1 ALN, AN and AGN Series: Non-Factory Sealed. -9 Applications Distribution panelboards are used to furnish protection and control of electrical equipment in hazardous locations. These compact units provide a centrally controlled switching system for large quantities of branch circuits for lighting, heating, small motors, and similar electrical equipment. Features Breaker operators included as standard. O-ring gasket insures watertight integrity. Stainless steel hinges are standard. Copper bus bars are standard. Quad-Lead stainless steel cover bolts are standard. ermits selection of 1,2 or 3 pole breakers. recision machined flame path between body and cover. Slotted mounting feet. Breaker operators can be padlocked in the On or Off position. All panelboards are supplied with Cutler-Hammer interiors. Chassis assembles with mains at top (bottom optional). For standard outlets, see outline dimensions. For custom outlets, consult factory. rovisions for 12, 18, 24, 30, 36 and 42 circuit single pole chassis. 100 Amp or 225A main lug. Up to 100 Amp backfed main breaker available with main lug chassis. Up to 225 Amp main breaker available with main breaker chassis. Factory installed ground and neutral bar as standard. Standard Materials Bodies and covers: Copper-free aluminum. Cover bolts: Quad-Lead stainless steel. Breaker Operators: copper-free aluminum. Hinges: stainless steel. O-Ring: Neoprene Standard Finishes Corrosion resistant grey epoxy powder coat to provide NEMA 4X rating. Compliances UL Standard 67,877,1203. CSA Certified - Standard C22.2, Nos 29,30. NEMA 4,4X,7BCD,9EFG Cutler-Hammer is a trademark of the Eaton Corporation. AGE 9
2 -10 Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 4,4X,7BCD,9EFG ALN Series Lighting Distribution anelboards: Non-Factory Sealed. SAMLE CAT. NO. A LN A12 A12 M1 BRANCH CIRCUITS (See footnote) MAIN TYE: M1 = 100A Frame M2 = 225A Frame ML = Main Lug Only NUMBER OF CIRCUITS: 12, 18, 24, 30, 36 & 42 WIRE SYSTEM: A = 1 3W C = 3 4W VOLTAGE: 1 = 120/240V 2 = 120/208V CURRENT RATING: 1 = 100A 2 = 225A ANEL SIZE: A = B = C = D = F = DUTY: Non-Factory Sealed Lighting anel ALETON Typical anelboard Wiring Diagram Single hase, 3-Wire Systems Three-hase, 4-Wire Systems MAIN 120/240V 120/208V Approx. No. of 1 hase 3 Wire 3 hase 4 Wire anel Weight Circuits BAB Type BAB Type Size (lbs) 12 ALNA11A12ML ALNA12C12ML A Amp 18 ALNB11A18ML ALNB12C18ML B 165 Main Lug Only 24 ALNC11A24ML ALNC12C24ML C ALNC11A30ML ALNC12C30ML C ALNC21A18ML ALNC22C18ML C ALNC21A24ML ALNC22C24ML C Amp 30 ALNC21A30ML ALNC22C30ML C 235 Main Lug Only 36 ALND21A36ML ALND22C36ML D ALND21A42ML ALND22C42ML D ALNC11A12M1 ALNC12C12M1 C 165 Main Breaker 18 ALNC11A18M1 ALNC12C18M1 C AF 24 ALND11A24M1 ALND12C24M1 D ALND11A30M1 ALND12C30M1 D 315 Factory Installed Options Description Suffix Breather, NEMA 4X, 7 & 9 BR Drain, NEMA 4X, 7 & 9 DN 5ma Ground Fault Interrupter GFI* 30ma Ground Fault Interrupter ED* GFI Indicating Light L5 henolic Nameplate N (Specify Legend) * GFI ush-to-test Buttons are standard with GFI or ED options. 18 ALNC21A18M2 ALNC22C18M2 C ALND21A24M2 ALND22C24M2 D 295 Main Breaker 30 ALND21A30M2 ALND22C30M2 D AF 36 ALND21A36M2 ALND22C36M2 D ALNF21A42M2 ALNF22C42M2 F 345 Note: For Back Fed main, replace ML, M1, or M2 in part number with BF. For 400A Main Lug, consult factory. Standard interrupting capacity is 10,000 AIC. For higher interrupt ratings, consult factory. Select branch breakers as desired in panel. First and second digits are the quantity of breakers, third and fourth digits are ampere rating, the fifth digit is number of poles. Example: An 18 circuit 120/240V 1 phase 3 wire 100A MLO panel with 12 single pole 20 amp and 3 two pole 30 amp branch breakers should read ALNB11A18ML AGE 10
3 Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 4,4X,7BCD,9EFG -11 AN Series ower Distribution anelboards: Non-Factory Sealed. SAMLE CAT. NO. A N A13 B12 M1 BRANCH CIRCUITS. (See footnote) MAIN TYE: M1 = 100A Frame M2 = 225A Frame ML = Main Lug Only NUMBER OF CIRCUITS: 12, 18, 24, 30, 36 & 42 WIRE SYSTEM: B = 3 3W C = 3 4W VOLTAGE: 3 = 480V 4 = 277/480V (3 4W Only) CURRENT RATING: 1 = 100A 2 = 225A ANEL SIZE: A = B = C = D = F = DUTY: N: Non-Factory Sealed ower anel ALETON Typical anelboard Wiring Diagram Three-hase, 4-Wire Systems 277/480V Approx. No. of 3 hase 4 Wire anel Weight Circuits GHB Type Size (lbs) 12 ANA14C12ML A Amp 18 ANB14C18ML B 165 Main Lug Only 24 ANC14C24ML C ANC14C30ML C ANC24C18ML C ANC24C24ML C Amp 30 ANC24C30ML C 235 Main Lug Only 36 AND24C36ML D AND24C42ML D ANC14C12M1 C 165 Main Breaker 18 ANC14C18M1 C AF 24 AND14C24M1 D AND14C30M1 D ANC24C18M2 C AND24C24M2 D 295 Main Breaker 30 AND24C30M2 D AF 36 AND24C36M2 D ANF24C42M2 F 345 Note: For Back Fed main, replace ML, M1, or M2 in part number with BF. For 400A Main Lug, consult factory. Standard interrupting capacity is 14,000 AIC. For higher interrupt ratings, consult factory. Select branch breakers as desired in panel. First and second digits are the quantity of breakers, third and fourth digits are ampere rating, the fifth digit is number of poles. Example: An 18 circuit 277/480V 1 phase 3 wire 100A MLO panel with 12 single pole 20 amp and 3 two pole 30 amp branch breakers should read ANB14C18ML Factory Installed Options Description Breather, NEMA 4X, 7 & 9 Drain, NEMA 4X, 7 & 9 henolic Nameplate (Specify Legend) Suffix BR DN N AGE 11
4 -12 Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 4,4X,7BCD,9EFG AN Series ower Distribution anelboards: Non-Factory Sealed. SAMLE CAT. NO. A N E13 B12 M1 BRANCH CIRCUITS (See footnote) MAIN TYE: M1 = 100A Frame M2 = 225A Frame ML = Main Lug Only NUMBER OF CIRCUITS: 12, 18, 24, 30, 36 & 42 WIRE SYSTEM: B = 3 3W C = 3 4W VOLTAGE: 3 = 480V 4 = 277/480V (3 4W Only) 6 = 600V CURRENT RATING: 1 = 100A 2 = 225A ANEL SIZE: E = G = H = DUTY: N: Non-Factory Sealed ower anel ALETON Typical anelboard Wiring Diagram Three hase, 3-Wire Systems Three-hase, 4-Wire Systems MAIN 480V 277/480V 600V Approx. No. of 3 hase 3 Wire 3 hase 4 Wire 3 hase 4 Wire anel Weight Circuits EHD Type EHD Type FDB Type Size (lbs) 12 ANE13B12ML ANE14C12ML ANE16C12ML E Amp 18 ANE13B18ML ANE14C18ML ANE16C18ML E 285 Main Lug 24 ANE13B24ML ANE14C24ML ANE16C24ML E 290 Only 30 ANG13B30ML ANG14C30ML ANG16C30ML G ANE23B18ML ANE24C18ML ANE26C18ML E Amp 24 ANG23B24ML ANG24C24ML ANG26C24ML G 390 Main Lug 30 ANG23B30ML ANG24C30ML ANG26C30ML G 395 Only 36 ANG23B36ML ANG24C36ML ANG26C36ML G ANH23B42ML ANH24C42ML ANH26C42ML H 545 Main 12 ANE13B12M1 ANE14C12M1 ANE16C12M1 E 285 Breaker 18 ANG13B18M1 ANG14C18M1 ANG16C18M1 G AF 24 ANG13B24M1 ANG14C24M1 ANG16C24M1 G ANG13B30M1 ANG14C30M1 ANG16C30M1 G ANG23B18M2 ANG24C18M2 ANG26C18M2 G 395 Main 24 ANG23B24M2 ANG24C24M2 ANG26C24M2 G 400 Breaker 30 ANH23B30M2 ANH24C30M2 ANH26C30M2 H AF 36 ANH23B36M2 ANH24C36M2 ANH26C36M2 H ANH23B42M2 ANH24C42M2 ANH26C42M2 H 560 Note: For Back Fed main, replace ML, M1, or M2 in part number with BF. For 400A Main Lug, consult factory. Standard interrupting capacity is 14,000 AIC. For higher interrupt ratings, consult factory. Select branch breakers as desired in panel. First and second digits are the quantity of breakers, third and fourth digits are ampere rating, the fifth digit is number of poles. Example: An 18 circuit 277/480V 3 phase 4 wire 100A MLO panel with 12 single pole 20 amp and 3 two pole 30 amp branch breakers should read ANE14C18ML Factory Installed Options Description Breather, NEMA 4X, 7 & 9 Drain, NEMA 4X, 7 & 9 henolic Nameplate (Specify Legend) Suffix BR DN N AGE 12
5 -13 ALN, AN Main Lug anelboard Dimensional Data and Mounting Hardware anel A anel B anel C Mounting anel Dimensions Standard Outlets Mounting Size A B C D E F1 F2 G H K Top Bottom Hdw. Set A (1) 2 (6) 1 AMH8 B (1) 2 (6) 1 AMH8 C (1) 3 (8) 1 AMH8 All dimensions are in inches. All outlets are NT. AGE 13
6 -14 ALN, AN Main Lug anelboard Dimensional Data and Mounting Hardware anel D anel E anel G anel H (Front View) (Front View) (Front View) (Front View) anel D (End View) anel E (End View) anel G (End View) anel H (End View) Mounting anel Dimensions Standard Outlets Mounting Size A B C D E F1 F2 G J H K Top Bottom Hdw. Set D (1) 3 (8) 1 AMH8 E (1) 3 (8) 1 AMH8 G (1) 3 (12) 1 AMH6 H (1) 3 (12) 1 AMH6 All dimensions are in inches. All outlets are NT. AGE 14
7 ALN, AN Main Breakers anelboard Dimensional Data and Mounting Hardware -15 anel C anel D anel E Mounting anel Dimensions Standard Outlets Mounting Size A B C D E F1 F2 G H K Top Bottom Hdw. Set C (1) 3 (8) 1 AMH8 D (1) 3 (8) 1 AMH8 E (1) 3 (8) 1 AMH8 All dimensions are in inches. All outlets are NT. AGE 15
8 -16 ALN, AN Main Breakers anelboard Dimensional Data and Mounting Hardware anel F anel G anel H (2) 1/2 NT FOR B/D Mounting anel Dimensions Standard Outlets Mounting Size A B C D E F1 F2 G J H K Top Bottom Hdw. Set F (1) 3 (12) 1 AMH8 G (1) 3 (12) 1 AMH6 H (1) 3 (12) 1 AMH6 All dimensions are in inches. All outlets are NT. AGE 16
9 Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 4,4X,7BCD,9EFG -17 AGN Series Ground Fault Interrupting Distribution anelboards: Non-Factory Sealed. SAMLE CAT. NO. A GN A ML BRANCH CIRCUITS (See footnote) MAIN TYE: ML = Main Lug Only NUMBER OF CIRCUITS: 4, 6, 12, 18, 24 WIRE SYSTEM: A = 1 3W C = 3 4W VOLTAGE: 1 = 120/240V 2 = 120/208V CURRENT RATING: 1 = 100A ANEL SIZE: AA = A = B = C = DUTY: GN: Non-Factory Sealed GFI anel ALETON Typical anelboard Wiring Diagram Single hase, 3-Wire Systems Three-hase, 4-Wire Systems Approx. No. of 120/240V 120/208V anel Weight Circuits 1 hase 3 Wire 3 hase 4 Wire Size (lbs) 4 AGNA11A04ML AGNA12C04ML AA Amp 6 AGNA11A06ML AGNA12C06ML AA 35 Main Lug Only 12 AGNA11A12ML AGNA12C12ML A AGNB11A18ML AGNB12C18ML B AGNC11A24ML AGNC12C24ML C 210 Note: For Back Fed main, replace last ML in part number with BF. For 100A Main Breaker, consult factory. Standard interrupting capacity is 10,000 AIC. For higher interrupt ratings, consult factory. Select branch breakers as desired in panel. First and second digits are the quantity of breakers, third and fourth digits are ampere rating, the fifth digit is number of poles. Example: An 18 circuit 120/240V 1 phase 3 wire 100A MLO panel with 12 single pole 20 amp 30 ma GFI and 3 two pole 30 amp 5 ma GFI branch breakers should read AGNB11A18ML-12201ED-03302GFI. Factory Installed Options Description Breather, NEMA 4X, 7 & 9 Drain, NEMA 4X, 7 & 9 5ma Ground Fault Interrupter 30ma Ground Fault Interrupter GFI Indicating Light henolic Nameplate (Specify Legend) * GFI ush-to-test Buttons are standard with GFI or ED options. Suffix BR DN GFI* ED* L5 N AGE 17
10 -18 AGN Series GFI anelboard Dimensional Data and Mounting Hardware anel AA anel A anel B anel C Mounting anel Dimensions Standard Outlets Mounting Size A B C D E F1 F2 G H K Top Bottom Hdw. Set AA (1) 1 (4) 3/4 AMH2 A (1) 2 (6) 1 AMH8 B (1) 2 (6) 1 AMH8 C (1) 3 (8) 1 AMH8 All dimensions are in inches. All outlets are NT. AGE 18
11 Class I, Div. 1 and 2 Groups B*,C*,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 4,4X,7BCD,9EFG -19 AF 480 Volt Factory Sealed ower Distribution anelboards: Applications Distribution panelboards are used to furnish protection and control of electrical equipment in hazardous locations. These compact units provide a centrally controlled switching system for large quantities of branch circuits for lighting, heating, small motors, and similar electrical equipment. Features Breaker operators included as standard. O-ring gasket insures watertight integrity. Stainless steel hinges are standard. Copper bus bars are standard. Quad-Lead stainless steel cover bolts are standard. Factory-sealed, no external seals are required for most branch circuits. All conduits must be sealed adjacent to enclosure for Class I, Div. 1, Groups B and C. Breakers are housed in the panel section and prewired to maximum circuit capacity, then wired to numbered terminals in the wiring compartment. Terminal compartment is interconnected to panel section with sealing hubs, unions and poured with sealing compound. ermits selection of 1, 2 or 3 pole breakers. recision machined flame path between body and cover. Bolt on stainless steel slotted mounting feet. Breaker operators can be padlocked in the On or Off position. All panelboards are supplied with Cutler-Hammer interiors. Chassis assembles with mains at top (bottom optional). rovisions for 12, 18, 24, 30, 36 and 42 circuit single pole chassis. 100 Amp or 225A main lug. Up to 100 Amp backfed main breaker available with main lug chassis. Up to 225 amp main breaker available with main breaker chassis. Factory installed ground and neutral bar as standard. Standard Materials Bodies and covers: copper-free aluminum. Cover bolts: Quad-Lead stainless steel. Breaker Operators: copper-free aluminum. Hinges: stainless steel. O-Ring: neoprene. Standard Finish: Corrosion resistant grey epoxy powder coat to provide NEMA 4X rating. Compliances UL Classified - Standard 67, 877, 1203 CSA Certified - Standard C22.2, Nos. 29, 30 NEMA 4,4X,7BCD,9EFG Cutler-Hammer is a trademark of the Eaton Corporation. *For Class I, Div. 1, Groups B and C, all conduits must be sealed adjacent to enclosure. AGE 19
12 -20 Class I, Div. 1 and 2 Groups B*,C*,D Class I, Zone 1 and 2 Groups IIA, IIB*+H2* Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 4,4X,7B*C*D,9EFG SAMLE CAT. NO. A F 13 B12 M1 AF 480, 600V Volt Factory Sealed ower Distribution anelboards: BRANCH CIRCUITS (See footnote) MAIN TYE: M1 = 100A Frame M2 = 225A Frame ML = Main Lug Only NUMBER OF CIRCUITS: 12, 18, 24, 30, 36 & 42 WIRE SYSTEM: B = 3 3W C = 3 4W VOLTAGE: 3 = 480V 4 = 277/480V (3 4W Only) 6 = 600V CURRENT RATING: 1 = 100A 2 = 225A ANEL SIZE: R S DUTY: F: Factory Sealed ower anel ALETON Typical anelboard Wiring Diagram Three hase, 3-Wire Systems Three-hase, 4-Wire Systems 480V 277/480V 600V No. of 3 hase 3 Wire 3 hase 4 Wire 3 hase 4 Wire Circuits EHD Type EHD Type FDB Type 12 AF13B12ML AF14C12ML AF16C12ML 100 Amp 18 AF13B18ML AF14C18ML AF16C18ML Main Lug 24 AF13B24ML AF14C24ML AF16C24ML Only 30 AFR13B30ML AFR14C30ML AFR16C30ML 18 AF23B18ML AF24C18ML AF26C18ML 225 Amp 24 AFR23B24ML AFR24C24ML AFR26C24ML Main Lug 30 AFR23B30ML AFR24C30ML AFR26C30ML Only 36 AFR23B36ML AFR24C36ML AFR26C36ML 42 AFS23B42ML AFS24C42ML AFS26C42ML Main 12 AF13B12M1 AF14C12M1 AF16C12M1 Breaker 18 AFR13B18M1 AFR14C18M1 AFR16C18M1 100AF 24 AFR13B24M1 AFR14C24M1 AFR16C24M1 30 AFR13B30M1 AFR14C30M1 AFR16C30M1 18 AFR23B18M2 AFR24C18M2 AFR26C18M2 Main 24 AFR23B24M2 AFR24C24M2 AFR26C24M2 Breaker 30 AFS23B30M2 AFS24C30M2 AFS26C30M2 225AF 36 AFS23B36M2 AFS24C36M2 AFS26C36M2 42 AFS23B42M2 AFS24C42M2 AFS26C42M2 Note: For Back Fed main, replace ML, M1, or M2 in part number with BF. For 400A Main Lug, consult factory. Standard interrupting capacity is 14,000 AIC. For higher interrupt ratings, consult factory. Select branch breakers as desired in panel. First and second digits are the quantity of breakers, third and fourth digits are ampere rating, the fifth digit is number of poles. Example: An 18 circuit 277/480V 3 phase 4 wire 100A MLO panel with 12 single pole 20 amp and 3 two pole 30 amp branch breakers should read AF14C18ML * For Class I, Div. 1, Groups B and C, all conduits must be sealed WITHIN 2 of enclosure. Factory Installed Options Description Breather, NEMA 4X Drain, NEMA 4X External Ground Stud Grounding Neutral Lug henolic Nameplate (Specify Legend) Suffix BR DN EGS GNL N AGE 20
ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight
ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationP-2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, IP66
-2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, I66 owerlex anelboards: Steel Enclosures Applications The owerlex anelboard provides indoor and
More informationDivision 1 Explosionproof Panelboards
Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationX1PB: Explosionproof Panelboards
X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel
More informationStandard Materials Bodies and covers: copper-free aluminum.
-26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and
More informationDISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are
More informationNEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS
More informationD2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal
More informationProduct Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33
SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More informationCIRCUIT BREAKER PANELBOARDS
CIRCUIT BREAKER PANELBOARDS Class l, ones 1 & 2, Groups llb+h 2 Certified File LR 11713 for B7L FEATURES-SPECIFICATIONS Applications Hazardous locations due to the presence of flammable gases or vapors,
More informationPlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationEXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable
More informationFACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive
More informationO-3. Compliances UL Classified UL 508, 698, 1203 NEMA 4, 4X, 7CD, 9EFG For CSA approvals, please consult factory.
Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. -3 Applications AE series threaded type combination
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:
More informationApplications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes
AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Class I, Division and, Groups C, D Class II, Division
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationPlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationDBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight
More informationPOWERPLEX PANELBOARD 1
1 POWERPLEX PANELBOARD 2 ADVANCING PANELBOARD TECHNOLOGY WITH COMPONENT LEVEL PROTECTION. Introducing the PowerPlex Panelboard. Appleton's PowerPlex Panelboard changes the face of hazardous location panelboards
More informationDry-Type Transformers Mini-Power Centers
Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant
More informationPlugs and Receptacles: Hazardous Location
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable
More informationNEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:
More informationStandard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors
More informationEBMC Combination Line Starters and Enclosures
EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,
More informationCircuit Breakers Hazardous
s Hazardous 3C Description Page No. Application/Selection 364 Auxiliary s & s EFD, EFDC Series 382 Thermal Magnetic s & s General Information and Dimensions EPC Series 370, 371 FLB Series 375 EBMB Series
More informationU-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof
U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationQuik-Spec Coordination Panelboard Specifications
Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationCIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES
CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationPanelboard Protection on a Global Scale
Panelboard Protection on a Global Scale Appleton Panelboards Brochure Selection guide. No matter what environment, location or power requirement, our panelboards have your facility covered. From a petrochemical
More informationPower distribution SynergEX panelboards. SynergEX. Class I, Division 2 panelboards
Power distribution SynergEX panelboards SynergEX Class I, Division 2 panelboards SynergEX panelboards for hazardous rated areas Maximum safety. Easy access, lower risk and less downtime. One of the biggest
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and
More informationEnclosures. Section E
Enclosures Section E Enclosures and junction boxes built and configured to meet the requirements of the most demanding hazardous areas and industrial environmental applications across the globe. E Enclosures
More informationSpring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationRCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel
RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals
Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents
More informationHazardous Factory Sealed Control Devices
Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationATX DPD Series Distribution Panelboards Flameproof
ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation
More informationEylander Electric Inc
Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL
More informationEnclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures
Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking
More informationLighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION
Lighting Panelboards EPLU and D2LU Series Installation & Maintenance Information APPLICATION EPLU and D2LU Series panelboards provide a centrally controlled switching system and short circuit protection
More information3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...
.6 Panelboards and Lighting Control PRC25 Panelboard PRC25 Panelboard Product The PRC25 panelboard is designed to meet the needs for control of lighting and small branch circuits. Used as a standalone
More informationHazardous Duty Applications
Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
DBR 30, 60, 100 and 150 Amp Series Receptacles Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals
Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal
DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)
More informationBulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches
2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationIndustrial Control & Circuit Breakers
Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide.
More informationExplosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC
9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB
More informationSynergEX Panelboards for Hazardous Locations
SynergEX Panelboards for Hazardous Locations Installation & Maintenance Information 1. APPLICATION SynergEX panelboards provide short circuit protection for feeder or branch circuits to control lighting,
More informationApplications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.
Contender Series Factory Sealed Front Operated Tumbler Switches Malleable Iron Body and Cover. Furnished with Internal Ground. NEMA 3, 7CD, 9EFG Applications Designed to prevent arcing of enclosed switches
More informationMotor Starters Hazardous and Non-Hazardous
Motor Starters Hazardous and Non-Hazardous Description Page No. Application/Selection 342 Magnetic Line Starters & Enclosures Single speed, non-reversing EBMS Series 343-346 EPC Series 349-351 EBMS Series
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center
Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"
More informationPanelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description
.5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,
More informationConduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.
-2 Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; UNILETS for use with Threaded Metal Conduit. Applications Meet a wide range of classified area requirements. Corrosion-resistant ideal indoors
More informationEOEM panelboard and switchboard (OPS) Program
Instructional Leaflet IL02009EN EOEM panelboard and switchboard (OPS) Program OPS Program overview The OPS Program enables EOEMs to purchase panelboard/switchboard chassis, boxes, trims, molded-case circuit
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits
More informationPLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE
PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE EASY TO INSTALL, OPERATE AND MAINTAIN. PlexPower Panelboards use circuit breaker modules that provide explosionproof protection for standard off-the-shelf
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationProduct Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle
L02-L12 01 Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. Applications Locations where receptacle is used with stationary or portable electrically operated devices such as lighting
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationFactory Sealed Panelboards
FACTORY SEALED PAELBOARDS Factory Sealed Designed for use In Class I, Division 2 and Class I, Zone 2 areas such as petroleum refineries, chemical or petrochemical facilities, the factory sealed panelboards
More informationDESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5
DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this
More informationCH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information
Manufacturer Description Weight per unit Product Category CH2AFIT 2P A Arc Fault Shared /Indpndt Trip BRKR Eaton Corp Features Current Rating AMPERE Interrupting Rating 10 KILOAMPERE Poles 2 Terminal Type
More informationJM - Junction Enclosure Modules for Communication Networks
Pub #110014revB, Part 1-12/2002 JM - Junction Enclosure Modules for Communication Networks Installation & Adjusting Instructions for JMT, JMP, JMS, JMD, JMB series The JM provides a watertight / explosion
More informationLaser Service Factory-assembled Panelboards
Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page
More informationEPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS
EPLX and D2LX lighting panelboards Installation & maintenance information APPLICATION EPLX and D2LX panelboards provide a centrally controlled switching system and short circuit protection for feeder or
More informationExplosionproof enclosures XPCJ series Cast aluminum steel control/junction box
1 TECHNICAL DATA SHEET Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box XPCJ series series of explosionproof aluminum enclosures are typically used in the packaging of electrical/electronic
More informationJunction Boxes Hazardous and Non-Hazardous
Junction Boxes Hazardous and Non-Hazardous Description Page No. Application/Selection 112 Boxes Flush EGJ Series 19 WJBF Recessed Sidewalk Cover Series 116 Service Station EGJ Series 19 GUA Series 17 GUP
More informationBulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers
Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)
804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit
More informationApplication guide. Tmax Link OEM UL 891 Switchboard Program
Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit
More information100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E
100-Ampere Busway Technical Data TD01701002E Effective November 2005 New Information Elbow, Busway and Cable Tap Box Contents General Information.............................. 2 Connections...............................
More informationGeneral Specifications for Lighthouse Power Pedestal
Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4
More informationCON EDISON EQUIPMENT
CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200
More informationBulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism
Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationTechnical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA
Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power
More informationCONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features
Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and
More informationCutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame
Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationPANELBOARDS C1/C2 SECTION 6
SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2
More informationLoadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application
Product Offering and Specificaton Guide Application Main lug loadcentre, b Phase 3 W /V, to 0A, / - 0/80 circuits b 3 Phase W /8V, 00 to 5A, - circuits Main Breaker loadcentre, b Phase 3 W /V, to 0A, /
More information