Meter Mounting Equipment. GA/AL/FL Panhandle Area

Size: px
Start display at page:

Download "Meter Mounting Equipment. GA/AL/FL Panhandle Area"

Transcription

1 Meter Mounting Equipment GA/AL/FL Panhandle Area

2 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank Bill Martin Robert F. Waldrop, Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank Quality Metering Products for 80 Years Milbank Manufacturing Company was established in 927 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 9 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturer s representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbank s employee base of over,000 workers, along with our five manufacturing facilities comprising almost 550,000 square feet give us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 0,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Service Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs, and related accessories. If you don t find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is an important factor to remain competitive in today s electrical market. Milbank has been serving the electric utility & wholesale distribution industries for 80 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the past with dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that... FAMILY MAKES A DIFFERENCE! 2

3 TABLE OF CONTENTS LOGIC DISCONNECTS (0-200 AMP) 0 & 60 AMP FUSIBLE/NON FUSIBLE AC DISCONNECTS AC DISCONNECT WITH GFCI PROTECTION/SPA BOX SINGLE POSITION 25 AMP TERMINAL RINGLESS 600 VAC AMP TERMINAL RINGLESS 600 VAC AMP & 5 TERMINAL RINGLESS 600 VAC AMP CONTINUOUS TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC AMP 7 TERMINAL NON JAW CLAMPING RINGLESS 600 VAC AMP 7 TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC AMP 7 TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC AMP 5, 6, 8, & TERMINAL TRANSFORMER RATED RINGLESS 600 VAC AMP 6, 8 & TERMINAL TRANSFORMER RATED RINGLESS WITH TEST SWITCH PROVISION AMP CONTINUOUS / 600 AMP MAX TERMINAL RINGLESS ØW 00 VAC AMP CONTINUOUS / 600 AMP MAX & 7 TERMINAL HEAVY DUTY RINGLESS Ø & Ø 600 VAC AMP CONTINUOUS / 600 AMP MAX 7 TERMINAL RINGLESS ØW 600 VAC TABLE OF CONTENTS MULTIPLE POSITION 200 AMP TERMINAL MULTIPLE POSITION METERING HORIZONTAL GANGS RINGLESS 00 VAC CONDOMINIUM METERING BANKS CONDOMINIUM METERING BANKS DIMENSIONAL INFORMATION METER MAINS 200 AMP TERMINAL METER SOCKET/CB COMBO SERVICE EQUIPMENT RINGLESS 20/20 VAC , 50 & 200 AMP TERMINAL METER MAIN RINGLESS 20/20 VAC AMP TERMINAL METER MAINS RINGLESS 20/20 VAC AMP TERMINAL METER MAIN WITH BREAKERS SIDE WIREWAY ØW RINGLESS 20 VAC COMMERCIAL PEDESTALS COMMERCIAL METER PEDESTALS OVERVIEW APPLICATIONS & ACCESSORIES COMMERCIAL PEDESTALS WORKSHEET METERED PEDESTALS U568 & U5268 RINGLESS METERED PEDESTALS U56, U57 & U59 RINGLESS METERED PEDESTALS POWER OUTLETS U908 & U909 UNDERGROUND SERVICE POWER OUTLET RINGLESS/RING TYPE SERIES U5000 UNMETERED SURFACE MOUNT POWER OUTLET SERIES U500 METERED SURFACE MOUNT POWER OUTLET SERIES U5200 UNMETERED PEDESTAL POWER OUTLET SERIES U500 METERED PEDESTAL POWER OUTLET MISCELLANEOUS TEST SWITCHES LUG CONNECTORS UQFP PLUG-IN SERIES CIRCUIT BREAKERS UQFB BOLT-ON SERIES CIRCUIT BREAKERS ACCESSORIES CONDUIT & AMPACITY INFORMATION ENERGIZATION OF ELECTRICAL EQUIPMENT MATERIALS AND FINISHES METER FORMS WATTHOUR METER FORMS STANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED PAGE INDEX BY SKU UTILITY INDEX BY SKU ADDITIONAL MILBANK PRODUCTS

4 LOGIC LOGIC

5 0 & 60 AMP FUSIBLE / NON-FUSIBLE AIR CONDITIONER DISCONNECTS 5 U800 (No deadfront required) U80 PROFILE U860 Milbankʼs air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and, also, complies with article 0- in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish. 0 & 60 AMP FUSIBLE / NON-FUSIBLE AIR CONDITIONER DISCONNECTS TECHNICAL INFORMATION AMP TYPE MAX H.P. # 0 FUSIBLE U FUSIBLE U NONFUSIBLE U NONFUSIBLE U LINE & LOAD WIRE RANGE GROUND WIRE RANGE DIMENSIONS WIRE RATING CU AL CU/AL D" W" H" CU C AL C #-# AWG #-# AWG #- AWG 2-5/ /75 60 /75 #-# AWG #-# AWG #- AWG /75 60 /75 #-#2 AWG #2-#2 AWG #- AWG /75 60 /75 #-# AWG #-# AWG #- AWG 2-/8 5 6-/ 60 /75 60 /75 U/L listed as Enclosed Pullout Switch Type R Rainproof, 20 VAC Six one-inch concentric knockouts 5

6 6 AC DISCONNECT / SPA BOX AC DISCONNECT / SPA BOX Combination AC Disconnect / 20 Amp GFCI Receptacle Together in Box U822-20GR 60 amp, Non-Fused AC Disconnect Duplex 20 amp GFCI Receptacle Type R Enclosure with In-Use Cover Meets NEC # 20.6 Requirements * UL Listed as Power Outlet Type R Enclosure In-Use Cover** Duplex Ground Connector " Concentric Knockouts AC DISCONNECT, 20 Volt 60 amp, Non-Fused GFCI RECEPTACLE 20 amp Reset/Test Button Padlock provision * NEC #20.6 Heating, Air- Conditioning and Refrigeration Equipment Outlet....The receptacle shall be located on the same level and within 7.5 m (25 ft.) of the heating, air-conditioning and refrigeration equipment. * NEC #20.08 Ground-Fault Circuit Interruptor protection for personnel. AMP TYPE To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position. All units are designed with a padlock provision on the cover for security. **Note: U822-20GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle). *Reprinted with permission from NFPA , National Electrical Code, Copyright 200, National Fire Protection Association, Quincy, MA This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, MA. U88-O-50GB MAX H.P. WT. # 60 NONFUSIBLE U822-20GR 0 6 LINE & LOAD CONNECTOR WIRE RANGE CU AL CU/AL #-#2 AWG #2-#2 AWG 20 volt ground fault protection UL listed, Type R rainproof Milbank reliability Easy installation 2 pole, 50 or 60 amp GFCI breaker protection Compact size: 8-/2" H x 7-/2" W x -/" D or wire installation, 20 / 20 VAC Standard package of 2 2 extra one-pole breaker spaces 00 amp overall rating Sub Panel Breaker Enclosure Use as a 00 amp, circuit sub panel enclosure U88-O has provision for (2) 2-pole or () -pole small frame breakers GROUND CONNECTOR WIRE RANGE DIMENSIONS WIRE RATING #- AWG D" W" H" CU C AL C /75 60 /75 Hot Tub Disconnect or Sub Panel Breaker Enclosure Type R Spa Box with GFCI Protection AMP TYPE WT. # BREAKER PROVISION U88-O 7 BREAKER BREAKER U88-O-50GB U88-O-60GB 8 8 LINE & LOAD CONNECTOR WIRE RANGE 6 GROUND CONNECTOR WIRE RANGE CU AL CU/AL #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 DIMENSIONS D" W" H"

7 25 AMP TERMINAL RINGLESS 600 VAC 7 25 AMP TERMINAL RINGLESS 600 VAC U787-RL-TG UAP2057-RL-TG 25 AMP TERMINAL RINGLESS SERVICE HUB CONNECTORS CU/AL LINE LOAD BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS OH/UG U787-RL-TG H.O. #6-2/0 #6-2/0 NONE OH/UG UAP2057-RL-TG H.O. #6-2/0 #6-2/0 NONE HUBS: For proper hub selection see the hub suffix chart on the accessory page. FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K2. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral and triplex ground. 7

8 8 200 AMP TERMINAL RINGLESS 600 VAC 200 AMP TERMINAL RINGLESS 600 VAC U702-RL-TG U700-XL-TG 200 AMP TERMINAL RINGLESS SERVICE HUB CONNECTORS CU/AL LINE LOAD BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS OH U702-RL-TG H.O. #6-50 #6-50 NONE , 2 OH/UG U700-XL-TG C.P. #6-50 #6-50 NONE OH/UG UAP5792-XL-TG C.P. #6-50 #6-50 NONE HUBS: For proper hub selection see the hub suffix chart on the accessory page. FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T. CONNECTORS: Extruded aluminum connectors are tin plated., 2, 2 8

9 200 AMP & 5 TERMINAL RINGLESS 600 VAC AMP & 5 TERMINAL RINGLESS 600 VAC U980-O U2569-O 200 AMP TERMINAL SIDE WIREWAY RINGLESS SERVICE HUB CONNECTORS CU/AL LINE LOAD BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS UG U980-O BLANK #6-50 #6-50 NONE UG U2569-O* BLANK /8" x 6 STUDS* #6-50 NONE , 2, 2 FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K2 for round opening, K5T for square opening. CONNECTORS: Extruded aluminum connectors are tin plated. *Line side supplied with /8"-6 hex head nuts with Belleville washers. For connector kit, order as extra: K59 (50kcmil). 9

10 0 20 AMP CONTINUOUS TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC 20 AMP CONTINUOUS TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC U079-R U29-O-KL-K2L O.D I.D. / 2.9 (5) /, / U797-O-KL-K2L SERVICE HUB OH U079-R** H.O. 20 AMP TERMINAL RINGLESS W CONNECTORS CU/AL LINE /8" x 6 STUD LOAD /8" x 6 STUD 0 BY- PASS LEVER DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS () -600 () UG U29-O-KL-K2L BLANK LEVER 7 /0-250 (2) /0-250 (2) () -600 () UG U797-O-KL-K2L BLANK LEVER 7 /0-250 (2) /0-250 (2) () -600 () UG UAP797-O-KL-K2L* BLANK LEVER 7 /0-250 (2) /0-250 (2) HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The lever supplies clamping action and also operates bypass device. CONNECTORS: Extruded aluminum connectors are tin plated. *Aluminum construction: This unit is painted aluminum. **For connectors, see page accessories page, 2 sets required, for line and for load., 2, 2, 2, 2

11 20 AMP CONTINUOUS TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC AMP CONTINUOUS 00 AMP MAX. 28 U28-X 20 AMP CONTINUOUS TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC 20 AMP TERMINAL SIDE WIREWAY RINGLESS W SERVICE HUB CONNECTORS CU/AL LINE LOAD BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS OH/UG U28-X C.P. /8" x 6 STUD /8" x 6 STUD LEVER ,, HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Stud type unit supplied with /8"-6 hex head nuts with Belleville washers. For connector kits, order as extra: For single K59 (50kcmil) or K50 (600kcmil). For twin lug connectors order as extra: K50 (50kcmil). Separate kits are required for both line and load.

12 2 200 AMP 7 TERMINAL RINGLESS NON JAW CLAMPING 600 VAC 200 AMP 7 TERMINAL RINGLESS NON JAW CLAMPING 600 VAC U72-RXL 200 AMP 7 TERMINAL RINGLESS W SERVICE HUB CONNECTORS CU/AL LINE LOAD BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS OH/UG U72-RXL C.P. #6-50 #6-50 LEVER , 2 HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever operates bypass device only; does not provide clamping action on meter spades. CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex neutral. For field installed isolated neutral, order kit number K07. 2

13 200 AMP 7 TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC AMP 7 TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC U970-RRL 200 AMP 7 TERMINAL RINGLESS W SERVICE HUB CONNECTORS CU/AL LINE LOAD BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS OH/UG U970-RRL H.O. #6-50 #6-50 LEVER OH/UG UAP970-RRL H.O. #6-50 #6-50 LEVER , 2, 2 HUBS: For proper hub selection see the hub suffix chart on the accessory page. INSULATED NEUTRAL: For field installed insulated neutral for catalog numbers U970 and UAP970 order kit number K07.

14 20 AMP CONTINUOUS 7 TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC 20 AMP CONTINUOUS 7 TERMINAL JAW CLAMPING LEVER RINGLESS 600 VAC U220-X AMP CONTINUOUS 00 AMP MAX U259-X SERVICE HUB UH U220-X C.P. 20 AMP SIDE WIREWAY 7 TERMINAL RINGLESS W CONNECTORS CU/AL LINE /8" x 6 STUD LOAD /8" x 6 STUD BY- PASS LEVER DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS /8" x 6 /8" x 6 OH/UG U259-X C.P. LEVER STUD STUD 8 HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Stud type units supplied with /8"-6 hex head nuts with Belleville washers. For single lug connector kits, order as extra: K082 (50kcmil) or K (600kcmil). For twin lug connectors order as extra: K2 (50kcmil). Separate kits are required for both line and load. 2,, 2,,

15 20 AMP 5, 6, 8 & TERMINAL TRANSFORMER RATED RINGLESS 600 VAC 5 Block with detail Block Assembly for UC727-RL (Prefix UC designates sleeve connector for # wire maximum) 20 AMP 5, 6, 8 & TERMINAL TRANSFORMER RATED RINGLESS 600 VAC NO. OF TERMS METER FORM RINGLESS PLUNGER TYPE BYPASS HUB CONNECTORS CU BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS S UC290-RL H.O. # - # MAX YES S UC299-RL H.O. # - # MAX YES S UC725-RL H.O. # - # MAX YES , 8, 9 & (ALT) 0S UC727-RL H.O. # - # MAX YES HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Plunger type bypass automatically closes when meter is removed. CONNECTORS: Units are supplied with sleeve type connectors (# max.) 5

16 6 20 AMP 6, 8 & TERMINAL TRANSFORMER RATED RINGLESS WITH TEST SWITCH PROVISION 600 VAC 20 AMP 6, 8 & TERMINAL TRANSFORMER RATED RINGLESS WITH TEST SWITCH PROVISION 600 VAC UC79-XL 5 2 UC752-RL-TS0-009 (shown prewired with Milbank Test Switch) UC778-YL NO. OF TERMS METER FORM PIECE COVER RINGLESS WITH TEST SWITCH PROVISION * HUB CONNECTORS CU BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS S UC778-RL H.O. # - # MAX NONE S UC7-RL H.O. # - # MAX NONE , 8, 9 & (ALT) 0S UC75-RL H.O. # - # MAX NONE , 2, 2, 2 NO. OF TERMS 2 PIECE COVER RINGLESS WITH TEST SWITCH PROVISION * HUB CONNECTORS CU BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS UC752-RL H.O. # - # MAX NONE UC78-RL H.O. # - # MAX NONE UC79-RL H.O. # - # MAX NONE HUBS: For proper hub selection see the hub suffix chart on the accessory page. PREWIRING: If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. CONNECTORS: Units are supplied with sleeve type connectors (# max.) TEST SWITCH COVER: Units on this page are not designed for use with test switch covers. SERVICE: Units are rated for overhead or underground service., 2, 2, 2 6

17 TEST SWITCHES, 7 & 0 POLE 600 VAC PER ANSI C2.9 STANDARD 7 7 /2" & 7 Pole Base 9 /2" 7 & 0 Pole Base KEY /2" /2" TS0-00 TS0-00 -POLE X P Pn X C C X X C C X P Pn X 7-POLE TEST SWITCHES, 7 & 0 POLE 600 VAC PER ANSI C2.9 STANDARD P C Potential Switch Line side current switch with short circuit assembly TS P P Pn C C C C C Load side current switch with test jack assembly N Neutral bar ( no switch ) Pn X Neutral potential switch Unused position on base 7-POLE ON A 0 POLE BASE Insulating barrier, isolates both sides of switch TS P X P X P X C C C C CUSTOM POLE ARRANGEMENTS: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply. TS0-009 TS0-00 TS0-0 TS POLE P P P Pn C C C P C C P C C P P P P Pn C C C C C C C C C P C C C P C C C P C Pn C Pn 7

18 8 80 AMP CONTINUOUS / 600 AMP MAX TERMINAL RINGLESS W 00 VAC 80 AMP CONTINUOUS / 600 AMP MAX TERMINAL RINGLESS W 00 VAC PROVISION FOR BOLT-IN BYPASS 2 5 U66-X TERMINAL RINGLESS W OVERHEAD / UNDERGROUND SERV. HUB CONNECTOR CU/AL LINE LOAD DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS (INCHES) 2 5 OH/UG U66-X-8507 () Large C.P. (-X) /2"-20 STUD /2"-20 STUD 6 7 6, 2,, 2,, 2, 2, APPLICATION: For use with W self-contained type MS-K watthour meters. CAPACITY: 80 amperes continuous / 600 amp max. TERMINALS: /2"-20 steel studs with nuts and captive Belleville washers to accommodate various bolt-on type lugs for conductors from #6 to 800 kcmil. ENCLOSURE: Constructed of gauge galvanized steel suitable for indoor or outdoor installations. Ringless cover. METER MOUNTING: Two position stud type. One set of studs provides out-of-service storage. The inservice studs are positioned so the meter cannot be installed upside-down. Full travel meter opening slide plate eliminates the need for repositioning the slide plate for the IN or OUT OF SERVICE position. BLOCKS: Glass fiber reinforced polyester plastic. High arc withstand strength and track resistant. Provisions for lightning arresters. WEIGHT: 58 lbs. approximate. CONNECTORS: Phase and neutral connectors not included. For lug connector kit explanation see accessories page. 8

19 80 AMP CONTINUOUS 600 AMP MAX & 7 TERMINAL HEAVY DUTY RINGLESS & 600 VAC AMP MAX 80 AMP CONTINUOUS PROVISION FOR BOLT-IN BYPASS (SUPPLIED BY UTILITY) U667-X-8528 WIRE RANGE TYPE WIRE ENTRY Z7096-AC SINGLE SIDE 80 AMP CONTINUOUS 600 AMP MAX & 7 TERMINAL HEAVY DUTY RINGLESS & 600 VAC Z7092-AC SINGLE FRONT Z7098-AC #-50 TWIN FRONT Z7099-AC #6-50 TWIN SIDE Z7069-AC #2-500 TWIN SIDE Z7069-AC #-500 TWIN FRONT Z7085-AC #6-250 TRIPLE FRONT & 7 TERMINAL RINGLESS PHASE HUB CONNECTORS LINE/LOAD GROUND LUG DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS 2 5 U667-X-8528 C.P. NONE #2 / , U667-XT-9526 C.P.(2) NONE #2 / , *UA667-XT-9527 C.P.(2) NONE #2 / , *UA667-X-8062 C.P. 7099/7098 #2 / , *UA667-X-8529 C.P. NONE #2 / , U66-XT-9507 C.P. NONE #2 / , U667-X-806 C.P. 7099/7098 #2 / , HUBS: For proper hub selection, see the hub suffix chart on the accessory page. CONNECTORS: Units require a total of 8 connectors. These units are supplied with two ground lugs. Order line and load connectors as extra. See chart above for ordering information. *ALUMINUM CONSTRUCTION: This unit is constructed of aluminum. 9

20 20 80 AMP CONTINUOUS / 600 AMP MAX 7 TERMINAL RINGLESS W 600 VAC 80 AMP CONTINUOUS / 600 AMP MAX 7 TERMINAL RINGLESS W 600 VAC U667-XT-BAR-9572 (Shown without connectors) PROVISION FOR BOLT-IN BYPASS U667-XT-BAR-9572 UA667-XT TERMINAL RINGLESS W OVERHEAD / UNDERGROUND PHASE HUB CONNECTORS LINE/LOAD GROUND LUG DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS 2 5 U667-XT-BAR-9572 C.P.(2) 7069 / 7069 #2 / , UA667-XT-950 C.P.(2) /2"-20 STUD #2 / , APPLICATION: For use with self-contained Type MT-K watthour meters on W wye or -wire delta services. CAPACITY: 80 amperes continuous / 600 amperes maximum. TERMINALS: /2"-20 plated steel studs with nuts and captive Belleville washers to accommodate various bolt-on type lugs for conductors from #6 to 800 kcmil CU or AL. ENCLOSURE: Constructed of gauge galvanized steel suitable for indoor or outdoor installations. Ringless cover. UA667-XT-950 has aluminum enclosure. Consult factory. (-BAR) suffix provides Lexan barrier. METER MOUNTING: The meter is mounted on 6 studs using 5/6"-2 studs with nuts with captive Belleville washers. The upper studs are positioned so that the meter cannot be installed upside down. Use /2" insulated wrench. Another set of studs provides on site out-of-service storage. Full travel meter opening slide plate eliminates the need for re-positioning the slide plate for the IN or OUT OF SERVICE position. WEIGHT: 7 lbs. approximate. CONNECTORS: Phase and neutral connectors included on U667-XT-BAR UA667-XT-950 with /2"-20 studs require (8) connectors for line & load. For Lug connector kit explanation refer to chart on page 6. 20

21 LUG CONNECTORS 2 SCE&G APPROVED K & K7 METER SOCKET CONNECTORS (FOR USE WITH A & A SERVICE) Milbank Catalog Number U66-X amp Terminal W OH / UG K (for use on A 20 / 20V service) Lug Requirements: Option : Overhead Line Side Load Side Neutral (2) Z70555-AC Single /0-800 kcmil side entry (2) Z7082-AC Single /0-800 kcmil bottom entry (2) Z7092-AC Single /0-800 kcmil front entry Option 2: Underground Line Side (2) Z7097-AC Parallel #6-50 kcmil side entry Load Side Neutral Milbank Catalog Number (2) Z70556-AC Parallel #6-50 kcmil bottom entry () Z70520-AC Quad #6-50 kcmil front entry U667-XT amp continuous 600 amp max 7 Terminal W 600V WYE or DELTA OH / UG K7 Lug Requirements: Option : Overhead (8) Z7092-AC Single /0-800 kcmil front entry Option 2: Underground () Z7096-AC Single /0-800 kcmil side entry (5) Z7092-AC Single /0-800 kcmil front entry Option : Overhead (8) Z7098-AC Parallel #-50 kcmil front entry Option : Underground () Z7099-AC Parallel #6-50 kcmil side entry (5) Z7098-AC Parallel #-50 kcmil front entry #Z7096-AC #58852 #Z7092-AC #5676 #Z7098-AC #5672 LUG CONNECTORS CONNECTOR WIRE RANGE TYPE WIRE ENTRY Z7096-AC /0-800 kcmil SINGLE SIDE Z7092-AC /0-800 kcmil SINGLE FRONT Z7098-AC #-50 kcmil TWIN FRONT Z7099-AC #6-50 kcmil TWIN SIDE Z7069-AC #2-500 kcmil TWIN SIDE Z7069-AC Z70555-AC Z7082-AC Z7097-AC Z70556-AC Z70520-AC #-500 kcmil /0-800 kcmil /0-800 kcmil #6-50 kcmil #6-50 kcmil #6-50 kcmil TWIN SINGLE SINGLE TWIN TWIN QUAD FRONT SIDE BOTTOM SIDE BOTTOM FRONT #Z70520-AC #5626 #Z7099-AC #5885 2

22 22 50 & 200 AMP TERMINAL MULTIPLE POSITION RINGLESS W 50 & 200 AMP TERMINAL MULTIPLE POSITION RINGLESS W 252 U252-X-K Bottom 256 Bottom 50 & 200 AMP TERMINAL MULTIPLE POSITION RINGLESS W OH/UG* AMPS NO. CONNECTOR OF HUB CU/AL BY- DIMENSIONS CONCENTRIC K.O.ʼS PASS POS. LINE LOAD D" W" H" /8" x U22-X-HSP C.P. STUD #6-50 NONE /8" x 6 50 U2-X-HSP C.P. STUD #6-50 NONE ()2 2 2 /8" x 6 50 U2-X-HSP C.P. STUD #6-50 NONE ()2 2 2 /8" x U25-X-HSP C.P. STUD #6-50 NONE (5) /8" x 6 6 U26-X-HSP C.P. STUD #6-50 NONE (6) U252-X-K C.P. #2-50 #6-50 NONE U252-X-HSP C.P. #2-50 #6-50 NONE U25-X-HSP C.P. #2-50 #6-50 NONE U25-X-HSP C.P. #2-50 #6-50 NONE U255-X-HSP C.P. #2-50 #6-50 NONE U256-X-HSP C.P. #2-50 #6-50 NONE All units are configured for underground service. CONNECTORS: Extruded aluminum connectors are tin plated. BUSSING: Bussing is 5/6" x " aluminum except for the, 5 & 6 position units where /8" x " aluminum bussing is supplied. *FOR OVERHEAD SERVICE: The U25-56 units are factory assembled for underground service. If overhead service is desired, an extension kit is required. Order catalog number K92 for the U25 & U255 units, and K955 for the U256 unit. FIFTH TERMINAL: For field installed fifth terminal, order catalog number K5T. 22

23 CONDOMINIUM METERING BANK 2 CONDOMINIUM METERING BANK NO. OF POS. 2 U2852-X U285-X U2866-X 25 AMP/POSITION 200 AMP/POSITION MAIN BUS RATING 200 AMP 200 AMP LINE CONNECTOR SIZE */8"-6 STUD */8"-6 STUD VERTICAL NO. OF POS. 2 U285-X-/25 (Order circuit breakers as extra) U2862-X U286-X MAIN BUS RATING 250 AMP 00 AMP LINE CONNECTOR SIZE */8"-6 STUD */8"-6 STUD NO. OF POS. U285-X MAIN BUS RATING 00 AMP LINE CONNECTOR SIZE */8"-6 STUD RECTANGULAR 25 AMP/POSITION 200 AMP/POSITION NO. OF POS. U286-X MAIN BUS RATING 00 AMP LINE CONNECTOR SIZE */8"-6 STUD 5 U2855-X 00 AMP */8"-6 STUD 5 U2865-X 600 AMP */8"-6 STUD 6 U2856-X 00 AMP */8"-6 STUD 6 U2866-X 600 AMP */8"-6 STUD SIZE SINGLE TWIN SUFFIX -K -K -K2 -K CONNECTOR KITS * KIT K59 K50 K50 K5 COMPATIBLE WITH U U U U U U U WIRE RANGE #6-50 or 2-/0 / 250 #-600 #6-50 #2-600 *CONNECTORS: For line wire connector kits, order separately. FIFTH TERMINALS: For field mounted fifth terminal order catalog number K28. Order one per meter position (9 oʼclock position only). BREAKERS: Units have provision for one double pole main per meter position. Breakers not included. Order as extra Milbank. PLUG-IN BREAKER COMPATIBILITY CHART AMPS CUTLER-HAMMER SIEMENS SIEMENS (WESTINGHOUSE) MURRAY / G.E. SQ-D (ITE) CROUSE-HINDS HQP / BR / WBJ MD THQ 00 QP / BR / HQP QP MP THQ HOMELINE 2

24 2 CONDOMINIUM METERING BANK DIMENSIONAL INFORMATION CONDOMINIUM METERING BANK DIMENSIONAL INFORMATION U2852-X 25 &200 amp/pos. (single position) 2" D D D C B " or 8" A C A 5 /6" VERTICAL 25 amp/pos. (2- position) 5 /6" E E E C B 8" 25" or 7" 200 amp/pos. (2- position) E E E B C 29" or " 5 /6" CONDOMINIUM METERING BANKS RECTANGULAR 2" 25 amp/pos. (,5 & 6 position) D 200 amp/pos. (,5 & 6 position) D FIG. A DIMENSIONS " CONCENTRIC K.O. 7" or 25" 29" or " B, 2" CONCENTRIC K.O. C " CONCENTRIC K.O. D E " HUB OPENING 2" CONCENTRIC K.O. A C A A A A A B " 7/8" C E E E B E E E 6" 7/8" 2

25 200 AMP TERMINAL METER SOCKET / CB COMBO SERVICE EQUIPMENT RINGLESS 20/20 VAC AMP TERMINAL METER SOCKET / CB COMBO SERVICE EQUIPMENT RINGLESS 20/20 VAC UAP928-RL 2 UAP502-XL AMP TERMINAL RINGLESS METER SOCKET / CB COMBO ALUMINUM CONSTRUCTION SERVICE HUB CONNECTORS CU/AL LINE BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS OH UAP928-DL 2" #6-50 NONE , 2 OH/UG UAP502-XL* C.P. #2-50 NONE , 2, 2,, 2 HUBS: Order hub as extra. Refer to accessory page. CONNECTORS: Extruded aluminum connectors are tin plated. BUSSING: Factory bussed from load side meter to line side CB section. Load side bus bars and circuit breaker interior are made from plated copper *WIREWAY: Provided with underground pull section wireway with removable cover BREAKERS: Breaker section has provision for six double pole plug-in type circuit breakers. All circuit breakers will be parallel. 25

26 26 00, 50 & 200 AMP TERMINAL METER MAIN RINGLESS 20/20 VAC 00, 50 & 200 AMP TERMINAL METER MAIN RINGLESS 20/20 VAC U9-XL-200 UL Mounting Emboss (8) TERMINAL METER MAIN RINGLESS W AMPS SERVICE HUB CONNECTOR CU/AL LINE LOAD BY- PASS DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS OH/UG 200 OH/UG 200 OH/UG U9-XL-50 C.P. #6-50 #-00 NONE U9-XL-200 C.P. #6-50 #-00 NONE U795-XL-R-200 C.P. #6-50 #-00 NONE R, 2 HUBS: For proper hub selection refer to the hub suffix chart on the accessory page. BREAKERS: Bolt-on circuit breakers are factory installed. BREAKER CHART AMPS U9-RL U9-RL U795-XL-R-200 BREAKER UQFB-50-X UQFB-200-X UQFB-200-X 26

27 20 AMP TERMINAL METER MAINS RINGLESS 20/20 VAC AMP CONTINUOUS 00 AMP MAX M00-PAR 20 AMP TERMINAL METER MAINS RINGLESS 20/20 VAC 2 M00-PAR-UG 5 5 M00-PAR-UG M00-PAR SERV. OH UG 20 AMP TERMINAL RINGLESS 200 AMP MAIN BREAKER INSTALLED M00-PAR DESCRIPTION UQFP-200 (provision for UQFP) UQFP-200 CONNECTOR CU/AL LINE #6-50 LOAD C.B. BY- PASS LEVER DIMENSIONS D" 6 8 W" 9 2 H" 7 8 CONCENTRIC K.O.ʼS M00-PAR-UG #6-50 C.B. LEVER (provision for UQFP) 2, 2, FIG. # 2 27

28 28 20 AMP METER MAIN WITH BREAKERS SIDE WIREWAY ØW RINGLESS 20 VAC 20 AMP METER MAIN WITH BREAKERS SIDE WIREWAY ØW RINGLESS 20 VAC U0-O-2/ AMP CONTINUOUS 00 AMP MAX 5059 U5059-X-2/ SERVICE 20 AMP TERMINAL METER MAIN WITH BREAKERS RINGLESS HUB UG U0-O-2/200 BLANK CONNECTORS CU/AL LINE LOAD /8" x 6 STUD #/0-00 BY- PASS LEVER DIMENSIONS D" W" H" CONCENTRIC K.O.ʼS 2 5 OH/UG U5059-X-2/200 C.P. #-600 #/0-00 LEVER CONNECTORS: The line wire section is supplied with /8"-6 studs with hex head nuts and captive Belleville washers. For single lug connector kits, order as extra: K59 (50kcmil) or K50 (600kcmil). For twin: K50 (50 kcmil.) BYPASS: The lever supplies clamping action on the meter spades and also operates the bypass device. FIFTH TERMINAL: For field installed fifth terminal order catalog number K865., 2 28

29 OVERVIEW 29 Commercial Pedestals Attractive Easy to install Secure Cost effective OVERVIEW Un-Strut Your Stuff... ilbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and costeffective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Strut and backboard design Commercial Pedestal UL Listed as Industrial Control Equipment (File E855). STANDARD FEATURES COMMERCIAL PEDESTALS Ringless Socket Utility Lug Landing Ring-type Socket Customer Interior Type R rainproof, vandal-resistant cabinet of polyurethane powder-coated steel (aluminum or stainless steel also available) UL listed as enclosed industrial control equipment (UL508) Isolated, lockable & sealable utility metering & lug landing sections Lockable customer section for distribution & control equipment with internal deadfront Print pocket inside customer section door contains wiring schematics and installation instructions Most load centers are UL listed for use with various manufacturers circuit breakers All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws) Meets EUSERC 08 and other utility standards. 29

30 0 APPLICATIONS & ACCESSORIES APPLICATIONS & ACCESSORIES APPLICATIONS These units are ideal for controlling and metering: Traffic signals Street lighting Irrigation / sprinkler systems Cell towers / telephone vaults Pump stations Temporary power for fairgrounds, swap meets, outdoor markets, portable offices, holiday lights, etc. Outdoor lighting for athletic fields, tennis and basketball courts, parking lots, landscaping and subdivision entrances, etc. AVAILABLE FACTORY-INSTALLED OPTIONS Meter sockets ring type or ringless, to 00 amp (unmetered pedestals also available) Main and branch breakers or T fuses Distribution copper load centers & panel boards Clocks / timers / relays Photoelectric cells and controls Power receptacles pin & sleeve, twist lock or straight blade Contactors definite purpose, electrical or mechanically held, IEC and mercury types Surge protection & lightning arrestors Reserve inlet generator receptacle with interlocked circuit breakers Motor starters, relays Push button controls Thermostat controls, fans and heating strips Power blocks and terminal blocks Steel, aluminum and plywood back boards Transformers Interlock devices for circuit breakers Available in steel, aluminum (raw painted or anodized) or stainless steel construction with powder-coated finish available in 8 standard colors or special ordered RAL colors. Available for applications up to 00 amp, 20V, 208V, 20V, 277V, 80V Ø or Ø. ACCESSORIES K865 Fifth terminal kit for use with ringless meter sockets 05J Fifth terminal kit for use with ring-type meter sockets CP-TC7D 7-day time clock kit CP-TC2H 2-hour time clock kit CP-TCWIRE Male four-pin connector and wiring harness for use with time clocks other than shown CP-ABK5/8 Anchor bolt kit (includes four 5/8 - x 8" anchor bolts) CP-6PDMNT-CALT Pedestal mounting base for 6" pedestal CP-2PDMNT-CALT Pedestal mounting base for 2" pedestal (includes mounting hardware) CP-PE-HOA-POS HOA switch for field installation 0

31 COMMERCIAL PEDESTAL WORKSHEET Commercial Pedestal Worksheet Phone (86)8-5 Fax (86)8-657 Please answer all of the questions as best as you can. Additional comments as to application and future requirements will help Milbank will determine the best product for your job. Distributor: Phone: Fax: Contact Name: Application: Milbank Representative: Salesmen: Job Name & Location: Agency Specifications: (DOT-City-Other) Unit Amperage: Voltage: Phase: Wire: Meter socket (200 Amp) RING-TYPE RINGLESS Fifth Terminal? NO YES (at o clock) Meter socket (200 Amp) RING-TYPE RINGLESS Fifth Terminal? NO YES (at o clock) Main breaker requirements: Amp: Poles: KAIC: Main breaker requirements: Amp: Poles: KAIC: Interior # 0-2 circuits Load center Panel board Metered? YES NO Interior #2 0-2 circuits Load center Panel board Metered? YES NO Branch breakers: Amps: Poles: KAIC: Label & Special requirements: Qty Breakers Qty Breakers Qty Breakers Qty Breakers Qty Breakers Qty Breakers Controls: Qty Time Clock: 2 Hr 7 Day 65 Day Astro Description: Qty Photo Electric Control Receptacle Qty Test switch: 2 Pos. Pos. HOA Type Other Qty Control Transformer Voltage VA Size (required for all 277/80v) Contactors: Type: Lighting - LT / Definite Purpose - DP / Mechanical Held - MH / Mercury - MV / IEC - IC Qty Type Amps Poles Coil voltage Other Qty Type Amps Poles Coil voltage Other Qty Type Amps Poles Coil voltage Other Cabinet / Finish requirements: Alum Untreated = AO / Alum Anodized = AL / Stainless Steel = SS Aluminum Painted = A / GALVANIZED STEEL PAINTED (STANDARD) (specify paint below) MINT GREEN (STANDARD) = G / Pine Green = PG / Dark Green = DG / Black = BK / Desert Tan = DT White = W / Gray = P / Summerland Gray = SG / Other (RAL finish number) Other Requirements: Please send any drawings, plans, specifications, and load/panel board schedules with worksheet COMMERCIAL PEDESTAL WORKSHEET

32 2 U568 & U5268 RINGLESS METERED PEDESTALS U568 & U5268 RINGLESS METERED PEDESTALS U568-XTL-200 shown SPECIFICATIONS Listed under UL 67 as suitable only for use as service equipment. 200 amp continuous ringless meter socket with or without horn type bypass. Accepts ANSI type C2.0 watt-hour meters. Overall ampere rating limited to main circuit breaker rating. For use on 20/20 volt single phase applications. Short circuit withstand rating 22K AIC. See wiring diagrams on back page for series rating compatibility. Type R enclosure constructed with G90 galvanized steel or 5052 aluminum. Light gray polyester powder coat finish. Service entrance overhead or underground. OH has up to 2-/2 hub opening and UG has up to knockout Load exit overhead or underground. Wire terminations accept copper or aluminum conductors: Line & Neutral: # 6-50 kcmil Ground: #-2/0 Main circuit breaker: 00 amp type Q small frame, 50 & 200 amp type QN large frame. Branch circuit breaker ground and neutral: See wiring diagram on back page. Interior: 8 or 20 space copper buss accepts most manufacturers plug-in type circuit breakers. See wiring diagrams for acceptable manufacturers and models on back page. #6-50 kcmil sub-feed lugs provided on 8 circuit interior. Not available on 20 circuit interior. 2

33 U568 & U5268 ORDERING INFORMATION METER MAIN ALL-IN-ONE WITH 8 CIRCUIT INTERIOR Catalog Number Amp Main Term By-Pass Spaces U568-XTL-00* 00 00a 2p None 0 U568-XTL a 2p None 8 U568-XTL a 2p None 8 U568-XTL-00-KK* 00 00a 2p Horn 0 U568-XTL-50-KK 50 50a 2p Horn 8 U568-XTL-200-KK a 2p Horn 8 U568-XTL-00-KK-5T* 00 00a 2p 5 Horn 0 U568-XTL-50-KK-5T 50 50a 2p 5 Horn 8 U568-XTL-200-KK-5T a 2p 5 Horn 8 U568 & U5268 ORDERING INFORMATION METER MAIN ALL-IN-ONE WITH 20 CIRCUIT INTERIOR Catalog Number Amp Main Term By-Pass Spaces U5268-XTL a 2p None 20 U5268-XTL a 2p None 20 U5268-XTL-50-KK 50 50a 2p Horn 20 U5268-XTL-200-KK a 2p Horn 20 * Amperage rating limited to main breaker rating. Interior has 0 branch circuit breaker provisions. HUB: Supplied with two (2) closing plates packed inside. Order hubs separately from chart below. FIFTH TERMINAL: For field installed 208Y/20 network service order K5T. Installs in the 9 oʼclock position. INTERLOCK KIT: For generator auxiliary circuit breaker interlock for large frame QN with small frame Q order K585; for large frame QN with large frame QN order K5820; for small frame Q to small frame Q order K580. For painted aluminum construction, change first three catalog letters to UAP. Consult factory. HUB CHART Conduit size -/ -/2 2 2-/2 Catalog no. A75 A755 A756 A757 A758 MAIN CIRCUIT BREAKER CHART Amperage Catalog no. Q200H QN250RH QN2200RH Stock model unit weight 7 lbs. pallet quantity 2

34 U56, U57 & U59 RINGLESS METERED PEDESTALS U56, U57 & U59 RINGLESS METERED PEDESTALS SPECIFICATIONS U S with series wired main & K GR kit UL listed conforms to EUSERC drawing number amp maximum, 20/20 volt, single phase, three wire meter socket Ringless meter socket with horn bypass and stainless steel latch Short circuit withstand rating 22K AIC. Type R construction for durable outdoor use, one piece post lockable and sealable Milbank grey polyester powder coat finish Wire terminations accept copper or aluminum conductors Line & Neutral: (2) #6-50 kcmil per phase Line Ground: () #-/0 Load (CB): 2/0 to 00 kcmil per pole Load Neutral: () #6-50 kcmil Load Ground: (2) #-/0, () #/6 Milbank plug-in main circuit breaker. Available in 00, 25, 50 & 200 amp. Type UQFPH-M. Four-circuit plated copper interior accepts (2) 2-pole or () -pole standard plug-in type circuit breakers up to a total of 25 amps maximum. Acceptable manufacturers: Cutler-Hammer, GE or Siemens Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See Accessories.

35 U56, U57 & U59 RINGLESS METERED PEDESTALS 5 SINGLE PEDESTAL (Direct Burial) MAIN BREAKER MAIN CB BRANCH WEIGHT (lbs) U56-O-00S UQFPH-M Circuit 82 U56-O-200S UQFPH-M Circuit 82 U56-O (parallel wired) provision for UQFPH-M Series Circuit 80 SINGLE PEDESTAL (Pad Mount) U58-O-200S UQFPH-M Circuit 82 U58-O (parallel wired) provision for UQFPH-M Series Circuit 80 DOUBLE PEDESTAL (Direct Burial) MAIN BREAKER MAIN CB BRANCH WEIGHT (lbs) U57-O-00S (2) UQFPH-M Circuit 5 U57-O-200S (2) UQFPH-M Circuit 5 U57-O (parallel wired) provision for (2) UQFPH-M Series Circuit DOUBLE PEDESTAL (Pad Mount) U59-O (parallel wired) provision for (2) UQFPH-M Series Circuit U56, U57 & U59 RINGLESS METERED PEDESTALS RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (ORDER SEPARATELY) # RECEPTACLE CIRCUIT BREAKER CONDUCTOR CONFIGURATION K GR 5-20R Duplex GFI 20 Amp, Pole 2 Awg GFI Rec. K500-TT0 TT0R 0 Amp, Pole 0 Awg K R 50 Amp, 2 Pole 8 Awg K500-BRIDGE-POS K500-BRIDGE-2POS K55 K505 K5T K59 K59 K50 Self-grounded one position receptacle bridge with hardware Self-grounded two position receptacle bridge with hardware Stabilizer Foot with hardware Pad Mount Kit with hardware for U58/9 pad mount pedestals required 5th Terminal for 208y / 20 volt -wire service Bus kit to convert series-wired main breaker to parallel Wire kit to convert parallel-wired main breaker to series Telephone / CATV mounting bracket (mounts left or right) Up to two receptacle / circuit breaker kits can be field-installed in each powerhead. Order mounting bridge and receptacle kits separately from above. For three receptacles or factory-installed kits, contact factory. Receptacle / circuit breaker kits include receptacle, circuit breaker, connected wire, cover plate and mounting screws. Other receptacle / circuit breaker kits available. K55 Stabilizer Foot sold separately. Recommended for double pedestals. Pad mount pedestals require K505 pad mount kit. Order separately. Stock item availability subject to prior sale. Non-stock items minimum order quantity required. 5

36 6 U908/U909 UNDERGROUND SERVICE POWER OUTLET RINGLESS/RING TYPE U908/U909 UNDERGROUND SERVICE POWER OUTLET RINGLESS/RING TYPE SPECIFICATIONS U908-O-76GBGR 25 5/6 5 /8 5/8 MILBANK Available in ringless style (U908 series) or ring type (U909 series) UL Listed 00 Amp, 20/20 Volt Underground Service Power Outlet Short circuit current withstand rating 0K RMS symmetrical amperes Type R welded enclosure for durable outdoor use Enclosure constructed with galvanized 6 gauge steel ASA 6 grey polyester powder coat finish MILBANK C L 9 Convenient concentric knock-out configurations and mounting embosses Wire terminations accept copper or aluminum conductors Service Line & Neutral: () #6-2/0 Load Ground: (2) /0-# & () #6-# Load Neutral: (2) /0-# & () #6-# Service Ground: #2-#8 Six circuit plated copper interior accepts standard plug-in type circuit breakers Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates Four terminal, ringless meter socket with stainless steel locking hasp. Ring type socket has aluminum MR-2 snap action sealing ring Lockable hinge cover and deadfront are removable for installation and maintenance. Stay-open hinge cover has safety interlock on deadfront. Deadfront must be removed before hinge cover can be removed. Tamper proof fastening available 5 / 5/6 6

37 U908/U909 UNDERGROUND SERVICE POWER OUTLET RINGLESS/RING TYPE 7 U908 / U909 STANDARD CONFIGURATIONS ORDERING INFORMATION # SOCKET TYPE DESCRIPTION U908-O Ringless Order base model and up to three factory installed receptacle/breaker kit separately from list below. Other kits available. Consult factory. U908-O-GR Ringless U908-O-55GBGR Ringless U909-O Ring type Order base model and up to three factory installed receptacle/breaker kit separately from list below. Other kits available. Consult factory. U909-O-GR Ring type U909-O-55GBGR Ring type U908/U909 UNDERGROUND SERVICE POWER OUTLET RINGLESS/RING TYPE RECEPTACLE & CIRCUIT BREAKER KITS NEMA AMP BLADE VOLTAGE CONFIG. TYPE CIRCUIT BREAKER TYPE K Straight Std. Duplex 20 Amp Pole K GR 20 Straight GFI Duplex 20 Amp Pole K Straight Single 20 Amp 2 Pole K GB 20 Straight Single 20 Amp 2 Pole GFI K Straight 20/20-50 Single 0 Amp 2 Pole K500-50GB 50 Straight 20/20-50 Single 0 Amp 2 Pole GFI Flat cover may not close completely with twist locking devices in use. Order slope-front R cover # 0768 separately to use with twist lock type receptacles. Stock item availability subject to prior sale. Non-stock items minimum order quantity required 7

38 8 SERIES U5000 UNMETERED SURFACE MOUNT POWER OUTLET SERIES U5000 UNMETERED SURFACE MOUNT POWER OUTLET U5000-XL-75 SPECIFICATIONS: UL Listed 25 Amp, 20/20 Volt, Power Outlet. Short circuit current withstand rating 0K RMS symmetrical amperes. Type R welded enclosure for durable outdoor use. Enclosure constructed with galvanized 6 gauge steel. ASA 6 grey polyester powder coat finish. Convenient concentric knock-out configurations and mounting embosses. Hub opening with closure plate allows for meter retrofit. Wire terminations accept copper or aluminum conductors for loop feed wiring. Line: (2) /0-#2 Ground: (2) /0-# & () #6-# Neutral: (2) /0-# & () #6-# Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 25 amps. Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates. Components factory wired with stranded copper wire. Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has safety interlock on dead front. Dead front cover must be removed before hinge cover can be removed. Low wattage, 20 Volt fluorescent site light available. Factory or field installable. Unit weight: 2 lbs. 8

39 SERIES U5000 UNMETERED SURFACE MOUNT POWER OUTLET 9 U5000 STANDARD MODELS # RECEPTACLES CIRCUIT BREAKERS U5000-XL- () TT0R () 0A, P, 20V () 5-20R GFI () 20A, P, 20V U5000-XL-2 (2) TT0R (2) 0A, P, 20V () 5-20R GFI () 20A, P, 20V U5000-XL-55 () -50R () 50A, 2P, 20/20V () 5-20R GFI () 20A, P, 20V U5000-XL-75 () -50R () 50A, 2P, 20/20V () TT0R () 0A, P, 20V () 5-20R GFI () 20A, P, 20V U5000-XL-75GB () -50R () 50A, 2P, 20/20V () TT0R () 0A, P, 20V () 5-20R () 20A, P, 20V, GFI SERIES U5000 UNMETERED SURFACE MOUNT POWER OUTLET U5000 STANDARD BASE MODEL Order up to () receptacle / breaker kits. Sold separately for field installation. # DESCRIPTION U5000-XL Base model without receptacles or circuit breakers. RECEPTACLE & CIRCUIT BREAKER KITS # RECEPTACLES CIRCUIT BREAKERS CONDUCTORS CONFIGURATION K GR 5-20R Duplex GFI 20 Amp, Pole 2 Awg GFI Rec. K GB 5-20R Duplex 20 Amp, Pole GFI 2 Awg GFI CB K500-TT0 TT0R 0 Amp, Pole 0 Awg K500-TT0GB TT0R 0 Amp, Pole GFI 0 Awg GFI CB K R 50 Amp, 2 Pole 8 Awg Stock model. Availability subject to prior sale. Note: 20 Amp GFI required at each RV site by UL and NEC

40 0 SERIES U500 METERED SURFACE MOUNT POWER OUTLET SERIES U500 METERED SURFACE MOUNT POWER OUTLET Loop feed not available. U500-XL-75 SPECIFICATIONS UL Listed 25 Amp, 20/20 Volt Power Outlet. This is an overhead only unit. Short circuit current withstand rating 0K RMS symmetrical amperes. Type R welded enclosure for durable outdoor use. Enclosure constructed with galvanized 6 gauge steel. ASA 6 grey polyester powder coat finish. Convenient concentric knock-out configurations and mounting embosses. Hub opening with closure plate. Wire terminations accept copper or aluminum conductors. Loop feed not available. Line: () #6-250 kcmil Ground: (2) /0-# & () #6-# Neutral: (2) /0-# & () #6-# Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 25 amps. Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates. Four terminal, drawn ring type meter socket with aluminum sealing ring. Ringless meter socket available. Use U50 prefix. Components factory wired with stranded copper wire. Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has safety interlock on dead front. Dead front must be removed before hinge cover can be removed. Low wattage, 20 Volt fluorescent site light available. Factory or field installable. Unit weight: 26 lbs. 0

41 SERIES U500 METERED SURFACE MOUNT POWER OUTLET U500 STANDARD MODELS # RECEPTACLES CIRCUIT BREAKERS U500-XL- () TT0R () 0A, P, 20V () 5-20R GFI () 20A, P, 20V U500-XL-55 () -50R () 50A, 2P, 20/20V () 5-20R GFI () 20A, P, 20V U500-XL-75 () -50R () 50A, 2P, 20/20V () TT0R () 0A, P, 20V () 5-20R GFI () 20A, P, 20V U500-XL-75GB () -50R () 50A, 2P, 20/20V () TT0R () 0A, P, 20V () 5-20R () 20A, P, 20V, GFI U500-XL-552GR (2) -50R (2) 50A, 2P, 20/20V () 5-20R GFI () 20A, P, 20V, GFI SERIES U500 METERED SURFACE MOUNT POWER OUTLET U500 STANDARD BASE MODELS Order up to () receptacle / breaker kits. Sold separately for field installation. # DESCRIPTION U500-XL U50-XL Ring-type base model without receptacles or circuit breakers. Ringless-type base model without receptacles or circuit breakers. RECEPTACLE & CIRCUIT BREAKER KITS # RECEPTACLES CIRCUIT BREAKERS CONDUCTORS CONFIGURATION K GR 5-20R Duplex GFI 20 Amp, Pole 2 Awg GFI Rec. K GB 5-20R Duplex 20 Amp, Pole GFI 2 Awg GFI CB K500-TT0 TT0R 0 Amp, Pole 0 Awg K500-TT0GB TT0R 0 Amp, Pole GFI 0 Awg GFI CB K R 50 Amp, 2 Pole 8 Awg Stock model. Availability subject to prior sale. Note: 20 Amp GFI required at each RV site by UL and NEC 55-7

42

43 SERIES U5200 UNMETERED PEDESTAL POWER OUTLET U5200 STANDARD MODELS SINGLE HEAD DBL. HEAD # # RECEPTACLES CIRCUIT BREAKERS U5200-XL- U5220-XL- () TT0R () 0A, P, 20V () 5-20R GFI () 20A, P, 20V U5200-XL-GB () TT0R () 0A, P, 20V () 5-20R () 20A, P, 20V, GFI U5200-XL-2 (2) TT0R (2) 0A, P, 20V () 5-20R GFI () 20A, P, 20V U5200-XL-75 U5220-XL-75 () -50R () 50A, 2P, 20/20V () TT0R () 0A, P, 20V () 5-20R GFI () 20A, P, 20V U5200-XL-75GB () -50R () 50A, 2P, 20/20V () TT0R () 0A, P, 20V () 5-20R () 20A, P, 20V,GFI SERIES U5200 UNMETERED PEDESTAL POWER OUTLET # U5200-XL U520-XL U5220-XL U520-XL U5200 STANDARD BASE MODELS Order up to () receptacle / breaker kits. Sold separately for field installation. DESCRIPTION Single head base model on direct burial post. Single head base model on pad mount post. Order K50 pad mount base separately. Double head base model on direct burial post. Double head base model on pad mount post. Order K50 pad mount base separately. RECEPTACLE & CIRCUIT BREAKER KITS # RECEPTACLES CIRCUIT BREAKERS CONDUCTORS CONFIGURATION K GR 5-20R Duplex GFI 20 Amp, Pole 2 Awg GFI Rec. K GB 5-20R Duplex 20 Amp, Pole GFI 2 Awg GFI CB K500-TT0 TT0R 0 Amp, Pole 0 Awg K500-TT0GB TT0R 0 Amp, Pole GFI 0 Awg GFI CB K R 50 Amp, 2 Pole 8 Awg Stock model. Availability subject to prior sale. Note: 20 Amp GFI required at each RV site by UL and NEC 55-7

44

45 SERIES U500 METERED PEDESTAL POWER OUTLET 5 SINGLE HEAD DBL. HEAD U500 STANDARD MODELS # # RECEPTACLES CIRCUIT BREAKERS U500-O- () TT0R () 0A, P, 20V () 5-20R GFI () 20A, P, 20V U500-O-55 () -50R () 50A, 2P, 20/20V () 5-20R GFI () 20A, P, 20V U500-O-75 U520-O-75 () -50R () 50A, 2P, 20/20V () TT0R () 0A, P, 20V () 5-20R GFI () 20A, P, 20V U500-O-552GR (2) -50R (2) 50A, 2P, 20/20V () 5-20R GFI () 20A, P, 20V SERIES U500 METERED PEDESTAL POWER OUTLET U500 STANDARD BASE MODELS Order up to () receptacle / breaker kits. Sold separately for field installation. # U500-O U50-O U520-O U50-O DESCRIPTION Single head base model on direct burial post. Single head base model on pad mount post. Order K50 pad mount base separately. Double head base model on direct burial post. Double head base model on pad mount post. Order K50 pad mount base separately. RECEPTACLE & CIRCUIT BREAKER KITS # RECEPTACLES CIRCUIT BREAKERS CONDUCTORS CONFIGURATION K GR 5-20R Duplex GFI 20 Amp, Pole 2 Awg GFI Rec. K GB 5-20R Duplex 20 Amp, Pole GFI 2 Awg GFI CB K500-TT0 TT0R 0 Amp, Pole 0 Awg K500-TT0GB TT0R 0 Amp, Pole GFI 0 Awg GFI CB K R 50 Amp, 2 Pole 8 Awg Stock model. Availability subject to prior sale. Note: 20 Amp GFI required at each RV site by UL and NEC

46 6 UQFP PLUG-IN SERIES CIRCUIT BREAKERS UQFP PLUG-IN SERIES CIRCUIT BREAKERS UQFP UQFP-M 200 AMP FRAME PLUG-IN 0,000 AIC & 22,000 AIC TWO-POLE COMMON TRIP AMPS 0K AIC PLUG-IN 22K AIC PLUG-IN 0K AIC PLUG-IN 22K AIC PLUG-IN WIRE RANGE CU AL 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 #-# #-/0 25 UQFP-25 UQFPH-25 UQFP-M-25 UQFPH-M-25 #-# #-/0 50 UQFP-50 UQFPH-50 UQFP-M-50 UQFPH-M-50 /0-00 2/ UQFP-75 UQFPH-75 UQFP-M-75 UQFPH-M-75 /0-00 2/ UQFP-200 UQFPH-200 UQFP-M-200 UQFPH-M-200 /0-00 2/0-00 UL LISTED: For use with 60 C or 75 C wire. UQFP: For parallel main circuit breaker applications UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. STANDARD PACKAGING: 5 units per 6 lb. carton. 6

47 UQFB BOLT-ON SERIES CIRCUIT BREAKERS 7 UQFB-X UQFB-X UQFB UQFB-X-MOD UQFB BOLT-ON SERIES CIRCUIT BREAKERS 200 AMP FRAME BOLT-ON 0K AIC & 22K AIC TWO-POLE COMMON TRIP AMPS 0K AIC BOLT-ON 22K AIC BOLT-ON 0K AIC BOLT-ON WIRE RANGE CU AL 00 UQFB-00 UQFBH-00 UQFB-00-X #-# #-/0 25 UQFB-25 UQFBH-25 UQFB-25-X #-# #-/0 50 UQFB-50 UQFBH-50 UQFB-50-X /0-00 2/ UQFB-75 UQFBH-75 UQFB-75-X /0-00 2/ UQFB-200 UQFBH-200 UQFB-200-X /0-00 2/0-00 UL LISTED: For use with 60 C or 75 C wire. UQFB: (2) /0-00 kcmil lugs provided on load and line side (cable-in, cable-out.) UQFB: Three pole available. Consult factory. UQFB-X: (2) /0-00 kcmil lugs provided on load side and (2) line bar bus connections on line side. UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. UQFB-X-MOD: Replacement circuit breaker with line barriers removed. STANDARD PACKAGING: 5 units per 6 lb. carton. 7

48 8 ACCESSORIES ACCESSORIES FIFTH TERMINALS Consult factory for 5th terminal selection SEALING RINGS amp PLUG-IN FIFTH TERMINAL 5T8K2 HEAVY DUTY JAW CLAMPING K865 (K866 w/out neutral wire) SNAP ACTION MR-2 STAINLESS STEEL MR2-SS SCREW TYPE (Stainless Steel) MR- LOAD TAP CONNECTORS ( per set) 200 amp FIFTH TERMINAL K5T (New style block with square hole) Replaces the load side slide-in nut assembly on Milbank 200 amp sockets. Allows for a 00 amp tap location in addition to the #6-50 kcmil load-side connector. BYPASS LINK K5022 Includes Safety Barrier Extensions for applications over 00 VAC. K977-INT INTERNAL HEX K5022-INT INTERNAL HEX K880 (Bypass links sold in pairs) DISCONNECT SLEEVE * M5- (*NOT TO BE USED WITH LEVER BYPASS SOCKETS) 8

49 ACCESSORIES 9 INTERCHANGEABLE UNIT HUBS ACCESSORIES HUB ADAPTER PLATE (Converts opening to 2 2 ) S82 SMALL RL" OPENING (STANDARD) SUFFIX WL YL ZL DL EL SIZE MILBANK NO. A75 A755 2 A756 2 A A758 LARGE R OPENING (HEAVY DUTY) SUFFIX F G H SIZE MILBANK NO. A80 2 A8 A82 REMOVABLE HUB CLOSING PLATE DESCRIPTION SUFFIX CAT. # STANDARD (for -RL opening) LARGE (for -R opening) -XL A755 -X A906 CLOSING COVERS METER CLOSING PLATE (Ring type / Ringless) 600 (Gray Plastic) 66 (Clear Plastic) METAL CLOSING PLATE (For Ringless sockets) CP-2 (For Ring type sockets) MCP HUB SUFFIX CHART O Plain Top WL For -RL Opening RL Small Hub Opening YL For -RL Opening R Large Hub Opening ZL 2 For -RL Opening XL Small Closing Plate DL 2 For -RL Opening X Large Closing Plate EL 2 2 For -RL Opening Large Hub Opening F For -R Opening RXL adapted to small Closing Plate G 2 For -R Opening RRL Large Hub Opening adapted to small Hub Opening H For -R Opening CONNECTOR KITS For use with /8-6 stud type units only SINGLE TWIN # ( per set) K K K K or (2) /0-250 SUFFIX KL # ( per set) K5 K K7 K -600 or (2) /0-250 SUFFIX K50L -600 or (2) /0-250 Non-rotating # ( per set) K2 K K2L K50L 6-50 Non-rotating SUFFIX K K5-600 # ( per set) K6 K K8 K SUFFIX 9

50 50 CONDUIT, AMPACITY & SCCR INFORMATION CONDUIT, AMPACITY & SCCR INFORMATION TYPE RHW & RHH (without outer covering) THW TW THW FEPB (6 thru 2), RHW and RHH (without outer covering) RH, THHW MAXIMUM OF CONDUCTORS IN CONDUIT* CONDUCTOR SIZE AWG,MCM CONDUIT TRADE SIZES (INCHES) /0 2/0 /0 / *This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C A /0 2/0 /0 / *CU B AL or Cu-Clad AL A /0 2/0 /0 / C * Allowable ampacities of insulated Copper & Aluminum conductors (W in conduit) 75 C (67 F) Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk ( ) shall not exceed 5 amps for AWG, 20 amps for 2 AWG, and 0 amps for 0 AWG copper: or 5 amps for 2 AWG and 25 amps for 0 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 99 N.E.C. Manual article and ANSI / UL- (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 75 C insulated wire conductor, sized in accordance with Table 0-6 of the National Electric Code. GANG SOCKET OVERALL AMPACITIES NO. OF METER POSITIONS A / POS. AMPACITY 200A 200A 200A 225A 270A 25A / POS. AMPACITY 200A 225A 250A 285A 0A 50A / POS. AMPACITY 200A 225A 270A 8A 96A 200A / POS. AMPACITY 200A 270A 60A 50A 528A All meter sockets are 600 volt rated unless otherwise noted. All meter socket ampacity ratings are continuous duty unless otherwise noted. 50 AMPACITY CORRECTION FACTORS AMBIENT TEMP.C A = Size: AWG/MCM B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, 2W. C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE (Per NEC table 0-6) CORRECTION FACTOR AMBIENT TEMP.F

51 ENERGIZATION OF ELECTRICAL EQUIPMENT 5 IMPORTANT NOTE In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. BEFORE ENERGIZING A. Give equipment a thorough visual examination to determine that: ) No shipping or installation damage exists. 2) Proper clearances have been maintained. ) All connections have been made. ) Equipment is clean and dry. B. Make a thorough examination to: ) Verify tightness of all bolted connections (see table below). 2) Manually operate all circuit breakers, switches, relays, etc. ) Check rigidity of all mountings, bus bars and components. ) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization. ENERGIZATION OF ELECTRICAL EQUIPMENT WHEN ENERGIZING A. Use caution and follow established safety procedures: ) Wear safety apparel. 2) Use safety equipment. ) Take action to prevent injury to yourself and others in the event of failure of the installation. ) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. AFTER ENERGIZING A. Secure the installation: ) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. ) Attach/post information to advise others of potential hazards associated with the installation. RECOMMENDED TORQUE FOR GENERAL APPLICATIONS* NOMINAL JOINT DESCRIPTION HEAD TYPE TORQUE SIZE SCREW NUT ( INCH LBS. ) / / 5/6 BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL Brass Nut or Extruded Hole CU or AL Busbar </8 Steel Nut or EH; CU or AL Busbar >/8 Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole ALL ALL ALL ALL ALL ALL ALL HEX in. lbs in. lbs 0-5 in. lbs 0-5 in. lbs 0-50 in. lbs in. lbs in. lbs in. lbs. 5/6 STEEL Steel Nut or EH; CU or AL Busbar HEX in. lbs. /8 STEEL Steel Nut HEX in. lbs. /2 STEEL Steel Nut HEX in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum 5

52 52 MATERIALS AND FINISHES MATERIALS AND FINISHES MATERIALS STEEL QUALITY The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. STEEL SHEET 6 gauge, galvanized, sheet: / oz./ sq.ft. class zinc-coated. (AISI G90) gauge, galvanized, sheet: / oz./ sq.ft. class zinc-coated. ALUMINUM EXTRUSION Wire-Terminals: Alloy; 606-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 60-o & 606-O ALUMINUM SHEET 000 series aluminum sheet, H, or 5052 series aluminum sheet, H2. Where applicable thicknesses range from COPPER SHEET & BUS Electrolytic copper with tin plating in most applications. INSULATING MATERIALS FINISH In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. RATING PROCESS Light gray state of the art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. METAL FASTENERS Zinc-coated with a chromate dip. NEMA RATING Milbank meter sockets, CT cans and meter socket / breaker units have a type R rating. 52

53 METER FORMS 5 DIAGRAM A 2W with P.T. & C.T. Single Stator Meter(2W ) - Form S 5T Socket, Test Switch #TS0-00 DIAGRAM A DIAGRAM B W with C.T. Single Stator Meter(2W ) - Form S 5T Socket, Test Switch #TS0-00 DIAGRAM B DIAGRAM C W with 2 C.T.ʼs Single Stator Meter(W ) - Form S 6T Socket, Test Switch #TS DIAGRAM C DIAGRAM D W or W Network with 2 C.T.ʼs 2 Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM D METER FORMS (ALT.LOC.) (ALT.LOC.) P PN C C P PN C C P P2 C C 2 C 2 C2 P P2 C PN C C 2 C2 P.T. I LINE N (BONDED) C.T. LOAD DIAGRAM E W Δ with 2 P.T.ʼs & 2 C.T.ʼs 2 Stator Meter - Form 5S 8T Socket, Test Switch #TS I LINE 2 N (BONDED) C.T. LOAD DIAGRAM F W Δ with 2 C.T.ʼs 2 Stator Meter - Form 5S 8T Socket, Test Switch #TS I LINE 2 N (BONDED) C.T. C.T. LOAD DIAGRAM G W Y with C.T.ʼs 2 2 Stator Meter - Form 6S T Socket, Test Switch #TS0-009 I LINE 2 N (BONDED) C.T. C.T. LOAD DIAGRAM H W Y with 2 P.T.ʼs & C.T.ʼs 2 2 Stator Meter - Form 6S T Socket, Test Switch #TS0-009 DIAGRAM E DIAGRAM F DIAGRAM G DIAGRAM H P P PN C C C C C C P P PN C C C C C C P P P2 C C C C P P P2 C C C C LINE 2 PT PT C.T. C.T. LOAD DIAGRAM I W Y or Δ with C.T.ʼs Y Stator Meter - Form 9S Δ 2 Stator Meter - Form 8S T Socket, Test Switch #TS0-009 LINE 2 C.T. C.T. LOAD DIAGRAM J W Y with P.T.ʼs & C.T.ʼs Stator Meter - Form 9S T Socket, Test Switch #TS0-009 LINE 2 N (BONDED) C.T. C.T. C.T. LOAD PT PT 2 LINE N (BONDED) C.T. C.T. LOAD C.T. DIAGRAM I DIAGRAM J P P2 P PN C C C C C C P P2 P PN C C C C C C PREWIRING: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. 2 LINE N (BONDED) C.T. C.T. LOAD C.T. PT PT PT 2 LINE N (BONDED) C.T. C.T. LOAD C.T. 5

54 5 WATTHOUR METER FORMS STANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED WATTHOUR METER FORMS STANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED SC SC TR TR TR 2 and -WIRE FORMS S & 2S TR SC SC SC SC 2-WIRE FORM S with BYPASS 2 and -WIRE FORMS S & 2S with BYPASS 2 ELEMENT -WIRE NETWORK FORM 2S 5th TERM. 9 o'clock 2-WIRE FORM S 5th Term. 9 o'clock 2 ELEMENT -WIRE NETWORK FORM 2S with BYPASS 5th Term. 9 o'clock 2-WIRE FORM S with BYPASS 2 ELEMENT -WIRE NETWORK FORM 2S 5th TERM. 6 o'clock 2-WIRE FORM S 5th Term.6 o'clock 2 ELEMENT -WIRE NETWORK FORM 2S with BYPASS 5th Term. 6 o'clock TR TR SC SC TR -WIRE FORM S -WIRE FORM S WITH BYPASS 2 or ELEMENT W Y or Y FORM S FORM 5S 2 or ELEMENT W Y or FORMS S & 5S with BYPASS 2 ELEMENT W Y or Y FORM 7S FORM 2S with BYPASS TR TR SC SC TR 2 ELEMENT 2 W, 2 W, W FORM 5S 2 ELEMENT 2 W, 2 W, W FORM 5S with BYPASS 2 ELEMENT 2 W, 2 W, W FORM S 2 or ELEMENT 2 W, 2 W, W FORM S with BYPASS 2 or ELEMENT W Y or Y FORM 9S FORM 8S TR = TRANSFORMER RATED SC = SELF CONTAINED TR TR TR 2 or ELEMENT W Y or FORMS 8S & 9S with BYPASS 2 ELEMENT W Y FORM 6S 2 ELEMENT W Y FORM 6S with BYPASS 5

55 INDEX 55 GA/AL/FL PANHANDLE PAGE INDEX BY SKU SKU PAGE # SKU PAGE # SKU PAGE # SKU PAGE # INDEX J T8K A A A A A A A A A A A A A A A CP-6PDMNT-CALT CP CP-2PDMNT-CALT CP-ABK5/ CP-PE-HOS-POS CP-TC2H CP-TC7D CP-TCWIRE K K K50L K K K K K50L K K K K K K K K K K977-INT K K5022-INT K K K K K K K K K K500-50GB K K GB K GB K GB K GB K GR K GR K GR K GR K GR K GR K K GB K500-BRIDGE-POS....5 K500-BRIDGE-2POS....5 K500-TT K500-TT K500-TT K500-TT K500-TT K500-TT0GB K500-TT0GB K500-TT0GB K500-TT0GB K K5T K5T K M00-PAR M00-PAR-UG M MCP MR MR2-SS MR Q200H QN250RH QN2200RH TS TS TS TS TS TS TS TS U079-R U29-O-KL-K2L U22-X-HSP U2-X-HSP U2-X-HSP U25-X-HSP U26-X-HPS U252-X-K U252-X-HSP U25-X-HSP U25-X-HSP U255-X-HSP U256-X-HSP U797-O-KL-K2L U980-O U220-X U28-X U2569-O U259-X U2852-X U285-X U285-X U2855-X U2856-X U2862-X U286-X U286-X U2865-X U2866-X U9-XL U9-XL U795-XL-R U U822-20GR U U U0-O-2/ U66-X U667-X U667-X U667-XT U667-XT-BAR U88-O U88-O-50GB U88-O-60GB U908-O U908-O-GR U908-O-55GBGR U909-O U909-O-GR U909-O-55GBGR U5000-XL U5000-XL U5000-XL U5000-XL U5000-XL U5000-XL-75GB U5059-X-2/ U500-XL U500-XL U500-XL U500-XL-552GR U500-XL U500-XL-75GB U50-XL U56-O U56-O U56-O-00S U56-O-200S U57-O-00S U57-O-200S U58-O U58-O-200S U59-O U568-XTL U568-XTL-00-KK U568-XTL-00-KK-5T... U568-XTL U568-XTL-50-KK U568-XTL-50-KK-5T... U568-XTL U568-XTL-200-KK U568-XTL-200-KK-5T... U5200-XL U5200-XL U5200-XL U5200-XL-GB U5200-XL U5200-XL-75GB U520-XL U5220-XL U520-XL U5268-XTL U5268-XTL-50-KK U5268-XTL U5268-XTL-200-KK U500-O U500-O U500-O U500-O-552GR U500-O U50-O U520-O U50-O U702-RL-TG U700-RL-TG U72-RXL U787-RL-TG U970-RRL U9706-RRL UA66-XT UA667-X UA667-X UA667-XT UA667-XT UAP797-O-KL-K2L....0 UAP2057-RL-TG UAP502-Xl UAP5792-XL-TG UAP928-DL UAP970-RRL UC290-RL UC299-RL UC725-RL UC727-RL UC7-RL UC75-RL UC78-RL UC79-RL UC778-RL UC752-RL UQFB UQFB-00-X UQFB UQFB-25-X UQFB UQFB-50-X UQFB UQFB-75-X UQFB UQFB-200-X UQFBH UQFBH UQFBH UQFBH UQFBH UQFP UQFP UQFP UQFP UQFP UQFPH UQFPH UQFPH UQFPH UQFPH UQFPH-M UQFPH-M UQFPH-M UQFPH-M UQFPH-M UQFP-M UQFP-M UQFP-M UQFP-M UQFP-M Z7096-AC Z7097-AC Z7098-AC Z7099-AC Z7092-AC Z7092-AC Z7069-AC Z7069-AC Z70520-AC Z70556-AC Z70555-AC Z7082-AC Z7085-AC

56 UTILITY INDEX BY SKU 56 UTILITY INDEX BY SKU 56 GA/AL/FL PANHANDLE UTILITY INDEX BY SKU J 5T8K2 A75 A755 A756 A757 A758 A755 A80 A8 A82 A906 CP-6PDMNT-CALT CP-2 CP-2PDMNT-CALT CP-ABK5/8 CP-PE-HOS-POS CP-TC2H CP-TC7D CP-TCWIRE K50 K50L K59 K50 K50L K5 K082 K08 K K2 K50 K865 K977-INT K5022 K5022-INT K505 K59 K59 K K500-50GB K K GB K GR K K GB K500-BRIDGE-POS K500-BRIDGE-2POS K500-TT0 K500-TT0GB K55 K5T K5T K880 M00-PAR M00-PAR-UG M5- MCP MR-2 MR2-SS MR- Q200H QN250RH QN2200RH TS0-00 TS0-00 TS TS TS0-009 TS0-00 TS0-0 TS0-02 U079-R X U29-O-KL-K2L U22-X-HSP U2-X-HSP U2-X-HSP U25-X-HSP U26-X-HPS U252-X-K U252-X-HSP U25-X-HSP U25-X-HSP U255-X-HSP U256-X-HSP U797-O-KL-K2L X U980-O X U220-X U28-X U2569-O U259-X X U2852-X U285-X U285-X U2855-X U2856-X U2862-X U286-X U286-X U2865-X U2866-X U9-XL-50 U9-XL-200 U795-XL-R-200 X U800 U822-20GR U80 U860 U0-O-2/200 X U66-X-8507 U667-X-806 U667-X-8528 U667-XT-9526 U667-XT-BAR-9572 U88-O U88-O-50GB U88-O-60GB U908-O U908-O-GR U908-O-55GBGR U909-O U909-O-GR U909-O-55GBGR U5000-XL U5000-XL-2 Huntsville Utilities Gulf Power SKU# UTILITIES Huntsville Utilities Gulf Power SKU# UTILITIES

57 57 UTILITY INDEX BY SKU UTILITY INDEX BY SKU 57 GA/AL/FL PANHANDLE UTILITY INDEX BY SKU CONTINUED U5000-XL- U5000-XL-55 U5000-XL-75 U5000-XL-75GB U5059-X-2/200 U500-XL U500-XL- U500-XL-55 U500-XL-552GR U500-XL-75 U500-XL-75GB U50-XL U56-O U56-O U56-O-00S U56-O-200S X U57-O-00S U57-O-200S U58-O U58-O-200S U59-O U568-XTL-00 U568-XTL-00-KK U568-XTL-00-KK-5T U568-XTL-50 U568-XTL-50-KK U568-XTL-50-KK-5T U568-XTL-200 U568-XTL-200-KK U568-XTL-200-KK-5T U5200-XL U5200-XL-2 U5200-XL- U5200-XL-GB U5200-XL-75 U5200-XL-75GB U520-XL U5220-XL U520-XL U5268-XTL-50 U5268-XTL-50-KK U5268-XTL-200 U5268-XTL-200-KK U500-O U500-O- U500-O-55 U500-O-552GR U500-O-75 U50-O U520-O U50-O U702-RL-TG X U700-RL-TG U72-RXL U787-RL-TG U970-RRL U9706-RRL UA66-XT-9507 UA667-X-8062 UA667-X-8529 UA667-XT-950 UA667-XT-9527 UAP797-O-KL-K2L X UAP2057-RL-TG X UAP502-Xl X UAP5792-XL-TG X UAP928-DL X UAP970-RRL X UC290-RL UC299-RL UC725-RL UC727-RL UC7-RL UC75-RL UC78-RL UC79-RL UC778-RL UC752-RL UQFB-00 UQFB-00-X UQFB-25 UQFB-25-X UQFB-50 UQFB-50-X UQFB-75 UQFB-75-X UQFB-200 UQFB-200-X UQFBH-00 UQFBH-25 UQFBH-50 UQFBH-75 UQFBH-200 UQFP-00 UQFP-25 UQFP-50 UQFP-75 UQFP-200 UQFPH-00 UQFPH-25 UQFPH-50 UQFPH-75 UQFPH-200 UQFPH-M-00 UQFPH-M-25 UQFPH-M-50 UQFPH-M-75 UQFPH-M-200 UQFP-M-00 UQFP-M-25 UQFP-M-50 UQFP-M-75 UQFP-M-200 Z7096-AC Z7097-AC Z7098-AC Z7099-AC Z7092-AC Z7092-AC Z7069-AC Z7069-AC Z70520-AC Z70556-AC Z70555-AC Z7082-AC Z7085-AC Huntsville Utilities Gulf Power SKU# UTILITIES Huntsville Utilities Gulf Power SKU# UTILITIES

58 ADDITIONAL MILBANK PRODUCTS 58 Other quality products available from Milbank COMMERCIAL ENCLOSURES 2007 PRICE LIST Effective June 26, 2006 Supercedes and cancels all previous Milbank lists. All prices listed within are subject to change without notice. ADDITIONAL MILBANK PRODUCTS MILBANK MFG. CO. ENCLOSURE GROUP 60 South St. Louis Street Concordia, MO 6020 Tel: Fax: Toll Free: In addition to your local utility s meter mounting equipment, Milbank also manufactures supporting products, such as... Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches Contact your local distributor or go to to find additional product literature. 58

59 NOTES 59 NOTES 59

60 Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches REPRESENTATIVE DISTRIBUTOR MILBANK MFG. CO. PO Box 9028 Kansas City, MO Tel: Fax: Toll Free: GA/AL/FL /08 (2K)

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Meter Mounting Equipment DTE Energy Area

Meter Mounting Equipment DTE Energy Area Meter Mounting Equipment DTE Energy Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

Ohio Meter Mounting Equipment

Ohio Meter Mounting Equipment Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

REC Municipal Meter Mounting Equipment

REC Municipal Meter Mounting Equipment REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long

More information

Meter Mounting Equipment. Northern Indiana Public Service Co.

Meter Mounting Equipment. Northern Indiana Public Service Co. Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop

More information

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

Meter Mounting Equipment Florida Area Catalog

Meter Mounting Equipment Florida Area Catalog Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert

More information

ComEd Service Area Meter Mounting Equipment

ComEd Service Area Meter Mounting Equipment ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

Louisiana & Mississippi Area Catalog

Louisiana & Mississippi Area Catalog Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

Meter Mounting Equipment Commonwealth Edison

Meter Mounting Equipment Commonwealth Edison Meter Mounting Equipment Commonwealth Edison MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice

More information

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work

More information

Louisiana/Mississippi. Area Catalog

Louisiana/Mississippi. Area Catalog Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Meter Mounting Equipment

Meter Mounting Equipment Meter Mounting Equipment Central Hudson Service Area New York State Electric & Gas Service Area National Grid NY Service Area Rochester Gas & Electric Service Area MILBANK OVERVIEW MILBANK OVERVIEW Charles

More information

Meter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market

Meter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market Meter Mounting Equipment Arkansas, W. Tennessee, N. Mississippi Market MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman

More information

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.483.534 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy

More information

Tennessee Area Meter Mounting Equipment

Tennessee Area Meter Mounting Equipment Tennessee Area Meter Mounting Equipment MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy

More information

Meter Mounting Equipment Colorado Area

Meter Mounting Equipment Colorado Area Meter Mounting Equipment Colorado Area milbank overview milbank overview Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. aldrop, 9-00 Robert F. aldrop, II Chairman Katrina aldrop Henke Vice Chairman

More information

PSE&G Long Island Meter Mounting Equipment

PSE&G Long Island Meter Mounting Equipment PSE&G Long Island Meter Mounting Equipment Milbank Overview Energy At Work since 927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential,

More information

Commercial Pedestals Product Catalog

Commercial Pedestals Product Catalog Commercial Pedestals Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

Instrument Rated Metering Equipment

Instrument Rated Metering Equipment Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions

More information

Commercial Pedestals Product Catalog

Commercial Pedestals Product Catalog Commercial Pedestals Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank provides the tools that empower life. We enable the amazing in countless everyday ways through

More information

Meter Mounting Equipment Colorado Area

Meter Mounting Equipment Colorado Area Meter Mounting Equipment Colorado Area U80 PROFILE U8 Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements

More information

Consolidated Edison Orange & Rockland Meter Mounting Equipment

Consolidated Edison Orange & Rockland Meter Mounting Equipment Consolidated Edison Orange & Rockland Meter Mounting Equipment 2 MILBANK OVERVIE Milbank Overview Energy At ork since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Upstate New York Meter Mounting Equipment

Upstate New York Meter Mounting Equipment Upstate New York Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIE Milbank Overview Energy At ork since 97 Milbank builds

More information

Commercial & Industrial Product Catalog

Commercial & Industrial Product Catalog Commercial & Industrial Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Enclosed Controls Product Catalog

Enclosed Controls Product Catalog Enclosed Controls Product Catalog Milbank Overview Energy At Work since 1927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r0? 10:5 S3» ilm; , ' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

Multiple Metering, Horizontal Gang - Non Lever Bypass

Multiple Metering, Horizontal Gang - Non Lever Bypass Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

Enclosed Controls Product Portfolio

Enclosed Controls Product Portfolio Enclosed Controls Product Portfolio Milbank is a family-owned American manufacturer headquartered in Kansas City, Mo. Since 1927, Milbank has set the standard for high quality metering equipment and enclosures.

More information

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue

More information

6.1 Introduction Product Description... Application Description... Optional Features...

6.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................

More information

Volume 1 Residential and Light Commercial CA E December

Volume 1 Residential and Light Commercial CA E December Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application

More information

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................

More information

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2 Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Multiple Metering, Vertical Gang

Multiple Metering, Vertical Gang Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or

More information

Selection and Application Guide For use in New England EQUIPMENT

Selection and Application Guide For use in New England EQUIPMENT Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,

More information

Lighthouse Power Pedestals,

Lighthouse Power Pedestals, Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

General Specifications for Lighthouse Power Pedestal

General Specifications for Lighthouse Power Pedestal Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4

More information

(CT, NH, ME, RI, VT, MA)

(CT, NH, ME, RI, VT, MA) Selection and application guide For use in New England States (CT, NH, ME, RI, VT, MA) Meter Mounting Equipment www.talonmetering.com 1 Meter Mounting Equipment Table of Contents Service Rating Positions

More information

Section 6 Electric Metering: Residential

Section 6 Electric Metering: Residential Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"

More information

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX LAD05-9, CA 964 TITLE SHEET LAD05-9 SHEET INDEX 00 DEXTER AVE. SUITE 50 SEATTLE, WA 9809 PROJECT SUMMARY PROJECT DESCRIPTION COORDINATES LATITUDE: 33.678084 N LONGITUDE: -7.84858 W 0640 Sepulveda Blvd.

More information

10. METERING General Requirements

10. METERING General Requirements 10. METERING 10.1 General Requirements A. The Company will not supply service to a Customer whose wiring is designed for resale of electricity through submetering except for recreational campgrounds, marinas,

More information

Requirements for Secondary Voltage Revenue Metering (750 V and less)

Requirements for Secondary Voltage Revenue Metering (750 V and less) Requirements for Secondary Voltage Revenue Metering (750 V and less) To view the latest revision of this document go to: http://www.bchydro.com/ext/metering/ January 28, 2010 Copyright 2008 by BC Hydro.

More information

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SECTION 500 METERING AND ASSOCIATED EQUIPMENT SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Metering and Service Installation:

Metering and Service Installation: Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...

More information

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module

More information

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company

More information

Contents. 4 Loadcentres

Contents. 4 Loadcentres POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

Selection and application guide. For use in Texas. Meter Mounting Equipment.

Selection and application guide. For use in Texas. Meter Mounting Equipment. Selection and application guide For use in Texas Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and General

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

UNDERGROUND SERVICES - SECONDARY

UNDERGROUND SERVICES - SECONDARY UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service

More information

Customer Requirements Meter Socket Configurations

Customer Requirements Meter Socket Configurations Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements

More information

Indianapolis Power & Light Company

Indianapolis Power & Light Company Indianapolis Power & Light Company Electric Service and Meter Manual The Electric Service & Meter Manual is not copyrighted and permission is hereby given to reproduce this document. However, the Indianapolis

More information