1 Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency n 60 Hz operation n Aluminum windings n 150ºC temperature rise n 220ºC insulation class standard n NEMA3R rated enclosures standard n Heat-cured ASA-61 gray powder coat finish n Cores of high quality electrical steel n Primary taps n Lugs provided for units up to and including 50 kva on catalog items Features, Functions, Benefits n Large connection compartment for ease of wiring and installation n Many sizes in stock and available for immediate shipment n Quiet operation for installation flexibility n Seismic certification for all units Standards n Meets DOE-2016 standard Part 431, Subpart K for energy efficiency n Built in accordance with NEMA, ANSI, UL and CSA standards Options and Accessories n Other sizes, voltages and temperature rises available n Copper windings n CE Marked units available as custom n Wall brackets available for units up to 75 kva Approvals 1-1
2 1-2 Single-Phase Ventilated Enclosure Figure Figure 24 Model Numbers Defined 421-TXXY-ABC Wall Mounting Bracket Kits Part Number Description Max Unit Wgt (lbs) For 15 kva units, 150 C rise For 16 to 75 kva units, 150 C rise 750 Wall Mounting Bracket Kits with Drip Pans For Single Phase units, 15 width For Single Phase units, 17 width For Single Phase units, 20 width For Single Phase units, 22 width 750 Lugs Part Number kva Primary Lug Qty Secondary Lug Qty 4PT-2007-LUG 15 # #2/ PT-2017-LUG 25 # MCM PT-2008-LUG 37.5 # MCM PT-2009-LUG 50 #2/ MCM PT-2018-LUG* 75 #2/ MCM * Must be ordered, not included on stock units kva Rating / XX Single-Phase, Ventilated Floor Mount Type C802 compliant 2 DOE compliant 9 kva Rating / XX Up to 1,650 kva available as specials Primary Secondary 120x / /240 2 Custom / x /240 5 Specials* 6 120x / /240 8 Custom 9 Wiring Aluminum 0 Copper 8 Temperature Rise 150 C C Shield No shield 0 Shield 5 *Suffix defined incrementally Jefferson Electric Dry-Type Transformers jeffersonelectric.com
3 Single-Phase Ventilated 1-3 Single-Phase General Purpose Transformers DOE Compliant Taps: 2.5% FCAN & 2.5% FCBN 240 x 480V 120/240V kva Catalog Number Enclosure Height (A) Width (B) Depth (C) (D) (E) Est Ship Wiring Wall Mounting Figure Wgt Diagram Bracket Kit S480F S480F S480F S480F S480F S480F n/a TBD S480F n/a TBD S480F n/a TBD S480F n/a TBD S480F n/a TBD TBD TBD TBD TBD TBD S480F n/a TBD TBD TBD TBD TBD TBD S480F n/a Taps: 2.5% FCAN & 2.5% FCBN 600V 120/240V S600E S600E S600E S600E S600E S600E n/a TBD S600E n/a TBD S600E n/a TBD S600E n/a TBD S600E n/a TBD TBD TBD TBD TBD TBD S600E n/a TBD TBD TBD TBD TBD TBD S600E n/a See website for additional kva, copper windings and temperature options. Housing dimensions subject to change without notice. Consult website or factory where dimensions are critical. Use the Find a Product tool for detailed specification sheets. For further information, contact an Application Engineer at , technical_services@jeffersonelectric.com
4 1-4 Single-Phase Ventilated Single-Phase General Purpose Transformers C802 Compliant Taps: 2.5% FCAN & 2.5% FCBN 240 x 480V 120/240V kva Catalog Number Enclosure Figure Height (A) Width (B) Depth (C) (D) (E) Est Ship Wgt Wiring Diagram Wall Mounting Bracket Kit S480F S480F S480F S480F S480F S480F n/a TBD TBD TBD TBD TBD TBD S480F n/a TBD TBD TBD TBD TBD TBD S480F n/a TBD TBD TBD TBD TBD TBD S480F n/a TBD TBD TBD TBD TBD TBD S480F n/a TBD TBD TBD TBD TBD TBD S480F n/a TBD TBD TBD TBD TBD TBD S480F n/a Taps: 2.5% FCAN & 2.5% FCBN 600V 120/240V S600E S600E S600E S600E S600E S600E n/a TBD TBD TBD TBD TBD TBD S600E n/a TBD TBD TBD TBD TBD TBD S600E n/a TBD TBD TBD TBD TBD TBD S600E n/a TBD TBD TBD TBD TBD TBD S600E n/a TBD TBD TBD TBD TBD TBD S600E n/a TBD TBD TBD TBD TBD TBD S600E n/a See website for additional kva, copper windings and temperature options. Housing dimensions subject to change without notice. Consult website or factory where dimensions are critical. Use the Find a Product tool for detailed specification sheets. For further information, contact an Application Engineer at , technical_services@jeffersonelectric.com Jefferson Electric Dry-Type Transformers jeffersonelectric.com
5 Single-Phase Ventilated 1-5 Wiring Diagrams S480F Wiring Diagram & Connections Wiring Diagram Primary: 240 x 480 Volts Secondary: 120/240 Volts PRIMARY H H2 S600E Wiring Diagram & Connections Wiring Diagram Primary: 600 Volts Secondary: 120/240 Volts PRIMARY X1 X2 X3 SECONDARY X4 Connections Primary Jumpers Between Taps Primary Lines Volts Left Coil Right Coil Connect To H1, H H1, H H1, H H1, H H1, H H1, H H1, H2 252 H2, 1 H1, 2 H1, H2 240 H2, 3 H1, 4 H1, H2 228 H2, 5 H1, 6 H1, H2 216 H2, 7 H1, 8 H1, H2 Secondary Volts Interconnect Secondary Lines Connect To 240 X2 to X3 X1, X4 120/240 X2 to X3 X1, X2, X4 120 X1 to X3 X2 to X4 X1, X4 SECONDARY Connections Primary Volts On Each Coil Primary Lines Jumper Taps To Connect To H1, H H1, H H1, H H1, H H1, H2 Secondary Volts Interconnect Secondary Lines Connect To 240 X2 to X3 X1, X4 120/240 X2 to X3 X1, X2, X4 120 X1 to X3 X2 to X4 X1, X4 More wiring diagrams can be found in catalog s appendix, section 15. Use the Find a Product tool on our website for detailed specification sheets. For further information, contact an Application Engineer at , technical_services@jeffersonelectric.com
6 1-6 Single-Phase Ventilated LIT Jefferson Electric Dry-Type Transformers jeffersonelectric.com
Three-Phase Ventilated
Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationTotally Enclosed Non-Ventilated
5 15 to 500 kva 5 Applications n Designed for commercial and industrial loads in challenging environments Specifications n NEMA3R rated enclosure n Single Phase units 15 through 100 kva n Three Phase units
More informationClass I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature
More informationJefferson Electric Class I Division 2 Transformers for hazardous locations
Class I Division 2 Jefferson Electric Class I Division 2 Transformers for hazardous locations Jefferson Electric offers a full line of Class I Division 2 transformers. Jefferson Electrics Class I Division
More information30 KVA Transformer - 480V 3 Phase to 208Y/120V - NEMA 3R Enclosure - Copper Windings
30 KVA Transformer 480V 3 Phase to 208Y/120V NEMA 3R Enclosure Copper Windings Part #: MT30KVA3P480V208.120CU Page: 1 MT30KVA3P480V208.120CU 30kVA Transformer 480V 3 Phase480V Delta Primary Voltage 208Y/120V
More information75 kva Transformer - 480V Delta Primary - 208Y/120 Wye-N Secondary - NEMA 3R - K-13 - Copper Winding
75 kva Transformer 480V Delta Primary 208Y/120 WyeN Secondary NEMA 3R K13 Copper Winding Part #: MTK13FP3P480D75KVA208Y.120N3RESCU Page: 1 The MTK13FP3P480D75KVA208Y.120N3RESCU 480 V Delta 3 Phase Energy
More information30kVA Transformer - 3 Phase Delta Primary - 380Y/220 or 400Y/230 Secondary - NEMA 3R
30kVA Transformer 3 Phase 480 Delta Primary 380Y/220 or 400Y/230 Secondary NEMA 3R Part #: MT480D30KVA380.400V Page: 1 The MT480D30KVA380.400V 480V 3 Phase Energy Efficient transformer from Larson Electronics
More informationDry Type Distribution Transformers
Low Temperature Rise SolaHD low temperature rise transformers feature a 220 C insulation system and temperature rise of only 80 C or 115 C under full nameplate load. Reduction in temperature rise increases
More information45 kva Isolation Transformer - 480V Delta Primary - 400V Delta Secondary - N3R - Copper Windings
45 kva Isolation Transformer 480V Delta Primary 400V Delta Secondary N3R Copper Windings Part #: MTDOE163P480D45KVA400DN3RCU Page: 1 The MTDOE163P480D45KVA400DN3RCU 480D 3 Phase Energy Efficient Isolation
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationDry Type Distribution Transformers
Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments. Encapsulation and rugged UL Listed/NEMA
More informationFeatures, Benefits and Functions
-8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor
More informationTransformers 6. Gross Automation (877)
Transformers 6 Hevi-Duty Family of Transformers Sola/Hevi-Duty offers a broad range of transformers to meet many applications. These dry-type transformers are offered encapsulated, ventilated or non-ventilated,
More informationWiring Diagram Number
General-Purpose Encapsulated Transformers.4 Single-Phase Encapsulated Type EP, 60 Hz 77 Volts to 10/40 Volts 1 Full Capacity Taps kva FCAN FCBN Type 40 x 40 Volts to 10/40 Volts Full Capacity Taps kva
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationDry Type Distribution Transformers
Dry Type Distribution Transformers 5 General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 15 through 500. Indoor and outdoor models available.
More informationMIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6
I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load
More informationDry-Type Transformers Mini-Power Centers
Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant
More informationTransformer Installation, Operation, and Maintenance Manual
Transformer Installation, Operation, and Maintenance Manual CONTENTS INTRODUCTION......................................... 2 INSPECTION UPON RECEIVING... 2 STORAGE...............................................
More information112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R
112.5 kva Transformer 480 Delta Primary 240/120V Secondary 60 Hz 3 Phase NEMA 3R Part #: MT112.5KVA480240.1203P Page: 1 The MT112.5KVA480240.1203P 480D 3 Phase Energy Efficient isolation transformer from
More informationDry Type Distribution Transformers
Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for hazardous locations as well as harsh industrial environments. Encapsulation and rugged UL Listed/NEMA
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More information112.5 kva Isolation Transformer - 440V Delta Primary - 110V Delta Secondary - NEMA 3R
112.5 kva Isolation Transformer 440V Delta Primary 110V Delta Secondary NEMA 3R Part #: MTISX3P440D112.5KVA110DN3R Page: 1 The MTISX3P440D112.5KVA110DN3R 440 V Delta 3 Phase Energy Efficient Distribution
More informationNon-Ventilated Automation Transformers 6
Non-Ventilated Automation Transformers 6 Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations (Class 1, Division 2, Group A-D) as well
More informationEfficiency is in our DNA
Efficiency is in our DNA EFFICIENCY IS IN OUR DNA EFFICIENCY AND ENERGY-SAVINGS IS PART OF OUR CULTURE From the day the company was founded in 1942, Marcus Transformer has focused its technology on providing
More information2 SLR Series Line Reactors... 50
Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...
More information75 kva Transformer - 208V Delta Primary Voltage - 480V Delta Secondary Voltage - NEMA 3R
75 kva Transformer 208V Delta Primary Voltage 480V Delta Secondary Voltage NEMA 3R Part #: MTATX3P208D75KVA480DN3R Page: 1 The MTATX3P208D75KVA480DN3R 208D 3 Phase Energy Efficient Transformer from Larson
More informationENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS
Hammond Power Solutions Inc. Page 1 of 1 ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS HPS Titan has been designed to operate in harsh environments/hazardous locations where dangerous gases, liquids,
More information90 kva Transformer - 208Y Wye-N Primary Voltage - 230Y Wye-N Secondary Voltage - NEMA 3R
90 kva Transformer 208Y WyeN Primary Voltage 230Y WyeN Secondary Voltage NEMA 3R Part #: MT208Y90KVA230Y3P Page: 1 The MT208Y90KVA230Y3P 208Y 3 Phase Energy Efficient Transformer from Larson Electronics
More information75 kva Isolation Transformer - 480Y Wye-N Primary - 208Y/120V Secondary - NEMA 3R Enclosure
75 kva Isolation Transformer 480Y WyeN Primary 208Y/120V Secondary NEMA 3R Enclosure Part #: MTISX3P480Y75KVA208Y.120N3R Page: 1 The MTISX3P480Y75KVA208Y.120N3R 480Y 3 Phase Energy Efficient Isolation
More information750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R
750 kva Transformer - 12470V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R Part #: MT-PMD-3P-12470D-750KVA-480Y.277-N3R Page: 1 The MT-PMD-3P-12470D-750KVA-480Y.277-N3R 12470D 3 Phase
More informationDistribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection
7 Distribution Dry Type Transformers 600 Volts Class Single and Three Phase 600 Volts Class Single Phase 0.25 167 KVA Three Phase 3 1000 KVA Features Standard units are UL listed and are designed in accordance
More informationGeneral Purpose Buck - Boost Wiring Diagrams... 86
SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for
More information1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled
1500 kva Pad Mount Transformer - 24940GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled Part #: MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R Page: 1 The MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R
More informationMidwest Dry Type Transformers
Midwest Electric Products Midwest Dry Type Transformers Reliable and Efficient Performance From a Name You Know DOE 2016 Efficiency Transformers Catalog General Information...2 General Purpose... 3 Single-Phase
More informationAC Line / Load Reactors
AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100
More informationHPS Fusion General Purpose Enclosed Transformer
HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio
More informationMiscellaneous. Unit Substation 600 Volts and Below. Sealed Mini Power-Zone Transformers Industrial Control
Table of Contents Section General Purpose Dry Type 600 Volts and Below General Purpose Transformer, see page -2 Sealed Transformer, see page -10 90701050D2 Industrial Control Transformer, see page - EE
More informationIndustrial Control Transformers
The SBE - Encapsulated, Copper Wound Series The SolaHD SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants.
More informationICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers
More informationIndustrial Control Transformers
Industrial Control Types MTE and MTK.1 Standards and Certifications................................. Catalog Selection.................................. Type MTE...............................................
More informationDry Type Distribution Transformers
K-Factor Transformers K-Factor transformers are designed to reduce the heating effects of harmonic currents created by loads like those shown in Chart A. The K-Factor rating is an index of the transformer
More informationUnit Substation Transformers 5 and 15 KV Class
Transformers 5 and 15 KV Class 85 General Information Description Federal Pacific unit substation transformers are available in a wide variety of types and ratings to provide reliable and versatile electrical
More informationDOE 2016 Environmental Benefits
TABLE OF CONTENTS DOE 2016 Efficiency Guidelines HPS DOE Compliant Products Features & Benefits Specifications & Accessories Part Guide Support & Resources Selection Tables - HPS Sentinel G Selection Tables
More informationTanning Bed Transformers
Tanning Bed Transformers Complete line of transformers designed specifically for the tanning industry. SolarTran Tanning Bed Transformers are specifically designed to serve the voltage transformation needs
More informationPRODUCT INFORMATION PACKET
PRODUCT INFORMATION PACKET Model No: 048S17D7204 Catalog No: D180 1/4,1725,DP,48Y,1/60/115 Self Cooled Regal and Marathon are trademarks of Regal Beloit Corporation or one of its affiliated companies.
More informationControl Circuit Transformers
Technical Data Control Circuit Transformers Bulletin Numbers 1497, 1497A, 1497B, 1497D Topic Page Summary of Changes 1 Control Circuit Transformers Product Overview 2 Bulletin 1497 Global Control Circuit
More informationDOE 2016 Environmental Benefits
TABLE OF CONTENTS DOE 2016 Efficiency Guidelines HPS DOE Compliant Products Features & Benefits Specifications & Accessories Part Guide Support & Resources Selection Tables - HPS Sentinel G Selection Tables
More informationVentilated Distribution Transformers
K-Factor Transformers K-Factor transformers are designed to reduce the heating effects of harmonic currents created by loads like those shown in Chart A. The K-Factor rating is an index of the transformer
More information500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled
500 kva Pad Mount Transformer - 12470V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled Part #: MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU Page: 1 The MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU
More informationCLIMAGUARD Outdoor Heat Exchangers
Product Overview : CLIMAGUARD Outdoor Heat Exchangers TX23 Model TX38 Model TX52 Model 132 Product Overview : Lab- and field-tested to seal out extreme weather CLIMAGUARD Outdoor Heat Exchangers PRODUCT
More informationProduct Information Packet VM HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1
Product Information Packet VM3534.33HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationEngineered solutions for power and the environment
Dongan Electric Mfg. Co General 2018 Your source for standard and custom transformers Engineered solutions for power and the environment Table of Contents Single Phase... 4 General Purpose... 5 Diagrams...
More informationBulletin A 1497B 1497D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer
Bulletin, A, B, D Transformers Product Overview Transformers Bulletin A B D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer Features Single,
More informationPrime Power Energie Systems Inc.
Prime Power Energie Systems Inc. C a s t C o i l Tr a n s f o r m e r s 100 kva to 30 MVA 2 3kV tto 34 2.3kV 34.5kV 5kV Extraordinary Quality, Reliability and Service Energy Efficient Low Total Owning
More informationSeries A DC Link Chokes
Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 INTRODUCTION...3 LIST PRICE / CROSS REFERENCE...4 SELECTION & LIST PRICE...5 208 VOLTS (60 HZ)...5 240 VOLTS (60 HZ)...6 400 VOLTS
More informationKuhlman Electric Corporation Volt Instrument Transformers
Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High
More informationCT Metering. CT Metering. Meter Mounting Equipment
Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination
More informationA. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.
1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More informationVentilated Distribution Transformers
K-Factor Transformers K-Factor transformers are designed to reduce the heating effects of harmonic currents created by loads like those shown in Chart A. The K-Factor rating is an index of the transformer
More informationThree Phase Transformers
Three Phase Transformers ontents Three Phase - General Purpose... 26 Three Phase - General Purpose Scott ed... 30 Three Phase - dditional ombinations vailable... 31 Three Phase - ion Diagrams... 32 Series
More informationVolt Instrument Transformers
www. kuhlman. com Kuhlman Electric Corporation Instrument Transformers 1 Table of Contents Description Model Page Wound, Oil-Filled VT (High Accuracy available) UTE-145-OH 3-4 Wound, Oil-Filled CCVT (High
More informationLow Voltage Lighting Power Supplies
SECTION VI LO VOLTAGE LIGTING TRANSFORMERS & POER SUPPLIES Low Voltage Lighting Power Supplies A greater selection for your indoor and outdoor low voltage lighting projects hy Low Voltage? Acme s Low Voltage
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More information1321 Power Conditioning Products
Technical Data 1321 Power Conditioning Products Don t Ignore the Cost of Power Line Disturbance Topic Page Product Overview 2 1321-3R and 3RA Series Line Reactors 3 1321 Reflective Wave Reduction (RWR)
More informationHPS EnduraCoil. Cast Resin Transformer
HPS EnduraCoil Cast Resin Transformer Hammond Power Solutions Inc. (HPS) is a leading manufacturer of standard and custom dry-type transformers in North America. Every HPS product is built with the quality
More informationAT30 SERIES BATTERY CHARGER
STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,
More informationUNDERSTANDING THE DOE 2016 IMPACT: ENERGY EFFICIENT TRANSFORMERS PRODUCT GUIDE
UNDERSTANDING THE DOE 2016 IMPACT: ENERGY EFFICIENT TRANSFORMERS PRODUCT GUIDE POWER CONVERSION AND PROTECTION SolaHD is at work for you on the facility floor, service entrance, branch panel, power distribution
More informationProduct Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1
Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationPRODUCT SPECIFICATIONS
KLR Series Three Phase Reactors PRODUCT SPECIFICATIONS Lifetime Warranty Performance Guarantee K-Rated, UL/ULC-Recognized; CSA-Certified 3 Phase, 600V Class Gapped Iron Core Inductor All Copper Windings
More informationProduct Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754
Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationPRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V
PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationHPS Fusion General Purpose Enclosed Transformer
HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio
More informationHPS Spartan Industrial Open Core & Coil Control Transformer
HPS Spartan Industrial Open Core & Coil Control Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the
More informationCTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY
PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 32000 GL 80 32002 GL 84 3999 GL 0 32004 GL 4 3200 GL 5 32003 GL 38
More informationThree-phase isolating transformers for photovoltaic and wind-power systems
BTTTFV SERIES VERY LOW LOSSES THREE PHASE "GREEN ENERGY" TRANSFORMERS DRY TYPE THREE PHASES TRANSFORMERS Rated frequency: 50/60Hz Rated primary voltage: 400V Rated secondary voltage: 400V Group: YNyn0
More informationTA Ta VA CTRL-XFRMR
3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationProduct Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1
Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationPH250MQMJ CNTL 250VA 240X X240
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PH250MQMJ CNTL 250VA 240X480-120X240 Hammond Power Solutions Catalog Number Manufacturer Description Weight per unit Product
More informationIndustrial Control Power Transformers Class MT
Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
More informationMTE AC Line / Load Reactors Price book
Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 REACTOR SELECTION & PRICING...4 208-240 VOLT (3-PHASE)...4 400 VOLT (50 HZ) USE FOR 380-415 VOLTS...5 480 VOLT (3-PHASE) REACTOR...6
More informationPower Voltage Transformers for Air Insulated Substations
Power Voltage Transformers for Air Insulated Substations Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the application of a
More informationMotors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters
Motors Automation Energy Transmission & Distribution Coatings GPH2 Combination Soft Starters GPH2 Combination Soft Starter 5to 350 HP The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationRENTAL DIESEL GENERATOR SET
RENTAL DIESEL GENERATOR SET MODEL HRIW-45 T4F 60Hz RENTAL/PRIME/STANDBY POWER EPA 36kW/60Hz/Rental/1800RPM VOLTAGE VAC 120/240V 120/208V 139/240V 277/480V 347/600V** RATING Prime Standby Prime Standby
More informationGENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17
GENERAL INFORMATION SECTION GUIDE SECTION 10 PAGE 1 DESCRIPTION SECTION NUMBER GENERAL INFORMATION... 10 POLE MOUNT TRANSFORMER SINGLE PHASE... 15 PAD MOUNT TRANSFORMER SINGLE PHASE..... 16 POLE MOUNT
More informationTERMINATION ENCLOSURE OPTIONS
TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated
More informationProduct Information Packet M HP,1425RPM,3PH,50HZ,56,3420M,TEFC,F1
Product Information Packet M3538-50.5HP,1425RPM,3PH,50HZ,56,3420M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless
More informationASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... - - - ASCO is there for you even when you re not - SERIES - SERIES SERIES -
More informationDiesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features
Specification sheet Diesel generator set 50 kw - 60 kw EPA emissions stationary Standby Description Cummins generator sets are fully integrated power generation systems providing optimum performance, reliability
More informationSECTION PADMOUNT TRANSFORMER - OIL FILLED
SECTION 26 12 19.01 PADMOUNT TRANSFORMER - OIL FILLED PART 1 GENERAL 1.1 DESCRIPTION: Padmount Transformers and Insulating Oil with underground primary and secondary connections for use in distribution
More informationCLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS
CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised
More informationCam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.
Cam-Lok Single Pole Connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity Cam-Lok connectors are the industry standard Cam-Lok
More informationGE 8000-Line Motor Control Centers
GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More informationAT10.1 SERIES FLOAT BATTERY CHARGERS. Advanced technology microprocessor control
Motive Power Systems Reserve Power Systems Special Power Systems Service AT10.1 SERIES LOAT BATTERY CHARGERS UL-1564 CSA-C22.2 Seismic Zone 4 Qualification Advanced technology microprocessor control Constant
More information