CT Metering. CT Metering. Meter Mounting Equipment

Size: px
Start display at page:

Download "CT Metering. CT Metering. Meter Mounting Equipment"

Transcription

1 Single Meter Sockets, Without Bypass - CT Rated Single Meter Sockets, CT Rated With Test Switch Bypass Provision Meter Socket / Enclosure Combination Cabinets - CT Rated CT Enclosures With Lift Off Covers CT Enclosures With Hinged, Lift Off Doors CT Mounting Bases CT Mounting Bases - Test Configuration Sheet CT Utility Enclosures

2 Single Meter Sockets - Without Bypass CT Rated Receive ANSI C12.10 watthour meters Overhead and underground feed (see chart) Surface mount Ring type NEMA Type 3R ANSI 61 gray E-coat finish Aluminum snap ring included UL 414 Listed ANSI C HS-13 (closed) 051HS-13 (open) Accessories AW Hub Screw Type Ring D Part/UPC Catalog Amp Service Connections Number Number Rating Jaws Type Access Line Load Neutral Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø or 3Ø OH/UG #14 - #10 #14 - #10 #14 - # HS Ø OH/UG #14 - #10 #14 - #10 #14 - # HS Ø OH/UG #14 - #10 #14 - #10 #14 - # MS Ø OH/UG #14 - #10 #14 - #10 #14 - #10 Part/UPC Catalog Overall Dimensions Top Knockout Number Number Height Width Depth Provision Layout /8 AW Hub Fig /8 AW Hub Fig /8 AW Hub Fig /8 AW Hub Fig HS /8 AW Hub Fig HS /8 AW Hub Fig MS /8 AW Hub Fig. 1 67

3 Single Meter Sockets - Without Bypass CT Rated Style # Suffixes 924 MS77-1 Conduit Hub 925 SS - Stainless Steel * HS Knockouts - Conduit Sizes 1A = 1 2" 4F = " " - 1" Top Provision See Chart * Knockouts and top provisions are not available in Stainless Steel (SS) finish Knockout Layouts Fig. 1 Top Provision 4F 4F 4F both sides 1A 68

4 Single Meter Sockets CT Rated With Test Switch Bypass Provision Test switch section under separate cover Test switch perch included Receive ANSI C12.10 watthour meters Overhead and underground feed (see chart) Surface mount Ring type NEMA Type 3R ANSI 61 gray E-coat finish Aluminum snap ring included (closed) (open) UL 414 Listed ANSI C12.7 EUSERC 339 Accessories AW Hub Screw Type Ring D Part/UPC Catalog Amp Service Connections Number Number Rating Jaws Type Access Line Load Neutral Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø or 3Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # * Ø or 3Ø OH/UG #14 - #10 #14 - #10 #14 - # * Ø OH/UG #14 - #10 #14 - #10 #14 - # * Ø OH/UG #14 - #10 #14 - #10 #14 - #10 Part/UPC Catalog Overall Dimensions Top Knockout Number Number Height Width Depth Provision Layout /8 AW Hub Fig /8 AW Hub Fig /8 AW Hub Fig /8 AW Hub Fig /8 AW Hub Fig /8 AW Hub Fig * /8 4 5 /8 AW Hub Fig * /8 4 5 /8 AW Hub Fig * /8 4 5 /8 AW Hub Fig. 2 * Not EUSERC 339 compliant. 69

5 Single Meter Sockets CT Rated With Test Switch Bypass Provision Style # Suffixes Knockouts - Conduit Sizes F - Flush Mount MS20 - Ring Protector SS - Stainless Steel * = 1 1 4" " - 1 2" Top Provision = See Chart * Knockouts and top provisions are not available in Stainless Steel (SS) finish Knockout Layouts Top Provision Fig. 1 Fig. 2 Top Provision both sides both sides Test Switch Perch Instructions Screw Perch Enclosure To offset test switch perch so that additional space is available for the use of a test switch cover, see instructions below. Drawing 1 Drawing 1 Perch 1. Remove (4) screws that hold the perch to the enclosure (see Drawing 1) 2. Flip perch over as shown (see Drawing 2) 3. Now use the screws you removed in step one and screw the perch to the enclosure, torque screws to 35 in/lbs. (see Drawing 3) Screw Perch Enclosure Drawing 1 70

6 Meter Socket / Enclosure Combination Cabinets CT Rated Removable test switch perch included Includes provisions to install model 6019/6067 CT mounts Receive ANSI C12.10 watthour meters Overhead and/or underground feed (see chart) Surface mount Ring type NEMA Type 3R ANSI 61 gray E-coat finish Aluminum snap ring included U (closed) U (open) UL 414 Listed ANSI C12.7 EUSERC 313 EUSERC 314 Part/UPC Catalog Amp Service Connections Number Number Rating Jaws Type Access Line Load Neutral Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø OH/UG #14 - #10 #14 - #10 #14 - # Ø or 3Ø OH/UG #14 - #10 #14 - #10 #14 - # U * Ø UG #14 - #10 #14 - #10 #14 - # U * Ø UG #14 - #10 #14 - #10 #14 - # U * Ø UG #14 - #10 #14 - #10 #14 - # U * Ø or 3Ø UG #14 - #10 #14 - #10 #14 - # U * Ø UG #14 - #10 #14 - #10 #14 - # U * Ø UG #14 - #10 #14 - #10 #14 - # U * Ø or 3Ø UG #14 - #10 #14 - #10 #14 - #10 Part/UPC Catalog Overall Dimensions L Top Knockout Number Number Height Width Depth Dimension Provision Layout /16 H Hub Fig /16 H Hub Fig /16 H Hub Fig /16 H Hub Fig /16 H Hub Fig /16 H Hub Fig /16 H Hub Fig U * /16 None Fig U * /16 None Fig U * /16 None Fig U * /16 None Fig U * /16 None Fig U * /16 None Fig U * /16 None Fig. 2 * Items beginning with U comply with EUSERC 314, all other items comply with EUSERC

7 Meter Socket / Enclosure Combination Cabinets Style # (U) (U) (U) (U) (U) (U) (U) Suffixes SS - Stainless Steel CT Rated Fig. 1 H-BASE Hub Fig. 2 C.T. Mounting Base Stud Locations C.T. Mounting Base Stud Locations 6 6 Alternate Locations Of Test Switch Perch Alternate Locations Of Test Switch Perch L L 8 8 Accepts 6019xx Series C.T. Mounting Bases see page Accepts 6019xx Series and 6067xx Series C.T. Mounting Bases see page 77 Test Switch Perch Body Bracket 1 /4-20 Nut (4) - Torque 45 in/lbs Perch #10-32 Tapped Holes (4 places) Test Switch Perch Instructions 1 /4-20 Nut (4) - Torque 45 in/lbs Perch Body Bracket 1 /4-20 Nut (4) - Torque 45 in/lbs Perch This enclosure is assembled with the test switch installed at a factory offset distance from the cover (see Figure 1). If a greater offset is desired, follow these instructions: 1. Loosen and remove the screws holding the perch to the bracket, remove the perch. Loosen and remove the nuts on the bracket studs. (See Figure X) Figure X Figure Y Figure Z 2. Remove and rotate the brackets 180 degrees and relocate back onto bracket studs. (See Figure Y) Then fasten the nuts back on the bracket studs and torque them to 45 in/lbs. #10-32 Screws (4) Torque 35 in/lbs Body #10-32 Screws (4) Torque 35 in/lbs 3. Place the perch on the brackets and fasten with the screws, and torque screws to 35 in/lbs. (See Figure Z) 72

8 CT Enclosures With Lift Off Covers Designed to house ANSI C12.11 current transformers Includes provision to install model 6019/6067 CT mounts Surface mount RTCT (closed) RTCT (open) Enclosure has mounting holes on back of body Covers include padlock provision, utility sealing provisions, wing nuts, and lifting handles Enclosures over 36 wide and 42 tall have two overlapping covers NEMA Type 3R ANSI 61 gray E-coat finish UL 414 Listed EUSERC 316 Part/UPC Catalog Service Use With Overall Dimensions Knockout Number Number Type Mounting Base Height Width Depth Layout RTCT 1Ø Fig RTCT 1Ø Fig RTCT 1Ø Fig RTCT 1Ø Fig RTCT 1Ø Fig RTCT 1Ø Fig RTCT 1Ø or 3Ø 6019 or Fig RTCT 1Ø or 3Ø 6019 or Fig RTCT 1Ø or 3Ø 6019 or Fig RTCT 1Ø or 3Ø 6019 or Fig RTCT 1Ø or 3Ø 6019 or Fig RTCT 1Ø or 3Ø 6019 or Fig RTCT 1Ø or 3Ø 6019 or Fig RTCT 1Ø or 3Ø 6019 or Fig RTCT 1Ø or 3Ø 6019 or Fig. 1 Part/UPC Catalog Number Number A B C E RTCT RTCT RTCT RTCT RTCT RTCT RTCT RTCT RTCT RTCT RTCT RTCT RTCT RTCT RTCT

9 CT Enclosures With Lift Off Covers Style # xxxxxx RTCT Suffixes MS40 - Mounting studs for 415 H - Universal CT Rack SS - Stainless Steel Fig. 1 Width B C E Depth Height 6 Cover Mounting Hole Device Mounting Stud A Mounting Hole Ground Lug Padlock Hasp Cover Mounting Stud With Utility Sealing Hole Provision 415 H Universal CT Rack 74

10 CT Enclosures With Hinged, Lift Off Doors Designed to house ANSI C12.11 current transformers Includes provision to install model 6019/6067 CT mounts Surface mount HRTCT (closed) HRTCT (open) Enclosure has mounting holes on back of body Covers include utility sealing provisions, wing nuts, and lifting handles DD parts include master/slave style overlapping doors NEMA Type 3R Wash and phosphate undercoat ANSI 61 gray E-coat finish UL 414 Listed EUSERC 316 Part/UPC Catalog Service Use With Overall Dimensions Knockout Number Number Type Mounting Base Height Width Depth Layout HRTCT 1Ø Fig HRTCT 1Ø Fig HRTCT 1Ø or 3Ø 6019 or Fig HRTCT 1Ø or 3Ø 6019 or Fig HRTCT 1Ø or 3Ø 6019 or Fig HRTCT 1Ø or 3Ø 6019 or Fig HRTCT 1Ø or 3Ø 6019 or Fig DDHRTCT 1Ø or 3Ø 6019 or Fig. 2 Part/UPC Catalog Number Number A B C E HRTCT HRTCT HRTCT HRTCT HRTCT HRTCT HRTCT DDHRTCT

11 CT Enclosures With Hinged, Lift Off Doors Style # xxxxxx HRTCT xxxxxx DDHRTCT Suffixes MS40 - Mounting studs for 415 H - Universal CT Rack SS - Stainless Steel Fig. 1 Slip Hinge Cover Mounting Stud With Utility Sealing Hole Provision B C E Slip Hinge (omit where H is less than 48) Padlock Hasp 6 Height Device Mounting Stud A Mounting Hole Ground Lug Width Depth Side View (cover removed) Front View (cover removed) Fig. 2 Slip Hinge B 6 E 415 H Universal CT Rack Height C Padlock Handle Ground Lug Device Mounting Stud Mounting Hole A Depth Width 76

12 CT Mounting Bases For use with CT rated enclosures For use with ANSI C12.11 bar type current transformers Bar mounts are 1 /2 studs on 1 3 /4 centers (line & load) 6019 HE 6019HELS 6019HEL UL 414 Listed ANSI C12.7 EUSERC 328A (6019 stud/stud) EUSERC 328B (6019 lug/lug) EUSERC 329A (6067 stud/stud) EUSERC 329B (6067 lug/lug) Part/UPC Catalog Amp # of C.T. Service Phase / Neutral Conductors Number Number Rating Provisions Type Access AIC Line Load A Ø or 3Ø/3W OH/UG 10K Studs Studs E Ø or 3Ø/3W OH/UG 10K Studs Studs HA Ø or 3Ø/3W OH/UG 50K Studs Studs HAL Ø or 3Ø/3W OH/UG 50K (3) #4-600 MCM* (3) #4-600 MCM* HALS Ø or 3Ø/3W OH/UG 50K Studs (3) #4-600 MCM* HE Ø or 3Ø/3W OH/UG 50K Studs Studs HEL Ø or 3Ø/3W OH/UG 50K (3) #4-600 MCM (3) #4-600 MCM HELS Ø or 3Ø/3W OH/UG 50K Studs (3) #4-600 MCM A Ø/4W OH/UG 10K Studs Studs EE Ø/4W OH/UG 10K Studs Studs HA Ø/4W OH/UG 50K Studs Studs HAL Ø/4W OH/UG 50K (3) #4-600 MCM* (3) #4-600 MCM* HALS Ø/4W OH/UG 50K Studs (3) #4-600 MCM* HEE Ø/4W OH/UG 50K Studs Studs HEEL Ø/4W OH/UG 50K (3) #4-600 MCM (3) #4-600 MCM HEELS Ø/4W OH/UG 50K Studs (3) #4-600 MCM Note: * Neutral Lug is one barrel only Note: Every 600 MCM lug barrel will accept (2) 1/0-250 MCM cables 77

13 CT Mounting Bases Current transformer metering Customizable configurations BMC mounting base Tin and nickel plating Color coded handles UL Recognized component ANSI C12.9 Name Company Name Address Phone Test Switch Configuration Sheet Configuration Switch (KS, SH, CN, TB, X) Bussing (B, S) Poles Ganged Handles (Y, N) Barrier (Y, N) Handle Color (R, B) 45 Stops (Y, N) Special Features Cover Yes No Base Size 7 Pole 10 Pole No. of Poles Other Plating None Tin Nickel Keys Switches KS SH CN TB X Knife Switch Knife Switch Current Switch Thru Bar Unused Space Bussing with shunt with Test Jack B Bypass S Short Handle Color Other options and arrangements are available. Please contact the factory for a full product line. Test Switched are available mounted and wired. Contact factory for details. R B Red Black For online form, see Send completed form to customer service at Eaton s B-Line Business. See address information on back cover. 78

14 CT Utility Enclosures Used for split core CT applications NEMA Type 3R ANSI 61 gray E-coat finish 3 /4 wood back panel installed Not UL Listed Utility Enclosures Part/UPC Catalog Overall Dimensions Meter Viewing Number Number Height Width Depth Doors Window Special Layout HC Single, Hinged -- For A Base Metering Fig HC Single, Hinged -- For A Base Metering Fig HC Single, Hinged 1, Hinged -- Fig DHC Single, Lift Off 3, Hinged -- Fig HC Single, Lift Off 1, Hinged w/ Pole Mount Brackets Fig HC Double, Hinged -- 3-Pt Latching Handle Fig. 5a HC Double, Hinged 1, Hinged 3-Pt Latching Handle Fig. 5b HC Double, Hinged 2, Hinged 3-Pt Latching Handle Fig. 5c Universal CT Equipment Mounting Racks Part/UPC Catalog Overall Dimensions Number Number Height Width H H 79

15 CT Utility Enclosures Layouts Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5a Fig. 5b Fig. 5c 80

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

Meter Mains - Without Bypass

Meter Mains - Without Bypass - 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat

More information

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment Single Meter Sockets, Without ypass -............................ 57-58 Meter Mains, With Optional MCC ypass -......................... 59-60 Meter Main Load Centers, With Optional MCC ypass -..........

More information

Multiple Metering, Horizontal Gang - Non Lever Bypass

Multiple Metering, Horizontal Gang - Non Lever Bypass Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground

More information

Multiple Metering, Vertical Gang

Multiple Metering, Vertical Gang Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or

More information

Meter Mains - With Optional MCC Bypass

Meter Mains - With Optional MCC Bypass Meter Mains - With Optional MCC ypass pplication Combination meter/main with optional manual circuit closing (link type) bypass Factory installed breaker Receive SI C12.10 watthour meters Surface mount

More information

Commercial Meter Pedestals

Commercial Meter Pedestals Metering Pedestals - Features & s............................ 109 Metering Pedestals - Base Details............................. 110 Metering Pedestals - Pad Mounted.........................................

More information

Instrument Rated Metering Equipment

Instrument Rated Metering Equipment Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions

More information

Cooper B-Line RESIDENTIAL SERVICES

Cooper B-Line RESIDENTIAL SERVICES RESIDENTIAL SERVICES Approved Voltage Optional Voltage w/utility Approval 011 011 5 th Clip 100 Amp Socket Only, Overhead 011F 011F 5 th Clip 100 Amp Meter Socket & Circuit 1M1R 1M1R 5 th Clip Breaker

More information

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

Meter Centers Meter Mounting Devices

Meter Centers Meter Mounting Devices Meter Mounting Devices General General Information Materials: 16 gauge, galvanized steel, G-90 Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

REC Municipal Meter Mounting Equipment

REC Municipal Meter Mounting Equipment REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

For vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed

For vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed Multiple Vertical APPLICATION For vertical multi-meter installations 1-6 meter positions esigned to receive watthour meters that meet ANSI C12.10 Overhead or underground feed CONSTRUCTION Type 3R construction

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Ohio Meter Mounting Equipment

Ohio Meter Mounting Equipment Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

Customer Requirements Meter Socket Configurations

Customer Requirements Meter Socket Configurations Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers

More information

CON EDISON EQUIPMENT

CON EDISON EQUIPMENT CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

Modular Metering Construction Details

Modular Metering Construction Details GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION

More information

Power Mod. Introduction.

Power Mod. Introduction. Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase

More information

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection .11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box

More information

Selection and Application Guide For use in New England EQUIPMENT

Selection and Application Guide For use in New England EQUIPMENT Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Meter Installation. -and- Padmount Transformer Guide

Meter Installation. -and- Padmount Transformer Guide Meter Installation -and- Padmount Transformer Guide Feb. 2016 METERING REQUIREMENTS The following information shall be used as a guide for installing metering equipment. A self-contained meter has all

More information

Lighthouse Power Pedestals,

Lighthouse Power Pedestals, Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized

More information

Single-Phase Ventilated

Single-Phase Ventilated Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -

More information

CABINET OPTIONS AND DESIGNATORS CODE LETTERS

CABINET OPTIONS AND DESIGNATORS CODE LETTERS CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

Power Mod. Standard Tapboxes.

Power Mod. Standard Tapboxes. Power Mod Standard tapbox modules (type WTB) are designed for versatility, space savings, and flexibility. Features include: J QuickSystem features J Standard compression lug capability J Invertibility:

More information

Selection and application guide

Selection and application guide Selection and application guide For use in Louisiana and Mississippi Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction

More information

Meter Mounting Equipment. GA/AL/FL Panhandle Area

Meter Mounting Equipment. GA/AL/FL Panhandle Area Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"

More information

Louisiana & Mississippi Area Catalog

Louisiana & Mississippi Area Catalog Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module

More information

Three-Phase Ventilated

Three-Phase Ventilated Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Type 4 Panel Enclosures

Type 4 Panel Enclosures Type 4 Free-Standing ata Sheet Finish Wash and phosphate undercoat ANSI 61 gray polyester powder finish Accessories Full and half panels Side and swing panels Channel mounting hardware Equipment rack mounts

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer

More information

Selection and application guide. For use in Ohio. Meter Mounting Equipment.

Selection and application guide. For use in Ohio. Meter Mounting Equipment. Selection and application guide For use in Ohio Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and general

More information

Louisiana/Mississippi. Area Catalog

Louisiana/Mississippi. Area Catalog Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Division 1 Explosionproof Panelboards

Division 1 Explosionproof Panelboards Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting

More information

ComEd Service Area Meter Mounting Equipment

ComEd Service Area Meter Mounting Equipment ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs

More information

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy

More information

Selection and application guide

Selection and application guide Selection and application guide For use in Pennsylvania and West Virginia Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page

More information

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,

More information

Selection and application guide

Selection and application guide Selection and application guide For use in Colorado and Wyoming Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction

More information

Indianapolis Power & Light Company

Indianapolis Power & Light Company Indianapolis Power & Light Company Electric Service and Meter Manual The Electric Service & Meter Manual is not copyrighted and permission is hereby given to reproduce this document. However, the Indianapolis

More information

Meter Centers & Loadcenters Group Metering

Meter Centers & Loadcenters Group Metering June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through

More information

General Specifications for Lighthouse Power Pedestal

General Specifications for Lighthouse Power Pedestal Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4

More information

Type 4 Panel Enclosures

Type 4 Panel Enclosures Wall-Mount Enclosures Type 4 Premier Series with Quarter-Turn Latches Data Sheet and Catalog Number Accessories Premier panels NEMA panel adapters Depth adjustment brackets Print pockets Padlockable or

More information

Type 4 Panel Enclosures

Type 4 Panel Enclosures Type 4 Lift-Off Cover ata Sheet Seamless poured in place gasket Application Houses electrical controls and instruments Intended for indoor or outdoor use Protects against windblown dust and rain, splashing

More information

Selection and application guide. For use in Texas. Meter Mounting Equipment.

Selection and application guide. For use in Texas. Meter Mounting Equipment. Selection and application guide For use in Texas Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and General

More information

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At

More information

American Electric Supply, Inc.

American Electric Supply, Inc. American Electric Supply, Inc. 6 S. Maple Street Date: 0/8/204 Corona, CA 92880 Telephone: 95-80-4665 Email: bmcdonald@amelect.com Fax: 95-552-626 Speedi Version: V 0.6 Valued Customer, Bill of Material

More information

(CT, NH, ME, RI, VT, MA)

(CT, NH, ME, RI, VT, MA) Selection and application guide For use in New England States (CT, NH, ME, RI, VT, MA) Meter Mounting Equipment www.talonmetering.com 1 Meter Mounting Equipment Table of Contents Service Rating Positions

More information

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection... .5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4

More information

High barriers Recognized by UL and cul Self-extinguishing materials Nonferrous material Corrosion-resistant nickel finish Safety-grip handle A complete line of switches is available for meter, relay, instrument,

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Selection and application guide

Selection and application guide Selection and application guide For use in New York State Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction

More information

Selection and application guide. For use in Kansas, Iowa, Missouri and Illinois. Meter mounting equipment.

Selection and application guide. For use in Kansas, Iowa, Missouri and Illinois. Meter mounting equipment. Selection and application guide For use in Kansas, Iowa, Missouri and Illinois Meter mounting equipment www.landisandgyr.com Contents Service Rating Positions Terminals Page Introduction and General Information

More information

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.

More information

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated

More information

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SECTION 500 METERING AND ASSOCIATED EQUIPMENT SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.

More information

Switchgear Skid, C1192

Switchgear Skid, C1192 CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts

More information

Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs

Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs Technical Information Sheet # 402 Subject: Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs Classified by Underwriters Laboratories to UL 2196 for one hour installations For

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER

More information

SPEEDFAX TM 2011 Meter Centers Contents

SPEEDFAX TM 2011 Meter Centers Contents SPEEDFAX TM 011 Meter Centers Contents Single and Multiple s - -19 General Information - -3 Single Position s - Residential Types -4-5 Multiple Position s Residential Types -6-7 Single Position s Commercial

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information