Meter Mounting Equipment Colorado Area
|
|
- Russell Grant
- 5 years ago
- Views:
Transcription
1 Meter Mounting Equipment Colorado Area
2
3
4
5 U80 PROFILE U8 Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and, also, complies with article in the NEC. To ensure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of 90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish. AMP TYPE MA H.P. TECHNICAL INFORMATION LINE & LOAD CONNECTOR ROUND CONNECTOR DIMENSIONS IRE RANE IRE RANE CU AL CU/AL D" " H" IRE RATIN CU C AL C 0 NONFUSIBLE U #4-# A #-# A #4-4 A /75 0 /75 0 FUSIBLE U8.5 #4-# A #4-# A #4- A / FUSIBLE U80 0. #4-# A #4-# A #4- A /75 0 /75 UL Listed as Enclosed Pullout Switch. Ø, 40 VAC. Type R Rainproof One-inch concentric knockouts
6 Combination AC Disconnect / 0 Amp FCI Receptacle Together in Box U8-0R AMP TYPE MA H.P. # AC DISCONNECT IRE RANE ROUND CONNECTOR IRE RANE CU AL CU/AL DIMENSIONS D" " H" IRE RATIN CU C AL C 0 NONFUSIBLE U8-0R 0 #4-# A #-# A #4-#4 A /75 0 /75 *Reprinted with permission from NFPA 70-00, National Electrical Code, Copyright 00, National Fire Protection Association, Quincy, MA 09. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, MA. Hot Tub Disconnect or Sub Panel Breaker Enclosure Type R Spa Box with FCI Protection Sub Panel Breaker Enclosure AMP TYPE # LINE CONNECTOR IRE RANE CU AL ROUND CONNECTOR IRE RANE CU/AL DIMENSIONS D" " H" 50 BREAKER U488-O-50B 8 #4-/0 #4-/0 #4-/ BREAKER U488-O-0B 8 #4-/0 #4-/0 #4-/
7 U8750-RL-KK U7487-RL-T-KK U90-RL-KK AMP 4 & 5 TERMINAL RINLESS TERM SERVICE HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' OH/U U7487-RL-T-KK H.O. #-/0 #-/0 HORN OH U8750-RL-KK H.O. #-/0 #-/0 HORN AMP 5 TERMINAL RESIDENTIAL RINLESS SERVICE HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U90-RL-T-KK H.O. #-50 #-50 HORN , 4 FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K for 5 amp unit. BYPASS: Horn type bypass is provided.
8 U59-O SERVICE AMP SINLE POSITION 4 TERMINAL RINLESS HUB U405-O CONNECTORS CU/AL DIMENSIONS 4 5 FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 o clock position. HUBS: For proper hub selection see the hub suffix chart on accessory page. CONNECTORS: Extruded aluminum connectors are tin plated CONCENTRIC KO'S D'' '' H'' 4 5 U U57-L C.P. # , AMP SINLE POSITION 4 TERMINAL SIDE IREAY RINLESS SERVICE HUB CONNECTORS CU/AL LINE LOAD DIMENSIONS CONCENTRIC KO'S D'' '' H'' 4 5 U U59-O BLANK 8- STUDS # , 00 AMP SINLE POSITION 4 TERMINAL RIN TYPE SERVICE HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S D'' '' H'' 4 5 U U405-O BLANK # , FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 o clock position. HUBS: For proper hub selection see the hub suffix chart on the accessory page. CONNECTORS: Extruded aluminum connectors are tin plated. SEALIN RINS: The above ring type units are supplied with an MR-4 screw type sealing ring as standard.
9 U985-RRL 00 AMP SINLE POSITION 4 TERMINAL RINLESS Ø SERVICE HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U985-RRL H.O. 8 x STUD 8 x STUD LEVER , FIFTH TERMINAL: For field installed fifth terminal order catalog number K8. May be installed in o clock or 9 o clock position. HUBS: For proper hub selection refer to the hub suffix chart on the Accessory page. LEVER BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Socket is supplied with /8 - hex head nuts with Belleville washers. For connector lug kits, order as extra from chart on page 0. Separate lug kits are required for line and load.
10 U980-RL SERVICE HUB U955-RRL U970-RL 00 AMP 4 TERMINAL RINLESS Ø FIFTH TERMINAL: For field mounted fifth terminal, order as extra K8. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units are supplied with extruded aluminum connectors and bonded neutral with a grounding stud CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U980-RL C.P. #-50 #-50 LEVER , AMP 5 TERMINAL RINLESS Ø OR Ø SERVICE HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U955-RRL H.O. #-50 #-50 LEVER , HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units supplied with extruded aluminum connectors, a bonded neutral and a grounding stud. FIFTH TERMINAL: Fifth terminal is supplied in the o clock position. Fifth terminal can be changed in the field from o clock to 9 o clock position. 00 AMP 7 TERMINAL RINLESS Ø4 SERVICE HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' 4 5 OH/U U970-RL C.P. #-50 kcmil #-50 kcmil LEVER , HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex ground. INSULATED NEUTRAL: For field installed insulated neutral, order kit number K047.
11 U480-L-5T U455-RRL U470-RRL 00 AMP 5 & 7 TERMINAL RINLESS Ø OR Ø TERM SERVICE HUB CONNECTORS CU/AL DIMENSIONS CONCENTRIC KO'S BYPASS LINE LOAD D'' '' H'' OH/U U480-L-5T9 C.P. #-50 #-50 LEVER , 5 OH/U U455-RRL H.O. #-50 #-50 LEVER , 7 OH/U U470-RRL H.O. #-50 #-50 LEVER , HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever bypass and the lever supplies clamping action on jaws. FACTORY-INSTALLED FIFTH TERMINAL: Includes factory installed fifth terminal in the 9 o clock position.
12 U AMP 4 & 7 TERMINAL SIDE IREAY RINLESS OH/U TERMS PHASE HUB CONNECTORS CU/AL LINE & LOAD FIFTH TERM KITS BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' U448- Ø C.P. 8"- STUD K85 LEVER U594- Ø4 C.P. 8"- STUD LEVER HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Stud type units supplied with /8 - hex head nuts with Belleville washers. For connector kits, order as extra: K59 (50 kcmil) or K540 (00 kcmil). For twin lug connectors order as extra: K50 (50 kcmil). For connector kits, order as extra: K08 (50 kcmil) or K44 (00 kcmil). For twin lug connectors, order as extra: K44 (#4-00 kcmil or () /0-50 kcmil). Separate kits are required for both line and load. FIFTH TERMINAL: Fifth terminal is available for field install.
13 U000-O-5T9-KL-KL KO right side only U779-RRL TERM SERVICE 0 AMP CONTINUOUS 4 & 5 TERMINAL HEAVY DUTY RINLESS 00 VAC HUB CONNECTORS CU/AL LINE BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' 4 5 HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The lever supplies clamping action and also operates bypass device. FIFTH TERMINAL: For field installed fifth terminal, order as extra K85. FACTORY-INSTALLED FIFTH TERMINAL: Includes factory installed fifth terminal in the 9 o clock position. LOAD #4-00 () 5 OH U779-RRL-5T9-K-K H.O. () #-50 LEVER , /0-50 () #4-00 () 5 U U000-O-5T9-KL-KL BLANK () #-50 LEVER , /0-50 () #4-00 () TIN 4 U U797-O-KL-KL BLANK LEVER , /0-50 () #-50
14 U5--K AMP / POSITION 4 TERMINAL RINLESS # OF POS. SERVICE HUB CONNECTORS CU/AL LINE LOAD DIMENSIONS CONCENTRIC KO'S D'' '' H'' 4 5 OH/U U5--K C.P. #-50 # OH/U U5--K C.P. #4-00 # () 4 4 U U54--K C.P #4-00 # (4) 4 5 U U55--K4 C.P () #-00 # (5) 4 U U5--K4 C.P () #-00 # () 4 HUB: For proper hub selection, refer to the hub suffix chart on the accessories page. For the U54- two hub openings are supplied and the extra opening is closed with a closing plate as standard. FIFTH TERMINAL: For field mounted fifth terminal for U5-, order catalog number K5T (9 o'clock position). CONNECTORS: Extruded aluminum connectors are tin plated. BUSSIN: Bussing is 5/" x " aluminum on the U5-5. On the U54- gangs, the bussing is /8" x " aluminum.
15 # OF POS. U854--HSP (Shown with circuit breakers order as extra) U8--HSP 5 AMP/POSITION 00 AMP/POSITION MAIN BUS RATIN LINE CONNECTOR SIZE U85--HSP 00 AMP * 8"- STUD U85--HSP 00 AMP * 8"- STUD # OF POS. VERTICAL RECTANULAR 5 AMP/POSITION 00 AMP/POSITION MAIN BUS RATIN LINE CONNECTOR SIZE 4 U854--HSP 400 AMP * 8"- STUD 5 U855--HSP 400 AMP * 8"- STUD # OF POS. # OF POS. MAIN BUS RATIN MAIN BUS RATIN LINE CONNECTOR SIZE U8--HSP 50 AMP * 8"- STUD U8--HSP 00 AMP * 8"- STUD LINE CONNECTOR SIZE 4 U84--HSP 400 AMP * 8"- STUD 5 U85--HSP 00 AMP * 8"- STUD U85--HSP 400 AMP * 8"- STUD U8--HSP 00 AMP * 8"- STUD U85-U85 PLU-IN BREAKER COMPATIBILITY CHART U8-U8 CUTLER HAMMER SIEMENS SIEMENS/ MURRAY.E. SQUARE D CUTLER HAMMER SIEMENS SIEMENS/ MURRAY.E. SQUARE D 5 Quicklag P / BR QP MP QLine Homeline 5-00 BR, BJ QN MD QLine Quicklag P, 5 QP MP QLine Homeline BR, HQP CONNECTOR KITS * SIZE SUFFI KIT # COMPATIBLE ITH SINLE TIN IRE RANE -K K59 U85-5, U8- #-50 kcmil -K K540 U854-5, U84- #4-00 kcmil -K K50 U854-5, U8- #-50 kcmil -K4 K54 U84- #-00 kcmil *CONNECTORS: For line wire connector kits, order separately. Order kit per bank. FIFTH TERMINALS: For field mounted fifth terminal order catalog number K8. Order one per meter position. BREAKERS: Units have provision for one double pole main per meter position. Breakers not included. Order as extra.
16 # OF POS. U474-T-5T9 00 AMP/POSITION MAIN BUS RATIN LINE CONNECTOR SIZE U47-T-5T9 0 AMP 8"- STUD U47-T-5T9 480 AMP 8"- STUD 4 U474-T-5T9 40 AMP 8"- STUD 5 U475-T-5T9 40 AMP 8"- STUD U47-T-5T9 40 AMP 8"- STUD PLU-IN BREAKER COMPATIBILITY CHART CUTLER HAMMER SIEMENS SIEMENS/ MURRAY.E. SQUARE D 5-00 BR, BJ QN MD QLine Quicklag P, 5 QP MP QLine Homeline BR, HQP LINE SIDE CONNECTOR KITS * SIZE SUFFI KIT # COMPATIBLE ITH SINLE TIN IRE RANE -K K59 U47-7 #5-50 kcmil -K K540 U474-7 #4-00 kcmil -K K50 U47-7 #-50 kcmil -K4 K54 U474-7 #-00 kcmil *CONNECTORS: For line side connector kits, order separately. BREAKERS: Units have provision for one double pole main per meter position. Breakers not included. Order as extra. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. FIFTH TERMINAL: Factory installed in 9 o clock position.
17 00 AMP/POS. (- POSITION) 7 /4" 00 AMP/POS.(4,5 & POSITION) 48" or 0" K.O. DIMENSIONS,, CONCENTRIC K.O., 4,, CONCENTRIC K.O. 4, CONCENTRIC K.O. 0" 48" 45"
18 U58-TL # OF CIRCUITS 4 TERMINAL METER MAIN OVERHEAD/UNDERROUND K AIC Ø HUB CONNECTORS CU/AL LINE LOAD BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' U58-TL-00-KK C.P. #-50 #/0-00 HORN 4 4 8, 4,, 4 Breaker* 50 8 U58-TL-50-KK C.P. #-50 #/0-00 HORN 4 4 8, 4,, 4 Breaker* 00 8 U58-TL-00-KK C.P. #-50 #/0-00 HORN 4 4 8, 4,, 4 Breaker* 50 0 U58-TL-50-KK C.P. #-50 Breaker HORN 4 4 8, U58-TL-00-KK C.P. #-50 Breaker HORN 4 4 8, 4 HUB: Supplied with () closing plates packed inside. Order hubs as a separate item. See accessory page for hub options. INTERIOR: U58 units have 8 circuit interior; U58 units have 0 circuit interior. FIFTH TERMINAL: Order K5T and field install for 08Y/0 network systems. Installs in the 9 o clock position only. BREAKERS: Rated K AIC with Milbank QNR00H main installed. INTERLOCK KIT: For generator auxiliary circuit breaker interlock, order K585 for large QN with small frame Q; order K580 for large frame QN with large frame QN; order K580 for small frame Q with small frame Q. *SUB-FEED LUS: #-50 kcmil sub-feed lugs provided on 8 circuit interior. Not available on 0 circuit interior., 4,, 4, MAIN CIRCUIT BREAKER CHART Amperage 50A - K 00A - K Catalog No. QN50RH QN00RH
19 U58-TL / 00 AMP 5 TERMINAL METER MAIN K AIC 0/40 VOLT Ø RINLESS / RIN TYPE OVERHEAD / UNDERROUND 8 CIRCUIT INTERIOR AMP CIRCUITS HUB CONNECTORS CU/AL LINE BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' U58-TL-50-KK-5T C.P. #-50 HORN 4 4 8, U58-TL-00-KK-5T C.P. #-50 HORN 4 4 8, 4 HUB: Supplied with () closing plates packed inside. Order hubs as a separate item. See accessory page for hub options. INTERIOR: U58 units have 8-circuit interior; U58 units have 0-circuit interior. FIFTH TERMINAL: Order K5T and field install for 08Y/0 network systems. Installs in the 9 o clock position only. BREAKERS: Rated K AIC with Milbank QNR00H main installed. INTERLOCK KIT: For generator auxiliary circuit breaker interlock, order K585 for large QN with small frame Q; order K580 for large frame QN with large frame QN. SUB-FEED LUS: #-50 kcmil sub-feed lugs provided on 8 and 0 circuit interior., 4,, 4,
20 U587-L-00 4 TERMINAL RINLESS AMP SERVICE HUB CONNECTORS CU/AL LINE LOAD BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' OH/U U587-L-00* C.P. #-50 CB* LEVER 4 4 8, 4 4, 00 OH/U U587-L-00** C.P. #-50 CB LEVER 4 4 8, 4 4, RATIN kaic 0 MAIN SIEMENS: QNR, QNRH SIEMENS: QNRH CIRCUIT BREAKERS BRANCH SIEMENS: QP, QPH CUTLER-HAMMER: BR, BRH, HPQ, QPH, QPF, QPHF SQUARE D: HOMELINE.E.: (50 AMP MA) THQL, THHQL, THQL-F, THHQL-F SIEMENS: QP, QPH BREAKERS: Rated K AIC with Milbank QNR00H main installed. BRANCH BREAKERS: () single-pole branch circuits available. FIFTH TERMINAL: Order K5T and field install for 08Y/0 network systems. Installs in the 9 o clock position only. INTERLOCK KIT: For generator auxiliary circuit breaker interlock, order K585 for large QN with small frame Q; order K580 for large frame QN with large frame QN. * 8 circuit load center with sub-feed lugs. ** 0 circuit load center
21 0 AMP CONTINUOUS 400 AMP MA U40-O-/00 U5059--/00-KL AMP METER MAIN ITH BREAKERS SIDE IREAY RINLESS 0/40 VAC SERVICE HUB CONNECTORS CU/AL LINE LOAD FIFTH TERM KITS BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' 4 5 OH/U U5059--/00-KL* C.P. #4-00 /0-00 K8 LEVER , OH/U U5059--KL** C.P. #4-00 K85 LEVER , U U40-O-/00* BLANK 8" x STUDS /0-00 K8 LEVER , LEVER BYPASS: Lever supplies clamping action and operates bypass device. CONNECTORS: U40 socket is supplied with /8 - hex head nuts with Belleville washers. For connector lug kits, order as extra from chart on accessory page. Lug kit required for line side only. *BREAKERS: Supplied with () bolt-in Milbank UQFBH-00 breakers. Rated at K AIC. **Requires UQFPH- breakers sold separately.
22 UC48-L-TS08005 (with test switch factory installed) 4 RIN TYPE ITH PROVISIONS FOR TEST SITCH EUSERC COMPLIANT TO PIECE FRONT # OF TERMS 5 OH/U UC45-L C.P. #4 - # NONE OH/U UC4-L C.P. #4 - # NONE OH/U UC48-L C.P. #4 - # NONE OH/U UC4-L C.P. #4 - # NONE OH/U UC44-L C.P. #4 - # NONE # OF TERMS SERVICE SERVICE HUB RINLESS PREIRED TEST SITCH ITH COVER HUB CONNECTORS CONNECTORS OH/U UC9-RL-C- H.O. #4 - # TEST SITCH OH/U UC445-RL-C- H.O. #4 - # TEST SITCH BYPASS BYPASS DIMENSIONS D'' DIMENSIONS D'' '' '' 4 5 H'' H'' CONCENTRIC KO'S CONCENTRIC KO'S *SEALIN RINS: Ring type units are supplied with one MR-4, screw type, sealing ring. PREIRIN: If factory prewiring is required consult factory before ordering. Please include meter socket catalog number, test switch number, meter form number, and a copy of your wiring diagram. See page 4. TEST SITCH COVERS: Units on this page can be used with clear lexan cover order K88 for field-installable cover. CONNECTORS: Units are supplied with sleeve type connectors (#4-#) HUBS: For proper hub selection see the hub suffix chart in accessory section. Provided with clear lexan test switch cover and factory installed / pre-wired test switch.
23 P C C KEY Potential Switch Line side current switch with short circuit assembly Load side current switch with test jack assembly TS04-00 TS / 7 /" / 9 /" 4-POLE P Pn C C C C P Pn N Neutral bar ( no switch ) Pn Neutral potential switch 7-POLE Unused position on base Insulating barrier, isolates both sides of switch TS P P Pn C C C C CUSTOM POLE ARRANEMENTS: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply. TS TS POLE ON A 0 POLE BASE P P Pn C C C C P C C P C C Pn 0-POLE STANDARD COVER TS0-009 P P P Pn C C C C C C TS0-00 P C C P C C P C C Pn TS0-0 P P P Pn C C C C C C TS0-0 C C C C C C P P P Pn K88 TS0-00 P P P PN C C C C C C
24 BK Black P Purple R BR Red Brown BL R Blue rey Y O Yellow hite Orange N reen BKS BK/Stripe S /Stripe P C C KEY Potential Switch Line side current switch with short circuit assembly Load side current switch with test jack assembly N Neutral bar ( no switch ) Pn Neutral potential switch Unused position on base Insulating barrier, isolates both sides of switch
25 U4-O STABILIZER FOOT 0" 5 /" 4 /8" " " 55" U4 & U4 PLU-IN BREAKER COMPATIBILITY CHART MILBANK CUTLER- HAMMER (ESTINHOUSE) SIEMENS (ITE) SIEMENS MURRAY/ CROUSEHINDS 00 AMP 4 TERMINAL RINLESS.E. U4-O SQUARE D 5-00 Q, QN HQP, BR, BJ QN MD QLine Quicklag P, 00 Q QP MP QLine Homeline BR, HQP METER POSITIONS BYPASS MOUNTIN TYPE TIN LINE CONNECTORS CU/AL CIRCUIT PROV. U4-O-(AMP) SINLE LEVER POST # A-50 U4-O-(AMP) DOUBLE LEVER POST # A-50 CONCENTRIC KO'S Provisions for Main with Branch or Parallel Breakers LEVER BYPASS: Lever provides clamping action on meter spades and also operates bypass device. APPLICATION: The U4 & U4 pedestals are suitable for use as service equipment or mobile home service equipment. K508 / K88 for direct burial application is included with unit. K55 for pad mount application must be ordered as extra. BREAKERS: These units are wired as parallel mains and have provisions for six circuits: six single-pole or three double-pole breakers. Quadplex style breakers may be used in accordance to the NEC. If main breaker is used, there are provisions for two -pole breakers or four -pole breakers in series. FIFTH TERMINAL: For field installed fifth terminal order catalog number K85 (neutral wire not provided) or K8 (with neutral wire). Both may be installed in o clock or 9 o clock position.
26
27
28 Stock item availability subject to prior sale. Non-stock items minimum order quantity required.
29 U509-RL-7BR 5 AMP 5 TERMINAL POER OUTLET RINLESS 0/40 VAC Ø TERMS SERVICE HUB CONNECTORS CU/AL LINE BYPASS DIMENSIONS CONCENTRIC KO'S D'' '' H'' OH U509-RL-7BR H.O. #-50 LEVER BREAKERS: U509 is factory wired with two () 0 amp / 0V breakers and one () 50 amp / 0-40V FCI breaker. RECEPTACLES: U509 includes two () factory installed 0 amp / 0V duplex FCI receptacles and one () 50 amp / 0-40V receptacle. BY-PASS: Lever supplies clamping action on meter spades and also operates bypass device. FIFTH TERMINAL: Includes factory installed fifth terminal at 9 o clock.
30 Un-Strut Your Stuff... Commercial Pedestals
31
32 SINLE For use with /8 - stud type units only TIN TIN CONNECTOR KITS SUFFI CAT # ( per set) - Ø K K59-50 kcmil K K kcmil or () /0-50 kcmil KL K540L 4-00 kcmil or () /0-50 kcmil SUFFI CAT # (4 per set) - Ø K5 K08-50 kcmil K7 K kcmil or () /0-50 kcmil SUFFI CAT # ( per set) - Ø K K50-50 kcmil KL K50L 4-00 kcmil Non-rotating K4 K kcmil SUFFI CAT # (4 per set) - Ø K K44-50 kcmil K8 K kcmil LOAD TAP CONNECTORS ( per set) Replaces the load side slide-in nut assembly on Milbank 00 amp sockets. Allows for a 00 amp tap location in addition to the #-50 kcmil load-side connector. K50 Includes Safety Barrier Extensions for applications over 00 VAC in Heavy Duty block. K4977-INT INTERNAL HE K50-INT INTERNAL HE INTERCHANEABLE UNIT HUBS HUB ADAPTER PLATE (Converts 4" opening to ") S84 HUB ADAPTER PLATE DESC. SUFFI CAT. # HUB ADAPTER -RRL S84 REMOVABLE HUB CLOSIN PLATE DESC. SUFFI CAT. # SMALL -L A755 (for -RL opening) LARE - A904 (for -R opening) SMALL "RL" OPENIN (STANDARD) SUFFI SIZE MILBANK # L " A754 YL 4" A755 ZL " A75 DL " A757 EL " A758 LARE "RL" OPENIN (HEAVY-DUTY) SUFFI SIZE MILBANK # F " A80 " A8 H 4" A8 O RL R L RL RRL T L YL ZL DL EL F H TOP SUFFI CHART Plain Top Small Hub Opening Large Hub Opening Small Closing Plate Large Closing Plate Large hub opening adapted small closing plate Large hub opening adapted to small hub opening Twin Large hub opening with closing plates HUB SUFFI CHART " For -RL Opening 4" For -RL Opening " For -RL Opening " For -RL Opening " For -RL Opening " For -R Opening " For -R Opening 4" For -R Opening METER CLOSIN PLATE (Ring type / Ringless) 00 (ray Plastic) (Clear Plastic) METAL CLOSIN PLATE (For Ringless sockets): CP- TRIPLE ROUND (K90) (For factory installed triplex ground add suffix -T to the catalog number.) DISCONNECT SLEEVE * M5-44 (*NOT TO BE USED ITH LEVER BYPASS SOCKETS) TOUCH-UP PAINT
33 FIFTH TERMINALS Consult factory for 5th terminal selection SEALIN RINS amp PLU-IN FIFTH TERMINAL 5T8K BYPASS LINK (K880) (Bypass links sold in pairs) SNAP ACTION MR- 00 amp FIFTH TERMINAL K5T (New style block with square hole) ISOLATED NEUTRAL KIT (K047) *HEAVY DUTY FIFTH TERMINAL (K85) (K8 without neutral wire) *Both kits for units manufactured after August, 99 SCRE TYPE (Stainless Steel) MR-4 ANTI-INVERSION CLIP (K480) BREAKER COMPATIBILITY CHART* MILBANK CUTLER- HAMMER (ESTINHOUSE) SIEMENS (ITE) SIEMENS MURRAY/ CROUSEHINDS.E. SQUARE D 5-00 Q, QN HQP, BR, BJ Q, QN MD QLine Quicklag P, 00 Q QP MP QLine Homeline BR, HQP *Contact your local Milbank rep for breaker compatibility.
34 UQFP UQFPH UQFP-M UQFPH-M 00 AMP FRAME PLU-IN 0,000 AIC &,000 AIC TO-POLE COMMON TRIP 0K AIC K AIC 0K AIC K AIC IRE RANE PLU-IN PLU-IN PLU-IN PLU-IN CU AL 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 #-# #-/0 5 UQFP-5 UQFPH-5 UQFP-M-5 UQFPH-M-5 #-# #-/0 50 UQFP-50 UQFPH-50 UQFP-M-50 UQFPH-M-50 /0-00 / UQFP-75 UQFPH-75 UQFP-M-75 UQFPH-M-75 /0-00 / UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 /0-00 /0-00 UL LISTED: For use with 0 C or 75 C wire. UQFP: For parallel main circuit breaker applications UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. STANDARD PACKAIN: 5 units per lb. carton.
35 UQFB- UQFB- UQFB UQFB--MOD 00 AMP FRAME BOLT-ON 0K AIC & K AIC TO-POLE COMMON TRIP 0K AIC K AIC 0K AIC IRE RANE BOLT-ON BOLT-ON BOLT-ON CU AL 00 UQFB-00 UQFBH-00 UQFB-00- #-# #-/0 5 UQFB-5 UQFBH-5 UQFB-5- #-# #-/0 50 UQFB-50 UQFBH-50 UQFB-50- /0-00 / UQFB-75 UQFBH-75 UQFB-75- /0-00 / UQFB-00 UQFBH-00 UQFB-00- /0-00 /0-00 UL LISTED: For use with 0 C or 75 C wire. UQFB: () /0-00 kcmil lugs provided on load and line side (cable-in, cable-out.) UQFB: Three pole available. Consult factory. UQFB-: () /0-00 kcmil lugs provided on load side and () line bar bus connections on line side. UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. UQFB--MOD: Replacement circuit breaker with line barriers removed. STANDARD PACKAIN: 5 units per lb. carton.
36 TYPE RH & RHH (without outer covering) TH T TH FEPB ( thru ), RH and RHH (without outer covering) RH, THH MAIMUM OF CONDUCTORS IN CONDUIT* CONDUCTOR SIZE A,MCM CONDUIT TRADE SIZES (INCHES) /0 /0 /0 4/ *This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C A /0 /0 /0 4/ *CU B AL or Cu-Clad AL A /0 /0 /0 4/ C * Allowable ampacities of insulated Copper & Aluminum conductors ( in conduit) 75 C (7 F) Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk ( ) shall not exceed 5 amps for 4 A, 0 amps for A, and 0 amps for 0 A copper: or 5 amps for A and 5 amps for 0 A aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 99 N.E.C. Manual article 0- and ANSI / UL-44 (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 75 C insulated wire conductor, sized in accordance with Table 0- of the National Electric Code. AN SOCKET OVERALL AMPACITIES NO. OF METER POSITIONS A / POS. AMPACITY 00A 00A 00A 5A 70A 5A / POS. AMPACITY 00A 5A 50A 85A 0A 50A / POS. AMPACITY 00A 5A 70A 8A 9A 00A / POS. AMPACITY 00A 70A 0A 450A 58A AMPACITY CORRECTION FACTORS AMBIENT TEMP.C A = Size: A/MCM B = Ampere Rating for Insulation Types: FEP, RH, RH, TH, THN, HH, USE,. C = Ampere Rating for Insulation Types: RH, RH, TH, THN, HH, USE (Per NEC table 0-) CORRECTION FACTOR AMBIENT TEMP.F All meter sockets are 00 volt rated unless otherwise noted. All meter socket ampacity ratings are continuous duty unless otherwise noted.
37 In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. A. ive equipment a thorough visual examination to determine that: ) No shipping or installation damage exists. ) Proper clearances have been maintained. ) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to: ) Verify tightness of all bolted connections (see table below). ) Manually operate all circuit breakers, switches, relays, etc. ) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization. A. Use caution and follow established safety procedures: ) ear safety apparel. ) Use safety equipment. ) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. A. Secure the installation: ) To prevent accidental contact with energized parts, cover all openings with approved filler devices. ) To prevent unauthorized access, secure all covers and/or doors with approved security devices. ) Attach/post information to advise others of potential hazards associated with the installation. NOMINAL SIZE /4 /4 5/ RECOMMENDED TORQUE FOR ENERAL APPLICATIONS* SCRE BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL JOINT DESCRIPTION NUT Brass Nut or Extruded Hole CU or AL Busbar </8 Steel Nut or EH; CU or AL Busbar >/8 Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole HEAD TYPE ALL ALL ALL ALL ALL ALL ALL HE TORQUE ( INCH LBS. ) 0-5 in. lbs. 5-0 in. lbs 0-5 in. lbs 0-5 in. lbs in. lbs in. lbs in. lbs in. lbs. 5/ STEEL Steel Nut or EH; CU or AL Busbar HE in. lbs. /8 STEEL Steel Nut HE in. lbs. / STEEL Steel Nut HE in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum
38 MATERIALS STEEL QUALITY The meter equipment listed in this catalog is made of galvanized steel (AISI* 90) to afford the best possible weather proofing. *American Iron and Steel Institute. STEEL SHEET gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. (AISI 90) 4 gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. ALUMINUM ETRUSION ire-terminals: Alloy; 0-T, Tin-plated for CU/AL wire. Bus Bar: Alloy; 0-o & 0-O ALUMINUM SHEET 000 series aluminum sheet, H4, or 505 series aluminum sheet, H. here applicable thicknesses range from.04.5 COPPER SHEET & BUS Electrolytic copper with tin plating in most applications. INSULATIN MATERIALS FINISH reinforced high-strength, track resistant, thermoset polyester molding compounds. resistant, polycarbonate molding compounds. fabrication of flat, formed and punched component parts and barriers. RATIN PROCESS Light gray state of the art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. METAL FASTENERS Zinc-coated with a chromate dip. NEMA RATIN Milbank meter sockets, CT cans and meter socket / breaker units have a type R rating.
39 DIARAM A with P.T. & C.T. Single Stator Meter( ) - Form S 5T Socket, Test Switch #TS04-00 DIARAM A DIARAM B with C.T. Single Stator Meter( ) - Form S 5T Socket, Test Switch #TS04-00 DIARAM B DIARAM C with C.T. s Single Stator Meter( ) - Form 4S T Socket, Test Switch #TS DIARAM C DIARAM D or Network with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIARAM D (ALT.LOC.) (ALT.LOC.) P PN C C P PN C C P P C C C C P P C PN C C C P.T. I LINE N (BONDED) C.T. LOAD DIARAM E with P.T. s & C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS I LINE N (BONDED) C.T. LOAD DIARAM F with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS I LINE N (BONDED) C.T. C.T. LOAD DIARAM 4 Y with C.T. s Stator Meter - Form S T Socket, Test Switch #TS0-009 I LINE N (BONDED) C.T. C.T. LOAD DIARAM H 4 Y with P.T. s & C.T. s Stator Meter - Form S T Socket, Test Switch #TS0-009 DIARAM E DIARAM F DIARAM DIARAM H P P PN C C C C C C P P PN C C C C C C P P P C C C C P P P C C C C LINE PT PT C.T. C.T. LOAD DIARAM I 4 Y or with C.T. s Y Stator Meter - Form 9S Stator Meter - Form 8S T Socket, Test Switch #TS0-009 LINE C.T. C.T. LOAD DIARAM J 4 Y with P.T. s & C.T. s Stator Meter - Form 9S T Socket, Test Switch #TS0-009 LINE N (BONDED) C.T. LOAD C.T. C.T. LINE N PT PT (BONDED) C.T. LOAD C.T. C.T. DIARAM I DIARAM J P P P PN C C C C C C P P PN C P C C C C C PREIRIN: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. LINE N (BONDED) C.T. LOAD C.T. C.T. PT PT PT LINE N (BONDED) C.T. C.T. LOAD C.T.
40 SC SC TR TR TR and -IRE FORMS S & S and -IRE FORMS S & S with BYPASS -IRE FORM S 5th Term. 9 o'clock -IRE FORM S with BYPASS -IRE FORM S 5th Term. o'clock TR SC SC SC SC -IRE FORM S with BYPASS ELEMENT -IRE NETORK FORM S 5th TERM. 9 o'clock ELEMENT -IRE NETORK FORM S with BYPASS 5th Term. 9 o'clock ELEMENT -IRE NETORK FORM S 5th TERM. o'clock ELEMENT -IRE NETORK FORM S with BYPASS 5th Term. o'clock TR TR SC SC TR -IRE FORM 4S -IRE FORM 4S ITH BYPASS or ELEMENT 4 Y or Y FORM 4S FORM 5S or ELEMENT 4 Y or FORMS 4S & 5S with BYPASS ELEMENT 4 Y or Y FORM 7S FORM 4S with BYPASS TR TR SC SC TR ELEMENT, 4, FORM 5S ELEMENT, 4, FORM 5S with BYPASS ELEMENT, 4, FORM S or ELEMENT, 4, FORM S with BYPASS or ELEMENT 4 Y or Y FORM 9S FORM 8S TR = TRANSFORMER RATED SC = SELF CONTAINED TR TR TR or ELEMENT 4 Y or FORMS 8S & 9S with BYPASS ELEMENT 4 Y FORM S ELEMENT 4 Y FORM S with BYPASS
41 POLE IRE ROUNDIN RECEPTACLES VOLTS CODE 5V 5 50V 77 VAC 7 STRAIHT BLADE IRIN DEVICES POLE IRE SPECIAL APPLICATIONS 50 TIST-LOCK IRIN DEVICES R 5-0R 5-0R 5-50R L5-5R L5-0R L5-0R -5R -0R -0R -50R L-5R L-0R L-0R 7-5R 7-0R 7-0R 7-50R L7-5R L7-0R L7-0R Y Y Y STRAIHT BLADE IRIN DEVICES TIST-LOCK VOLTS CODE V 50V 0 Y Y Y Y Y 0-0R 0-0R 0-50R L0-0R L0-0R POLE 4 IRE ROUNDIN STRAIHT BLADE IRIN DEVICES TIST-LOCK VOLTS CODE V 50V 4 Y Y Y Y Y Y 4-5R 4-0R 4-0R 4-50R L4-0R L4-0R POLE IRE ROUNDIN NEMA TRAILER STRAIHT BLADE VOLTS CODE 0 5V TT TT-0R
42 cel Energy City of Colorado Springs Pacific Power SKU MPRV-00-0R-78 MPRV MPRV-00-MB-78 MPRV-5000R-78 MPRV MPRV-BLANK-78 MPRV-BLANK-78-R-5T U5--KK U5--KK-K U5--KK U5--KK-K U54--KK U54--KK-K U55--KK U55--KK-K U5--KK U5--KK-K4 U57-L U779-RRL-5T9-KL-KL U797-O-KL-KL U594- U85--KK U85--KK U854--KK U855--KK U85--KK U8--KK U8--KK U85--KK U8--KK U000-O-5T9-KL-KL U405-O U40-O-/00 U4-O U4-O U47-T-5T9 U47-T-5T9 U474-T-5T9 U475-T-5T9 Aquila Longmont City cel Energy City of Colorado Springs Pacific Power Aquila Longmont City SKU U47-T-5T9 U448-T U455-RRL U470-RRL U480-L-5T9 U5059--/00-KL U509-RL-7BR U5-O U5-O-00S U5-O-00S U57-O U57-O-00S U57-O-00S U58-O U58-O-00S U58-TL-00-KK U58-TL-00-KK-5T U58-TL-50-KK U58-TL-50-KK-5T U58-TL-00-KK U58-TL-50-KK U58-TL-00-KK U570-O-5T9 U570-O-5T9 U587-L-00-5T9 U587-L-50-5T9 U587-L-00-5T9 U587-L-50-5T9 U587-L-00-5T9 U7487-RL-T-KK U8750-RL-KK U90-RL-T-KK U955-RRL U970-R U970-RL U980-RL UC9-RL-C- UC445-RL-C-
43 SKU Page # SKU Page # SKU Page # SKU Page # J...0 5T8K... A A A75... A A A A80... A8... A8... A A-P... CP-PDMNT-CALT...0 CP-... CP-4PDMNT-CALT...0 CP-ABK5/8...0 CP-PE-HOA-POS...0 CP-TC4H...0 CP-TC7D...0 CP-TCIRE...0 K K90... K50...4,5, K50L... K59...4,5, K ,5, K540L... K54...4,5, K08... K08... K44... K44... K K85...0, K K4977-INT... K50-INT... K K K K K K R...7 K5400-BRIDE-POS...7 K5400-BRIDE-POS...7 K5400-TT0...7 K K5T...7, K M MCP... MR-... MR-SS... MR-4... S84... TS TS TS TS TS TS TS TS TS TS U5--K... U5--K... U54--K... U55--K4... U5--K4... U57-L...7 U779-RRL-5T9-KL-KL. U797-O-KL-KL... U U59-O...7 U U85--HSP...4 U85--HSP...4 U854--HSP...4 U855--HSP...4 U85--HSP...4 U8--HSP...4 U8--HSP...4 U84--HSP...4 U85--HSP...4 U8--HSP...4 U000-O-5T9-KL-KL... U U8-0R...5 U8...4 U U405-O...7 U40-O-/ U4-O...4 U4-O...4 U47-T-5T9...5 U47-T-5T9...5 U474-T-5T9...5 U475-T-5T9...5 U47-T-5T9...5 U455-RRL...0 U470-RRL...0 U480-L-5T9...0 U488-O-50B...5 U488-O-0B...5 U5059--/00-KL...0 U T9-KL...0 U509-RL-7BR...8 U5-O...7 U5-O-00S...7 U5-O-00S...,7 U57-O...7 U57-O-00S...7 U57-O-00S...7 U58-O...7 U58-O-00S...7 U58-TL-00-KK...7 U58-TL-50-KK...7 U58-TL-50-KK-5T...8 U58-TL-00-KK...7 U58-TL-00-KK-5T...8 U58-TL-50-KK...8 U58-TL-00-KK...7 U587-L U587-L U7487-RL-T-KK... U8750-RL-KK... U90-RL-T-KK... U955-RRL...9 U970-RL...9 U980-RL...9 U985-RRL...8 UC4-L... UC44-L... UC45-L... UC4-L... UC48-L... UC9-RL-C-... UC445-RL-C-... UQFB UQFB UQFB UQFB UQFB UQFB UQFB UQFB UQFB UQFB UQFBH UQFBH UQFBH UQFBH UQFBH UQFP UQFP-5... UQFP UQFP UQFP UQFP-M UQFP-M-5... UQFP-M UQFP-M UQFP-M UQFPH UQFPH-5... UQFPH UQFPH UQFPH UQFPH-M UQFPH-M-5... UQFPH-M UQFPH-M UQFPH-M-00...
44 In addition to your local utility s meter mounting equipment, Milbank also manufactures supporting products, such as... Contact your local distributor or go to: to find additional product literature. Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches
45
46
47
48 Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches DELANDSHEER SALES 0. 4th Avenue Denver, CO 80 Tel: Fax: MILBANK MF. CO. PO Box 4908 Kansas City, MO Tel: Fax: Toll Free: COLO 8/0 (K)
Meter Mounting Equipment Colorado Area
Meter Mounting Equipment Colorado Area milbank overview milbank overview Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. aldrop, 9-00 Robert F. aldrop, II Chairman Katrina aldrop Henke Vice Chairman
More informationMeter Mounting Equipment DTE Energy Area
Meter Mounting Equipment DTE Energy Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationMEG Approval Meter Equipment Group
MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationDuke/MEG Approval Meter Equipment Group
Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides
More informationNew England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that
More informationMeter Mounting Equipment. Northern Indiana Public Service Co.
Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop
More informationComEd Service Area Meter Mounting Equipment
ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs
More informationREC Municipal Meter Mounting Equipment
REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationOhio Meter Mounting Equipment
Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures
More informationIndiana Meter Mounting Equipment
Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationWisconsin Area Catalog
Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationMeter Mounting Equipment Wisconsin Area
Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationLouisiana/Mississippi. Area Catalog
Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At
More informationMeter Mounting Equipment Florida Area Catalog
Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert
More informationNew Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment
New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work
More informationConsolidated Edison Orange & Rockland Meter Mounting Equipment
Consolidated Edison Orange & Rockland Meter Mounting Equipment 2 MILBANK OVERVIE Milbank Overview Energy At ork since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationUpstate New York Meter Mounting Equipment
Upstate New York Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIE Milbank Overview Energy At ork since 97 Milbank builds
More informationMeter Mounting Equipment Commonwealth Edison
Meter Mounting Equipment Commonwealth Edison MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice
More informationPennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog
Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy
More informationMeter Mounting Equipment. GA/AL/FL Panhandle Area
Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke
More informationMeter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market
Meter Mounting Equipment Arkansas, W. Tennessee, N. Mississippi Market MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman
More informationMeter Mounting Equipment
Meter Mounting Equipment Central Hudson Service Area New York State Electric & Gas Service Area National Grid NY Service Area Rochester Gas & Electric Service Area MILBANK OVERVIEW MILBANK OVERVIEW Charles
More informationtot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,
' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.483.534 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy
More informationInstrument Rated Metering Equipment
Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions
More informationLouisiana & Mississippi Area Catalog
Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationTennessee Area Meter Mounting Equipment
Tennessee Area Meter Mounting Equipment MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationPSE&G Long Island Meter Mounting Equipment
PSE&G Long Island Meter Mounting Equipment Milbank Overview Energy At Work since 927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential,
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More informationEquipment. Metering. Metering Equipment 1. Contents
1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................
More informationCT Metering. CT Metering. Meter Mounting Equipment
Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination
More informationEquipment. Metering. Metering Equipment 1. Contents
1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationSelection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting
Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -
More informationModular Metering Application Guide
GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III
More informationModular Metering Construction Details
GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals
Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents
More informationSelection and Application Guide For use in New England EQUIPMENT
Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,
More informationMP Meter-Pak Meter Centers
Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application
More informationCP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long
More informationDesign Standard. Purpose: Design Standard:
Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal
DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)
More informationRMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities
RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue
More informationBussmann series Quik-Spec Coordination Panelboard
Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationMultiple Metering, Horizontal Gang - Non Lever Bypass
Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground
More informationMeter Centers & Loadcenters Group Metering
June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationGroup Meter Main - Without Bypass
100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included
More informationMetering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering
Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center
Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationSingle Socket and Horizontal Metering
Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential
More informationCustomer Requirements Meter Socket Configurations
Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements
More informationSPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents
SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 WireGuide Load Centers and Breakers -4 PL Series Load Centers Features
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationSelection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting
Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More informationSelection and Application Guide. Meter Mounting Equipment. For use in Iowa and Nebraska.
Selection and Application Guide Meter Mounting Equipment For use in Iowa and Nebraska www.talonmetering.com Meter Mounting Equipment Table of Contents Air Conditioning Disconnects Fused and Non-fused Rating
More information(CT, NH, ME, RI, VT, MA)
Selection and application guide For use in New England States (CT, NH, ME, RI, VT, MA) Meter Mounting Equipment www.talonmetering.com 1 Meter Mounting Equipment Table of Contents Service Rating Positions
More informationQuik-Spec Electrical Gear
Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals
Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41
More informationMeter Centers Meter Mounting Devices
Meter Mounting Devices General General Information Materials: 16 gauge, galvanized steel, G-90 Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More information6.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................
More informationMultiple Metering, Vertical Gang
Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or
More informationSingle Socket and Horizontal Metering
G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are
More informationPower Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................
More informationService Entrance Methods
Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility
More informationPower Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................
More informationSECTION 500 METERING AND ASSOCIATED EQUIPMENT
SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.
More informationVolume 1 Residential and Light Commercial CA E December
Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application
More informationMeter Mains - Without Bypass
- 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat
More informationA. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.
SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationSelection and application guide. For use in Texas. Meter Mounting Equipment.
Selection and application guide For use in Texas Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and General
More informationSUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L
SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).
More informationPower Mod. Introduction.
Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination
More informationGeneral Specifications for Lighthouse Power Pedestal
Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4
More informationMetering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS
Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards
More informationCON EDISON EQUIPMENT
CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200
More information