Power Outlets. Application Information. Features and Benefits. For Farm, Home and Industry U010C

Size: px
Start display at page:

Download "Power Outlets. Application Information. Features and Benefits. For Farm, Home and Industry U010C"

Transcription

1 Power Outlets 60

2 Power Outlets For Farm, Home and Industry Application Information Portable equipment requiring electricity continues to increase steadily in both number and variety. This creates the need for conveniently located receptacles to provide power for cord connected equipment. Midwest Electric Power Outlets provide one or more receptacles, with or without overcurrent protection, in a single enclosure eliminating the need for several separately mounted components while providing maximum protection against weather and normal field use. Additionally, many models are offered that also include disconnecting, metering, and/or pedestal mounting functions in a single NEMA 3R enclosure/assembly. Features and Benefits Features G90 galvanized steel with superior electro-deposition paint finish provides excellent corrosion protection All in one construction for factory assured terminations Rolled edge door for cord protection Cover design allows cords to exist while maintaining the NEMA 3R integrity Wide assortments of concentric knockouts offer flexibility in the installation Benefits Padlockable door to help prevent unauthorized access Dead front construction prevents accidental contact with live parts Listed by Underwriter Laboratories All components factory wired and assembled reducing installation time U010C Temp Power / Power Outlets U For Wire Range or Cabinet Tables see Application Data Section. U013C 61

3 Power Outlets - Surface (2) 10-50R 5-20R2 (2) 14-50R 5-20R2GFI (2) 14-50R 5-20R2 5-20R2 5-20R2GFI 5-20R2 5-20R2 A U002C B U004CTL010 C U004F D U010 E U010C F U010F Power Outlets R2 G U010H 5-20R2GFI (2) 5-20R2 (2) 5-20R2 (2) 5-20R2GFI R32U H U I U011 J U011F K U L U013 Surface - Unmetered FIG. UL MODEL NUMBER RECEPTACLES CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION AMP VOLTS RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. A N U002C (2) 10-50R 5-20R2 (2) CB250 CB /240 U 14 X 21 Y LC55N B Y U004CTL010 (2) 14-50R 5-20R2GFI (2) CB250 CB /240 W 9 X 17 Y LC55N1T 17 1 C Y U004F (2) 14-50R 5-20R2 FH /240 U 14 X 21 Y FR64X D Y U R E 5 X 7 Y E Y U010C 5-20R2 CB B 6 X 9 Y LC31N3 7 4 F Y U010F 5-20R2 FH E 5 X 7 Y G Y U010H 5-20R2 FH2, SP SWITCH E 5 X 7 Y 5 4 H Y U R2GFI E 5 X 7 Y I Y U011 (2) 5-20R E 6 X 9 Y 7 4 J Y U011F (2) 5-20R2 (2) FH /240 E 6 X 9 Y 9 4 K Y U (2) 5-20R2GFI /240 E 6 X 9 Y 9 4 L Y U013 R32U F 5 X 7 Y * Wire Range Table on page 70 62

4 Power Outlets - Surface R32U R32U (4) 5-20R2GFI 7310 R32U 5-20R2 R32U 5-20R2 A U013C B U013F C U014C010 D U023 E U041 F U041C Temp Power / Power Outlets R32U 5-20R R 10-50R 10-50R 5-20R R 14-50R G U041F H U050 I U050C J U051F K U054 L U054F Surface - Unmetered FIG. UL MODEL NUMBER RECEPTACLES CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION AMP VOLTS RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. A Y U013C R32U CB A 6 X 9 Y LC31N3 7 4 B Y U013F R32U FH F 5 X 7 Y C Y U014C010 1 (4) 5-20R2GFI (4) CB /240 U 14 X 21 Y LC55N D N U /240 F 5 X 7 Y E Y U041 R32U /240 E 6 X 9 Y R2 R32U CB130 F Y U041C 5-20R2 CB /240 P 6 X 14 Y LC33N G Y U041F R32U FH3, FH /240 E 6 X 9 Y R2 H N U R /240 G 5 X 7 Y I N U050C 10-50R CB /240 O 6 X 14 Y LC33N J N U051F 10-50R FH /240 P 6 X 14 Y FR R2 K Y U R /240 G 5 X 7 Y 5 4 L Y U054F 14-50R /240 K 6 X 14 Y FR Earth Burial Model U014CP6010 * Wire Range Table on page 70 63

5 Power Outlets - Surface 14-50R 5-20R R R32U (2) R32U (2) R32U 10-50R R R BR32U 5-20R2 A U055F B U058C 2 C U061C 2 D U061CTL E U070C F U075C Power Outlets 3 R32U 14-50R 14-60R 14-60R (2) 5-20R2 G U132CTL H U154F I U354C J U546 K U361G 6-50R L U501 Surface - Unmetered FIG. UL MODEL NUMBER RECEPTACLES CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION AMP VOLTS RANGE* SIZE OPENING NEUTRAL BAR WT. PKG R A Y U055F 5-20R /240 K 6 X 14 Y FR B Y U058C R R32U CB130 CB /240 P 9 X 17 Y LC33N C Y U061C 1 (2) R32U (2) CB /240 P 6 X 14 Y LC33N D Y U061CTL (2) R32U (2) CB /240 P 9 X 17 Y LC33N1T 14 1 E N U070C 10-50R, 7310, 5-20R2 CB250 CB220 CB /240 U 9 X 17 Y LC55N F U075C 14-50R, BR32U CB250, CB130, CB /240 U 9 X 17 Y LC55N Y 5-20R2 G Y U132CTL R32U CB /240 P 9 X 17 Y LC33N1T 11 1 SPACE (2) CB120 H Y U154F 14-50R /240 Z 14 X 21 Y FHL101-FR I Y U354C 14-50R CB /240 P 9 X 17 Y LC55N SPACE (3) CB120 J N U R /240 G 6 X 9 Y 5 4 K Y U361G (2) 5-20R2 GFI /240 P 6 X 14 Y L Y U R P 5 X 7 Y Model Number is also suitable for use as Temporary Site Service Equipment when installed in accordance with the N.E.C. * Wire Range Tables on pages 34, 58, 70 64

6 Power Outlets - Surface 6-50R 5-20R2 6-50R 5-20R R 5-20R2 (2) R32U (2) BR32U A U511C B U511G C U550F D U614C Temp Power / Power Outlets L6-30R (2) L5-20R 14-50R R32U 14-50R E U870G F R058C G M354C Surface - Unmetered FIG. UL MODEL NUMBER RECEPTACLES A Y U511C B Y U511G 6-50R CB R2 CB R CB R2 GFI120 CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION AMP VOLTS RANGE* SIZE OPENING NEUTRAL BAR WT. PKG /240 P 6 X 14 Y LC33N /240 P 6 X 14 Y LC33N7 1 4 C Y U550F 14-50R 5-20R2 FH /240 M 6 X 14 Y 6 4 D Y U614C 1 (2) R32U (2) BR32U (4) CB /240 P 14 X 21 Y LC55N E Y U870G Surface - Metered FIG. UL MODEL NUMBER RECEPTACLES L6-30R CB230 (2) GFI120 (2) L5-20R F Y R058C 14-50R CB R32U CB /240 P 9 X 17 Y LC55N CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. AMP VOLTS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG /240 P 9 X 30 Y LC33N G Y M354C 14-50R CB P 9 X 30 Y LC55N SPACE (3) CB120 1 Model Number is also suitable for use as Temporary Site Service Equipment when installed in accordance with the N.E.C. + Also Available in Ring Type - Replace R with M. * Wire Range Table on page 70 65

7 Power Outlets - Pedestal 14-50R R32U R32U (2) R32U 14-50R R32U R32U (2) R32U A U058CP6 2 B U132CP6 2 C U061CP6 2 D U058CB6 E U132CB6 2 F U061CB6 2 Power Outlets R R32U R32U 14-50R 14-50R R32U R32U 14-50R G R058CP6 2 H M132CP6 2 I M354CP6 J R058CB6 K M132CB6 L M354CB6 Pedestal - Unmetered FIG. UL MODEL NUMBER RECEPTACLES CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION AMP VOLTS RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. A Y U058CP R R32U CB250 CB /240 T2 9PT N LC33N B Y U132CP6 2 R32U CB130 SPACE (2) CB /240 T2 6PT N LC33N C Y U061CP6 2 (2) R32U (2) CB /240 T2 6PT N LC33N Pedestal - Unmetered Back to Back FIG. UL MODEL NUMBER RECEPTACLES D Y U058CB6 E Y U132CB6 2 R32U F Y U061CB6 2 (2) R32U Pedestal - Metered 14-50R CB250 R32U CB130 CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION AMP VOLTS RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. CB130 SPACE (2) CB120 (2) CB /240 S 9PT N LC33N /240 S 6PT N LC33N /240 S 6PT N LC33N FIG. UL MODEL NUMBER RECEPTACLES CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION AMP VOLTS RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. G Y R058CP R R32U CB250 CB /240 T2 9PT N LC33N H Y M132CP6 2 R32U CB130 SPACE (2) CB /240 T2 9PT N LC33N I Y M354CP R CB250 SPACE (3) CB /240 T2 9PT N LC55N Pedestal - Metered Back to Back FIG. UL MODEL NUMBER RECEPTACLES CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION AMP VOLTS RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. J Y R058CB R CB R32U CB /240 S 9PT N LC33N K Y M132CB6 R32U L Y M354CB R CB130 SPACE (2) CB120 CB250 SPACE (3) CB /240 S 9PT N LC33N /240 S 9PT N LC55N Model Number is also suitable for use as Temporary Site + Also Available in Ring Type - Replace R with M. Service Equipment when installed in accordance with the N.E.C. 1 Not UL Listed * Wire Range Table on page 34 or 93

8 Power Outlets Technical Data REPLACEMENT PARTS CABINET DIMENSIONS MODEL CABINET ENCLOSURE KNOCKOUT NUMBER METER POST STYLE HEIGHT WIDTH DEPTH FIGURE SOCKET LUGS SIZE page 68 A B C page 68 M058C MSM X 30 B 30" 9-3/4" 5-3/16" 2 M058CB6 MSM100P9 LT100B350 9PT See page 69 M067CR2 MSM X 38 B 38-3/8" 14-3/4" 6-3/8" 5 M132CB6 MSM100P9 LT100B350 9PT See page 69 M132CP6 MSM100P9 LT100S250 9PT See page 69 M354C MSM X 30 B 30" 9-3/4" 5-3/16" 2 M354CB6 MSM100P9 LT100B350 9PT See page 69 M354CP6 MSM100P9 LT100S250 9PT See page 69 M358CP6 MSM100P9 LT100S250 9PT See page 69 R058C MSR X 30 B 30" 9-3/4" 5-3/16" 2 R058CB6 MSR100P9 LT100B350 9PT See page 69 R058CP6 MSR100P9 LT100S250 9PT See page 69 U002C 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U004F 14 X 21 A 21-3/8" 14-3/4" 6-7/16" 3 U010 5 X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U010C 6 X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U010F 5 X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U010H 5 X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U011 6 X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U011F 6 X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U013 5 X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U013C 6 X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U013F 5 X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U014C X 21 A 21-3/8" 14-3/4" 6-7/16" 3 U023 5 X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U041 6 X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U041C 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U041F 6 X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U050 5 X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U050C 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U051F 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U054 5 X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U054F 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U055F 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U058C 9 X 17 A 17-3/8" 9-1/4" 5-3/16" 2 U058CB6 LT100B250 9PT See page 69 U058CP6 LT100S250 9PT See page 69 U061C 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U061CB6 LT200B250 6PT See page 69 U061CP6 LT100S250 6PT See page 69 U061CTL 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U070C 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U075C 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 Temp Power / Power Outlets 67

9 Power Outlets 3 Power Outlets Technical Data REPLACEMENT PARTS CABINET DIMENSIONS MODEL CABINET ENCLOSURE KNOCKOUT NUMBER METER POST STYLE HEIGHT WIDTH DEPTH FIGURE SOCKET LUGS SIZE page 68 A B C page 68 U132CB6 LT100B250 6PT U132CP6 LT100S250 6PT See page 69 See page 69 U132CTL 9 X 17 A 17-3/8" 9-1/4" 5-3/16" 2 U154F 14 X 21 A 21-3/8" 14-1/4" 6-7/16" 3 U354C 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U361G 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U501 5 X 7 A 7-1/8" 5-3/4" 5-3/16" 4 U511C 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U511G 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U546 6 X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U550F 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U614C 14 X 21 A 21-3/8" 14-3/4" 6-7/16" 3 U870G 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 Cabinet Dimensions (FIG. A) (FIG. B) Knockout Configurations (FIG. 1) (FIG. 2) (FIG. 3) (FIG. 4) (FIG. 5) A= 1-1/2", 2", 2-1/2" F= 1/2", 3/4" B= 1", 1-1/4", 1-1/2" G= 1/2", 3/4", 1" C= 1-1/4", 1-1/2", 2" H= 1/2", 3/4", 1", 1-1/4" D= 3/4", 1", 1-1/4" N= 1/2", 3/4", 1", 1-1/4", 1-1/2" E= 3/4" Q= 1" 68

10 Power Outlets Post Dimensions 6PT EARTH BURIAL UNMETERED A 62" C 19-3/4" D 6-1/2" E 3-1/4" F 18" G 6" 6PT PAD MOUNT UNMETERED A 36" C 17-3/4" D 6-1/2" E 3-3/4" Single Head Post Double Head Post (Back to Back) Single Head Post Double Head Post (Back to Back) Temp Power / Power Outlets 9PT EARTH BURIAL 9PT PAD MOUNT UNMETERED METERED A 64-1/2" 77-1/2" B /4" C 19-1/8" 19-1/8" D 9" 9" E 3-1/4"* 3-1/4"* F 18" 18" G 6" 6" UNMETERED METERED A 41-1/8" 53-1/2" B /2" C 19-3/4" 19-1/2" D 9" 9" E 3-1/4"* 3-1/4"* * Some models available in 4-3/8". Contact Distributor/Factory. Single Head Post Double Head Post (Back to Back) * Some models available in 4-3/8". Contact Distributor/Factory. Single Head Post Double Head Post (Back to Back) 14PT EARTH BURIAL UNMETERED METERED A 86" 86" B " C 49-1/2" 49-1/2" D 9" 9" E 4-3/8" 4-3/8" F 18" 18" G 6" 6" KEY A = B = C = D = E = F = G = Post Length Meter Center to Grade Terminal Bar to Grade Post Width Post Depth Grade to Wire Opening Wire Opening Single Head Post Double Head Post (Back to Back) 69

11 Power Outlets 3 Power Outlets Wire Range Tables TABLE A Connector Copper Aluminum Solid Strand Solid Strand Line Load Neutral Equip. Grnd TABLE E Connector Connector Copper Aluminum Solid Strand Solid Strand Line / /0 Load End Neutral Hole Side Neutral Hole Copper Aluminum Solid Strand Solid Strand Line Load Neutral Equip. Grnd TABLE G Connector TABLE P Copper Aluminum Solid Strand Solid Strand Line Load Neutral Equip. Grnd TABLE M Connector Copper Aluminum Solid Strand Solid Strand Line Load Neutral Equip. Grnd Line Neutral Equip. Grnd TABLE B Copper Aluminum Connector Solid Strand Solid Strand Line Load Neutral Equip. Grnd TABLE F Copper Aluminum Connector Solid Strand Solid Strand Line Load Neutral Equip. Grnd TABLE K Copper Aluminum Connector Solid Strand Solid Strand Line Load Neutral End Hole Side Neutral Hole Equip. Grnd TABLE O Copper Aluminum Connector Solid Strand Solid Strand Line Load Neutral End Hole Side Neutral Hole Equip. Grnd TABLE U Copper Aluminum Connector Solid Strand Solid Strand Line / /0 Load Neutral Large Hole / /0 Small Neutral Hole Equip. Grnd

12 Notes 71

13 Recreational Vehicle 72

14 Recreational Vehicle Park Equipment Application Information Today, most recreational vehicle parks provide power for their tenants. This application presents unique requirements including user safety, rugged construction, weather protection, receptacle versatility and attractiveness. The 2002 National Electric Code Requires: Type Receptacles Provided. Every recreational vehicle site with electrical supply shall be equipped with at least one 20-ampere, 125-volt receptacle. A minimum of 5 percent of all recreational vehicle sites with electrical supply, shall each be equipped with a 50-ampere, 125/250 volt receptacle conforming to the configuration as identified in Figure (c). These electrical supplies shall be permitted to include additional receptacles that have configurations in accordance with Section A minimum of 70 percent of all recreational vehicle sites with electrical supply shall each be equipped with a 30-ampere, 125-volt receptacle conforming to Figure (c). This supply shall be permitted to include additional receptacle configurations conforming to Section The remainder of all recreational vehicle sites with electrical supply shall be equipped with one or more of the receptacle configurations conforming to Section Dedicated tent sites with a 15- or 20-ampere electrical supply shall be permitted to be excluded when determining the percentage of recreational vehicle sites with 30- or 50-ampere receptacles. Additional receptacles shall be permitted for the connection of electrical equipment outside the recreational vehicle within the recreational vehicle park. All 125-volt, single-phase, 15- and 20-ampere receptacles shall have listed ground-fault circuit-interrupter protection for personnel. Transformer Transformer U075CTL (b). Disconnecting Means. A disconnecting switch or circuit breaker shall be provided in the site supply equipment for disconnecting the power supply to the recreational vehicle. Recreational Vehicle Parks are typically wired using either a loop-feed or radial-feed system as illustrated here. RV Products The most popular, and generally most economical, is the loop-feed system where each feeder services a single power outlet. Loop-Feed System Figure (c). Configurations for grounding-type receptacles and attachment plug caps used for recreational vehicle supply cords and recreational vehicle lots. RV Equipment Features and Benefits Radial-Feed System Rugged Durability All-In-One construction for factory assured terminations Rolled edge door for cord protection Heavy (16 gauge) galvanized zinc-coated steel with highest quality electro-deposition finish resists corrosion and fading Welded flange NEMA 3R construction for lasting service in outdoor installations User Safety Listed by Underwriters Laboratories, a safety plus Padlock provision can prevent unauthorized entry Dead front construction prevents accidental contact with live parts Installation Ease All components are factory wired and assembled, reducing installation time Midwest Electric offers a complete line of power outlets for recreational vehicle park application that meet the National Electrical Code: standard power outlets, post mounted power outlets (completely factory assembled and wired with loop-feed lugs in the post) and metered power outlets (ring-type and ringless). Also listed are surface mounted models with twin lugs per phase ideal for overhead loop-feed systems. Midwest offers both the traditional metallic equipment and the Parkmate series of non-metallic thermoplastic units. Midwest has the unit for your unique application. Power outlet door has stay-open position for user convenience All terminals accept copper or aluminum wire for added installation flexibility Wide range of receptacle configurations Broad range of concentric knock-outs to accommodate wiring needs All units with 12-2 Cu/Al equipment ground lug Posts Recreational vehicle park equipment available factory assembled on a padmount or earth-burial post for underground services. Factory wired from loop-feed lugs located in the post to receptacles reducing installation time Loop-feed lugs have twin MCM terminals per phase Cu/Al Rolled edge post bottoms to protect service cable Post door removable for installation ease 73

15 Recreational Vehicle Park Equipment Surface 5-20R2GFI 5-20R2 (2) 5-20R2GFI (2) 5-20R2GFI (2) 5-20R2 B U010C010 C U010G D U011C010 E U011CTL010 F U011G Products 4 (2) 5-20R2 R32U 5-20R2 BR32U 5-20R2 R32U 5-20R2GFI BR32U 5-20R2GFI G U011GTL H U040G I U040GTL J U041C010 K U041CTL010 Surface - Unmetered FIG. UL LUG TYPE MODEL NUMBER RECEPTACLES CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. AMP VOLTS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. B Y STANDARD U010C R2GFI CB B 6 X 9 Y 7 4 C Y STANDARD U010G 5-20R2 GFI B 6 X 9 Y 7 4 D Y STANDARD U011C010 (2) 5-20R2GFI (2) CB /240 P 6 X 14 Y LC33N7 10 E Y LOOP FEED U011CTL010 (2) 5-20R2GFI (2) CB /140 W 9 X 17 Y LC33N1T 14 1 SPACECB120 F Y STANDARD U011G (2) 5-20R2 G Y LOOP FEED U011GTL (2) 5-20R2 H Y STANDARD U040G I Y LOOP FEED U040GTL J Y STANDARD U041C010 K Y LOOP FEED U041CTL010 * Wire Range Table on page 93 R32U 5-20R2 BR32U 5-20R2 R32U 5-20R2GFI BR32U 5-20R2GFI (2) GFI120 (2) GFI /240 P 6 X 14 Y LC33N /240 W 9 X 17 Y LC33N1T 14 GFI130 GFI /240 P 6 X 14 Y LC33N GFI130 GFI /240 W 9 X 17 Y LC33N1T 14 1 CB130 CB /240 P 6 x 14 Y LC33N CB130 CB /240 W 9 x 17 Y LC33N1T

16 Recreational Vehicle Park Equipment Surface R32U 5-20R2 BR32U 5-20R R 5-20R2GFI 14-50R 5-20R2 A U041G B U041GTL C U055C010 D U055G RV Products 14-50R BR32U 5-20R2GFI E U075CTL R BR32U 5-20R2 F U075GTL 14-50R (2) 5-20R2GFI G U076C010 Surface - Unmetered FIG. UL LUG TYPE MODEL NUMBER RECEPTACLES A Y STANDARD U041G B Y LOOP FEED U041GTL C Y STANDARD U055C010 D Y STANDARD U055G R32U 5-20R2 BR32U 5-20R R CB R2GFI CB R CB R2 GFI120 CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. AMP VOLTS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. CB130 GFI /240 P 6 x 14 Y LC33N CB130 GFI /240 W 9 x 17 Y LC33N1T /240 P 6 X 14 Y LC33N /240 P 6 X 14 Y LC33N R CB250, CB130 E Y LOOP FEED U075CTL010 BR32U 5-20R2GFI CB /240 W 9 x 17 Y LC55N1T 16 1 F Y LOOP FEED U075GTL 14-50R BR32U CB250, CB130 GFI /240 W 9 x 17 Y LC55N1T R2 G Y STANDARD U076C010 * Wire Range Table on page R (2) 5-20R2GFI CB250 (2) CB /240 U 9 x 17 Y LC55N

17 Recreational Vehicle Park Equipment Surface 5-20R2GFI (2) BR32U 5-20R2GFI 14-50R 5-20R2GFI 14-50R 5-20R2 BR32U (2) 5-20R2 A U131CTL010 B U355C010 C U355G D U412G Products 4 (2) BR32U 5-20R2GFI (2) BR32U 5-20R2 E U611CTL010 F U611GTL BR32U 14-50R 14-50R 5-20R2GFI G U775C010 Surface - Unmetered FIG. UL LUG TYPE MODEL NUMBER RECEPTACLES A Y LOOP FEED U131CTL010 B Y STANDARD U355C010 C Y STANDARD U355G D Y STANDARD U412G E Y LOOP FEED U611CTL010 F Y LOOP FEED U611GTL (2) 5-20R2GFI (2) BR32U 14-50R 5-20R2GFI 14-50R 5-20R2 BR32U CB130 (2) 5-20R2 (2) GFI120 (2) BR32U (2) CB R2GFI CB120 (2) BR32U (2) CB R2 GFI120 CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. AMP VOLTS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. (2) CB120 (2) CB /240 U 14 X 21 Y LC55N1T 28 1 CB250 CB /240 U 9 X 17 Y LC55N CB250 GFI120 SPACE CB /240 U 9 X 17 Y LC55N /240 U 9 X 17 Y LC33N /240 W 9 X 17 Y LC33N1T /240 W 9 X 17 Y LC33N1T 15 1 (2) 14-50R (2) CB250T G Y STANDARD U775C010 BR32U 5-20R2GFI CB130 CB120T /240 W 9 X 17 Y 15 1 * Wire Range Table on page 93 76

18 Recreational Vehicle Park Equipment Surface 5-20R2GFI (2) 14-50R A M004C010 (2) 5-20R2GFI (2) 5-20R2 B C M011C010 M011G R011C010 R011G BR32U 5-20R2GFI D M041C010 BR32U 5-20R2 E M041G R041G 14-50R 5-20R2GFI F M055C010 R055C010 RV Products 14-50R 5-20R R BR32U 5-20R2GFI 14-50R BR32U 5-20R2 G M055G R055G H M075C010 I M075G 14-50R (2) 5-20R2GFI J M076C010 R076C R 5-20R2GFI 14-50R 5-20R2 K M355C010 L M355G R355G Surface - Metered MODEL NUMBER CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. FIG. UL RECEPTACLES AMP VOLTS RING TYPE RINGLESS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. A Y M004C R2GFI (2) CB250 (2) 14-50R CB /240 AA 9 X 30 Y LC55N B Y M011C010 R011C010 (2) 5-20R2GFI C Y M011G R011G (2) 5-20R2 D Y M041C010 E Y M041G R041G F Y M055C010 R055C010 G Y M055G R055G BR32U 5-20R2GFI BR32U 5-20R2 (2) CB120 (2) GFI R CB R2GFI CB R CB R2 GFI /240 AA 9 X 30 Y LC33N /240 AA 9 X 17 Y LC33N CB130 CB /240 AA 9 X 30 Y LC33N CB130 GFI /240 AA 9 X 30 Y LC33N /240 AA 9 X 30 Y LC33N /240 AA 9 X 30 Y LC33N R CB250, CB130 H Y M075C010 BR32U CB /240 AA 9 X 30 Y LC55N R2GFI 14-50R CB250, CB130 I Y M075G BR32U 5-20R2 GFI /240 AA 9 X 30 Y LC55N J Y M076C010 R076C010 K Y M355C010 L Y M355G R355G * Wire Range Table on page R (2) 5-20R2GFI CB250 (2) CB /240 AA 9 X 30 Y LC55N R CB250, CB R2GFI (2) /240 AA 9 X 30 Y LC55N R 5-20R2 CB250 GFI /240 AA 9 X 30 Y LC55N (2) SPACE CB

19 Recreational Vehicle Park Equipment Surface BR32U 5-20R2GFI 14-50R 5-20R2GFI 14-50R BR32U 5-20R2GFI 14-50R 5-20R2GFI A M041C010U B M055C010U C M075C010U D M355C010U Products 4 Surface - Metered Bottom Feed MODEL NUMBER CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. FIG. UL RECEPTACLES AMP VOLTS RING TYPE RINGLESS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. A Y M041C010U BR32U CB130, CB R2GFI B Y M055C010U R055C010U 14-50R CB R2GFI CB / x 30U Y LC33N /240 AA 9 x 30U Y LC33N R CB250, CB130 C Y M075C010U** BR32U CB / X 30U Y LC55N R2GFI D Y M355C010U 14-50R CB250, CB R2GFI (2) / X 30U Y LC55N * Wire Range Table on page 93 ** Florida Metering Group (FMG) approved model available. Order as model M075C010UFMG ; Consult Manufacturer 78

20 Recreational Vehicle Park Equipment Pedestal (2) 14-50R (1) 5-20R2GFI A U004CP6010 (2) 5-20R2GFI (2) 5-20R2 R32U 5-20R2 R32U 5-20R2GFI R32U 5-20R2 B U011CP6010 C U011GP6 D U040GP6 E U041CP6010 F U041GP6 RV Products R32U 5-20R R 5-20R2GFI 14-50R BR32U 5-20R2GFI 14-50R BR32U 5-20R2GFI 14-50R BR32U 5-20R2 (2) BR32U (2) 5-20R2GFI G U042GP6 Pedestal - Unmetered H U055CP6010 FIG. UL MODEL NUMBER RECEPTACLES A Y U004CP6010 B Y U011CP6010 (2) 5-20R2GFI C Y U011GP6? (2) 5-20R2? D Y U040GP6 R32U 5-20R2 E Y U041CP6010 R32U?, % 5-20R2GFI I U075CP6010 (2) 14-50R (2) CB R2GFI CB120 For Pad Mount Model Replace CP6 with CP4 or GP6 with GP4 * Wire Range Table on page 93 p Post depth dimension is non-standard (4-3/8"). & Also available with GFI 20A breaker order as U043GP6 J U075CP6010D K U075GP6 L U131CP6010 CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION A M P VOLTS RANGE * SIZE OPENING NEUTRAL BAR WT. PKG. (2) CB120 (2) GFI /240 T2 9PT N LC55N /240 T2 6PT N LC33N /240 T2 6PT N LC33N GFI130 GFI /240 T2 6PT N LC33N CB130 CB /240 T2 6PT N LC33N CB130 F Y U041GP6 R32U? 5-20R2 GFI /240 T2 6PT N LC33N G Y U042GP6 R32U GFI130 MAIN & 5-20R2 CB130, CB120 H Y U055CP R 5-20R2GFI T2 6PT N LC33N CB250, CB /240 T2 6PT N LC33N I Y U075CP R BR32U CB250, CB130 CB /240 T2 9PT N LC55N R2GFI 14-50R CB250, CB130 J Y U075CP6010D P BR32U CB /240 T2 9PT N LC55N R2GFI 14-50R CB250, CB130 K Y U075GP6? BR32U 5-20R2 GFI /240 T2 9PT N LC55N L Y U131CP6010 (2) BR32U (2) CB130, (2) CB /240 T2 9PT N LC55N (2) 5-20R2GFI % Also available with added factory-installed TV/Telephone. Replace 010 with 031. U075CP6031 has a Wire Range S, see page

21 Recreational Vehicle Park Equipment Pedestal 14-50R 5-20R2 BR32U (2) 5-20R2GFI BR32U (2) 5-20R2 (2) BR32U 5-20R2GFI BR32U 14-50R 14-50R 5-20R2GFI A U355GP6 B U412CP6010 C U412GP6 D U611CP6010 E U775CP6010 Products 4 Pedestal - Unmetered FIG. UL MODEL NUMBER RECEPTACLES A Y U355GP6 B Y U412CP6010 C Y U412GP R CB250, GFI R2 (2) BR32U CB130 (2) 5-20R2GFI (2) CB120 BR32U CB130 (2) 5-20R2 (2) GFI120 CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. AMP VOLTS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG /240 T2 9PT N LC55N /240 T2 9PT N LC33N /240 T2 9PT N LC33N D Y U611CP R2GFI (2) BR32U (2) CB120 CB /240 T2 9PT N LC33N (2) 14-50R (2) CB250T E Y U775CP BR32U CB /240 T2 9PT N R2GFI CB120T * Wire Range Table on page 93 1 Pad Mount Model U611CP Pad Mount Model U775CP4010 PLK50 Replacement deadfront kit with 50 Amp lockout feature for all U075- or M075-series units. Consult Manufacturer for details. 80

22 Recreational Vehicle Park Equipment Pedestal 5-20R2GFI (2) 14-50R A U004CB6010 (2) 5-20R2 5-20R2GFI R32U B U011GB6 C U041CB R2 R32U D U041GB6 5-20R2 R32U E U042GB6 5-20R R F U055GB6 5-20R2GFI BR32U 14-50R G U075CB R2 BR32U 14-50R H U075GB6 5-20R2GFI (2) BR32U I U611CB6010 RV Products Pedestal - Unmetered, Back to Back FIG. UL MODEL NUMBER A Y U004CB6010 RECEPTACLES (PER SIDE) B Y U011GB6 4 (2) 5-20R2 C Y U041CB6010 (2) 14-50R (2) CB R2GFI CB120 R32U 5-20R2GFI D Y U041GB6 1 R32U 5-20R2 E Y U042GB6 F Y U055GB6 CIRCUIT PROTECTION AMP VOLTS (PER SIDE) (2) GFI120 R32U GFI130 MAIN 5-20R2 (2) CB R CB R2 GFI120 WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG /240 S 9PT N LC55N /240 T2 6PT N LC33N CB130 CB /240 T2 6PT N LC33N CB130 GFI /240 T2 6PT N T2 6PT N LC33N /240 T2 6PT N LC33N R CB250, CB130 G Y U075CB6010 2, % BR32U CB /240 S 9PT N LC55N R2GFI 14-50R CB250, CB130 H Y U075GB6 BR32U 5-20R2 GFI /240 S 9PT N LC55N I Y U611CB R2GFI (2) BR32U (2) CB120 CB /240 T2 9PT N LC33N Pad Mount Model U041GB4 2 Pad Mount Model U075CB Pad Mount Model U611CB Pad Mount Model U011GB4 % Also available with added factory-installed TV/Telephone. Replace 010 with 031. * Wire Range Table on page 93 81

23 Recreational Vehicle Park Equipment Pedestal (2) 14-50R (1) 5-20R2GFI BR32U 5-20R2GFI BR32U 5-20R2 A M004CP6010 B M041CP6010 R041CP6010 C M041GP6 R041GP R 5-20R R BR32U 5-20R2GFI D M055GP6 E M075CP6010 R075CP6010 Products R BR32U 5-20R R 5-20R2GFI 14-50R 5-20R2 5-20R R F M075GP6 R075GP6 G M355CP6010 H M355GP6 R355GP6 I M655GP6 BR32U 14-50R 14-50R 5-20R2GFI J M775CP6010 Pedestal - Metered MODEL NUMBER CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. FIG. UL RECEPTACLES AMP VOLTS RING TYPE RINGLESS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. 82 A Y M004CP6010 B Y M041CP R041CP6010 C Y M041GP6 5 R041GP6 D Y M055GP6 (2) 14-50R (2) CB R2GFI CB120 BR32U 5-20R2GFI BR32U 5-20R R CB R2 GFI /240 T2 9PT N LC88X CB130 CB /240 T2 9PT N LC33N CB130 GFI /240 T2 9PT N LC33N /240 T2 9PT N LC33N R CB250, CB130 E Y M075CP6010 1,**,% R075CP6010 % BR32U 5-20R2GFI CB /240 T2 9PT N LC55N F Y M075GP6 2 R075GP R BR32U CB250, CB130 GFI /240 T2 9PT N LC55N R2 G Y M355CP6010 R355CP6010 % 14-50R 5-20R2GFI H Y M355GP6 3 R355GP6 I Y M655GP R 5-20R2 CB250 CB120 (2) SPACE /240 T2 9PT Y LC55N CB250 GFI120 SPACE CB /240 T2 9PT N LC55N CB250, GFI R SPACE CB2200B 5-20R2 SPACE (5) CB A. MAX /240 T2 14PT N LC1212PC 89 1 J Y M775CP6010 (2) 14-50R BR32U (2) CB250T CB /240 T2 9PT N R2GFI CB120T 1 Pad Mount Model M075CP Pad Mount Model M041CP Pad Mount Model M075GP4 5 Pad Mount Model M041GP4 3 Pad Mount Model M355GP4 % Also available with added factory-installed TV/Telephone in post. Replace 010 with 031. Also available withpenta-head kit installed, 9" or 14" post. Order as M355GP6028. Consult Manufacturer. * Wire Range Table on page 93 ** If Florida Metering Group (FMG) needed, specify FMG when ordering. Consult Manufacturer.

24 Recreational Vehicle Park Equipment Pedestal BR32U 5-20R2GFI A M041CB6010 BR32U 5-20R R BR32U 5-20R2GFI B M041GB6 C M075CB6010 R041GB R BR32U 5-20R2 D M075GB6 R075GB6 RV Products 14-50R 5-20R2 E M355GB R 5-20R2 F M655GB6 BR32U 14-50R 14-50R 5-20R2GFI G M775CB6010 Pedestal - Metered, Back to Back FIG. UL RING TYPE MODEL NUMBER RINGLESS A Y M041CB6010 B Y M041GB6 R041GB6 RECEPTACLES (PER SIDE) BR32U 5-20R2GFI CIRCUIT PROTECTION AMP VOLTS (PER SIDE) CB130, CB120 BR32U CB130, GFI R2 WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG /240 S 9PT N LC33N /240 S 9PT N LC33N C Y M075CB R075CB R BR32U CB250, CB130 CB /240 S 9PT N LC55N R2GFI 14-50R CB250, CB130 D Y M075GB6 R075GB6 BR32U GFI /240 S 9PT N LC55N R2 E Y M355GB6 F Y M655GB R 5-20R R 5-20R2 CB250 GFI120 (2) SPACE CB /240 S 9PT N LC55N CB250 GFI /240 S 14PT N (9) LC1212PC N1200A (2) 14-50R (2) CB250T G Y M775CB6010 BR32U CB /240 S 9PT N R2GFI CB120T 1 Pad Mount Model M075CB4010 * Wire Range Table on page 93 83

25 Recreational Vehicle Park Equipment Lighted RV BR32U 5-20R2GFI A U041CTLL10 BR54U BR32U 5-20R2GFI B U075CTLL10 Products 4 Surface - Unmetered FIG. UL LUG TYPE MODEL NUMBER RECEPTACLES A Y LOOP FEED U041CTLL10 BR32U 5-20R2GFI CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. PROTECTION AMP VOLTS RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. CB130 CB /240 W 9 X 17 N LC33N1T 14 1 BR54U CB250, CB130 B Y LOOP FEED U075CTLL10 BR32U 5-20R2GFI CB120 SPACE /240 W 9 x 17 N LC55N1T 16 1 * Wire Range Table on page 93 BR32U 5-20R2GFI SPACE 14-50R BR32U 5-20R2GFI 14-50R BR32U 5-20R2GFI C M041CP6L10 D M075CB6L10 E M075CP6L10 Pedestal - Metered FIG. UL MODEL NUMBER CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. RECEPTACLES AMP VOLTS RING TYPE RINGLESS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. BR32U CB130 C Y M041CP6L R2GFI SPACE CB120 SPACE /240 T2 9PT Y LC33N Pad Mount Model M041CP4L10 2 Pad Mount Model M075CB4L10 3 Pad Mount Model M075CP4L10 % Also available with added factory-installed TV/Telephone. Replace 010 with 031. * D Y M075CB6L10 2,% 14-50R BR32U CB250, CB130 CB /240 T2 9PT Y LC55N R2GFI 14-50R CB250, CB130 E Y M075CP6L10 3,% BR32U CB /240 T2 9PT Y LC55N R2GFI Wire Range Table on page 93 = Lighted Lamp Assembly 84

26 Recreational Vehicle Park Equipment Lighted RV R32U 5-20R2GFI A U041CB6L10 R32U 5-20R2GFI R32U 5-20R2 BR54U BR32U 5-20R2GFI BR54U BR32U 5-20R2GFI BR54U BR32U 5-20R2 B U041CP6L10 C U041GP6L D U075CB6L10 E U075CP6L10 F U075GP6L Pedestal - Unmetered FIG. UL MODEL NUMBER RECEPTACLES CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. AMP VOLTS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. A Y U041CB6L10 1 R32U CB130, CB /240 T2 6PT N LC33N R2GFI B Y U041CP6L10 2 R32U CB130, CB /240 T2 6PT N LC33N R2GFI R32U CB130 C Y U041GP6L R2 CB /240 T2 6PT N LC33N BR54U CB250, CB130 D Y U075CB6L10 4 BR32U 5-20R2GFI GFI /240 S 9PT N LC55N E Y U075CP6L10 5 BR54U BR32U CB250, CB130 GFI /240 T2 9PT N LC55N R2GFI BR54U CB250, CB130 F Y U075GP6L 6 BR32U GFI /240 T2 9PT N LC55N R2 RV Products 1 Pad Mount Model U041CB4L10 2 Pad Mount Model U041CP4L10 3 Pad Mount Model U041GP4L 4 Pad Mount Model U075CB4L10 5 Pad Mount Model U075CP4L10 6 Pad Mount Model U075GP4L * Wire Range Table on page 93 = Lighted Lamp Assembly Camper Clips CLP1 Spring tensioned clips used to attach site cards to post. Kit contains six clips and six screws. 85

27 Recreational Vehicle Park Equipment R.V. POWER CENTER Parkmate RV Power Centers represent the latest in technology and design, combining appearance and functionality. Now, campground owners can select an attractive power center that combines all the features RVers request. Parkmate is excellent for surface mount and post applications, offering a wide array of accessories including: light, photoelectric sensor, telephone, cable T.V. connections and electric metering. All this in one attractive package - now that makes sense! Parkmate is injection molded from VALOX engineered thermoplastic resin. VALOX resin is a lightweight, impact and corrosion resistant material, designed to provide long, maintenance free service. Parkmate RV Power Centers are rugged, convenient and attractive. Manufactured in the quality tradition of Midwest Electric Products, Inc. VKKJHCQT Products 4 F L U O R E S C E N T L I G H T L o n g l a s t i n g, l o w c o n s u m p t i o n 7 w a t t l i g h t p r o v i d e s s e c u r i t y a n d e a s y night time plug in. E L E C T R O N I C D I G I T A L M E T E R C A B L E T V J A C K T E L E P H O N E J A C K S I N G L E O R B A C K T O B A C K M O D E L S 86 G - 9 0, H E A V I L Y G A L V A N I Z E D S T E E L P O S T W A T E R S H R O U D A C C E S S O R Y (f a u c e t n o t i n c l u d e d ) M O L D E D O F T O U G H V A L O X T H E R M O P L A S T I C U P T O T H R E E R E C E P T A C L E S A V A I L A B L E P H O T O C E L L ( Not Shown) 20 AMP AVAILABLE w i t h G F I b r e a k e r o r G F I r e c e p t a c l e s. L O O P F E E D L U G S K C M I L S T A N D A R D F A C T O R Y W I R E D F O R E A S Y I N S T A L L A T I O N D I R E C T B U R I A L O R P A D M O U N T I N S T A L L A T I O N Features and Benefits Service Entrance rated and Listed by Underwriters Laboratories VALOX thermoplastic enclosure and internal components are corrosion resistant Factory wired power receptacles are available in 20 amp, 30 amp, or 50 amp configurations protected by thermal magnetic circuit breakers. Ground Fault breakers are also available Hinged cover closes over plugs and cords, maintaining a safe, weather tight enclosure Easy to wire terminal lugs accept up to 1/0 Cu/Al cable Post features 350 KCMIL loop-feed lugs Optional 7 watt fluorescent light illuminates receptacle for easy night time plug-in, while providing security lighting and easy identification of power center location. Light circuit is protected by a 20 Amp circuit breaker. Light cover molded of LEXAN polycarbonate Photoelectric sensor automatically turns light on and off Telephone and cable TV jack accessory kits mount easily in power center, giving your installation a neat and uncluttered appearance. Telephone jacks are PH6596 corrosion resistant outlets. Cable TV jacks are suitable for type RG-59 coax cable Electrical rating of 100 amp max., 120/240 volt, 1Ø-3 wire with ground Hinged cover has a positive latch with padlocking provisions Post dimensions are 62"H (38" above grade) x 9"W x 3-1/4"D or 4.394"D Optional loop feed lug kit (ULOOP) available for Parkmate not on a post Parkmate, post, and water shroud are tan in color Standard 200A/350KCMIL lugs installed in Pedestal models. Amp Rating 200 Amp on back-to-back; 100 Amp on single. NOTE: Metered units for use in California require special testing and certification. Contact Manufacturer for information.

28 Recreational Vehicle Park Equipment ORDERING INFORMATION Example: Model Number VPKJHCQT VP KJH CQ T MODEL SIDE 1 SIDE 1 SIDE 2 SIDE 2 PAINT TYPE* RECEPTACLE* OPTIONS* RECEPTACLE* OPTIONS* OPTIONS (WHERE APPLICABLE) (WHERE APPLICABLE) MODEL TYPE RECEPTACLES OPTION CODES COLOR VK VL VM VN VO VP VQ VR VS VT NEMA CIRCUIT Code RECEPTACLES BREAKER AMPS VOLTS H 5-20R2 CB I 5-20R2GFI GFI J R32U CB K 14-50R CB /250 Z None None *Other configurations available. Contact Manufacturer. MOST COMMON MODEL NUMBERS + Metered w/ 7 watt light 7 watt light, Parkmate Receptacle No 7 watt light photo-cell & Metered photo-cell, Model Configuration Options 7 watt light & photo cell 1-TV/Phone Only 1-TV/Phone Choose specific 20A/20A ZHHAAT ZHHAQT ZHHAUT HHHCQT ZHHACT ZHHCST model 30A/20A JZHAAT JZHAQT JZHAUT JZHCQT JZHACT JZHCST 50A/20A KZHAAT KZHAQT KZHAUT KZHCQT KZHACT KZHCST 30A/30A/20A JJHAAT JJHAQT JJHAUT JJHCQT JJHACT JJHCST 50A/30/20A KJHAAT KJHAQT KJHAUT KJHCQT KJHACT KJHCST + To complete model number add Model Type followed by Option code desired. MODEL TYPE POST TYPE # HEADS V K Parkmate 1 V L Parkmate for Post (Replacement Head ONLY) 1 V M Parkmate, single head, stainless post, pad mount 1 V N Parkmate, single head, stainless post, burial 1 V O Parkmate, single head, galvanized post, pad mount 1 V P Parkmate, single head, galvanized post, burial 1 V Q Parkmate, back to back head, stainless post, pad mount 2 V R Parkmate, back to back head, stainless post, burial 2 V S Parkmate, back to back head, galvanized post, pad mount 2 V T Parkmate, back to back head, galvanized post, burial 2 PARKMATE OPTIONS/ACCESSORIES MODEL DESCRIPTION VLIGHT 7 WATT FLUORESCENT LIGHT VLOOP 1/0 LOOP LUG KIT VAMBER AMBER LENS COVER VAPE PHOTOELECTRIC SENSOR VKTELTV1 TELE/TV CONNECTION KIT (PARKMATE) * VKTELTV2 TELE/TV CONNECTION KIT (PARKMATE) * ULUG3 4th POSITION LUG FOR 3-PHASE LOOP FEED #6-350 KCMIL UH90ST STAINLESS WATER SHROUD (PARKMATE) UH90GT GALVANIZED WATER SHROUD (PARKMATE) UHH ONE PAIR CORD & HOSE STORAGE RACK UBFP BACKFLOW PREVENTER UWATER34 3/4" HOSE BIB VMASTER1S 125V ELECTRIC METER KIT-SINGLE VMASTER2S 125V ELECTRIC METER KIT-DUAL VMASTER1D 125/250V ELECTRIC METER KIT-SINGLE VMASTER2D 125/250V ELECTRIC METER KIT-DUAL * STANDARD RJ-11 PHONE JAC AA AU AW CP AC AS CM CS CO BY (See below) T = Standard Tan W = Optional White Note - No KOs provided for surface mounted units MOST COMMON OPTIONS** OPTION CODE AA AU AW CQ AC AS CM CS CO EK DESCRIPTION No Options 7W Light and Photocell 7W Light, Photocell and Metered 1 TV/Telephone, 7W light and Photocell Metered Only 7W Light and Metered 1 TV/Telephone, and 7W Light 1 TV/Telephone, 7W Light, Photocell and Metered 1 TV/Telephone, 7W Light and Metered 2 TV/Telephone, 7W Light and Metered ** Other configurations Available. Contact Manufacturer. 87 RV Products

29 Recreational Vehicle Park Equipment Temporary Adapters Offer increased flexibility to adapt to any power outlet configuration. AD CAMPER ADAPTER ADAPTS AD TRAVEL TRAILER ADAPTER ADAPTS TO TO 15 AMP., 125 VOLT 30 AMP., 125 VOLT 10 PK. ONLY 30 AMP., 125 VOLT 15 AMP., 125 VOLT 10 PK. ONLY Products 4 AD MOBILE HOME-MOTOR HOME ADAPTS TO Television/Telephone Add-On TTV100 Telephone and TV Add-on accessory bolts on to the back of a post or a wall. The open back and open bottom make for easy wiring. Factory or field-installed Telephone/TV receptacle may be field replaced with data (Cat5), phone or other similar feature receptacle. Unit is non-nema and non-ul. 50 AMP., 125/250 VOLT 20 AMP., 125 VOLT 10 PK. ONLY RV Retrofit Light Kit Lighted RV units add affordable security and accessibility with easy field installation affix site number to outside of acrylic lens for easy illumination of site number. Retrofit kits include a 2.8-watt LED lamp and socket, deadfront, and replacement cover complete with shatterproof, UV-resistant acrylic lens. 6RVLIGHT 9RVLIGHT Angle Plugs Light Kit for 6" Units Light Kit for 9" Units Electronic Meter Retrofit Kit Reliable electronic metering can be added to your existing Parkmate, Dockmate, or Dockmaster installation with this exclusive kit. DOCKMASTER VMASTER1S Single Meter PARKMATE and DOCKMATE MMATE1S Single Meter MMATE2S Dual Meter Offer increased flexibility to plug into receptacles at an angle where space limitations exist. Plugs are molded of Zytel Nylon, a rugged impact resistant material. NEMA CONFIGURATIONS AMP VOLTAGE MODEL NUMBER ANSI C R-32-U C32U 30 Amp. 125 Volt (Travel Trailer Use Only) 14-50R C54U 88 C32U C54U

30 Recreational Vehicle Park Equipment Technical Data REPLACEMENT PARTS CABINET DIMENSIONS MODEL CABINET ENCLOSURE KNOCKOUT NUMBER METER POST STYLE HEIGHT WIDTH DEPTH FIGURE SOCKET LUGS SIZE page 91 A B C page 91 M004C010 MSM X 30 B 30" 9-3/4" 5-3/16" 2 M004CP6010 MSM100P9 LT100S250 9PT M011C010 MSM100P9 9 X 30 B 30" 9-3/4" 5-3/16" 2 M011G MSM X 30 B 30" 9-3/4" 5-3/16" 2 M041C010 MSM X 30 B 30" 9-3/4" 5-3/16" 2 M041C010U MSM100EZ 9 X 30U C 30" 9-3/4" 5-3/16" M041CB6010 LT100B350 9PT M041CP4L10 MSM100P9 LT100S250 9PT M041CP6010 MSM100P9 LT100S250 9PT M041CP6L10 MSM100P9 LT100S250 9PT M041G MSM X 30 B 30" 9-3/4" 5-3/16" 2 M041GB6 LT100B350 9PT M041GP6 MSM100P9 LT100S250 9PT M055C010 MSM X 30 B 30" 9-3/4" 5-3/16" 2 M055G MSM X 30 B 30" 9-3/4" 5-3/16" 2 M055GP6 MSM100P9 LT100S250 9PT M075C010 MSM X 30 B 30" 9-3/4" 5-3/16" 2 M075C010U MSM100EZ 9 X 30U C 30" 9-3/4" 5-3/16" M075CB6010 LT100B350 9PT M075CP4010 MSM100P9 LT100S250 9PT M075CP4L10 MSM100P9 LT100S250 9PT M075CP6010 MSM100P9 LT100S250 9PT M075CP6L10 MSM100P9 LT100S300 9PT M075G MSM X 30 B 30" 9-3/4" 5-3/16" 2 M075GB6 LT100B350 9PT M075GP6 MSM100P9 LT100S250 9PT M076C010 MSM X 30 B 30" 9-3/4" 5-3/16" 2 M355C010 MSM X 30 B 30" 9-3/4" 5-3/16" 2 M355C010U MSM100EZ 9 X 30U C 30" 9-3/4" 5-3/16" M355G MSM X 30 B 30" 9-3/4" 5-3/16" 2 M355GB6 LT100B350 9PT M355GP6 MSM100P9 LT100S250 9PT M655GB6 MW200M LT100B350 14PT M655GP6 MW200M LT100S350 14PT R011C010 MSR X 30 B 30" 9-3/4" 5-3/16" 2 R011G MSR X 30 B 30" 9-3/4" 5-3/16" 2 R041G MSR X 30 B 30" 9-3/4" 5-3/16" 2 R041GB6 LT100B350 9PT R041GP6 MSR1009P LT100S250 9PT R055C010 MSR X 30 B 30" 9-3/4" 5-3/16" 2 R055G MSR X 30 B 30" 9-3/4" 5-3/16" 2 R075CP6010 MSR100P9 LT100S250 9PT RV Products Before 2/1/95: MS1S (Ring Type), MSR1S (Ringless) - Surface & Back to Back Units; MS1H (Ring Type), MSR1H (Ringless) - Front Post Units. Front (Inline Side) MSM100P9, Back (Powerhead side) MSM100HP Front (Inline Side) MSR100P9, Back (Powerhead side) MSR100HP 89

31 Products 4 Recreational Vehicle Park Equipment Technical Data 90 REPLACEMENT PARTS CABINET DIMENSIONS MODEL CABINET ENCLOSURE KNOCKOUT NUMBER METER POST STYLE HEIGHT WIDTH DEPTH FIGURE SOCKET LUGS SIZE page 91 A B C page 91 R075GB6 LT100B350 9PT R075GP6 MSR100P9 LT100S250 9PT R076C010 MSR X 30 B 30" 9-3/4" 5-3/16" 2 R355G MSR X 30 B 30" 9-3/4" 5-3/16" 2 R355GP6 MSR100P9 LT100S250 9PT U004CB6010 LT100B350 9PT U004CP6010 LT100S250 9PT U010C010 6 X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U010G 6 X 9 A 9-1/8" 7-1/4" 5-3/16" 1 U011C010 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U011CP6010 LT100S250 6PT U011CTL010 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U011G 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U011GB6 LT100B250 6PT U011GP6 LT100S250 6PT U011GTL 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U040G 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U040GP6 LT100S250 6PT U040GTL 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U041C010 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U041CB4L10 LT100B250 6PT U041CB6L10 LT100S250 6PT U041CP4L10 LT100S250 6PT U041CP6010 LT100S250 6PT U041CP6L10 LT100S300 6PT U041CTL010 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U041CTLL10 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U041G 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U041GB6 LT100B250 6PT U041GP4L LT100S250 6PT U041GP6 LT100S250 6PT U041GP6L LT100S250 6PT U041GTL 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U042GB6 LT100B250 6PT U042GP6 LT100S250 6PT U055C010 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U055CP6010 LT100S250 6PT U055G LC33N7 6 X 14 A 14-3/8" 7-1/4" 5-3/16" 1 U055GB6 LT100B250 6PT U075CB4L10 LT100B350 9PT U075CB6010 LT100B350 9PT U075CB6L10 LT100B350 9PT U075CP4L10 LT100S250 9PT U075CP6010 LT100S250 9PT U075CP6010D LT100S250 9PT U075CP6L10 LT100S300 9PT Front (Inline Side) MSR100P9, Back (Powerhead side) MSR100HP

32 Recreational Vehicle Park Equipment Technical Data REPLACEMENT PARTS CABINET DIMENSIONS MODEL CABINET ENCLOSURE KNOCKOUT NUMBER METER POST STYLE HEIGHT WIDTH DEPTH FIGURE SOCKET LUGS SIZE page 91 A B C page 91 U075CTL010 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U075CTLL10 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U075GB6 LT100B350 9PT U075GP4L LT100S250 9PT U075GP6 LT100S250 9PT U075GP6L LT100S250 9PT U075GTL 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U076C010 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U076G 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U131CP6010 LT100B250 14PT U131CTL X 21 A 21-3/8" 14-3/4" 6-7/16" 3 U355C010 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U355G 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U355GP6 LT100S250 9PT U412CP6010 LT100S250 9PT U412G 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U412GP6 LT100S250 9PT U611CB6010 LT100B250 9PT U611CP6010 LT100S250 9PT U611CTL010 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U611GTL 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 Cabinet Dimensions (FIG. A) (FIG. B) (FIG. C) RV Products Knockout Configurations (FIG. 1) (FIG. 2) (FIG. 3) (FIG. 4) A= 1-1/2", 2", 2-1/2" D= 3/4", 1", 1-1/4" N= 1/2", 3/4", 1", 1-1/4", 1-1/2" B= 1", 1-1/4", 1-1/2" E= 3/4" Q= 1" C= 1-1/4", 1-1/2", 2" G= 1/2", 3/4", 1" W= 1/2", 3/4", 1", 1-1/4", 2" 91

33 Recreational Vehicle Park Equipment Post Dimensions 6PT EARTH BURIAL UNMETERED A 62" C 19-3/4" D 6-1/2" E 3-1/4" F 18" G 6" 6PT PAD MOUNT UNMETERED A 36" C 17-3/4" D 6-1/2" E 3-3/4" Single Head Post Double Head Post (Back to Back) Single Head Post Double Head Post (Back to Back) 9PT EARTH BURIAL 9PT PAD MOUNT Products 4 UNMETERED METERED A 64-1/2" 77-1/2" B /4" C 19-1/8" 19-1/8" D 9" 9" E 3-1/2"* 3-1/2"* F 18" 18" G 6" 6" UNMETERED METERED A 41-1/8" 53-1/2" B /2" C 19-3/4" 19-1/2" D 9" 9" E 3-1/2"* 3-1/2"* * Some models available in 4-3/8". Contact Distributor/Factory. Single Head Post Double Head Post (Back to Back) * Some models available in 4-3/8". Contact Distributor/Factory. Single Head Post Double Head Post (Back to Back) 14PT EARTH BURIAL UNMETERED METERED A 86" 86" B " C 49-1/2" 49-1/2" D 9" 9" E 3-1/2"* 3-1/2"* F 18" 18" G 6" 6" KEY A = B = C = D = E = F = G = Post Length Meter Center to Grade Terminal Bar to Grade Post Width Post Depth Grade to Wire Opening Wire Opening * Some models available in 4-3/8". Contact Distributor/Factory. Single Head Post Double Head Post (Back to Back) 92

34 Recreational Vehicle Park Equipment Wire Range Tables TABLE B Copper Aluminum Connector Solid Strand Solid Strand Line Load Neutral Equip. Grnd TABLE P Copper Aluminum Connector Solid Strand Solid Strand Line / /0 Load End Hole Side Hole Neutral Neutral Equip. Grnd TABLE U Copper Aluminum Connector Solid Strand Solid Strand Line / /0 Load Large Hole Small Hole Neutral / /0 Neutral Equip. Grnd TABLE W Copper Aluminum Connector Solid Strand Solid Strand Line (Loop Feed) / /0 Load Large Hole Small Hole Neutral / /0 Neutral Equip. Grnd RV Products TABLE AA Copper Aluminum Connector Solid Strand Solid Strand Line / /0 Load Large Hole Small Hole Neutral / /0 Neutral Equip. Grnd TABLE AR Copper Aluminum Connector Solid Strand Solid Strand Line 14-1/0 14-1/ Load Neutral Equip. Grnd TABLE S Post Line Connectors Suitable for Loop Feed #6-350 KCMIL CU #6-350 KCMIL AL Equip. Grnd. #12-2 CU/AL TABLE T2 Post Line Connectors Suitable for Loop Feed #1-300 KCMIL CU #1-300 KCMIL AL Equip. Grnd. #12-2 CU/AL 93

35 Marina Products 94

36 Marina Products Application Information Today, most marinas and boat docks also provide shore power for their tenants. This application presents unique requirements including atmospheric conditions, receptacle versatility, rugged construction and attractiveness. The 1999 National Electrical Code requires: Receptacles. Receptacles that provide shore power for boats are required to be single and of the locking and grounding types Disconnecting Means. A readily accessible disconnecting means shall be provided by which each boat can be isolated from its circuit supply Branch Circuits. Each single receptacle that supplies shore power to boats shall be supplied from a power outlet or panelboard by an individual branch circuit of the voltage class and rating corresponding to the rating of the receptacle (a) Equipment to be Grounded. The following items shall be connected to an equipment-grounding conductor run with thecircuit conductors in a raceway or cable: 1) Boxes, cabinets and all other metal enclosures 2) Metal frames of utilization equipment 3) Grounding terminals of grounding-type receptacles Midwest Electric offers a complete line of metered and unmetered power outlets for marina applications. All Midwest marina power outlets utilize corrosion-resistant, grounding and locking type receptacles with individual circuit breaker protection enclosed in a single, easy to install enclosure. The different styles of construction in the products we manufacture include: - Non-metallic power centers-dockpro, Dockmaster and Dockmate - Metallic power centers- Dockhand, featuring galvanized steel construction REMOTE METERING PACKAGES AVAILABLE CONSULT MANUFACTURER Marina Products Not all products listed here. Contact your manufacturing representative for a full Marina Catalog. 95

37 Marina Products DOCKPRO Thermoplastic NEMA 3R enclosure with aluminum extrusion frame Power, phone & TV under same door 360 fluorescent or incandescent lighting for better visibility Electronic metering option Water shroud is included UL & CUL listed DOCKMASTER Injection molded GE thermoplastic Power, phone & TV under same door Energy saving fluorescent light Electronic metering option Water shroud option Crisp, clean appearance UL & CUL listed Products 5 DOCKMATE Power center for Dockbox, surface or pedestal Injection molded GE thermoplastic Electronic metering option Water shroud option Energy saving fluorescent light & photocell UL & CUL listed DOCKHAND Compact, durable and economical Painted galvanized steel Post or surface units Post available with loop feed lugs Metered or Unmetered UL & CUL listed NOTE: Metered units for use in California require special testing and certification. Contact Manufacturer for information. 96

38 Marina Products Accessories MARINA SUBSTATION Midwest Electric s marina substations provide a safe, economical way to deliver power to Power Centers and Power Pedestals. The substations consist of a core and coil dry-type transformer and a distribution panelboard in a common enclosure. NEMA 3R, Marine grade enclosures 15kva-300kva transformer range Contact Midwest rep for additional information HARBORLIGHT MARINA DOCKSIDE LIGHT FIXTURE Harborlight Features UL Listed Corrosion resistant VALOX housing, all stainless exterior hardware PL7 energy saving fluorescent lamps are included Separable non-metallic base for fast secure installation Prismatic lens made from tough, durable LEXAN Marina Products Ordering Information MODEL # DESCRIPTION VLITE071* 7 watt Fluorescent - Harborlight is suitable for 120V AC service - Light circuit should be provided by a circuit breaker or fuse (not included) * For newer style units ONLY. Units made before 2000 order DLIGHT071. Consult Manufacturer for correct model. VMASTER RETROFIT METER KITS FOR THE DOCKMASTER POWER CENTER Meter Features Meter module provides state of the art electronic digital metering Available in 120, 208, & 240V Factory assembled units are completely wired and ready for installation Not all products listed here. Contact your manufacturing representative for a full Marina Catalog. 97

39 Terminal Boxes 98

40 Terminal Boxes Application Information Terminal Boxes are for use in converting from overhead to underground services and for multi-circuit wiring. The NEMA 3R enclosure provides protection for all terminations inside and provides a convenient, time-saving means of wire splices and connections. Features and Benefits Save Costly Installation Time Terminals accept copper or aluminum wire Factory installed terminal bars Wide range of concentric knockouts Door has stay open position or removes completely Wide range of terminals meet varied application requirements Save Troubleshooting Time Stationary mounted terminations make circuit tracing much easier Midwest offers a full line of terminal boxes for 240 volt single phase and three phase, and three phase 600 volt ratings to meet your application requirements. Typical applications, both indoor and outdoor, include inter-building wiring on farms, convenient splicing means for industrial use and commercial construction. Offer Maximum Safety Padlock provisions to prevent unauthorized entry Ready To Work When You Are Completely factory assembled, take it out of the carton and it s ready to use Durable Long Lasting Construction Heavy zinc coated steel with electro-deposition paint finish Suitable for NEMA 3R and NEMA 1 installations UL Models listed as termination boxes 60 Amp 100 Amp 200 Amp 100 Amp 200 Amp 400 Amp 400 Amp A T1206 B T1210 C T1220 D T3210 T3610 E T3220 T3620 F T1240 G T /240 and 240 Volts AC FIG. UL MODEL NUMBER AMP VOLTAGE PHASE WIRE RANGE CABINET HUB UNIT STD. SIZE OPENING WT. PKG. A Y T /240 1 (4) X 9 Y 6 4 B Y T /240 1 (5) 14-1/0 9 X 17 Y 11 1 C Y T /240 1 (3) 1/0-250, (3) 12-1/0 14 X 21 Y 19 1 D Y T /240 3 (5) 14-1/0 9 X 17 Y 12 1 Terminal Boxes E Y T /240 3 (3) 1/0-250, (3) 12-1/0 14 X 21 Y 19 1 F N T (2) 1/0-600, (3) 1/ X 26 Y , 480Y / 277 and 600 Volts AC FIG. UL MODEL NUMBER AMP VOLTAGE PHASE WIRE RANGE CABINET HUB UNIT STD. SIZE OPENING WT. PKG. D Y T (5) 14-1/0 9 X 17 Y 12 4 E Y T (3) 1/0-250, (3) 12-1/0 14 X 21 Y 19 1 G N T (2) 1/0-600, (3) 1/ X 26 Y 29 1 Non-standard/Universal hub opening. Hub no longer furnished, order U30 hub separately. Consult Manufacturer. For Wire Range or Cabinet Tables see Application Data Section. 99

41 Terminal Boxes Technical Data REPLACEMENT PARTS MODEL NUMBER LUGS NUMBER TERMINAL OF PER BAR BARS BAR CABINET SIZE CABINET DIMENSIONS HEIGHT WIDTH DEPTH A B C KNOCKOUT FIGURE T1206 NI60B X 10 10" 7-1/4" 4" 1 T1210 NI100B X /2" 9-3/4" 3-1/2" 2 T1220 NI X /2" 14-1/2" 4-3/4" 3 T1240 NI400A X /4" 14-1/2" 4-3/4" 4 T3210 NI100B X /2" 9-3/4" 3-1/2" 2 T3220 NI X /2" 14-1/2" 4-3/4" 3 T3610 NI100B X /2" 9-3/4" 3-1/2" 2 T3620 NI200A X /2" 14-1/2" 4-3/4" 3 T3640 NI400A X /4" 14-1/2" 4-3/4" 4 Terminal Boxes Cabinet Dimensions Terminal Boxes Knockout Configurations Boxes 6 (FIG. 1) (FIG. 2) (FIG. 3) (FIG. 4) AA= 1-1/2", 2", 2-1/2" E= 3/4" B= 1", 1-1/4", 1-1/2" G= 1/2", 3/4", 1" C= 1-1/4", 1-1/2", 2" N= 1/2", 3/4", 1", 1-1/4", 1-1/2" D= 3/4", 1", 1-1/4" Q= 1" 100

42 Notes 101

43 Transfer Switches & Power Inlets 102

44 Transfer Switches Application Information The Midwest Heavy Duty manual transfer switch provides reliable, and trouble-free transfer of power from the normal utility supplied source to a stand-by generator enabling the user to maintain power during utility down time periods. The double throw mechanism helps prevent dangerous backfeeding of generator power into the utility system. The Midwest transfer switch is designed to be fully operational and switchable at full rated capacity. The Midwest Transfer switch is available in single phase and three phase configurations, and in ratings through 600v. Special application models with meter sockets or switched neutrals are also available. Typical applications include poultry farms and dairy farms, ventilation in animal confinement buildings, crop drying, and anywhere an extended loss of normal power service would result in severe loss, damage or inconvenience. Features and Benefits Electrical Ratings amperes 240 and 600 volt maximum models available 10,000 AIC Rugged Durability Quick-Make, Quick-Break switch mechanism on most models All-In-One Construction for factory assured terminations Bus bars used to interconnect main and standby switches on most models Knife blade switch contacts provide long life Heavy zinc coated steel with highest quality powder coat finish resists corrosion and fading Welded flange NEMA 3R construction for lasting service in outdoor installations Quality user tested components for long life Many models UL Listed Suitable for use as service equipment when installed in accordance with the NEC. GS1201B20UL User Safety Interlock allows door opening only when switch is in the off position on most models Padlock provision in all three on-off-on transfer positions Door has padlock provision Transfer Switches Installation Ease Optional neutral kit available for both 240 volt and 600-volt Broad range of concentric knockouts to accommodate varied wiring needs All terminals accept copper or aluminum wire for added installation flexibility U030N 103

45 Transfer Switches Single Phase Single Phase- Switched Neutral Three Phase Fig. A Fig. B Fig. C Single Phase 120/240 Volts AC FIG. UL MODEL NUMBER AMPS WIRE RANGE CABINET HUB* UNIT STD. VOLTS PHASE MAIN STANDBY (CuAl) SIZE (included) WGT. PKG. A Y GS1101B12UL / /0 2713G 1 1 /4" 32 1 NEU102 Order A Y GS3161G** / G Separately 11 1 INSTALLED A Y GS1201B20UL / G 2" 42 1 NEU202 A Y GS1202B20UL / G 2" 46 1 NEU202 A Y GS1402B01UL /240 1 A Y GS1404B01UL /240 1 ** Light Duty Transfer Switches or 4318G Order (2) 1/ NEU407 Separately or Order (2) 1/ G Separately Single Phase 120/240 Volts AC with Attached Meter Socket + FIG. UL MODEL NUMBER Single Phase 120/240 Volts AC - Switch Neutral FIG. UL MODEL NUMBER AMPS VOLTS PHASE WIRE RANGE CABINET HUB* UNIT STD. MAIN STANDBY (CuAl) SIZE (included) WGT. PKG. AMPS WIRE RANGE CABINET HUB* UNIT STD. VOLTS PHASE MAIN STANDBY (CuAl) SIZE (included) WGT. PKG. NEUTRAL KITS (FIELD INSTALLED ONLY) ORDER MODEL # 96 1 NEU407 A N GS1202B20M / / M 2" 46 1 INSTALLED + Metered unit not UL listed Does not meet NEC Code B Y GS3161B12UL / /0 2713G 1 1 /4" 32 1 Factory Installed B Y GS3262B25UL / G 2 1 /2" 48 1 Factory Installed B Y GS3464B01UL / or Order (2) 1/ G Separately NEUTRAL NEUTRAL KITS (FIELD INSTALLED ONLY) ORDER MODEL # Factory Installed Switches 7 Three Phase 240, 120/240 Volts AC FIG. UL MODEL NUMBER Three Phase 600 Volt AC FIG. UL MODEL NUMBER 104 AMPS WIRE RANGE CABINET HUB* UNIT STD. VOLTS PHASE MAIN STANDBY (CuAl) SIZE (included) WGT. PKG. C Y GS3262G** G C Y GS3402B01UL C Y GS3404B01UL ** Light Duty Transfer Switches AMPS VOLTS PHASE WIRE RANGE CABINET HUB* UNIT STD. MAIN STANDBY (CuAl) SIZE (included) WGT. PKG. C Y GS3161B12UL /0 2713G 1 1 /4" 32 1 NEU102 C Y GS3262B25UL G 2 1 /2" 48 1 NEU202 C Y GS3464B01UL * For Hub Model Number see Table on page 110 Order Separately NEUTRAL KITS (FIELD INSTALLED ONLY) ORDER MODEL # 45 1 INSTALLED (3) or 4423G Order NEU407 (3) Separately (3) or 4423G Order (3) NEU407 Separately NEUTRAL KITS (FIELD INSTALLED ONLY) ORDER MODEL # (3) or 4423G Order NEU407 (3) Separately

46 Transfer Switches Technical Data REPLACEMENT PARTS CABINET DIMENSIONS MODEL CABINET ENCLOSURE KNOCKOUT NUMBER UTILITY GENERATOR HEIGHT WIDTH DEPTH DEPTH SIZE STYLE FIGURE SWITCH BLOCK SWITCH BLOCK A B C D GS1101B12UL 139C5072G10 139C5072G G A 27-1/2" 13-5/8" 5-3/4" 10-5/8" 1 GS1201B20UL 139C4030G4 139C5072G G A 33-1/2" 16-5/8" 5-3/4" 10-5/8" 2 GS1202B20M 139C4030G4 139C4030G4 4016M B 40-1/4" 16-5/8" 5-3/4" 10-5/8" 2 GS1202B20UL 139C4030G4 139C4030G4 3616G A 33-1/2" 16-5/8" 5-3/4" 10-5/8" 2 GS1402B01UL 455C412G14 139C4030G4 4318G A 43-3/4" 18-1/4" 8-1/2" 14-1/8" 3 GS1404B01UL 455C412G14 455C412G G A 43-3/4" 18-1/4" 8-1/2" 14-1/8" 3 GS3161B12UL 139C5072G20 139C5072G G A 27-1/2" 13-5/8" 5-3/4" 10-5/8" 1 GS3161G 1509G A 15" 9" 5" 6-1/2" 5 GS3262B25UL 139C4030G3 139C4030G3 3616G A 33-1/2" 16-5/8" 5-3/4" 10-5/8" 2 GS3262G 3016G A 30" 16" 8-1/2" 12" 6 GS3402B01UL 455C412G14 139C4030G3 4423G A 44-3/4" 23-3/4" 8-1/2" 14-1/8" 4 GS3404B01UL 455C412G14 455C412G G A 44-3/4" 23-3/4" 8-1/2" 14-1/8" 4 GS3464B01UL 455C412G14 455C412G G A 44-3/4" 23-3/4" 8-1/2" 14-1/8" 4 Transfer Switch Neutral Kits MODEL NUMBER UNIT WGT. LBS. WIRE RANGE NEU102 1 (5) 12-1/0 NEU202 1 (2) 14-1/0, (3) NEU407 2 (2) 14-1/0, (3) OR (2) 1/0-250 Transfer Switches Cabinet Dimensions (FIG. A) (FIG. B) Transfer Switches Knockout Configurations (FIG. 1) (FIG. 2) (FIG. 3) (FIG. 4) (FIG. 5) (FIG. 6) B = 1", 1-1/4", 1-1/2" C = 1-1/4", 1-1/2", 2" D = 2", 2-1/2", 3" E = 1", 1-1/4", 1-3/4" F = 1-1/4", 1-3/4", 2" G = 1/2", 3/4", 1" I = 11/16" J = 2", 2-1/2", 3", 3-1/2" R = 3/4", 1", 1-1/4", 1-1/2", 2" U = 1/4" Transfer Switches 105

47 Power Inlet Features and Benefits Save Costly Installation Time G90 Galvanized steel with superior electro-deposition paint finish provides excellent corrosion protection All in one construction for factory assured terminations Rolled edge door for cord protection Cover design allows cords to exist while maintaining the NEMA 3R integrity Padlockable door to help prevent unauthorized access Deadfront construction prevents accidental contact with live parts UL listed U030N A U020N B U030N C U050N Power Inlets FIG. UL MODEL NUMBER RECEPTACLES AMPS VOLTS HEIGHT WITDTH DEPTH A Y U020N L / /8" 6-3/4" 5-3/16" Switches 7 B Y U030N L / /8" 6-3/4" 5-3/16" C Y U050N CS6375* / /8" 6-3/4" 5-3/16" * CS6375 is a California Standard, 3-pole / 4-wire grounded non-nema 106

48 Ranch Panel Application Information The Midwest Ranch Panel provides a reliable and convenient solution for meter socket and maximum circuit layout flexibility. Designed and manufactured to meet EUSERC standards, these high quality NEMA 3R meter centers are a superior solution to a wide range of specific applications. Increased durability and flexability, combined with ease of installation, add up to lower installed cost. Features and Benefits Electrical Ratings 200 Main Amp Rating Underwriter Laboratories Listed Feed through lugs V, Single-Phase 3-wire Enclosure NEMA 3R enclosure Suitable for surface mounting Wide box with generous wire bend space for inside feed of overhead or underground applications Removable side-opening door 3 concentric knockouts Breaker Panel Space for parallel secondary disconnect Series rated 22kAIC main breaker Factory installed bonded neutral Combination slotted/roberson neutral screws Minimum 100% neutral terminations Room for two neutral wires per hole Solid, extra long neutral bar Accepts 1 or 1/2 circuit breakers - total of 8 singlepole or 4 double-pole provisions. Surface - Metered Model Number RS2453C Main AMP Rating 200 Maximum Spaces 1 Breaker 1/2 Breaker 1-Pole 2-Pole 1-Pole 2-Pole Total 1-Pole Spaces 8 Type of Feed Overhead/Underground Transfer Switches 107

49 Parts & Accessories 108

50 Parts & Accessories TEMPORARY ADAPTERS (Not UL listed) See page 88 for larger images AD AD AD ADAPTS ADAPTS ADAPTS TO TO TO 15 AMP., 125 VOLT 30 AMP., 125 VOLT 30 AMP., 125 VOLT 15 AMP., 125 VOLT 50 AMP., 125/250 VOLT 15 AMP., 125 V. 10 PK. ONLY 10 PK. ONLY 10 PK. ONLY RECEPTACLES AND ANGLE PLUGS Receptacles Angle Plugs Receptacles on Plates NEMA CONFIGURATIONS AMP. VOLTAGE MODEL NUMBER MODEL NUMBER MODEL NUMBER 5-20 R R2 DUPLEX (See Below) ANSI C R-32-U BR32U 1 C32U PR32U 30 AMP. 125 VOLT R32U 2 (Travel Trailer Use Only) 10-30R /250 BR33 1 C33 PR R /250 BR34 1 C34 PR R /250 BR53 1 C53 PR R /250 BR54U 1 C54U PR54U 18-60R / C R /250 BR64U 1 C64U PR64U 1 Receptacle is complete with bracket to base mount into unit. 2 Bracket not included. Mounts directly on dead front. BR54U C54U PR54U Post Only (With cover) FEATURES 5-20R2GFCI 5-20R2 Post only with 3 wire openings (back and both sides) Earth burial and pad mounted Terminal bar assembly with loop feed lugs standard Surface mount units may be field installed on these posts (Not UL listed) Swing-down hasp (latch) for padlock provision Painted 16 gauge galvanized steel MODEL DIMENSIONS FACTORY INSTALLED STD. NUMBER DESCRIPTION W H D TERMINAL ASSEMBLY PKG Parts & Accessories P5 POST Pad Mount /2 4-1/2 LT200B350 1 P6 POST Earth Burial /2 4-1/2 LT200B

51 Parts & Accessories Post Extensions EK126 EK129* 6PT (6") Post Models 9PT (9") Post Models Kit consists of: (1) Post Extension Bracket, (2) 1/2" Bolts, (2) 1/2" Nuts, (4) 1/2" Flatwashers. Dimensions: 18"L x 6"W or 9"W Mounting Bracket 265A6218G1 For mounting FS box to post for field installation of TV or telephone jacks. Post Stake *Add CW for WEPCO Approved Model MS62 Kit consists of: (1) Post Stake Bracket, (2) 1/2" Bolts, (2) 1/2" Nuts, (4) 1/2" Flatwashers. Dimensions: 44"L x 3"W or 1"D Sealing Ring ASR1 Screw Style Sealing Ring for Ring-Type Meter Sockets Tie Bars SNPR1 Snap-On Style Sealing Ring for Ring-Type Meter Sockets Top Barrier Kit MSB 14T Accessories 8 Stabilizer Base & Stabilizer Foot Kit FBEM9 Earth Burial Installation 110 Top Barrier for 14 x 26 surface models. Isolates load conductors in meter compartment SFEM6 SFEM9 6" Stabilizer Foot Kit 9" Stabilizer Foot Kit Television/Telephone Add-On SFEM9 TTV100 Telephone and TV Add-on accessory bolts on at ground level to the back of a padmount post, earth-burial post, or a wall. The open back and open bottom make for easy wiring. Factory or field-installed Telephone/TV receptacle may be field replaced with data (Cat5) or other similar feature receptacle. Includes in-use cover. Unit is non-nema and non-ul. Bolt-On Hub (Standard Pkg Qty in 10 pcs.) Closure plate is standard with most Midwest products. Order appropriate hub from chart below. MODEL NUMBER HUB SIZE MIDWEST HUB UNIVERSAL HUB 3/4" B07 1" B10 U10 1-1/4" B12 U12 1-1/2" B15 U15 2" B20 U20 2-1/2" B25 U25 3" U30 3-1/2" U35 4" U40 CLOSURE PLATE SMALL B01 U01 CLOSURE PLATE LARGE U04 *For replacement hub screws, order B01, U01 or U04 as appropriate. Circuit Breaker Filler Plates MODEL 265A5003P1 265A5003P2 265A5003P11 265A5003P12 DESCRIPTION 1" Metal 2" Metal 1" Plastic 2" Plastic

52 Parts & Accessories Pullers, Fuse Blocks, Fuse Holders Model Number Wire Range (CuAl) Amp (Maximum) FH Cu Only 30 FH Cu Only 20 FH Cu Only 30 NF NF652 (Pullout For NF65) Model Number Wire Range (CuAl) Amp (Maximum) FH /0 100 FHL /0 100 FH1012 (Pullout for FH101 and FHL101) Model Number Wire Range (CuAl) Amp (Maximum) FH FH NF6523 (Pullout for U0653P) FR352 (Pullout for P035F, FR35, FR39) FR35R FR35R (Fuse Block and Pullout for U035F2) FR352R (Pullout for U035F2, FR35R) Model Number Wire Range (CuAl) Amp (Maximum) FR FR FR FR FR FH682 (Pullout for FR67, FR65, FR66, FR69, FR64X2, FR65X2, FR67X2) Parts & Accessories Model Number Wire Range (CuAl) Amp (Maximum) FR64X FR65X FR FR67X2 12-1/

53 Parts & Accessories Circuit Breakers C O DE MIDWEST MODEL NUMBER G.E. MODEL NUMBER 1" MODULE 1/2" MODULE AMP VOLTAGE NO. OF POLES CIRCUIT BREAKER DESCRIPTION STD. PKG. Accessories 8 Single Pole 120/240 Volt, 10,000 AIC Plug-In A CB115 THQL /240 1 Plug-In 6 B CB120 THQL /240 1 Plug-In 6 C CB130 THQL /240 1 Plug-In 6 D CB140 THQL /240 1 Plug-In 6 E CB150 THQL /240 1 Plug-In 6 F CB115T* THQP /240 1 Plug-In 12 G CB120T* THQP /240 1 Plug-In 12 J CB150T* THQP /240 1 Plug-In 12 * Models ending in T (1/2" Thinline breakers) not available for all load centers. Consult Manufacturer. Double Pole 120/240 Volt, 10,000 AIC Plug-In K CB220 THQL /240 2 Plug-In 3 L CB230 THQL /240 2 Plug-In 3 M CB240 THQL /240 2 Plug-In 3 N CB250 THQL /240 2 Plug-In 3 O CB220T* THQP /240 2 Plug-In 6 P CB230T* THQP /240 2 Plug-In 6 R CB250T* THQP /240 2 Plug-In 6 S CB260 THQL /240 2 Plug-In 3 T CB270 THQL /240 2 Plug-In 3 U CB2100 THQL /240 2 Plug-In 3 V CB2200B TQDL /240 2 Plug-In 1 V5 CB2150B TQDL /240 2 Plug-In 1 * Models ending in T (1/2" Thinline breakers) not available for all load centers. Consult Manufacturer. GFCI Single and Double Pole, 10,000 AIC W GFI115 THQL1115GF /240 1 Ground Fault Circuit Interrupter 1 X GFI120 THQL1120GF /240 1 Ground Fault Circuit Interrupter 1 Y GFI130 THQL1130GF /240 1 Ground Fault Circuit Interrupter 1 Z GFI220 THQL2120GF /240 2 Ground Fault Circuit Interrupter 1 AA GFI230 THQL2130GF /240 2 Ground Fault Circuit Interrupter 1 AB GFI240 THQL2140GF /240 2 Ground Fault Circuit Interrupter 1 AC GFI240 THQL2150GF /240 2 Ground Fault Circuit Interrupter 1 Double Pole Bolt-In 240 Volt, 10,000 AIC BB CB2101 TQD22100WL Amp Bolt-On 1 CC CB2151 TQD22150WL Amp Bolt-On 1 DD CB2201 TQD22200WL Amp Bolt-On 1 Special Purpose Breakers 240 Volt, 10,000 AIC EE CBL Bolt-On w/auxiliary Load Lugs 1 FF CBL Bolt-On w/auxiliary Load Lugs 1 GG CBL Bolt-On w/auxiliary Load Lugs 1 HH LCB Bolt-On w/auxiliary Load Lugs 1 II LCB Bolt-On w/auxiliary Load Lugs 1 JJ LCB Bolt-On w/auxiliary Load Lugs 1 KK CBT Plug-In for 100 T Series 1 LL CBT Bolt-In for 200 T Series 1 MM CBT2201N Bolt-In, Non-Auto Bkr. T Series 1 NOTE: Factory added modification parts to breakers, not available. Plug-in 240 Volt, 22,000 AIC NN CB4200H THQMV200WLBP ø Plug-in OO CB4150H THQMV150WLBP ø Plug-in PP CB2100H THHQL ø Plug-in 112

54 Parts & Accessories Circuit Breakers CB115 A-E CB115T F-J CB220 K-N, S-U CB220T O-R CB2200B V5-V GFI115 W-AC CB2201 BB-DD CBT2201 LL-MM CBL2201 EE-GG Parts & Accessories LCB2201 HH-JJ CBT2102 KK CB4200H NN-PP 113

55 Parts & Accessories Load Center Interiors Part Number Circuits Volts Amps Line Lug Size Neutral Lug Size LC31X #14-1/0 CU AL None LC32X / #14-1/0 CU AL None LC33N / #14-1/0 CU AL (2)#14-1/0, (2)#14-4 CU AL LC33N1T 3 120/ (2)#14-1/0 CU AL/Phase (2)#14-1/0, (2)#14-4 CU AL LC31N #14-1/0 CU AL (2)#12-2 CU AL LC33N / #14-1/0 CU AL (4)#14-2 CU AL LC44X / #14-1/0 CU AL None LC44X / (2)#14-1/0 CU AL None LC55N1T 5 120/ (2)#14-1/0 CU AL/Phase (2)#14-1/0, (2)#14-4 CU AL LC55N / #14-1/0 CU AL (2)#14-1/0, (2)#14-4 CU AL LC88PC 8 120/ #6-250KCMIL None LC88X / (2)#1-300KCMIL CU AL None LC1212PC / #6-250KCMIL None PC2LC 2 120/ #6-2/0 CU AL None LCBS 4 120/ #1-4/0 #1-4/0, #6-2/0, #14-4 LCBNS 1 120/ #1-4/0 #1-4/0, #6-2/0, #14-4 LCTL 4 120/ #1-4/0 #1-4/0, #6-2/0, #14-4 LCTNL 4 120/ #1-4/0 #1-4/0, #6-2/0, #14-4 LC31X3 LC32X1 LC33N1 Accessories 8 LC33N1T LC31N3 LC33N7 114

56 Parts and Accessories Load Center Interiors Image unavailable, consult manufacturer LC44X1 LC44X2 LC55N1T Image unavailable, consult manufacturer LC55N1 LC88PC LC88X2 LC1212PC PC2LC LCBS Parts & Accessories LCBNS LCTL LCTNL 115

57 Parts & Accessories Lug Assemblies Part Number Lug Size and Qty. NI60B2 (4)#14-4 CU AL NEU102 (5)#12-1/0 CU AL NI100B2 (5)#14-1/0 CU AL NEU202 (2)#14-1/0, (3)#6-250KCMIL CU AL NI200 (3)1/0-250KCMIL, (3)#12-1/0 CU AL NI200A5 (3)1/0-250KCMIL, (3)#12-1/0 CU AL NEU407 (2)#14-1/0, (3)#2-600KCMIL or (2)1/0-250KCMIL CU AL NI400A1 (2)1/0-600KCMIL, (3)1/0-250KCMIL CU AL GL3 (2)#12-2 CU AL GL6 1/0 Ground Lug NI60B2 NEU102 NI100B2 NEU202 NI200 NI200A5 NEU407 NI400A1 GL3 GL6 Accessories 8 Meter Door Replacement Kits Meter door replacement kits are available for Service Entrance, Temporary Power, and RV metallic metered units. Please consult manufacturer to ensure the proper kit is ordered for your model. 116

58 Parts & Accessories Loop Feed Lug Terminal Bars Part Number Load Amps Load Lugs Line Amps Line Lugs LT100B (2)#14-1/0 CU AL Per Phase 200 (2)#1-300KCMIL CU AL Per Phase LT100B (2)#14-1/0 CU AL Per Phase 200 (2)#6-350KCMIL CU AL Per Phase LT100S (1)#14-1/0 CU AL Per Phase 200 (2)#1-300KCMIL CU AL Per Phase LT100S (2)#14-1/0 CU AL; (4)#14-4 CU AL 200 (6)#1-300KCMIL CU AL LT100S (2)#14-1/0 CU AL; (4)#14-4 CU AL 200 (6)#1-350KCMIL CU AL LT200B (2)#2-250KCMIL CU AL Per Phase 200 (2)#6-350KCMIL CU AL Per Phase LT200B350RF 200 (2)#14-1/0 CU AL Per Phase 200 (3)#6-300KCMIL CU AL Per Phase LT200S (1)#2-250KCMIL CU AL Per Phase 200 (2)#6-350KCMIL CU AL Per Phase LT200SS 200 (2)#2-250KCMIL CU AL Per Phase 200 3/8-16 Double Stud Per Phase LT100B250 LT100B350 LT100S250 LT100S300 LT100S350 LT200B350 LT200B350RF LT200S350 LT200SS Parts & Accessories 117

59 Parts & Accessories Meter Bases 100 Amp sockets for models manufactured after February 1995 Replacement Line Lug Optional Model No. Type Rating Lug Style Wire Range Neutral Kit Description MSM100EZ Ring-Type 100 Lay-in #6-350KCMIL EZ-Site Underground Surface Panels MSR100EZ Ringless 100 Lay-in #6-350KCMIL EZ-Site Underground Surface Panels MSM Ring-Type 100 Lay-in #6-350KCMIL MSBN4 9" x 30" Surface Panels MSR Ringless 100 Lay-in #6-350KCMIL MSBN4 9" x 30" Surface Panels MSM100P9 1 Ring-Type 100 Lay-in #6-350KCMIL MSBN4 9PT Single Sided Posts MSR100P9 Ringless 100 Lay-in #6-350KCMIL MSBN4 9PT Single Sided Posts MSM10014 Ring-Type 100 Lay-in #6-350KCMIL MSBN4 11" Wide and 14" wide Surface Panels MSR10014 Ringless 100 Lay-in #6-350KCMIL MSBN4 11" Wide and 14" wide Surface Panels Neutral Factory installed in EZ-Site (Temporary Power) enclosure 100 Amp sockets for models manufactured between 1984 and February 1995 Replacement Line Lug Optional Model No. Type Rating Lug Style Wire Range Neutral Kit Description MS1H Ring-Type 100 Lay-in #6-1/0 MSBN1A Post Models, 14" wide Surface Panels MS1S 1 Ring-Type 100 Lay-in #6-1/0 MSBN1A Surface Mount, Rear Socket on Posts MSR1H Ringless 100 Lay-in #6-1/0 MSBN1A Post Models, 14" wide Surface Panels MSR1S Ringless 100 Lay-in #6-1/0 MSBN1A Surface Mount, Rear Socket on Posts 200 Amp sockets for models manufactured after 1984 Replacement Line Lug Optional Model No. Type Rating Lug Style Wire Range Neutral Kit Description MSM Ring-Type 200 Lay-in #6-350KCMIL MSBN4 14" wide Surface Panels MSR20014 Ringless 200 Lay-in #6-350KCMIL MSBN4 14" wide Surface Panels MW200M 1 Ring-Type 200 Box Style 1/0-350KCMIL MSBN4 All Other Panels and Post Units MW200R 1 Ringless 200 Box Style 1/0-350KCMIL MSBN4 All Other Panels and Post Units MSMS 1 Ring-Type 200 Lay-in 28" and 18" Series Service End Surface Mount Accessories 8 MSRS 1 Ringless 200 Lay-in 28" and 18" Series Service End Surface Mount MSMP 1 Ring-Type 200 Box Style 28" and 18" Series Service End Posts MSRP 1 Ringless 200 Box Style 28" and 18" Series Service End Posts MS200LBM +, 2 Ringless 200 Lay-in Lever Bypass + Includes lever bypass for 034 models 1 Midwest Electric manufactured meter socket only. 2 Midwest Branded Lever Bypass Meter Socket 118

60 Parts & Accessories Meter Bases MSM MSR100P9 MSM20014 MW200R MW200M MS1S MSMS MSRS MSMP MSRP MS200LBM MS5-(5th Jaw) 1 1 Midwest Electric manufactured meter socket only. Parts & Accessories MSBN1A MSBN4 For models manufactured prior to 1984 Consult Manufacturer for replacement socket. 119

61 Application Data NEMA Receptacle Configurations The configurations shown below all comply with National Electrical Manufacturers Association (NEMA) standards. These configurations represent a significant breakthrough on insuring the proper application and use of wiring devices to safeguard against accidents. This breakthrough was accomplished with the completion of a systematic grouping of non-interchangeable general purpose receptacle and plug configurations. Use of NEMA s unique configuration design for standard usage current and voltage ratings reduce the unsafe interchangeability of devices which existed prior to their adoption. STRAIGHT BLADE VOLTAGE 15 AMPERE 20 AMPERE 30 AMPERE 50 AMPERE 60 AMPERE LOCKING 15 AMPERE 20 AMPERE 30 AMPERE 125V R 5-30R 5-50R L-5 L5-20R L5030R 2-Pole 3-Wire Grounding 250V 6 277V AC 7 480V AC R 6-30R 6-50R 7-20R 7-30R 7-50R (Reserved for Future Configurations) L-6 L-7 L-8 L6-20R L7-20R L8-20R L6-30R L7-30R L8-30R 600V AC 9 (Reserved for Future Configurations) L-9 L9-20R L9-30R 125/250V R 10-30R 10-50R R-33 R-53 L-10 L10-20R L10-30R 3-Pole 3-Wire 3Ø250V 11 3Ø480V R 11-30R 11-50R (Reserved for Future Configurations) L-11 L-12 L11-20R L12-20R L11-30R L12-30R 3Ø600V 13 (Reserved for Future Configurations) L-13 L13-30R 3-Pole 4-Wire Grounding 125/250V 14 3Ø250V 15 3Ø480V 16 3Ø600V R 14-30R 14-50R 14-60R R-34 R-54-U 15-20R 15-30R 15-50R 15-60R (Reserved for Future Configurations) (Reserved for Future Configurations) L-14 L-15 L-16 L-17 L14-20R L15-20R L16-20R L14-30R L15-30R L16-30R L17-30R 3ØY 120/208V R 18-30R 18-50R 18-60R R-54 L-18 L18-20R L18-30R Other Receptacles CONFIGURATION VOLTAGE AMPERAGE DESCRIPTION 125/ R32U - Travel Trailer Use Only (ANSI C ) 125/ L6-50R (63CM69) Twist Lock L5-50R (63CM70) Twist Lock Data 9 120

62 Application Data Allowable Ampacities of Insulated Conductors Rated 0 through 2000 Volts, 60 C to 90 F (140 to 194 F) Not More Than Three Current- Carrying Conductors in Raceway or Cable or Earth (Directly Buried), Based on Ambient Temperature of 30 C (86 F) SIZE TEMPERATURE RATING OF CONDUCTOR SIZE AWG kcmil 60 C (140 F) TYPES TW, UF 75 C (167 F) TYPES FEPW, RH, RHW, THHW, THW, THWN, XHHW, USE, ZW 90 C (194 F) TYPES TBS, SA, SIS, FEP, FEPB, MI, RHH, RHW-2, THHN, THHW, THW-2, THWN-2, USE-2, XHH, XHHW, XHHW-2, ZW-2 60 C (140 F) TYPES TW, UF 75 C (167 F) TYPES RH, RHW, THHW, THW, THWN, XHHW, USE 90 C (194 F) TYPES TBS, SA, SIS, THHN, THHW, THW-2, THWN-2, RHH, RHW-2, RHH, RHW-2, USE-2, XHH, XHHW, XHHW-2, ZW-2 COPPER ALUMINUM OR COPPER-CLAD ALUMINUM / /0 2/ /0 3/ /0 4/ / CORRECTION FACTORS Ambient For ambient temperatures other than 30 C (86 F), multiply the allowable ampacities shown above by the Ambient Temp. C appropriate factor shown below. Temp. F Approximate Voltage Drop (Copper Conductor) Wire Size AWG or Per Ampere Per 100 feet 80% Power Factor Single MCM Phase Phase Three AWG kcmil Unless otherwise specifically permitted elsewhere in this Code, the overcurrent protection for conductor types marked with an obelisk ( ) shall not exceed 15 amperes for No. 14, 20 amperes for No. 12, and 30 amperes for No. 10 copper; or 15 amperes for No. 12 and 25 amperes for No. 10 aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. 121 Application Data

63

64 Rep Offices and Warehouses 1 Midwest Electric Products, Inc. Mankato, MN Phone: (507) FAX: (507) Canada, Hawaii and Puerto Rico 7 Bishop & Brogdon Atlanta, GA Phone: (404) FAX: (404) Bixler Marketing Group Council Bluffs, IA Phone: (712) FAX: (712) Arthur Boyle Company, Inc. Indianapolis, IN Phone: (317) FAX: (317) Gumersell Cashdan, Inc. Farmingdale, NY Phone: (631) FAX: (631) G.N. Deperro Company Detroit, MI Phone: (313) FAX: (313) Electrorep Sausalito, CA Phone: (415) FAX: (415) Electra Sales of North Texas, Inc. Irving, TX Phone: (972) FAX: (972) E-Tel Houston, TX Phone: (713) FAX: (713) Schwind-Berry, Inc. Milwaukee, WI Phone: (414) FAX: (414) SEGI Tempe, AZ Phone: (480) FAX: (480) SEGI N. Salt Lake, UT Phone: (801) FAX: (801) T.F. Farmer Company Greensboro, NC Phone: (336) FAX: (336) L.W. French, Inc. Glen Allen, VA Phone: (804) FAX: (804) Gemco Sales, Inc. Pittsburgh, PA Phone: (412) FAX: (412) J.R. Bovyer Electrical Sales of OH Brooklyn Heights, OH Phone: (330) FAX: (330) Schaeffer Sales, Inc. St. Louis, MO Phone: (314) FAX: (314) West Coast Sales Auburn, WA Phone: (253) FAX: (253) Curtis H. Stout, Inc. Little Rock, AR Phone: (501) FAX: (501) Hardcastle Electrical Sales Bowling Green, KY Phone: (270) FAX: (270) Electrical Products of Oklahoma Oklahoma City, OK Phone: (405) FAX: (405) Tulsa, OK Phone: (918) FAX: (918) John Moore & Associates, Inc. La Vergne, TN Phone: (615) FAX: (615) Syn-Tech, Inc. Kenner, LA Phone: (504) FAX: (504) MWE, Inc. N. Kansas City, MO Phone: (800) FAX: (816) Schmitz Electrical Sales Elk Grove Village, IL Phone: (847) FAX: (847) O.T. Hall & Son, Inc. Millersville, MD Phone: (410) FAX: (410) Darmac Agencies Ltd. Burnaby, B.C., CANADA Phone: (604) FAX: (604) Lesco, Inc. Minneapolis, MN Phone: (763) FAX: (763) Metra Associates Deerfield Beach, FL Phone: (954) FAX: (954) Theovine, Inc. Lachine, Quebec, CANADA Phone: (514) FAX: (514) David Role & Co. Woburn, MA Phone: (781) FAX: (781) J.R. Schmidt & Associates Denver, CO Phone: (800) FAX: (303) Pollart Electrical Sales Company, Inc. Bensalem, PA Phone: (800) FAX: (215) Billings, MT Phone: (406) FAX: (406) Electro-Lines, Inc. Syracuse, NY Phone: (315) FAX: (315) Midwest Electric Products, Inc. P.O. Box 910 Mankato, MN Phone (507) Fax (507)

U075CTL A Surface 50/30/20GFCI Twin Lugs

U075CTL A Surface 50/30/20GFCI Twin Lugs 3804 South Street 75964-7263, TX Nacogdoches hone: 936-569-794 Fax: 936-560-4685 llenwatson@elliottelectric.com U075TL00 00 Surface 50/30/20GFI Twin Lugs Midwest Electric roducts atalog Number Manufacturer

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Volume 1 Residential and Light Commercial CA E December

Volume 1 Residential and Light Commercial CA E December Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application

More information

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2 Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................

More information

6.1 Introduction Product Description... Application Description... Optional Features...

6.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................

More information

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Lighthouse Power Pedestals,

Lighthouse Power Pedestals, Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

Midwest Electric Products. Temporary Power

Midwest Electric Products. Temporary Power Midwest Electric roducts Temporary ower Midwest Electric roducts Temporary ower Midwest Electric provides the temporary power needed by construction trades prior to permanent service equipment installation.

More information

General Specifications for Lighthouse Power Pedestal

General Specifications for Lighthouse Power Pedestal Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate All Power Pedestals Must Meet the Following: Part I. General: 1.1 General Requirements- A.) Shall be tested and certified

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

RV Park Equipment Product Focus. Power Pedestals Distribution Equipment

RV Park Equipment Product Focus. Power Pedestals Distribution Equipment RV Park Equipment Product Focus s Distribution Equipment Eaton Corporation RV Park Hookups Product Eaton offers a complete portfolio of electrical products for your RV project including pedestals, distribution

More information

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

Midwest Electric Products. AC Disconnects

Midwest Electric Products. AC Disconnects Midwest Electric Products isconnects Midwest Electric Products pplication Information rticle 440 of the National Electrical ode applies to electric motor-driven air conditioning and refrigerating equipment

More information

Harbor Light Model HL General Specifications

Harbor Light Model HL General Specifications Harbor Light Model HL30100 General Specifications Rev.5 02-02-17 Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 Toll Free: 1-855-258-3939 Fax: 1-757-258-3988 ALL HARBOR LIGHT

More information

Switchgear Skid, C1192

Switchgear Skid, C1192 CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE

Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE BC Hydro Metering Kiosk BCH Metering and distribution kiosk built to BC Hydro distribution standards. Used for applications where secondary services are installed in weatherproof kiosks outside of a main

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Ohio Meter Mounting Equipment

Ohio Meter Mounting Equipment Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures

More information

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked

More information

UNDERGROUND SERVICES - SECONDARY

UNDERGROUND SERVICES - SECONDARY UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service

More information

CON EDISON EQUIPMENT

CON EDISON EQUIPMENT CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,

More information

Spring Test 10 due 05/11/2013

Spring Test 10 due 05/11/2013 Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock

More information

TERMINATION ENCLOSURE OPTIONS

TERMINATION ENCLOSURE OPTIONS TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

Meter Mounting Equipment. GA/AL/FL Panhandle Area

Meter Mounting Equipment. GA/AL/FL Panhandle Area Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers

More information

CABINET OPTIONS AND DESIGNATORS CODE LETTERS

CABINET OPTIONS AND DESIGNATORS CODE LETTERS CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Meter Mounting Equipment Florida Area Catalog

Meter Mounting Equipment Florida Area Catalog Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert

More information

Tennessee Area Meter Mounting Equipment

Tennessee Area Meter Mounting Equipment Tennessee Area Meter Mounting Equipment MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

Section 6 Electric Metering: Residential

Section 6 Electric Metering: Residential Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.

More information

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages FILE: Distribution Product Catalog!!IERVICEB.aJC Power Outlet Panels CONTENTS Description Class Pages Application Data.......................... 1140........ 36 Dimensions................................

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SECTION 500 METERING AND ASSOCIATED EQUIPMENT SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.

More information

Flashing Arrow Panel - 615/815 T/Y

Flashing Arrow Panel - 615/815 T/Y Flashing Arrow Panel - 615/815 T/Y All LED 15-Lamp Portable Flashing Arrow Panel Product Specifications American Signal Company FAP X 15 Page 1 of 8 6/11/17 2755 Bankers Industrial Drive Atlanta, GA 30360

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by

More information

Instrument Rated Metering Equipment

Instrument Rated Metering Equipment Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions

More information

Metering and Service Installation:

Metering and Service Installation: Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

Meter Mains - Without Bypass

Meter Mains - Without Bypass - 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR A 19 INCH RACK BASE MOUNT (HEATER/AC) (ENVIRONMENTAL FIELD TERMINAL CABINET) N. J. Specification No. Effective

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Static Phase Converters Rotary Phase Converters Double-Throw Switches Fused Disconnect Double-Throw Switches Non-Fused Disconnect Switches Stray

Static Phase Converters Rotary Phase Converters Double-Throw Switches Fused Disconnect Double-Throw Switches Non-Fused Disconnect Switches Stray Product LINE Guide Static Phase Converters Rotary Phase Converters Double-Throw Switches Fused Disconnect Double-Throw Switches Non-Fused Disconnect Switches Stray Voltage Isolation Power Factor Correction

More information

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Options. Meter base. Cooling Up fan to 22 kaic rated breakers SERVICE

Options. Meter base. Cooling Up fan to 22 kaic rated breakers SERVICE ADPA ADPA alid ADPA This marine-grade aluminum distribution panel is generally used for highways lighting control. It is a base This mount marine-grade design with aluminum the cables distribution entering

More information

SEA PORT MARINE CORP.

SEA PORT MARINE CORP. Sea Port 600 Dock Float Sea Port Floats are rotationally molded for seamless one piece construction. All units are manufactured from linear virgin polyethylene resin containing U.V. ray inhibitors and

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

Dry-Type Transformers Mini-Power Centers

Dry-Type Transformers Mini-Power Centers Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Power Mod. Introduction.

Power Mod. Introduction. Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

COMMERCIAL QUICK REFERENCE

COMMERCIAL QUICK REFERENCE COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information