Joint Use Pedestals. alid AJP.
|
|
- Patrick Kevin Fox
- 5 years ago
- Views:
Transcription
1 Joint Use Pedestals AJP This family of Joint Use Pedestals is an easily installed pedestal ideal for Power/Telephone or Cable/Power/ Telephone applications. These direct burial pedestals are available in single, two way or three way configuration. The 14GA galvanized steel body construction offers additional corrosion resistance. PC115 Seafoam Green powder coat paint offers a durable finish. Features/Specification: Galvanized steel construction 3/4 Plywood panel in CATV/TEL sections Ground bar termination Grade level marked on pededstal Padlockable doors Removable side panel on TEL section Complies to Fortis, ATCO & City of Lethbridge distribution standards PC115 Seafoam Green powder coat finish Optional Items: Ground stakes Mounting hardware Street light base mounting bracket CATV PWR TEL Part Number AJP-0602 AJP-0605 Description Two Way Joint Use Pedestal Three Way Joint Use Pedestal H Dimensions W 32 D AJP-0609 Three Compartment Power Pedestal AJP-0605 AJP-0620 Secondary Connection Box For Mounting On Mini-Pad Transformer
2 AJP alid Joint Use Pedestals CATV PWR TEL PWR TEL AJP-0609 AJP-0602 AJP-0620 AJP-0604 AJP-LGS AJP-0608 Mounting Hardware Part Number AJP-LGS AJP-0604 AJP-0608 Description Ground Stake Ground Stake Anti-Frost Street Light Base Mounting Bracket
3 BC HYDRO "L" BOX BCM The BCM enclosure is designed to comply with BC Hydro distribution standards for underground wiring to main feeds. The two piece design allows for right and left configurations with one part number. The open bottom allows easy access for BC Hydro feeder cables. Features/Specifications 14 Gauge galvanized steel construction Two piece design allows right or left configuration Open bottom For 200, 400, 600 and 800A services D 1 TYP. 12 B A A E A 1 TYP. 18 FRONT VIEW (COVERS REMOVED) C SIDE VIEW PART NUMBER SWITCH SIZE A B C D E BCM A 48" 24" 30" 48" 72" BCM A 62" 24" 30" 48" 86" BCM A 62" 30" 36" 54" 92" Phone
4 JOINT USE UTILITY PEDESTAL JUB This joint use utility pedestal is designed to be used in the supply of multi-family dwellings and comes complete with a service entrance rated main disconnect. It is designed to fit directly on a precast base and provides multiple load terminals with underground feed. The rear section is used for telephone or cable terminations. Features/Specifications CSA Type 3R rated Enclosure made from 14 ga. Galvanized Steel Dimensions of 36 H x 38 W x 22 D Powder coat PC101 Grey Designed to fit Armtec # precast base Hinged main breaker cover Service entrance barrier with sealing screws Plywood backpan on TEL/CATV side Padlockable hasp on outer doors Double 250MCM - #6 termination lugs on incoming and secondary Double 250MCM - #6 ground lug Options PC136 Carbon Black powder coat: (Add -PC136 to P/N) Anti-graffiti coating Barrier to separate telephone and cable sections 3 phase models for 208V, 480V and 600V (Enclosure size may need to increase) PRODUCT SELECTION GUIDE PART NUMBER: 1. PRODUCT 2. MAIN BREAKER % RATING - 3. # OF INCOMING TERMINATIONS - 4. AMPACITY - 5. # OF SECONDARY TERMINATIONS SAMPLE PART NUMBER: JUB Product JUB Joint Use Utility Pedestal 2. Main Breaker % Rating 1 100% Rated Main Breaker 1L 100% Rated Main Breaker w/ Lock-out tab 8 80% Rated Main Breaker 8L 80% Rated Main Breaker w/ Lock-out tab 3. # Of Incoming Terminations 2 250mcm - # mcm - #6 Phone Main Breaker Ampacity A A A A A 5. # Of Secondary Terminations 4 250mcm - # mcm - # mcm - # mcm - #
5 Telecom Termination Pedestal SG This family of Telecom Termination Pedestals are an easily installed pedestal ideal for TV/Cable/ Telephone and also Fibre optics/cross Connect applications. These direct burial pedestals with ground stakes are available in single and double door designs as well as back to back configuration. The 14GA galvanized steel body construction offers additional corrosion resistance. PC116 Telco Green powder coat paint offers a durable finish. Features/Specification: 14 GA galvanized steel construction Padlockable hasp Ground stakes with mounting hardware included 5/8 Plywood panel Ground bar termination Louvers with filtered ventilation PC116 Telco Green powder coat finish Optional Items: SG6 Concrete pad mount Custom powder coat colours Part Number Description Number of Mounting Stakes SG-2 Single Sided, Single Door 2 SG-3 Single Sided, Single Door 2 SG-4 Double Sided, Single Door 2 SG-5 Single Sided, Double Door 2 SG-6 Single Sided, Double Door 3 H Dimensions W D Page 1 of 2
6 Telecom Termination Pedestal SG SG2 SG3 SG4 SG5 Page 2 of 2
7 COMPACT JOINT USE UTILITY PEDESTAL SJU This joint use utility pedestal is designed to be used in multi family dwellings where space restraints are required and comes complete with a service entrance rated main disconnect. It is designed to fit directly on a pre-form concrete base and provides multiple load terminals with underground feed. The rear section is used for telephone or cable terminations. Features/Specifications CSA Type 3R rated Enclosure made from 14 ga. Galvanized Steel Dimensions of 36 H x 25 W x 21 D Powder coat PC101 Grey Designed to fit Armtec # precase base Main breaker cover Service entrance barrier with sealing screws Plywood backpan on TEL/CATV side Padlockable hasp on outer doors 1 x double 600MCM - #2 lugs per phase/neutral on incoming. (8) 2/0 - # 14 ground connections points Options PC136 Carbon Black powder coat: (Add -PC136 to P/N) Anti-graffiti coating Lock-out tab on main breaker - Add `L` (Example: SJU1L ) 80% Rated Main Breaker 100% Rated Main Breaker PART NUMBER OUTGOING LUGS PER PHASE MAIN BREAKER PART NUMBER OUTGOING LUGS PER PHASE MAIN BREAKER SJU (4) 250mcm - #6 120/240V 200A 1PH SJU (6) 250mcm - #6 120/240V 200A 1PH SJU (8) 250mcm - #6 120/240V 200A 1PH SJU (4) 250mcm - #6 120/240V 250A 1PH SJU (6) 250mcm - #6 120/240V 250A 1PH SJU (8) 250mcm - #6 120/240V 250A 1PH SJU (4) 250mcm - #6 120/240V 300A 1PH SJU (6) 250mcm - #6 120/240V 300A 1PH SJU (8) 250mcm - #6 120/240V 300A 1PH SJU (4) 250mcm - #6 120/240V 350A 1PH SJU (6) 250mcm - #6 120/240V 350A 1PH SJU (8) 250mcm - #6 120/240V 350A 1PH SJU (4) 250mcm - #6 120/240V 400A 1PH SJU (6) 250mcm - #6 120/240V 400A 1PH SJU (8) 250mcm - #6 120/240V 400A 1PH SJU (4) 250mcm - #6 120/240V 200A 1PH SJU (6) 250mcm - #6 120/240V 200A 1PH SJU (8) 250mcm - #6 120/240V 200A 1PH SJU (4) 250mcm - #6 120/240V 250A 1PH SJU (6) 250mcm - #6 120/240V 250A 1PH SJU (8) 250mcm - #6 120/240V 250A 1PH SJU (4) 250mcm - #6 120/240V 300A 1PH SJU (6) 250mcm - #6 120/240V 300A 1PH SJU (8) 250mcm - #6 120/240V 300A 1PH SJU (4) 250mcm - #6 120/240V 350A 1PH SJU (6) 250mcm - #6 120/240V 350A 1PH SJU (8) 250mcm - #6 120/240V 350A 1PH SJU (4) 250mcm - #6 120/240V 400A 1PH SJU (6) 250mcm - #6 120/240V 400A 1PH SJU (8) 250mcm - #6 120/240V 400A 1PH Phone
Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE
BC Hydro Metering Kiosk BCH Metering and distribution kiosk built to BC Hydro distribution standards. Used for applications where secondary services are installed in weatherproof kiosks outside of a main
More informationOptions. Meter base. Cooling Up fan to 22 kaic rated breakers SERVICE
ADPA ADPA alid ADPA This marine-grade aluminum distribution panel is generally used for highways lighting control. It is a base This mount marine-grade design with aluminum the cables distribution entering
More informationFeatures/Specifications FRONT VIEW (COVERS REMOVED)
BC HYDRO "L" BOX BCM The BCM enclosure is designed to comply with BC Hydro distribution standards for underground wiring to main feeds. The two piece design allows for right and left configurations with
More informationFeatures/Specifications FRONT VIEW (COVERS REMOVED)
BC HYDRO "L" BOX BCM The BCM enclosure is designed to comply with BC Hydro distribution standards for underground wiring to main feeds. The two piece design allows for right and left configurations with
More informationME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position
LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble
More informationUNDERGROUND SERVICES - SECONDARY
UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service
More informationORDIC FIBERGLASS, INC.
Pedestals, Secondary ORDIC FIBERGLASS, INC. Pedestals, Plastic PSP-151530-MG-L6350 or PSP-151530-MG-L6600 Copolymer polypropylene pedestals are manufactured by an injection molding process with UV stabilized
More informationNOT FOR CONSTRUCTION ACCESS DOOR IS SECURED USING 1/4-20 TORX T27 SECURITY SCREWS.13 [3] STEEL ACCESS DOOR ACCESS DOOR - SEE DETAIL B
162 6.4 127.0 SECTION AA 38 1. 203 8.0 203 8.0 800 31. ACCESS DOOR IS SECURED USING 1/420 TORX T27 SECURITY SCREWS.13 [3] STEEL ACCESS DOOR OPTIONAL 2nd PHOTOEYE 124 60.0 238 9.4 19.8 DETAIL B COLUMN ACCESS
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationCP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long
More informationCABINET OPTIONS AND DESIGNATORS CODE LETTERS
CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More informationFor Sales & Information, Call Toll Free: (888)
Outline Dimensions Serial Number (2) 0.28" (7.1 mm) 0.56" (14 mm) 10.0" (254 mm) 2.87" (72.9 mm) (19 mm) 0.19"(4.8 mm) thick Enclosure 12.25" (311 mm) 13.75" (349 mm) 2.75" (69.9 mm) (19 mm) 6.50" (165
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationInstallation Instructions for the Powerslide RV Pedestal #
Installation Instructions for the Powerslide RV Pedestal #70-8760 Rev: 11/20/2017 Hazardous voltage. Can cause severe injury or death. Eaton Electrical Inc. strongly recommends that these products be installed
More informationVERTIV XTE 401 SERIES. Ordering Guide
VERTIV XTE 401 SERIES Ordering Guide VERTIV XTE 401 SERIES Description The Vertiv XTE 401 Series is a family of three small single sided low-cost indoor or outdoor rated aluminum enclosures. These versatile
More informationCOMMERCIAL QUICK REFERENCE
COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR
More informationApproved Contractor Construction e-guide Residential Commercial
Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13
More information9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.
Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals
Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents
More informationRequirements for Secondary Voltage Revenue Metering (750 V and less)
Requirements for Secondary Voltage Revenue Metering (750 V and less) To view the latest revision of this document go to: http://www.bchydro.com/ext/metering/ January 28, 2010 Copyright 2008 by BC Hydro.
More informationFROM B.C. HYDRO ENCLOSURE (SEE NOTE 4) RIGID CONDUITS (SEE NOTE 8) ALTERNATIVE TO LOAD BARRIER (SEE NOTE 7) SERVICE ENTRANCE ENCLOSURE
FROM B.C. HYDRO FOR OVERHEAD INSTALLATION ONLY DUCT SEAL (SEE NOTE 8) PULL BOX (SEE NOTE 5) PULL BOX (SEE NOTE 5) FROM B.C. HYDRO 7- REVISED NOTES & TABLES ON PAGES,3,4,5,.MARCH AJ - GENERAL REV.MA 08
More informationSwitchgear Skid, C1192
CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 24 14 600 VOLT DRAWOUT SWITCHGEAR PART 1 - GENERAL 1.01 SECTION INCLUDES: A. Individually mounted rear-accessible low voltage switchgear ANSI rated switchgear and low voltage power circuit breakers
More informationMEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV
CE--C-en-REV.04 2016.1 MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE- Metal Clad switchboards family are designed for use in public and industrial distribution system up to 40,5kV for the operation and
More informationGenerator Quick Connection Tap Box WM Series
Generator Quick Connection Tap Box WM Series Product Line Brochure www.apt-power.com 433 N. 36 th Street www.apt-power.com 433 North 36 th Street, Lafayette, Indiana 47905 Lafayette, IN 47905 Tel. 765-446-2343
More informationMini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications
Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More informationSECTION METAL LOCKERS. A. ADAAG - Americans with Disabilities Act, Accessibility Guidelines.
Section 10_51_13_MetalLockerPenco-ProTough_8-19-09 PART 1 GENERAL SECTION 10 51 13 METAL LOCKERS 1.01 SECTION INCLUDES A. Heavy Duty Welded Tubular Frame Lockers. B. Locker benches. 1.02 REFERENCES A.
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More informationMetering and Service Installation:
Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...
More information320A Single Phase URD Meter Loop Installations
320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal
More informationDetail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order
Detail Bill of Material Page 1 of 2 Project Name: Negotiation No: LAEC0706X6K1 General Order Alternate No: 0000 No: Item No. Qty Product Description 1 Pow-R-Line C Switchboard, Front Access/ Front and
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationMEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase
MEH Series Sectionalizing Enclosures Single-Phase and Three-Phase ABB MEH Sectionalizing Enclosures ABB s MEH Sectionalizing Enclosures provide an economical and safe sectionalizing tap point for underground
More informationSection 6 Electric Metering: Residential
Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationCONTENTS BY CHAPTER. Chapter 2: COMPANY EQUIPMENT ON CUSTOMER PREMISES
CONTENTS BY CHAPTER Chapter 1: GENERAL INFORMATION Chapter 2: COMPANY EQUIPMENT ON CUSTOMER PREMISES Chapter 3: SERVICE ENTRANCES Chapter 4: METERING INSTALLATION Chapter 5: CUSTOMER-INSTALLED SERVICE
More informationCOMPACT SUBSTATION GUIDE
COMPACT SUBSTATION GUIDE Certificate Number FM35831 1 The substation is a compact enclosure consisting of MV switchgear, a transformer and an LV switchboard located in three separate compartments which
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationVolume 1 Residential and Light Commercial CA E December
Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application
More informationAIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR
AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector
More informationMEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV
CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection
More informationFeatures/Specifications FRONT VIEW (COVERS REMOVED)
BC HYDRO "L" BOX BCM The BCM enclosure is designed to comply with BC Hydro distribution standards for underground wiring to main feeds. The two piece design allows for right and left configurations with
More informationModular Metering Construction Details
GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single
More informationPower Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................
More informationCurrent Transformer, Termination & Disconnect Cabinets WE Energies Approved
Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More information6.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................
More informationMaxSG Low Voltage Switchgear
Low Voltage Products & Systems Automation Technology MaxSG Low Voltage Switchgear ABB Automation Technologies MaxSG ABB Slide 2 June 2009 Product verview Key Features and Benefits Construction nstrumentation
More informationELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016
UTILITY/CATV SERVICES CHAPTER 9 900. GENERAL A. Alliant Energy receives many requests for electric service from other utilities; telephone, telecommunications companies, cable television, the Department
More informationPower Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................
More information7. Residential Single-Family and Duplex Buildings (Dwellings)
Sin g le -F a mily a n d Du p le x Bu ild in g s 2016 Electric Service Requirements, 2 nd Edition Section 7 Section 7 Residential Single-Family and Duplex Buildings (Dwellings) Directory Page 7.1 General
More informationSUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)
SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (38KV)
SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)
SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products
More information56-SDMS-07 REV. 01 SPECIFICATIONS FOR
56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice
More informationOBE-3 Outdoor Series
OBE-3 Outdoor Series Installation Guide WARNING: Serious Personal Injury Securely mount the enclsoure to the ground to prevent tipping when the battery trays are used. Failure to do so could lead to serious
More informationPower Mod. Introduction.
Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination
More informationAPPENDIX B: LISTS OF APPROVED MATERIALS
APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS B1 Street Lighting MAY 2016 APPENDIX B1 STREETLIGHTING MATERIAL LIST 1.0 LIGHTING 1.1 Electrical Handholes CSA Precast concrete
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationTable of Contents 1. SCOPE Toronto Hydro Requirements Enclosed Switchgear Ontario Electrical Safety Code SI Units..
Section Table of Contents Page 1. SCOPE 1 1.1 Toronto Hydro Requirements 1 1.2 Enclosed Switchgear.. 1 1.3 Ontario Electrical Safety Code.. 1 1.4 SI Units.. 1 2. PURPOSE. 1 3. DEFINITIONS. 2 4. EXTENT
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationMEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV
MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators,
More informationSTOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION
CHAPTER 1 - GENERAL INFORMATION 100. Purpose 101. Codes and rules 102. Continuity of service 103. Frequency, Voltage, and Amperage Limitations 104. High voltages 105. Unusual capacity requirements 106.
More informationLIFT STATION 11 ONE-LINE DIAGRAM
LAC JOB : 118-086 OSG-D-ELEC06.DWG LIFT STATION 11 ONE-LINE DIAGRAM DWG : SHEET : E15 33 47 NEW NEW GENERATOR PAD BOLLARD BOLLARD WETWELL ACCESS HATCH WETWELL OUTLINE HANDHOLE SEWER MANHOLE LIFT STATION
More informationPARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR
PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR VPC-AA The VPC-AA Parking Lot Controller is an easily installed device designed for mid-sized parking lot installations. The weather proof design is ideal
More informationPretest Module 24 Three-phase Service Entrance
Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?
More informationPEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location.
I N T R O D U C T I O N - M-1 RIGHTS: PEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location. NOTIFICATION: Customers planning to install or
More informationFAITA ENGINEERING PTE LTD
Enclosures Polyester Reinforced with Fiber Glass Enclosures IP-659 Moulded polyester reinforced with fiber glass enclosures Degree of protection : IP-659 Double insulation Self-extinguishing High mechanical
More information19 floor rack with steel door
2015 Telecommunication rack systems HETEL 1 19 floor rack with steel door Rack width 600 mm Rack width 800mm General features include a metal frame, 19 rails, roof, side and rear panels, door and plinth
More informationSingle-Phase Ventilated
Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationLow Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear
13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationRV Park Equipment Product Focus. Power Pedestals Distribution Equipment
RV Park Equipment Product Focus s Distribution Equipment Eaton Corporation RV Park Hookups Product Eaton offers a complete portfolio of electrical products for your RV project including pedestals, distribution
More informationDesign Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak
Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationSOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS
SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial
More informationSwitchgear. Low Voltage
January 2001 Vol. 1, Ref. No. [0923] -1 Low Voltage Switchgear Contents Description Page Magnum DS Metal-Enclosed Product Description........................................... -2 Application Description........................................
More informationCluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS Salsbury Industries is Officially Licensed by the U.S.P.S. to Manufacture Cluster Box Units Salsbury 3300 series CBU's are manufactured
More informationThree-Phase Ventilated
Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationFiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)
Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide) 13536-A Figure 1. ACE-200DS Enclosure With OCM-HD Panels Content Page INTRODUCTION... 2 1 PRODUCT DESCRIPTION...
More informationSIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A
Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat
More informationTRANSMISSION SYSTEMS
TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric
More informationSolar Power Switchgear & Energy Storage Renewable Energy Systems
7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH
More informationSIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points
Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity
More informationPower Distribution Enclosures. Pillar shells and in-ground feeder pillars
Power Distribution Enclosures Pillar shells and in-ground feeder pillars Lucy Zodion Power distribution enclosures for every market Lucy Zodion is the UK s leading provider of feeder pillars with a wide
More informationSOLID PHENOLIC LOCKERS 1 MOST COMPLETE LOCKER LINE AMERICA S MOST COMPLETE LOCKER LINE. Since 1936
TM AMERICA S MOST COMPLETE LOCKER LINE 1 Proudly AMERICA S Made in America MOST COMPLETE LOCKER LINE Since 1936 Superior Lockers for Superior Satisfaction VersaMax Solid Phenolic lockers are engineered
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationAIR CORE REACTORS. Phoenix Electric Corporation
AIR CORE REACTORS Phoenix Electric Corporation PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed
More informationThree-Phase Pole Mounted Recloser
Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE
More informationSECTION METAL LOCKERS. A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.
SECTION 10 51 13 METAL LOCKERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Heavy Duty Welded Gear Lockers. B. Locker benches. 1.02 REFERENCES A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.
More informationElectric Service Rules
2017 Electric Service Rules GENERAL INFORMATION TEMPORARY SERVICES OVERHEAD SERVICES UNDERGROUND SERVICES DISTRIBUTED GENERATION METERING HUD MANUFACTURED HOMES FARM SERVICES UTILITY/CATV SERVICES PRIMARY
More informationROOF HATCHES. Over 45 years of proven performance in Standard & Custom Designed Hatches SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES!
ROOF HATCHES SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES! Over 45 years of proven performance in Standard & Custom Designed Hatches ROOF HATCHES Better by design LEXCOR COMPANY PROFILE Lexcor was incorporated
More information7 Single Family Service
7 Single Family Service 7. General The location of the service entrance on the Customer s premises is an important consideration. For clearance and location information see section 5 (Clearances). Consult
More information