1 New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
2 MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that empower life. We enable the amazing in countless everyday ways through our thoughtfully designed products and collaborative ingenuity. More than a manufacturing company, we are an active and engaged contributor in the movement of energy. We are energy at work. Milbank designs and builds solutions that move power for the residential, commercial, industrial, utility and transportation sectors. Milbank combines more than 85 years of expertise in electrical engineering and production with a commitment to develop and implement sustainable, integrated power solutions. A thirdgeneration, family-owned business, Milbank is headquartered in Kansas City, Mo. For more information, please visit METERING Milbank meter sockets have set the standard for quality since 97. With a 99.97% quality performance, thousands of products to meet your utility s requirements and tens of millions of sockets installed across the globe, our products help keep energy at work. And with stocking locations across the U.S., and our OneSERT program to help during emergency situations, our meter sockets are ready to go, wherever the job may be. ENCLOSURES & ENCLOSED CONTROLS When it comes to enclosures and enclosed control products, Milbank has it covered! We offer a complete line of junction boxes, telephone cabinet covers, transformer cabinets, touchscreen controls, wireways, pushbutton enclosures, consoles and thermal management products. We specialize in custom-built enclosures and are more than happy to design a solution for your specific project. Our commercial pedestals are easy to install, fast, safe and secure, and completely customizable. GENERATORS & ENERGY MANAGEMENT Milbank s standby and portable generators give you the peace of mind of living life uninterrupted during increasingly frequent power outages caused by severe weather, high demand and other situations. Our energy management systems give you reliable and sustainable ways to reduce both your energy costs and your impact on the environment. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
3 Table of Contents TABLE OF CONTENTS Air Conditioner Disconnects 0 & 60 amp AC disconnects amp AC disconnect with 0 amp GFCI receptacle... 7 Hot tub disconnects... 8 Single Position Sockets 00 amps, 4 terminals, ringless, solar amps, 4 terminals, ringless amps, 5 & 7 terminals, medium duty lever bypass, ringless amps, 5 terminals, medium duty lever bypass, ringless amps, 4 terminals, heavy duty lever bypass, ringless amps, 5 & 7 terminals, heavy duty lever bypass, ringless amps, 4,5 & 7 terminals, heavy duty lever bypass, ringless Meter Mains amps, 4 terminals, ringless amps, 4 terminals, lever bypass, ringless amps, 4 terminals, meter main with load center, ringless amps, 7 terminals, lever bypass, ringless... 0 amps, 4 terminals, lever bypass, ringless... 4 Cold Sequence, 00 & 400 amps, 7 terminals, lever bypass, ringless... 5 Multi-Position 00 amps, 4 terminals, ringless & ring type, vertical amps, 4 terminals, ringless amps, 4 terminals, ringless amps, 4 terminals, with single position lever bypass, ringless amps, 5 terminals, lever bypass, ringless, vertical amps, 5 terminals, lever bypass, ringless amps, 7 terminals, lever bypass, ringless... 4 Multi-Position Meter Mains 5 amps, 4 terminals, with single position lever, ringless & 00 amps, 4 terminals, ringless amps, 5 terminals, lever bypass, ringless... 8 Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
4 4 TABLE OF CONTENTS Table of Contents Transformer Rated 0 amps, 6 - terminals, plunger bypass, ringless amps, 6 - terminals, test switch provision, ringless amps, 6 - terminals, pre-wired, ringless... 4 Test switches, test switch work sheet... 4 CT Cabinets Polyphase Enclosures A base enclosures Pedestals Meter pedestal for pad mounting amps, 4 terminal, direct bury amps, 4 terminal, lever bypass, direct bury Temp Power Units 5, 4 terminal, ringless Parts & Accessories Circuit breakers and accessories Miscellaneous Commercial pedestals Generators SynapSwitch TM Reference information Index Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
5 Catalog Number Logic How our product catalog numbers are derived 5 CATALOG NUMBER LOGIC Milbank drawing number TG: Triplex ground QG: Quadplex ground Lugs (Ø or Ø, 50 or 600 kcmil) Single: K, K, K5, K7 Twin: K, K4, K6, K8 Utility specific designation U448-X-QG-5T9-K-BLG-ARE U: UL Listed S: Non-UL Listed UAP: UL, aluminum, painted U: UL Listed S: Non-UL Listed UAP: UL, aluminum, Hub Openings & Closing Plates -O Blank top -RL Small hub opening -R Large hub opening -XL Small closing plate -X Large closing plate -RXL Large hub opening adapted to small closing plate -RRL Large hub opening adapted to small hub opening -PXL Closing plate packed inside 5th terminal designation 5T6: installed at 6:00 5T9: installed at 9:00 -WL hub -YL ¼ hub -ZL ½ hub -DL hub -EL ½ hub -F hub -G ½ hub -H 4 hub BLG: Barrel lock / guard provision painted KK: Horn bypass BL: Barrel lock U7040-RL-TG-KK-5T9-BL-AUT Milbank drawing number TG: Triplex ground QG: Quadplex ground 5th terminal designation 5T6: installed at 6:00 5T9: installed at 9:00 Utility specific designation Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
6 6AC DISCONNECTS Air Conditioner Disconnects 0 & 60 Amps Fusible & Non-Fusible U80 U8 U8 Milbank s air conditioner disconnect has a removable hinged cover for ease of installation. Our compact design meets NEC wiring space requirements and also complies with NEC article For safe working conditions, our disconnect pullers may be removed and reinstalled in the OFF position. Additionally, padlock provisions are included on the front cover. As with other Milbank products, our enclosure is constructed of G90U galvanized steel and electrostatically finished with an attractive, light gray, baked powder coating. Our epoxy/polyester resin blend offers a finish that is both durable and fade-resistant Amps Ø 40 VAC Air Conditioner Disconnects Catalog Number Amps Type Max H.P. Weight (lbs.) Line/Load Wire Range Ground Wire Dimensions Wire Rating Range CU/AL CU AL D" W" H" CU C AL C U80 60 Non-Fusible 0.5 #4-# #-# # /75 60 /75 U8 60 Non-Auto 0.5 #4-# #-# # /75 60 /75 U8 0 Fusible.5 #4-# #4-# # /75 60 /75 U86 60 Fusible 0. #4-# #4-# # /75 60 /75 UL listed as Enclosed Pullout Switch Type R rainproof One-inch concentric knockouts Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
7 Air Conditioner Disconnects 60 Amps With 0 Amp GFCI Receptacle 7 AC DISCONNECTS U8-0GWR Specifications Meets NEC #0.6 requirements UL listed as Power Outlet Type R enclosure In-use cover* Duplex ground connector " concentric knockouts Ø, 40 volt 60 amp, non-fused 0 amp GFCI receptacle Reset/test button Weather and tamper resistant Meets NEC #406.8 requirements 60 Amps Ø, 40 VAC Air Conditioner Disconnect with GFCI Receptacle Catalog Number Type Max H.P. Weight (lbs.) Line/Load Wire Range Ground Wire Range CU/AL Dimensions Wire Rating CU AL D" W" H" CU C AL C U8-0GWR Non-Fusible 0 6 #4-# #-# # /75 60 /75 Disconnect Pullouts: To ensure the safest conditions, Milbank disconnect pullouts are reversible so they may be reinstalled in the OFF position. Padlock Provision: All units are designed with a padlock provision on the cover for security. *In-Use Cover: Cover is rated as an in-use cover (cover may be closed with cords plugged into receptacle). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
8 8 HOT TUB DISCONNECTS Hot Tub Disconnects Type R Enclosures U488-O-50GB U488-O-60GB Specifications 40 volt ground fault protection UL listed, Type R rainproof -pole, 50 or 60 amp GFCI breaker protection Compact size Three or four wire installation Ø, 0/40 VAC Standard package of Two extra one-pole breaker spaces 00 amp overall rating Easy to install 00 Amps Hot Tub Disconnect or Sub Panel Breaker Enclosure Type R Catalog Number Breaker Amps Type Weight (lbs.) Line/Load Wire Range Ground Wire Range CU/AL Dimensions CU AL D" W" H" U488-O-50GB 50 Breaker 8 #4-/0 #4-/0 #4-/0 7 8 U488-O-60GB 60 Breaker 8 #4-/0 #4-/0 #4-/0 7 8 Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
9 Single Position Sockets 00 Amps 4 Terminals Ringless 600 VAC 9 00 AMP SINGLE POSITION SOCKETS solar-friendly U594-XL-BLG 00 Amps 4 Terminals Ringless Single Position ØW Catalog Number Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U594-XL-BLG OH/UG C.P. #-/0 #-/0 None Hubs: Accepts standard meter socket hubs. Construction: Units are Type R for durable outdoor use, lockable and sealable. Connectors: Connectors will accept #4-/0 conductors. To isolate neutral remove bonding screw. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
10 0 5 AMP SINGLE POSITION SOCKETS Single Position Sockets 5 Amps 4 Terminals Ringless 600 VAC RL 7487-YL O U7487-O-TG 5 Amps 4 Terminals Ringless Single Position ØW Catalog Number Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U7487-YL-TG OH #6-/0 #6-/0 None U7487-RL-TG OH/UG H.O. #6-/0 #6-/0 None U7487-O-TG UG Blank #6-/0 #6-/0 None Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Fifth Terminal: For field-installed fifth terminal, order catalog number 5T8K. Connectors: Extruded aluminum connectors are tin plated. Ground: Units are supplied with a triplex ground (-TG)., Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
11 Single Position Sockets 00 Amps 4 Terminals Ringless 600 VAC 00 AMP SINGLE POSITION SOCKETS U70-RL-TG U7040-O-TG 00 Amps 4 Terminals Ringless Single Position ØW Catalog Number Service Hub Connectors CU/AL Bypass Dimensions Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Fifth Terminal: For field installed fifth terminal, order K5T. Ground: Units supplied with triplex ground. Connectors: Extruded aluminum connectors are tin plated. Knockouts D" W" H" 4 U70-RL-TG OH H.O. #6-50 None U7040-XL-TG OH/UG C.P. #6-50 None U7040-O-TG UG Blank #6-50 None ,,, Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
12 00 AMP LEVER BYPASS SOCKETS Single Position Sockets 00 Amps 4 Terminals Side Wireway 600 VAC U980-O U44-O-BL U5777-O Amps 4 Terminals Ringless Side Wireway Single Position ØW Catalog Number Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U980-O UG Blank #6-50 #6-50 None U44-O-BL UG Blank #6-50 #6-50 None U5777-O UG Blank 8-6 Studs #-50 None ,,, Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Connectors: Extruded aluminum connectors are tin plated. Ground: Units supplied with triplex ground. Fifth Terminal: For field installed fifth terminal, order K5T. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
13 Lever Bypass Single Position 5 Amps 5 & 7 Terminals Ringless 600 VAC 5 AMP LEVER BYPASS SOCKETS U7-RL-5T9-BL U860-XL-5T9-QG U757-RL 5 Amps 5 Terminals Ringless Lever Bypass Single Position ØW Catalog Number Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U7-RL-5T9-BL OH H.O. #6-/0 #6-/0 Lever , U860-XL-5T9-QG OH/UG C.P. #6-/0 #6-/0 Lever Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Lever Bypass: The lever operates bypass device only; it is not jaw clamping. Connectors: Extruded aluminum connectors are tin plated. Fifth Terminal: Factory installed in 9 o clock position., 5 Amps 7 Terminals Ringless Lever Bypass Single Positions Ø4W Catalog Number Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U757-RL OH H.O. #6-/0 #6-/0 Lever , Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Lever Bypass: The lever operates bypass device only; it is not jaw clamping (medium duty). Connectors: Extruded aluminum connectors are tin plated. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
14 4 00 AMP LEVER BYPASS SOCKETS Lever Bypass Single Position 00 Amps 5 Terminals Ringless 600 VAC U98-RL U99-XL 00 Amps 5 Terminals Ringless Single Position ØW Catalog Number Service Hub Connectors CU/AL Bypass Dimensions Knockouts D" W" H" 4 5 U98-RL OH H.O. #6-50 Lever U99-XL OH/UG C.P. #6-50 Lever Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Lever Bypass: The lever operates bypass device only; it is not jaw clamping (medium duty). Connectors: Extruded aluminum connectors are tin plated.,, Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
15 Lever Bypass Single Position 00 Amps 4 Terminals Ringless 600 VAC 5 00 AMP LEVER BYPASS SOCKETS U9800-RRL-QG-BL-NE U980-RXL-QG U94-XL U47-O-BL Amps 4 Terminals Ringless Single Position ØW Catalog Number Service Hub Connectors Dimensions Knockouts Bypass CU/AL D" W" H" 4 5 U9800-RRL-QG-BL-NE OH H.O. #6-50 Lever , U980-RXL-QG OH/UG C.P. #6-50 Lever , U94-XL UG C.P. #6-50 Lever , U47-O-BL UG Blank #6-50 Lever Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Fifth Terminal: For field installed fifth terminal, order as extra K866 for the U9800, U980, U47, and K865 for the U94. Bypass: The lever supplies clamping action on meter spades and also operates bypass device. Connectors: Extruded aluminum connectors are tin plated. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
16 6 00 AMP LEVER BYPASS SOCKETS Lever Bypass Single Position 00 Amps 5 Terminals Ringless 600 VAC U9550-RRL-QG U955-RXL-QG 00 Amps 5 Terminals Ringless Single Position ØW or ØW Catalog Number Service Hub Connectors CU/AL Bypass Dimensions Knockouts D" W" H" 4 U9550-RRL-QG OH H.O. #6-50 Lever U955-RXL-QG OH/UG C.P. #6-50 Lever ,, Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Bypass: The lever supplies clamping action on meter spades and also operates bypass device. Connectors: Extruded aluminum connectors are tin plated. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
17 Lever Bypass Single Position 00 Amps 7 Terminals Ringless 600 VAC 7 00 AMP LEVER BYPASS SOCKETS U9700-RRL-QG-BL U970-RXL-QG U490-O-BL Amps 7 Terminals Ringless Single Position Ø4W Catalog Number Service Hub Connectors CU/AL Bypass Dimensions Knockouts D" W" H" 4 4 U9700-RRL-QG-BL OH H.O. #6-50 Lever U970-RXL-QG OH/UG C.P. #6-50 Lever ,, U490-O-BL UG Blank #6-50 lever Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Bypass: The lever supplies clamping action on meter spades and also operates bypass device. Connectors: Extruded aluminum connectors are tin plated. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
18 8 0 AMP LEVER BYPASS SOCKETS Lever Bypass Single Position 0 Amps 4 Terminals Ringless 600 VAC U448-X U4778-X-BL 0 Amps 4 Terminals Ringless Single Position ØW Catalog Number Service Hub Connectors CU/AL Bypass Dimensions Knockouts D" W" H" 4 U448-X OH/UG C.P. 8" x 6 Studs Lever U4778-X-BL OH/UG C.P. 8" x 6 Studs Lever Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Bypass: The lever supplies clamping action on meter spades and also operates bypass device. Connectors: Units are supplied with 8" x 6 hex nuts with Belleville washers. Order K540 (single, 600 kcmil) or K50 (twin, 50 kcmil). Order two kits to cover both line and load. Fifth Terminal: For field-installed fifth terminal, order K865 as extra. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
19 Lever Bypass Single Position 0 Amps 5 & 7 Terminals Ringless 600 VAC 9 0 AMP LEVER BYPASS SOCKETS U46-X U49-X-BL U594-X 0 Amps 5 Terminals Ringless Single Position ØW Catalog Number Service Hub Connectors CU/AL Bypass Dimensions Knockouts D" W" H" 4 U46-X OH/UG C.P. 8" x 6 Studs Lever Amps 7 Terminals Ringless Single Position Ø4W Catalog Number Service Hub Connectors CU/AL Bypass Dimensions Knockouts D" W" H" 4 U49-X-BL OH/UG C.P. 8" x 6 Studs Lever U594-X OH/UG C.P. 8" x 6 Studs Lever Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Bypass: The lever supplies clamping action on meter spades and also operates bypass device. Connectors: Units are supplied with 8 x 6 hex nuts with Belleville washers. Order K44 (single, 600 kcmil) or K44 (twin, 50 kcmil). Order two kits to cover both line and load. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
20 AMP METER MAINS Meter Mains Amps 4 Terminals Ringless 0/40 VAC U499-XL-00 U989-XL-00 U990-XL-50 U798-O-00 U5757-O Terminals Ringless Meter Mains ØW Catalog Number Service Amps Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U499-XL-00 OH/UG 00 C.P. #6-/0 #6-/0 None, U989-XL-00 OH/UG 00 C.P. #6-/0 #6-/0 None, U990-XL-50 OH/UG 50 C.P. #-50 #/0-00 None U990-XL-00 OH/UG 00 C.P. #-50 #/0-00 None U798-O-00 UG 00 Blank #-50 #/0-00 None ,,, U5757-O-00 UG 00 Blank 8"-6 Studs #/0-00 None Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Circuit Breakers: The U499-XL-00 has a factory-installed 00 amp breaker. The U990-XL-50 and U990-XL-00 have factory installed Milbank UQFB-(AMP)-X breakers. The U798-O-00 has a factory-installed UQFB-00-X breaker. The U989-XL-00 is supplied with a 00 amp plug-in style breaker and has provisions for two -pole breakers. Fifth Terminal: For field-installed fifth terminal for U499 and U989, order 5T8K. For U990 and U798, order K5T. For U5757, order K865. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
21 Lever Bypass Meter Mains Amps 4 Terminals Ringless 0/40 VAC AMP LEVER BYPASS METER MAINS U74-XL-00-BL U79N-RXL-00-BL U540-RXL-00-BL 4 Terminals Ringless Meter Mains ØW Catalog Number Service Amps Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U74-XL-00-BL OH/UG 00 C.P. #6-/0 #6-/0 Lever , U79N-RXL-00-BL OH/UG 00 C.P. #6-50 #/0-00 Lever , U540-RXL-00-BL OH/UG 00 C.P. #6-50 #/0-00 Lever Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Circuit Breakers: The U74 is supplied with a factory-installed -pole, 00 amp plug-in breaker. The U79 unit is supplied with a factory installed Milbank UQFB-00-X -pole, 00 amp bolt-in breaker. Fifth Terminal: For field-installed fifth terminal, order K866. For a W network, use fifth terminal. Bypass: The lever bypass on the U74 operates the sliding bypass only; it is not jaw clamping (medium duty). The lever bypass on the U79N and U540 supplies clamping action on the meter spades and also operates the bypass device (heavy duty). Connectors: Extruded aluminum connectors are tin plated. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
22 00 AMP METER MAIN WITH LOAD CENTER Meter Main with Load Center Amps 4 Terminals Ringless U995-XL-00 U568-XTL-00-BL-NE U587-XL-00-BL U5898-O-00-BL Terminals Ringless Meter Main with Load Center ØW Catalog Number Service Amps Hub Circuits 5 Connectors CU/AL Line Bypass Dimensions Knockouts D" W" H" U995-XL-00 OH/UG 00 C.P. 4 #6-50 Lever , U568-XTL-00-BL-NE OH/UG 00 () C.P. 0 #6-50 None , U568-XTL-00-BL-NE OH/UG 00 () C.P. 8 #6-50 None , U587-XL-00-BL OH/UG 00 C.P. 8 #6-50 Lever 4 4 8,,,, U5898-O-00-BL UG 00 Blank 8 #6-50 None 4 7 4, Fifth Terminal: For a field-installable fifth terminal for U587 and U995, order K865. For the U568 and U5898, order K5T. Connectors: Extruded aluminum connectors are tin plated. Breakers: The U568, U587 and U5898 are rated K AIC with QN00H main breaker installed and have eight branch breaker provisions. The U995-XL-00 has a factory-installed UQFB-M-00 breaker and provisions for () double pole or (4) single pole circuit breakers., Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
23 Lever Bypass Meter Mains Amps 7 Terminals Ringless 0/40 VAC AMP LEVER BYPASS METER MAINS U77-XL-00-BL U5750-RXL-00-BL 7 Terminals Ringless Meter Mains Ø4W Catalog Number Service Amps Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U77-XL-00-BL OH/UG 00 C.P. #6-/0 #6-/0 Lever , U5750-RXL-00-BL OH/UG 00 C.P. #6-50 #/0-00 Lever Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Bypass: The lever on the U77 operates the bypass device only; it is not jaw-clamping (medium duty). The lever on the U5750 supplies clamping action on the meter spades and also operates bypass device (heavy duty). Connectors: Extruded aluminum connectors are tin plated. Breakers: The U77 is supplied with a factory-installed -pole, 00 amp plug-in breaker. The U5750 is supplied with a factory-installed Milbank UQFB-00 -pole, 00 amp bolt-on breaker. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
24 4 0 AMP LEVER BYPASS METER MAINS Lever Bypass Meter Mains 0 Amps 4 Terminals Ringless U485-X-/00-BL U40-O-/00 0 Amps 4 Terminals Ringless Meter Mains Ø Catalog Number Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U485-X-/00-BL OH/UG C.P. 8"-6 Studs #/0-00 Lever , U40-O-/00 UG Blank 8"-6 Studs #/0-00 Lever , Connectors: The line wire section is supplied with /8"-6 studs with hex head nuts and captive Belleville washers. For single lug connector kits, order K59 (50 kcmil) or K540 (600 kcmil). For twin lug connector kits, order K50 (50 kcmil). Breakers: The U40 and U485 are supplied with () bolt-on Milbank UQFBH-00 breakers. Bypass: The lever supplies clamping action on the meter spades and also operates the bypass device. Fifth Terminal: For field-installed fifth terminal, order catalog number K865. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
25 Cold Sequence Meter Mains 00 & 400 Amps For use on 480V services 5 COLD SEQUENCE METER MAINS U5767-X-00-CB-BL U5799-O-400-CB-BL 00 Amps 7 Terminals Circuit Breaker Disconnect Ahead of Meter Socket Ø4W Connectors CU/AL AIC Dimensions Knockouts Catalog Number Service Hub Bypass Line Load Rating D" W" H" 4 U5767-X-00-CB-BL OH C.P. /0-50 #6-50 Lever *See note 4 7 4, U5787-O-00-CB UG Blank /0-50 #6-50 Lever *See note ,, 400 Amps (0A Cont.) 7 Terminals Circuit Breaker Disconnect Ahead of Meter Socket Ø4W Connectors CU/AL AIC Dimensions Knockouts Catalog Number Service Hub Bypass Line Load Rating D" W" H" U5796-X-400-CB-BL OH C.P. () /0-500 () /0-500 Lever 0K 6 56, U5799-O-400-CB-BL UG Blank () /0-500 () /0-500 Lever 0K *AIC Ratings: Circuit breaker rated K AIC, 5K AIC, and 65K AIC. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
26 6 00 AMP MULTI- POSITION SOCKETS Vertical Multi-Position Sockets 00 Amps 4 Terminals Ringless 00 VAC U69-XL 00 Amps 4 Terminals Multi-Position Ringless Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U69-XL OH/UG C.P. #-50 #6-/0 None U69-XL OH/UG C.P. #-50 #6-/0 None U64-XL OH/UG C.P. #-50 #6-/0 * Amps upper socket & 00 Amps lower socket 4 Terminals Multi-Position Ring Type Connectors CU/AL Dimensions Knockouts Catalog Number Positions Service Hub Bypass Line Load D" W" H" 4 U780-O OH/UG Blank #-50 #6-/0 None 4 8 6, Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Fifth Terminal: For a field-mounted fifth terminal, order catalog number 5T8K. Connectors: Extruded aluminum connectors are tin plated. Bussing: x " aluminum bussing is supplied. * The U64-XL upper meter socket has a medium duty lever bypass and upper socket is 00 Amps, and the lower socket is 00 Amps. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
27 Multi-Position Sockets 00 Amps/Position 4 Terminals Ringless 00 VAC 7 00 AMP MULTI- POSITION SOCKETS U76-DL Amp/Position 4 Terminals Multi-Position Ringless Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U76-DL OH " #6-50 #6-/0 None , U76-DL OH " #6-50 #6-/0 None 4 4 6, U764-DL 4 OH " #6-50 #6-/0 None 4 6 6, U765-DL 5 OH " #6-50 #6-/0 None , U766-DL 6 OH " #6-50 #6-/0 None , Hubs: For proper hub selection, refer to the hub suffix chart on the Accessories page. Hub opening is supplied at each end. Extra opening is closed with a closing plate. Fifth Terminal: For field mounted fifth terminal, order catalog number K85 for each meter position. Connectors: Extruded aluminum connectors are tin plated. Bussing: Bussing is 5 6" x " aluminum. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
28 8 00 AMP MULTI-POSITION SOCKETS Multi-Position Sockets 00 Amps 4 Terminals Ringless 00 VAC U8-XL Amp per Position 4 Terminal Multi-Position End Wireway Ringless Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Line Load D" W" H" U8-XL OH C.P. #6-50 #6-/ , U8-XL OH C.P. #6-50 #6-/ , U84-XL 4 OH C.P. #6-50 #6-/ , U85-XL 5 OH C.P. #6-50 #6-/ , U86-XL 6 OH C.P. #6-50 #6-/ , 00 Amp per Position 4 Terminal Multi-Position End Wireway Ringless Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Line Load D" W" H" U60-XL OH C.P. #6-50 #6-/ , Hubs: For proper hub selection, refer to the hub suffix chart on the Accessories page. Hub opening is supplied at each end. Extra opening is closed with a closing plate. Fifth Terminal: For field mounted fifth terminal, order catalog number K85 for each meter position. Connectors: Extruded aluminum connectors are tin plated. Bussing: Bussing is 5 6 x aluminum. 60 has 00 Amp Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
29 Multi-Position Sockets 00 Amps/Position 4 Terminals Ringless 00 VAC 9 00 AMP MULTI- POSITION SOCKETS U5-X-K Amps 4 Terminals Multi-Position Ringless ØW Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 5 U5-X-K OH/UG C.P. #6-50 #6-50 None U5-X-K OH/UG C.P. #4-600 #6-50 None U54-X-K 4 OH/UG C.P. #4-600 #6-50 None U55-X-K4 5 OH/UG C.P. () #-600 #6-50 None U56-X-K4 6 OH/UG C.P. () #-600 #6-50 None Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Fifth Terminal: For a field-mounted fifth terminal, order catalog number K5T. Connectors: Extruded aluminum connectors are tin plated. Bussing: 5 6" x " aluminum bussing is supplied in the U5. 5 6" x aluminum bussing is supplied in the U5 U56. Overhead Service: Extention kits for 4, 5 & 6 gang sockets available. Consult factory. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
30 0 5 AMP MULTI- POSITION SOCKETS Multi-Position Sockets 5 Amps/Position 4 Terminals Ringless 00 VAC U764-XL NOTE Each unit is supplied with a 5 amp non jaw-clamping lever bypass block assembly in the far right meter position only. All remaining positions are 5 amp with no bypass Amps 5 Terminals Multi-Position Ringless Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U76-XL OH/UG C.P. #6-/0 #-50 See note U764-XL 4 OH/UG C.P. #6-/0 #-50 See note U765-XL 5 OH/UG C.P. #6-/0 #-50 See note ,,, Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Fifth Terminal: For a field-mounted fifth terminal, order catalog number 5T8K for tenant positions, and order K56 for the far right house power lever bypass socket. Connectors: Extruded aluminum connectors are tin plated. Bussing: x " aluminum bussing is supplied. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
31 Vertical Lever Bypass Multi-Position Sockets 00 Amps/Position 5 Terminals Ringless 00 VAC 00 AMP LEVER BYPASS MULTI- POSITION SOCKETS U5-X-5T9-BL 00 Amps 5 Terminals Multi-Position Ringless Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U5-X-5T9-BL OH C.P. #6-50 #6-/0 Lever , U5-X-5T9-BL OH C.P. #6-50 #6-/0 Lever Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Fifth Terminal: For a field-mounted fifth terminal, order catalog number 5T8K. Connectors: Extruded aluminum connectors are tin plated. Bussing: x " aluminum bussing is supplied. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
32 00 AMP LEVER BYPASS MULTI- POSITION SOCKETS Lever Bypass Multi-Position Sockets 00 Amps/Position 5 Terminals Ringless 600 VAC U754-X-5T9 (unit shown with connector kit -K59, order as extra) Amps 5 Terminals Multi-Position Ringless Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U75-X-5T9 OH/UG C.P. 8 x 6 studs #6-/0 Lever U75-X-5T9 OH/UG C.P. 8 x 6 studs #6-/0 Lever U754-X-5T9 4 OH/UG C.P. 8 x 6 studs #6-/0 Lever U755-X-5T9 5 OH/UG C.P. 8 x 6 studs #6-/0 Lever U756-X-5T9 6 OH/UG C.P. 8 x 6 studs #6-/0 Lever Fifth Terminal: The fifth terminal is factory installed in the 9 o clock position. May field-change to the 6 o clock position. Connectors: Aluminum extruded load side connectors are tin plated. For line side single lug connector kits, order K59 (50 kcmil) or K540 (600 kcmil) as extra. For twin lug connectors, order K50 (50 kcmil) or K54 (600 kcmil) as extra. Bussing: x " aluminum bussing is supplied. Lever Bypass: The lever operates bypass only; it is not jaw-clamping (medium duty). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
33 Lever Bypass Multi-Position Sockets 00 Amps/Position 5 Terminals Ringless 600 VAC 00 AMP LEVER BYPASS MULTI- POSITION U87-XT-5T Amps per Position 5 Terminals Multi-Position Ringless ØW Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U87-XT-5T9 OH () C.P. 8" x 6 Stud #6-50 Lever U87-XT-5T9 OH () C.P. 8" x 6 Stud #6-50 Lever U874-XT-5T9 4 OH () C.P. 8" x 6 Stud #6-50 Lever U875-XT-5T9 5 OH () C.P. 8" x 6 Stud #6-50 Lever U876-XT-5T9 6 OH () C.P. 8" x 6 Stud #6-50 Lever ,,,,, Hubs: Units supplied with two closing plates. To order as extra, refer to the hub suffix chart in the Accessories section. Connectors: Units supplied with 8-6 hex head nuts with Belleville washers on line side. Order connector kits K59 (50 kcmil), K540 (600 kcmil), K50 (() 50 kcmil) or K54 (() 600 kcmil). Bypass: Lever supplies clamping action on meter spades and also operates bypass device. Fifth Terminal: The fifth terminal is factory-installed in the 9 o clock position; may be field-changed to the 6 o clock position. Bussing: 8" x " aluminum bussing is supplied. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
34 4 00 AMP LEVER BYPASS MULTI- POSITION Lever Bypass Multi-Position Sockets 00 Amps 7 Terminals Ringless 600 VAC U7-XT Amps per Position 7 Terminals Multi-Position Ringless Ø4W Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Line Load D" W" H" U7-XT OH/UG () C.P. 8" x 6 Stud # U7-XT OH/UG () C.P. 8" x 6 Stud # U74-XT 4 OH/UG () C.P. 8" x 6 Stud # U75-XT 5 OH/UG () C.P. 8" x 6 Stud # U76-XT 6 OH/UG () C.P. 8" x 6 Stud # ,,,,, Hubs: Units supplied with two closing plates. To order as extra, refer to the hub suffix chart in the Accessories section. Connector Kits: For line side connector kits, order as extra K08 (50 kcmil), K44 (600 kcmil), K44 (twin 50 kcmil), or K08 (twin 600 kcmil). Line connectors can be reversed to change from overhead to underground service. Bypass: Lever supplies clamping action on meter spades and also operates bypass device. Bussing: 8 x aluminum bussing is supplied. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
35 Multi-Position Meter Mains 5 Amps 4 Terminal Ringless 0/40 VAC 5 5 AMP MULTI- POSITION METER MAINS U6-X-BL 6 65 NOTE Each unit is supplied with a 5 amp jaw clamping lever bypass block assembly in the far right meter position only. All remaining positions are 5 amp with no bypass Amp Per Position Multi-Position Meter Mains Ringless Catalog Amps Per Line Connector Size Dimensions Knockouts Positions Number Position Line Load D" W" H" U6-X-BL 5 8" x 6 Stud* C.B U64-X-BL 5 4 8" x 6 Stud* C.B U65-X-BL 5 5 8" x 6 Stud* C.B AIC Rating: All models are rated K AIC when used with approved breakers rated at K. Hub: Units supplied with one () closing plate. Order hubs separately, see Accessories page. Fifth Terminal: For a field-mounted fifth terminal, order catalog number K5T for tenant positions, and order K865 for the far right house power lever bypass socket. Manfacturer Cutler Hammer Siemens G.E. (50 Amp Max) Square D 5 Amps or Less BR, HQP, QPGF QP, QPH (K) THQL Homeline Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
36 6 5 & 00 AMP MULTI- POSITION METER MAINS Multi-Position Meter Mains 5 & 00 Amps 4 Terminal Ringless 0/40 VAC U854-X 5 Amp Per Position Multi-Position Sockets Ringless Catalog Number Connector Kits* Amps Per Position Positions Main Bus Rating 00 Amp Per Position Multi-Position Sockets Ringless Line Connector Size U866-X Breaker Chart Dimensions D" W" H" U85-X 5 00 Amp 8" x 6 Stud* U85-X 5 00 Amp 8" x 6 Stud* U854-X Amp 8" x 6 Stud* U855-X Amp 8" x 6 Stud* U856-X Amp 8" x 6 Stud* Catalog Number Size Suffix Kit Number Compatible With Wire Range Single Twin Amps Per Position Positions Main Bus Rating Line Connector Size Dimensions D" W" H" U88-X Amp #6-50 kcmil 4 7 U86-X Amp 8" x 6 Stud* U86-X Amp 8" x 6 Stud* U864-X Amp 8" x 6 Stud* U865-X Amp 8" x 6 Stud* U866-X Amp 8" x 6 Stud* K K59 U85-56, U86-66 #6-50 -K K540 U854-56, U # K K50 U854-56, U86-66 #6-50 -K4 K54 U #-600 Manufacturer Amps 5 Amps or Less Cutler Hammer BJ, WBJ Quicklag P, BR, HQP Siemens QNR QP Murray MD MP G.E. Q Line Square D Homeline Connectors: For line wire connector kits, order separately. Fifth Terminal: For field mounted fifth terminal, order catalog number K8. Order one per meter position. Breakers: Units have provision for one double pole main per meter position. Breakers not included. Short Circuit Current Rating: 0K AIC. However, this rating is limited to the lowest interrupting capacity of any circuit breaker installed. Watthour meter not included in short circuit current rating. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
37 Multi-Position Meter Mains Knockout Information 7 5 & 00 AMP MULTI- POSITION METER MAINS Catalog Number Knockouts 4 U88-X 4, U85-X, U85-X, U854-X, U855-X, U856-X, U86-X, U86-X, U864-X, U865-X, U866-X, Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
38 8 00 AMP LEVER BYPASS MULTI- POSITION METER MAINS Lever Bypass Multi-Position Meter Mains 00 Amps 5 Terminals Ringless 0/40 VAC U474-XT-5T9 00 Amps/Position 5 Terminals Lever Bypass Multi-Position Meter Mains Ringless ØW Catalog Number Positions Main Bus Rating Line Connector Size Dimensions Knockouts D" W" H" U47-XT-5T9 0 Amps 8" x 6 Stud* , U47-XT-5T9 480 Amps 8" x 6 Stud* , U474-XT-5T Amps 8" x 6 Stud* , U475-XT-5T Amps 8" x 6 Stud* , U476-XT-5T Amps 8" x 6 Stud* , Connector Kits* Kit Wire Size Suffix Number Range Single -K K540 # K K50 #6-50 Twin -K4 K54 # Breaker Chart Manufacturer Amps 5 Amps or Less Cutler Hammer BJ, WBJ Quicklag P BR, HQP Siemens (ITE) QNR QP Murray MD MP G.E. Q Line Square D Homeline *Connectors: For line wire connector kits, order separately (see chart above). Breakers: Units have provision for one double pole main per meter position. Breakers not included. Order as extra (see chart above). Bypass: Lever supplies clamping action on meter spades and also operates bypass device. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
39 Plunger Bypass Transformer Rated Sockets 0 Amps 6 Terminals 600 VAC 9 0 AMP TRANSFORMER RATED SOCKETS UC99-XL UC7545-RL 0 Amps Transformer Rated Sockets Catalog Number Type Terminals Meter Form Hub Connectors CU Bypass Dimensions Knockouts D" W" H" 4 UC99-XL Ringless 6 4S C.P. #4-4 Plunger UC7544-RL Ring Type 8 5S H.O. #4-4 Plunger UC7545-RL Ring Type 6, 8, 9S & (ALT) 0S H.O. #4-4 Plunger Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Bypass: Plunger type bypass automatically closes when meter is removed. Connectors: Units are supplied with mechanical type connectors. Sealing Ring: The ring-type UC7544 and UC7545 units include a MR- snap type sealing ring. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
40 40 0 AMP TRANSFORMER RATED SOCKETS Transformer Rated Sockets 0 Amps 6 Terminals 600 VAC U7449-XL 0 Amps Transformer Rated Sockets Piece Cover Catalog Number Terminals Meter Form Hub Connectors CU Bypass Dimensions Knockouts D" W" H" UC75-XL 6 4S C.P. #4-4 Test Switch Provision UC7448-XL 8 5S C.P. #4-4 Test Switch Provision UC7449-XL 6, 8, 9S & (ALT) 0S C.P. #4-4 Test Switch Provision 4 8 0,,, Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Connectors: Supplied with tin plated mechanical connectors (#4 maximum). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
41 Transformer Rated Sockets 0 Amps 6 Terminals 600 VAC 4 0 AMP TRANSFORMER RATED SOCKETS UC7445-O--NOE UC4965-O-WC--NST 0 Amps Transformer Rated Sockets With Pre-wired Test Switch Approved for N.E. Utilities Catalog Number Terminals Meter Form Cover Hub Connectors CU Bypass Dimensions Knockouts D" W" H" UC7478-O-8-NOE 6 4S Piece Blank #4-4 Test Switch UC7444-O-4-NOE 8 5S Piece Blank #4-4 Test Switch UC7445-O--NOE 6, 8, 9S & (ALT) 0S Piece Blank #4-4 Test Switch 4 8 0,,, 0 Amps Transformer Rated Sockets With Prewired Test Switch Approved for NSTAR Catalog Number Terminals Meter Form Cover Hub Connectors CU Bypass Dimensions Knockouts D" W" H" UC4964-O-WC--NST 6 4S Piece Blank #4-4 Test Switch 5 8 0, UC4965-O-WC--NST 8 5S Piece Blank #4-4 Test Switch 5 8 0, 6, 8, 9S & UC4966-O-WC--NST (ALT) 0S Piece Blank #4-4 Test Switch 5 8 0, Hubs: For proper hub selection, see the hub suffix chart on the Accessories page. Connectors: Supplied with tin plated mechanical connectors (#4 maximum). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
42 4 TEST SWITCHES Test Switches 4, 7 & 0 Pole Catalog Number 4-Pole TS04-00 X P Pn X C+ C X TS04-00 X P C+ C X Pn X TS04-00 X P Pn X C C+ X TS X C+ C X P Pn X 4-pole switches are also available on 0-pole bases. Contact Milbank for appropriate catalog numbers. 7 /" /" Catalog Number 7-Pole TS P P Pn C+ C C+ C TS P C+ C P C+ C Pn TS P P Pn C C+ C C+ TS C+ C C+ C P P Pn /" 4-pole switches are also available on 0-pole bases. Contact Milbank for appropriate catalog numbers. P C+ C N Pn X 9 /" Key Potential Switch Line side current switch with short circuit assembly Load side current switch with test jack assembly Neutral bar (no switch) Neutral Potential Switch Unused Position on base Insulating barrier, isolates both sides of switch Catalog Number 7-Pole on a 0-Pole Base TS P X P X Pn X C+ C C C+ TS P X P X Pn X C+ C C+ C TS X P C+ C P C C+ Pn X X TS07-00 P X P X Pn X C C+ C C+ Catalog Number 0-Pole TS0-009 P P P Pn C+ C C+ C C+ C TS0-00 P C+ C P C+ C P C+ C Pn TS0-0 P P P Pn C C+ C C+ C C+ TS0-0 C+ C C+ C C+ C P P P Pn Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
43 Current Transformer Enclosures Amps AMP CURRENT TRANSFORMER ENCLOSURES U855-O-NE Current Transformer Enclosures Catalog Number Amperage Rating Hub Steel Gauge Connectors CU/AL Dimensions D" W" H" U855-O-NE Blank connectors per phase 6 6 U856-O-NE Blank 5 connectors per phase Features: These enclosures have three-point locking handles, lift-off hinges with stainless steel pins and two doors. Type R rated. Connectors: Minimum #4, maximum 600 mcm. U855 and U856 both come from the factory with isolated neutrals. Bonding straps are included but not attached with each 855 and 856 if isolated neutral is not needed. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
44 44 TEST CABINET Test Cabinet With Pre-Drilled Test Switch Bridge 857 S857 Test Cabinet Catalog Number Hub Dimensions Knockouts D" W" H" S857 Blank Features: Test cabinet has a piano-hinged cover and pre-drilled test switch bridge. The top of the enclosure has a rectangular knockout for bussing. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
45 Polyphase Enclosures For A Base Meters 45 POLYPHASE ENCLOSURES S78-FB-XL-C S90-FB-XL-C7 Polyphase Enclosures Catalog Number Number of Positions Hub Dimensions D W H S78-FB-XL-C C.P S90-FB-XL-C7 C.P Features: Units are supplied with full board and one demand reset cover per meter position. Cover holding arms included. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
46 46 UNIVERSAL METER PEDESTAL UNIT Universal Meter Pedestal Unit For Pad Mounting Applications S76-O Penta Bolt locking mechanism Universal Meter Pedestal Units for Pad Mounting Catalog Number Hub Application Service Dimensions Knockouts D" W" H" S76-O Blank Pad mounted pedestal UG " S4098-O Blank See note below UG Direct Burial Kit: Direct burial kit K6 and stabilizer foot K88 are included. Pad mount sleeve K7 must be ordered separately. Connectors: Supplied with tin plated mechanical connectors (#4 maximum). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
47 Meter Main Pedestal 00 Amps 4 Terminals 0/40 VAC AMP METER MAIN PEDESTAL U70-O K6/ K88 Burial kit K7 Pad mount Universal Meter Pedestal Units for Pad Mounting Catalog Number Hub Application Service Dimensions Knockouts D" W" H" U70-O Blank Pad mounted pedestal UG " U77-O Blank See note below UG Direct Burial Kit: Direct burial kit K6 and stabilizer foot K88 are included. Pad mount sleeve K7 must be ordered separately. Connectors: Supplied with tin plated mechanical connectors (#4 maximum). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
48 48 00 AMP METER MAIN W/ LOAD CENTER PEDESTALS Meter Main w/ Load Center Pedestal 00 Amps 4 Terminals Lever Bypass 0/40 VAC 4 /8" 55" 5 /" 9 7/8" " Stabilizer Foot " 4 4 U4-O-BL U4-O-BL 00 Amps 4 Terminals Meter Main Pedestals Lever Bypass Ringless Catalog Number Meter Connectors CU/AL Circuit Knockouts Dimensions Bypass Positions Line Load Provisions D" W" H" U4-O-BL Single Lever Twin #6-50 CB U4-O-BL Double Lever Twin #6-50 CB Lever Bypass: Lever provides clamping action on meter spades and also operates bypass device Application: The U4 & U4 pedestals are suitable for use as service equipment or mobile home service equipment. K508/K88 for direct burial application is included with unit. K55 for pad mount application must be ordered as extra. Breakers: These units are wired as parallel mains and have provisions for six circuits: 6 single-pole or double-pole breakers. Short Circuit Current Rating: 0K AIC. However, this rating is limited to the lowest interrupting capacity of any circuit breaker installed. Watthour meter not included in short circuit current rating. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
49 Temporary Power Units 5 Amp 4 Terminal Ringless 0/40 VAC 49 5 AMP TEMPORARY POWER UNITS U50-XL-GR U4908-O-GR 4 Terminal Temporary Power Units Ringless ØW Catalog Number Amps Service Hub Connectors CU/AL Dimensions Knockouts Line Load D" W" H" 4 5 U50-XL-GR* 5 OH C.P. #6-50 CB U4908-O-GR* 5 UG Blank #6-/0 CB Interior: Six circuit plated copper interior accepts standard plug-in type circuit breakers. Receptacle Bridge: Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates. Included Parts: U4908 and U50 come supplied with -0 amp single pole breakers and -0 amp GFCI receptacles (pre-wired and installed). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
50 50 CIRCUIT BREAKERS Circuit Breakers UQFP Plug-In & UQFB Bolt-On Series 0/40 VAC UQFP UQFPH UQFP-M UQFPH-M UQFB-X UQFBH 00 Amp Frame Plug-In 0,000 AIC &,000 AIC Two-Pole Common Trip Amps 0K AIC Plug-In K AIC Plug-In 0K AIC Plug-In K AIC Plug-In Wire Range 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 #-# #-/0 5 UQFP-5 UQFPH-5 UQFP-M-5 UQFPH-M-5 #-# #-/0 50 UQFP-50 UQFPH-50 UQFP-M-50 UQFPH-M-50 /0-00 / UQFP-75 UQFPH-75 UQFP-M-75 UQFPH-M-75 /0-00 / UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 /0-00 / Amp Frame Bolt-On 0,000 AIC &,000 AIC Two-Pole Common Trip Amps 0K AIC Bolt-On K AIC Bolt-On 0K AIC Bolt-On K AIC Bolt-On CU Wire Range 00 UQFB-00 UQFBH-00 UQFB-00-X UQFBH-M-00 #-# #-/0 5 UQFB-5 UQFBH-5 UQFB-5-X UQFBH-M-5 #-# #-/0 50 UQFB-50 UQFBH-50 UQFB-50-X UQFBH-M-50 /0-00 / UQFB-75 UQFBH-75 UQFB-75-X UQFBH-M-75 /0-00 / UQFB-00 UQFBH-00 UQFB-00-X UQFBH-M-00 /0-00 /0-00 UL Listed: For use with 60 C or 75 C wire. UQFP: For parallel main circuit breaker applications. UQFP-M: For series main circuit breaker applications Split load tab features allow for feed-through capability. UQFB: () /0-00 lugs provided on load and line side (cable-in, cable-out). UQFB: Three-pole available. Consult factory. UQFB-X: () /0-00 lugs provided on load side and () line bar bus connections on line side. UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed-through capability. CU AL AL Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
51 Circuit Breakers QP (small frame) and QN (large frame) 0/40 VAC 5 CIRCUIT BREAKERS 5 5 Amp Breaker Plug-In Type Per Pole Amps Poles 0K AIC Plug-In K AIC Plug-In 5 Single Q5 Q5H 5 Double Q5 Q5H 0 Single Q0 Q0H 0 Double Q0 Q0H 5 Single Q5 Q5H 5 Double Q5 Q5H 0 Single Q0 Q0H 0 Double Q0 Q0H 5 Single Q5 Q5H 5 Double Q5 Q5H 40 Single Q40 Q40H 40 Double Q40 Q40H 50 Single Q50 Q50H 50 Double Q50 Q50H 60 Single Q60 Q60H 60 Double Q60 Q60H 70 Single Q70 Q70H 70 Double Q70 Q70H 80 Double Q80 Q80H 90 Double Q90 Q90H 00 Double Q00 Q00H 5 Double Q5 Q5H QN00H WBJ00 QN00RH Q50 00 Amp Frame Plug-In 0,000 AIC &,000 AIC Two-Pole, Common Trip Amps 0K AIC Plug-In K AIC Plug-In Handle Location Wire Range CU AL 50 QN50 QN50H Left facing #4-00 # QN00 QN00H Left facing #4-00 # QN50R QN50RH Right facing #4-00 # QN00R QN00RH Right facing #4-00 # WBJ50 Centered #-00 # WBJ00 Centered #-00 #-00 Load connectors supplied with breakers. UL Listed for use with 60 C or 75 C wire. Wire sizes shown are lug capacity. Consult NEC Article #0 for specific wire sizes. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
52 5 Accessories ACCESSORIES Hubs and Closing Plates -RL Small hub opening -WL A754 -YL A755 -ZL A756 -DL A757 -EL A758 -XL A755 " hub " hub " hub " hub " hub Small closing plate -R Large hub opening -F A80 -G A8 -H A8 -X A9064 -RRL S84 " hub " hub 4" hub Large closing plate Large hub opening adapted to small hub oepning Suffix: Add to catalog number for factory installation of hub. Packaging: Individually packed units for field installation. Abbreviations: H.O. (hub opening), C.P. (closing plate). Hub Mast rated Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
53 Accessories Connector Kits, Closing Kits & Generator Interlock 5 ACCESSORIES Connector Kits For Use with 8"-6 Stud Type Units Only Bypass Link Single Twin Suffix Part # ( per set) - Ø Suffix Part # ( per set) - Ø K K K K K K or () /0-50* KL K50L 6-50 (non rotating) KL K540L or () /0-50* (non rotating) K4 K Suffix Part # (4 per set) - Ø Suffix Part # (4 per set) - Ø K5 K K6 K K7 K or () /0-50* K8 K K880 (sold in pairs) Note Consult factory for proper connector kits for studded meter sockets. *For () /0-50, conductors must be of same size. Closing Covers Disconnect Sleeve Isolated Neutral Kit Meter Closing Plate (Ring Type / Ringless) Metal Closing Plate (For Ringless Sockets) Grey Plastic CP Clear Plastic Clear Plastic M5-44 Do not use with lever bypass sockets K047 Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
54 54 Accessories ACCESSORIES Fifth Terminals, Tap Connectors & Block Assemblies Fifth Terminals 5T8K Amp Plug-In K5T - 00 Amp (Block with Square Hole) K865 - Heavy Duty Jaw Clamping (K866 without Neutral Wire) K56 Tap Connectors ( per set) K4977-INT - Internal Hex K4977-EXT - External Hex K50-INT - Internal Hex (set of 4 w/ barrier) Replaces the load or line side slide-in nut assembly on Milbank 00 amp sockets. Allows for a 00 amp tap location in addition to the #6-50 kcmil load-side connector. K50 includes safety barrier extensions for applications over 00 VAC. Three lugs per kit. Triplex Ground K90 (For factory installed triplex ground, add suffix -TG to catalog number) 00 Amp Blocks (single sockets only) 00 Amp Blocks (single sockets only) BL Block Assembly Z AO - Slotted Nut Assembly Z80965-AC - Neutral without Nut Z9095-AC - Hex Nut Set Screw K457 - Internal Hex Block Assembly (w/ meter support) K458 - External Hex Block Assembly (w/ meter support) Z9665-AO - Internal Nut Assembly Z9664-AO - External Nut Assembly Z84898-AC - Neutral without Nut Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
55 Commercial Pedestals Attractive Easy to Install Secure Cost-Effective 55 COMMERCIAL PEDESTALS Milbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly, costly and inefficient strut and backboard structures. Strut and backboard Commercial pedestal UL-listed as Industrial Control Equipment (File E855) Standard Features Type R rainproof, vandal-resistant cabinet of polyurethane powder-coated steel (aluminum or stainless steel also available) UL-listed as enclosed industrial control equipment (UL508) Isolated lockable and sealable utility metering and lug landing sections Lockable customer section for distribution and control equipment with internal deadfront Print pocket inside customer section door contains wiring schematics and installation instructions Most load centers are UL-listed for use with various manufacturers circuit breakers All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws) Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
56 56 COMMERCIAL PEDESTALS Commercial Pedestals Attractive Easy to Install Secure Cost-Effective These units are ideal for controlling and metering: Traffic signals Street lighting Irrigation and sprinkler systems Cell towers and telephone vaults Pump stations Temporary power for fairgrounds, swap meets, outdoor markets, portable offices, holiday lights, etc. Outdoor lighting for athletic fields, tennis and basketball courts, parking lots, landscaping and subdivision entrances, etc. Available Factory-Installed Options Meter sockets: ring type or ringless, up to 400 amp Main and branch breakers or T fuses Distribution: copper load centers and panel boards Clocks, timers and relays Photoelectric cells and controls Power receptacles: pin and sleeve, twist lock or straight blade Contactors: definite purpose, electrical or mechanically held, IEC and mercury types Surge protection and lightning arrestors Reserve inlet generator receptacle with interlocked circuit breakers Motor starters and relays Push button controls Thermostat controls, fans and heating strips Power blocks and terminal blocks Steel, aluminum and plywood backboards Transformers Interlock devices for circuit breakers Available in steel, aluminum (unpainted, painted or anodized) or stainless steel construction with powder-coated finish available in eight standard colors or special-ordered RAL colors Available for applications up to 400 amp, 0V, 08V, 40V, 77V, 480V - Ø or Ø Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
57 Generators Home Standby, Commercial & Industrial and Portable 57 GENERATORS Home Standby Generators 8-0kW Air-cooled 5-6kW Liquid-cooled SynapSwitch TM Transfer Switches Amp Vigilant TM Amp MTS 0-50 Amp Commercial/Industrial Generators 80-50kW Gaseous 0-400kW Diesel Portable Generators -.8kW Digital Inverter.-0kW Portable Generator Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
58 58 SynapSwitch TM TRANSFER SWITCHES Automatic Transfer Switch Milbank is proud to introduce the new SynapSwitch TM Automatic Transfer Switch (ATS). Compatible with our 8-6kW home standby generators, the SynapSwitch TM will immediately signal your generator to start up in the event of a power outage - so when the power goes out, you won t be left in the dark. FEATURES Load Management - The SynapSwitch TM can manage up to two electrical loads, or six when paired with remote modules, enabling you to receive whole-house power from a smaller generator. Intelligent Synap Technology - This switch uses state-ofthe-art technology that constantly measures power and frequency allowing the switch to predict and react to changes in demand, as well as prevent the generator from overloading. Load Priority - The switch intelligently selects managed loads based on priority or load size. LED Status Indicator - The indicator shows whether load is under utility or generated power and indicates which managed loads are on or off. Certified to FCC Chapter 5 Part B - The ATS adheres to the strictest code for electronic design to avoid interference with radio and Wi-Fi signals. Generator Disconnect - The disconnect allows the generator to be quickly taken out of service in the event of emergency shutoff. NEMA R Cabinet - This durable enclosure is suitable for indoor or outdoor installations. Adaptability - The intelligent switch automatically adapts to seasonal changes of the loads. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
59 Watthour Meter Forms Standard Forms Transformer Rated or Self-Contained 59 WATTHOUR METER FORMS SC SC TR TR TR and -WIRE FORMS S & S and -WIRE FORMS S & S with BYPASS -WIRE FORM S 5th Term. 9 o'clock -WIRE FORM S with BYPASS -WIRE FORM S 5th Term.6 o'clock TR SC SC SC SC -WIRE FORM S with BYPASS ELEMENT -WIRE NETWORK FORM S 5th TERM. 9 o'clock ELEMENT -WIRE NETWORK FORM S with BYPASS 5th Term. 9 o'clock ELEMENT -WIRE NETWORK FORM S 5th TERM. 6 o'clock ELEMENT -WIRE NETWORK FORM S with BYPASS 5th Term. 6 o'clock TR TR SC SC TR -WIRE FORM 4S -WIRE FORM 4S WITH BYPASS or ELEMENT 4W Y or Y FORM 4S FORM 5S Y FORM 6S or ELEMENT 4W Y or FORMS 4S & 5S with BYPASS ELEMENT 4W Y or Y FORM 7S FORM 4S with BYPASS TR TR SC SC TR ELEMENT W, 4W, W FORM 5S ELEMENT W, 4W, W FORM 5S with BYPASS ELEMENT W, 4W, W FORM S or ELEMENT W, 4W, W FORM S with BYPASS or ELEMENT 4W Y or Y FORM 9S FORM 8S TR = TRANSFORMER RATED SC = SELF CONTAINED TR TR TR or ELEMENT 4W Y or FORMS 8S & 9S with BYPASS ELEMENT 4W Y FORM 6S ELEMENT 4W Y FORM 6S with BYPASS Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
60 60 Meter Forms METER FORMS Reference Information DIAGRAM A W with P.T. & C.T. Single Stator Meter(W ) - Form S 5T Socket, Test Switch #TS04-00 DIAGRAM B W with C.T. Single Stator Meter (W ) - Form S 5T Socket, Test Switch #TS04-00 DIAGRAM C W with C.T. s Single Stator Meter (W ) - Form 4S 6T Socket, Test Switch #TS DIAGRAM D W or W Network with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM A DIAGRAM B DIAGRAM C DIAGRAM D (ALT.LOC.) (ALT.LOC.) P PN C + C P PN C + C P P C + C + C + C P P C + PN C C + C + P.T. + I LINE N (BONDED) + + C.T. LOAD I LINE N (BONDED) + C.T. + LOAD I LINE N (BONDED) + + C.T. + + C.T. LOAD I LINE N (BONDED) + + C.T. + + C.T. LOAD DIAGRAM E W with P.T. s & C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM F W with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM G 4W Y with C.T. s Stator Meter - Form 6S T Socket, Test Switch #TS0-009 DIAGRAM H 4W Y with P.T. s & C.T. s Stator Meter - Form 6S T Socket, Test Switch #TS0-009 DIAGRAM E DIAGRAM F DIAGRAM G DIAGRAM H P P PN C+ C C + C C + C P P PN C+ C C+ C C+ C P P P C + C C + C P C + P P C C + C + + LINE PT PT C.T. + + C.T. LOAD LINE + + C.T. + + C.T. LOAD LINE N (BONDED) C.T. + LOAD C.T. + + C.T. PT PT + + LINE N (BONDED) C.T. + LOAD C.T. + + C.T. DIAGRAM I 4W Y or with C.T. s Y Stator Meter - Form 9S Stator Meter - Form 8S T Socket, Test Switch #TS0-009 P P P PN C + DIAGRAM I C C + C C + C DIAGRAM J 4W Y with P.T. s & C.T. s Stator Meter - Form 9S T Socket, Test Switch #TS0-009 P DIAGRAM J P PN C+ P C C + C C+ C Prewiring: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. LINE N (BONDED) C.T. + LOAD C.T. + + C.T. PT PT PT LINE N (BONDED) C.T. + + LOAD C.T. + C.T. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
61 Conduit, Ampacity & SCCR Reference Information 6 CONDUIT, AMPACITY & SCCR MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT Table from 008 NEC Code Reference: Rigid Metal Conduit Type THHN, THWN, THWN- XHH, XHHW, XHHW- Conductor Size (AWG/kcmil) Conduit Trade Sizes (Inches) / / / / / / / This table is for concentric stranded conductors only. For cables with compact conductors refer to NEC. Refer to latest NEC Code or Local Codes for updated requirements. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com
Wisconsin Area Catalog
Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationIndiana Meter Mounting Equipment
Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationREC Municipal Meter Mounting Equipment
REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationDuke/MEG Approval Meter Equipment Group
Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides
More informationOhio Meter Mounting Equipment
Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures
More informationMEG Approval Meter Equipment Group
MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationComEd Service Area Meter Mounting Equipment
ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs
More informationMeter Mounting Equipment Wisconsin Area
Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At
More informationLouisiana/Mississippi. Area Catalog
Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationNew Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment
New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work
More informationPennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog
Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationMeter Mounting Equipment DTE Energy Area
Meter Mounting Equipment DTE Energy Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationTennessee Area Meter Mounting Equipment
Tennessee Area Meter Mounting Equipment MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationLouisiana & Mississippi Area Catalog
Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.483.534 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy
More informationMeter Mounting Equipment. Northern Indiana Public Service Co.
Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop
More informationMeter Mounting Equipment. GA/AL/FL Panhandle Area
Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke
More informationMeter Mounting Equipment Florida Area Catalog
Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert
More informationUpstate New York Meter Mounting Equipment
Upstate New York Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIE Milbank Overview Energy At ork since 97 Milbank builds
More informationMeter Mounting Equipment Commonwealth Edison
Meter Mounting Equipment Commonwealth Edison MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice
More informationInstrument Rated Metering Equipment
Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions
More informationMeter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market
Meter Mounting Equipment Arkansas, W. Tennessee, N. Mississippi Market MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman
More informationMeter Mounting Equipment Colorado Area
Meter Mounting Equipment Colorado Area milbank overview milbank overview Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. aldrop, 9-00 Robert F. aldrop, II Chairman Katrina aldrop Henke Vice Chairman
More informationMeter Mounting Equipment Colorado Area
Meter Mounting Equipment Colorado Area U80 PROFILE U8 Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements
More informationConsolidated Edison Orange & Rockland Meter Mounting Equipment
Consolidated Edison Orange & Rockland Meter Mounting Equipment 2 MILBANK OVERVIE Milbank Overview Energy At ork since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationMeter Mounting Equipment
Meter Mounting Equipment Central Hudson Service Area New York State Electric & Gas Service Area National Grid NY Service Area Rochester Gas & Electric Service Area MILBANK OVERVIEW MILBANK OVERVIEW Charles
More informationPSE&G Long Island Meter Mounting Equipment
PSE&G Long Island Meter Mounting Equipment Milbank Overview Energy At Work since 927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential,
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationtot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,
' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *
More informationGroup Meter Main - Without Bypass
100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included
More information(CT, NH, ME, RI, VT, MA)
Selection and application guide For use in New England States (CT, NH, ME, RI, VT, MA) Meter Mounting Equipment www.talonmetering.com 1 Meter Mounting Equipment Table of Contents Service Rating Positions
More informationCT Metering. CT Metering. Meter Mounting Equipment
Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationCP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long
More informationMultiple Metering, Horizontal Gang - Non Lever Bypass
Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground
More informationMetering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering
Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal
More informationRMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities
RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationSupplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT
Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT 2011 81 APPENDIX A: APPROVED METERING EQUIPMENT TABLE OF CONTENTS Approved Metering Equipment... A-1
More informationModular Metering Construction Details
GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationMultiple Metering, Vertical Gang
Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationEquipment. Metering. Metering Equipment 1. Contents
1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationSelection and Application Guide. Meter Mounting Equipment. For use in Iowa and Nebraska.
Selection and Application Guide Meter Mounting Equipment For use in Iowa and Nebraska www.talonmetering.com Meter Mounting Equipment Table of Contents Air Conditioning Disconnects Fused and Non-fused Rating
More informationCurrent Transformer, Termination & Disconnect Cabinets WE Energies Approved
Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More informationMP Meter-Pak Meter Centers
Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationEquipment. Metering. Metering Equipment 1. Contents
1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................
More informationModular Metering Application Guide
GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III
More informationSelection and Application Guide For use in New England EQUIPMENT
Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,
More informationSelection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting
Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,
More informationClass 320 Metering. Class 320 Metering. Meter Mounting Equipment
Single Meter Sockets, Without ypass -............................ 57-58 Meter Mains, With Optional MCC ypass -......................... 59-60 Meter Main Load Centers, With Optional MCC ypass -..........
More informationSelection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting
Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationCommercial & Industrial Product Catalog
Commercial & Industrial Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More informationTemporary Power Outlet Panels
Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order
More informationMeter Centers Meter Mounting Devices
Meter Mounting Devices General General Information Materials: 16 gauge, galvanized steel, G-90 Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless
More information5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets
.1 Metering Products Product Description Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac All Eaton sockets are rated All single meter sockets are 600 Vac maximum and either UL labeled and are
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationCommercial Pedestals Product Catalog
Commercial Pedestals Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
More informationWPS SERVICE MANUAL. Section Amp and Smaller - Common
Revised 01/2017 Section 2 200 AMP AND SMALLER - COMMON Page 1 of 17 Section 2 200 Amp and Smaller - Common 2-0 General Metering Requirements... 2 2-1 Basic Calculations... 4 2-2 100-200 Amp Single-Phase
More informationSPEEDFAX TM 2011 Meter Centers Contents
SPEEDFAX TM 011 Meter Centers Contents Single and Multiple s - -19 General Information - -3 Single Position s - Residential Types -4-5 Multiple Position s Residential Types -6-7 Single Position s Commercial
More informationCommercial Pedestals Product Catalog
Commercial Pedestals Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank provides the tools that empower life. We enable the amazing in countless everyday ways through
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More informationPower Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module
Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module
More informationMeter Mains - Without Bypass
- 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat
More informationSECTION 500 METERING AND ASSOCIATED EQUIPMENT
SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.
More informationSingle Socket and Horizontal Metering
Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase
More informationSelection and application guide. For use in Kansas, Iowa, Missouri and Illinois. Meter mounting equipment.
Selection and application guide For use in Kansas, Iowa, Missouri and Illinois Meter mounting equipment www.landisandgyr.com Contents Service Rating Positions Terminals Page Introduction and General Information
More informationSelection and application guide. For use in Texas. Meter Mounting Equipment.
Selection and application guide For use in Texas Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and General
More informationMicrolectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units
Microlectric CO Series Meter sockets A complete family of combination meter sockets and breaker units Outdoor, above-ground main breaker access increases safety Table of Contents Introduction... 3 Microlectric
More informationCustomer Requirements Meter Socket Configurations
Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements
More informationSingle Socket and Horizontal Metering
G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal
DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)
More informationLoadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application
Product Offering and Specificaton Guide Application Main lug loadcentre, b Phase 3 W /V, to 0A, / - 0/80 circuits b 3 Phase W /8V, 00 to 5A, - circuits Main Breaker loadcentre, b Phase 3 W /V, to 0A, /
More information6.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationPower Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................
More informationSelection and application guide
Selection and application guide For use in Louisiana and Mississippi Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction
More informationMeter Centers & Loadcenters Group Metering
June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through
More informationContents. 4 Loadcentres
POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ
More informationPower Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................
More informationOptions: PART NUMBER MAIN BREAKER PHASE VOLTAGE
BC Hydro Metering Kiosk BCH Metering and distribution kiosk built to BC Hydro distribution standards. Used for applications where secondary services are installed in weatherproof kiosks outside of a main
More informationSPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents
SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 WireGuide Load Centers and Breakers -4 PL Series Load Centers Features
More informationElectric Service Equipment
2018 Electric Service Equipment METER SOCKETS CABINETS ENCLOSURES 2017 Alliant Energy 885246 9/17 JS Updates to this manual may be necessary throughout the year. Please see www.alliantenergy.com/servicemanuals
More informationVolume 1 Residential and Light Commercial CA E December
Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application
More information