Industrial Generator Set Accessories

Size: px
Start display at page:

Download "Industrial Generator Set Accessories"

Transcription

1 Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following models: 275/300REOZV 350/400REOZVC 450REOZVB Weather Sound Weather Features Critical silencer, flexible exhaust connector, and rain cap. Lift base or tank-mounted, steel or aluminum construction with hinged and removable doors. Aluminum enclosures recommended for high humidity and/or high salt/coastal regions. Fade-, scratch-, and corrosion-resistant Kohler cream beige powder-baked finish. Lockable, flush-mounted door latches. Air inlet louvers and damper reduce rain and snow entry. High wind bracing, 241 kph (150 mph). Sound Features Includes all of the weather enclosure features with the substitution of an internal-mounted exhaust silencer and the addition of acoustic insulation material. Vertical air inlet and outlet hoods with 90 degree angles to redirect air and reduce noise. Acoustic insulation that meets UL 94 HF1 flammability classification. Sound-attenuated enclosure that offers an average of 75 db(a) sound level at 7 m (23 ft.) with acoustic insulation, acoustic-lined air inlet hoods, and acoustic-lined air discharge hood. Subbase Features The above-ground rectangular secondary containment tank mounts directly to the generator set, below the generator set skid (subbase). Both the inner and outer tanks have emergency relief vents. Flexible fuel lines are provided with subbase fuel tank selection. The secondary containment tank s construction protects against fuel leaks or ruptures. The inner (primary) tank is sealed inside the outer (secondary) tank. The outer tank contains the fuel if the inner tank leaks or ruptures. G /11i Page 1

2 Weather Fixed air flow inlet grille Critical silencer with tailpipe and rain cap Air inlet louvers Automatic door holders provide positive door positions during wind gusts Shown with fill/ spill containment option Fade-, scratch-, and corrosion-resistant powder-baked finish ADV-7007A-D Hinged and removable doors for ease of servicing Lockable, flushmounted door latches prevent tampering Oil drain and radiator drains Rodent guards and skid end caps prevent animal entry Horizontal air discharge through a removable air outlet grille ships assembled on subbase fuel tank or lifting base. Note: 450REOZVB shown, other models are similar. Weather Features Available in steel (14 gauge) or aluminum (2 mm [0.08 in.]) formed panel, solid construction. Preassembled package offering corrosion resistant (aluminum), dent resilient structure mounting directly to lift base or fuel tank. Powder-baked paint. Superior finish, durability, and appearance. External critical exhaust silencer. Offers maximum component life, operator safety, and includes rain shield and cap. Cooling/Combustion Air Intake. Weather protective designs using fixed air inlet louvers. Sized for maximum cooling airflow. Cooling Air Discharge. Weather protective design featuring horizontal air discharge. Exhausts air through a removable punched air outlet grille. NOTE: Installing an additional length of exhaust tail pipe may increase backpressure levels. Please refer to the generator set spec sheet for the maximum backpressure value. Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery. G /11i Page 2

3 Sound Automatic door holders provide positive door positions during wind gusts Fade-, scratch-, and corrosion-resistant powder-baked finish Enclosed insulated exhaust silencer for improved safety and noise reduction Vertical outlet hoods with 90 angles to redirect air and reduce noise Shown with fill/ spill containment option Openings at generator and radiator ends supply ample cooling air flow ADV-7007B-D Hinged and removable doors for ease of servicing Lockable, flushmounted door latches prevent tampering Acoustic insulation repels moisture absorption Oil and radiator drains Acoustic insulation meeting UL 94 HF1 flammability classification Rodent guards and skid end caps prevent animal entry ships assembled on subbase fuel tank or lifting base. Note: 450REOZVB shown, other models are similar. Sound Features Available in steel (14 gauge) or aluminum (2 mm [0.08 in.]) formed panel, solid construction. Preassembled package offering corrosion resistant (aluminum), dent resilient structure mounting directly to lift base or fuel tank. Powder-baked paint. Superior finish, durability, and appearance. Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design. Internal critical exhaust silencer offering maximum component life and operator safety. NOTE: Installing an additional length of exhaust tail pipe may increase backpressure levels. Please refer to the generator set spec sheet for the maximum backpressure value. Attenuated design. Acoustic insulation UL 94 HF1 listed for flame resistance. Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery. Cooling/combustion air intake. Attenuated models offering 90 vertical air inlet and gravity outlet 90 end hoods. Cooling air discharge. Attenuated models offering 90 vertical air outlet hoods. Redirects cooling air up and above enclosures to reduce noise ambient. G /11i Page 3

4 Weather and Sound Distribution panel heater Thermostat for ventilation fan DC light (qty. 4) Incandescent light (qty. 4) Ventilation fan ADV-7007A-D Relay for motorized dampers Battery charger TImer for DC lights 3-way switch with GFCI Panic bars Gravity air outlet louvers Note: 450REOZVB shown, other models are similar. Weather and Sound Options Basic Electrical Package (BEP) Distribution Panel/Load Center. Prewired AC power distribution of all factory-installed features including block heater, two GFCI-protected internal 120-volt service receptacles, internal lighting, and commercial grade wall switch. Load center powered by building source power and protected by a main circuit breaker, rated for 100 amps (single phase) or 125 amps (three phase) with capacity and circuit positions for future expansion. AC power distribution installed in accordance with NEC and all wiring within EMT thin wall conduit. Four incandescent or fluorescent lights located within UL-listed fixtures designed for wet locations. BEP, single-phase load center, 100 A, 120/240 VAC. BEP, three-phase load center, 125 A, 120/208/240 VAC. Heater Heater, 5 kw Ceiling Mounted. Electrical utility heater prewired to load center internal to enclosure. Rated at Btu. Includes adjustable louvers offering down flow and horizontal air tuning, built-in thermostat with automatic fan delay controls. Heater, single phase at 240 VAC. Heater, three phase at 208 or 240 VAC. DC Light Package DC Light Package (DLP). Prewired DC light package offering an economical alternative light source within the enclosure, as a complement to the BEP or a source of light when AC power is not available. Battery drain limited with fuse protection and controlled through a minute, spring-wound, no-hold timer. Miscellaneous Package Options Battery Charger, Mounted. Mounting and prewiring of DC output and AC input when optional BEP is selected. Battery charger located inside the enclosure and accessible through an access door. Block Heater with Junction Box. Factory-supplied block heater prewired to a junction box providing a convenient location for the customer wiring of the block heater. Heater, single phase at 240 VAC. Heater, three phase at 208 or 240 VAC. Design Options Aluminum Steel Panic Bar for each latching door. Provides additional safety for individuals working on the generator set while inside the enclosure. Motorized Variable Damper and Ventilation Motorized Air Inlets Aluminum construction Galvanized steel construction (available on sound enclosure only) Motorized Air Outlets (Aluminum construction) Ventilation Fan, 22.6 m 3 /min. (800 cfm) Wall Mount. Direct drive 3-blade 305 mm (12 in.) aluminum propeller fan with automatic shutters, driven by a totally enclosed air-over motor housed within a corrosion-resistant housing. Remote thermostatically controlled over a temperature range of 27 C to 54 C (80 F to 130 F). All components are prewired and installed. Gravity Air Outlet Louver. Louvers closed when unit is not running. After the unit starts, the forced cooling air opens the outlet louvers. G /11i Page 4

5 Subbase Fuel leak detection switch Electrical stub-up area open to bottom Fuel inlet from supply pump (with user-supplied day tank) Overflow to main tank (with user-supplied day tank) Low fuel level switch Additional fitting for optional accessory Removable fuel return diptube Basin drain Removable engine supply diptube Normal vent Fuel fill with lockable cap and 51 mm (2 in.) riser Fuel level gauge Emergency inner tank relief vent Emergency outer tank relief vent GM52140-B Note: 450REOZVB shown, other models are similar. Standard Subbase Features Extended operation. Usable tank capacity offers full load standby operation of up to 72 hours. UL listed. Secondary containment generator set base tank meeting UL 142 requirements. NFPA compliant. Designed to comply with the installation standards of NFPA 30 and NFPA 37. Integral external lift lugs. Enables crane with spreader-bar lifting of the complete package (empty tank, mounted generator set, and enclosure) to ensure safety. Emergency pressure relief vents. Meets UL requirements; ensures adequate venting of inner and outer tank under extreme pressure and/or emergency conditions. Normal vent with cap. Vent is raised above lockable fuel fill. Low fuel level switch. Annunciates a 50% low fuel level condition at generator set control. Leak detection switch. Annunciates a contained primary tank fuel leak condition at generator set control. Electrical stub-up. Fill/Spill Containment, 19 L (5 gal.). Above ground fill/spill container for fuel overfill spills during fill up. External mount or internal mount. Subbase Option G /11i Page 5

6 275REOZV 275/300REOZV and Subbase Specifications Weather and Subbase 3046 (119.9) 4131 (9107) 3676 (6104) 0 (0) 980 (259) (131.9) 5351 (11797) 4896 (10794) 305 (12) 2260 (597) (137.9) 5649 (12454) 5194 (11451) 457 (18) 2960 (782) (169) 2191 (86) 3656 (143.9) 5728 (12628) 5273 (11625) 610 (24) 3642 (962) (149.9) 5855 (12908) 5400 (11904) 762 (30) 5406 (1428) (155.9) 6224 (13722) 5769 (12718) 300REOZV 3046 (119.9) 4258 (9387) 3803 (8384) 0 (0) 980 (259) (131.9) 5478 (12077) 5023 (11074) 305 (12) 2260 (597) (137.9) 5776 (12734) 5321 (11731) 457 (18) 2960 (782) (169) 2191 (86) 3656 (143.9) 5855 (12908) 5400 (11904) 610 (24) 4028 (1064) (149.9) 6074 (13391) 5619 (12388) 762 (30) 5898 (1558) (155.9) 6478 (14282) 6023 (13278) 275REOZV Sound and Subbase 2729 (107.4) 4494 (9908) 3926 (8655) 0 (0) 980 (259) (119.4) 5714 (12597) 5146 (11345) 305 (12) 2260 (597) (125.4) 6012 (13254) 5444 (12002) 457 (18) 2960 (782) (266) 2191 (86) 3339 (131.4) 6091 (13428) 5523 (12176) 610 (24) 3642 (962) (137.4) 6218 (13708) 5650 (12456) 762 (30) 5406 (1428) (143.4) 6587 (14522) 6019 (13270) 300REOZV 2729 (107.4) 4621 (10188) 4053 (8935) 0 (0) 980 (259) (119.4) 5841 (12877) 5273 (11625) 305 (12) 2260 (597) (125.4) 6139 (13534) 5571 (12282) 457 (18) 2960 (782) (266) 2191 (86) 3339 (131.4) 6345 (13988) 5777 (12736) 610 (24) 4028 (1064) (137.4) 6437 (14191) 5869 (12939) 762 (30) 5898 (1558) (143.4) 6841 (15082) 6273 (13830) Notes: The first row for each model shows an enclosure with enclosure mounting lift base and without a subbase fuel tank. The estimated weight includes the generator set with oil and coolant, enclosure, fuel tank without fuel, and silencer. Refer to the respective ADV drawings for details. G /11i Page 6

7 450REOZVB and Subbase Specifications Weather and Subbase 450REOZVB with 5M4024 Alternator 3649 (143.6) 5266 (11585) 4663 (10260) 0 (0) 1696 (448) (155.6) 7041 (15489) 6438 (14164) 305 (12) 3093 (817) (161.6) 7377 (16230) 6774 (14905) 457 (18) 5042 (1332) (167.6) 7600 (16719) 6997 (15394) 610 (24) 7859 (17289) 7256 (15964) 4563 (179.6) (2701) (18879) 7978 (17554) 450REOZVB with 5M4027, 5M4028, 5M4030, 5M4162, 5M4270, 5M4272 Alternator 3649 (143.6) 5439 (11965) 4836 (10640) 0 (0) 1696 (448) (155.6) 7214 (15869) 6611 (14544) 305 (12) 3093 (817) (161.6) 7550 (16610) 6947 (15285) 457 (18) 5042 (1332) (167.6) 7773 (17099) 7170 (15774) 610 (24) 8032 (17669) 7429 (16344) 4563 (179.6) (2701) (19259) 8151 (17934) 450REOZVB with 5M4032, 5M4164 Alternator 3649 (143.6) 5571 (12255) 4968 (10930) 0 (0) 1696 (448) (155.6) 7346 (16159) 6743 (14834) 305 (12) 3093 (817) (161.6) 7682 (16900) 7079 (15575) 457 (18) 5042 (1332) (167.6) 7905 (17389) 7302 (16064) 610 (24) 8164 (17959) 7561 (16634) 4563 (179.6) (2701) (19549) 8283 (18224) Sound and Subbase 450REOZVB with 5M4024 Alternator 2879 (113.3) 5466 (12025) 4761 (10475) 0 (0) 1696 (448) (125.3) 7241 (15929) 6536 (14379) 305 (12) 3093 (817) (131.3) 7577 (16670) 6872 (15120) 457 (18) 5042 (1332) (137.3) 7800 (17159) 7095 (15609) 610 (24) 8059 (17729) 7354 (16179) 3793 (149.3) (2701) (19319) 8076 (17769) 450REOZVB with 5M4027, 5M4028, 5M4030, 5M4162, 5M4270, 5M4272 Alternator 2879 (113.3) 5639 (12405) 4934 (10855) 0 (0) 1696 (448) (125.3) 7414 (16309) 6709 (14759) 305 (12) 3093 (817) (131.3) 7750 (17050) 7045 (15500) 457 (18) 5042 (1332) (137.3) 7973 (17539) 7268 (15989) 610 (24) 8232 (18109) 7527 (16559) 3793 (149.3) (2701) (19699) 8249 (18149) 450REOZVB with 5M4032, 5M4164 Alternator 2879 (113.3) 5751 (12695) 5066 (11145) 0 (0) 1696 (448) (125.3) 7546 (16599) 6841 (15049) 305 (12) 3093 (817) (131.3) 7882 (17340) 7177 (15790) 457 (18) 5042 (1332) (137.3) 8105 (17829) 7400 (16279) 610 (24) 8364 (18399) 7659 (16849) 3793 (149.3) (2701) (19989) 8381 (18439) Notes: The first row for each model shows an enclosure with enclosure mounting lift base and without a subbase fuel tank. The estimated weight includes the generator set with oil and coolant, enclosure, fuel tank without fuel, and silencer. Refer to the respective ADV drawings for details. G /11i Page 7

8 350/400REOZVC and Subbase Specifications Weather and Subbase 350REOZVC with 4M4019, 4M4021, 4M4158, 4M4266 Alternator 3546 (139.6) 5135 (11309) 4532 (9984) 0 (0) 1696 (448) (151.6) 6910 (15213) 6307 (13888) 305 (12) 3093 (817) (157.6) 7246 (15954) 6643 (14629) 457 (18) 4471 (1181) (163.6) 7395 (16284) 6792 (14959) 610 (24) 5985 (1581) (169.6) 7600 (16731) 6997 (15406) 762 (30) 8926 (2358) (175.6) 8150 (17943) 7547 (16618) 350REOZVC with 5M4027, 5M4162, 5M4272 Alternator 3546 (139.6) 5185 (11420) 4582 (10095) 0 (0) 1696 (448) (151.6) 6960 (15324) 6357 (13999) 305 (12) 3093 (817) (157.6) 7296 (16065) 6693 (14740) 457 (18) 4471 (1181) (163.6) 7445 (16395) 6842 (15070) 610 (24) 5985 (1581) (169.6) 7650 (16842) 7047 (15517) 762 (30) 8926 (2358) (175.6) 8200 (18054) 7597 (16729) 400REOZVC with 4M4019, 4M4021, 4M4266, 5M4024 Alternator 3546 (139.6) 5135 (11309) 4532 (9984) 0 (0) 1696 (448) (151.6) 6910 (15213) 6307 (13888) 305 (12) 3093 (817) (157.6) 7246 (15954) 6643 (14629) 457 (18) 4471 (1181) (163.6) 7395 (16284) 6792 (14959) 610 (24) 5985 (1581) (169.6) 7600 (16731) 6997 (15406) 762 (30) 8926 (2358) (175.6) 8150 (17943) 7547 (16618) 400REOZVC with 5M4027, 5M4160, 5M4162, 5M4272 Alternator 3546 (139.6) 5185 (11420) 4582 (10095) 0 (0) 1696 (448) (151.6) 6960 (15324) 6357 (13999) 305 (12) 3093 (817) (157.6) 7296 (16065) 6693 (14740) 457 (18) 4471 (1181) (163.6) 7445 (16395) 6842 (15070) 610 (24) 5985 (1581) (169.6) 7650 (16842) 7047 (15517) 762 (30) 8926 (2358) (175.6) 8200 (18054) 7597 (16729) Notes: The first row for each model shows an enclosure with enclosure mounting lift base and without a subbase fuel tank. The estimated weight includes the generator set with oil and coolant, enclosure, fuel tank without fuel, and silencer. Refer to the respective ADV drawings for details. G /11i Page 8

9 350/400REOZVC and Subbase Specifications Sound and Subbase 350REOZVC with 4M4019, 4M4021, 4M4158, 4M4266 Alternator 3546 (139.6) 5309 (11694) 4604 (10145) 0 (0) 1696 (448) (151.6) 7084 (15598) 6379 (14049) 305 (12) 3093 (817) (157.6) 7420 (16339) 6715 (14790) 457 (18) 4471 (1181) (163.6) 7569 (16669) 6864 (15120) 610 (24) 5985 (1581) (169.6) 7774 (17116) 7069 (15567) 762 (30) 8926 (2358) (175.6) 8324 (18328) 7619 (16779) 350REOZVC with 5M4027, 5M4162, 5M4272 Alternator 3546 (139.6) 5359 (11805) 4654 (10256) 0 (0) 1696 (448) (151.6) 7134 (15709) 6429 (14160) 305 (12) 3093 (817) (157.6) 7470 (16450) 6765 (14901) 457 (18) 4471 (1181) (163.6) 7619 (16780) 6914 (15231) 610 (24) 5985 (1581) (169.6) 7824 (17227) 7119 (15678) 762 (30) 8926 (2358) (175.6) 8374 (18439) 7669 (16890) 400REOZVC with 4M4019, 4M4021, 4M4266, 5M4024 Alternator 3546 (139.6) 5309 (11694) 4604 (10145) 0 (0) 1696 (448) (151.6) 7084 (15598) 6379 (14049) 305 (12) 3093 (817) (157.6) 7420 (16339) 6715 (14790) 457 (18) 4471 (1181) (163.6) 7569 (16669) 6864 (15120) 610 (24) 5985 (1581) (169.6) 7774 (17116) 7069 (15567) 762 (30) 8926 (2358) (175.6) 8324 (18328) 7619 (16779) 400REOZVC with 5M4027, 5M4160, 5M4162, 5M4272 Alternator 3546 (139.6) 5359 (11805) 4654 (10256) 0 (0) 1696 (448) (151.6) 7134 (15709) 6429 (14160) 305 (12) 3093 (817) (157.6) 7470 (16450) 6765 (14901) 457 (18) 4471 (1181) (163.6) 7619 (16780) 6914 (15231) 610 (24) 5985 (1581) (169.6) 7824 (17227) 7119 (15678) 762 (30) 8926 (2358) (175.6) 8374 (18439) 7669 (16890) Notes: The first row for each model shows an enclosure with enclosure mounting lift base and without a subbase fuel tank. The estimated weight includes the generator set with oil and coolant, enclosure, fuel tank without fuel, and silencer. Refer to the respective ADV drawings for details. G /11i Page 9

10 KOHLER CO., Kohler, Wisconsin USA Phone , Fax For the nearest sales and service outlet in the US and Canada, phone KohlerPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore Phone (65) , Fax (65) DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the rightto change the design or specifications without notice and withoutany obligation or liability whatsoever. Contact your local Kohler generator set distributor for availability. 2004, 2005, 2008, 2009, 2011 by Kohler Co. All rights reserved. G /11i Page 10

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 500REOZVB 550/600REOZV Weather Enclosure Sound Enclosure Weather Enclosure Features

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Aluminum Sound Enclosure and Subbase Fuel Tank Package Applicable to the following models: KD800 - KD2500 Level 1 Sound Enclosure with Lift Base Sound Level 1 Enclosure

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Aluminum and Steel and Subbase Fuel Tank Package All Generator Set,, and Fuel Tank Options are UL 2200 Certified. Available Approvals and Listings - UL 2200 Listing

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Sound Enclosure and Subbase Fuel Tank Package Applicable to the following models: KD800 - KD2500 (includes KD1250-A) Level 1 Sound Enclosure with Lift Base Sound Level

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Packages Weather Enclosure Sound Enclosure Applicable to the following models: 650/750REOZDB Kohler enclosures protect

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather and Sound Enclosures Applicable to the following: 80-275REOZJD Weather Enclosure Standard Features Critical silencer, flexible exhaust connector, and rain cap.

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather and Sound Enclosures Applicable to the following: 20ROZJB 20-230REOZJB 80-200REOZJC Kohler enclosures protect stationary generator sets from the elements, animal

More information

Model: 180REOZJD. Standard Features. Ratings Range 60 Hz Standby: kw kva Prime: kw kva Generator Set Ratings

Model: 180REOZJD. Standard Features. Ratings Range 60 Hz Standby: kw kva Prime: kw kva Generator Set Ratings Model: 180REOZJD 208-600 V Diesel Ratings Range 60 Hz Standby: kw 145--180 kva 181--225 Prime: kw 135--165 kva 169--206 Standard Features Kohler Co. provides one-source responsibility for the generating

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather Housings Applicable to the following: 200REOZPB 230-300REOZDB 230-450REOZDD 350/400REOZD 350/400REOZDC 450REOZDB Kohler weather housings protect stationary

More information

C13 / C15 / C18 SOUND ATTENUATED ENCLOSURES

C13 / C15 / C18 SOUND ATTENUATED ENCLOSURES / / SOUND ATTENUATED ENCLOSURES US Sourced Diesel Generator Set - 750 60 Hz Image shown may not reflect actual configuration Features Robust / Highly Corrosion Resistant Construction Factory installed

More information

C13/C15/C18 Sound Attenuated Enclosures. Features. Enclosures. U.S. Sourced Diesel Generator Set kw 60 Hz

C13/C15/C18 Sound Attenuated Enclosures. Features. Enclosures. U.S. Sourced Diesel Generator Set kw 60 Hz // Sound Attenuated Enclosures U.S. Sourced Diesel Generator Set - kw 60 Hz Image shown may not reflect actual configuration Features Robust/Highly Corrosion Resistant Construction Factory installed on

More information

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps 220/ / / / /

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps 220/ / / / / KDxxxx-YF designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 1032--1152 kva 1290--1440 Prime: kw 960--1040 kva 1200--1300 Standard Features D Kohler Co. provides one-source

More information

GP-C30-D6. CUMMINS 4B3.9G2 Diesel Engine STAMFORD CUMMINS PI144F Alternator DEEPSEA DSE7320 Controller

GP-C30-D6. CUMMINS 4B3.9G2 Diesel Engine STAMFORD CUMMINS PI144F Alternator DEEPSEA DSE7320 Controller GP-C30-D6 28 KW CUMMINS GENERATOR 28 KW 35 KVA CUMMINS Diesel Generator Set, Fully packaged: CUMMINS Heavy duty diesel engine, 4 stroke, 1800rpm, Electronic STAMFORD CUMMINS alternator. IP23 protection,

More information

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps 220/ / / / /

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps 220/ / / / / KDxxxx-YF designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 1200 kva 1500 Prime: kw 1080 kva 1350 Standard Features D Kohler Co. provides one-source responsibility for

More information

Ratings Range 50 Hz Standby: kw kva Prime: kw kva Standard Features. General Specifications

Ratings Range 50 Hz Standby: kw kva Prime: kw kva Standard Features. General Specifications KDxxxx-YF designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 2128--2240 kva 2660--2800 Prime: kw 1800--2032 kva 2250--2540 Standard Features D Kohler Co. provides one-source

More information

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps 220/ / / / /

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps 220/ / / / / KDxxxx-YF designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 856--880 kva 1070--1100 Prime: kw 768--792 kva 960--990 Standard Features D Kohler Co. provides one-source responsibility

More information

GP-J200-60T4F. JOHN DEERE 6068HFG Engine US EPA Tier 4 FINAL LEROY SOMER TAL-046-C Alternator DEEPSEA DSE7320 Controller

GP-J200-60T4F. JOHN DEERE 6068HFG Engine US EPA Tier 4 FINAL LEROY SOMER TAL-046-C Alternator DEEPSEA DSE7320 Controller GP-J200-60T4F 200 KW JOHN DEERE GENERATOR 200 KW 250 KVA JOHN DEERE Diesel Generator Set, Fully packaged: JOHN DEERE Heavy duty diesel engine, 4 stroke, 1800rpm, Electronic US EPA Tier 4 FINAL

More information

KH06810TO4D 230/ / / / /

KH06810TO4D 230/ / / / / KDxxxx-YF designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 1360--1440 kva 1700--1800 Prime: kw 1240--1296 kva 1550--1620 Standard Features D Kohler Co. provides one-source

More information

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications. KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 830--900 kva 1038--1125 Prime: kw 750--810

More information

KH04830TO4D 230/ / / / /

KH04830TO4D 230/ / / / / KDxxxx-YF designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 760--800 kva 950--1000 Prime: kw 680--720 kva 850--900 Standard Features D Kohler Co. provides one-source responsibility

More information

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications. KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 1180--1250 kva 1475--1562 Prime: kw 1070--1120

More information

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications. Standard Features

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications. Standard Features KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 720--800 kva 900--1000 Prime: kw 640--720

More information

Ratings Range 60 Hz Standby: kw kva Prime: kw kva Standard Features. General Specifications

Ratings Range 60 Hz Standby: kw kva Prime: kw kva Standard Features. General Specifications KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 830--900 kva 1038--1125 Prime: kw 750--810

More information

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications. KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 1180--1250 kva 1475--1562 Prime: kw 1070--1120

More information

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps

Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps kw/kva Amps kw/kva Amps KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 1990--2000 kva 2488--2500 Prime: kw 1810

More information

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications. KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 2250--2500 kva 2812--3125 Prime: kw 2050--2270

More information

KH08430TO4D 277/ / / / /

KH08430TO4D 277/ / / / / KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 2210--2250 kva 2762--2812 Prime: kw 1980--2040

More information

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications.

Ratings Range 60 Hz Standby: kw kva Prime: kw kva General Specifications. KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 1180--1250 kva 1475--1562 Prime: kw 1070--1120

More information

KH05520TO4D 254/ / / / /

KH05520TO4D 254/ / / / / KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 975--1000 kva 1219--1250 Prime: kw 810--900

More information

Ratings Range 60 Hz Standby: kw kva Prime: kw kva Standard Features. General Specifications

Ratings Range 60 Hz Standby: kw kva Prime: kw kva Standard Features. General Specifications KDxxxx designates a generator set with a Tier 2 EPA-Certified engine. KDxxxx-F designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 720--800 kva 900--1000 Prime: kw 640--720

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Remote Radiator System Applicable to the following models: 400--1300REZCK 500--1000REZK Kohler Co. offers remote radiators for use with unhoused generator sets. The

More information

KD SERIES GENERATORS. for Industrial Power Systems

KD SERIES GENERATORS. for Industrial Power Systems KD SERIES GENERATORS for Industrial Power Systems TOTAL SYSTEM INTEGRATION Every detail down to the last bolt. This isn t your typical power system. It s a KOHLER industrial power system which means it

More information

ENCLOSURES. WEATHER PROTECTIVE and SOUND ATTENUATED. three levels of sound attenuation. D40-6 to D200-2 D40-6s to D100-6S.

ENCLOSURES. WEATHER PROTECTIVE and SOUND ATTENUATED. three levels of sound attenuation. D40-6 to D200-2 D40-6s to D100-6S. WEATHER PROTECTIVE and SOUND ATTENUATED ENCLOSURES three levels of sound attenuation D-6 to D200-2 D-6s to D100-6S Picture shown may not represent actual package. Features HIGHLY CORROSION RESISTANT CONSTRUCTION

More information

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A ELECTRIC POWER - Technical Spec Sheet STANDARD 264 ekw/ 330 kva/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor Rating Type: STANDBY Fuel Strategy: LOW FUEL CONSUMPTION 264 ekw/ 330 kva 50 Hz/ 1500 rpm/ 400

More information

enclosures and tanks kw gensets Specification sheet

enclosures and tanks kw gensets Specification sheet Specification sheet Enclosures and s 35-230 kw gensets Enclosure features 14-gauge, low carbon, hot-rolled ASTM A569 steel construction (panels) 12-gauge, low carbon, hot-rolled ASTM A569 steel construction

More information

Enclosures. Weather Protective and Sound Attenuated Enclosures D40-6 to D200-2 D40-6S to D100-8S. Features

Enclosures. Weather Protective and Sound Attenuated Enclosures D40-6 to D200-2 D40-6S to D100-8S. Features s Weather Protective and Sound Attenuated s D40-6 to D-2 D40-6S to D100-8S Picture shown may not reflect actual configuration Features Highly Corrosion Resistant construction Stainless steel flush fitting

More information

EMERGENCY GENERATOR SET

EMERGENCY GENERATOR SET PART 8.1: EMERGENCY GENERATOR SET PART 1 - GENERAL I SCOPE A. This specification covers the design, furnishing, installation and start up of a factory built, production tested, operable, liquid cooled

More information

Dual wall sub-base diesel fuel tanks -

Dual wall sub-base diesel fuel tanks - Specification sheet Dual wall sub-base diesel fuel tanks - 10-125 kw generator sets Description Cummins offers two series of fuel tanks (basic series and regional series) for the 10~125 kw diesel generator

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A 528 ekw/ 660 kva 50 Hz/ 1500 rpm/ 400 V Metric English Package Performance Genset Power Rating with Fan @ 0.8 Power Factor 528 ekw Genset Power Rating 660 kva Aftercooler (Separate Circuit) N/A N/A Fuel

More information

APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ

APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ BARTONVILLE * CEDAR RAPIDS * DAVENPORT * EAST PEORIA * HANNIBAL * MOBERLY * ROCK FALLS * SPRINGFIELD * URBANA APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ FEATURES: EMISSIONS: EPA Tier 3 Certified at 60Hz

More information

TT /13b INSTALLATION INSTRUCTIONS. Introduction

TT /13b INSTALLATION INSTRUCTIONS. Introduction TT-5 /b INSTALLATION INSTRUCTIONS Original Issue Date: 5/09 Model: 0RESA, 0REYG, 0RES, 0RYG, and RGEN0 Market: Residential/Commercial Subject: Oil Makeup Kits GM654 -KP, GM654-KP, and GM8987-S Introduction

More information

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A 360 ekw/ 450 kva 50 Hz/ 1500 rpm/ 400 V Metric English Package Performance Genset Power Rating with Fan @ 0.8 Power Factor 360 ekw Genset Power Rating 450 kva Aftercooler (Separate Circuit) N/A N/A Fuel

More information

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range Sound Attenuated Level 2 Enclosures 24-220 kva Range The sound attenuated Level 2, factory installed enclosures incorporate internally mounted critical level silencers. They are the premium enclosure offering

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Silencers and Exhaust Systems Kohler Co. offers silencers rated for hospital, critical, residential, and industrial applications and stainless steel flexible exhaust

More information

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant)

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant) Sound Attenuated 50 Hz / 60 Hz These sound attenuated, factory installed enclosures incorporate internally mounted super critical level silencers, designed for safety and aesthetic value on integral fuel

More information

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure PRO275-2 (EUIIIa Compliant) 50/60Hz Switchable Rating Prime Product 275 kva / 220 kwe KEY FEATURES Rental Ready Features Forklift pockets Fully certified dual point lifting Integrated heavy duty drag bar

More information

TT /17c INSTALLATION INSTRUCTIONS. Introduction. Power Tools Required

TT /17c INSTALLATION INSTRUCTIONS. Introduction. Power Tools Required TT-39 8/7c INSTALLATION INSTRUCTIONS Original Issue Date: 4/02 Model: Model KC, KS, and KEP Automatic Transfer Switches Market: Transfer Switches Subject: User Interface Cover Kits GM22703-KP and GM22703-KP3

More information

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure PRO100-2 (EUIIIa Compliant) 50/60 Hz Switchable Rating Prime Product 100 kva / 80 kwe KEY FEATURES Rental Ready Features Forklift pockets Fully certified single point lifting eye Integrated heavy duty

More information

Dual XQ350 Rental Package

Dual XQ350 Rental Package Dual XQ350 Rental Package SOUND ATTENUATED 700 kw 60 Hz 700 kv A 50 Hz Prime Power TWO CATERPILLAR 3406 TA ENGINES In-Line 6, Four-Stroke-Cycle Diesel Aspiration...Turbocharged/Aftercooled Bore mm (in)...137

More information

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby* DIESEL GENERATOR SET DE110E2 EU stage II emissions compliant. Output Ratings Generator Set Model - 3 Phase Prime* Standby* 400/230 V, 50 Hz 100.0 kva 80.0 kw 480/277 V, 60 Hz 113.0 kva * Refer to ratings

More information

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage 970kW AGG 1000 Engine : Alternator : Control System : GUASCOR LEROY SOMER P 732 control system This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

Magnum Mobile Generator MMG235 Specifications

Magnum Mobile Generator MMG235 Specifications Customer Driven Unsurpassed Value Magnum Mobile Generator MMG235 Specifications ENGINE John Deere PE6068HF485 - turbocharged, diesel engine o Prime - 286 hp @ 1800 rpm o Standby - 315 hp @ 1800 rpm o 6

More information

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) PRO60-2 (R96 EUIIIa Equivalent) 50/60 Hz Switchable Rating Prime Product 60 kva / 48 kwe KEY FEATURES Rental Ready Features 24 hour dual wall tankbase Forklift pockets Fully certified single point lifting

More information

Modular Acoustic Enclosures

Modular Acoustic Enclosures Modular Acoustic Enclosures 350 750 kva Range www.fgwilson.com The innovative and functional design of the 350 750 kva enclosure range ensures performance in the harshest of environments. Extremely durable

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range Sound Attenuated Level 2 24 220 kva Range The sound attenuated Level 2, factory installed enclosures incorporate internally mounted critical level silencers. They are the premium enclosure offering for

More information

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model

More information

Modular Acoustic Enclosures

Modular Acoustic Enclosures Modular Acoustic Enclosures 24 220 kva Range (CAL / CALG) www.fgwilson.com The compact modular design of the 24 220 kva CAL and CALG enclosures ensure optimum performance in the harshest of environments.

More information

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz SD020 2.4L Industrial Diesel Generator Set EPA Certified Stationary Emergency SD020 20 kw 1 of 6 Power Rating 20 kw 25 kva 60 Hz Prime Power Rating* 18 kw 23 kva 60 Hz *EPA Certified Prime ratings are

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

MMG45IF4. Mobile Generator. Engine. Generators. System Output. System Controls MMG45IF4

MMG45IF4. Mobile Generator. Engine. Generators. System Output. System Controls MMG45IF4 1 of 5 Generators Isuzu 4LE2XAGV01 - turbocharged, aftercooled diesel engine Prime 57 hp, 42.8kWm @ 1800 rpm Standby 63.7 hp, 47.5 kwm @ 1800 rpm 4 cylinder 2.2 L displacement EPA Tier IV approved and

More information

RENTAL DIESEL GENERATOR SET

RENTAL DIESEL GENERATOR SET RENTAL DIESEL GENERATOR SET MODEL HRIW-45 T4F 60Hz RENTAL/PRIME/STANDBY POWER EPA 36kW/60Hz/Rental/1800RPM VOLTAGE VAC 120/240V 120/208V 139/240V 277/480V 347/600V** RATING Prime Standby Prime Standby

More information

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) 50/60 Hz Switchable Rating Prime Product 150 kva / 120 kwe KEY FEATURES Rental Ready Features Forklift pockets Fully certified single point lifting

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353

More information

Home About Us Products & Services Search Contact Us

Home About Us Products & Services Search Contact Us 1 of 2 Home About Us Products & Services Search Contact Us Inlet Sets More related links... Standard Duty Square & Rectangular Inlet Sets Inlet Grates & Frames Trench Grating & Inlet Sets Trench Grating

More information

60 Hz FEATURES. Exclusively from your Caterpillar dealer

60 Hz FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T O R S E T S STANDBY PRIME 60 Hz 60-100 kw 54-90 kw Model Standby Prime kw (kva) kw (kva) D60P4S* 60 (60) 54 (54) D75P3 75 (93.8) 68 (85) D80P4* 80 (100) 72 (90) D75P1S 75 (75)

More information

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw SG/PG Series 400 kva 21.9L Industrial Spark-Ignited Generator Set Generac International Products 50 Hz *Built in the USA using domestic and foreign parts Image used for illustration purposes only Power

More information

Service Parts. Doosan 11.1 L. Engine. Engine Model: Generator Models: 180/200REZX 180/200RZX TP /09

Service Parts. Doosan 11.1 L. Engine. Engine Model: Generator Models: 180/200REZX 180/200RZX TP /09 Service Parts Engine Engine Model: Doosan. L Generator Models: 80/00REZX 80/00RZX TP-0 /09 Table of Contents Introduction... Numbering System Significance... Illustrations... How to Find Part Numbers...

More information

SPECIAL SPECIFICATION 8334 Packaged Engine Generator

SPECIAL SPECIFICATION 8334 Packaged Engine Generator 2004 Specifications CSJ 0196-07-027 SPECIAL SPECIFICATION 8334 Packaged Engine Generator 1. Description. Furnish and install packaged engine-generator of the types and ratings shown on the plans. Where

More information

TERM OF USE Standard reference conditions ESP/PRP 25 C /25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

TERM OF USE Standard reference conditions ESP/PRP 25 C /25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity. J60UC3 60KW GENERATOR 60 KW / 75 KVA DIESEL GENERATOR SET, FULLY PACKAGED: JOHN DEERE Heavy duty diesel engine, 4 stroke, 1800rpm, Turbo LEROY SOMER brushless alternator. IP23 protection, Insulation

More information

Modular Acoustic Enclosures

Modular Acoustic Enclosures Modular Acoustic Enclosures 225 375 kva Range www.fgwilson.com The innovative and functional design of the 225 375 kva range enclosures ensures performance in the harshest of environments. Extremely durable

More information

Standby Rating 220/ / / / / /

Standby Rating 220/ / / / / / KDxxxx-YF designates a generator set with a fuel optimized engine. Ratings Range Standby: kw 2800 kva 3500 Prime: kw 2544 kva 3180 Standard Features D Kohler Co. provides one-source responsibility for

More information

Mobile Generator MMG25FHI Specifications

Mobile Generator MMG25FHI Specifications Mobile Generator MMG25FHI Specifications ENGINE Isuzu 4LE1NYGV-03 - naturally aspirated, diesel engine o Prime - 32 hp @ 1800 rpm o Standby - 35 hp @ 1800 rpm o 4 cylinder o 2.2 L displacement o Tier IV

More information

Magnum Mobile Generator MMG75 SS Specifications

Magnum Mobile Generator MMG75 SS Specifications Empowering Real People Magnum Mobile Generator MMG75 SS Specifications ENGINE John Deere PE4045TF285 - turbocharged, diesel engine o Prime - 91 hp @ 1800 rpm o Standby - 99 hp @ 1800 rpm o 4 cylinder o

More information

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00 This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

Standby Amper VOLTAGE

Standby Amper VOLTAGE INTRODUCTION Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and

More information

Mobile Generator MMG130 Specifications

Mobile Generator MMG130 Specifications Mobile Generator MMG130 Specifications ENGINE John Deere PE4045HFG93 - turbocharged, diesel engine o Prime - 152 hp @ 1800 rpm o Standby - 166 hp @ 1800 rpm o 4 cylinder o 4.5 L displacement o Interim

More information

Protector Series ISO FEATURES. Diesel Generator Set. Protector Series INCLUDES:

Protector Series ISO FEATURES. Diesel Generator Set. Protector Series INCLUDES: Protector Series Diesel Generator Set Protector Series 1 of 12 INCLUDES: Two Line LCD Multilingual Digital Evolution Controller (English/Spanish/French/ Portuguese) with external viewing window for easy

More information

Modular Acoustic Enclosures

Modular Acoustic Enclosures Modular Acoustic Enclosures 24 220 kva Range www.fgwilson.com The intelligent and striking design of the 24 220 kva enclosure range meets the demands of diverse applications. Extremely durable, the enclosures

More information

Magnum Mobile Generator MMG75 Specifications

Magnum Mobile Generator MMG75 Specifications Customer Driven Unsurpassed Value Magnum Mobile Generator MMG75 Specifications ENGINE John Deere PE4045TF285 - turbocharged, diesel engine o Prime - 91 hp @ 1800 rpm o Standby - 99 hp @ 1800 rpm o 4 cylinder

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE

More information

Magnum Mobile Generator MMG125 Specifications

Magnum Mobile Generator MMG125 Specifications Empowering Real People Magnum Mobile Generator MMG125 Specifications ENGINE John Deere PE6068TF275 - turbocharged, diesel engine o Prime - 150 hp @ 1800 rpm o Standby - 165 hp @ 1800 rpm o 6 cylinder o

More information

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00 cummins diesel 0 kva Phase Ratings, 0 Hz, PF 0,8 Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 00/0 0,00 88,00 00,00 80,00,00 Rating (ESP): Prime Rating (PRP): Applicable for supplying power

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency STANDBY POWER RATING 40 kw, 50 kva, 60 Hz PRIME POWER RATING* 36 kw, 45 kva, 60 Hz *Built in the USA using domestic and foreign parts *EPA Certified Prime ratings are not available in the U.S. or its Territories.

More information

Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 <Debut> 100KW GENERATOR

Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 <Debut> 100KW GENERATOR J100UC3 Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 100KW GENERATOR 100 KW / 125 KVA DIESEL GENERATOR SET, FULLY PACKAGED: JOHN DEERE Heavy duty diesel engine,

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

13,000 Watt Diesel Generator AGi13P E

13,000 Watt Diesel Generator AGi13P E GENERAL SPECIFICATIONS General Specifications Type Power Rating Standby Power Output Diesel Standby Generator 13,000 Watt (Standby) 12,000 Watt (Prime) 120 Volt @ 100 Amp 220 Volt @ 50 Amps Outputs 120

More information

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw SG/PG Series 35 kva 5.4L Industrial Spark-Ignited Generator Set Generac International Products 50 Hz Image used for illustration purposes only Rated Generators SG028 35 kva / 28 kw PG022 28 kva / 22 kw

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

Gree Genuine Accessories

Gree Genuine Accessories The GA Series Gree s PTAC Accessory Catalog Gree Genuine Accessories Offering a wide-range of quality accessories Electrical Wiring POWER CORD SELECTION: Power Cord: Model No. Voltage Receptacle Type The

More information

TERM OF USE Standard reference conditions ESP/PRP 27 C /40 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

TERM OF USE Standard reference conditions ESP/PRP 27 C /40 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity. V200U STANDARD FEATURES 200 KW / 250 KVA FULLY PACKAGED GENERATOR SET INCLUDES: VOLVO Heavy duty diesel engine, 4 stroke, 1800rpm, Turbo LEROY SOMER brushless alternator. IP23 protection, Insulation

More information

Climas y Proyectos Leyco, S.A. de C.V.

Climas y Proyectos Leyco, S.A. de C.V. GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA

More information

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating. SG/PG Series 200 kva 14.2L Industrial Spark-Ignited Generator Set Generac International Products Image used for illustration purposes only Power Ratings Standby SG160 200 kva / 160 kw Prime PG128 160 kva

More information

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00 This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information