Meter Mounting Equipment Colorado Area

Size: px
Start display at page:

Download "Meter Mounting Equipment Colorado Area"

Transcription

1 Meter Mounting Equipment Colorado Area

2 milbank overview milbank overview Charles A. Milbank Bill Martin Robert F. aldrop, 9-00 Robert F. aldrop, II Chairman Katrina aldrop Henke Vice Chairman Milbank Quality Metering Products for 80 Years Milbank Manufacturing Company was established in 97 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 94 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturer s representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbank s employee base of over,000 workers, along with our five manufacturing facilities comprising almost 550,000 square feet give us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 0,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Service Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs, and related accessories. If you don t find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is an important factor to remain competitive in today s electrical market. Milbank has been serving the electric utility & wholesale distribution industries for 80 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the past with dependable service and quality products! e take great pride in being one of the few family-owned businesses left in our industry. e are a third generation run business and truly believe that... Family makes a difference!

3 product index by category Catalog Number Logic Disconnects (0-00 Amp) 0 & 0 Amp Fusible/Non-Fusible AC Disconnects AC Disconnect with FCI Protection/SPA Box Single Position 5/00 Amp - 4 & 5 Terminal - Ringless - 00 VAC Amp - 4 & 5 Terminal-Ringless/Ring Type-00 VAC Amp - 4 Terminal - Jaw Clamping Lever - Ringless-00 VAC Amp - 4, 5 & 7 Terminal - Heavy Duty Lever Bypass - Ringless - 00 VAC Amp - 5 & 7 Terminal - Ringless - 00 VAC Amp Continuous - 4 & 7 Terminal - Heavy Duty Lever Bypass - 00 VAC Amp - 4 & 5 Terminal - Heavy Duty - Ringless - 00 VAC product index by category Multiple Position 00 Amp - 4 Terminal - Horizonal angs - Ringless Amp - Condominium Metering Banks - 4 Terminal - Ø - 0/40 VAC Amp - Condominium Metering Banks - Lever Bypass - 0/40 VAC Meter Mains 00/50/00 Amp - 4 Terminal - 00 VAC - Meter Main /00 Amp - Ringless Meter Mains - 5 Terminal - K AIC Amp - Meter Socket/Load Center - 4 Terminal - Ringless Amp - 4 Terminal - Ringless - Meter Main with Side ireway CT Rated 0 Amp - 5,, 8,, & 5 Terminal - 00 VAC - Current Transformer - Test Switch Provision Test Switches - 4, 7, & 0 Pole - 00 VAC - Per ANSI C.9 Standard Milbank Test Switch orksheet Service Pedestals 00 Amp - 4 Terminal - Service Entrance Pedestal - Lever Bypass Ringless - 0/40 VAC Amp - Series U570 & U570 Ringless Metered Pedestals Amp - Series U5 & U57 Ringless Metered Pedestals Amp Series Ringless Metered Pedestals Ordering Information Power Outlets 5 Amp - 5 Terminal - Ringless - Jaw Clamping Lever - Metered Power Outlet Commercial Pedestals Commercial Meter Pedestals Overview Applications & Accessories Miscellaneous Accessories UQFP Plug-In Series Circuit Breakers UQFB Bolt-On Series Circuit Breakers Conduit & Ampacity Information Energization of Electrical Equipment Materials and Finishes Meter Forms atthour Meter Forms-Standard Forms-Transormer Rated or Self-Contained Standard NEMA Configurations Utility Index Product Index Additional Milbank Products

4 catalog number logic catalog number logic

5 0 & 0 amp fusible / non-fusible air conditioner disconnects 4 U80 profile U8 Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and, also, complies with article in the NEC. To ensure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of 90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish. 0 & 0 amp fusible / non-fusible air conditioner disconnects TECHNICAL INFORMATION LINE & LOAD CONNECTOR ROUND CONNECTOR IRE CATALO MA T. DIMENSIONS AMP TYPE IRE RANE IRE RANE RATIN CU AL CU/AL D" " H" CU C AL C 0 NONFUSIBLE U #4-# A #-# A #4-4 A /75 0 /75 0 FUSIBLE U8.5 #4-# A #4-# A #4- A / FUSIBLE U80 0. #4-# A #4-# A #4- A /75 0 /75 P UL Listed as Enclosed Pullout Switch. P Ø, 40 VAC. P Type R Rainproof P One-inch concentric knockouts 4

6 5 AC disconnect / spa box AC DisconnecT / SPA BO Combination AC Disconnect / 0 Amp FCI Receptacle Together in Box U8-0R 0 amp, Non-Fused AC Disconnect Duplex 0 amp FCI Receptacle R-TR Type R Enclosure with In-Use Cover Meets NEC # 0. Requirements* UL Listed as Power Outlet Type R Enclosure In-Use Cover** Duplex round Connector Concentric Knockouts AC DISCONNECT Ø, 40 Volt 0 amp, Non-Fused FCI RECEPTACLE 0 amp Reset/Test Button eather Resistant/Tamper Resistant Meets NEC #40.8 Requirements * NEC #0. Heating, Air- Conditioning and Refrigeration Equipment Outlet. The receptacle shall be located on the same level and within 7.5 m (5 ft.) of the heating, airconditioning and refrigeration equipment. * NEC #0.8 round-fault Circuit Interruptor protection for personnel. * NEC #40.8 receptacles in damp or wet conditions AMP TYPE CATALO MA H.P. # AC DISCONNECT IRE RANE ROUND CONNECTOR IRE RANE CU AL CU/AL DIMENSIONS D" " H" IRE RATIN CU C AL C 0 NONFUSIBLE U8-0R 0 #4-# A #-# A #4-#4 A /75 0 /75 To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position. All units are designed with a padlock provision on the cover for security. **Note: U8-0R cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle). *Reprinted with permission from NFPA 70-00, National Electrical Code, Copyright 00, National Fire Protection Association, Quincy, MA 09. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, MA. Hot Tub Disconnect or Sub Panel Breaker Enclosure Type R Spa Box with FCI Protection 40 volt ground fault protection UL listed, Type R rainproof Milbank reliability Easy installation pole, 50 or 0 amp FCI breaker protection Compact size: 8-/ H x 7-/ x -/4 D or 4 wire installation Ø, 0 / 40 VAC Standard package of extra one-pole breaker spaces 00 amp overall rating Sub Panel Breaker Enclosure Use as a 00 amp, 4 circuit sub panel enclosure AMP TYPE CATALO # LINE CONNECTOR IRE RANE CU AL ROUND CONNECTOR IRE RANE CU/AL DIMENSIONS D" " H" 50 BREAKER U488-O-50B 8 #4-/0 #4-/0 #4-/ BREAKER U488-O-0B 8 #4-/0 #4-/0 #4-/

7 5 / 00 AMP 4 & 5 TERMINAL single position ringless 00 VAC U8750-RL-KK u7487-rl-tg-kk U90-RL-KK 5 / 00 AMP 4 & 5 terminal single position ringless 00 VAC amp 4 & 5 terminal ringless TERM SERVICE CATALO HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' OH/U U7487-RL-T-KK H.O. #-/0 #-/0 HORN OH U8750-RL-KK H.O. #-/0 #-/0 HORN amp 5 terminal RESIDENTIAL ringless SERVICE CATALO HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U90-RL-T-KK H.O. #-50 #-50 HORN , 4 FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K for 5 amp unit. bypass: Horn type bypass is provided.

8 7 00 amp 4 & 5 terminal Single position ringless / ring type 00 VAC 00 amp 4 & 5 terminal Single position ringless / ring type 00 VAC U59-O SERVICE amp single position 4 terminal ringless CATALO HUB U405-O CONNECTORS CU/AL DIMENSIONS 4 5 FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 o clock position. HUBS: For proper hub selection see the hub suffix chart on accessory page. CONNECTORS: Extruded aluminum connectors are tin plated CONCENTRIC KO'S D'' '' H'' 4 5 U U57-L C.P. # , amp SINLE POSITION 4 terminal side wireway ringless SERVICE CATALO HUB CONNECTORS CU/AL LINE LOAD DIMENSIONS CONCENTRIC KO'S D'' '' H'' 4 5 U U59-O BLANK 8- STUDS # , 00 amp SINLE POSITION 4 terminal ring TYPE SERVICE CATALO HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S D'' '' H'' 4 5 U U405-O BLANK # , FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 o clock position. HUBS: For proper hub selection see the hub suffix chart on the accessory page. CONNECTORS: Extruded aluminum connectors are tin plated. Sealing Rings: The above ring type units are supplied with an mr-4 screw type sealing ring as standard. 7

9 00 amp 4 terminal JA clamping lever ringlelss 00 VAC amp 4 terminal JA clamping lever ringlelss 00 VAC u985-rrl 00 amp single position 4 terminal ringless Øw SERVICE CATALO HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U985-RRL H.O. 8 x STUD 8 x STUD LEVER , fifth terminal: For field installed fifth terminal order catalog number K8. May be installed in o clock or 9 o clock position. hubs: For proper hub selection refer to the hub suffix chart on the Accessory page. lever bypass: Lever supplies clamping action on meter spades and also operates bypass device. Connectors: Socket is supplied with /8 - hex head nuts with Belleville washers. For connector lug kits, order as extra from chart on page 0. Separate lug kits are required for line and load. 8

10 9 00 amp 4 5, & 7 terminal heavy duty lever Bypass 00 vac 00 amp 4, 5 & 7 terminal heavy duty lever Bypass 00 vac u980-rl SERVICE CATALO HUB u955-rrl U970-RL 00 amp 4 terminal ringless øw fifth terminal: For field mounted fifth terminal, order as extra K8. bypass: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units are supplied with extruded aluminum connectors and bonded neutral with a grounding stud CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U980-RL C.P. #-50 #-50 LEVER , amp 5 terminal ringless øw or øw SERVICE CATALO HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U955-RRL H.O. #-50 #-50 LEVER , HUBS: For proper hub selection see the hub suffix chart on the accessory page. bypass: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units supplied with extruded aluminum connectors, a bonded neutral and a grounding stud. fifth terminal: Fifth terminal is supplied in the o clock position. Fifth terminal can be changed in the field from o clock to 9 o clock position. 00 amp 7 terminal ringless ø4w SERVICE CATALO HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U970-RL C.P. #-50 kcmil #-50 kcmil LEVER , HUBS: For proper hub selection see the hub suffix chart on the accessory page. bypass: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex ground. insulated neutral: For field installed insulated neutral, order kit number K047. 9

11 00 amp 5 & 7 Terminal ringless 00 VAC 0 u480-xl-5t amp 5 & 7 Terminal ringless 00 VAC u455-rrl u470-rrl 00 amp 5 & 7 terminal ringless Ø or Øw TERM SERVICE CATALO HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' OH/U U480-L-5T9 C.P. #-50 #-50 LEVER , 5 OH/U U455-RRL H.O. #-50 #-50 LEVER , 7 OH/U U470-RRL H.O. #-50 #-50 LEVER , HUBS: For proper hub selection see the hub suffix chart on the accessory page. bypass: Lever bypass and the lever supplies clamping action on jaws. factory-installed fifth terminal: Includes factory installed fifth terminal in the 9 o clock position. 0

12 0 amp continuous 4 & 7 terminal heavy duty lever bypass 00 vac 0 amp continuous 4 & 7 terminal heavy duty lever bypass 00 vac u448-x amp 4 & 7 terminal side wireway ringless oh/ug TERMS CATALO PHASE HUB CONNECTORS CU/AL LINE & LOAD FIFTH TERM KITS BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' U448- Ø C.P. 8"- STUD K85 LEVER U594- Ø4 C.P. 8"- STUD LEVER HUBS: For proper hub selection see the hub suffix chart on the accessory page. bypass: The lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Stud type units supplied with /8 - hex head nuts with Belleville washers. For connector kits, order as extra: K59 (50 kcmil) or K540 (00 kcmil). For twin lug connectors order as extra: K50 (50 kcmil). For connector kits, order as extra: k08 (50 kcmil) or k44 (00 kcmil). For twin lug connectors, order as extra: k44 (#4-00 kcmil or () /0-50 kcmil). Separate kits are required for both line and load. Fifth terminal: Fifth terminal is available for field install.

13 0 amp 4 & 5 terminal HEAVY DUTY ringless 00 vac amp 4 & 5 terminal HEAVY DUTY ringless 00 vac u000-o-5t9-kl-kl KO right side only u779-rrl TERM SERVICE 0 amp continuous 4 & 5 terminal heavy duty ringless 00 vac CATALO HUB CONNECTORS CU/AL LINE LOAD #4-00 () /0-50 () #4-00 () /0-50 () #4-00 () TIN /0-50 () #-50 BYPASS DIMENSIONS HUBS: For proper hub selection see the hub suffix chart on the accessory page. bypass: The lever supplies clamping action and also operates bypass device. Fifth terminal: For field installed fifth terminal, order as extra K85. factory-installed fifth terminal: Includes factory installed fifth terminal in the 9 o clock position. CONCENTRIC KO'S D'' '' H'' OH U779-RRL-5T9-K-K H.O. () #-50 LEVER U U000-O-5T9-KL-KL BLANK () #-50 LEVER , 4 U U797-O-KL-KL BLANK LEVER , 4,

14 00 amp 4 terminal horizontal gangs ringless 00 vac 00 amp 4 terminal horizontal gangs ringless 00 vac U5-x-k amp / position 4 terminal ringless # OF POS. SERVICE CATALO HUB CONNECTORS CU/AL LINE LOAD DIMENSIONS CONCENTRIC KO'S D'' '' H'' 4 5 OH/U U5--K C.P. #-50 # OH/U U5--K C.P. #4-00 # () 4 4 U U54--K C.P #4-00 # (4) 4 5 U U55--K4 C.P () #-00 # (5) 4 U U5--K4 C.P () #-00 # () 4 HUB: For proper hub selection, refer to the hub suffix chart on the accessories page. For the U54- two hub openings are supplied and the extra opening is closed with a closing plate as standard. Fifth terminal: For field mounted fifth terminal for U5-, order catalog number K5T (9 o'clock position). CONNECTORS: Extruded aluminum connectors are tin plated. bussing: Bussing is 5/" x " aluminum on the U5-5. On the U54- gangs, the bussing is /8" x " aluminum.

15 5 AMP condominium metering banks 4 TERMINAL ø 0 / 40 VAC 4 # OF POS. CATALO u854-x-hsp (Shown with circuit breakers order as extra) u8-x-hsp 5 amp/position 00 amp/position MAIN BUS RATIN LINE CONNECTOR SIZE U85--HSP 00 AMP * 8"- STUD U85--HSP 00 AMP * 8"- STUD # OF POS. CATALO vertical rectangular 5 amp/position 00 amp/position MAIN BUS RATIN LINE CONNECTOR SIZE 4 U854--HSP 400 AMP * 8"- STUD 5 U855--HSP 400 AMP * 8"- STUD # OF POS. # OF POS. CATALO CATALO MAIN BUS RATIN MAIN BUS RATIN LINE CONNECTOR SIZE U8--HSP 50 AMP * 8"- STUD U8--HSP 00 AMP * 8"- STUD LINE CONNECTOR SIZE 4 U84--HSP 400 AMP * 8"- STUD 5 U85--HSP 00 AMP * 8"- STUD 5 AMP condominium metering banks 4 TERMINAL ø 0 / 40 VAC U85--HSP 400 AMP * 8"- STUD U8--HSP 00 AMP * 8"- STUD U85-U85 plug-in breaker compatibility chart U8-U8 AMPS CUTLER HAMMER SIEMENS SIEMENS/ MURRAY.E. SQUARE D AMPS CUTLER HAMMER SIEMENS SIEMENS/ MURRAY.E. SQUARE D 5 Quicklag P / BR QP MP QLine Homeline 5-00 BR, BJ QN MD QLine Quicklag P, 5 QP MP QLine Homeline BR, HQP connector kits * SIZE SUFFI KIT # COMPATIBLE ITH SINLE TIN IRE RANE -K K59 U85-5, U8- #-50 kcmil -K K540 U854-5, U84- #4-00 kcmil -K K50 U854-5, U8- #-50 kcmil -K4 K54 U84- #-00 kcmil *connectors: For line wire connector kits, order separately. Order kit per bank. fifth terminals: For field mounted fifth terminal order catalog number K8. Order one per meter position. breakers: Units have provision for one double pole main per meter position. Breakers not included. Order as extra. 4

16 5 00 amp condominium metering banks lever bypass 0 / 40 VAC 00 amp condominium metering banks lever bypass 0 / 40 VAC # OF POS. CATALO u474-xt-5t9 00 amp/position MAIN BUS RATIN LINE CONNECTOR SIZE U47-T-5T9 0 AMP 8"- STUD U47-T-5T9 480 AMP 8"- STUD 4 U474-T-5T9 40 AMP 8"- STUD 5 U475-T-5T9 40 AMP 8"- STUD U47-T-5T9 40 AMP 8"- STUD PLU-IN BREAKER COMPATIBILITY CHART AMPS CUTLER HAMMER SIEMENS SIEMENS/ MURRAY.E. SQUARE D 5-00 BR, BJ QN MD QLine Quicklag P, 5 QP MP QLine Homeline BR, HQP line side connector kits * SIZE SUFFI KIT # COMPATIBLE ITH SINLE TIN IRE RANE -K K59 U47-7 #5-50 kcmil -K K540 U474-7 #4-00 kcmil -K K50 U47-7 #-50 kcmil -K4 K54 U474-7 #-00 kcmil *connectors: For line side connector kits, order separately. breakers: Units have provision for one double pole main per meter position. Breakers not included. Order as extra. bypass: Lever supplies clamping action on meter spades and also operates bypass device. fifth terminal: Factory installed in 9 o clock position. 5

17 00 amp condominium metering banks lever bypass 0 / 40 VAC 00 amp/pos. (- position) 7 /4" 00 amp/pos.(4,5 & position) 48" or 0" 00 amp condominium metering banks lever bypass 0 / 40 VAC k.o. dimensions,, Concentric k.o., 4,, Concentric k.o. 4, Concentric k.o. 0" 48" 45"

18 7 00 / 50 / 00 amp 4 terminal 00 VAC meter main 00 / 50 / 00 amp 4 terminal 00 VAC meter main u58-xtl terminal meter main overhead/underground k aic Øw AMPS CONNECTORS # OF CATALO HUB CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS CIRCUITS LINE LOAD D'' '' H'' U58-TL-00-KK C.P. #-50 #/0-00 HORN 4 4 8, 4,, 4 Breaker* 50 8 U58-TL-50-KK C.P. #-50 #/0-00 HORN 4 4 8, 4,, 4 Breaker* 00 8 U58-TL-00-KK C.P. #-50 #/0-00 HORN 4 4 8, 4,, 4 Breaker* 50 0 U58-TL-50-KK C.P. #-50 Breaker HORN 4 4 8, 4,, U58-TL-00-KK C.P. #-50 Breaker HORN 4 4 8, 4,, 4 hub: Supplied with () closing plates packed inside. Order hubs as a separate item. See accessory page for hub options. interior: U58 units have 8 circuit interior; U58 units have 0 circuit interior. fifth terminal: Order K5T and field install for 08Y/0 network systems. Installs in the 9 o clock position only. breakers: Rated K AIC with Milbank QNR00H main installed. interlock kit: For generator auxiliary circuit breaker interlock, order K585 for large QN with small frame Q; order K580 for large frame QN with large frame QN; order K580 for small frame Q with small frame Q. *sub-feed lugs: #-50 kcmil sub-feed lugs provided on 8 circuit interior. Not available on 0 circuit interior. main circuit breaker chart Amperage 50A - K 00A - K Catalog No. qn50rh qn00rh 7

19 50 / 00 amp ringless meter mains 5 terminal k AIC / 00 amp ringless meter mains 5 terminal k AIC u58-xtl / 00 amp 5 terminal meter main k aic 0/40 volt Øw ringless / ring type overhead / underground 8 circuit interior AMP CIRCUITS CATALO HUB CONNECTORS CU/AL LINE BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' U58-TL-50-KK-5T C.P. #-50 HORN 4 4 8, U58-TL-00-KK-5T C.P. #-50 HORN 4 4 8, 4,, 4 hub: Supplied with () closing plates packed inside. Order hubs as a separate item. See accessory page for hub options. interior: U58 units have 8-circuit interior; U58 units have 0-circuit interior. fifth terminal: Order K5T and field install for 08Y/0 network systems. Installs in the 9 o clock position only. breakers: Rated K AIC with Milbank QNR00H main installed. interlock kit: For generator auxiliary circuit breaker interlock, order K585 for large QN with small frame Q; order K580 for large frame QN with large frame QN. sub-feed lugs: #-50 kcmil sub-feed lugs provided on 8 and 0 circuit interior., 4, 8

20 9 00 amp Meter socket / load center 4 terminal ringless 00 amp Meter socket / load center 4 terminal ringless U587-L-00 4 terminal ringless AMP SERVICE CATALO HUB CONNECTORS CU/AL LINE LOAD BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' OH/U U587-L-00* C.P. #-50 CB* LEVER 4 4 8, 4 4, 00 OH/U U587-L-00** C.P. #-50 CB LEVER 4 4 8, 4 4, RATIN kaic 0 MAIN SIEMENS: QNR, QNRH SIEMENS: QNRH CIRCUIT BREAKERS BRANCH SIEMENS: QP, QPH CUTLER-HAMMER: BR, BRH, HPQ, QPH, QPF, QPHF SQUARE D: HOMELINE.E.: (50 AMP MA) THQL, THHQL, THQL-F, THHQL-F SIEMENS: QP, QPH breakers: Rated K AIC with Milbank QNR00H main installed. branch breakers: () single-pole branch circuits available. fifth terminal: Order K5T and field install for 08Y/0 network systems. Installs in the 9 o clock position only. interlock kit: For generator auxiliary circuit breaker interlock, order K585 for large QN with small frame Q; order K580 for large frame QN with large frame QN. * 8 circuit load center with sub-feed lugs. ** 0 circuit load center 9

21 0 amp 4 terminal ringless meter main with side wireway 0 0 amp continuous 400 amp max u40-o-/00 0 amp 4 terminal ringless meter main with side wireway u5059--/00-kl amp meter main with breakers side wireway w ringless 0/40 vac SERVICE CATALO HUB CONNECTORS CU/AL LINE LOAD FIFTH TERM KITS BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' 4 5 OH/U U5059--/00-KL* C.P. #4-00 /0-00 K8 LEVER , OH/U U5059--KL** C.P. #4-00 K85 LEVER , U U40-O-/00* BLANK 8" x STUDS /0-00 K8 LEVER , lever bypass: Lever supplies clamping action and operates bypass device. connectors: U40 socket is supplied with /8 - hex head nuts with Belleville washers. For connector lug kits, order as extra from chart on accessory page. Lug kit required for line side only. *BREAKERs: Supplied with () bolt-in Milbank UQFBH-00 breakers. Rated at K AIC. **Requires UQFPH- breakers sold separately. 0

22 0 amp 00 vac 5,, 8,, & 5 terminal current transformer test switch provision 0 amp 00 vac 5,, 8,, & 5 terminal current transformer test switch provision uc48-xl-ts08005 (with test switch factory installed) 4 ring type with provisions for test switch euserc compliant two piece front # OF TERMS SERVICE CATALO HUB CONNECTORS 5 OH/U UC45-L C.P. #4 - # NONE OH/U UC4-L C.P. #4 - # NONE OH/U UC48-L C.P. #4 - # NONE OH/U UC4-L C.P. #4 - # NONE OH/U UC44-L C.P. #4 - # NONE RINLESS PREIRED TEST SITCH ITH COVER # OF CATALO DIMENSIONS CONCENTRIC KO'S SERVICE HUB CONNECTORS BYPASS TERMS D'' '' H'' 4 5 OH/U UC9-RL-C- H.O. #4 - # TEST SITCH OH/U UC445-RL-C- H.O. #4 - # TEST SITCH BYPASS DIMENSIONS D'' '' 4 5 H'' CONCENTRIC KO'S 4 5 *sealing rings: Ring type units are supplied with one mr-4, screw type, sealing ring. prewiring: If factory prewiring is required consult factory before ordering. Please include meter socket catalog number, test switch number, meter form number, and a copy of your wiring diagram. See page 4. Test Switch Covers: Units on this page can be used with clear lexan cover order K88 for field-installable cover. Connectors: Units are supplied with sleeve type connectors (#4-#) Hubs: For proper hub selection see the hub suffix chart in accessory section. Provided with clear lexan test switch cover and factory installed / pre-wired test switch.

23 test switches 4, 7, & 0 pole 00 vac per ansi c.9 standard p c c key Potential Switch Line side current switch with short circuit assembly load side current switch with test jack assembly catalog number ts04-00 ts / 7 /" / 9 /" 4-pole x p pn x c c x x c c x p pn x test switches 4, 7, & 0 pole 00 vac per ansi c.9 standard n Neutral bar ( no switch ) pn Neutral potential switch catalog number 7-pole x Unused position on base Insulating barrier, isolates both sides of switch ts p p pn c c c c Custom Pole Arrangements: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply. catalog number ts ts07-00 catalog number 7-pole on a 0 pole base p x p x pn x c c c c p c c p c c pn 0-pole STANDARD COVER ts0-009 p p p pn c c c c c c ts0-00 p c c p c c p c c pn ts0-0 p p p pn c c c c c c ts0-0 c c c c c c p p p pn k88 ts0-00 p p p pn c c c c c c

24 milbank test switch worksheet milbank test switch worksheet test switch base The base is molded from a high strength, fiberglass reinforced, thermoset polyester. This material is track-resistant, flame-retardant and has low water absorption qualities. Bases are available in two standard sizes following NEMA mounting classifications. customer name: Address: phone / fax: / handle color key bk Black p Purple r br Red Brown bl gr Blue rey Y O Yellow hite Orange N reen bks BK/Stripe S /Stripe pole position chart special features feature 45 angle stops ganged handles (c) bussing colored handles engineering information: key p Potential Switch Line side current switch with c short circuit assembly c load side current switch with test jack assembly n Neutral bar ( no switch ) pn x Neutral potential switch Unused position on base Insulating barrier, isolates both sides of switch Custom Pole Arrangements: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply. number of poles q q q q other test switch cover* q yes clear black q no *Test switch covers are only available for 0 pole bases. base size q 7 pole q 0 pole

25 00 amp 4 terminal Service Entrance pedestals Lever bypass ringless 0 / 40 VAC 4 CATALO U4-O AMPS STABILIZER FOOT 0" 5 /" 4 /8" " " 55" U4 & U4 plug-in breaker compatibility chart MILBANK CUTLER- HAMMER (ESTINHOUSE) SIEMENS (ITE) SIEMENS MURRAY/ CROUSEHINDS 00 amp 4 terminal ringless.e. U4-O SQUARE D 5-00 Q, QN HQP, BR, BJ QN MD QLine Quicklag P, 00 Q QP MP QLine Homeline BR, HQP METER POSITIONS BYPASS MOUNTIN TYPE TIN LINE CONNECTORS CU/AL CIRCUIT PROV. U4-O-(AMP) SINLE LEVER POST # A-50 U4-O-(AMP) DOUBLE LEVER POST # A-50 CONCENTRIC KO'S Provisions for Main with Branch or Parallel Breakers 00 amp 4 terminal Service Entrance pedestals Lever bypass ringless 0 / 40 VAC lever bypass: Lever provides clamping action on meter spades and also operates bypass device. application: The U4 & U4 pedestals are suitable for use as service equipment or mobile home service equipment. k508 / K88 for direct burial application is included with unit. K55 for pad mount application must be ordered as extra. breakers: These units are wired as parallel mains and have provisions for six circuits: six single-pole or three double-pole breakers. Quadplex style breakers may be used in accordance to the NEC. If main breaker is used, there are provisions for two -pole breakers or four -pole breakers in series. fifth terminal: For field installed fifth terminal order catalog number K85 (neutral wire not provided) or K8 (with neutral wire). Both may be installed in o clock or 9 o clock position. 4

26 5 00 AMP SERIES U570 & U570 RINLESS METERed PEDESTALS 00 AMP SERIES U570 & U570 RINLESS METERed PEDESTALS U570-O-5T9 specifications: UL Listed 00 amp maximum, 0/40 volt, single phase, three wire meter socket Ringless meter socket with lever bypass and stainless steel latch Short circuit withstand rating K AIC. Type R construction for durable outdoor use, one piece post lockable and sealable Milbank grey polyester powder coat finish ire terminations accept copper or aluminum conductors Line & Neutral: () #-50 kcmil per phase Line round: (4) #4-/0 Load Neutral: () #-50 kcmil Load round: () #4-/0, (4) #4/ Milbank plug-in main circuit breaker. Available in 00, 5, 50 & 00 amp. Type UQFp-M. Four-circuit plated copper interior accepts () -pole or (4) -pole standard plug-in type circuit breakers up to a total of 5 amps maximum. Acceptable manufacturers: Cutler-Hammer, E or Siemens Factory or field installable receptacle bridge and receptacle / circuit breaker available. See accessories. 5

27 00 amp series u5 & U57 ringless metered pedestals 00 amp series u5 & U57 ringless metered pedestals U5-O-00S with series wired main & K R kit specifications: UL Listed 00 amp maximum, 0/40 volt, single phase, three wire meter socket Ringless meter socket with horn bypass and stainless steel latch Short circuit withstand rating K AIC. Type R construction for durable outdoor use, one piece post lockable and sealable Milbank grey polyester powder coat finish ire terminations accept copper or aluminum conductors Line & Neutral: () #-50 kcmil per phase Line round: (4) #4-/0 Load (CB): /0 to 00 kcmil per pole Load Neutral: () #-50 kcmil Load round: () #4-/0, (4) #4/ Milbank plug-in main circuit breaker. Available in 00, 5, 50 & 00 amp. Type UQFph-M. Four-circuit plated copper interior accepts () -pole or (4) -pole standard plug-in type circuit breakers up to a total of 5 amps maximum. Acceptable manufacturers: Cutler-Hammer, E or Siemens Factory or field installable receptacle bridge and receptacle / circuit breaker available. See accessories. Also available in Ring Type.

28 7 00 amp series ringless metered pedestals 00 amp series ringless metered pedestals SINLE PEDESTAL (Direct Burial) CATALO MAIN BREAKER MAIN CB BRANCH EIHT (lbs) u U5-O- 00S u UQFPH -m Circuit 8 u U5-O- 00S u UQFPH -m Circuit 8 u U5-O (parallel wired) provision for UQFPH-M Series 4 Circuit 80 u U570-O-5T9 UQFP -m-(amp) 00 4 Circuit 89 SINLE PEDESTAL (Pad Mount) U58-O- 00S UQFPH -m Circuit 8 U58-O (parallel wired) provision for UQFPH-M Series 4 Circuit 80 DOUBLE PEDESTAL (Direct Burial) u U57 -o-00s () UQFPH -m Circuit 5 u U57-O- 00S () UQFPH -m Circuit 5 u U57-O (parallel wired) provision for () UQFPh-M Series 4 Circuit u U570-O-5T9 UQFP -m-(amp) 00 4 Circuit 94 RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (order separately) CATALO DESCRIPTION u K5400 -BRIDE-pos Self-grounded two position receptacle bridge with hardware u k545 Stabilizer Foot with hardware u k505 Pad Mount Kit with hardware for U54/4 pad mount pedestals required u k5t 5th Terminal for 08y / 0 volt -wire service u k59 Bus kit to convert series-wired main breaker to parallel u k594 ire kit to convert parallel-wired main breaker to series u k450 Telephone / CATV mounting bracket (mounts left or right) k509 Penta bolt utility cover u Z MO 0A duplex FI receptacle, NEMA type 50 u 7077-MO 0A receptacle, NEMA type TT0R u Z70877-MO 50A receptacle, NEMA Type 4-50R u Q0 0A P circuit breaker u Q0 0A P circuit breaker u Q50 50A P circuit breaker u K595-0R Receptacle plate; 0, 0R configurations u K595-R Receptacle plate; R, B, 55BB configurations u K595-R Receptacle plate; R, BR configurations u K595-4 Receptacle plate; 4, 4B, 4BB 55, 55B, 55BR, 55R configurations u K Receptacle plate; 54, 0 configurations u K595-/450 Receptacle plate; /450 configuration u Z8994-SC U5, U540, U570 dead front with opening for two receptacles - MH product u 480 U5, U540, U570 dead front with opening for three receptacles Up to two receptacle / circuit breaker kits can be field-installed in each powerhead. Order mounting bridge and receptacle kits separately from above. For three receptacles or factory-installed kits, contact factory. Receptacle / circuit breaker kits include receptacle, circuit breaker, connected wire, cover plate and mounting screws. Other receptacle / circuit breaker kits available. K545 Stabilizer Foot sold separately. Recommended for double pedestals. Pad mount pedestals require K505 pad mount kit. Order separately. u Stock item availability subject to prior sale. Non-stock items minimum order quantity required. 7

29 5 AMP 5 TERMINAL JA CLAMPIN LEVER-METERED POER OUTLET RINLESS 8 temporary power outlet 5 AMP 5 TERMINAL JA CLAMPIN LEVER-METERED POER OUTLET RINLESS u509-rl-7gbgr 5 amp 5 terminal power outlet ringless 0/40 vac øw TERMS SERVICE CATALO HUB CONNECTORS CU/AL LINE BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' OH U509-RL-7BR H.O. #-50 LEVER breakers: U509 is factory wired with two () 0 amp / 0V breakers and one () 50 amp / 0-40V FCI breaker. receptacles: U509 includes two () factory installed 0 amp / 0V duplex FCI receptacles and one () 50 amp / 0-40V receptacle. by-pass: Lever supplies clamping action on meter spades and also operates bypass device. fifth terminal: Includes factory installed fifth terminal at 9 o clock. 8

30 9 OVERVIE OVERVIE Commercial Pedestals Attractive Easy to install Secure Cost-effective Un-Strut Your Stuff... ilbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Strut and backboard design Commercial Pedestal UL Listed as Industrial Control Equipment (File E855) Ringless Socket Utility Lug Landing Ring-type Socket Customer Interior standard features commercial pedestals Type R rainproof, vandal-resistant cabinet of polyurethane powder-coated steel (aluminum or stainless steel also available) UL listed as enclosed industrial control equipment (UL508) Isolated, lockable & sealable utility metering & lug landing sections Lockable customer section for distribution & control equipment with internal deadfront Print pocket inside customer section door contains wiring schematics and installation instructions Most load centers are UL listed for use with various manufacturers circuit breakers All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws) Meets EUSERC 08 and other utility standards. 9

31 APPLICATIONS & ACCESSORIES 0 applications These units are ideal for controlling and metering: Traffic signals Street lighting Irrigation / sprinkler systems Cell towers / telephone vaults Pump stations Temporary power for fairgrounds, swap meets, outdoor markets, portable offices, holiday lights, etc. Outdoor lighting for athletic fields, tennis and basketball courts, parking lots, landscaping and subdivision entrances, etc. Available Factory-Installed Options Meter sockets ring type or ringless, to 400 amp (unmetered pedestals also available) Main and branch breakers or T fuses Distribution copper load centers & panel boards Clocks / timers / relays Photoelectric cells and controls Power receptacles pin & sleeve, twist lock or straight blade Contactors definite purpose, electrical or mechanically held, IEC and mercury types Surge protection & lightning arrestors Reserve inlet generator receptacle with interlocked circuit breakers Motor starters, relays Push button controls Thermostat controls, fans and heating strips Power blocks and terminal blocks Steel, aluminum and plywood back boards Transformers Interlock devices for circuit breakers Available in steel, aluminum (raw painted or anodized) or stainless steel construction with powder-coated finish available in 8 standard colors or special ordered RAL colors. Available for applications up to 400 amp, 0V, 08V, 40V, 77V, 480V Ø or Ø. accessories: k85 Fifth terminal kit for use with ringless meter sockets cp-abk5/8 Anchor bolt kit (includes four 5/8 - x 8 anchor bolts) 05J Fifth terminal kit for use with ring-type meter sockets cp-tc7d: 7-day time clock kit cp-tc4h: 4-hour time clock kit CP-TCIRE: Male four-pin connector and wiring harness for use with time clocks other than shown cp-pe-hoa-pos HOA switch for field installation cp-pdmnt-calt Pedestal mounting base for pedestal cp-4pdmnt-calt Pedestal mounting base for 4 pedestal (includes mounting hardware) APPLICATIONS & ACCESSORIES 0

32 accessories accessories single For use with /8 - stud type units only twin twin connector kits SUFFI CAT # ( per set) - ø K K59-50 kcmil K K kcmil or () /0-50 kcmil KL K540L 4-00 kcmil or () /0-50 kcmil SUFFI CAT # (4 per set) - ø K5 K08-50 kcmil K7 K kcmil or () /0-50 kcmil SUFFI CAT # ( per set) - ø K K50-50 kcmil KL K50L 4-00 kcmil Non-rotating K4 K kcmil SUFFI CAT # (4 per set) - ø K K44-50 kcmil K8 K kcmil load tap connectors ( per set) Replaces the load side slide-in nut assembly on Milbank 00 amp sockets. Allows for a 00 amp tap location in addition to the #-50 kcmil load-side connector. k50 Includes Safety Barrier Extensions for applications over 00 VAC in Heavy Duty block. k4977-int internal hex k50-int internal hex interchangeable unit hubs hub adapter plate (Converts 4" opening to ") s84 Hub Adapter plate desc. suffix CAT. # hub adapter -RRL S84 removable hub closing plate desc. suffix CAT. # SMALL -L A755 (for -RL opening) LARE - A904 (for -R opening) SMALL "rl" opening (STANDARD) suffix SIZE Milbank # L " A754 YL 4" A755 ZL " A75 DL " A757 EL " A758 large "rl" opening (heavy-duty) suffix SIZE Milbank # F " A80 " A8 H 4" A8 O RL R L RL RRL T L YL ZL DL EL F H TOP SUFFI CHART Plain Top Small Hub Opening Large Hub Opening Small Closing Plate Large Closing Plate Large hub opening adapted small closing plate Large hub opening adapted to small hub opening Twin Large hub opening with closing plates HUB SUFFI CHART " For -RL Opening 4" For -RL Opening " For -RL Opening " For -RL Opening " For -RL Opening " For -R Opening " For -R Opening 4" For -R Opening Meter closing plate (Ring type / Ringless) 00 (ray Plastic) (Clear Plastic) Metal closing plate (For Ringless sockets): CP- triplex ground (k90) (For factory installed triplex ground add suffix -T to the catalog number.) DISCONNECT SLEeve * m5-44 (*not to be used with lever bypass sockets) TOUCH-UP PAINT A-P Light ray

33 accessories FIFTH TERMINALS Consult factory for 5th terminal selection sealing rings accessories amp plug-in fifth terminal 5t8k Bypass link (K880) (Bypass links sold in pairs) snap action mr- 00 amp fifth terminal k5t (New style block with square hole) Isolated neutral kit (K047) *HEAVY DUTY FIFTH TERMINAL (K85) (K8 without neutral wire) *Both kits for units manufactured after August, 99 screw type (Stainless Steel) mr-4 Anti-inversion clip (K480) breaker compatibility chart* AMPS MILBANK CUTLER- HAMMER (ESTINHOUSE) SIEMENS (ITE) SIEMENS MURRAY/ CROUSEHINDS.E. SQUARE D 5-00 Q, QN HQP, BR, BJ Q, QN MD QLine Quicklag P, 00 Q QP MP QLine Homeline BR, HQP *Contact your local Milbank rep for breaker compatibility.

34 uqfp plug-in series circuit breakers uqfp plug-in series circuit breakers UQFP UQFPH UQFP-M UQFPH-M 00 amp frame plug-in 0,000 aic &,000 AIC two-pole common trip AMPS 0K AIC K AIC 0K AIC K AIC IRE RANE PLU-IN PLU-IN PLU-IN PLU-IN CU AL 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 #-# #-/0 5 UQFP-5 UQFPH-5 UQFP-M-5 UQFPH-M-5 #-# #-/0 50 UQFP-50 UQFPH-50 UQFP-M-50 UQFPH-M-50 /0-00 / UQFP-75 UQFPH-75 UQFP-M-75 UQFPH-M-75 /0-00 / UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 /0-00 /0-00 UL listed: For use with 0 C or 75 C wire. UQFP: For parallel main circuit breaker applications UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. Standard packaging: 5 units per lb. carton.

35 uqfb bolt-on series circuit breakers 4 UQFB- UQFB- uqfb bolt-on series circuit breakers UQFB UQFB--MOD 00 amp frame bolt-on 0k aic & k AIC two-pole common trip 0K AIC K AIC 0K AIC IRE RANE BOLT-ON BOLT-ON bolt-on CU AL 00 UQFB-00 UQFBH-00 UQFB-00- #-# #-/0 5 UQFb-5 UQFbH-5 UQFB-5- #-# #-/0 50 UQFB-50 UQFBH-50 UQFB-50- /0-00 / UQFB-75 UQFBH-75 UQFB-75- /0-00 / UQFB-00 UQFBH-00 UQFB-00- /0-00 /0-00 UL listed: For use with 0 C or 75 C wire. UQFB: () /0-00 kcmil lugs provided on load and line side (cable-in, cable-out.) UQFB: Three pole available. Consult factory. UQFB-: () /0-00 kcmil lugs provided on load side and () line bar bus connections on line side. UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. UQFB--MOD: Replacement circuit breaker with line barriers removed. Standard packaging: 5 units per lb. carton. 4

36 5 conduit, ampacity & sccr information conduit, ampacity & sccr information type rhw & rhh (without outer covering) thw tw thw fepb ( thru ), rhw and RHH (without outer covering) RH, THH maximum number of conductors in conduit* conductor size awg,mcm conduit trade sizes (inches) /0 /0 /0 4/ *This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C a /0 /0 /0 4/ *cu b al or Cu-Clad AL a /0 /0 /0 4/ c * Allowable ampacities of insulated Copper & Aluminum conductors ( in conduit) 75 C (7 F) Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk ( ) shall not exceed 5 amps for 4 A, 0 amps for A, and 0 amps for 0 A copper: or 5 amps for A and 5 amps for 0 A aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 99 N.E.C. Manual article 0- and ANSI / UL-44 (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 75 C insulated wire conductor, sized in accordance with Table 0- of the National Electric Code. gang socket overall ampacities no. of Meter Positions A / Pos. ampacity 00A 00A 00A 5A 70A 5A / Pos. ampacity 00A 5A 50A 85A 0A 50A / Pos. ampacity 00A 5A 70A 8A 9A 00A / Pos. ampacity 00A 70A 0A 450A 58A ampacity correction factors ambient temp.c A = Size: A/MCM B = Ampere Rating for Insulation Types: FEP, RH, RH, TH, THN, HH, USE,. C = Ampere Rating for Insulation Types: RH, RH, TH, THN, HH, USE (Per NEC table 0-) correction factor ambient temp.f All meter sockets are 00 volt rated unless otherwise noted. All meter socket ampacity ratings are continuous duty unless otherwise noted. 5

37 energization of electrical equipment important note In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. before energizing A. ive equipment a thorough visual examination to determine that: ) No shipping or installation damage exists. ) Proper clearances have been maintained. ) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to: ) Verify tightness of all bolted connections (see table below). ) Manually operate all circuit breakers, switches, relays, etc. ) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization. energization of electrical equipment when energizing A. Use caution and follow established safety procedures: ) ear safety apparel. ) Use safety equipment. ) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. after energizing A. Secure the installation: ) To prevent accidental contact with energized parts, cover all openings with approved filler devices. ) To prevent unauthorized access, secure all covers and/or doors with approved security devices. ) Attach/post information to advise others of potential hazards associated with the installation. recommended torque for general applications* nominal joint description head type torque size screw nut ( inch lbs. ) /4 /4 5/ brass steel steel steel steel steel steel steel Brass Nut or Extruded Hole cu or al Busbar </8 Steel Nut or eh; cu or al Busbar >/8 Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or eh; cu or al Busbar Aluminum Extruded Hole all all all all all all all hex 0-5 in. lbs. 5-0 in. lbs 0-5 in. lbs 0-5 in. lbs in. lbs in. lbs in. lbs in. lbs. 5/ steel Steel Nut or eh; cu or al Busbar hex in. lbs. /8 steel Steel Nut hex in. lbs. / steel Steel Nut hex in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. eh: Extruded Hole cu: Copper al: Aluminum

38 7 MATERIALS & FINISHES MATERIALS & FINISHES materials steel quality The meter equipment listed in this catalog is made of galvanized steel (AISI* 90) to afford the best possible weather proofing. *American Iron and Steel Institute. steel sheet gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. (AISI 90) 4 gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. aluminum extrusion ire-terminals: Alloy; 0-T, Tin-plated for Cu/Al wire. Bus Bar: Alloy; 0-o & 0-O aluminum sheet 000 series aluminum sheet, H4, or 505 series aluminum sheet, H. here applicable thicknesses range from.04.5 copper sheet & bus Electrolytic copper with tin plating in most applications. insulating materials finish In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. rating process Light gray state of the art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. metal fasteners Zinc-coated with a chromate dip. nema rating Milbank meter sockets, CT cans and meter socket / breaker units have a type R rating. 7

39 METER FORMS 8 diagram a w with P.T. & C.T. Single Stator Meter( ) - Form S 5T Socket, Test Switch #TS04-00 DIARAM A diagram b w with C.T. Single Stator Meter( ) - Form S 5T Socket, Test Switch #TS04-00 DIARAM B diagram c w with C.T. s Single Stator Meter( ) - Form 4S T Socket, Test Switch #TS DIARAM C diagram d w or Network with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIARAM D METER FORMS (ALT.LOC.) (ALT.LOC.) P PN C C P PN C C P P C C C C P P C PN C C C P.T. I LINE N (BONDED) C.T. LOAD diagram e w with P.T. s & C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS I LINE N (BONDED) C.T. LOAD diagram f w with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS LINE I N (BONDED) C.T. C.T. LOAD diagram g 4w Y with C.T. s Stator Meter - Form S T Socket, Test Switch #TS0-009 LINE I N (BONDED) C.T. C.T. LOAD diagram h 4w Y with P.T. s & C.T. s Stator Meter - Form S T Socket, Test Switch #TS0-009 DIARAM E DIARAM F DIARAM DIARAM H P P PN C C C C C C P P PN C C C C C C P P P C C C C P P P C C C C LINE PT PT C.T. C.T. LOAD diagram i 4w Y or with C.T. s Y Stator Meter - Form 9S Stator Meter - Form 8S T Socket, Test Switch #TS0-009 LINE C.T. C.T. LOAD diagram j 4w Y with P.T. s & C.T. s Stator Meter - Form 9S T Socket, Test Switch #TS0-009 LINE N (BONDED) C.T. LOAD C.T. C.T. LINE N PT PT (BONDED) C.T. LOAD C.T. C.T. DIARAM I DIARAM J P P P PN C C C C C C P P P PN C C C C C C Prewiring: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. LINE N (BONDED) C.T. LOAD C.T. C.T. PT PT PT LINE N (BONDED) C.T. C.T. LOAD C.T. 8

40 9 ATT HOUR METER FORMS STANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED ATT HOUR METER FORMS STANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED SC SC TR TR TR and -IRE FORMS S & S and -IRE FORMS S & S with BYPASS -IRE FORM S 5th Term. 9 o'clock -IRE FORM S with BYPASS -IRE FORM S 5th Term. o'clock TR SC SC SC SC -IRE FORM S with BYPASS ELEMENT -IRE NETORK FORM S 5th TERM. 9 o'clock ELEMENT -IRE NETORK FORM S with BYPASS 5th Term. 9 o'clock ELEMENT -IRE NETORK FORM S 5th TERM. o'clock ELEMENT -IRE NETORK FORM S with BYPASS 5th Term. o'clock TR TR SC SC TR -IRE FORM 4S -IRE FORM 4S ITH BYPASS or ELEMENT 4 Y or Y FORM 4S FORM 5S or ELEMENT 4 Y or FORMS 4S & 5S with BYPASS ELEMENT 4 Y or Y FORM 7S FORM 4S with BYPASS TR TR SC SC TR ELEMENT, 4, FORM 5S ELEMENT, 4, FORM 5S with BYPASS ELEMENT, 4, FORM S or ELEMENT, 4, FORM S with BYPASS or ELEMENT 4 Y or Y FORM 9S FORM 8S TR = TRANSFORMER RATED SC = SELF CONTAINED TR TR TR or ELEMENT 4 Y or FORMS 8S & 9S with BYPASS ELEMENT 4 Y FORM S ELEMENT 4 Y FORM S with BYPASS 9

41 standard nema configurations 40 Pole wire grounding receptacles volts code 5v 5 50v 77 vac 7 straight blade wiring devices 5 amps 0 amps 0 amps Pole wire special applications 50 amps twist-lock wiring devices 5 amps 0 amps 0 amps 5-5r 5-0r 5-0r 5-50r l5-5r l5-0r l5-0r -5r -0r -0r -50r l-5r l-0r l-0r 7-5r 7-0r 7-0r 7-50r l7-5r l7-0r l7-0r Y Y Y standard nema configurations straight blade wiring devices twist-lock volts code 0 amps 0 amps 50 amps 0 amps 0 amps 5v 50v 0 Y Y Y Y Y 0-0r 0-0r 0-50r l0-0r l0-0r Pole 4 wire grounding straight blade wiring devices twist-lock volts code 5 amps 0 amps 0 amps 50 amps 0 amps 0 amps 5v 50v 4 Y Y Y Y Y Y 4-5r 4-0r 4-0r 4-50r l4-0r l4-0r pole wire grounding nema trailer straight blade volts code 0 amps 5v tt tt-0r 40

42 4 UTILITY INDE UTILITY INDE cel Energy City of Colorado Springs Pacific Power SKU MPRV-00-0R-78 MPRV MPRV-00-MB-78 MPRV-5000R-78 MPRV MPRV-BLANK-78 MPRV-BLANK-78-R-5T U5--KK U5--KK-K U5--KK U5--KK-K U54--KK U54--KK-K U55--KK U55--KK-K U5--KK U5--KK-K4 U57-L U779-RRL-5T9-KL-KL U797-O-KL-Kl U594- U85--KK U85--KK U854--KK U855--KK U85--KK U8--KK U8--KK U85--KK U8--KK U000-O-5T9-KL-KL U405-O U40-O-/00 U4-O U4-O U47-T-5T9 U47-T-5T9 U474-T-5T9 U475-T-5T9 UTILITY INDE Aquila Longmont City cel Energy City of Colorado Springs Pacific Power Aquila Longmont City SKU U47-T-5T9 U448-T U455-RRL U470-RRL U480-L-5T9 U5059--/00-KL U509-RL-7BR U5-O U5-O-00S U5-O-00S U57-O U57-O-00S U57-O-00S U58-O U58-O-00S U58-TL-00-kk U58-TL-00-KK-5T U58-TL-50-kk U58-TL-50-KK-5T U58-TL-00-kk U58-TL-50-kk U58-TL-00-kk U570-O-5T9 U570-O-5T9 U587-L-00-5T9 U587-L-50-5T9 U587-L-00-5T9 U587-L-50-5T9 U587-L-00-5T9 U7487-RL-T-kk U8750-RL-KK U90-RL-T-kk U955-RRL U970-R U970-RL U980-RL UC9-RL-C- UC445-RL-C- 4

43 PRODUCT INDE PRODUCT INDE 4 4 SKU Page # SKU Page # SKU Page # SKU Page # J...0 5T8K... A A A75... A A A A80... A8... A8... A A-P... CP-PDMNT-CALT...0 CP-... CP-4PDMNT-CALT...0 CP-ABK5/8...0 CP-PE-HOA-POS...0 CP-TC4H...0 CP-TC7D...0 CP-TCIRE...0 K K90... K50...4,5, K50L... K59...4,5, K ,5, K540L... K54...4,5, K08... K08... K44... K44... K K85...0, K K4977-INT... K50-INT... K K K K K K R...7 K5400-BRIDE-POS...7 K5400-BRIDE-POS...7 K5400-TT0...7 K K5T...7, K M MCP... MR-... MR-SS... MR-4... S84... TS TS TS TS TS TS TS TS TS TS U5--K... U5--K... U54--K... U55--K4... U5--K4... U57-L...7 U779-RRL-5T9-KL-KL. U797-O-KL-KL... U U59-O...7 U U85--HSP...4 U85--HSP...4 U854--HSP...4 U855--HSP...4 U85--HSP...4 U8--HSP...4 U8--HSP...4 U84--HSP...4 U85--HSP...4 U8--HSP...4 U000-O-5T9-KL-KL... U U8-0R...5 U8...4 U U405-O...7 U40-O-/ U4-O...4 U4-O...4 U47-T-5T9...5 U47-T-5T9...5 U474-T-5T9...5 U475-T-5T9...5 U47-T-5T9...5 U455-RRL...0 U470-RRL...0 U480-L-5T9...0 U488-O-50B...5 U488-O-0B...5 U5059--/00-KL...0 U T9-KL...0 U509-RL-7BR...8 U5-O...7 U5-O-00S...7 U5-O-00S...,7 U57-O...7 U57-O-00S...7 U57-O-00S...7 U58-O...7 U58-O-00S...7 U58-TL-00-KK...7 U58-TL-50-KK...7 U58-TL-50-KK-5T...8 U58-TL-00-KK...7 U58-TL-00-KK-5T...8 U58-TL-50-KK...8 U58-TL-00-KK...7 U587-L U587-L U7487-RL-T-KK... U8750-RL-KK... U90-RL-T-KK... U955-RRL...9 U970-RL...9 U980-RL...9 U985-RRL...8 UC4-L... UC44-L... UC45-L... UC4-L... UC48-L... UC9-RL-C-... UC445-RL-C-... UQFB UQFB UQFB UQFB UQFB UQFB UQFB UQFB UQFB UQFB UQFBH UQFBH UQFBH UQFBH UQFBH UQFP UQFP-5... UQFP UQFP UQFP UQFP-M UQFP-M-5... UQFP-M UQFP-M UQFP-M UQFPH UQFPH-5... UQFPH UQFPH UQFPH UQFPH-M UQFPH-M-5... UQFPH-M UQFPH-M UQFPH-M-00...

44 4 milbank PRODUCTS milbank PRODUCTS Other Quality Products Available from In addition to your local utility s meter mounting equipment, Milbank also manufactures supporting products, such as... Contact your local distributor or go to: to find additional product literature. Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches 4

45 NOTES 44 NOTES 44

46 45 NOTES NOTES 45

47 NOTES 4 NOTES 4

48 Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches Delandsheer Sales 0. 4th Avenue Denver, CO 80 Tel: Fax: Milbank Mfg. Co. PO Box 4908 Kansas City, MO Tel: Fax: Toll Free: COLO 8/0 (K)

Meter Mounting Equipment Colorado Area

Meter Mounting Equipment Colorado Area Meter Mounting Equipment Colorado Area U80 PROFILE U8 Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements

More information

Meter Mounting Equipment DTE Energy Area

Meter Mounting Equipment DTE Energy Area Meter Mounting Equipment DTE Energy Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Meter Mounting Equipment. Northern Indiana Public Service Co.

Meter Mounting Equipment. Northern Indiana Public Service Co. Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop

More information

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

Ohio Meter Mounting Equipment

Ohio Meter Mounting Equipment Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures

More information

ComEd Service Area Meter Mounting Equipment

ComEd Service Area Meter Mounting Equipment ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

REC Municipal Meter Mounting Equipment

REC Municipal Meter Mounting Equipment REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work

More information

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long

More information

Meter Mounting Equipment. GA/AL/FL Panhandle Area

Meter Mounting Equipment. GA/AL/FL Panhandle Area Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke

More information

Louisiana/Mississippi. Area Catalog

Louisiana/Mississippi. Area Catalog Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Louisiana & Mississippi Area Catalog

Louisiana & Mississippi Area Catalog Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

Meter Mounting Equipment Florida Area Catalog

Meter Mounting Equipment Florida Area Catalog Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert

More information

Meter Mounting Equipment Commonwealth Edison

Meter Mounting Equipment Commonwealth Edison Meter Mounting Equipment Commonwealth Edison MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice

More information

Consolidated Edison Orange & Rockland Meter Mounting Equipment

Consolidated Edison Orange & Rockland Meter Mounting Equipment Consolidated Edison Orange & Rockland Meter Mounting Equipment 2 MILBANK OVERVIE Milbank Overview Energy At ork since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Upstate New York Meter Mounting Equipment

Upstate New York Meter Mounting Equipment Upstate New York Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIE Milbank Overview Energy At ork since 97 Milbank builds

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.483.534 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy

More information

Meter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market

Meter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market Meter Mounting Equipment Arkansas, W. Tennessee, N. Mississippi Market MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy

More information

Instrument Rated Metering Equipment

Instrument Rated Metering Equipment Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions

More information

Meter Mounting Equipment

Meter Mounting Equipment Meter Mounting Equipment Central Hudson Service Area New York State Electric & Gas Service Area National Grid NY Service Area Rochester Gas & Electric Service Area MILBANK OVERVIEW MILBANK OVERVIEW Charles

More information

Tennessee Area Meter Mounting Equipment

Tennessee Area Meter Mounting Equipment Tennessee Area Meter Mounting Equipment MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

PSE&G Long Island Meter Mounting Equipment

PSE&G Long Island Meter Mounting Equipment PSE&G Long Island Meter Mounting Equipment Milbank Overview Energy At Work since 927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential,

More information

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r0? 10:5 S3» ilm; , ' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *

More information

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

Commercial Pedestals Product Catalog

Commercial Pedestals Product Catalog Commercial Pedestals Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

Commercial Pedestals Product Catalog

Commercial Pedestals Product Catalog Commercial Pedestals Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank provides the tools that empower life. We enable the amazing in countless everyday ways through

More information

Commercial & Industrial Product Catalog

Commercial & Industrial Product Catalog Commercial & Industrial Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Enclosed Controls Product Catalog

Enclosed Controls Product Catalog Enclosed Controls Product Catalog Milbank Overview Energy At Work since 1927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Enclosed Controls Product Portfolio

Enclosed Controls Product Portfolio Enclosed Controls Product Portfolio Milbank is a family-owned American manufacturer headquartered in Kansas City, Mo. Since 1927, Milbank has set the standard for high quality metering equipment and enclosures.

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

Modular Metering Application Guide

Modular Metering Application Guide GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III

More information

COMMERCIAL QUICK REFERENCE

COMMERCIAL QUICK REFERENCE COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

Customer Requirements Meter Socket Configurations

Customer Requirements Meter Socket Configurations Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements

More information

Modular Metering Construction Details

Modular Metering Construction Details GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Selection and Application Guide For use in New England EQUIPMENT

Selection and Application Guide For use in New England EQUIPMENT Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Multiple Metering, Horizontal Gang - Non Lever Bypass

Multiple Metering, Horizontal Gang - Non Lever Bypass Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground

More information

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards

More information

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"

More information

General Specifications for Lighthouse Power Pedestal

General Specifications for Lighthouse Power Pedestal Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SECTION 500 METERING AND ASSOCIATED EQUIPMENT SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.

More information

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,

More information

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

6.1 Introduction Product Description... Application Description... Optional Features...

6.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................

More information

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................

More information

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module

More information

Section 6 Electric Metering: Residential

Section 6 Electric Metering: Residential Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.

More information

10. METERING General Requirements

10. METERING General Requirements 10. METERING 10.1 General Requirements A. The Company will not supply service to a Customer whose wiring is designed for resale of electricity through submetering except for recreational campgrounds, marinas,

More information

Lighthouse Power Pedestals,

Lighthouse Power Pedestals, Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized

More information

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX LAD05-9, CA 964 TITLE SHEET LAD05-9 SHEET INDEX 00 DEXTER AVE. SUITE 50 SEATTLE, WA 9809 PROJECT SUMMARY PROJECT DESCRIPTION COORDINATES LATITUDE: 33.678084 N LONGITUDE: -7.84858 W 0640 Sepulveda Blvd.

More information

Requirements for Secondary Voltage Revenue Metering (750 V and less)

Requirements for Secondary Voltage Revenue Metering (750 V and less) Requirements for Secondary Voltage Revenue Metering (750 V and less) To view the latest revision of this document go to: http://www.bchydro.com/ext/metering/ January 28, 2010 Copyright 2008 by BC Hydro.

More information

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2 Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................

More information

Volume 1 Residential and Light Commercial CA E December

Volume 1 Residential and Light Commercial CA E December Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

Power Mod. Introduction.

Power Mod. Introduction. Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information