1 ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

2 MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial, industrial, utility and transportation sectors. With 90 years of expertise in electrical engineering design and manufacturing, Milbank s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 97, Milbank is a family-owned, American manufacturer headquartered in Kansas City, Mo. For more information, please visit milbankworks.com. METERING As a market leader in electrical metering equipment, Milbank has set the standard for quality since 97. Hundreds of configurations are available, including many sizes, knockout configurations, terminal configurations, bypass options, hubs, locks and connectors. Milbank has the socket you need with thousands of active products to meet your utility s requirements. ENCLOSURES Milbank s line of enclosures include commercial junction boxes, panel mount enclosures, transformer cabinets, wireway, trough and industrial panel mount and push-button enclosures. Built with high-quality craftsmanship and materials which meet or exceed industry standards, Milbank enclosures are made to protect controls and equipment from dust, dirt and other harmful elements found in a wide variety of environments. ENCLOSED CONTROLS Milbank doesn t just build empty enclosures. We can deliver the entire package, complete with custom control equipment built to your exact specifications by our engineers. Milbank commercial pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Milbank s manual and automatic transfer switches are durable, easy to install and compatible with most generators. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

3 Table of Contents Air Conditioner Disconnects TABLE OF CONTENTS 0 & 60 amp AC disconnects amp AC disconnect with 0 amp GFCI receptacle... 6 Hot tub disconnects... 7 Single Position Sockets 00/00 amp, 4 terminal, ringless amp, 5 & 7 terminal, ringless amp, 4 terminal, ringless... 0 Meter Mains amp, 4 terminal, ringless amp, 4 terminal, ringless, with load center amp, 7 terminal, lever bypass, ringless amp, 4 terminal, lever bypass, ringless... 5 Multi-Position Sockets amp, 4 terminal, ringless amp, 7 terminal, ringless... 8 Multi-Position Meter Mains 5 & 00 amp, 4 terminals, ringless Knockout information... Transformer Rated 0 Amp, 6, 8, & Terminals... Pedestals 00 amp, 4 terminal,... 00/00 amp, 5 & 7 terminal, ringless, lever bypass amp, 4 terminal, ringless, meter main amp, 4 terminal, ringless, meter main w/ load center amp, 4 terminal, lever bypass, residential... 6 Miscellaneuous Circuit Breakers Accessories Commercial Pedestals Reference Information Index Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

4 4 4 CATALOG NUMBER LOGIC Catalog Number Logic How our product catalog numbers are derived Milbank drawing number TG: Triplex ground QG: Quadplex ground Lugs (Ø or Ø, 50 or 600 kcmil Single: K, K, K5, K7 Twin: K, K4, K6, K8 Utility specific designation U448-X-QG-5T9-K-BLG-ARE U: UL Listed S: Non-UL Listed UAP: UL, aluminum, painted AP: Non-UL Listed, aluminum, painted U: UL Listed S: Non-UL Listed UAP: UL, aluminum, Hub Openings & Closing Plates -O Blank top -RL Small hub opening -R Large hub opening -XL Small closing plate -X Large closing plate -RXL Large hub opening adapted to small closing plate -RRL Large hub opening adapted to small hub opening -PXL Closing plate packed inside 5th terminal designation 5T6: installed at 6:00 5T9: installed at 9:00 -WL hub -YL ¼ hub -ZL ½ hub -DL hub -EL ½ hub -F hub -G ½ hub -H 4 hub BLG: Barrel lock / guard provision painted KK: Horn bypass BL: Barrel lock U7040-RL-TG-KK-5T9-BL-AUT Milbank drawing number TG: Triplex ground QG: Quadplex ground 5th terminal designation 5T6: installed at 6:00 5T9: installed at 9:00 Utility specific designation Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

5 Air Conditioner Disconnects 0 & 60 Amps Fusible & Non-Fusible 5 AC DISCONNECTS U80 U8 U8 Milbank s air conditioner disconnect has a removable hinged cover for ease of installation. Our compact design meets NEC wiring space requirements and also complies with NEC article For safe working conditions, our disconnect pullers may be removed and reinstalled in the OFF position. Additionally, padlock provisions are included on the front cover. As with other Milbank products, our enclosure is constructed of G90U galvanized steel and electrostatically finished with an attractive, light gray, baked powder coating. Our epoxy/polyester resin blend offers a finish that is both durable and fade-resistant Amps Ø 40 VAC Air Conditioner Disconnects Catalog Number Amps Type Max H.P. Weight (lbs.) Line/Load Wire Range Ground Wire Dimensions Wire Rating Range CU/AL CU AL D" W" H" CU C AL C U80 60 Non-Fusible 0.5 #4-# #-# # /75 60 /75 U8 60 Non-Auto 0.5 #4-# #-# # /75 60 /75 U8 0 Fusible.5 #4-# #4-# # /75 60 /75 U86 60 Fusible 0. #4-# #4-# # /75 60 /75 UL listed as Enclosed Pullout Switch Type R rainproof One-inch concentric knockouts Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

6 6 AC DISCONNECTS Air Conditioner Disconnects 0 Amp GFCI Receptacle Specifications Meets NEC #0.6 requirements UL listed as Power Outlet Type R enclosure In-use cover* Duplex ground connector " concentric knockouts U8-0GWR Ø, 40 volt 60 amp, non-fused 0 amp GFCI receptacle Reset/test button Weather and tamper resistant Meets NEC #406.8 requirements 60 Amps Ø, 40 VAC Air Conditioner Disconnect with GFCI Receptacle Catalog Number Type Max H.P. Weight (lbs.) Line/Load Wire Range Ground Wire Range CU/AL Dimensions Wire Rating CU AL D" W" H" CU C AL C U8-0GWR Non-Fusible 0 6 #4-# #-# # /75 60 /75 Disconnect Pullers: To ensure the safest conditions, Milbank disconnect pullers are reversible so they may be reinstalled in the OFF position. Padlock Provision: All units are designed with a padlock provision on the cover for security. *In-Use Cover: Cover is rated as an in-use cover (cover may be closed with cords plugged into receptacle). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

7 Hot Tub Disconnects Type R Enclosures 7 HOT TUB DISCONNECTS U488-O-50GB U488-O-60GB Specifications 40 volt ground fault protection UL listed, Type R rainproof -pole, 50 or 60 amp GFCI breaker protection Compact size Three or four wire installation Ø, 0/40 VAC Standard package of Two extra one-pole breaker spaces 00 amp overall rating Easy to install 00 Amps Hot Tub Disconnect or Sub Panel Breaker Enclosure Type R Catalog Number Breaker Amps Type Weight (lbs.) Line/Load Wire Range Ground Wire Range CU/AL Dimensions CU AL D" W" H" U488-O-50GB 50 Breaker 8 #4-/0 #4-/0 #4-/ U488-O-60GB 60 Breaker 8 #4-/0 #4-/0 #4-/ Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

8 8 SINGLE POSITION SOCKETS Single Position Sockets 4 Terminal 00/00 Amp Ringless 600 VAC CECHA APPROVED 8949 U8949-RL-TG-KK-CECHA 00/00 Amp 4 Terminal Single Position Ringless Ø Catalog Number Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U8949-RL-TG-KK-CECHA OH H.O. #6-50 #6-50 Horn Hubs: Order hubs separately see accessory page for ordering information. Fifth Terminal: For field mounted fifth terminal, order catalog number K5T to fit into square opening at the 9 o clock position. Isolated Neutral: For indoor service, order as extra #BL048-KK complete interior block assembly to be installed to provide isolated neutral. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

9 Single Position Lever Bypass 00 Amp 5 & 7 Terminal Ringless 600 VAC 9 SINGLE POSITION LEVER BYPASS CECHA APPROVED U8606-RXL-CECHA 00 Amp Single Position Ringless Lever Bypass Catalog Number Terminals Service Hub Phase Connectors CU/AL Dimensions Knockouts Line Load D" W" H" 4 U864-RXL-CECHA 5 OH C.P. ØW #6-50 # , U8606-RXL-CECHA 7 OH C.P. Ø4W #6-50 # Hubs: Order hubs separately see accessory page for ordering information. Connectors: Units supplied with extuded aluminum connectors and bonded triplex neutral. Bypass: Lever supplied clamping action on meter spades and also operates bypass device. Isolated Neutral: For isolated neutral, order catalog number K047 (for the U8606 only). U864 can be field converted to isolated neutral by removing the bonding link. 4, Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

10 0 SINGLE POSITION LEVER BYPASS Single Position Lever Bypass 0 Amp 4 Terminal Ringless 600 VAC CECHA APPROVED 46 U46-X-QG-CECHA 0 Amp Continuous (400 Amp Max) 4 Terminal Single Position Ringless Ø Catalog Number Service Hub U46-X-QG-CECHA OH H.O. Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 8" x 6 Studs 8" x 6 Studs Lever , 4 Fifth Terminal: For field-installed fifth terminal, order catalog number K865. Connectors: Supplied with /8 X 6 hex head nuts with Belleville washers. For connector kits, see accessories page. This unit is UL listed based on parallel 50 conductors max only. Bypass: Lever supplies clamping action and also operates bypass device. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

11 Meter Mains Amp 4 Terminal Ringless 40 VAC METER MAINS CECHA APPROVED Catalog Number U775-RL-KK Service Hub Amp 4 Terminal Meter Mains (Plug-In) Ringless Ø U7607-RL-00-KK supplied with 00 amp circuit breaker Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U775-RL-KK OH H.O. #6-/0 C.B. Horn Circuit Breaker: Main circuit breaker not supplied with unit. For 00 amp service, order catalog number Q00 separately. See circuit breaker chart on accessory page for other compatible models. Fifth Terminal: For field-installed fifth terminal, order catalog number 5T8K. Hubs: Order hubs separately see accessory page for ordering information. 4, 00 Amp 4 Terminal Meter Mains Ringless Ø Catalog Number Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U7607-RL-00-KK-CECHA OH H.O. #6-50 #-00 Horn , Circuit Breaker: 00 amp main circuit breaker factory bussed. Order catalog number UQFB-00-X for replacement. Other amperages available see circuit breaker chart on accessory page. Fifth Terminal: For field-installed fifth terminal, order catalog number K5T. Hubs: Order hubs separately see accessory page for ordering information. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

12 METER MAINS Meter Mains Amp 4 Terminal Ringless 40 VAC CECHA APPROVED U584-RL-00-KK-CECHA Amp 4 Terminal Meter Mains Ringless Horn Bypass Catalog Number Service Hub Connectors CU/AL Dimensions Knockouts Line Load D" W" H" U584-RL-KK-CECHA OH H.O. # U584-RL-00-KK-CECHA OH H.O. #6-50 CB - 00A U584-RL-5-KK-CECHA OH H.O. #6-50 CB - 5A U584-RL-00-KK-CECHA OH H.O. #6-50 CB - 00A , 4, 4, 4, AIC Rating: All models are rated K AIC when using Siemens QPH (00A) or QNH (00A) breakers. Fifth Terminal: For field installable fifth terminal kit, order K5T. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

13 Meter Main With Load Center Amp 4 Terminal Ringless 40 VAC METER MAIN W/ LOAD CENTER CECHA APPROVED U568-XTL-00-KK-CECHA 4 Terminal Meter Mains ØW Ringless OH Catalog Number Amps Circuits Hub Connectors CU/AL - Line Dimensions Knockouts D" W" H" U568-XTL-00-KK-CECHA 00 8 C.P. # , 4 U568-XTL-50-KK-CECHA 50 8 C.P. # , 4 U568-XTL-00-KK-CECHA 00 8 C.P. # , 4 4, 4, 4, Hubs: Supplied with two closing plates packed inside. Order hubs as a separate item. For proper hub selection, refer to the hub suffix chart on the accessories page. Fifth Terminal: For field installed fifth terminal, order K5T. Breakers: Rated K AIC with Milbank QNR00H main installed. Main Breaker: U568 and U569 also available with amp breakers, consult factory. Sub Feed Lugs: #6-50 sub feed lugs provided on 8 circuit interior. Not available on 0 circuit interior. Generator Interlock K585 Large QN with small frame Q K580 Large frame QN with large frame QN K580 Small frame Q to small frame Q AIC Rating Amps Siemens Cutler Hammer General Electric Sqaure D 0k QNR BR (50A only) 5 QP HQP, BR THQL, THQL-GF Homeline k QNRH 8 5 QPH Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

14 4 METER MAINS Meter Mains 00 Amp 7 Terminal Lever Bypass Ringless CECHA APPROVED U5750-RXL-00-BL-CECHA 00 Amp Meter Mains Ringless Ø4W 40V Lever Bypass OH Catalog Number Terminals Hub Connectors CU/AL - Line Dimensions Knockouts D" W" H" 4 U5750-RXL-00-BL-CECHA 7 C.P. # Bypass: Lever supplies clamping action on meter spades and also operates bypass device. Breakers: Factory installed 00 amp, -pole, 0K AIC. Side Wireway: Allows for underground service. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

15 Lever Bypass Meter Mains 0 Amp 4 Terminal Ringless 5 METER MAIN W/ LEVER BYPASS U5890-X-/00 CECHA APPROVED U5894-X-/ Amp 4 Terminal Meter Mains Lever Bypass Ringless Connectors CU/ Catalog Number Service Hub AL Branch Dimensions Knockouts Circuits Line D" W" H" 4 5 U5890-X-/00 OH C.P. 8" x 6 Studs N/A U5894-X-/00 OH C.P. 8" x 6 Studs , 4 U5895-X-/00 OH C.P. 8" x 6 Studs , 4 Breakers: All units come with two 00A main breakers. Side Bussed Units: U5894 and U5895. Main Lug Kit: U5894 shown with K70 main lug kit installed, but sold separately. Fifth Terminal: For field mounted fifth terminal order catalog number K Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

16 6 MULTI-POSITION SOCKETS Multi-Position Sockets 00 Amp 4 Terminal Ringless 00 VAC CECHA APPROVED L57 L57-XL-KK-CECHA L57 L574 L575 L Amp per Position 4 Terminal Multi-Position Ringless ØW Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" L57-XL-KK-CECHA OH C.P. #6-50 #6-/0 Horn , L57-XL-KK-CECHA OH C.P. #6-50 #6-/0 Horn , L574-XL-KK-CECHA 4 OH C.P. #6-50 #6-/0 Horn , L575-XL-KK-CECHA 5 OH C.P. #6-50 #6-/0 Horn , L576-XL-KK-CECHA 6 OH C.P. #6-50 #6-/0 Horn , Hub: For proper hub selection refer to the hub suffix chart on the accessory page. Fifth Terminal: For field-installed fifth terminal, order 5T8K (6 o clock position) or K9959 (9 o clock position). Connectors: Extruded aluminum connectors are tin plated. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

17 Multi-Position Sockets 00 Amp 4 Terminal Ringless 00 VAC 7 MULTI-POSITION SOCKETS CECHA APPROVED 5 PED U5-X-KK-K-PED (shown without pedestal) PED 5 PED 54 PED PED 00 Amp per Position 4 Terminal Multi-Position Ringless Catalog Number Positions Service Hub Connectors CU/AL Dimensions Knockouts Line Load D" W" H" U5-X-KK-K-PED OH/UG* C.P. #6-50 # U5-X-KK-K-PED OH/UG* C.P. #4-600 # U54-X-KK-K-PED 4 OH/UG* C.P. #4-600 # U55-X-KK-K4-PED 5 OH/UG* C.P. () #-600 # U56-X-KK-PED 6 OH/UG* C.P. 8" x 6 Studs # Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page. For the U54-6 two hub openings are supplied and the extra opening is closed with a closing plate as standard. Fifth Terminal: For field mounted fifth terminal, order catalog number K5T (9 o clock position). Bussing: Bussing is 5 6" x " aluminum on U5 & U5 and 8" x " aluminum on U Refer to the conduit & ampacity page for information on ampacity of bussing. *Underground Applications: For underground service, order S9-TO pedestal raceway. A " pedestal extension kit is also available order catalog number S57. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

18 8 LEVER BYPASS MULTI-POSITION Lever Bypass Multi-Position Sockets 00 Amp 7 Terminal Ringless 00 VAC CECHA APPROVED U7-XT-PED (shown without pedestal) PED 7 PED 7 74 PED PED 00 Amp 7 Terminal Multi-Position Lever Bypass Ringless Catalog Number Positions Service Hub PED Connectors CU/AL Dimensions Knockouts Line Load D" W" H" U7-XT-PED OH/UG () C.P. 8" x 6 Stud # U7-XT-PED OH/UG () C.P. 8" x 6 Stud # U74-XT-PED 4 OH/UG () C.P. 8" x 6 Stud # U75-XT-PED 5 OH/UG () C.P. 8" x 6 Stud # U76-XT-PED 6 OH/UG () C.P. 8" x 6 Stud # , 4, 4, 4, 4, Hubs: Units supplied with two closing plates. To order hubs as extra, refer to the hub suffix chart on the accessories page. Connector Kits: For line side connector kits, order as extra K08 (50 kcmil), K44 (600 kcmil), twin K44 (50 kcmil), twin K08 (600 kcmil). Line connectors can be reversed to change from OH to UG service. Bypass: Lever supplies clamping action on meter spades and also operates bypass device. Underground Applications: For underground service, order S9-TO raceway. A " pedestal extension kit is also available order catalog number S57. Bussing: Bussing is 8" x " aluminum. Refer to the conduit & ampacity page for information on ampacity of bussing. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

19 Multi-Position Meter Mains 5 & 00 Amp/Position 4 Terminal Ringless 0/40 VAC 9 MULTI-POSITION METER MAINS CECHA APPROVED U854-X-KK-PED U866-X-KK-PED (Order circuit breakers as extra; (Order circuit breakers as extra; shown without pedestal) shown without pedestal) 5 Amp Per Position Multi-Position Sockets Ringless 00 Amp Per Position Multi-Position Sockets Ringless Connector Kits* Size Single Twin Catalog Number Positions Main Bus Rating Short Circuit Current Rating Breaker Chart Line Connector Size Dimensions D" W" H" U85-X-KK-K-PED-CECHA 00 Amp 0K AIC # U85-X-KK-K-PED-CECHA 00 Amp 0K AIC # U854-X-KK-PED-CECHA Amp 0K AIC # U855-X-KK-PED-CECHA Amp 0K AIC 8" x 6 Stud* U856-X-KK-PED-CECHA Amp 0K AIC 8" x 6 Stud* Catalog Number Suffix Kit Number Positions Compatible With Main Bus Rating Wire Range -K K59 U85-56, U86-66 #6-50 -K K540 U854-56, U # K K50 U854-56, U86-66 #6-50 -K4 K54 U #-600 Short Circuit Current Rating Manufacturer Line Connector Size 5-00 Amps Dimensions D" W" H" U86-X-KK-K-PED-CECHA 50 Amp 0K AIC # U86-X-KK-K-PED-CECHA 00 Amp 0K AIC # U864-X-KK-PED-CECHA Amp 0K AIC 8" x 6 Stud* U865-X-KK-PED-CECHA Amp 0K AIC 8" x 6 Stud* U866-X-KK-PED-CECHA Amp 0K AIC 8" x 6 Stud* Amps or Less Cutler Hammer BR, WBJ QP, BR Siemens QNR QP G.E. THQ THQ Square D Homeline *Connectors: For line wire connector kits, order separately. Fifth Terminal: For field mounted fifth terminal, order catalog number K8. Order one per meter position. Breakers: Units have provision for one double pole main per meter position. Breakers not included. Underground Applications: For underground service, order S9-TO raceway. Order separately. Racway Extension Kit: A " extension kit is also available. Order catalog number S57. Knockouts: See next page for drawings and knockout configurations. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

20 0 MULTI-POSITION METER MAINS Multi-Position Meter Mains Knockout Information Catalog Number Knockouts U85-X-KK 4 U85-X-KK 4 U854-X-KK 4 4, 4, 4, U855-X-KK 4 4, U856-X-KK 4 4, U86-X-KK 4, U86-X-KK 4, U864-X-KK 4, U865-X-KK 4, U866-X-KK 4, Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

21 Transformer Rated 0 Amp 6, 8 & Terminals TRANSFORMER RATED CECHA APPROVED CE6 6 8 CE 0 Amp Transformer Rated Sockets Ringless Catalog Number Terminals Phase Service Hub Dimensions Knockouts D" W" H" CE6-CECHA 6 ØW UG Blank CE8-CECHA 8 ØW UG Blank CE-CECHA Ø4W UG Blank , 4, 4, Type R enclosure. One-piece sealable cover with padlock provision. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

22 RESIDENTIAL PEDESTAL Residential Pedestal 00 Amp 4 Terminal Single or Double Position CECHA APPROVED 4 4 GRADE LINE U846-O Extension Unit K5800 U80-O Extension Unit S Amp 4 Terminal Ringless ØW Residential Pedestal Catalog Number Amps Service Hub Bypass U846-O-CECHA 00 UG Blank Horn U80-O-CECHA 00 UG Blank Horn Connectors CU/AL Dimensions Knockouts Line (Compression) 4/0 (Line) /0 (Neutral) 4/0 (Line) /0 (Neutral) Load D" W" H" 4 # , # Hanging Hook: Supplied with keyhole hanger for easy mounting. Extension Unit: For U846, order extension unit K5800 for 5 burial applications and two K5800 units for 0 burial applications. For U80, order extension kit S8988 for 4 burial applications. Fifth Terminal: For field installed fifth terminal, order catalog number K5T. 4, 5 6 Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

23 Lever Bypass Meter Pedestals 00/00 Amp 5 & 7 Terminal Ringless 600 VAC LEVER BYPASS METER PEDESTALS CECHA APPROVED U907-O -CECHA 00/00 Amp Metered Pedestals Lever Bypass Ringless Lever Bypass Catalog Number Terminals Phase Service Hub Connectors CU/AL Dimensions Knockouts Line Load D" W" H" U908-O-CECHA 5 ØW or ØW UG Blank /0-4/0 # U907-O-CECHA 7 Ø4W UG Blank /0-4/0 # Bypass: Lever supplies clamping action on meter spades and also operates bypass device. Neutral Disconnect: The U908 has a manual neutral disconnect bolt. Direct Burial: For free standing use, order separately burial kit #S488. Fifth Terminal: U908 Includes factory installed fifth terminal at 9 o clock. For fifth terminal at 6 o clock, substitute -5T6 suffix in catalog number. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

24 4 METER MAIN PEDESTAL Meter Main Pedestal Amp 4 Terminal Ringless CECHA APPROVED Grade Line 8980 NU8980-O-00-KK Amp 4 Terminal Ringless Underground Service Catalog Number Hub Connectors CU/AL Main Breaker Dimensions Knockouts Bypass Line Load 0K K D" W" H" NU8980-O-KK Blank #6-50 CB* Horn NU8980-O-KK-LP Blank #6-50 CB* Horn NU8980-O-SF00-KK Blank #6-50 #6-/0 Horn Q00 Q00H NU8980-O-SF00-KK-LP Blank #6-50 #6-/0 Horn Q00 Q00H NU8980-O-00-KK Blank #6-50 /0-00 Horn UQFP UQFPH NU8980-O-00-KK-LP Blank #6-50 /0-00 Horn UQFP UQFPH * Field Installed Circuit Breaker Required. Series Wired Main: For series wired main order wire kit K474 and UQFPH-M type circuit breaker. Branch Circuit Breakers: Branch interior accepts most manufacturers small frame plug-in type circuit breakers (Milbank, GE, Siemens, Cutler-Hammer). SF: SF in catalog number has small frame plug-in type circuit breaker installed on middle stabs of 4-circuit interior. Only two single pole space available. Fifth Terminal: For field-installed 5th terminal order kit K5T. Mounts in 9 o clock position only. Extension Kit: Available for low profile (-LP) units only. Order kit K4694. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

25 Meter Main w/ Load Center Pedestal 00 Amp 4 Terminal Ringless 5 METER MAIN W/ LOAD CENTER PEDESTAL CECHA APPROVED U5706-O-00S-KK-CECHA Pedestal shown with receptacles installed. Receptacles are sold separately. Consult factory to order with receptacles installed. 00 Amp 4 Terminal Meter Main Pedestal Ringless Catalog Number Service Bypass Connectors CU/AL Dimensions Knockouts Line Load D" W" H" 4 U5706-O-00S-KK-CECHA UG Horn #6-50 CB , Fifth Terminal: For field installed fifth terminal, order part number K5T. Branch Circuit Breakers: Branch interior accepts most manufacturers small frame plug-in type circuit breakers (GE, Siemens, Cutler Hammer, Murray). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

26 6 LEVER BYPASS RESIDENTIAL PEDESTAL Lever Bypass Residential Pedestal 0 Amp Continuous 400 Amp Max 4 Terminal Grade Line Grade Line Grade Line Grade Line 8 8" " O.D /" I.D. 849 U748-O 6-5/6" 5" CECHA APPROVED U849-O-/ Amp 4 Terminal Without Breaker Ringless Catalog Number Service Hub Bypass Connectors CU/AL Dimensions Knockouts Line Load D" W" H" U748-O UG Blank Lever 8" x 6 Studs Twin # Bypass: The lever supplies clamping action on the meter spade and also operates the bypass device. Fifth Terminal: For field-installed fifth terminal order kit K865. Pedestal Extension Kit: If extension kit is required, order as extra kit S Amp 4 Terminal Meter Main with Breakers Ringless Connectors CU/AL Dimensions Knockouts Catalog Number Service Hub Bypass Line Load D" W" H" U849-O-/00 CECHA UG Blank Lever 8" x 6 Studs CB #-00 kcmil U849-O CECHA UG Blank Lever 8" x 6 Studs See lug note below* Breakers: The U849 is furnished with () Milbank type UQFBH K AIC circuit breakers. Pedestal Extension Unit: If extension kit is required, order as extra kit # S848. Bypass: The lever supplies clamping action on the meter spade and also operates the bypass device. Fifth Terminal: For field-installed fifth terminal order kit K865. *Lugs: The 00A is /0-00 and the 00A is #-#. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

27 Joint Use Termination Cabinet Accommodates telephone and cable conductors 7 JOINT USE TERMINATION CABINET 6" " 58" 7 5/6" 5/6" 9" CECHA APPROVED Grade Line " 49 " 4 /" U49-O Joint Use Termination Cabinet Catalog Number Hub Bypass Connectors CU/AL Dimensions Knockouts Line Load D" W" H" U49-O Blank None None None Communication Compartment: Easily attaches to Milbank meter pedestals for use in new construction. Telephone and Cable Conductors: This unit will accommodate both telephone and cable conductors, eliminating the use of multiple, unsightly network interface devices on the outer structure of the home, while providing tamper resistance to the communication modules. Single Location Point of Service: The U49 combined with the Milbank meter pedestal provides a single location point of service, making access for utility service personnel convenient and efficient. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

28 8 CIRCUIT BREAKERS Circuit Breakers UQFP Plug-In & UQFB Bolt-On Series 0/40 VAC UQFP UQFPH UQFP-M UQFPH-M UQFB-X UQFBH 00 Amp Frame Plug-In 0,000 AIC &,000 AIC Two-Pole Common Trip Amps 0K AIC Plug-In K AIC Plug-In 0K AIC Plug-In K AIC Plug-In Wire Range 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 #-# #-/0 5 UQFP-5 UQFPH-5 UQFP-M-5 UQFPH-M-5 #-# #-/0 50 UQFP-50 UQFPH-50 UQFP-M-50 UQFPH-M-50 /0-00 / UQFP-75 UQFPH-75 UQFP-M-75 UQFPH-M-75 /0-00 / UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 /0-00 / Amp Frame Bolt-On 0,000 AIC &,000 AIC Two-Pole Common Trip Amps 0K AIC Bolt-On K AIC Bolt-On 0K AIC Bolt-On K AIC Bolt-On CU Wire Range 00 UQFB-00 UQFBH-00 UQFB-00-X UQFBH-M-00 #-# #-/0 5 UQFB-5 UQFBH-5 UQFB-5-X UQFBH-M-5 #-# #-/0 50 UQFB-50 UQFBH-50 UQFB-50-X UQFBH-M-50 /0-00 / UQFB-75 UQFBH-75 UQFB-75-X UQFBH-M-75 /0-00 / UQFB-00 UQFBH-00 UQFB-00-X UQFBH-M-00 /0-00 /0-00 UL Listed: For use with 60 C or 75 C wire. UQFP: For parallel main circuit breaker applications. UQFP-M: For series main circuit breaker applications Split load tab features allow for feed-through capability. UQFB: () /0-00 lugs provided on load and line side (cable-in, cable-out). UQFB: Three-pole available. Consult factory. UQFB-X: () /0-00 lugs provided on load side and () line bar bus connections on line side. UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed-through capability. CU AL AL Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

29 Circuit Breakers QP (small frame) and QN (large frame) 0/40 VAC 9 CIRCUIT BREAKERS 5 5 Amp Breaker Plug-In Type Per Pole Amps Poles 0K AIC Plug-In K AIC Plug-In 5 Single Q5 Q5H 5 Double Q5 Q5H 0 Single Q0 Q0H 0 Double Q0 Q0H 5 Single Q5 Q5H 5 Double Q5 Q5H 0 Single Q0 Q0H 0 Double Q0 Q0H 5 Single Q5 Q5H 5 Double Q5 Q5H 40 Single Q40 Q40H 40 Double Q40 Q40H 50 Single Q50 Q50H 50 Double Q50 Q50H 60 Single Q60 Q60H 60 Double Q60 Q60H 70 Single Q70 Q70H 70 Double Q70 Q70H 80 Double Q80 Q80H 90 Double Q90 Q90H 00 Double Q00 Q00H 5 Double Q5 Q5H QN00H WBJ00 QN00RH Q50 00 Amp Frame Plug-In 0,000 AIC &,000 AIC Two-Pole, Common Trip Amps 0K AIC Plug-In K AIC Plug-In Handle Location Wire Range CU AL 50 QN50 QN50H Left facing #4-00 # QN00 QN00H Left facing #4-00 # QN50R QN50RH Right facing #4-00 # QN00R QN00RH Right facing #4-00 # WBJ50 Centered #-00 # WBJ00 Centered #-00 #-00 Load connectors supplied with breakers. UL Listed for use with 60 C or 75 C wire. Wire sizes shown are lug capacity. Consult NEC Article #0 for specific wire sizes. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

30 0 ACCESSORIES Accessories Hubs and Closing Plates -RL Small hub opening -WL A754 -YL A755 -ZL A756 -DL A757 -EL A758 -XL A755 " hub 4" hub " hub " hub " hub Small closing plate -R Large hub opening -F A80 -G A8 -H A8 -X A9064 -RRL S84 -RXL S84 A755 " hub " hub 4" hub Large closing plate Large hub opening adapted to small hub opening Suffix: Add to catalog number for factory installation of hub. Packaging: Individually packed units for field installation. Abbreviations: H.O. (hub opening), C.P. (closing plate). Hub Mast rated Large Hub opening adapted to small closing plate Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

31 Accessories Connector Kits, Closing Kits & Generator Interlock ACCESSORIES Connector Kits For Use with 8"-6 Stud Type Units Only Bypass Link Single Twin Suffix Part # ( per set) - Ø Suffix Part # ( per set) - Ø K K K K K K or () /0-50* KL K50L 6-50 (non rotating) KL K540L or () /0-50* (non rotating) K4 K Suffix Part # (4 per set) - Ø Suffix Part # (4 per set) - Ø K5 K K6 K K7 K or () /0-50* K8 K K880 (sold in pairs) Note Consult factory for proper connector kits for studded meter sockets. *For () /0-50, conductors must be of same size. Closing Covers Disconnect Sleeve Isolated Neutral Kit Meter Closing Plate (Ring Type / Ringless) Metal Closing Plate (For Ringless Sockets) Grey Plastic CP Clear Plastic Clear Plastic M5-44 Do not use with lever bypass sockets K047 * Isolated neutrals are specific to the meter socket. Consult factory for correct isolated neutral. Pole Hanger Kit 850 comes with 4 pole hangers ANSI-6-Grey A-GP oz. spray can of grey paint Catalog Number 850 Description of pole hanger brackets Two pair (4 pieces) with mounting hardware Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

32 ACCESSORIES Accessories Fifth Terminals, Tap Connectors & Block Assemblies Fifth Terminals 5T8K Amp Plug-In K5T - 00 Amp (Block with Square Hole) K865 - Heavy Duty Jaw Clamping (K866 without Neutral Wire) K56 Tap Connectors ( per set) Replaces the load or line side slide-in nut assembly on Milbank 00 amp sockets. Allows for a 00 amp tap location in addition to the #6-50 kcmil load-side connector. K50 includes safety barrier extensions for applications over 00 VAC. Three lugs per kit. K4977-INT - Internal Hex K4977-EXT - External Hex K50-INT - Internal Hex (set of 4 w/ barrier) Wire Range # - /0 Triplex Ground K90 (For factory installed triplex ground, add suffix -TG to catalog number) 00 Amp Blocks (single sockets only) 00 Amp Blocks (single sockets only) BL Block Assembly Z AO - Slotted Nut Assembly Z80965-AC - Neutral without Nut Z9095-AC - Hex Nut Set Screw K457 - Internal Hex Block Assembly (w/ meter support) K458 - External Hex Block Assembly (w/ meter support) Z9665-AO - Internal Hex Slide Nut Assembly Z9664-AO - External Hex Slide Nut Assembly Z84898-AC - Neutral without Nut Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

33 Commercial Pedestals Attractive Easy to Install Secure Cost-Effective COMMERCIAL PEDESTALS Milbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly, costly and inefficient strut and backboard structures. Strut and backboard Commercial pedestal UL-listed as Industrial Control Equipment (File E855) Standard Features Type R rainproof, vandal-resistant cabinet of polyurethane powder-coated steel (aluminum or stainless steel also available) UL-listed as enclosed industrial control equipment (UL508) Isolated lockable and sealable utility metering and lug landing sections Lockable customer section for distribution and control equipment with internal deadfront Print pocket inside customer section door contains wiring schematics and installation instructions Most load centers are UL-listed for use with various manufacturers circuit breakers All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws) Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

34 4 COMMERCIAL PEDESTALS Commercial Pedestals Attractive Easy to Install Secure Cost-Effective These units are ideal for controlling and metering: Traffic signals Street lighting Irrigation and sprinkler systems Cell towers and telephone vaults Pump stations Temporary power for fairgrounds, swap meets, outdoor markets, portable offices, holiday lights, etc. Outdoor lighting for athletic fields, tennis and basketball courts, parking lots, landscaping and subdivision entrances, etc. Available Factory-Installed Options Meter sockets: ring type or ringless, up to 400 amp Main and branch breakers or T fuses Distribution: copper load centers and panel boards Clocks, timers and relays Photoelectric cells and controls Power receptacles: pin and sleeve, twist lock or straight blade Contactors: definite purpose, electrical or mechanically held, IEC and mercury types Surge protection and lightning arrestors Reserve inlet generator receptacle with interlocked circuit breakers Motor starters and relays Push button controls Thermostat controls, fans and heating strips Power blocks and terminal blocks Steel, aluminum and plywood backboards Transformers Interlock devices for circuit breakers Available in steel, aluminum (unpainted, painted or anodized) or stainless steel construction with powder-coated finish available in eight standard colors or special-ordered RAL colors Available for applications up to 400 amp, 0V, 08V, 40V, 77V, 480V - Ø or Ø Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

35 Watthour Meter Forms Standard Forms Transformer Rated or Self-Contained 5 WATTHOUR METER FORMS SC SC TR TR TR and -WIRE FORMS S & S and -WIRE FORMS S & S with BYPASS -WIRE FORM S 5th Term. 9 o'clock -WIRE FORM S with BYPASS -WIRE FORM S 5th Term.6 o'clock TR SC SC SC SC -WIRE FORM S with BYPASS ELEMENT -WIRE NETWORK FORM S 5th TERM. 9 o'clock ELEMENT -WIRE NETWORK FORM S with BYPASS 5th Term. 9 o'clock ELEMENT -WIRE NETWORK FORM S 5th TERM. 6 o'clock ELEMENT -WIRE NETWORK FORM S with BYPASS 5th Term. 6 o'clock TR TR SC SC TR -WIRE FORM 4S -WIRE FORM 4S WITH BYPASS or ELEMENT 4W Y or Y FORM 4S FORM 5S Y FORM 6S or ELEMENT 4W Y or FORMS 4S & 5S with BYPASS ELEMENT 4W Y or Y FORM 7S FORM 4S with BYPASS TR TR SC SC TR ELEMENT W, 4W, W FORM 5S ELEMENT W, 4W, W FORM 5S with BYPASS ELEMENT W, 4W, W FORM S or ELEMENT W, 4W, W FORM S with BYPASS or ELEMENT 4W Y or Y FORM 9S FORM 8S TR = TRANSFORMER RATED SC = SELF CONTAINED TR TR TR or ELEMENT 4W Y or FORMS 8S & 9S with BYPASS ELEMENT 4W Y FORM 6S ELEMENT 4W Y FORM 6S with BYPASS Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

36 6 METER FORMS Meter Forms Reference Information DIAGRAM A W with P.T. & C.T. Single Stator Meter(W ) - Form S 5T Socket, Test Switch #TS04-00 DIAGRAM B W with C.T. Single Stator Meter (W ) - Form S 5T Socket, Test Switch #TS04-00 DIAGRAM C W with C.T. s Single Stator Meter (W ) - Form 4S 6T Socket, Test Switch #TS DIAGRAM D W or W Network with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM A DIAGRAM B DIAGRAM C DIAGRAM D (ALT.LOC.) (ALT.LOC.) P PN C C P PN C C P P C C C C P P C PN C C C P.T. I LINE N (BONDED) C.T. LOAD I LINE N (BONDED) C.T. LOAD I LINE N (BONDED) C.T. C.T. LOAD I LINE N (BONDED) C.T. C.T. LOAD DIAGRAM E W with P.T. s & C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM F W with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM G 4W Y with C.T. s Stator Meter - Form 6S T Socket, Test Switch #TS0-009 DIAGRAM H 4W Y with P.T. s & C.T. s Stator Meter - Form 6S T Socket, Test Switch #TS0-009 DIAGRAM E DIAGRAM F DIAGRAM G DIAGRAM H P P PN C C C C C C P P PN C C C C C C P P P C C C C P C P P C C C LINE PT PT C.T. C.T. LOAD LINE C.T. C.T. LOAD LINE N (BONDED) C.T. LOAD C.T. C.T. PT PT LINE N (BONDED) C.T. LOAD C.T. C.T. DIAGRAM I 4W Y or with C.T. s Y Stator Meter - Form 9S Stator Meter - Form 8S T Socket, Test Switch #TS0-009 P P P PN C DIAGRAM I C C C C C DIAGRAM J 4W Y with P.T. s & C.T. s Stator Meter - Form 9S T Socket, Test Switch #TS0-009 P DIAGRAM J P PN C P C C C C C Prewiring: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. LINE N (BONDED) C.T. LOAD C.T. C.T. PT PT PT LINE N (BONDED) C.T. LOAD C.T. C.T. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

37 Conduit, Ampacity & SCCR Reference Information 7 CONDUIT, AMPACITY & SCCR MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT Table from 008 NEC Code Reference: Rigid Metal Conduit Type THHN, THWN, THWN- XHH, XHHW, XHHW- Conductor Size (AWG/kcmil) Conduit Trade Sizes (Inches) / / / / / / / This table is for concentric stranded conductors only. For cables with compact conductors refer to NEC. Refer to latest NEC Code or Local Codes for updated requirements. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

38 8 ENERGIZATION OF ELECTRICAL EQUIPMENT Energization of Electrical Equipment Important Information for Installers Important Note In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. Before Energizing. Give equipment a thorough visual examination to determine that: A. No shipping or installation damage exists. B. Proper clearances have been maintained. C. All connections have been made. D. Equipment is clean and dry.. Make a thorough examination to: A. Verify tightness of all bolted connections (see table below). B. Manually operate all circuit breakers, switches, relays, etc. C. Check rigidity of all mountings, bus bars and components. D. Use test equipment to check continuity of circuitry and integrity of insulation.. All switches and circuit breakers should be in the off position. 4. Verify that manual meter bypass (if applicable) is in non-bypass position. 5. Install cover and/or close doors. 6. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization. When Energizing Use caution and follow established safety procedures: ) Wear safety apparel. ) Use safety equipment. ) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. After Energizing Secure the installation: ) To prevent accidental contact with energized parts, cover all openings with approved filler devices. ) To prevent unauthorized access, secure all covers and/or doors with approved security devices. ) Attach/post information to advise others of potential hazards associated with the installation. Recommended Torque for General Applications* Nominal Joint Description Torque Head Type Size Screw Nut (Inch Lbs.) 0 Brass Brass Nut or Extruded Hole All 0-5 inch lbs. 0 Steel Copper or Aluminum Busbar /8" All 5-0 inch lbs. 0 Steel Steel Nut or Extruded Hole; CU or AL Busbar > /8" All 0-5 inch lbs. Steel Aluminum Extruded Hole All 0-5 inch lbs. Steel Steel Nut or Extruded Hole All inch lbs. /4 Steel Aluminum Extruded Hole All inch lbs. /4 Steel Steel Nut or Extruded Hole; CU or AL Busbar All inch lbs. 5/6 Steel Aluminum Extruded Hole Hex inch lbs. 5/6 Steel Steel Nut or Extruded Hole; CU or AL Busbar Hex inch lbs. /8 Steel Steel Nut Hex inch lbs. / Steel Steel Nut Hex inch lbs. * Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. CU: Copper AL: Aluminum Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

39 Materials & Finishes Reference Information 9 MATERIALS & FINISHES Materials Steel Quality The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. Steel Sheet 6 gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. (AISI G90) 4 gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. Aluminum Extrusion Wire-Terminals: Alloy; 606-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 60-O & 606-O Aluminum Sheet 000 series aluminum sheet, H4, or 505 series aluminum sheet, H. Where applicable thicknesses range from Copper Sheet & Bus Electrolytic copper with tin plating in most applications. Insulating Materials In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. Finish Process Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. Metal Fastners Zinc-coated with a chromate dip. Ratings & Compliance Ratings & Compliance All Milbank electrical enclosures in this catalog are rated Type R Enclosure unless specified otherwise on the product s page. All enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code. UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 44, File E00), Test Switches (UL 44, File E65), Power Outlets (UL, File E90945), Panelboards (UL 67, File E68) and Pullout Switches (UL 49, File E06). Additional standards are utilized as applicable: Meter Sockets (ANSI C.7), Test Switches (ANSI C.9) and Panelboards (NEMA PB-). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

40 40 INDEX J...9 5T8K...6 A A A A A A A A8...5 A8...5 A CE... CE6... CE8... CP-6PDMNT-CALT...9 CP-4PDMNT-CALT...9 CP-ABK5/8...9 CP-PE-HOA-POS...9 CP-TC4H...9 CP-TC7D...9 CP-TCWIRE...9 K K K K50L...6 K K K540L...6 K K8...7 K K K K K K K K K K4977-EXT...7 K4977-INT...7 K50-INT...7 K K K K K5T...7 K L57-XL-KK...6 L57-XL-KK...6 L574-XL-KK...6 L575-XL-KK...6 L576-XL-KK...6 M NU8980-O-00-KK...4 NU8980-O-00-KK-LP...4 NU8980-O-KK...4 NU8980-O-KK-LP...4 NU8980-O-SF00-KK...4 NU8980-O-SF00-KK-LP...4 Q5...4 Q5H...4 Q0...4 Q0H...4 Q5...4 Q5H...4 Q0...4 Q0H...4 Q5...4 Q5H...4 Q Q40H...4 Q Q50H...4 Q Q60H...4 Q Q70H...4 Q Q00H...4 Q5...4 Q5H...4 Q5...4 Q5H...4 Q0...4 Q0H...4 Q5...4 Q5H...4 Q0...4 Q0H...4 Q5...4 Q5H...4 Q Q40H...4 Q Q50H...4 Q Q60H...4 Q Q70H...4 Q Q80H...4 Q Q90H...4 QN QN50H...4 QN50R...4 QN50RH...4 QN QN00H...4 QN00R...4 QN00RH...4 S S S S S U5-X-KK-K-PED...7 U5-X-KK-K-PED...7 U54-X-KK-K-PED...7 U55-X-KK-K4-PED...7 U56-X-KK-PED...7 U748-O...6 U85-X-KK-K-PED...9 U85-X-KK-K-PED...9 U854-X-KK-K-PED...9 U855-X-KK-PED...9 U856-X-KK-PED...9 U86-X-KK-K-PED...9 U86-X-KK-K-PED...9 U864-X-KK-PED...9 U865-X-KK-PED...9 U866-X-KK-PED...9 U7-XT-PED...8 U7-XT-PED...8 U74-XT-PED...8 U75-XT-PED...8 U76-XT-PED...8 Index Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

41 Index 4 INDEX U U8...5 U8-0GWR...6 U8...5 U849-O-/ U U49-O...7 U46-X-QG-CECHA...0 U488-O...7 U488-O-50GB...7 U488-O-60GB...7 U568-XTL-00-KK-CECHA... U568-XTL-50-KK-CECHA... U568-XTL-00-KK-CECHA... U5706-O-00S-CECHA...5 U5750-RXL-00-BL-CECHA...4 U584-RL-00-KK-CECHA... U584-RL-5-KK-CECHA... U584-RL-00-KK-CECHA... U584-RL-KK-CECHA... U5890-X-/ U5894-X-/ U5895-X-/ U775-RL-KK... U7607-RL-00-KK... U80-O... U846-O... U8606-RXL...9 U864-RXL...9 U8949-RL-TG-KK...8 U907-O... U908-O... UQFB UQFB-00-X... UQFB-5... UQFB-5-X... UQFB UQFB-50-X... UQFB UQFB-75-X... UQFB UQFB-00-X... UQFBH UQFBH-5... UQFBH UQFBH UQFBH UQFP UQFP-5... UQFP UQFP UQFP UQFPH UQFPH-5... UQFPH UQFPH UQFPH UQFPH-M UQFPH-M UQFPH-M-5... UQFPH-M-5... UQFPH-M UQFPH-M UQFPH-M UQFPH-M UQFPH-M UQFPH-M UQFP-M UQFP-M-5... UQFP-M UQFP-M UQFP-M Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

42

43

44 ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com ComEd /6

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work

More information

Louisiana/Mississippi. Area Catalog

Louisiana/Mississippi. Area Catalog Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Ohio Meter Mounting Equipment

Ohio Meter Mounting Equipment Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures

More information

REC Municipal Meter Mounting Equipment

REC Municipal Meter Mounting Equipment REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy

More information

Louisiana & Mississippi Area Catalog

Louisiana & Mississippi Area Catalog Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.483.534 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy

More information

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

PSE&G Long Island Meter Mounting Equipment

PSE&G Long Island Meter Mounting Equipment PSE&G Long Island Meter Mounting Equipment Milbank Overview Energy At Work since 927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential,

More information

Meter Mounting Equipment. Northern Indiana Public Service Co.

Meter Mounting Equipment. Northern Indiana Public Service Co. Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop

More information

Tennessee Area Meter Mounting Equipment

Tennessee Area Meter Mounting Equipment Tennessee Area Meter Mounting Equipment MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Meter Mounting Equipment DTE Energy Area

Meter Mounting Equipment DTE Energy Area Meter Mounting Equipment DTE Energy Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Consolidated Edison Orange & Rockland Meter Mounting Equipment

Consolidated Edison Orange & Rockland Meter Mounting Equipment Consolidated Edison Orange & Rockland Meter Mounting Equipment 2 MILBANK OVERVIE Milbank Overview Energy At ork since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Ameren Service Area Product Catalog

Ameren Service Area Product Catalog Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

Meter Mounting Equipment Commonwealth Edison

Meter Mounting Equipment Commonwealth Edison Meter Mounting Equipment Commonwealth Edison MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice

More information

Instrument Rated Metering Equipment

Instrument Rated Metering Equipment Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions

More information

Meter Mounting Equipment. GA/AL/FL Panhandle Area

Meter Mounting Equipment. GA/AL/FL Panhandle Area Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke

More information

Upstate New York Meter Mounting Equipment

Upstate New York Meter Mounting Equipment Upstate New York Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIE Milbank Overview Energy At ork since 97 Milbank builds

More information

Meter Mounting Equipment Florida Area Catalog

Meter Mounting Equipment Florida Area Catalog Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert

More information

Meter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market

Meter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market Meter Mounting Equipment Arkansas, W. Tennessee, N. Mississippi Market MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman

More information

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r0? 10:5 S3» ilm; , ' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *

More information

Meter Mounting Equipment

Meter Mounting Equipment Meter Mounting Equipment Central Hudson Service Area New York State Electric & Gas Service Area National Grid NY Service Area Rochester Gas & Electric Service Area MILBANK OVERVIEW MILBANK OVERVIEW Charles

More information

Meter Mounting Equipment Colorado Area

Meter Mounting Equipment Colorado Area Meter Mounting Equipment Colorado Area milbank overview milbank overview Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. aldrop, 9-00 Robert F. aldrop, II Chairman Katrina aldrop Henke Vice Chairman

More information

Meter Mounting Equipment Colorado Area

Meter Mounting Equipment Colorado Area Meter Mounting Equipment Colorado Area U80 PROFILE U8 Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements

More information

Commercial Pedestals Product Catalog

Commercial Pedestals Product Catalog Commercial Pedestals Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

Commercial & Industrial Product Catalog

Commercial & Industrial Product Catalog Commercial & Industrial Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation

More information

Commercial Pedestals Product Catalog

Commercial Pedestals Product Catalog Commercial Pedestals Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank provides the tools that empower life. We enable the amazing in countless everyday ways through

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION

More information

Enclosed Controls Product Catalog

Enclosed Controls Product Catalog Enclosed Controls Product Catalog Milbank Overview Energy At Work since 1927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Enclosed Controls Product Portfolio

Enclosed Controls Product Portfolio Enclosed Controls Product Portfolio Milbank is a family-owned American manufacturer headquartered in Kansas City, Mo. Since 1927, Milbank has set the standard for high quality metering equipment and enclosures.

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

(CT, NH, ME, RI, VT, MA)

(CT, NH, ME, RI, VT, MA) Selection and application guide For use in New England States (CT, NH, ME, RI, VT, MA) Meter Mounting Equipment www.talonmetering.com 1 Meter Mounting Equipment Table of Contents Service Rating Positions

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

CABINET OPTIONS AND DESIGNATORS CODE LETTERS

CABINET OPTIONS AND DESIGNATORS CODE LETTERS CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:

More information

Multiple Metering, Horizontal Gang - Non Lever Bypass

Multiple Metering, Horizontal Gang - Non Lever Bypass Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground

More information

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4

More information

Selection and Application Guide. Meter Mounting Equipment. For use in Iowa and Nebraska.

Selection and Application Guide. Meter Mounting Equipment. For use in Iowa and Nebraska. Selection and Application Guide Meter Mounting Equipment For use in Iowa and Nebraska www.talonmetering.com Meter Mounting Equipment Table of Contents Air Conditioning Disconnects Fused and Non-fused Rating

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

Modular Metering Construction Details

Modular Metering Construction Details GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single

More information

Section 6 Electric Metering: Residential

Section 6 Electric Metering: Residential Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.

More information

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX LAD05-9, CA 964 TITLE SHEET LAD05-9 SHEET INDEX 00 DEXTER AVE. SUITE 50 SEATTLE, WA 9809 PROJECT SUMMARY PROJECT DESCRIPTION COORDINATES LATITUDE: 33.678084 N LONGITUDE: -7.84858 W 0640 Sepulveda Blvd.

More information

6.1 Introduction Product Description... Application Description... Optional Features...

6.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................

More information

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SECTION 500 METERING AND ASSOCIATED EQUIPMENT SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.

More information

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................

More information

COMMERCIAL QUICK REFERENCE

COMMERCIAL QUICK REFERENCE COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

UNDERGROUND SERVICES - SECONDARY

UNDERGROUND SERVICES - SECONDARY UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service

More information

Selection and Application Guide For use in New England EQUIPMENT

Selection and Application Guide For use in New England EQUIPMENT Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,

More information

Switchgear Skid, C1192

Switchgear Skid, C1192 CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Multiple Metering, Vertical Gang

Multiple Metering, Vertical Gang Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or

More information

WPS SERVICE MANUAL. Section Amp and Smaller - Common

WPS SERVICE MANUAL. Section Amp and Smaller - Common Revised 01/2017 Section 2 200 AMP AND SMALLER - COMMON Page 1 of 17 Section 2 200 Amp and Smaller - Common 2-0 General Metering Requirements... 2 2-1 Basic Calculations... 4 2-2 100-200 Amp Single-Phase

More information

Volume 1 Residential and Light Commercial CA E December

Volume 1 Residential and Light Commercial CA E December Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT

Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT 2011 81 APPENDIX A: APPROVED METERING EQUIPMENT TABLE OF CONTENTS Approved Metering Equipment... A-1

More information

Customer Requirements Meter Socket Configurations

Customer Requirements Meter Socket Configurations Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements

More information

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...

More information

SPEEDFAX TM 2011 Meter Centers Contents

SPEEDFAX TM 2011 Meter Centers Contents SPEEDFAX TM 011 Meter Centers Contents Single and Multiple s - -19 General Information - -3 Single Position s - Residential Types -4-5 Multiple Position s Residential Types -6-7 Single Position s Commercial

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2 Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................

More information