DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h
|
|
- Tracy Owens
- 6 years ago
- Views:
Transcription
1 D ommercial - to 6-ton Packaged as/electric Units SEE / up to. EE 80% AFUE ooling apacity: 4,600 7,000 BTU/h Heating apacity: 6,800 0,400 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded ooling Data... 0 Airflow Data... 8 Dimensions iring Diagrams... 2 Accessories Standard Features -40A chlorine-free refrigerant Patented tubular heat exchanger High-efficiency scroll compressor High and low-pressure switches opper tube / aluminum fin coils ontactor with lugs High-capacity, steel-cased filter drier 24-volt terminal strip onvertible airflow orientation Easy to service Built-in filter rack with standard 2 filters Bottom utility entry omplies with alifornia Low NOx emissions standards AHI ertified; ETL Listed Units meet the performance outlined in Table 6.8.A of ASHAE Standard abinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter ail Sloped drain pan * omplete warranty details available from your local dealer or at SS-D 6/4 Supersedes 4/4
2 Nomenclature D B * * * A * 2 4,5,6 7,8, evision Levels Major & Minor Brand Factory-Installed Options D Daikin X No Options A Non-powered convenience outlet onfiguration B Powered convenience outlet ommercial Low-ambient kit D eturn air smoke detector Application E Supply air smoke detector ooling F Non-powered convenience outlet; as Heat Low-ambient kit H Heat Pump Non-powered convenience outlet; eturn air smoke detector Nominal ross ooling apacity H Non-powered convenience outlet; 06 Tons 02 8½ Tons Supply air smoke detector Tons 20 0 Tons J Non-powered convenience outlet; Tons 50 2½ tons eturn & Supply air smoke detectors Tons 80 5 Tons K Non-powered convenience outlet; 090 7½ Tons Tons Low-ambient kit; Supply air smoke detector L Non-powered convenience outlet; Nominal Heating apacity Low-ambient kit as/electric A/ HP (Factory-Installed Electric Heat) eturn & Supply air smoke detectors ,000 BTU/h XXX No Heat M Powered convenience outlet; ,000 BTU/h 00 0 k 00 0 k Low-ambient kit 5 5,000 BTU/h 05 5 k 0 0 k N Powered convenience outlet; 40 40,000 BTU/h 06 5 k k eturn air smoke detector 20 20,000 BTU/h 08 8 k k O Powered convenience outlet; 50 50,000 BTU/h k k eturn & Supply air smoke detectors ,000 BTU/h k P Powered convenience outlet; See product specifications for heat size(s) available for each capacity. Supply air smoke detector Q Powered convenience outlet; Low- Voltage ambient kit; eturn air smoke detector // //60 Powered convenience outlet; Low // //60 ambient kit; Supply air smoke detector T Powered convenience outlet; Supply Fan/Drive Type/Motor Low-ambient kit; eturn & Supply B Belt Drive air smoke detectors D Direct Drive U Non-powered convenience outlet; Low-ambient kit; eturn air smoke detector Factory-Installed Options V Low-ambient kit; eturn air smoke detector X No Options Low-ambient kit; Supply air smoke detector A Downflow Economizer Y Low-ambient kit; eturn & Supply H Disconnect Switch (non-fused) air smoke detectors J Downflow Economizer; Disconnect Switch (non-fused) Z eturn & Supply air smoke detectors Note: Not all options available for all products. Factory-Installed Options X Standard Aluminized Heat Exchanger S Stainless-Steel Heat Exchanger Factory-Installed Options Stainless-Steel Heat Exchanger (P units only): A tubular heat exchanger made of 409-type stainless steel is installed in the unit. Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the - to 6-ton units, cooling operation is extended from 60 F ambient temperature to 5 F outside air temperature. On 7½- to 20-ton units, cooling operation is extended from 5 F ambient temperature to 0 F outside air temperature. Economizers (Downflow): Based on air conditions, can provide outside air to cool the space. Electric Heat Kits (P and PH units only): Available in all voltage options. Non-powered onvenience Outlet: A 20V, 5A, FI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. Powered onvenience Outlet: A 20V, 5A, FI outlet powered with a transformer built into the unit; for use when unit is not running. hen a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.5A for 208/20V units, increase by.75a for 460V units, and by A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. Disconnect Switch (non-fused): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning (P units) and heat pump models (PH units), the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. eturn Air and/or Supply Air Smoke Detectors: eturn air and/or supply air smoke detectors are installed in the unit. 2 SS-D
3 Product Specifications Tons D06 045D***A* D06 045D***A* D06 045B***A* D B***A* ooling apacity Total BTU/h 4,600 4,600 4,600 4,600 Sensible BTU/h 25,600 25,600 25,600 25,600 SEE / EE /.0 /.0 /.0 /.0 Decibels AHI eference #s Heating apacity High Input / Output kbtu/h 46 / / / / 6.8 Steady State Efficiency (AFUE) Temperature ise ange ( F) No. of Burners Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive # of heels (D x ) (0 x 9 ) (0 x 9 ) ( x 0 ) ( x 0 ) Indoor Nominal FM,200,200,200,200 Motor Speed Tap (ooling) Low Speed Low Speed Indoor Motor FLA (ooling) Horsepower - PM ⅓ ⅓ Piston Size (ooling) Filter Size ( ) () 24 x 24 x 2 () 24 x 24 x 2 () 24 x 24 x 2 () 24 x 24 x 2 Drain Size (NPT) ¾ ¾ ¾ ¾ -40A efrigerant harge ir #(oz.) Evaporator oil Face Area (ft²) ows Deep/ Fins per Inch /6 /6 /6 /6 Belt Drive Evap Fan Data # of heels (D x ) ( x 0 ) ( x 0 ) Motor Sheave / Blower Sheave VL40 X ⅝ / AK69 X VL40 X ⅝ / AK69 X Belt AX52 AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ /,090 ¼ /,090 ¼ /,090 ¼ Fan Diameter/ # Fan Blades 22/4 22/4 22/4 22/4 Outdoor Nominal FM,800,800,800,800 Face Area (ft²) ows Deep/ Fins per Inch / 24 / 24 / 24 / 24 ompressor Quantity / Stage / Single / Single / Single / Single Type Scroll Scroll Scroll Scroll ompressor LA / LA 6.7 / / / / 8.0 Electrical Data Voltage-Phase-Frequency 208/ / / Outdoor Fan HP / FLA ¼ /.4 ¼ /.4 ¼ /.4 ¼ / 0.8 Total Unit Amps Min. ircuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply onduit Hole / Knockout Low-Voltage onduit Hole ½ ½ ½ ½ Operating eight (lbs) Ship eight (lbs) ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. hen a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.5A for 208/20V units, increase by.75a for 460V units, and by A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. SS-D
4 Product Specifications Tons (cont.) D06 090D***A* D06 090D***A* D06 090B***A* D B***A* D B***A* ooling apacity Total BTU/h 4,600 4,600 4,600 4,600 4,600 Sensible BTU/h 25,600 25,600 25,600 25,600 25,900 SEE / EE /.0 /.0 /.0 /.0 /.0 Decibels AHI #s Heating apacity High Input / Output BTU/h 92 / / / / / 74 Low. Input / Output kbtu/h 69 / / / / / 55 Steady State Efficiency (AFUE) Temperature ise ange ( F) Hi / Low / / / / / 0-60 No. of Burners Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive Indoor Nominal FM,200,200,200,200,200 Motor Speed Tap (ooling) Low Speed Low Speed Indoor Motor FLA (ooling) Horsepower - PM ⅓ ⅓ , , ,725 Piston Size (ooling) Filter Size ( ) () 24 x 24 x 2 () 24 x 24 x 2 () 24 x 24 x 2 () 24 x 24 x 2 () 24 x 24 x 2 Drain Size (NPT) ¾ ¾ ¾ ¾ ¾ -40A efrigerant harge ir #(oz.) Evaporator oil Face Area (ft²) ows Deep / Fins per Inch / 6 / 6 / 6 / 6 / 6 Belt Drive Evap Fan Data # of heels (D x ) ( x 0 ) ( x 0 ) ( x 0 ) Motor Sheave / Blower Sheave VL40 X ⅝ / AK69 X VL40 X ⅝ / AK69 X VL40 X ⅝ / AK69 X Belt AX52 AX52 AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ /,090 ¼ /,090 ¼ /,090 ¼ ¼ -,075 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4 Outdoor Nominal FM,800,800,800,800,800 Face Area (ft²) ows Deep/ Fins per Inch / 22 / 22 / 22 / 22 2 / 6 ompressor Quantity / Stage / Single / Single / Single / Single / Single Type Scroll Scroll Scroll Scroll Scroll ompressor LA / LA 6.7 / / / / / 6.5 Electrical Data Voltage-Phase-Frequency 208/ / / Outdoor Fan HP / FLA ¼ /.4 ¼ /.4 ¼ /.4 ¼ / 0.8 ¼ / 0.8 Total Unit Amps Min. ircuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply onduit Hole Low-Voltage onduit Hole ½ ½ ½ ½ ½ Operating eight (lbs) Shipping eight (lbs) ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. hen a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.5A for 208/20V units, increase by.75a for 460V units, and by A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. 4 SS-D
5 Product Specifications 4 Tons D D***A* D D***A* D B***A* D B***A* ooling apacity Total BTU/h 45,500 45,500 45,500 45,500 Sensible BTU/h 5,000 5,000 5,000 5,000 SEE / EE.0 /..0 /..0 /..0 /. Decibels AHI eference #s Heating apacity High Input /Output kbtu/h 92 / / / / 74 Low Input /Output kbtu/h 69 / / / / 55 Steady State Efficiency (AFUE) Temperature ise ange ( F) Hi / Low 0-60 / / / / 5-45 No. of Burners Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Indoor Nominal FM,600,600,600,600 Motor Speed Tap (ooling) Medium Medium Indoor Motor FLA (ooling) Horsepower - PM ½ -,000 ½ -,000.0 /,725.0 /,725 Piston Size (ooling) Filter Size (#) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) Drain Size (NPT) ¾ ¾ ¾ ¾ -40A efrigerant harge (oz.) Evaporator oil Face Area (ft²) ows Deep / Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) () x 0 () x 0 Motor Sheave / Blower Sheave VL44 X ⅝ / AK66 X VL44 X ⅝ / AK66 X Belt AX52 AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,090 ¼ -,090 ¼ -,090 ¼ Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 Outdoor Nominal FM,800,800,800,800 Face Area (ft²) ows Deep / Fins per Inch / 24 / 24 / 24 / 24 ompressor Quantity / Stage / Single / Single / Single / Single Type Scroll Scroll Scroll Scroll ompressor LA / LA 9.9 / 09. / 8.. / / 4 Electrical Data Voltage-Phase-Frequency 208/ / / Outdoor Fan FLA Total Unit Amps Min. ircuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply onduit Hole Low-Voltage onduit Hole ½ ½ ½ ½ Operating eight (lbs) Ship eight (lbs) ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. hen a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.5A for 208/20V units, increase by.75a for 460V units, and by A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. SS-D 5
6 Product Specifications 4 Tons (cont.) D048 5D***A* D048 5D***A* D048 5B***A* D048 54B***A* D048 57B***A* ooling apacity Total BTU/h 45,500 45,500 45,500 45,500 45,500 Sensible BTU/h 5,000 5,000 5,000 5,000 5,000 SEE / EE.0 /..0 /..0 /..0 /..0 /. Decibels AHI eference #s Heating apacity High Input /Output kbtu/h 5 / 92 5 / 92 5 / 92 5 / 92 5 / 92 Low Input /Output kbtu/h / / / / / 69 Steady State Efficiency (AFUE) Temperature ise ange ( F) Hi / Low / / / / / No. of Burners Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive Indoor Nominal FM,600,600,600,600,600 Motor Speed Tap (ooling) Medium Medium Indoor Motor FLA (ooling) Horsepower - PM ½ -,000 ½ -,000.0 /,725.0 /,725 ½ /,725 Piston Size (ooling) Filter Size (#) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) Drain Size (NPT) ¾ ¾ ¾ ¾ ¾ -40A efrigerant harge ir #(oz.) Evaporator oil Face Area (ft²) ows Deep / Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) () x 0 () x 0 () x 0 Motor Sheave / Blower Sheave VL44 X ⅝ / AK66 X VL44 X ⅝ / AK66 X VL44 X ⅝ / AK66 X Belt AX52 AX52 AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,090 ¼ -,090 ¼ -,090 ¼ ¼ -,075 Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4 Outdoor Nominal FM,800,800,800,800,800 Face Area (ft²) ows Deep/ Fins per Inch / 24 / 24 / 24 / 24 / 24 ompressor Quantity / Stage / Single / Single / Single / Single / Single Type Scroll Scroll Scroll Scroll Scroll ompressor LA / LA 9.9 / 09. / 8.. / / / Electrical Data Voltage-Phase-Frequency 208/ / / Outdoor Fan FLA Total Unit Amps Min. ircuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply onduit Hole Low-Voltage onduit Hole ½ ½ ½ ½ ½ Operating eight (lbs) Ship eight (lbs) ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. hen a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.5A for 208/20V units, increase by.75a for 460V units, and by A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. 6 SS-D
7 Product Specifications 5 Tons D D***A* D D***A* D B***A* D B***A* D060 40D***A* ooling apacity Total BTU/h 58,000 58,000 58,000 58,000 58,000 Sensible BTU/h 42,800 42,800 42,800 42,800 4,200 SEE / EE /. /. /. /. /. Decibels AI eference Nos as Heating apacity High Input /Output kbtu/h 92 / / / / 74 8 / 0.4 Low Input /Output kbtu/h 69 / / / / 55 0 / 8 Steady State Efficiency (AFUE) Temperature ise ange ( F) / / / / / No. of Burners Evaporator Motor / oil Motor Type Direct Direct Belt Belt Direct Indoor Nominal FM,900,900,900,900,900 Piston Size (ooling) Filter Size (#) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" -40A efrigerant harge (oz.) Face Area (ft²) ows Deep/ Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 4 / 6 Tube Diameter - Material 5/6 - opper 5/6 - opper 5/6 - opper 5/6 - opper 5/6 - opper Belt Drive Evap Fan Data # of heels (D x ) (" x 0") (" x 0") --- Motor Sheave / Blower Sheave VL44 X ⅝ / AK6 X --- Belt AX5 AX5 --- ondenser Fan / oil Horsepower / PM ¼ /,090 ¼ /,090 ¼ /,090 ¼ /,090 ¼ /,090 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4 Outdoor Nominal FM,800,800,800,800,800 Face Area (ft²) ows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27 2 / 27 Tube Diameter - Material 5MM - opper 5MM - opper 5MM - opper 5MM - opper 5MM - opper ompressor Quantity / Stage / Single / Single / Single / Single / Single Type Scroll Scroll Scroll Scroll Scroll ompressor LA / LA 26.4 / 4 6 / 0 6 / / / 4 Electrical Data Voltage-Phase-Frequency 208/ / / / Outdoor Fan HP / FLA ¼ /.40 ¼ /.40 ¼ /.40 ¼ / 0.8 ¼ /.40 Min. ircuit Ampacity¹ Max. Overcurrent Protection (amps)² Entrance Power Supply Entrance ontrol Voltage ½" ½" ½" ½" ½" Operating eight (lbs) Ship eight (lbs) ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. hen a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.5A for 208/20V units, increase by.75a for 460V units, and by A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. SS-D 7
8 Product Specifications 5 Tons (cont.) D060 40D***A* D060 40B***A* D B***A* D B***A* ooling apacity Total BTU/h 58,000 58,000 58,000 58,000 Sensible BTU/h 42,800 42,800 42,800 42,800 SEE / EE /. /. /. /. Decibels AHI eference #s as Heating apacity High Input /Output kbtu/h 8 / / / / 0.4 Low Input /Output kbtu/h 0 / 8 0 / 8 0 / 8 0 / 8 Steady State Efficiency (AFUE) Temperature ise ange ( F) 5-65 / / / / No. of Burners Evaporator Motor / oil Motor Type Direct Belt Belt Belt Indoor Nominal FM,900,900,900,900 Piston Size (ooling) Filter Size (#) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) 4 x 20 x 2 (4) Drain Size (NPT) ¾" ¾" ¾" ¾" -40A efrigerant harge (oz.) Face Area (ft²) ows Deep/ Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 Tube Diameter - Material 5/6 - opper 5/6 - opper 5/6 - opper 5/6 - opper Belt Drive Evap Fan Data # of heels (D x ) --- (" x 0") (" x 0") (" x 0") Motor Sheave / Blower Sheave --- VL44 X ⅝ / AK6 X VL44 X ⅝ / AK6 X VL44 X ⅝ / AK6 X Belt --- AX5 AX5 AX5 ondenser Fan / oil Horsepower / PM ¼ /,090 ¼ /,090 ¼ /,090 ¼ /,075 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / Outdoor Nominal FM,800,800,800,800 Face Area (ft²) ows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27 Tube Diameter - Material 5MM - opper 5MM - opper 5MM - opper 5MM - opper ompressor Quantity / Stage / Single / Single / Single / Single Type Scroll Scroll Scroll Scroll ompressor LA / LA 6 / 0 6 / / / 8.9 Electrical Data Voltage-Phase-Frequency 208/ / Outdoor Fan HP / FLA ¼ /.40 ¼ /.40 ¼ / 0.8 ¼ / 0.6 Min. ircuit Ampacity¹ Max. Overcurrent Protection ² amps 20 amps 5 amps Power Supply onduit Hole Low-Voltage onduit Hole ½" ½" ½" ½" Operating eight (lbs) Ship eight (lbs) ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. hen a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.5A for 208/20V units, increase by.75a for 460V units, and by A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. 8 SS-D
9 Product Specifications 6 Tons D072 40B***A* D B***A* D B***A* ooling apacity Total BTU/h 7,000 7,000 7,000 Sensible BTU/h 49,800 49,800 49,800 EE / IEE.0 /.2.0 /.2.0 /.2 Decibels AHI Number Heating apacity High Input / Output KBTU/h 8 / / / 0.4 Low Input/ Output KBTU/h 0 / 8 0 / 8 0 / 8 Steady State Efficiency Temperature ise ange ( F) 0-60 / / / 5-45 No. of Burners Evaporator Motor / oil Motor Type Belt Drive Belt Drive Belt Drive # of heels (D x ) (" x 0") (" x 0") (" x 0") Indoor Nominal FM 2,50 2,50 2,50 Indoor Motor FLA (ooling) Horsepower - PM.5-,725.5-,725.5-,725 Piston Size (ooling) Filter Size (Qty) (4) 6" x 20" x 2" (4) 6" x 20" x 2" (4) 6" x 20" x 2" Drain Size (NPT) ¾" ¾" ¾" -40A efrigerant harge (oz.) Evaporator oil Face Area (ft²) ows Deep/ Fins per Inch 4/ 6 4/ 6 4/ 6 Motor Sheave VL44 X 7/8 VL44 X 7/8 VL44 X 7/8 Blower Sheave AK59 X AK59 X AK59 X Belt AX5 AX5 AX5 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ⅓ -,075 ⅓ -,075 ⅓ -,075 Fan Diameter/ # Fan Blades 22/ 4 22/ 4 22/ 4 Outdoor Nominal FM 4,200 4,200 4,200 Face Area (ft²) ows Deep/ Fins per Inch 2/ 27 2/ 27 2/ 27 ompressor Quantity / Stage / Single / Single / Single Type Scroll Scroll Scroll ompressor LA / LA 9/ 2 9.7/ / 50 Electrical Data Voltage/ Phase/ Frequency / / / / / / 60 Outdoor Fan FLA Total Unit Amps Min. ircuit Ampacity¹ 6 2 Max. Overcurrent Protection² 45 amps 25 amps 5 amps Entrance Power Supply.25".25".25" Entrance ontrol Voltage ½" ½" ½" Operating eight (lbs) Ship eight (lbs) ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. hen a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.5A for 208/20V units, increase by.75a for 460V units, and by A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. SS-D 9
10 Expanded ooling Data Tons Outdoor Ambient Temperature Entering Indoor et Bulb Temperature IDB Airflow MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) 0 SS-D
11 Expanded ooling Data Tons (cont.) Outdoor Ambient Temperature Entering Indoor et Bulb Temperature IDB Airflow MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHI ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) SS-D
12 Expanded ooling Data 4 Tons Outdoor Ambient Temperature Entering Indoor et Bulb Temperature IDB Airflow MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) 2 SS-D
13 Expanded ooling Data 4 Tons (cont.) Outdoor Ambient Temperature Entering Indoor et Bulb Temperature IDB Airflow MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P MBh S/T T k Amps HI P LO P IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHI ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) SS-D
14 Expanded ooling Data 5 Tons Outdoor Ambient Temperature Entering Indoor et Bulb Temperature IDB Airflow MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) 4 SS-D
15 Expanded ooling Data 5 Tons (cont.) Outdoor Ambient Temperature Entering Indoor et Bulb Temperature IDB Airflow MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHI ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) SS-D 5
16 Expanded ooling Data 6 Tons Outdoor Ambient Temperature Entering Indoor et Bulb Temperature IDB Airflow MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) 6 SS-D
17 Expanded ooling Data 6 Tons (cont.) Outdoor Ambient Temperature Entering Indoor et Bulb Temperature IDB Airflow MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P MBh S/T T k HI P LO P IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHI ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) SS-D 7
18 Airflow Data Tons Standard Direct Drive Horizontal Standard Direct Drive Down Shot FM Static Amps atts PM Speed Tap FM Static Amps atts PM Low Med High Speed Tap Low Med High Note: Assumes dry coil with filter in place; SFM correction for wet coil = 4% 8 SS-D
19 Airflow Data Tons (cont.) ESP ( H 2 O) Standard Belt Drive Horizontal Turns Open FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP High-Static Belt Drive Horizontal Turns Open ESP ( H 2 O) FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP Standard Belt Drive Down Shot Turns Open ESP ( H 2 O) FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP High-Static Belt Drive Down Shot Turns Open ESP ( H 2 O) FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP Note: Tables represent dry coil without filter; to compensate for filter, add 0.08 to measured E.S.P. SFM correction for wet coil = 4%. SS-D 9
20 Airflow Data 4 Tons Standard Direct Drive Horizontal Standard Direct Drive Down Shot FM Static Amps atts PM Speed Tap FM Static Amps atts PM Low Med High Speed Tap Low Med High Note: Assumes dry coil with filter in place; SFM correction for wet coil = 4% 20 SS-D
21 Airflow Data 4 Tons (cont.) ESP ( H 2 O) Standard Belt Drive Horizontal Turns Open FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP High-Static Belt Drive Horizontal Turns Open ESP ( H 2 O) FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP Standard Belt Drive Down Shot Turns Open ESP ( H 2 O) FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP High-Static Belt Drive Down Shot Turns Open ESP ( H 2 O) FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP Note: Tables represent dry coil without filter; to compensate for filter, add 0.08 to measured E.S.P. SFM correction for wet coil = 4%. SS-D 2
22 Airflow Data 5 Tons Standard Direct-Drive Horizontal Standard Direct-Drive Down Shot FM Static Amps atts PM Speed Tap FM Static Amps atts PM T T T T Speed Tap T T T4 T5 Notes Assumes dry coil with filter in place; SFM correction for wet coil = 4% Five-ton models are shipped from the factory with speed tap set on T SS-D
23 Airflow Data 5 Tons (cont.) ESP ( H 2 O) Standard Belt Drive Horizontal Turns Open FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP High-Static Belt Drive Horizontal Turns Open ESP ( H 2 O) FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP Standard Belt Drive Down Shot Turns Open ESP ( H 2 O) FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP High-Static Belt Drive Down Shot Turns Open ESP ( H 2 O) FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP Note: Tables represent dry coil without filter; to compensate for filter, add 0.08 to measured E.S.P. SFM correction for wet coil = 4%. SS-D 2
24 Airflow Data 6 Tons ESP (In..) Standard Belt Drive Horizontal 0 Turns Turn 2 Turns Turns 4 Turns 5 Turns FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP ESP (In..) Standard Belt Drive Down Shot 0 Turns Turn 2 Turns Turns 4 Turns 5 Turns FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP ESP (In..) High Static Belt Drive Horizontal 0 Turns Turn 2 Turns Turns 4 Turns 5 Turns FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP ESP (In..) High Static Belt Drive Down Shot 0 Turns Turn 2 Turns Turns 4 Turns 5 Turns FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP SS-D
25 Dimensions TOP VIE FLUE/VENT OUTLET OMBUSTION AI INLET (AS UNITS) AS LINE ENTANE FONT VIE ALL DIMENSIONS IVEN AE IN INHES ALL DIMENSIONS AND SPEIFIATIONS AE SUBJET TO HANE ITHOUT NOTIE MODEL TONNAES "A" "B" "" TON OMMEIAL AS, HT MP, AI ONDITIONE TON OMMEIAL AS, HT MP, AI ONDITIONE TON OMMEIAL AS, HT MP, AI ONDITIONE TON OMMEIAL AS, HT MP, AI ONDITIONE ETUN AI DUT SUPPLY AI DUT ONDENSATE DAIN OUTLET LIFTIN SHAKLE HOLES BOTH SIDES AND ENDS FK HOLES BOTH SIDES AND BOTH ENDS D*06-072*** THU 6 TON OMMEIAL IHT END VIE SS-D 25
26 Dimensions (cont.) ONDENSATE DAIN BOTTOM EXIT MOD TON AS, HT M 4 TON AS, HT M 5 TON AS, HT M 6 TON AS, HT M SUPPLY AI DUT ETUN AI DUT BASE PAN VIE (VIEED FOM TOP) ONDENSATE DAIN BOTTOM EXIT MODEL TONNAES "A" "B" "" TON OMMEIAL AS, HT MP, AI ONDITIONE TON OMMEIAL AS, HT MP, AI ONDITIONE TON OMMEIAL AS, HT MP, AI ONDITIONE TON OMMEIAL AS, HT MP, AI ONDITIONE LINE IE ENTANE "A" "" "B" T IE ENTANE LEFT END VIE UN AI DUT SS-D ASE PAN VIE ED FOM TOP)
27 Unit learances Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75 on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48 on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit Beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit s fresh-air intake. Electrical Entrance Locations High-Voltage Entrance (emove Plug) 2⅜ 0¼ Low-Voltage Entrance Low-Voltage Entrance ½ Dia. Power Thru the urb 47½ 7½ SS-D 27
28 oof urb Installation igging Provisions for forks have been included in the unit base frame. No other fork locations are approved. Unit must be lifted by the four lifting holes located at the base frame corners. Lifting cables should be attached to the unit with shackles. The distance between the crane hook and the top of the unit must not be less than 60. Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. emove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. efer to rigging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in oof urb Installation Instructions Manual. efer to the oof urb Installation Instructions for proper curb installation. urbing must be installed in compliance with the National oofing ontractors Association Manual. Lower unit carefully onto roof mounting curb. hile rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. ith condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. hen a rectangular cantilever curb is used, take care to center the unit. heck for proper alignment and orientation of supply and return openings with duct. To assist in determining rigging requirements, unit weights are shown below. orner & enter-of-ravity Locations Unit eights -Ton eights 4-Ton eights 5-Ton eights 6-Ton eights 0 ondenser oil eturn Evaporator oil Supply orner eight (A) orner eight (B) orner eight () orner eight (D) Unit Shipping eight Unit Operating eight Note: eights are calculated without accessories installed. ompressor SS-D
29 oof urb Installation (cont.) urb installations must comply with local codes and should follow the established guidelines of the National oofing ontractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. heck for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. Determine sufficient structural support before locating and mounting the curb and package unit. Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. antilevered-type curbs are not available from the factory. ontractor furnishes curb insulation, cant strips, flashing, and general roofing material. Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings. Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended. See the manual shipped with the roof curb for assembly and installation instructions. -D View Insulated Panels 70¾ 40¼ 4 x 20 Supply Opening ⅝ x 4 eturn Opening ¾ 4 ⅜ Top View SS-D 29
DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient
DS ommercial - 5 Ton Packaged as/ Electric Units 4 SEE / up to 2.0 EE Up to 8% Efficient ooling apacity: 5,000 58,000 BTU/h Heating apacity: 46,000 8,000 BTU/H ontents Nomenclature... 2 Product Specifications...
More informationDCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h
D ommercial 3- to 6-Ton Packaged Air onditioner 13 SEE / Up to 11.3 EE ooling apacity: 34,600 71,000 BTU/h ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 7 Airflow Data...
More informationDCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h
DH ommercial Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches efrigerant accumulator ontactor with lugs
More informationDSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h
DS ommercial 3-5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 35,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... 3 rankercase
More informationDTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE
DT ommercial 5 Tons as/ Electric Units Up to 5.5 SEE and.0 EE Up to 8% AFUE ooling apacity: 5,600 60,000 BTU/h Heating apacity: 6,000 8,000 BTU/h ontents Nomenclature... Product Specifications... Expanded
More informationDSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h
DS ommercial - 5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 5,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... rankercase
More informationDTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h
DT ommercial 3-5 Tons Packaged Air onditioner Up to 15.5 SEER / Up to 13.0 EER ooling apacity: 35,600 60,000 BTU/h ontents Nomenclature...2 Product Specifications...4 Expanded ooling Data...6 Airflow Data...18
More informationCPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h
PH ommercial 7½- to 12½-Ton Self-ontained ooling / Heating apacities: 90,000 118,000 BTU/h Packaged Heat Pump up to 11.5 EE up to 3.5 P Standard Features -410A chlorine-free refrigerant High-efficiency
More informationCPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.
PG ommercial ooling apacity: 90,000 8,000 BTU/h Heating apacity: 68,000 BTU/h Three-Phase 7½- to 2½-Ton Self-ontained Packaged Gas/Electric Units up to.5 EER 80% AFUE Standard Features R-40A chlorine-free
More information3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h
PH ommercial ooling apacity: 5, 7, BU/h Heating apacity: 4,6 7, BU/h - to 6-on Packaged Heat Pump SEE / up to. EE & 7.7 HSPF Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor
More informationDCH Commercial Contents Standard Features Cabinet Features
DH ommercial 7½ - ½ Ton Packaged Heat Pump Up to. EER &. OP ooling apacity: 90,000 0,000 BTU/h Heating apacity: 90,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8
More informationDCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h
D ommercial 7½ - ½ Ton Packaged Air onditioners Up to. EER ooling apacity: 88,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8 Airflow Data... rankcase Heater...0
More informationDX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase. Cooling Capacity: 36,000-60,000 BTU/h
DX13S ommercial Standard Features R-410A chlorine-free refrigerant Energy-efficient compressor Factory-installed filter drier opper tube/ enhanced aluminum fin coil Service valves with sweat connections
More informationDP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h
DP14GM ooling apacity: 23,000 57,500 BTU/h Heating apacity: 40,000 120,000 BTU/h Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons ontents Nomenclature... 2 Accessories... 2 Product Specifications...
More informationDX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase Split System Air Conditioner. Cooling Capacity: 36,000-60,000 BTU/h
DX13S ommercial ooling apacity: 36,000-60,000 BTU/h 3-, 4-, & 5-Ton, Three-Phase Split System Air onditioner ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 AHRI Ratings...
More informationHigh-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger
GPG14M ooling apacity: 23,000 to 57,500 BTU/h Heating apacity: 40,000 to 120,000 BTU/h Packaged Gas / Electric Units 2 to 5 Tons 14 SEER / 81% AFUE ontents Nomenclature... 2 Product Specifications... 3
More informationGPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h
H Packaged Heat Pump ooling apacity: 24,000-57,500 BTU/h Heating apacity: 22,000-54,500 BTU/h 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve PS blower
More informationGPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE
ooling apacities:,000 to 57,500 BTU/h Heating apacities: 40,000 to 10,000 BTU/h GPG14M - to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ontents Nomenclature... Product Specifications... Expanded
More informationDP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h
DP15H ooling apacity: 23,600-57,500 BTU/h Packaged Air onditioner UP TO 15 SEER 2 to 5 Tons ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Airflow Data...16 Heater Kit Data...17
More informationPackaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h
APG4M Packaged Gas/Electric 4 SEER / 8% AFUE ooling apacity:,000 57,500 BTU/h Heating apacity: 40,000 0,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data... 7 Airflow Data...
More informationGSX SEER / 1½ to 5 Tons. Split System Air Conditioner. 18,000-60,000 BTU/h
Split System Air onditioner ooling apacity: 18,000-60,000 BTU/h 13 SEER / 1½ to 5 Tons Standard Features R-410A chlorine-free refrigerant Energy-efficient compressor Factory-installed filter drier opper
More informationGPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h
ooling apacity: 4,000-59,000 BTU/h GP13H - to 5-Ton Packaged Air onditioner 13 SEER / R-410A Standard Features Energy-efficient compressor with internal relief valve PS blower motor; EEM blower motor on
More informationDX11S Commercial & 10-ton, Three-Phase Split System Air Conditioner 11.2 EER / R-410A. Plus
DX11S ommercial 7.5- & 10-ton, Three-Phase Split System Air onditioner 11.2 EER / R-410A Plus 7.5- & 10-Ton, Three-Phase Split System Air onditioner with One Two-Speed Indoor Air Handler and Two 4-Ton
More informationCPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners
CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor
More informationDZ11S Commercial. Plus & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or Two 5-Ton Condensers
DZ11S ommercial 7.5- & 10-Ton, Three-Phase Split System Heat Pump 11 EER / 3.3 OP / R-410A Plus 7.5- & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or
More informationGPH13M. 13 SEER / R-410A 2 to 5 Tons
ooling apacity: 24,000-56,000 BTU/h Heating apacity: 23,000-55,500 BTU/h GPH13M Packaged Heat Pump 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve
More information2- to 5-Ton. Cooling Capacities: 23,600 to 57,000 BTU/h. Packaged Gas/Electric Units. Heating Capacities: 46,000 to 138,000 BTU/h
ooling apacities: 23,600 to 57,000 TU/h Heating apacities: 46,000 to 138,000 TU/h GPG13M 2- to 5-Ton Packaged Gas/Electric Units 13 SEE / 80% AFUE ontents Nomenclature... 2... 3 Expanded ooling Data...
More informationSplit System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner
GS ommercial Split System Air onditioner GS13: 3-5 Tons GS10: 7½ & 10 Tons Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube/aluminum fin coil Brass
More informationDCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.
DG ommercial 7½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% T.E. ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...
More informationDCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.
DG ommercial 7½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% T.E. ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...
More informationGPG13 SINGLE-PHASE, SELF-CONTAINED
P1 SINLE-PHASE, SELF-ONTAINED PODUT SPEIFIATIONS 1 SEE/ 80% AFUE 2 5 TON OOLIN APAITIES: 24,000 TO 56,800 TU/H HEATIN APAITIES: 46,000 TO 18,000 TU/H PAKAED AS/ELETI The P1 Packaged as/electric Unit features
More informationGPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h
Cooling Capacity: 23,000-56,000 BTU/h GPC14M Packaged Air Conditioner 2 through 5 Tons / 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heat
More informationGSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons
ooling apacity: 18,000 to 60,000 Heating apacity: 18,000 to 60,000 High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons ontents Nomenclature... 2 Product Specifications... 3 Expanded
More informationGPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h
GP13M Packaged Air onditioner R-410A, 13 SEER ooling apacity: 36,000-56,000 BTU/h 3, 4, & 5 Tons Standard Features Energy-efficient compressor with internal relief valve EEM blower motor; PS blower motor
More informationDX18TC. High-Efficiency, ComfortNet -Compatible, Split System Air Conditioner Up to 19 SEER. Cooling Capacity: 34,600-58,000 BTU/h
DX18T ooling apacity: 34,600-58,000 BTU/h High-Efficiency, omfortnet -ompatible, Split System Air onditioner Up to 19 SEER ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data...
More informationSSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H
HIGH-EFFIIENY PRODUT SPEIFIATIONS SPLIT SYSTEM AIR ONDITIONER The Goodman Air onditioner uses the environmentally friendly refrigerant R-410A, which is chlorine-free to help prevent damage to the ozone
More informationDP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h
DP13M ooling apacity: 36,000-56,000 BTU/h Packaged Air onditioner 3, 4, & 5 Tons / 13 SEER ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 4 Airflow Data... 10 Heat Kit Electrical
More informationDZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A
DZ11TA ommercial 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/13-13.5 IEER /3.3 OP/R-410A ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Expanded Heating Data...12
More informationDSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h
DSX18 ooling apacity: 34,000-56,000 BTU/h Split System Air onditioner up to 18 SEER Standard Features R-410A chlorine-free refrigerant Two-Stage opeland UltraTech scroll compressor High-density foam compressor
More informationDP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h
DP14HM ommercial ooling apacity: 34,400-58,000 BTU/h Heating apacity: 33,00-57,000 BTU/h 3-5 TON THREE-PHASE PAKAGED HEAT MPS 14 SEER ontents Nomenclature... Product Specifications...3 Expanded ooling
More informationDZ11S Commercial & 10-Ton, Three-Phase
DZ11S ommercial 7.5- & 10-Ton, Three-Phase Split System Heat Pump 11 EER / 3.3 OP / R-410A ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 Expanded Heating Data... 12 AHRI
More informationASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h
ooling apacity: 24,000-60,000 BTU/h High-Efficiency, omfortnet -ompatible, Split-System Air onditioner Up to 19 SEER ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 AHRI
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More informationCPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP
CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP The new Goodman CPH Commercial Packaged Heat Pump features the environmentally friendly refrigerant R-410A, which is chlorine-free to help
More informationAPD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF
APD14 Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 6 Expanded Heating Data... 20 Airflow Data... 22 Dimensions...
More informationCPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h
CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4
More informationGPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h
GPG15 Series Single-Phase, Self-Contained Cooling Capacity: 23,200 56,500 BTU/h Heating Capacity: 69,000 138,000 BTU/h Standard Features High-efficiency compressor Durable, corrosion-resistant T-140 aluminized
More informationDCC Commercial. 15- & 20-Ton, Three-Phase. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h. Packaged Air Conditioners
D ommercial Standard Features R-410A chlorine- free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches High-capacity, steel-cased filter drier
More informationGPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER
Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit
More informationGPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC
GPG COMMERCIAL 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS The Goodman GPG Commercial Packaged Gas/ Electric 10 & 13 SEER units feature energy-efficient cooling and
More informationCPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT
CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT The new Goodman CPG 13 SEER Commercial Packaged Gas/Electric units feature the environmentally friendly refrigerant R-410A, which is chlorinefree
More informationSSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF
High-Efficiency Cooling Capacity: 18,000 to 57,600 BTU/h Heating Capacity: 18,000 to 59,000 BTU/h Split System Heat Pump Up to 15 SEER & 8.5 HSPF Contents Nomenclature... 2 Product Specifications... 3
More informationDZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h
Split-System heat pump Up to 14 SEER / R-410A Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...
More informationGSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER
High-Efficiency, R-410A 1½ to 5 Tons Cooling Capacity: 18,000 to 57,600 BTU/h Split System Heat Pump up to 14 SEER Heating Capacity: 18,000 to 59,000 BTU/h Standard Features R-410A chlorine-free refrigerant
More informationGSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h
Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling
More informationCPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS
11.5 EER / 80% SSE THREE-PHASE COOLING CAPACITY: 118,000 BTU/H HEATING CAPACITY: 210,000 BTU/H CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS The new Goodman CPG Commercial Packaged Gas/
More informationGSC13 Split System Air Conditioner
Split System Air Conditioner 13 SEER / R-22 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 AHRI Ratings... 18 Wiring Diagram... 19 Dimensions... 20 Accessories...
More informationGPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H
GP13M OMMERIAL PAKAGED AIR ONDITIONER PRODUT SPEIFIATIONS The Goodman GP13M ommercial Packaged Air onditioner features energy-efficient cooling and heating performance in one self-contained unit. This
More informationCPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT
CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT The new Goodman CPG 13 SEER Commercial Packaged Gas/Electric units feature the environmentally friendly refrigerant R-410A, which is chlorinefree
More informationGPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H
GPH13H PACKAGED HEAT PUMP 13 SEER 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H The Goodman GPH13H 13 SEER Packaged Heat Pump provides energy-efficient cooling
More informationSSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H
PRODUCT SPECIFICATIONS 14 SEER / R-410A 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER The Goodman Air Conditioner uses the environmentally friendly refrigerant
More informationASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h
Cooling Capacity: 18,000-60,000 BTU/h Split System Heat Pump 13 SEER / R-410A Heating Capacity: 18,000-59,000 BTU/h Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor
More informationTECHNICAL INFORMATION MANUAL
TEHNIAL INFOMATION MANUAL SSZ 16 SEE Split System Heat Pumps Models listed on page 3 efer to Service Manual S6200005 for installation, operation, and troubleshooting information. All safety information
More informationDZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h
Cooling Capacity: 18,000-60,000 Heating Capacity: 18,000-60,000 Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling
More informationDX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h
DX11S Commercial Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube / aluminum fin coil Brass liquid and suction service valves High- and low-pressure
More informationSSZ 16 SEER Split System Heat Pumps
TEHNIAL MANUAL AL SSZ 16 SEE Split System Heat Pumps efer to Service Manual S6200006 for installation, operation, and troubleshooting information. All safety information must be followed as provided in
More informationSSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON
HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP The Goodman uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry.
More informationDSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h
Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Split System Heat Pump Up to 16 SEER & 9.5 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...
More informationDZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A
DZ14S Commercial Cooling Capacity: 34,600 to 56,500 BTU/h Heating Capacity: 32,800 to 59,000 BTU/h 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A Contents Nomenclature...2 Product Specifications...3
More informationDCG Commercial. 15- & 20-Ton, Three-Phase
DG ommercial 5- & 0-Ton, Three-Phase Packaged Gas/Electric Standard eatures -0A chlorine-free refrigerant Patented tubular heat exchanger High-efficiency scroll compressor opper tube / aluminum fin coils
More informationTECHNICAL MANUAL. *SZC 18 SEER Split System Heat Pumps
TEHNIAL MANUAL AL *SZ 18 SEE Split System Heat Pumps efer to Service Manual S6200006 for installation, operation, and troubleshooting information. All safety information must be followed as provided in
More informationSSZ 14 SEER Split System Heat Pumps
TEHNIAL MANUAL AL SSZ 14 SEER Split System Heat Pumps Refer to Service Manual RS6200005 for installation, operation, and troubleshooting information. All safety information must be followed as provided
More informationDCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE
Submittal Data Form Job Name DCG Series 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Cooling Capacity: 88,000 144,000 BTU/h Heating Capacity (Output): 168,000 BTU/h Purchaser Order No.
More informationTECHNICAL MANUAL. *SZC 16 SEER Split System Heat Pumps
TEHNIAL MANUAL AL *SZ 16 SEER Split System Heat Pumps Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. All safety information must be followed as provided
More informationGSZ/VSZ 13 SEER Split System Heat Pumps
TEHNIAL MANUAL AL GSZ/VSZ 13 SEER Split System Heat Pumps Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. All safety information must be followed as provided
More informationDCG Commercial. 7½- to 10-Ton Three-Phase Packaged Gas/ Electric. Cooling Capacity: 88, ,000 BTU/h Heating Capacity (Output): 144,000 BTU/h
DG ommercial ooling apacity: 88,000 116,000 BTU/h Heating apacity (Output): 144,000 BTU/h 7½- to 10-Ton Three-Phase Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE ontents Nomenclature... 2 Product Specifications...
More informationAVXC20. High-Efficiency, Comfortnet-Compatible, Variable-Speed, Inverter Drive Split System Air Conditioner. Cooling Capacity : 23,600 53,000 BTU/h
AVXC20 Cooling Capacity : 23,600 53,000 High-Efficiency, Comfortnet-Compatible, Variable-Speed, Inverter Drive Split System Air Conditioner Contents Nomenclature... 2 Product Specifications... 3 Expanded
More informationARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit
More informationPGC COMMERCIAL PACKAGED GAS/ELECTRIC
PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric
More informationASPF. Product Specifications. Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor
Multi-Position Air Handler with Energy-Saving Motor The Goodman brand Multi-Position Air Handler is suitable for use with refrigerants -0A and -. This unit s blower design includes an E fixed-speed motor
More informationPACKAGE GAS ELECTRIC UNITS
PACKAGE GAS ELECTIC UNITS FOM NO. TZ-870 EV. 1 TZGE4 14 SEE SEIES NOMINAL SIZES 2-5 TONS [7.0-17.6 kw] TZGE5 15 SEE SEIES NOMINAL SIZES 2-5 TONS [7.0-17.6 kw] NL 1 PL 14.0 L 16.0 ATED IN ACCODANCE (15
More informationDCC Commercial Tons Packaged Air Conditioners
DCC Commercial - Tons Packaged Air Conditioners Tons Cooling Capacity: 80,000 BTU/h 0 Tons Cooling Capacity: 0,000 BTU/h Tons Cooling Capacity: 90,000 BTU/h Contents Nomenclature... Product Specifications...
More informationDTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER
DTC Series Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features
More informationQ6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged
More informationGQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY
TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can
More informationQ6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged
More informationTECHNICAL GUIDE R-410A AFFINITY SERIES DNZ MODELS 2-5 TON 60 Hertz
78-YTG--07 TEHNIAL GUIDE -0A AFFINITY SEIES MODELS - 5 TON 60 Hertz Description These York Affinity packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct
More informationARBOR COMPACT SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZ 08/18
ABO OMPAT SEIES OMMEIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD1201AZ 08/18 Model Nomenclature 1 2 3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21-22 23 Z B V 036 T L 0 0 0 A N A
More informationAVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...
More informationQ6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY
TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can
More information14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON
14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech
More informationTECHNICAL MANUAL. *PC 14 SEER R-410A Package Air Conditioners with R-410A
TEHNIAL MANUAL AL *P 14 SEER R-410A Package Air onditioners with R-410A Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. All safety information
More informationQ6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units
TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationARBOR BASE SERIES COMMERCIAL Geothermal/Water Source Heat Pumps Tons. Submittal Data English Language IP/Metric Units SD1201AZB 03/16
ABO BASE SEIES OMMEIAL 0.5-6 Tons Submittal Data English Language IP/Metric Units SD1201AZB 03/16 Model Nomenclature 1 2 2 3-5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20-21 22 Z B V 036 T L 0 0 0 A N A N
More informationP6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can
More informationPCB COMMERCIAL SERIES
PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH2SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE