Contents. Volume 1 Residential and Light Commercial CA E December
|
|
- Antony Pitts
- 6 years ago
- Views:
Transcription
1 Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview Application Description Features and Benefits Standards and Certifications Catalog Number Selection Product Selection Accessories Renewal Parts Surface Units Pedestal Units Product Overview A power outlet panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and RV parks. POPs provide a safe and reliable means for users to access electricity at such locations. Product Description Power outlet panels shall be designed for outdoor service to meet temporary power outlet requirements at construction sites and provide high quality, economical power to individual sites at RV parks. POPs shall be provided with means to bond the neutral for temporary service entrance applications. RV panels shall have a factoryinstalled insulated neutral bar. Receptacles and Circuit Protection Circuit protection shall be Eaton s UL listed full-size Type BR or half-size Type BD circuit breakers. The receptacles shall be NEMA commercial/industrial grade devices. Ground fault protection (GFCB) shall be provided at the 20A duplex NEMA 5-20R receptacle or 20A single-pole circuit breaker when required. Ground fault protection shall be provided at the circuit breaker for receptacles above 20A when required. Construction The power outlet panel pedestal shall be of deadfront design and constructed of heavy gauge, 100 percent galvanized steel. Baked-on polyester powder coating shall be used for excellent mechanical strength, plus resistance to chalking caused by the sun s ultraviolet rays. The power outlet panel surface and pedestal units shall have NEMA Type 3R rainproof enclosures. Ease of Installation Panels shall ship from the factory completely assembled, prewired with 100 percent copper wire, and tested in accordance with UL Standard 231. The door shall swing up and open for user convenience and ease of access to breakers and receptacles. When required, a means for securing the door in the open position shall be provided. Panels shall be bottom fed through knockouts in endwall or top fed using a bolt-on raintight hub. Knockouts shall range from 1/2-inch (12.7 mm) to 1-1/2 inches (38.1 mm). Grounding provisions (#4 14 Cu/Al) shall be provided on all panels. Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
2 .2 Power Pedestals Application Description POPs are also sometimes called temporary power panels, temporary site service equipment or RV panels. Construction Site Application When POPs are used at a construction site, they are installed on a temporary basis until permanent electrical power is available at the building. The most common reason for needing a POP at a construction site is to provide a power source for the contractor s tools. RV Park Applications When POPs are used at an RV park, they are installed for more permanent use and serve the purpose of providing power to the recreational vehicles. Many RV parks now supply customers with amenities such as lighted POPs with TV and telephone jacks. Features and Benefits Designed for outdoor service to meet power outlet requirements Receptacles conform to NEMA and/or ANSI configurations as specified by the National Electrical Code (NEC) Includes a factory-installed insulated neutral bar with provisions for bonding when used for temporary service entrance applications 125A rated meter socket Temporary power and RV park POPs are CSA listed. Compact POP and single receptacle devices are not CSA listed Construction Site Application RV Park Application Service Applications Suitable for use as temporary Service Entrance Equipment, temporary power service equipment and recreational vehicle site supply. Designed for Easy Installation and Protection Panels come from the factory completely assembled, prewired with 100 percent copper wire and tested...ready for easy installation Door swings up and open for user convenience and ease of access to breakers and receptacles Panels can be bottom fed through knockouts in the endwall or top fed using a bolt-on raintight hub Two-piece deadfront cover allows field wiring without interfering with factory wiring Lower deadfront cover permits easy field wiring to circuit protective devices Available GFI (ground fault interrupter) single- and two-pole protection through 50A 288 Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
3 Power Pedestals.2 Two Styles to Meet Your Power Outlet Needs Surface mount: User mounts unit to a post Pedestal mount: User mounts with an underground pedestal extension or pad-mounting bracket. (Underground pedestal extension and pad-mounting bracket are sold separately. See accessories Page 291 for part numbers and options) Surface Units 100 percent galvanized steel with baked-on polyester powder coating Three-point mounting One-piece case back for metered and unmetered panels Lighted option for site location and nighttime panel operations NEMA 3R construction for rainproof installation Utility grade metering available for construction site or RV park applications Door swings up when opening and allows cords to remain connected when closed. Removable upper deadfront cover for easy incoming wire connections to breaker terminals GFI circuit breakers available through 50A Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked Lower deadfront cover can be removed for easy routing of incoming wires or receptacle changeouts Padlock provisions to prevent unauthorized entry Compact Design Available in Certain Configurations for Added Convenience Standards and Certifications UL Standard 231 UL File Number E13588 Receptacles conform to NEMA and/or ANSI configurations as specified by the NEC. Standard Compliance All power outlet panels for temporary construction site power and RV (recreational vehicle) application shall be UL listed for the U.S. per UL Standard 231, File E Receptacles shall conform to NEMA and/or ANSI configurations as specified by the National Electrical Code (NEC). Metered units available with meter on top or on bottom Pedestal Units 100 percent galvanized steel with baked-on polyester powder coating GFI circuit breakers (single- and two-pole) available through 50A One-piece case back for metered and unmetered panels Loop-feed lug assembly with 350 kcmil lugs included as standard Pedestal extension available for underground services Pad-mounted bracket option also available Units are factory wired and assembled NEMA 3R construction for rainproof installation Utility grade metering available for construction site or RV park applications Door swings up when opening and allows cords to remain connected when closed Removable upper deadfront cover for easy incoming wire connections to breaker terminals Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked Lower deadfront cover can be removed for easy routing of incoming wires or receptacle changeouts Padlock provisions to prevent unauthorized entry Units are factory wired and assembled Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
4 .2 Power Pedestals Catalog Number Selection Notes For receptacle configurations, see table below. Weather-resistant. Weather-resistant/tamper resistant. Receptacle Configuration 1 50A, 125/250V, three-pole, four-wire, NEMA 14-50R Two-pole, 50A breaker 3 30A, 125/250V, three-pole, four-wire, NEMA 14-30R Two-pole, 30A breaker 4 30A, 125V, two-pole, three-wire, NEMA TT-30R Single-pole, 30A breaker Twist-Lock and Custom Receptacle/Breaker Combinations A 1 = NEMA 14-50R 3 = NEMA 14-30R 4 = NEMA TT-30R 5 = NEMA -20R2 = NEMA 5-20R2 7 = NEMA 5-20R2GFI 8 = NEMA 5-20R2GFI 9 = NEMA 5-20R2GFI Eaton s Cutler-Hammer Series Metering Type U = Unmetered M = Metered-ring R = Metered-ringless Receptacle Type Left Position 50A, 125/250V, three-pole, three-wire, NEMA L14-50R Two-pole, 50A breaker B 50A, 250V, two-pole, three-wire, NEMA L-50R Two-pole, 50A breaker C 50A, 125V, two-pole, three-wire, NEMA L5-50R Single-pole, 50A breaker A = NEMA L14-50R B = NEMA L-50R C = NEMA L5-50R D = NEMA L14-30R E = NEMA L-30R F = NEMA L5-30R H = NEMA L-20R J = NEMA L5-20R Blank = No receptacle C H M 1 N 7 N 4 N P X L T Z U 5 20A, 250V, two-pole, three-wire, NEMA -20R2 Two-pole, 20A breaker 20A, 125V, two-pole, three-wire, NEMA 5-20R2 Single-pole, 20A breaker 7 20A, 125V, two-pole, three-wire, NEMA 5-20R2GFI D Receptacle Type Center Position See Receptacle Type Left Position for code selection Circuit Breaker Type Position 2 N = Non-ground fault G = Ground fault Circuit Breaker Type Position 1 N = Non-ground fault G = Ground fault Single-pole, 20A breaker 30A, 125/250V, three-pole, four-wire, NEMA L14-30R Two-pole, 30A breaker E 30A, 250V, two-pole, three-wire, NEMA L-30R Two-pole, 30A breaker F 30A, 125V, two-pole, three-wire, NEMA L5-30R Single-pole, 30A breaker Receptacle Type Right Position See Receptacle Type Left Position for code selection Circuit Breaker Type Position 3 N = Non-ground fault G = Ground fault Mounting Interior X = Six circuit Blank = Standard Four circuit S = Surface P = Pedestal B = Back-to-back pedestal Lighting L = Lighted 8 WR 20A, 125V, two-pole, three-wire, weather-resistant (WR), NEMA 5-20R2GFI 9 WR 20A, 125V, TR two-pole, three-wire, weather-resistant/ tamper-resistant (WR TR), NEMA 5-20R2GFI H 20A, 250V, two-pole, three-wire, NEMA L-20R Two-pole, 20A breaker J 20A, 125V, two-pole, three-wire, NEMA L5-20R Single-pole, 20A breaker Feed U = Bottom fed Blank =Top fed Pedestal Extension TZ= Factory installed pedestal extension with lay-in ground lug 290 Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
5 Power Pedestals.2 Product Selection When quoting or selecting a power outlet panel, the following questions should be answered: Unmetered, ring or ringless style Number and types of receptacles (seven standard and eight twist-lock options) Standard or ground fault breakers Surface, pedestal or back-to-back mounting Are any factory or field options required? Accessories Underground Pedestal Extension Pad-Mount Bracket Cable TV/Telephone Bracket DS Hub Fluorescent Light Kit Accessories Description Underground pedestal extension Fluorescent Light Kit Power Outlet Panel Receptacle Configuration Rules Four Receptacles/Unit All receptacles must be NEMA 5-20R2 or NEMA 5-20R2GFI, surface mount only. Three Receptacles/Unit One or more of the receptacles must be NEMA -20R2, NEMA 5-20R2 or NEMA 5-20R2GFI NEMA -20R2, NEMA 5-20R2, or NEMA 5-20R2GFI must go in the second position Stainless steel underground pedestal extension Pad-mount bracket Cable TV and telephone bracket Rainproof conduit hub 0.75 inch (19.1 mm) Rainproof conduit hub 1.00 inch (25.4 mm) Rainproof conduit hub 1.25 inch (31.8 mm) Rainproof conduit hub 1.50 inch (38.1 mm) Description Converts power outlet panel to lighted unit, must also order CHOUTCVRL If two receptacles consist of types NEMA 14-50R, NEMA 10-50R, NEMA 14-30R or NEMA -20R2 a six-circuit interior must be added Example: CHUIN5N2NSX Note: Configuration 1 and 2 were chosen so a six-circuit interior needs to be added (suffix X) to the end of the catalog number. Also, configuration 5 is in the second position. Two, One and Zero Receptacles/Unit Any configuration. Catalog Number CHPEDEXT CHPEDEXTSS CHPADEXT CHTELTV DS075H1 DS100H1 DS125H1 DS150H1 Catalog Number CHFLGTKIT Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
6 .2 Power Pedestals Renewal Parts Circuit Breaker (BR/GFCB) Meter Socket Bonding Strap and Mounting Hardware Inner Lens Loop Feed Lug Assembly Lower Deadfront Cover Renewal Parts Description See this volume, Tab 1, section 1.2 Ring style replacement meter socket Ringless style replacement meter socket 5th jaw kit Horn bypass (one lug cap per kit; four kits required per device) Bonding strap and mounting hardware Inner lens for lighted power outlet panels Loop feed lug assembly for single pedestal Loop feed lug assembly for back-to-back pedestal Blank lower deadfront cover Lower deadfront cover with duplex receptacle opening Lower deadfront cover with duplex, duplex receptacle opening Lower deadfront cover with duplex, duplex, duplex receptacle opening Lower deadfront cover with rectangle receptacle opening Lower deadfront cover with rectangle, rectangle receptacle opening Lower deadfront cover with rectangle, rectangle, rectangle receptacle opening Lower deadfront cover with duplex, rectangle receptacle opening Lower deadfront cover with duplex, rectangle, duplex receptacle opening Lower deadfront cover with rectangle, rectangle, duplex receptacle opening Lower deadfront cover with round receptacle opening Lower deadfront cover with round, round receptacle opening Lower deadfront cover with round, duplex receptacle opening Catalog Number CHPOPMSRING CHPOPMSRL ARP00035CHJ ARP00777CH CHBONDST CHINLENS CHLOOPFDP CHLOOPFDB CHLDFCVR CHLDFCVR1 CHLDFCVR2 CHLDFCVR3 CHLDFCVR4 CHLDFCVR5 CHLDFCVR CHLDFCVR7 CHLDFCVR8 CHLDFCVR9 CHLDFCVR10 CHLDFCVR11 CHLDFCVR Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
7 Power Pedestals.2 Upper Deadfront Cover Renewal Parts, continued Description Lower deadfront cover with round, duplex, duplex receptacle opening Lower deadfront cover with round, duplex, round receptacle opening Lower deadfront cover with round, rectangle receptacle opening Lower deadfront cover with round, rectangle, rectangle receptacle opening Lower deadfront cover with round, rectangle, round receptacle opening Lower deadfront cover with round, rectangle, duplex receptacle opening Upper deadfront cover with six breaker twistouts Upper deadfront cover with provisions for lighted option Catalog Number CHLDFCVR13 CHLDFCVR14 CHLDFCVR15 CHLDFCVR1 CHLDFCVR17 CHLDFCVR18 CHUDFCVR CHUDFCVRL Outer Door Outer door CHOUTCVR Outer Door with Lens Outer door with lens CHOUTCVRL Neutral Assemblies Six-hole neutral assembly with 2/0 lug Seven-hole neutral assembly with 2/0 lug CHNEUT CHNEUT1 Five-hole ground bar kit 10-hole ground bar kit Replacement Meter Cover Replacement meter cover ring type Replacement meter cover ringless Replacement meter cover ringless Replacement meter cover ringless GBK5 GBK10 CHPOPRMC CHPOPRLMC CHPOPRLMCN CHPOPRLMCN2 Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
8 .2 Power Pedestals Power Outlet Panels Surface Units Product Overview A power outlet panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and recreation vehicle (RV) parks. POPs provide a safe and reliable means for users to access electricity at such locations. Product Selection Contents Description Power Outlet Panel Receptacle Configuration Rules See Page 292 for complete Three Receptacles/Unit list. For 100A Main Breaker, contact the Flex Center ( ). Four Receptacles/Unit All receptacles must be NEMA 5-20R2 and/or NEMA 5-20R2GFI, surface mount only. Page Product Overview Surface Units Dimensions Pedestal Units One or more of the receptacles must be NEMA -20R2, NEMA 5-20R2 or NEMA 5-20R2GFI NEMA -20R2, NEMA 5-20R2, or NEMA 5-20R2GFI must go in the second position If two receptacles consist of types NEMA 14-50R, NEMA 10-50R, NEMA 14-30R or NEMA -20R2 a six-circuit interior must be added Example: CHUIN5N2NSX Note: Configuration 1 and 2 were chosen so a six-circuit interior needs to be added (suffix X) to the end of the catalog number. Also, configuration 5 is in the second position. Two, One and Zero Receptacles/Unit Any configuration. Options Six-circuit interior Factory-mounted pedestal extension Lighted Bottom fed 294 Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
9 Power Pedestals.2 Single Receptacle CHU4S Unmetered Type CHU1N7N4NS Unmetered (Compact Version) Surface Type Ampere Series Notes Receptacle Description Position Unmetered Single Receptacle Left Center Right The X suffix indicates that a six circuit interior is provided, instead of the standard four circuit interior. Includes 0A two-pole main breaker for service disconnect ratings. Contact your local Eaton sales office for configurations not listed. Breaker Description 1st 2nd 3rd Catalog Number R No breaker No breaker No breaker CHU1S R No breaker No breaker No breaker CHU3S 30 TT-30R No breaker No breaker No breaker CHU4S 20-20R2 No breaker No breaker No breaker CHU5S R2 No breaker No breaker No breaker CHUS R2GFI No breaker No breaker No breaker CHU7S Unmetered 20/20/ R2 5-20R2-20R2 GFI GFI GFI CHUGG5GS 20/20/ R2GFI 5-20R2GFI -20R2 Non-GFI Non-GFI Non-GFI CHU7N7N5NS 20/20/ R2GFI 5-20R2GFI -20R2 Non-GFI Non-GFI GFI CHU7N7N5GS 50/20/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NS 50/20/ R 5-20R2GFI -20R GFI Non-GFI Non-GFI CHU1G7N7NS 50/ R 5-20RGFI GFI Non-GFI CHU1G7NS 50/ R 5-20RGFI Non-GFI Non-GFI CHU1N7NS 50/20/ R 5-20R2GFI 14-50R Non-GFI Non-GFI Non-GFI CHU1N7N1NSX 30/30/20 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU4N7N4NS 20/20/ R2 5-20R2-20R2 GFI GFI GFI CHUGG5GSOM Unmetered (Compact Version) R Non-GFI CHU1NS R2 Non-GFI CHU2NS 30 TT-30R GFI CHU4GS 30/30 TT-30R TT-30R Non-GFI Non-GFI CHU4N4NS 30/20 TT-30R 5-20R2 Non-GFI Non-GFI CHU4NNS 30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHU4N7NS 30 TT-30R Non-GFI CHU4NS 20-20R2 GFI CHU5GS 20/ R2 5-20R2 GFI GFI CHUGGS R2 GFI CHUGS 20/ R2 5-20R2 Non-GFI Non-GFI CHUNNS R2 Non-GFI CHUNS 20/ R2GFI 5-20R2GFI Non-GFI Non-GFI CHU7N7NS R2GFI Non-GFI CHU7NS Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
10 .2 Power Pedestals Metered Ring CHM1G7NS Metered Ringless Type CHR4N7NS Metered Ring or Ringless Type Bottom Feed Accessories See Page 291. Surface Type, continued Ampere Series Metered Ring Receptacle Description Position Left Center Right Breaker Description 1st 2nd 3rd Catalog Number 50/20/ R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHM1G7N7NS 20/ R2GFI 5-20R2GFI Non-GFI Non-GFI CHM7N7NS 20/20/ R2GFI 5-20R2GFI -20R2 Non-GFI Non-GFI GFI CHM7N7N5GS 20/20/ R2GFI 5-20R2GFI -20R2 Non-GFI Non-GFI Non-GFI CHM7N7N5NS 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NS 50/ R 5-20R2GFI Non-GFI Non-GFI CHM1N7NS 20/20-20R2 5-20R2GFI Non-GFI Non-GFI Non-GFI CHM5N7NS Metered Ringless 50/ R 5-20R2GFI GFI Non-GFI CHR1G7NS 20/ R2GFI 5-20R2GFI Non-GFI Non-GFI CHR7N7NS 50/20/ R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHR1G7N7NS 50/ R 5-20R2GFI Non-GFI Non-GFI CHR1N7NS 20/20/ R2GFI 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR7N7N7NS 30/20/ R 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR3N7N7NS 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NS Metered Ring Bottom Fed 20/ R2GFI 5-20R2GFI Non-GFI Non-GFI CHM7N7NSU 20/20/ R2GFI 5-20R2GFI -20R2 Non-GFI Non-GFI GFI CHM7N7N5GSU 50/20/ R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHM1G7N7NSU Metered Ringless Bottom Fed 20/ R2GFI 5-20R2GFI Non-GFI Non-GFI CHR7N7NSU 50/ R 5-20R2GFI GFI Non-GFI CHR1G7NSU 50/ R 5-20R2GFI GFI Non-GFI CHR2G7NSU 20/20/ R2GFI 5-20R2GFI -20R2 Non-GFI Non-GFI GFI CHR7N7N5GSU 20/20/ R2GFI 5-20R2GFI -20R2 Non-GFI Non-GFI Non-GFI CHR7N7N5NSU 20/20/ R2GFI 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR7N7N7NSU 30/20/ R 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR3N7N7NSU 30/20/ R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHR3G7N7NSU 50/20/ R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHR1G7N7NSU 50/20/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NSU 29 Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
11 Power Pedestals.2 Dimensions Approximate Dimensions in Inches (mm) Single Receptacle 7.10 (108.3) 0.24 (.1) 4.50 (114.3) 1.30 (33.0).58 (17.1) 2.50 (3.5).23 (158.2) 4.79 (121.7) 2.3 (.8) 1.87 (47.5 ) 4.27 (108.5) 0.13 (3.3) 3.18 (80.8) Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
12 .2 Power Pedestals Approximate Dimensions in Inches (mm) Compact Design Option 0.30 (7.2) 11. (29.2) Unmetered Units.94 (17.3).58 (17.1) Unmetered Surface Type (434.3) Center Line for Receptacle 1.89 (48.0) 2.14 (54.4) (184.4) 2.43 (1.7) 4.27 (108.5) 0.13 (3.3) 4.89 (124.2) Locking Provision 4.30 (109.2) 0.07 (1.7).70 (170.2) (38.3) 1.30 (33.0) 298 Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
13 Power Pedestals.2 Approximate Dimensions in Inches (mm) Metered Units (Ring and Ringless) Metered Surface Type (72.0) Sealing Provision 9.50 Bottom Fed Type (74.) 9.49 (241.1) (571.5).15 (15.2) Sealing Provision Locking Provision (434.7) Locking Provision (329.4).80 (172.8) 4.31 (109.5) 4.93 (125.2) 4.50 (114.3) 4.30 (170.1) Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
14 .2 Power Pedestals Power Outlet Panels Pedestal Units Product Overview A power outlet panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and recreation vehicle (RV) parks. POPs provide a safe and reliable means for users to access electricity at such locations. Product Selection Contents Description Power Outlet Panel Receptacle Configuration Rules See Page 292 for complete Three Receptacles/Unit list. For 100A Main Breaker, contact the Flex Center ( ). Four Receptacles/Unit All receptacles must be NEMA 5-20R2 and/or NEMA 5-20R2GFI, surface mount only. Page Product Overview Surface Units Pedestal Units Dimensions One or more of the receptacles must be NEMA -20R2, NEMA 5-20R2 or NEMA 5-20R2GFI NEMA -20R2, NEMA 5-20R2, or NEMA 5-20R2GFI must go in the second position If two receptacles consist of types NEMA 14-50R, NEMA 10-50R, NEMA 14-30R or NEMA -20R2 a six-circuit interior must be added Example: CHUIN5N2NSX Note: Configuration 1 and 2 were chosen so a six-circuit interior needs to be added (suffix X) to the end of the catalog number. Also, configuration 5 is in the second position. Two, One and Zero Receptacles/Unit Any configuration. Options Six-circuit interior Factory-mounted pedestal extension Lighted Bottom fed 300 Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
15 Power Pedestals.2 Unmetered Type CHM1N7N4NPTZ CHU1N7N4NBTZ Accessories See Page 291. Pedestal Type Ampere Series Unmetered Back-to-Back Pedestal Type Notes Receptacle Description Position Left Center Right The pedestal back-to-back units have receptacles and circuit breakers as shown for each panel and share one common pedestal with loop feed lugs. Contact your local Eaton sales office for configurations not listed. Breaker Description 1st 2nd 3rd Catalog Number 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NP 30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHU4N7NP 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NPTZ 30/30/20 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU4N7N4NP 30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHU4N7NPTZ Metered Ring 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NP 50/ R 5-20R2GFI Non-GFI Non-GFI CHM1N7NP 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NPTZ 30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHM4N7NPTZ Metered Ringless 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NP 50/20/ R 5-20R2GFI 14-50R Non-GFI Non-GFI Non-GFI CHR1N7N1NPX 50/20/ R 5-20R2GFI 14-30R Non-GFI Non-GFI Non-GFI CHR1N7N3NPX 50/20/ R 5-20R R Non-GFI Ground fault Non-GFI CHR1NG3NPX Ampere Series Unmetered Receptacle Description Position Left Center Right Breaker Description 1st 2nd 3rd Catalog Number 30/30/20 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU4N7N4NB 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NBTZ Metered Ring 30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHM4N7NB 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NB Metered Ringless 50/30/ R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NBTZ Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
16 .2 Power Pedestals Dimensions Approximate Dimensions in Inches (mm) Metered Units 100A Pedestal wer Barrier.79 (20.1) (273.7) 4.00 Ringless U.G. Feed Pedestal-Mount ) Hit Exit Hole B/B Only (457.7) (838.2).92 (23.4) (838.2) Gasket Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
17 Power Pedestals.2 Approximate Dimensions in Inches (mm) Metered Units (Ring and Ringless) Metered Back-to-Back Pedestal Type Bottom Fed Type (74.) 9.49 (241.1).15 (15.2) Sealing Provision Locking Provision (434.7) (329.4).80 (172.8) 4.31 (109.5) 4.93 (125.2) 0.75 (19.1) 0.0 Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
18 .2 Power Pedestals Approximate Dimensions in Inches (mm) Unmetered Back-to-Back Pedestal Type 13.0 (345.4) Locking Provision (487.7) Unmetered Pedestal Type 9.50 (241.3) 0.75 (19.1) 3.30 (83.8) Metered Pedestal Type 9.50 (241.3) 5.00 (127.0).80 (172.7) 4.30 (109.2) (993.1) (1013.5) (1320.8) Locking Provision (1130.3) 9.20 (233.7) 9.40 (238.8) (55.3) Sealing Provision 1.90 (429.3) (558.8) 304 Volume 1 Residential and Light Commercial CA E December For Immediate Delivery or Tech Support call KMParts.com at (8)
19 Index A above, 1 access, 1-2, 8, 14 Accessories, 1, 5, 10, 15 accessories, 3 accordance, 1 Added, 3 added, 5, 8, 14 Al, 1 All, 3, 5, 8, 14 all, 1 allows, 2-3 Also, 5, 8, 14 also, 2-3, 5 amenities, 2 Ampere, 9-10, 15 an, 2-3 and, 1-18 ANSI, 2-3 answered, 5 Any, 5, 8, 14 any, 5 Application, 1-2 application, 3 Applications, 2 applications, 1-3 Approximate, 11-13, Are, 5 are, 2-3 ARP, as, 2-3, 15 assembled, 1-3 Assemblies, 7 Assembly, assembly, 3, -7 at, 1-18 Available, 2-3 available, 2-3 B Back, 4, 15, back, 3, 5-, 15 backpedestal, 4 Baked, 1 baked, 3 bar, 1-2, 7 Barrier, 1 barrier, 3 basis, 2 BD, 1 be, 1-3, 5, 8, 14 below, 4 Benefits, 1 BenefitsPOPs, 2 Blank, 4, bolt, 1-2 bond, 1 Bonding, bonding, 2 Bottom, 4, 8, 10, 13-14, 17
20 Index bottom, 1-3 BR, 1, Bracket, 5 bracket, 3, 5 Breaker, 4,, 8-10, breaker, 1, 3-4, 7, 9 breakers, 1-3, 5, 15 building, 2 by, 1-3 bypass, C CA, 1-18 Cable, 5 call, 1-18 called, 2 can, 2-3 cap, case, 3 Catalog, 1, 4-7, 9, 15 catalog, 5, 8, 14 CatalogSeries, 10 caused, 1 Center, 4, 8-10, 12, Certain, 3 Certifications, 1, 3 CH, chalking, 1 changeouts, 3 CHBONDST, CHFLGTKIT, 5 CHINLENS, CHJ, CHLDFCVR, -7 CHLOOPFDB, CHLOOPFDPLug, CHM, 10, 15 CHNEUT, 7 chosen, 5, 8, 14 CHOUTCVR, 7 CHOUTCVRL, 5, 7 CHPADEXT, 5 CHPEDEXT, 5 CHPEDEXTSS, 5 CHPOPMSRING, CHPOPMSRL, CHPOPRLMC, 7 CHPOPRLMCN, 7 CHPOPRMC, 7 CHR, 10, 15 CHTELTV, 5 CHU, 9, 15 CHUDFCVR, 7 CHUDFCVRL, 7 CHUIN, 5, 8, 14 circui, 4 Circuit, 1, 4, circuit, 1-5, 8-9, closed, 3 coating, 1, 3 Code, 2-3 code, 4 com, 1-18 CombinationsA, 4 come, 2 Commercial, 1-18 commercial, 1 common, 2, 15 Compact, 2-3, 9, 12 complete, 8, 14 completely, 1-2 Compliance, 3 conduit, 5 Configuration, 4-5, 8, 14 configuration, 5, 8, 14 Configurations, 3 configurations, 2-4, 9, 15 conform, 2-3 connected, 3 connections, 3 consist, 5, 8, 14 constructed, 1 Construction, 1-2 construction, 1-3, 8, 14 Contact, 9, 15 contact, 8, 14 Contents, 1, 8, 14 continued, 7 continuedreceptacle, 10 contractor, 2 Convenience, 3 convenience, 1-2 Converts, 5 copper, 1-2 cords, 3 Cover, -7 cover, 2-3, -7 CSA, 2 Cu, 1 Custom, 4
21 Index customers, 2 Cutler, 4 D Deadfront, -7 deadfront, 1-3, -7 December, 1-18 Delivery, 1-18 Description, 1-2, 5-10, Design, 3, 12 design, 1 Designed, 2 designed, 1, 8, 14 device, 1,, 8, 14 devices, 1-2 Dimensions, 8, 11-14, 1-18 DimensionsApproximate, 1 disconnect, 9 Door, 2-3, 7 door, 1, 3, 7 DS, 5 duplex, 1, -7 E each, 15 Ease, 1 ease, 1-2 Easy, 2 easy, 2-3 Eaton, 1, 4, 9, 15 eaton, 1-18 economical, 1 eight, 5 eld, 5 Electrical, 2-3 electrical, 2 electricity, 1, 8, 14 enclosures, 1 end, 5, 8, 14 endwall, 1-2 Entrance, 2 entrance, 1-2 entry, 3 Equipment, 2 equipment, 2 ersion, 9 Example, 5, 8, 14 excellent, 1 Exit, 1 Extension, 5 extension, 3-5 extensionnema, 8, 14 ExtensionU, 4 F Factory, 4, 8, 14 factory, 1-3, 5 fault, 1-2, 4-5, 15 Features, 1-2 Fed, 10, 13, 17 fed, 1-2, 4, 8, 14 Feed, 4,, 10, 1 feed, 3,, 15 fi, 5 field, 2 File, 3 Five, 7 Flex, 8, 14 Fluorescent, 5 following, 5 For, 1-18 for, 1-4, -9, 12, Four, 4-5 four, 4,, 9 from, 1-2 full, 1 G galvanized, 1, 3 Gasket, 1 gauge, 1 GBK, 7 GFCB, 1, GFI, 2-5, 8-10, 14-15
22 Index go, 5, 8, 14 grade, 1, 3 Ground, 1, 4, 15 ground, 2, 4-5, 7 Grounding, 1 GS, 9-10 GSU, 10 insulated, 1-2 interfering, 2 Interior, 4 interior, 5, 8-9, 14 interiorusers, 8, 14 interrupter, 2 is, 1-3, 5, 8-9, 14 H half, 1 Hammer, 4 Hardware, hardware, have, 1, 15 heavy, 1 high, 1 Hit, 1 Hole, 1 hole, 7 Horn, Hub, 5 hub, 1-2, 5 I If, 5, 8, 14 Immediate, 1-18 in, 1-5, 8, 11-14, 1-18 inch, 1, 5 Inches, 11-13, 1-18 inches, 1 included, 3 Includes, 2, 9 incoming, 3 indicates, 9 individual, 1 industrial, 1 Inner, Installation, 1-2 installation, 3 installationtemporary, 2 installed, 1-2, 4 instead, 9 J jacks, 2 jaw, K kcmil, 3 Kit, 5 kit, -7 kits, KMParts, 1-18 Knockouts, 1 knockouts, 1-2 L lay, 4 Left, 4, 9-10, 15 Lens, -7 lens, -7 Light, 1-18 Lighted, 3-4, 8, 14 lighted, 2, 5-7 Lighting, 4 Line, 12 list, 8, 14 listed, 1-3, 9, 15 local, 9, 15 location, 3 locations, 1, 8, 14
23 Index Lock, 4 lock, 5 Locking, 13, LockingProvision, 12, 18 Loop, 3, loop, 15 Lower, 2-3, -7 lower, lug, 3, -7 lugreceptacle, 4 lugs, 3, 15 M Main, 8, 14 main, 9 Many, 2 means, 1, 8, 14 mechanical, 1 Meet, 3 meet, 1-2, 8, 14 Meter, -7 meter, 2-3, -7 Metered, 3-4, 10, 13, metered, 3 Metering, 4 metering, 3 mm, 1, 5, 11-13, 1-18 more, 2, 5, 8, 14 most, 2 Mount, 5, 1 mount, 3, 5, 8, 14 mounted, 3, 8, 14 Mounting, 4, mounting, 3, 5- mounts, 3 must, 5, 8, 14 N National, 2-3 NB, 15 NBTZ, 15 nd, 9-10, 15 NEC, 2-3 needing, 2 Needs, 3 needs, 5, 8, 14 NEMA, 1-5, 8, 14 Neutral, 7 neutral, 1-2, 7 nighttime, 3 No, 4, 9 Non, 4, 9-10, 15 not, 2, 9, 15 Note, 5, 8, 14 Notes, 4, 9, 15 now, 2 NP, 15 NPTZ, 15 NPX, 15 NS, 9-10 NSU, 10 NSX, 5, 8-9, 14 Number, 1, 3-7, 9-10, 15 number, 5, 8, 14 numbers, 3 O of, 1-3, 5, 8-9, 14 office, 9, 15 OM, 9 on, 1-3 One, 3, 5, 8, 14 one,, 15 Only, 1 only, 5, 8, 14 open, 1-2 opening, 3, -7 operation, 3 operations, 3 Option, 12 option, 3, 7 options, 3, 5 OptionsFour, 8, 14 or, 1-18 order, 5 outdoor, 1-2, 8, 14 Outer, 7 Outlet, 1, 3, 5, 8, 14 outlet, 1-3, 5-, 8, 14
24 Index Overview, 1, 8, 14 ovision, 13 P Pad, 3, 5 pad, 3 Padlock, 3 padlocked, 3 Page, 1, 3, 8, 10, Panel, 5, 8, 14 panel, 1, 3, 5, 8, Panels, 1-2, 8, 14 panels, 1-3, Park, 1-18 park, 2-3 parks, 1-2, 8, 14 part, 3 Parts, 1, -7 Pedestal, 1, 3-5, 8, pedestal, 1, 3-, 8, Pedestals, 1-18 per, 3, percent, 1-3 permanent, 2 permits, 2 piece, 2-3 plus, 1 point, 3 pole, 1-4, 9 polyester, 1, 3 POP, 1-2, 8, 14 POPs, 1-2, 8, 14 Position, 4, 9-10, 15 position, 1, 5, 8, 14 post, 3 powder, 1, 3 Power, 1-18 power, 1-3, 5-, 8, 14 Pr, 13 prevent, 3 prevents, 3 prewired, 1-2 Product, 1, 5, 8, 14 Protection, 1-2 protection, 1-2 protective, 2 provide, 1-2, 8, 14 provided, 1, 9 providing, 2 Provision, 13, provisions, 1-3, 7 purpose, 2 Q quality, 1 questions, 5 quoting, 5 R Rainproof, 5 rainproof, 1, 3 raintight, 1-2 range, 1 rated, 2 ratings, 9 rays, 1 rd, 9-10, 15 ready, 2 reason, 2 Receptacle, 4-5, 8-9, 11-12, receptacle, 1-4, -7 Receptacles, 1-3, 5, 8, 14 receptacles, 1-2, 5, 8, recreation, 8, 14 recreational, 2-3 rectangle, -7 reliable, 1, 8, 14 remain, 3 Removable, 3 removed, 3 Renewal, 1, -7 Replacement, 7 replacement, required, 1, 5- requirements, 1-2, 8, 14 Residential, 1-18 resistance, 1 resistant, 4 RGFI, 9
25 Index Right, 4, 9-10, 15 Ring,, 10, 13, 15, 17 ring, 4-5, 7 RingCHM, 10 Ringless,, 10, 13, ringless, 4-5, 7 RinglessCHR, 10 round, -7 routing, 3 Rules, 5, 8, 14 RV, 1-18 S safe, 1, 8, 14 sales, 9, 15 Sealing, 13, second, 5, 8, 14 section, securing, 1 See, 3-4,, 8, 10, see, 4 selecting, 5 Selection, 1, 4-5, 8, 14 selection, 4 separately, 3 Series, 4, 9, 15 serve, 2 Service, 2 service, 1-2, 8-9, 14 services, 3 Seven, 7 seven, 5 shall, 1, 3 share, 15 ship, 1 should, 5 shown, 15 Single, 4, 9, 11 single, 1-3, Site, 2 site, 2-3 sites, 1, 8, 14 Six, 4, 7-8, 14 six, 5, 7-9, 14 size, 1 so, 5, 8, 14 Socket, socket, 2, sold, 3 sometimes, 2 source, 2 specified, 2-3 st, 9-10, 15 Stainless, 5 Standard, 1, 3-5 standard, 3, 5, 9 Standards, 1, 3 steel, 1, 3, 5 Strap, strap, strength, 1 style, 5- Styles, 3 such, 1-2, 8, 14 suffix, 5, 8-9, 14 Suitable, 2 sun, 1 supply, 2 Support, 1-18 Surface, 1, 3, 5, 8-10, surface, 1, 5, 8, 14 SurfaceG, 4 swing, 1 swings, 2-3 T Tab, table, 4 tamper, 4 Tech, 1-18 Telephone, 5 telephone, 2, 5 Temporary, 1-18 temporary, 1-3, 8, 14 terminals, 3 tested, 1-2 th, that, 9 The, 1-2, 9, 15 the, 1-3, 5, 8-9, 14 they, 2 this, Three, 3, 5, 8, 14 three, 4
26 Index through, 1-3 to, 1-, 8, 14-15, tools, 2 Top, 4 top, 1-3 TR, 4 TRthree, 4 TT, 4, 9-10, 15 TV, 2, 5 Twist, 4 twist, 5 twistouts, 7 Two, 2-5, 8, 14 two, 2-5, 8-9, 14 Type, 1, 4, 9-10, 12-13, 15, type, 7 types, 5, 8, 14 TZ, 4 U UL, 1, 3 ultraviolet, 1 unauthorized, 3 Underground, 3, 5 underground, 3, 5 Unique, 3 Unit, 5, 8, 14 unit, 3, 5 Units, 1, 3, 8, 12-14, 1-17 units, 1, 3, 15 Unmetered, 4-5, 9, 12, 15, 18 unmetered, 3 until, 2 up, 1-3 Upper, 7 upper, 3 use, 2 used, 1-2 User, 3 user, 1-2 users, 1 using, 1-2 Utility, 3 V vehicle, 2-3, 8, 14 vehicles, 2 Version, 9 Volume, 1-18 volume, W Weather, 4 weather, 4 wer, 1 were, 5, 8, 14 When, 1-2, 5 when, 1-3 wire, 1-4 wired, 3 wires, 3 wiring, 2 with, 1-4, -7, 15 without, 2 WR, 4 www, 1-18 Y Your, 3 your, 9, 15 ype, 13 Z Zero, 5, 8, 14
6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationVolume 1 Residential and Light Commercial CA E December
Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application
More informationPower Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................
More information6.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................
More informationPower Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationTemporary Power Outlet Panels
Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More information!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages
FILE: Distribution Product Catalog!!IERVICEB.aJC Power Outlet Panels CONTENTS Description Class Pages Application Data.......................... 1140........ 36 Dimensions................................
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42
More information5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets
.1 Metering Products Product Description Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac All Eaton sockets are rated All single meter sockets are 600 Vac maximum and either UL labeled and are
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals
Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal
DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)
More informationMP Meter-Pak Meter Centers
Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application
More informationMetering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering
Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal
More informationWisconsin Area Catalog
Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationGeneral Specifications for Lighthouse Power Pedestal
Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION
More informationSection 6 Electric Metering: Residential
Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.
More informationCP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long
More information5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.11 Metering Products Systems for Residential and Commercial Application Systems for Residential and Commercial Applications Product Description Group metering is a service entrance product line that consists
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More informationStandard switch modules (type WS) are designed for flexibility, space savings, & durability.
Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800
More informationEquipment. Metering. Metering Equipment 1. Contents
1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More informationMidwest Electric Products. Temporary Power
Midwest Electric roducts Temporary ower Midwest Electric roducts Temporary ower Midwest Electric provides the temporary power needed by construction trades prior to permanent service equipment installation.
More informationDisconnects. Product Description
Spa Panels............................. 6-1 Air Conditioner Metallic and............... 6-5 With Ground Fault Receptacle............ 6-6 With Whips.......................... 6-6 Three-Phase..........................
More informationCutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF
Cutler-Hammer Breakers American International Marketing Portland OR 97291-033 Closeout #1287-Cutler-Hammer-Breakers Cutler Hammer Ground-Fault Or Arc-Fault Breaker GFEP120 Cutler Hammer Ground-Fault Equipment
More informationMeter Mounting Equipment Wisconsin Area
Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationMEG Approval Meter Equipment Group
MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationEquipment. Metering. Metering Equipment 1. Contents
1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................
More informationAir Conditioning Disconnects
.1 Product Description............................................. 2 Application Description........................................... 2 Features, Benefits and Functions...................................
More informationSelection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting
Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals
Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41
More informationContents. General Electric Sangamo Astra CTB JCT-10 R6B TAB, TA CSF JCM-0 R6BA TCB, AA CMF JCW-0 R6M AB
Panelboards and Lighting Control Metering Service Sections.7 Metering Service Section Contents Description Metering Service Sections Page Catalog Number Selection........................ 482 Product Selection..............................
More informationPower Outlets. Application Information. Features and Benefits. For Farm, Home and Industry U010C
Power Outlets 60 Power Outlets For Farm, Home and Industry Application Information Portable equipment requiring electricity continues to increase steadily in both number and variety. This creates the need
More informationDuke/MEG Approval Meter Equipment Group
Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides
More informationMeter Mounting Equipment DTE Energy Area
Meter Mounting Equipment DTE Energy Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationModular Metering Application Guide
GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III
More information5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection
.11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box
More informationDry-Type Transformers Mini-Power Centers
Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More informationModular Metering Construction Details
GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single
More informationPower Mod. Introduction.
Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination
More informationU075CTL A Surface 50/30/20GFCI Twin Lugs
3804 South Street 75964-7263, TX Nacogdoches hone: 936-569-794 Fax: 936-560-4685 llenwatson@elliottelectric.com U075TL00 00 Surface 50/30/20GFI Twin Lugs Midwest Electric roducts atalog Number Manufacturer
More informationMeter Mounting Equipment. GA/AL/FL Panhandle Area
Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationREC Municipal Meter Mounting Equipment
REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationMeter Centers & Loadcenters Group Metering
June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through
More informationIndiana Meter Mounting Equipment
Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center
Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"
More informationMetering NEED. Meter Sockets. Product Description
Meter Sockets Meter Sockets Single Position (Ring, Ringless and Bypass)........ - Multiple Position Without Tenant Main Breakers.......... - Accessories.......................... -7 Meter Packs (All-in-Ones)
More informationMeter Mounting Equipment Florida Area Catalog
Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert
More informationComEd Service Area Meter Mounting Equipment
ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs
More informationOhio Meter Mounting Equipment
Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationSERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company
More informationSingle Socket and Horizontal Metering
G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More information7. Residential Single-Family and Duplex Buildings (Dwellings)
Sin g le -F a mily a n d Du p le x Bu ild in g s 2016 Electric Service Requirements, 2 nd Edition Section 7 Section 7 Residential Single-Family and Duplex Buildings (Dwellings) Directory Page 7.1 General
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At
More information3.1. Residential Standby Power. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.1 Residential Standby Power Transfer Switch Panels All Panels are Manufactured in the USA and Meet UL 1008 Product Description A transfer switch panel is a device that is mounted next to the loadcenter
More informationSection 4 Square D QO Loadcentres
Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and
More informationALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight
ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards
More informationPower Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module
Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module
More information1.1. Switching Devices
. Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................
More informationSingle Socket and Horizontal Metering
Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential
More informationWPS SERVICE MANUAL. Section Amp and Smaller - Common
Revised 01/2017 Section 2 200 AMP AND SMALLER - COMMON Page 1 of 17 Section 2 200 Amp and Smaller - Common 2-0 General Metering Requirements... 2 2-1 Basic Calculations... 4 2-2 100-200 Amp Single-Phase
More informationNew Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment
New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
More informationLouisiana/Mississippi. Area Catalog
Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationEngine Generator Circuit Breakers
Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................
More informationHeavy Duty Safety Switches
eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................
More information25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,
More information1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX
LAD05-9, CA 964 TITLE SHEET LAD05-9 SHEET INDEX 00 DEXTER AVE. SUITE 50 SEATTLE, WA 9809 PROJECT SUMMARY PROJECT DESCRIPTION COORDINATES LATITUDE: 33.678084 N LONGITUDE: -7.84858 W 0640 Sepulveda Blvd.
More informationSECTION 500 METERING AND ASSOCIATED EQUIPMENT
SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.
More informationDivision 1 Explosionproof Panelboards
Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting
More informationMicrolectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units
Microlectric CO Series Meter sockets A complete family of combination meter sockets and breaker units Outdoor, above-ground main breaker access increases safety Table of Contents Introduction... 3 Microlectric
More informationNew England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that
More informationUNDERGROUND SERVICES - SECONDARY
UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service
More informationX1PB: Explosionproof Panelboards
X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel
More informationDesign Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak
Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers
More informationSelection and application guide
Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure
More informationSTOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION
CHAPTER 1 - GENERAL INFORMATION 100. Purpose 101. Codes and rules 102. Continuity of service 103. Frequency, Voltage, and Amperage Limitations 104. High voltages 105. Unusual capacity requirements 106.
More informationP-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.
ALN, AN and AGN Series: Non-Factory Sealed. -9 Applications Distribution panelboards are used to furnish protection and control of electrical equipment in hazardous locations. These compact units provide
More informationLighthouse Power Pedestals,
Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized
More informationCON EDISON EQUIPMENT
CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200
More informationEylander Electric Inc
Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL
More information24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)
.4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both
More information