New York City Apartment Metering Meter Sockets / Load Centers
|
|
- Hilda Shaw
- 6 years ago
- Views:
Transcription
1 s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001
2 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase, 4 Wire or 120/240V AC, 1 Phase, 3 Wire Maximum line terminal - (2) 500 kcmil/phase Output: 120/208Y, 1 Phase, 3 Wire or 120/240V AC, 1 Phase, 3 Wire, 100 amps continuous/meter position (125 amps maximum) Meter Sockets: 5 jaw, with 5th jaw located at 9 o clock and electrically connected to neutral bus Tenant Circuit Breakers: Use Siemens Type QP 2-pole plug-on circuit breakers, (100 amps maximum) Product Descriptions Siemens New York City Apartment Metering is a versatile, unassembled modular metering product comprised of separate modules that may be assembled to produce a variety of configurations. Only those standard modules shown in this publication will be sold. Installation instructions are shipped with the product. The modules are: Meter Stacks Meter stacks are available from 2 to 5 meter positions, arranged vertically and pre-bussed on the line side. Each meter position is rated 100 amps continuous (125 amps maximum), 5 jaw, with the 5th jaw located at 9 o clock and connected to the stack neutral bus. For indoor mounting only. Line Troughs Line troughs are indoor horizontal wireways that support the meter stacks and supply unmetered line power to meter stack bus. Line trough is available from 2-5 stack positions and may be ganged by means of couplers to accommodate 6 or more stacks. Phase blocks and line terminals are required to terminate line conductors and to provide means to field wire each stack. Trough end walls are ordered separately. Phase Blocks Phase blocks are required to terminate line conductors and provide terminals for field connection to each stack bus. Phase blocks are available with 3, 6 or 12 take-off lugs. 2
3 Line Terminal Kits Line terminals are available in kits of 4 terminals each. The terminals are tang lugs which mount on threaded studs provided on the phase blocks. Terminals are available in 3 sizes: (1) 350 kcmil (1) 500 kcmil (2) 500 kcmil maximum End Wall Kits These kits each contain 4 end walls; 2 end walls for the line trough and 2 end walls for the breaker trough. Coupler Kits These kits each contain 2 trough coupler straps; one for the line trough and one for the breaker trough. These couplers mount using the same mounting screw holes as the end walls. Breaker Troughs Breaker troughs are horizontal indoor wireways that contain provisions for plug-in circuit breakers used as tenant mains. The troughs bolt to the top of the meter stacks. Field wiring connects each meter socket to a circuit breaker mounting block. Breaker troughs are available in 2 to 5 stack positions and can be ganged to accommodate 6 or more stacks. Trough end walls are ordered separately. Circuit Breakers New York City Apartment Metering uses standard 2-pole plug-on circuit breakers, Siemens Type QP, 100 amps maximum. Getting Started Line Trough Spacer Kits These kits may be used to increase wire bend space between the first phase block and line entrance end wall, if necessary. They connect to line troughs with a standard coupling kit. Trough end walls are ordered separately. Before ordering components, the following should be known: installation instructions are shipped with the product. number of meter positions amp rating of each meter position voltage and phase of incoming line line conductor size and quantity per phase vertical and horizontal space limitations, if any Meter stacks are 10 wide and are 10 high for each meter position, or blank position. (A 3-high stack with no blank positions would be 10 wide and 30 high). When considering the overall height of an installation, you must add the height of the line trough (12 ) and the breaker trough (16 ) to the stack height. An installation of 3-high stacks would be 58 in overall height ( = 58 ). All meter stacks in the same meter bank must be the same height to allow the breaker trough to fit on top of the stacks. 3
4 Selection and Specifications Meter Stacks Selection Chart #1 Meter Bank Height and Width Meter Stack Combinations for Various Heights and Widths, by Number of Meter Positions No. of 58 High 68 High 78 High Meter Use this Quantity of: Width Use this Quantity of Width Use this Quantity of: Width Positions SUVS310 SUVS311B (Inches) SUVS410 SUVS411B (Inches) SUVS510 SUVS511B (Inches) Not Practical Not Possible Not Practical Not Practical Use (3) SUVS310 instead of (3) SUVS411B. Use 3-high or 4-high stacks. Specification Chart #1 Meter Stacks 300V AC max., 100 Amps/Position Continuous Duty, 1 or 3 Phase Network Meter Height Catalog Wire Range Positions (Inches) Number Quantity Approx. Wt. (lbs.) Line Terminals 2 20 SUVS #6-4/ SUVS311B 1 21 #6-4/ SUVS #6-4/ SUVS411B 1 29 #6-4/ SUVS #6-4/ SUVS511B 1 37 #6-4/ SUVS #6-4/0 All stacks are 10 wide. Meter Stacks (Use Selection Chart #1 and Specification Chart #1) Knowing the number of meter positions, and the height and width requirements, select quantity and catalog number of stacks from Selection Chart #1. The height dimension in this chart includes line and breaker troughs. For specs, refer to Specification Chart #1. 4
5 Selection and Specifications Line Troughs / Breaker Troughs / Phase Blocks Line Troughs Specification Chart #2). Knowing the number of meter stacks (not meter positions!) from above, select the quantity and catalog numbers of line troughs from Selection Chart #2. For specs, refer to Specification Chart #2. Breaker Troughs Specification Chart #3) Using the total number of meter stacks (not meter positions!), select the quantity and catalog numbers of breaker troughs from Selection Chart #2 and spec from Specification Chart #3. Use QP style breakers only. Breakers not included. Phase Blocks Specification Chart #4). Using the number of meter stacks and the incoming power supply, use Selection Chart #2 to determine the quantity and catalog number of phase blocks for line and neutral termination. Spec these from Specification Chart #4. Selection Chart #2 Line Trough, Breaker Trough and Phase Block Selection Phase Block Selection No. of Meter Line Trough Selection Breaker Trough Selection 3 Phase, 4 Wire System 1 Phase, 3 Wire System Stacks Left Middle Right Left Middle Right Line Neutral Line Neutral in Bank Trough Trough Trough Trough Trough Trough Blocks Block Blocks Block 3 SULT30 SUBT30 (3) SUPB3 (1) SUPB3 (2) SUPB3 (1) SUPB3 4 SULT40 SUBT40 (3) SUPB3 (1) SUPB6 (2) SUPB6 (1) SUPB6 5 SULT50 SUBT50 (3) SUPB6 (1) SUPB6 (2) SUPB6 (1) SUPB6 6 SULT30 SULT30 SUBT30 SUBT30 (3) SUPB6 (1) SUPB6 (2) SUPB6 (1) SUPB6 7 SULT40 SULT30 SUBT40 SUBT30 (3) SUPB6 (1) SUPB12 (2) SUPB12 (1) SUPB12 8 SULT40 SULT40 SUBT40 SUBT40 (3) SUPB6 (1) SUPB12 (2) SUPB12 (1) SUPB12 9 SULT50 SULT40 SUBT50 SUBT40 (3) SUPB6 (1) SUPB12 (2) SUPB12 (1) SUPB12 10 SULT50 SULT50 SUBT50 SUBT50 (3) SUPB12 (1) SUPB12 (2) SUPB12 (1) SUPB12 11 SULT40 SULT40 SULT30 SUBT40 SUBT40 SUBT30 (3) SUPB12 (1) SUPB12 (2) SUPB12 (1) SUPB12 12 SULT40 SULT40 SULT40 SUBT40 SUBT40 SUBT40 (3) SUPB12 (1) SUPB12 (2) SUPB12 (1) SUPB12 Spacer SULT10SP is required if line conductors exceed #6 Awg. Spacer SULT10SP is required if line conductors exceed #350 kcmil. Requires (1) SUCP1216 Coupler Kit. Kit provides coupling straps for both line and breaker troughs. Requires (2) SUCP1216 Coupler Kits. Kit provides coupling straps for both line and breaker troughs. Specification Chart #2 Line Troughs 240V AC max., 1 Phase or 3 Phase Stack Width Catalog Approximate Positions (Inches) Number Quantity Weight (lbs.) 2 20 SULT SULT SULT SULT Line troughs are 12 high. Will not accommodate Phase Blocks. Specification Chart #3 Breaker Troughs Stack Width Catalog Approximate Positions (Inches) Number Quantity Weight (lbs.) 2 20 SUBT SUBT SUBT SUBT Use Siemens Type QP circuit breakers. Breakers not included. Height is 16. Specification Chart #4 Phase Blocks 240V AC max., 1 Phase or 3 Phase Number of Catalog Wire Range Take-off Lugs Number Quantity Approximate Wt. (lbs.) Line Load 3 SUPB /8 x 16 Stud #6 - #4/0 6 SUPB /8 x 16 Stud #6 - #4/0 12 SUPB /8 x 16 Stud #6 - #4/0 Requires separate line lug kit. 5
6 Selection and Specifications Line Terminals / End Walls and Coupling Kits / Accessories Line Terminals (Use Specification Chart #5). Knowing the size and quantity per phase of the line conductors, select and spec these from Specification Chart #5. Line terminals come in kits of 4 terminals each. One kit will supply line terminals for 3 phase legs and neutral. End Walls (Use Specification Chart #6) NOTE: Each installation MUST have an end wall kit! The kit provides end walls for each end of the line and breaker troughs. (4 end walls). Use Specification Chart #6. Coupling Kits Specification Chart #6) When more than one line trough is needed to support the number of meter stacks on a job, or when a line trough spacer is required, coupling straps are required to connect the troughs. Use Selection Chart #2 footnotes 3 and 4 to determine quantity of coupling kits required. Each kit provides one strap for line trough and one strap for breaker trough. Spec from Specification Chart #6. Line Trough Spacer Kits Specification Chart #6) In some applications, the first phase block may be too close to the end wall of the line trough to provide proper wire bend space for the line conductors being used. Selection Chart #2 footnotes 1 and 2 will show when spacer kits are required. Tenant Circuit Breakers Each meter position in use requires a tenant circuit breaker. Use standard Siemens Type QP circuit breakers from the Speedfax Catalog. Specification Chart #5 Line Terminals Catalog Approximate Wire Range Number Quantity Weight (lbs.) (1) #6-350 kcmil SULK (1) #4-500 kcmil or (2) #1/0-250 kcmil SULK (2) #2-500 kcmil SULK Quantity 1 Package = 4 Lugs. Specification Chart #6 End Wall and Coupling Kits Catalog Approximate Item Number Quantity Weight (lbs.) End Wall Kit Contains 4 end walls; 2 for line trough and 2 for breaker trough SUEW Coupling Kit Contains 2 coupling straps; 1 for line trough and 1 for breaker trough SUCP Specification Chart #7 Accessories 6 Catalog Approximate Item Number Quantity Weight (lbs.) Spacer 10 spacer for use with line trough to provide wire bend space where required SULT10SP Meter Cover SUMCVR Blank Position Cover SUMBCVR Plastic Meter Cover (Ring Type) WSX087M Breaker Filler Plate QF
7 Meter Sockets / Load Centers Product Descriptions Meter Sockets: Design / Performance Features Steel enclosures are fabricated from 16, 14 or 12 gauge, commercial grade G90, zinc coated steel which is mill phosphatized to assure finish adhesion. Enclosure finish is a 2-3 mil organic polyester resin base. Finish is applied inside and outside to clean, and dry metal as an electrostatic charged powder to grounded assemblies. The finished assembly is then oven cured. Enclosure covers (except for ring style sockets) are supplied with a 300 series stainless steel rotary latch with a slot for ribbon or wire seals and a 3/8 diameter hole for a padlock. Ring style sockets have an internal slide latch. Meter socket jaws are fabricated from high conductivity, tin plated, copper alloy. Insulating jaw support blocks are fabricated from a high impact, non-tracking thermoset polyester. Meter socket connectors are fabricated from extruded high conductivity aluminum for lay-in style with either steel (100 ampere) or extruded aluminum (150 and 200 ampere) lug tops. Choice of top endwall options hub openings, closure plates, blank endwalls, hub installed. Complete selection of accessories including hubs, fifth jaws, and meter opening covers. Safety guide reduces chance of accidental contact with energized line jaws during installation or removal of meter or cover. Aligns meter in socket. Performance Engineered Meter Sockets Siemens offers a complete line of single and multiple meter sockets encompassing ring and ringless types in both normal duty and heavy duty construction. Sockets are available to satisfy the mounting requirements for both self-contained and transformer rated meters. Meter Sockets A meter socket is an enclosed device which has jaws to accommodate the matching blade terminals of an S base watthour meter and has connections for terminating the circuit conductors. Siemens offers single-position sockets for one meter or multiple-position sockets for two or more meters. Multipleposition sockets may be fabricated as one complete unit with two or more socket positions, or fabricated as one or more separate socket positions with removable sidewalls, and coupling straps for ganging into a multiple position socket assembly. Ring Type Meter Sockets A ring type meter socket has a socket curl for use with a sealing ring which holds the watthour meter in place. The socket curl is an integral part of the meter socket cover. The cover may be a latch type, secured in place by a latch; or a cross bar type, secured through the cross bar. Ringless Type Meter Sockets A ringless type meter socket has no provision for a socket sealing ring but uses the cover to hold watthour meter in place. The cover is sealable by the utility. Meter Bypass A meter bypass permits changing or testing a meter without interrupting the service. Siemens offers two types of bypasses. Manual bypasses for ringless type meter sockets are factory installed. The lever type is used on 200 ampere devices (200 and 320 Amp Heavy Duty Ringless Socket have Jaw Release - Lever Bypass) and the horn type is used on 125 and 200 ampere devices. Load Centers: Siemens main lug 3-phase load centers are designed specifically for New York City. These panels comply with the New York City Electrical Code (Title B, Article 13, Chapter 30) bulletin 124 and are approved by the Bureau of Electrical Controls Advisory Board. These load centers are designed for use with Siemens circuit breakers. These panels are equipped with wide gutters to allow for wire bending and easier installation. Some features and benefits of the New York City Load Centers are: 3-phase main lug only Wide gutters - load centers over 100 amps; meets New York City Electrical Code; easier installation Dielectric testing - load centers over 100 amps are tested to meet New York City Electrical Code requirements. UL Listed - Eliminates inspection problems 7
8 Selection and Specifications Meter Sockets / Load Centers Con Ed and New York City Approved UL Listed Ring Type No Bypass Amps Std. Package Wire Accessories Cont. Volts Catalog Approx. Dimensions (Inches) Range Access Max. Duty A.C. Number Qty. Wt. Lbs. Length Width Depth Cu/Al Hub 5th Jaw WSN152C /2 #8-2/0 UG-None Installed WSN152CC /2 #8-2/0 1-1/4 Interch. Installed WSN152CX /2 #8-2/0 WRX Provision Installed WSS152C /8 #2-350 kcmil UG-None Installed WSS152CX /8 #2-350 kcmil WRX Provision Installed Sealing ring not included. Dimensions shown are representative of outside box length, width & depth (+/-1/8 ) and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Consult factory for specific details if required. 6th Jaw available, order WRX112FJ 3 o clock only. 5th Jaw at 9 o clock only. Ring Type, Unbussed, End Fed, Indoor, Insulated Groundable Neutral Amps Wire Accessories No. Dimensions (Inches) of Cont. Catalog Std. Approx. Range Coupling Pos. Max. Duty Number Pkg. Wt. Lbs. Length Width Depth Cu/Al 5th Jaw Strap Line #6-4/ WSC150C /4 15-1/4 3-7/8 Load #8-2/0 Installed WSX008M Line #6-4/ WSC250C /4 30-1/2 3-7/8 Load #8-2/0 Installed WSX008M Line #6-4/ WSC350C /4 45-5/8 3-7/8 Load #8-2/0 Installed WSX008M Gang 2 of above with coupling strap Line #6-4/ WSX008M and price accordingly. Load #8-2/0 WSX019 WSX008M Dimensions shown are representative of outside box length, width & depth (+/-1/8 ) and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Consult factory for specific details if required. 5th Jaw at 9 o clock only. Ring Type, Bussed, End Fed, Outdoor, Bonded Neutral with 5th Jaw Amps No. Dimensions (Inches) Wire Range of Cont. Catalog Std. Approx. Pos. Duty Number Pkg. Wt. Lbs. Hub Length Width Depth Cu/Al Line #6-250 kcmil WSN251CR WRX 13-3/4 17-1/4 4-3/4 Load #8-2/0 Line #6-250 kcmil WSN351CR WRX 13-3/4 25-3/4 4-3/4 Load #8-2/0 Line #6-250 kcmil WSN451CR WRX 13-3/4 34-1/2 4-3/4 Load #8-2/0 Line #6-250 kcmil WSN551CR WRX 13-3/4 43-1/8 4-3/4 Load #8-2/0 3 Phase, 4 Wire 120/240V AC or 208Y/120V AC or 3 Phase, 4 Wire 240V AC Main Lug Only Dimensions (Inches) Catalog Number Amps 1 Spaces Max. CRT Length Width Depth Wire Range G1224ML310SCY /8 13-1/8 3-7/8 #4-2/0 G2430ML310SCY /8 13-1/8 3-7/8 #4-2/0 G2442ML315SCY /8 17-5/8 4 #4-3/0 G3042ML32SCNY /8 17-5/8 4 #4-250MCM G4242ML32SCNY /8 17-5/8 4 #4-250MCM Siemens Energy & Automation, Inc. Distribution Products Division Residential Products 5400 Triangle Parkway Norcross, GA Siemens Energy & Automation, Inc. Siemens is a registered trademark of Siemens AG Bulletin RPSA-S0001(New) 5M0697SP Printed in U.S.A.
MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationPower Mod. Introduction.
Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination
More informationSection 6 Electric Metering: Residential
Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.
More informationMP Meter-Pak Meter Centers
Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More informationfastfax Rock Solid TM Load Centers General Information
General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationMeter Centers Meter Mounting Devices
Meter Mounting Devices General General Information Materials: 16 gauge, galvanized steel, G-90 Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION
More informationEquipment. Metering. Metering Equipment 1. Contents
1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................
More informationMEG Approval Meter Equipment Group
MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationMetering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering
Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal
More informationNew England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that
More informationPower Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module
Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module
More informationEquipment. Metering. Metering Equipment 1. Contents
1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................
More informationStandard switch modules (type WS) are designed for flexibility, space savings, & durability.
Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800
More informationWisconsin Area Catalog
Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationModular Metering Application Guide
GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III
More informationCON EDISON EQUIPMENT
CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More informationModular Metering Construction Details
GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single
More informationCABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers
More information10. METERING General Requirements
10. METERING 10.1 General Requirements A. The Company will not supply service to a Customer whose wiring is designed for resale of electricity through submetering except for recreational campgrounds, marinas,
More informationMeter Mounting Equipment Wisconsin Area
Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationCurrent Transformer, Termination & Disconnect Cabinets WE Energies Approved
Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...
More informationMeter Mounting Equipment DTE Energy Area
Meter Mounting Equipment DTE Energy Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationMETERING REQUIREMENTS
METERING REQUIREMENTS KUA will not accept a non-securable service trough entrance. That is, all enclosed conductors prior to the meter (line side) will be securable by and accessible to KUA personnel only.
More informationDesign Standard. Purpose: Design Standard:
Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard
More informationPower Mod. Standard Tapboxes.
Power Mod Standard tapbox modules (type WTB) are designed for versatility, space savings, and flexibility. Features include: J QuickSystem features J Standard compression lug capability J Invertibility:
More informationGroup Meter Main - Without Bypass
100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationMeter Mounting Equipment. Northern Indiana Public Service Co.
Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationSECTION 500 METERING AND ASSOCIATED EQUIPMENT
SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.
More informationSAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)
.&. SAFETY SOCKET BOX USE: 1 12/24V 1A & 2A 4 Terminal EUSERC Dwg. No's 34 & 35 (With Factory Installed Test-Bypass Facilities) Refer to SR-452 for the complete Front View Lower-Panel Removed Note 3 3"
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationCT Metering. CT Metering. Meter Mounting Equipment
Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination
More informationDuke/MEG Approval Meter Equipment Group
Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides
More informationMultiple Metering, Vertical Gang
Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or
More informationSelection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting
Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -
More informationMultiple Metering, Horizontal Gang - Non Lever Bypass
Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground
More informationSelection and Application Guide For use in New England EQUIPMENT
Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,
More informationREC Municipal Meter Mounting Equipment
REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationSPEEDFAX TM 2011 Meter Centers Contents
SPEEDFAX TM 011 Meter Centers Contents Single and Multiple s - -19 General Information - -3 Single Position s - Residential Types -4-5 Multiple Position s Residential Types -6-7 Single Position s Commercial
More informationPOWER PRODUCT Meter Centres Contents
POWER PRODUCT Meter Centres Contents General Specifications - Catalogue Numbering System - 40V Meter Centre Overview - Features & Benefits -3 Procedure -5 Switches and Tap Boxes -6 Meter Stacks -7 Socket
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationLouisiana/Mississippi. Area Catalog
Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationMeter Mounting Equipment. GA/AL/FL Panhandle Area
Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke
More information5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection
.11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box
More informationService Entrance Methods
Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationMetering NEED. Meter Sockets. Product Description
Meter Sockets Meter Sockets Single Position (Ring, Ringless and Bypass)........ - Multiple Position Without Tenant Main Breakers.......... - Accessories.......................... -7 Meter Packs (All-in-Ones)
More informationClark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.
This page left blank intentionally. 38 Chapter 4: Commercial Metering / January 2011 APPENDIX Glossary Approval Acceptable to the authority having jurisdiction. Associated equipment As related to metering
More informationOhio Meter Mounting Equipment
Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures
More information4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering
Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant
More informationModular Metering Application Guide. Meter Mod * III Product Family
Modular Metering Application Guide Meter Mod * III Product Family Table of Contents Page No. Selection Guidelines and Nomenclature 3 UL Standard Listing and File Numbers for Meter Mod III Product Family
More information4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...
.5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,
More informationSelection & Application Guide. BFT Main Feed Thru Modules. Power Mod. usa.siemens.com/powermod
Selection & Application Guide BFT Main Feed Thru Modules Power Mod usa.siemens.com/powermod Power Mod BFT - Main Feed Thru Modules Selection and Application Guide Power Mod BFT - Main Feed Thru Modules
More informationSingle Socket and Horizontal Metering
Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential
More informationIndiana Meter Mounting Equipment
Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationContents. 4 Loadcentres
POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ
More informationSECTION VII METERING INSTALLATIONS
SECTION VII METERING INSTALLATIONS 1. GENERAL Outdoor metering is required for all new service installations to one, two, and three family detached, semi-detached and row houses. 2. COMPANY FURNISHES AND
More informationSelection and application guide
Selection and application guide For use in Louisiana and Mississippi Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationSingle Socket and Horizontal Metering
G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are
More informationMeter Mounting Equipment Florida Area Catalog
Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert
More informationNew Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment
New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work
More informationCP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationTERMINATION ENCLOSURE OPTIONS
TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At
More information5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.11 Metering Products Systems for Residential and Commercial Application Systems for Residential and Commercial Applications Product Description Group metering is a service entrance product line that consists
More informationComEd Service Area Meter Mounting Equipment
ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs
More informationSpecialty Service Entrance Switchboards. Selection and Application Guide
Specialty Service Entrance Switchboards Selection and Application Guide Power! As the heart of every business complex it has to be reliable. As part of your business, it has to be economical too.you get
More informationInstrument Rated Metering Equipment
Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions
More informationtot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,
' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *
More informationEZ Meter-Pak Meter Centers
NEMA 3 onstruction Vac Maximum, for use on A systems, suitable for use as ervice Equipment. tility ompany equirements: eview local utility requirements to ensure that metering equipment meets their standards.
More informationSelection and application guide. For use in Ohio. Meter Mounting Equipment.
Selection and application guide For use in Ohio Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and general
More informationHeavy Duty Safety Switches
eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationMARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters
MARWELL CORPORATION WWW.MARWELLCORP.COM PO BOX 139 MENTONE CA 92359 (909) 79-192 FAX (909) 79-0250 Red Section Single Phase A-Base to S-Base Adapters, 100 ABase Conversion Adapter, 2000 Series, 2500 Series,
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase
More informationIntroduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3
Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change
More informationWall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12
763.422.2600 SPEC-00245 L763.422.2211 DISCONNECT WALL-MOUNT PREFERRED-CUTOUT DISCONNECTS PREFERRED CUTOUT, DISCONNECTS, TYPE 12 Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type
More informationUNDERGROUND SERVICES - SECONDARY
UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service
More informationSTOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION
CHAPTER 1 - GENERAL INFORMATION 100. Purpose 101. Codes and rules 102. Continuity of service 103. Frequency, Voltage, and Amperage Limitations 104. High voltages 105. Unusual capacity requirements 106.
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More informationPower Mod. Type WMM Residential Meter Stacks. Revised 06/01/13. Residential Meter Stacks
Type WMM Residential Meter Stacks 06/01/13 Residential Meter Stacks Power Mod s core offering of Residential Meter Stacks, type WMM, offers the widest product offering and flexibility in the industry.
More informationFor vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed
Multiple Vertical APPLICATION For vertical multi-meter installations 1-6 meter positions esigned to receive watthour meters that meet ANSI C12.10 Overhead or underground feed CONSTRUCTION Type 3R construction
More informationMetering and Service Installation:
Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...
More informationDesign Guide for Integration of Fixed-Mount Circuit Breakers
Design Guide Design Guide for Integration of Fixed-Mount Circuit Breakers WL Low Voltage Power Circuit Breakers www.usa.siemens.com/wlbreaker Contents Introduction... 3 Mounting... 3 Mounting Surface...
More informationApplication guide. Tmax Link OEM UL 891 Switchboard Program
Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit
More informationMeter Centers & Loadcenters Group Metering
June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through
More informationSelection and application guide
Selection and application guide For use in Tennessee Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More information5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets
.1 Metering Products Product Description Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac All Eaton sockets are rated All single meter sockets are 600 Vac maximum and either UL labeled and are