hen Installed in ccordance with the National Electrical ode 22kI RM ymmetrical, Except here Noted Main Lug & onvertible Load enters ingle-phase, Three-wire, 20/240 Volts ac, Top Feed Factory Installed Main Lugs (TLM units convertible to main breaker) owermark lus catalog numbers shown in italics 2 Equipment Maximum paces Indoor Type Enclosure23 Outdoor Type 3R Enclosure3 Main Main ire ize round it mpere TQL Total ox No. ox No. / kcmil Order eparately 2 TQ Rating -pole at. No. ee at. No. ee u-l ee age 6 p 2p p 2p paces age 24 age 25 at. No TL240U4 TL240RU R 4-4 T TL270U4 TL270RU R 6-3 T TL42➄ 2 TL42R➅ R TL TL42T➄8 2 TL42RT➅ R TL Installed TL42R2➅ R -2/0 TL TL42➄7 2 TL42R➅7 R TL TL42T➄ 2 TL42RT➅8 R TL Installed TLM62FU, U0 3, 3 TLM62RU0 R2 T TLM82FU, U90 3, 3 TLM82RU0 R2 T TLM22U 4 TLM22RU R3 TL TLM22U 4 T24 Installed 6-2/ TLM62U 4 T2 or T TLM242U 7 TLM242RU R4 T2 or T TLM205U 8 T32-3/0 (u) 2-3/0 (l) TLM245U 9 TLM245RU R6 T24 or T TLM220RU R5 T TLM620U 8 TLM620RU R5 T TLM620U 8 T32 Installed TLM2020U 9 TLM2020RU R6-250 (u) 2/0-250 (l) T24 or T TLM2020U 9 T42 Installed TLM3220U 2 T TLM4020U 3 TLM4020RU R8 T TLM4222U 4 TLM4222RU R8-300 (u) 2/0-300 (l) T TL2440F, 6 TL2440R R9 (2) TL2 (2) 2/ TL4240F, 2 6 TL4240R 2 R9 (2) TL TL4260F, 2 7 TL4260R 2 R9 (2) (u) (2) (l) (2) TL circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down. For bottom feed door handle, see page amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately (see page 7). 3 TL load center enclosures are thermoplastic; TL and TLM load center enclosures are galvanized steel. 4 No door. ➄ No door, 0kI. 6 0 ki. 7 Maximum branch or main circuit breaker rating: 90 amp with u, 70 amp with l amp maximum branch capacity. 9 FU indicates flush mount enclosure; U indicates surface mount enclosure. dd to catalog number for optional door (example: TLM62U). 0 For main breaker, order TQLR2 retainer kit plus 2-pole circuit breaker. ee page 7. For main breaker, order TQM000. lso order 2-pole TQL, TQL or TQL circuit breaker. ee page 6. 2 Not suitable for use as service entrance equipment.
5 IMENION N NOOUT. IMENION N NOOUT. IMENION N NOOUT. [ IMENION N NOOUT. ] owermark old & lus Load enters Indoor Enclosures imensions (in inches) ox No. idth eight epth nockouts ymbol E F L M N Q R T U V Y Z onduit ize in Inches ox ox2 24 Q Y M Y M Y ox2 ox3, 3 ox4, 6, 7, 8, 9, 0,, 2, 3, 4 F Q Y ox4, 9 Z Z N N ox5 T T ox6 U V R ox7
T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
Catalog Number System For illustrative purposes only. Circuit reaker Selection Guide T H L 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC L = Plug-in
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in
More informationResidential. Section 1.
Load enters Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in ircuit reakers...1-5
More informationLoad Centers and Circuit Breakers
Midwest lectric Products Load enters and ircuit reakers MLM4020U TQL2140 TQL11202 TQL1115 TQL2120T Midwest Load enters pplication Information Midwest load centers lower your costs by making installation
More informationLoad Centers and Circuit Breakers. Section 1.
Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in
More informationSection 1. Load Centers and Circuit Breakers.
Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits... 1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in
More informationLoad Centers and Circuit Breakers. Section 1.
Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in
More informationFull line. Full service. Full value. GE Residential Products
Full line. Full service. Full value. GE Residential Products [ ONTENTS] Full line, full service, full value................................. 1 Q Line circuit breakers........................................
More informationSection 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014
Section Updated 11 / 2014 Q-Line Circuit Breakers Product Features and Benefits...1-2 PowerMark Gold Load Centers Product Features and Benefits...1-3 PowerMark Gold and Plus Load Centers Product Number
More informationMain Wire Size AWG/kcmil. Product Catalog # UPC Code QOM22225NS
QO Load Centers > Catalog umber uide QO 1 8 16 M 100 T FT C CP Position 1 rand QO = QO HOM = Homeline Position 2 Phases Only applies to QO lank or 1 = ingle 3 = Three Position 3 paces Maximum number of
More informationLoad Centers
Siemens would like to welcome the urray Electrical Products into the Speedfax. The urray Electrical Products catalog and Siemens Speedfax has been combined for our customer s convienience. ll of the urray-branded
More informationCircuit Breaker Accessories BREQS125 BRHDK125
anuary 2008 Loadcenters & ircuit reakers Type R Loadcenters & ircuit reakers ircuit reaker ccessories -75 ircuit reaker ccessories TS LW2 RLW2 RQS25 TOW (nstalled) MPL (nstalled) RQLW LW RK25 RML Table
More informationU075CTL A Surface 50/30/20GFCI Twin Lugs
3804 South Street 75964-7263, TX Nacogdoches hone: 936-569-794 Fax: 936-560-4685 llenwatson@elliottelectric.com U075TL00 00 Surface 50/30/20GFI Twin Lugs Midwest Electric roducts atalog Number Manufacturer
More informationQO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers
QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More informationNQOD Circuit Breaker Panelboards
NQOD Circuit reaker Panelboards Class 1630 CONTENTS Description Page pplication Data..................................................... 3 Typical Wiring Diagrams..............................................
More informationSingle Socket and Horizontal Metering
GE Energy onnections Single Socket and Horizontal etering EP pproved Single Socket etering EP pproved pplication Information GE s Single Socket etering products are designed for residential use. They are
More informationEZ Meter-Pak Meter Centers
NEMA 3 onstruction Vac Maximum, for use on A systems, suitable for use as ervice Equipment. tility ompany equirements: eview local utility requirements to ensure that metering equipment meets their standards.
More informationQO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories
QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.
More informationNQOD Circuit Breaker Panelboards
Catalog 2005 Class 1630 CONTENTS Description..............................................Page PPLICTION DT.......................................... 3 TYPICL WIRING DIGRMS.................................
More informationProduct Selection. 2 Circuits 40 and 70 Amperes 4 and 8 Circuits 125 Amperes 2 Circuits 125 Amperes. Outdoor. Box Size. Type of Trim (Included)
January 00 oadcenters & ircuit reakers H oadcenters & ircuit reakers -11 ircuits 0 and 0 s and ircuits 1 s ircuits 1 s Flush (No oor) Flush (No oor) Flush Single-Phase ug oadcenters Table -. Single-Phase
More informationMidwest Electric Products. Temporary Power
Midwest Electric roducts Temporary ower Midwest Electric roducts Temporary ower Midwest Electric provides the temporary power needed by construction trades prior to permanent service equipment installation.
More informationSection 4 Square D QO Loadcentres
Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and
More informationMidwest Electric Products. General Products Catalog
Midwest lectric roducts eneral roducts atalog Midwest lectric roducts eneral roducts atalog Markets ontents Introduction 2 5 ervice quipment 6 29 Disconnects 37 Temporary ower 38 49 ower Outlets 50 63
More informationMidwest Electric Products. AC Disconnects
Midwest Electric Products isconnects Midwest Electric Products pplication Information rticle 440 of the National Electrical ode applies to electric motor-driven air conditioning and refrigerating equipment
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case
More informationQO and HOMELINE Circuit Breaker Load Centers and Enclosures
QO and HOMELIE Circuit Breaker Load Centers and Enclosures Class 1130, 1131, and 1170 COTET chneider Electric Brands Description Page QO Circuit Breaker Load Centers Class 1130............................
More information5.11. Metering Products. Contents Description Systems for Residential and Commercial
3MM, 37MM, 3SS and 37SS Main Tenant ircuit reakers V2/EHD2100 ontents Description Systems for Residential and ommercial pplications............................ Meter Packs.............................
More informationFor the most up-to-date information
www.square.com or the most up-to-date information Thermal-magnetic Molded ase ircuit reakers, 2 mpere rame lass 5,, 734, 8 IL3 JL 3-pole circuit breaker -frame, Thermal-magnetic ( Vac) mpere Magnetic Trip
More informationGE Industrial Solutions. From houses to high-rises GE Residential products and solutions
ndustrial Solutions rom houses to high-rises Residential products and solutions More choices. exclusive options. continues to provide products and solutions for your residential installations that are
More informationSection 8 Stab-lok Circuit Breakers
Section 8 Stab-lok Circuit Breakers Stab-lok easier to work with and faster to install Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique
More information4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering
Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42
More informationDo you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy SM
Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy M Thinking Outside the quare > Who we are chneider Electric total
More informationContents. 4 Loadcentres
POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationLoadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application
Product Offering and Specificaton Guide Application Main lug loadcentre, b Phase 3 W /V, to 0A, / - 0/80 circuits b 3 Phase W /8V, 00 to 5A, - circuits Main Breaker loadcentre, b Phase 3 W /V, to 0A, /
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationFor Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses
mp-trap 2000 Fuses For Type 2, No Damage circuit protection in all the configurations you need. Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive
More informationTHQL1120AF2 THQL1120AF2 Arc Fault BRKR
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15
More informationSection A Busway
Section 8 800 5000 usway usway atalog Numbering System Section 8 800 5000 usway usway atalog Numbering System atalog numbers are composed of two basic parts the prefix (as below), plus the suffix of each
More informationEDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards
-P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit
More informationQwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip. Discount Schedule DE2A
OR URRNT INORMTION I I Two-wire SWN New! 2P I Three-wire SWN QO With Shunt Trip K Key Operated QO and Miniature ircuit reakers QO rc-ault ircuit reaker QO arc-fault circuit breakers provide branch feeder
More informationSingle Socket and Horizontal Metering
G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are
More informationLearning Module 10: Loadcenters. 101 Basic Series
Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case
More informationRetail Reference Guide
www.usa.siemens.com/retail Retail Reference Guide Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI) uses advanced electronic technology
More informationSection 2 HomeLine Loadcentres
Section 2 HomeLine Loadcentres Features that Outclass the Competition The quality you expect from Schneider Electric, the industry leader, is built into all HomeLine loadcentres. One example is our exclusive
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More informationSingle- and Three-Phase Through 600 A. Factory Options SUR = Factory integrated surge. Number of 1-Inch (25.4 mm) Spaces. Maximum Number of Circuits
Loadcenters and Circuit reakers Type R Loadcenters and Circuit reakers.2 Standards and Certifications UL Listings ll aton Type R loadcenters are listed under UL File 52977 except the 2 8 circuit loadcenters,
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More informationQuik-Spec Coordination Panelboard A fusible panelboards
Supersedes July 2018 Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications... 2-3 Enclosure types and voltages/systems.... 4 using, main and feed-through
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationOWNER S MANUAL AND INSTALLATION INSTRUCTIONS
EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR
More informationModular Metering Section 2
Mini Mod III Nomenclature...-3 Photos...-4 Ring -Type and Ringless...-5 Ring -Type and Ringless - MG pproved 5 & 00 Sockets...-6 Tenant Main reakers for Mini Mod Product Family...-7 Factory Installed Lug
More informationCHAPTER V RESIDENTIAL WIRING
CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this
More information1.5 INCH W X 2.91 INCH D X 3 INCH H
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 ax: 936-560-4685 Q0230 QO230 2P-120/240V-30 Square ompany atalog Number Manufacturer escription Weight per unit Product ategory Q0230 Square
More information5.10. Metering Products. Contents. House Panels. Meter Breakers
Metering Products Meter reakers. Contents Description Residential Meter reakers.................. on-euserc Combination Service Entrance Devices 0 00 Styles.................. Meets EUSERC Requirements
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationTHERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS
THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationQuik-Spec Coordination Panelboard A fusible panelboards
USSMNN Supersedes December 2015 SERIES Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications.... 2-3 Enclosure types and voltages/systems.... 4 using, main
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationGE Consumer & Industrial. M-PACT New Air Circuit Breaker A
GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,
More informationOpen, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts
0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationSingle Socket and Horizontal Metering
Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential
More informationSPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents
SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 WireGuide Load Centers and Breakers -4 PL Series Load Centers Features
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationPump Panels Type 3R Enclosure
Type R Enclosure Product Family Overview June 6 Product escription The utler-hammer Pump ontrollers from Eaton s electrical business are combination starters with accessories and modifications designed
More informationNEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems
NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely
More informationRetail Products Catalog
Retail Products Catalog www.schneider-electric.us Table of Contents Overview bout Us...4 Product Definitions Types of Circuit Breakers, Residential Load Centers & other Electrical Devices...6 QO Product
More informationDCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h
D ommercial 3- to 6-Ton Packaged Air onditioner 13 SEE / Up to 11.3 EE ooling apacity: 34,600 71,000 BTU/h ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 7 Airflow Data...
More informationHigh Speed Fuses. Section Contents Page
Section Contents Page General pplications.......................1-13 North merican fuses & accessories...........1-11 DFJ - High speed Class J fuse.................. 15 Square ody fuses & accessories............
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More informationSection 6 Electric Metering: Residential
Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationOVERHEAD SERVICE. Items to consider
OVERHEAD SERVICE Items to consider The maximum length of the service wire from the ComEd pole to the point of attachment on your residence is 150 feet, if practical. Your service wire installation must
More informationDSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient
DS ommercial - 5 Ton Packaged as/ Electric Units 4 SEE / up to 2.0 EE Up to 8% Efficient ooling apacity: 5,000 58,000 BTU/h Heating apacity: 46,000 8,000 BTU/H ontents Nomenclature... 2 Product Specifications...
More informationApplications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim
Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary
More informationFor vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed
Multiple Vertical APPLICATION For vertical multi-meter installations 1-6 meter positions esigned to receive watthour meters that meet ANSI C12.10 Overhead or underground feed CONSTRUCTION Type 3R construction
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS MANUAL TRANSFER SWITCHES FROM 0 Residential Wattage Requirements Appliance Running Watts Add watts for starting Furnace blower, gas or fuel 1/8 hp 300 500 1/8 hp
More informationDCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h
D ommercial - to 6-ton Packaged as/electric Units SEE / up to. EE 80% AFUE ooling apacity: 4,600 7,000 BTU/h Heating apacity: 6,800 0,400 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded
More informationAmp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...
Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. A Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive
More informationSERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company
More information2 THRU 5 TONS SPLIT SYSTEM AHX Series
aicoils AIR HANDLERS 2 THRU 5 TONS SPLIT SYSTEM AHX Series FEATURES o Air C onditioning or Heat P ump ready o P repainted galvanized steel cabinet o Internally lined with R 4.2, 1" Tuf-S kin II insulation
More informationMP Meter-Pak Meter Centers
Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application
More informationTemporary Power Outlet Panels
Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order
More informationPower Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module
Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module
More informationTHERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS
THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.
More information1.3. Loadcenters and Circuit Breakers. Contents Description Standards and Certifications... Product Selection...
OEM Loadcenters Contents s and Certiications................. Product Selection......................... Page V-T-83 V-T-83 Product s a leader in the electrical distribution equipment business, Eaton has
More informationRCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel
RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the
More information!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages
FILE: Distribution Product Catalog!!IERVICEB.aJC Power Outlet Panels CONTENTS Description Class Pages Application Data.......................... 1140........ 36 Dimensions................................
More informationAluminum Mechanical Lugs
luminum Mechanical ugs MNI INUSTRI ONNTORS One- and Two-onductor luminum ugs Suitable for use with either copper or aluminum conductors Manufactured from high strength 6061-T6 aluminum alloy lectroplated
More information