1 BC Hydro Metering Kiosk BCH Metering and distribution kiosk built to BC Hydro distribution standards. Used for applications where secondary services are installed in weatherproof kiosks outside of a main facility. Features/Specification: Marine-grade aluminum construction Pad-lockable 3 point handle Service entrance rated main breaker Utlity approved CT enclosure Complete factory wiring for line & load lugs Pad-mount design Removable lifting ears Powder coated PC101 Grey Options: Viewing window on door Heater & thermostat Convenience receptacle PART NUMBER MAIN BREAKER PHASE VOLTAGE BCH A 1 120/240V BCH A 1 120/240V BCH A 1 120/240V BCH A 1 120/240V BCH A 3 120/208V BCH A 3 120/208V BCH A 3 347/600V BCH A 3 347/600V
2 CURRENT TRANSFORMER CABINETS CTC CT cabinets are used to meter single phase and three phase services where the CT s are not included within the meter base. These boxes are manufactured with either galvanized steel or aluminum and come with sealing screws, backpan for mounting CT s and internal mounting holes. Features/Specifications Galvanized steel or aluminum construction CSA Type 1 rated Designed to BC Hydro distribution standards Screw on cover Sealing screws Backpan Internal mounting holes H W FRONT VIEW (COVER REMOVED) D SIDE VIEW PART NUMBER HEIGHT WIDTH DEPTH MATERIAL SINGLE PHASE SERVICE THREE PHASE SERVICE CTCG GALVANIZED STEEL UP TO 400A UP TO 400A & BELOW 300V CTCA ALUMINUM UP TO 400A UP TO 400A & BELOW 300V CTCG GALVANIZED STEEL OVER 400A OVER 400A TO 800A CTCA ALUMINUM OVER 400A OVER 400A TO 800A CTCG GALVANIZED STEEL NOT USED OVER 800A CTCA ALUMINUM NOT USED OVER 800A Phone
3 FDC alid Farm Distribution Center The FDC Farm Distribution Center is a free standing, all encompassing, pad mount enclosure approved for use by local power utility and used primarily for power distribution in farms. Factory wired secondary lugs enable ease of multiple cable connections for larger sized wires. The weather proof design is ideal for outdoor use. Standard PC101 Grey powder coat paint provides a durable finish. Features/Specifications: Steel construction Padlockable 3-point handle Service entrance rated main breaker with lock off Ground bar with lugs for grounding circuits Utility approved CT Enclosure Complete factory wiring to line & load termination lugs Louvers with bug screen Pad mount design Removable lifting ears PC101 Grey powder coat finish Optional Features: Main Lugs Only breaker panel Sub-breakers as required Meter base Heater & thermostat BUSSING OPTION - PRE-DRILLED AND TAPPED BUS CONNECTION FOR CT S PART NUMBER AMP PHASE VOLTAGE HEIGHT WIDTH DEPTH FDC4-B / FDC6-B / FDC8-B / FDC10-B / FDC4-3-B /600* FDC6-3-B /600* FDC8-3-B /600* FDC10-3-B /600* * Also approved for use with 120/208V PART NUMBER AMP PHASE VOLTAGE HEIGHT WIDTH DEPTH FDC / FDC / FDC / FDC / FDC /600* FDC /600* FDC /600* FDC /600* * Also approved for use with 120/208V
4 Farm Distribution Center FDC CT CABINET LOAD FEEDER GROUND BAR MAIN FEEDER Typical FDC6 Configuration MLO PANEL 120/240V 600A CT CABINET LOAD FEEDER GROUND BAR MAIN FEEDER Typical FDC6 with MLO Breaker Panel Option
5 200A & 400A DIRECT BURIAL METERING PEDESTAL FMP-DB Features/Specifications: PENTA-BOLT Galvanized steel construction Service entrance rated Direct burial design 4-Jaw meter socket Line lugs rated for (1) 4AWG-600MCM or (2) 1/0 AWG-250MCM (400A only) Ground lug 28 ground stakes Complies to Fortis BC distribution standards PC101 Grey powder coat finish Optional Items: Grade Level Grade Level W FMP-DB-200 FMP-DB-400 ISOMETRIC VIEW PART NUMBER AMPS ABOVE GRADE HEIGHT TOTAL HEIGHT WIDTH DEPTH FMP-DB /2 FMP-DB
Joint Use Pedestals. alid AJP.
Joint Use Pedestals AJP This family of Joint Use Pedestals is an easily installed pedestal ideal for Power/Telephone or Cable/Power/ Telephone applications. These direct burial pedestals are available
More informationOptions. Meter base. Cooling Up fan to 22 kaic rated breakers SERVICE
ADPA ADPA alid ADPA This marine-grade aluminum distribution panel is generally used for highways lighting control. It is a base This mount marine-grade design with aluminum the cables distribution entering
More informationFeatures/Specifications FRONT VIEW (COVERS REMOVED)
BC HYDRO "L" BOX BCM The BCM enclosure is designed to comply with BC Hydro distribution standards for underground wiring to main feeds. The two piece design allows for right and left configurations with
More informationFeatures/Specifications FRONT VIEW (COVERS REMOVED)
BC HYDRO "L" BOX BCM The BCM enclosure is designed to comply with BC Hydro distribution standards for underground wiring to main feeds. The two piece design allows for right and left configurations with
More informationPARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR
PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR VPC-AA The VPC-AA Parking Lot Controller is an easily installed device designed for mid-sized parking lot installations. The weather proof design is ideal
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More informationSwitchgear Skid, C1192
CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts
More informationRequirements for Secondary Voltage Revenue Metering (750 V and less)
Requirements for Secondary Voltage Revenue Metering (750 V and less) To view the latest revision of this document go to: http://www.bchydro.com/ext/metering/ January 28, 2010 Copyright 2008 by BC Hydro.
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More informationCurrent Transformer, Termination & Disconnect Cabinets WE Energies Approved
Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...
More informationThree-Phase Pole Mounted Recloser
Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE
More informationCP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long
More informationELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016
DISTRIBUTED GENERATION CHAPTER 5 500. SCOPE This chapter includes distributed or customer-owned generation connected in parallel and operating with Alliant Energy s electric distribution system. For all
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal
DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationFeatures/Specifications FRONT VIEW (COVERS REMOVED)
BC HYDRO "L" BOX BCM The BCM enclosure is designed to comply with BC Hydro distribution standards for underground wiring to main feeds. The two piece design allows for right and left configurations with
More informationMarina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate
Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate All Power Pedestals Must Meet the Following: Part I. General: 1.1 General Requirements- A.) Shall be tested and certified
More informationLighthouse Power Pedestals,
Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized
More informationCABINET OPTIONS AND DESIGNATORS CODE LETTERS
CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:
More informationSERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company
More informationApproved Meter Sockets and Cabinets
Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to
More informationGeneral Specifications for Lighthouse Power Pedestal
Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4
More informationAGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS
Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals
Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More informationASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... - - - ASCO is there for you even when you re not - SERIES - SERIES SERIES -
More information320A Single Phase URD Meter Loop Installations
320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More informationUNDERGROUND SERVICES - SECONDARY
UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service
More informationMeter Installation. -and- Padmount Transformer Guide
Meter Installation -and- Padmount Transformer Guide Feb. 2016 METERING REQUIREMENTS The following information shall be used as a guide for installing metering equipment. A self-contained meter has all
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center
Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"
More informationME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position
LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble
More informationMETERING REQUIREMENTS
METERING REQUIREMENTS KUA will not accept a non-securable service trough entrance. That is, all enclosed conductors prior to the meter (line side) will be securable by and accessible to KUA personnel only.
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More informationMetering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS
Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationThree-Phase Ventilated
Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationRV Park Equipment Product Focus. Power Pedestals Distribution Equipment
RV Park Equipment Product Focus s Distribution Equipment Eaton Corporation RV Park Hookups Product Eaton offers a complete portfolio of electrical products for your RV project including pedestals, distribution
More informationELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016
UTILITY/CATV SERVICES CHAPTER 9 900. GENERAL A. Alliant Energy receives many requests for electric service from other utilities; telephone, telecommunications companies, cable television, the Department
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationSolar Power Switchgear & Energy Storage Renewable Energy Systems
7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH
More information*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*
Power Distribution System - 10KVA - (1) 480V Outlet - (6) 5-20 GFCI Outlets Part #: MGS-480.1X100A-10K-6X120 Made in the USA. The Larson Electronics MGS-480.1X100A-10K-6X120 heavy duty power transformer
More informationMicrolectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units
Microlectric CO Series Meter sockets A complete family of combination meter sockets and breaker units Outdoor, above-ground main breaker access increases safety Table of Contents Introduction... 3 Microlectric
More informationSUBSTATION VACUUM CIRCUIT BREAKER (38KV)
SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)
SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)
SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationApproved Contractor Construction e-guide Residential Commercial
Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13
More informationORDIC FIBERGLASS, INC.
Pedestals, Secondary ORDIC FIBERGLASS, INC. Pedestals, Plastic PSP-151530-MG-L6350 or PSP-151530-MG-L6600 Copolymer polypropylene pedestals are manufactured by an injection molding process with UV stabilized
More informationGRANITE ENCLOSURES MODEL NO. NPS Standard Features
MODEL NO. NPS-6-- --0666 Standard Features CSA and NEMA 3R (UL50) 1800 Amps @ 24Volt / 900 Amp @ 48Volt back up power Solid steel frame and shelf construction with 2 high sub-frame platform. Available
More informationTERMINATION ENCLOSURE OPTIONS
TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated
More informationGenerator Quick Connection Tap Box WM Series
Generator Quick Connection Tap Box WM Series Product Line Brochure www.apt-power.com 433 N. 36 th Street www.apt-power.com 433 North 36 th Street, Lafayette, Indiana 47905 Lafayette, IN 47905 Tel. 765-446-2343
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR
More informationPretest Module 24 Three-phase Service Entrance
Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals
Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41
More informationPEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location.
I N T R O D U C T I O N - M-1 RIGHTS: PEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location. NOTIFICATION: Customers planning to install or
More informationDetail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order
Detail Bill of Material Page 1 of 2 Project Name: Negotiation No: LAEC0706X6K1 General Order Alternate No: 0000 No: Item No. Qty Product Description 1 Pow-R-Line C Switchboard, Front Access/ Front and
More informationAPPENDIX B: LISTS OF APPROVED MATERIALS
APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS B1 Street Lighting MAY 2016 APPENDIX B1 STREETLIGHTING MATERIAL LIST 1.0 LIGHTING 1.1 Electrical Handholes CSA Precast concrete
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationCustomer Requirements Meter Socket Configurations
Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements
More informationCT Metering. CT Metering. Meter Mounting Equipment
Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationSingle-Phase Ventilated
Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION
More informationThree Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts
Three Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts Part #: EPSW-3PH-60-EB Page: 1 The EPSW-3PH-60-EB Three Phase Explosion Proof Switch by Larson Electronics is a
More informationGE 8000-Line Motor Control Centers
GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service
More informationTemporary Power Outlet Panels
Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Specifically For You Excerpt from Master Catalogue Circuit Breakers DIN rail mount, thermal/magnetic circuit breakers. Their compact dimensions, ease of mounting and excellent performance
More information75 KVA Transformer Power Distribution - 480V to 120/208V - Nema 3R V and 8 120V Outlets
75 KVA Transformer Power Distribution - 480V to 120/208V - Nema 3R - 6 208V and 8 120V Outlets Part #: MPD-480-200MB-75K-6X208-8X120 MADE IN THE USA This Larson Electronics 75KVA Power Distribution Substation
More informationNS Feeder pillar up to 3200A
NS Feeder pillar up to 3200A Advanced technology for low voltage, outdoor distribution Merlin Gerin Modicon Telemecanique Outdoor electrical distribution with advanced technology Merlin Gerin low voltage,
More informationAIR CORE REACTORS. Phoenix Electric Corporation
AIR CORE REACTORS Phoenix Electric Corporation PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed
More informationBYV Series Butterfly Valve Product Guide FLOW CONTROL
BYV Series Butterfly Valve Product Guide FLOW CONTROL 17 Q U A L I T Y S E R V I C E I N T E G R I T Y 1 OVERVIEW Engineered Hand Lever Design for Enhanced Strength and UV Performance Ergonomic Grip and
More informationSTOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION
CHAPTER 1 - GENERAL INFORMATION 100. Purpose 101. Codes and rules 102. Continuity of service 103. Frequency, Voltage, and Amperage Limitations 104. High voltages 105. Unusual capacity requirements 106.
More informationMarina Power and Lighting Equipment. Product Focus. Power Pedestals Distribution Equipment. High-Quality, Weatherproof Electrical Equipment
Marina Power and Lighting Equipment Product Focus Power Pedestals Distribution Equipment High-Quality, Weatherproof Electrical Equipment Eaton Corporation Marina Power and Lighting A Powerful Solution
More informationCustomer Requirements Downtown Secondary Network Service
Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard
More informationLOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA
LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution
More informationE Series Electric Actuators
ENGINEERING MANUAL 13560 Larwin Circle, Santa Fe Springs, CA 90670 Phone: (562) 802-2255 (800) 783-7836 Fax: (562) 802-3114 Netsite: www.svf.net E-mail: Sales@SVF.net E Series Electric Actuators 1/4 3
More informationTechnical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA
Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power
More informationPOWER PRODUCT Meter Centres Contents
POWER PRODUCT Meter Centres Contents General Specifications - Catalogue Numbering System - 40V Meter Centre Overview - Features & Benefits -3 Procedure -5 Switches and Tap Boxes -6 Meter Stacks -7 Socket
More informationVERTIV XTE 401 SERIES. Ordering Guide
VERTIV XTE 401 SERIES Ordering Guide VERTIV XTE 401 SERIES Description The Vertiv XTE 401 Series is a family of three small single sided low-cost indoor or outdoor rated aluminum enclosures. These versatile
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following models: 275/300REOZV 350/400REOZVC 450REOZVB Weather Sound Weather Features Critical silencer, flexible
More informationPower Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................
More informationElectric Service Standards
VI - 1 of 17 VI. METERING EQUIPMENT A. Equipment Furnished and Installed by FPL FPL provides and installs, at its expense, adequate metering instruments to measure the electric service used by the Customer.
More informationCOMMERCIAL QUICK REFERENCE
COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR
More information6.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................
More informationWOODS WIRE WOODS WIRE
INTERIOR HOUSEHOLD EXTENSION Power Tap Extension Cords 3-Outlet solid molded power taps 3-outlet compact design grounded 3-conductor molded plug wire gauge: 16-3 wire type: SPT-3 rated: 13A/125V CSA approved
More informationW Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications
W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications This table shows the optional items available on the different types of enclosures shown in this
More informationMidwest Electric Products. Temporary Power
Midwest Electric roducts Temporary ower Midwest Electric roducts Temporary ower Midwest Electric provides the temporary power needed by construction trades prior to permanent service equipment installation.
More informationPower Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................
More informationD2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal
More informationIndustrial Generator Set Accessories
Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 500REOZVB 550/600REOZV Weather Enclosure Sound Enclosure Weather Enclosure Features
More informationGenerator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More informationSOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS
SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial
More informationPower Distribution System kva transformer P to 120/240 1P - 20X 120 Outlets and 2X 240
Power Distribution System - 37.5 kva transformer - 480 1P to 120/240 1P - 20X 120 Outlets and 2X 240 Part #: MGS-30KVA-20X120-2X240 Page: 1 Made in the USA The Larson Electronics MGS-30KVA-20X120-2X240
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationTransmission & Distribution Glossary of Electrical Terms
Transmission & Distribution Glossary of Electrical s Breaker Panel Bushing Circuit Circuit Breaker Conductor Conduit Consumption Current Distribution Electricity (Static vs. Current) Electron Feeder The
More information