Hazardous Factory Sealed Control Devices

Size: px
Start display at page:

Download "Hazardous Factory Sealed Control Devices"

Transcription

1 Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot Light/Pushbutton Station Combinations EDS Series 46 Pushbutton Stations Front Operated EDS Series 4, 42 EFS Series 4 D2X Series 442, 44 Side Operated Rocker Handle EDS Series 44 Selector Switches Maintained Contact EDS Series 47 EFS Series 48 General Use Snap Switches EDS Series 49 US: CAN: Copyright 2006 Cooper Crouse-Hinds 427

2 EFS and EDS Factory Sealed Control Devices and Manual Motor Starting Switches Dimensions Pg. 40 Application: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled and are used: to prevent arcing of enclosed device from causing ignition of a specific hazardous atmosphere or atmospheres external to the enclosure in industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas, or metal handling or finishing areas where atmosphere may contain hazardous gases and/or dust in non-hazardous areas where sturdy, durable enclosures are required in conjunction with magnetic starters or contactors for remote control of motors Manual motor starting switch enclosures are used: for manual starting of small ac or dc motors to provide manual starting and stopping and, in the case of units with heaters, motor running protection Features: Factory sealed devices have many distinct advantages: reduce installation problems eliminate external seals lower installation costs improve safety are used with general purpose snap and pushbutton type switches standard neoprene covers for front operated pushbuttons. Prevents accumulation of dirt and entrance of water around operating shafts mounting lugs and taper tapped hubs with integral bushings large machine screws for fastening covers to bodies lockout provisions on front operated push button (marked STOP and OFF ) and selector switch covers lockout hole for padlock having hasp is provided when used with covers for front lever and side rocker type operation close tolerances in machining of wide, mating flanges and journalled shafts and bearings for front button operation, produces flametightness of enclosure joints on enclosures with front lever and side rocker type operating handles, threaded type shafts and bushings are used to ensure flametightness dead end (EFS or EDS) or through feed (EFSC or EDSC) hubs 2 to sizes Standard Materials: Bodies Feraloy iron alloy; copper-free aluminum. Front operated pushbutton and pilot light covers Feraloy iron alloy Side operated type pushbutton covers copper-free aluminum Shafts stainless steel Shaft bushings stainless steel Rocker handle and pushbutton guards type 6/6 nylon Sealing enclosures copper-free aluminum Standard Finishes: Feraloy iron alloy electrogalvanized and aluminum acrylic paint Copper-free aluminum natural Type 6/6 nylon black Stainless steel natural Options: The following special options are available from the factory by adding suffix to Cat. No. Certifications and Compliances: NEC/CEC: Class I, Division & 2, Groups B*,C,D Class II, Division, Groups E,F,G Class II, Division 2, Groups F,G Class III NEMA/EEMAC:,7B*CD,9EFG UL Standard: 894, 698 CSA Standard: C22.2 No. 0 Suffix to be Added to Description Cat. # Emergency Stop button (momentary) front operated red mushroom button...s Lockout provision on front operated pushbutton cover (standard on buttons marked OFF and STOP )...S5 For 24 VDC operation on pilot lights...s00 Three-position selector switches with modified operation: Momentary contact clockwise operation, spring return to center, maintained contact counter-clockwise operation...s64 Momentary contact counter-clockwise operation, spring return to center, maintained contact clockwise operation...s65 Bodies and covers (single and two gang units) copper-free aluminum...sa Where indicated in the catalog listings, EDS units suitable for Class I, Division, Group B usage can be supplied, add suffix - GB, EFS units are suitable for Class I, Division, Group B as standard...gb Maintained contact mushroom head with lockout and guard. Maximum one per cover and cannot be used with a pilot light with a transformer or another standard pushbutton... S769 EDS bodies and factory sealed cover and device sub-assemblies are available for field assembly (see pages 94 to 96). * See Options: suffix GB Suffix S US: CAN: Copyright 2006 Cooper Crouse-Hinds

3 EFS and EDS Factory Sealed Control Devices and Manual Motor Starting Switches Dimensions Pg. 40 Methods of Factory Sealing EFS/EDS Series EDS Series Factory sealed EDS and EFS pilot light, pushbutton and selector switch control stations do not need external sealing. Device contacts are factory sealed in explosionproof ESWP contact blocks. Small compact enclosures have accurately ground wide flanges on both the body and cover for a flame-tight joint. EDS factory sealed snap switches or manual motor starting switches do not need external sealing. The switches are enclosed in a unique sealing well with double flanges which mate with the cover and the body. Small compact enclosures have accurately ground wide flanges on body, cover and sealing well for flame-tight joints. Wiring pigtails are factory sealed from under the sealing well. Reliable pouring of seals at the factory ensures safe sealing. * Check listings for Group B suitability See Options page 428. US: CAN: Copyright 2006 Cooper Crouse-Hinds 429

4 EFS and EDS Factory Sealed Control Devices and Manual Motor Starting Switches Dimensions Dimensions (inches)** Bodies Side View Hub Dim. Dim. Size h i Front View Single gang Two gang Covers General use snap switch front operated and manual motor starting switch Push button switch rocker type side operated Push button switch front operated Selector switch ** Dimensions are approximate, not for construction purposes. * See listings. Surface covers have same length and width as bodies. 40 US: CAN: Copyright 2006 Cooper Crouse-Hinds

5 EDS Factory Sealed Pushbutton Stations Front Operated, 600VAC Heavy Duty, Dimensions Pg. 40 EDS284 EDS290 Normal Pos. Circuit 2 Circuits 2 Circuits** Marking Specify Specify START-STOP unless otherwise specified Pushbuttons ED ED2 ED2** Enclosure with Pushbuttons Hub Size Cat. # Cat. # Cat. # 2 EDS84 EDS5 EDS284 EDS290 EDS25 EDS84 EDS90 EDS5 Through Feed 2 EDSC84 EDSC90 EDSC5 EDSC284 EDSC290 EDSC25 EDSC84 EDSC90 EDSC5 Normal Pos. 2 Circuits 2 Circuits** Marking Specify Specify Pushbuttons ED2 ED2** Enclosure with Pushbuttons Hub Size Cat. # Cat. # 2 EDS55 EDS292 EDS255 EDS92 EDS55 Through Feed 2 EDSC92 EDSC55 EDSC292 EDSC255 EDSC92 EDSC55 * Class I, Group B: Consider using EFS series pushbuttons, see page 4. All enclosures listed above can be modified for Class I, Group B, Div. usage. Add suffix GB to the Cat. No. Seals must be installed within 2 of each conduit opening in Division. These products are suitable for Group B, Div. 2 as listed, without external seals. In Canada, for Group B applications consult factory. **Two universal contact blocks, must be wired as two circuits, with one normally open and one normally closed. Single external button operates both inner buttons simultaneously. Standard markings available are as follows: START OFF RESET LIGHT ON EMERGENCY OPEN DOWN RAISE STOP RUN TRIP HAND FORWARD CLOSE IN LOWER ON JOG TEST AUTOMATIC REVERSE UP OUT For replacement contact blocks, see page 400. US: CAN: Copyright 2006 Cooper Crouse-Hinds 4

6 EDS Factory Sealed Pushbutton Stations Front Operated, 600VAC Heavy Duty, Dimensions Pg. 40 EDSC225 Two Gang Normal Pos. Circuit 2 Circuits 2 Circuits** Marking Specify Specify START-STOP unless otherwise specified Pushbuttons ED ED2 ED2** Enclosure with Pushbuttons Hub Size Cat. # Cat. # Cat. # EDS2284 EDS2290 EDS225 EDS284 EDS290 EDS25 Through Feed 2 EDSC284 EDSC290 EDSC25 EDSC2284 EDSC2290 EDSC225 EDSC284 EDSC290 EDSC25 * Class I, Group B: Consider using EFS series pushbuttons, see page 4. All enclosures listed above can be modified for Class I, Group B, Div. usage. Add suffix GB to the Cat. No. Seals must be installed within 2 of each conduit opening in Division. These products are suitable for Group B, Div. 2 as listed, without external seals. In Canada, for Group B applications consult factory. **Two universal contact blocks, must be wired as two circuits, with one normally open and one normally closed. Single external button operates both inner buttons simultaneously. Standard markings available are as follows: START OFF RESET LIGHT ON EMERGENCY OPEN DOWN RAISE STOP RUN TRIP HAND FORWARD CLOSE IN LOWER ON JOG TEST AUTOMATIC REVERSE UP OUT For replacement contact blocks, see page US: CAN: Copyright 2006 Cooper Crouse-Hinds

7 EFS Factory Sealed Pushbutton Stations Front Operated, 600VAC Heavy Duty, Dimensions Pg. 40 EFS284 EFSC290 Normal Pos. Circuit 2 Circuits 2 Circuits** Normal Pos. 2 Circuits 2 Circuits** Marking Specify Specify START-STOP unless otherwise specified Pushbuttons ED ED2 ED2** Enclosure with Pushbuttons Hub Size Cat. # Cat. # Cat. # 2 EFS84 EFS5 EFS284 EFS290 EFS25 EFS84 EFS90 EFS5 Through Feed 2 EFSC84 EFSC90 EFSC5 EFSC284 EFSC290 EFSC25 EFSC84 EFSC90 EFSC5 Marking Specify Specify Pushbuttons ED2 ED2** Enclosure with Pushbuttons Hub Size Cat. # Cat. # 2 EFS55 EFS292 EFS255 EFS92 EFS55 Through Feed 2 EFSC92 EFSC55 EFSC292 EFSC255 EFSC92 EFSC55 * Class I, Group B: All enclosures listed above are suitable for Class I, Group B, Div. usage. Seals only have to be installed on inch conduit within 5 ft. in Division. **Two universal contact blocks, must be wired as two circuits, with one normally open and one normally closed. Single external button operates both inner buttons simultaneously. Standard markings available are as follows: START OFF RESET LIGHT ON EMERGENCY OPEN DOWN RAISE STOP RUN TRIP HAND FORWARD CLOSE IN LOWER ON JOG TEST AUTOMATIC REVERSE UP OUT For replacement contact blocks, see page 400. US: CAN: Copyright 2006 Cooper Crouse-Hinds 4

8 EDS Factory Sealed Push Button Stations Side Rocker Handle, 600VAC Heavy Duty, Dimensions Pg. 40 EDSC262 EDS2696 Normal Pos. Circuit 2 Circuits 2 Circuits** Two Gang Normal Pos. Circuit 2 Circuits 2 Circuits Marking Specify Specify START-STOP unless otherwise specified Marking Specify Specify START-STOP unless otherwise specified Push Buttons ED ED2 ED2** Enclosure with Push Buttons Hub Size Cat. # Cat. # Cat. # 2 EDS596 EDS62 EDS2596 EDS294 EDS262 EDS596 EDS94 EDS62 Through Feed 2 EDSC596 EDSC94 EDSC62 EDSC2596 EDSC294 EDSC262 EDSC596 EDSC94 EDSC62 Push Buttons ED ED2 ED2** Enclosure with Push Buttons Hub Size Cat. # Cat. # Cat. # EDS2696 EDS2294 EDS2262 EDS696 EDS294 EDS262 Through Feed 2 EDSC696 EDSC294 EDSC262 EDSC2696 EDSC2294 EDSC2262 EDSC696 EDSC294 EDSC262 * Class I, Group B: All enclosures listed above can be modified for Class I, Group B, Div. usage. Add suffix GB to the Cat. No. Seals must be installed within 2 of each conduit opening in Division. These products are suitable for Group B, Div. 2 as listed, without external seals. ** Two universal contact blocks, must be wired as two circuits, with one normally open and one normally closed. Standard markings available, heat stamped in nylon rocker handle, are as follows: START OFF RESET LIGHT ON EMERGENCY OPEN DOWN RAISE STOP RUN TRIP HAND FORWARD CLOSE IN LOWER ON JOG TEST AUTOMATIC REVERSE UP OUT For replacement contact blocks, see page US: CAN: Copyright 2006 Cooper Crouse-Hinds

9 EFS Factory Sealed Pilot Lights Dimensions Pg. 40 Cl. I, Div. & 2, Groups B,C,D NEMA,7BCD,9EFG Pilot lights listed below are factory sealed and do not require external seals. Lamps are 6 watt, type S6, candelabra base for use on 0-25 volt circuits. Enclosures with single pilot covers only can be equipped with a transformer for the lamp for higher voltages as shown. Pilot light covers with 2 pilot lights cannot be provided with transformer, as the transformer occupies the space of one pilot light. Transformer Voltages Above 25 Nominal Volts Primary Cat hertz Voltage No. Transformer Range Suffix 220/ T2 440/ T4 550/ T5 Class I, Group B: All enclosures listed above are suitable for Class I, Group B, Div. usage. Seals only have to be installed on inch conduit within 5 ft. in Division. These products are suitable for Group B, Div. 2 as listed, without external seals. EFS Enclosure with Single Pilot Light Hub Through Feed Size Cat. # Cat. # 2 EFS524- EFSC524- EFS2524- EFSC2524- EFS524- EFSC524- Enclosure with Two Pilot Lights 2 EFS56- EFSC56- EFS256- EFSC256- EFS56- EFSC56- Add color symbol for each pilot light from table below. Example: EFS56 with red and green lights is EFS56-J-J. Color Symbol Color Symbol Color Symbol Red J Amber J6 Blue J Green J Clear J0 LED pilot lights can be furnished in place of standard incandescent pilot lamps. Add suffix LED to catalog number after color symbol. For 24 VDC operation, add suffix S00. US: CAN: Copyright 2006 Cooper Crouse-Hinds 45

10 EDS Factory Sealed Combination Pushbutton and Pilot Light Stations 600VAC Heavy Duty, Dimensions Pg. 40 Pushbutton contacts and pilot light receptacles are sealed in separate chambers. External seals are not required. Lamps are 6 watt, type S6, candelabra base for use on 0-25 volt circuits. Two gang units with single pilot light covers can be furnished with transformers. See page 45 for details and suffixes. Specify markings for each button. See table below listings. No. Pushbuttons No. Pilot Lights Hub Size Cat. # Through Feed Cat. # 2 EDS47- EDSC47- EDS247- EDSC247- EDS47- EDSC47- Two Gang No. Pushbuttons No. Pilot Lights 2 2 Dead Through Dead Through End Feed End Feed Hub Size Cat. # Cat. # Cat. # Cat. # 2 EDS247- EDSC247- EDS2247- EDSC2247- EDS EDSC EDS247- EDSC247- EDS2868- EDSC2868- Add color symbol for each pilot light from table on page 45. Example: EDS247 with a red light is EDS247-J. LED pilot lights can be furnished in place of standard incandescent pilot lamps. Add suffix LED to catalog number after color symbol. For 24 VDC operation on pilot lights add suffix S00. Standard markings available are as follows: START OFF RESET LIGHT ON EMERGENCY OPEN DOWN RAISE STOP RUN TRIP HAND FORWARD CLOSE IN LOWER ON JOG TEST AUTOMATIC REVERSE UP * All enclosures listed above can be modified for Class I, Group B, Division usage. Add suffix GB to the Cat. No. Example: EDS47-J-GB. Conduit seal(s) must be installed within 2 of each conduit opening. These products are suitable for Group B, Div. 2 as listed, without external conduit seals. OUT 46 US: CAN: Copyright 2006 Cooper Crouse-Hinds

11 EDS Factory Sealed Selector Switches Maintained Contact, 600VAC Heavy Duty, Dimensions Pg. 40 Furnished with pushbuttons, cam actuated by a maintained contact selector mechanism to operate in the sequences shown in the diagrams below. Specify indicating plate markings. See table below listings. EDS27 EDS27 Enclosure With Switch Position Position Position contact Hub Through Feed Style 2 blocks Size Cat. # Cat. # Two- Position, Two- Circuit ED 2 EDS27 EDS227 EDS27 EDSC27 EDSC227 EDSC27 Two- Position, Four- Circuit ED2 2 EDS272 EDS2272 EDS272 EDSC272 EDSC2272 EDSC272 Three- Position, Two- Circuit ED 2 EDS27 EDS227 EDS27 EDSC27 EDSC227 EDSC27 Three- Position, Four- Circuit ED2 ED2 2 2 EDS274 EDS2274 EDS274 EDS275 EDS2275 EDS275 EDSC274 EDSC2274 EDSC274 EDSC275 EDSC2275 EDSC275 * For Class I, Group B: Consider using EFS series selector switches, see page 420. All enclosures listed above can be modified for Class I, Group B, Div. usage. Add suffix GB to the Cat. No. Seals must be installed within 2 of each conduit opening in Division. These products are suitable for Group B, Div. 2 as listed, without external seals. In Canada, for Group B applications consult factory. For replacement contact blocks, see page 400. Standard indicating plate markings available are as follows: Two-Position RUN, JOG FAST, SLOW IN, OUT HAND, AUTOMATIC OPEN, CLOSE RAISE, LOWER FORWARD, REVERSE UP, DOWN START, STOP ON, OFF Three-Position RUN, OFF, JOG, OFF, 2 HAND, OFF, AUTOMATIC OPEN, OFF, CLOSE FORWARD, OFF, REVERSE UP, OFF, DOWN FAST, OFF, SLOW US: CAN: Copyright 2006 Cooper Crouse-Hinds 47

12 EFS Factory Sealed Selector Switches Maintained Contact, 600VAC Heavy Duty, Dimensions Pg. 40 Furnished with pushbuttons, cam actuated by a maintained contact selector mechanism to operate in the sequences shown in the diagrams below. Specify indicating plate markings. See table below listings. EFS27 EFS27 Enclosure With Switch Position Position Position Contact Hub Through Feed Style 2 Blocks Size Cat. # Cat. # Two- Position, Two- Circuit ED 2 EFS27 EFS227 EFS27 EFSC27 EFSC227 EFSC27 Two- Position, Four- Circuit ED2 2 EFS272 EFS2272 EFS272 EFSC272 EFSC2272 EFSC272 Three- Position, Two- Circuit ED 2 EFS27 EFS227 EFS27 EFSC27 EFSC227 EFSC27 Three- Position, Four- Circuit ED2 ED2 2 EFS274 EFS2274 EFS274 EFSC274 EFSC2274 EFSC274 2 EFS275 EFS2275 EFS275 EFSC275 EFSC2275 EFSC275 * Class I, Group B: All enclosures listed above are suitable for Class I, Group B, Div. usage. Seals only have to be installed on inch conduit within 5 ft. in Division. For replacement contact blocks see page 400. Standard indicating plate markings available are as follows: Two-Position RUN, JOG FAST, SLOW IN, OUT HAND, AUTOMATIC OPEN, CLOSE RAISE, LOWER FORWARD, REVERSE UP, DOWN START, STOP ON, OFF Three-Position RUN, OFF, JOG, OFF, 2 HAND, OFF, AUTOMATIC OPEN, OFF, CLOSE FORWARD, OFF, REVERSE UP, OFF, DOWN FAST, OFF, SLOW 48 US: CAN: Copyright 2006 Cooper Crouse-Hinds

13 EDS Factory Sealed General Use Snap Switches Dimensions Pg. 40 EDSC229 EDS2229 General Use Snap Switch Front Operated Hub Amperes Size Style 20VAC 277VAC Cat. # Through Feed Cat. # Two Gang Cat. # Through Feed Cat. # -pole EDS229 EDSC229 EDS2229 EDSC pole EDS28 EDSC28 EDSC228 -way EDS20 EDSC20 EDS220 EDSC220 4-way EDS240 EDSC240 EDSC2240 -pole EDS29 EDSC29 EDS229 EDSC229 2-pole EDS8 EDSC8 EDS28 EDSC28 -way EDS0 EDSC0 EDS20 EDSC20 4-way EDS40 EDSC40 EDS240 EDSC240 ON-OFF standard marking for -pole and 2-pole units. Combinations of switches can be furnished. AC rated switches are tested for resistive, inductive and tungsten filament loads up to the full current rating and for motor loads up to 80% of the ampere rating. * Class I, Group B: All units on this page can be modified for Class I, Group B usage. Add suffix GB to the Cat. No. Seals must be installed within 2 of each conduit opening in Division. In Canada, for Group B applications consult factory. US: CAN: Copyright 2006 Cooper Crouse-Hinds 49

14 EDS Factory Sealed Manual Motor Starting Switches and Enclosures Dimensions Pg. 40 EDSC299 EDS2299 With Allen-Bradley Bulletin 600 Switches Maximum HP Ratings Allen-Bradley Switch Poles Volts AC Volts DC Cat. # hp A B BUL 600 T0X4 2 hp hp A B BUL 600 T0X5 Dead Through Hub End Feed Poles Size Cat. # Cat. # EDS299 EDSC299 EDS99 EDSC99 2 EDS200 EDSC200 EDS00 EDSC00 Two Gang EDS2299 EDSC2299 EDS299 EDSC299 2 EDS2200 EDSC2200 EDS200 EDSC200 Heater Table (Allen Bradley) Max. Motor Full-Load Amps Crouse- Hinds Symbol Number Max. Motor Full-Load Amps Crouse- Hinds Symbol Number 0.7 P 2.40 P P P P 2.92 P P4.09 P2 0.9 P5.2 P P6.77 P P7 4.6 P P8 4.5 P P9 4.9 P P0 5.4 P P 6.0 P0.08 P2 6.8 P.9 P 7.72 P2.0 P P.4 P P4.58 P P5.75 P P6.88 P P7 2. P9.50 P P9 These heaters are for motors rated 40 C continuously. For motors rated 50 C or 55 C, multiply full load motor current by 0.9 and use this value to select heaters. Symbol 0 (zero) must be used to indicate heater omitted. * Class I, Group B: All units on this page can be modified for Class I, Group B usage. Add suffix GB to the Cat. No. Seals must be installed within 2 of each conduit opening in Division. In Canada, for Group B applications consult factory. See page 44 for enclosures with General Electric and Cutler-Hammer switches. Includes one interchangeable heater. Select from the heater table and use symbol number as second section of the Cat. No. Example: EDS299-P5. Insert symbol 0 (zero) to omit heater. 440 US: CAN: Copyright 2006 Cooper Crouse-Hinds

15 EDS Factory Sealed Manual Motor Starting Switches and Enclosures Dimensions Pg. 40 With General Electric Switches Maximum HP Ratings G.E. Switch Poles Volts AC Volts DC Volts DC Cat. # hp hp hp CR0-Y 2 hp hp hp CR0-H Dead Through Hub End Feed Poles Size Cat. # Cat. # EDS209 EDSC209 EDS09 EDSC09 2 EDS2094 EDSC2094 EDS094 EDSC094 Two Gang EDS2209 EDSC2209 EDS209 EDSC209 2 EDS22094 EDSC22094 EDS2094 EDSC2094 With Cutler-Hammer Switches Maximum HP Ratings Cutler- Hammer Switch Poles Volts AC Volts DC Volts DC Volts DC Cat. # hp hp hp MST0 2 hp hp hp hp MST02 Dead Through Hub End Feed Poles Size Cat. # Cat. # EDS20 EDSC20 EDS0 EDSC0 2 EDS202 EDSC202 EDS02 EDSC02 Two Gang EDS220 EDSC220 EDS20 EDSC20 2 EDS2202 EDSC2202 EDS202 EDSC202 These heaters are for motors rated 40 C continuously. For motors rated 50 C or 55 C, multiply full load motor current by 0.9 and use this value to select heaters. Symbol 0 (zero) must be used to indicate heater omitted. Heater Table (General Electric) Max. Motor Full-Load Amps Crouse- Hinds Symbol Number Max. Motor Full-Load Amps Crouse- Hinds Symbol Number.0 G22.48 G2.27 G2.5 G.56 G24.58 G4.88 G25.65 G G26.7 G G27.78 G G28.86 G8 5.4 G29.95 G G0.04 G0 6.4 G.4 G 6.98 G2.25 G G.7 G 8.25 G4.49 G G5.6 G G6.78 G G7.95 G7.40 G8 2. G G9 2.2 G9.60 G G G G G42 Heater Table (Cutler-Hammer) Max. Motor Full-Load Amps Crouse- Hinds Symbol Number Max. Motor Full-Load Amps Crouse- Hinds Symbol Number.4 W 2.95 W2.48 W2.27 W22.5 W.59 W2.58 W4.99 W24.64 W5 4.9 W25.7 W W26.78 W W27.87 W8 5.8 W28.95 W9 6.9 W29.0 W0 7.0 W0.5 W 7.74 W.27 W W2.5 W 9.5 W.5 W4 0.0 W4.67 W5.5 W5.8 W W6.99 W7.67 W7 2.2 W8 5.2 W W W9 2.7 W20 Includes one interchangeable heater. Select heater from the table below individual listings and use symbol number as second section of the Cat. No. Example: EDS20-W5. Insert symbol 0 (zero) to omit heater. * Class I, Group B: All units on this page can be modified for Class I, Group B usage. Add suffix GB to the Cat. No. Seals must be installed within 2 of each conduit opening in Division. In Canada, for Group B applications consult factory. US: CAN: Copyright 2006 Cooper Crouse-Hinds 44

16 D2X Series FLEXITITE TM Attachable Pendant Pushbutton Stations for Class I, Div. 2 Areas Factory Sealed NEMA,4X,5,6,7BCD(Div. 2),9FG(Div. 2),2 Watertight Dust-tight Application: FLEXITITE attachable pendant pushbutton stations are used: for safe multi-function motor circuit control of: Hoists Cranes Machine Tools Electromagnets in hazardous areas such as Class I, Division 2, Groups B, C and D (classified) areas or Class II, Division 2, Groups F and G, as defined by the National Electrical Code where wash downs are necessary in damp, wet, dirty or corrosive locations for control applications requiring 2 to 8 functions Features: Safety cushioned neoprene encapsulations protects internal switches and connectors from impact damage and provides extra protection for personnel. Stress relief for your cable is built-in. A separate cable grip is not needed. Uses Cooper Crouse-Hinds ESWP factory sealed contacts suitable for use in Class I, Division 2, Groups B, C and D Switches are rated for 0 amps 600 VAC (NEMA A600). Indicator plates meet OSHA requirements for clear identification of functions. A full set of plates is included with each station. Jam resistant operator buttons are raised flexible diaphragms an integral part of the molded one-piece cover. Compact design Safety yellow finish. Standard Materials: Body and Cover steel reinforced neoprene Strain relief and reinforcement plates stainless steel Exterior hardware stainless steel Standard Finishes: Neoprene safety yellow Stainless steel natural Certifications and Compliances: NEMA:,4X,5,6,7BCD(Div. 2),9FG (Div. 2),2 UL Standard: 508 CSA Standard C22.2 No.4 8-Button Control Station 442 US: CAN: Copyright 2006 Cooper Crouse-Hinds

17 D2X FLEXITITE TM Attachable Pendant Pushbutton Stations for Class I, Div. 2 Areas Factory Sealed NEMA,4X,5,6,7BCD(Div. 2),9FG(Div. 2),2 Watertight Dust-Tight Ordering Information Control Stations Description Cable Dia. Catalog # 2-Button..75 D2X Button D2X Button.59.8 D2X Button D2X Indicator Plates (A full set is included with each control station) 2-Button Part No. Description Part No. Description 56- Down/West 56-7 Rev/Left 56-2 Start/North 56-8 Up/East 56- Stop/South 56-4 Off/In 56-5 On/Out 56-6 Fwd/Right 4, 6 and 8-Button Part No. Description Part No. Description Bridge Fwd/Rev Trolley North/South Hoist On/Off In/Out Start/Stop Up/Down Right/Left East/West Switch Part No. ESWP26 Dimensions (inches) 2-Button 4-Button 6-Button 8-Button US: CAN: Copyright 2006 Cooper Crouse-Hinds 44

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA) 804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed

More information

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles ENR Value Series Dead Front Interlocked Circuit Breaking s Cl. I, Div. & 2, roups B, C, D Cl. II, Div. & 2, roups F, Cl. III, 7BCD, 9F, 2 Dust-Ignitionproof Raintight et Locations ENP Plugs Applications:

More information

Control Stations Hazardous and Non-Hazardous

Control Stations Hazardous and Non-Hazardous Control Stations Hazardous and Non-Hazardous Description Page No. Application/Selection 384, 385 Controls for Bulk Solids Handling AFA/AFAX Conveyor Alignment Switches 417 AFU/AFUX Conveyor Control Safety

More information

Motor Starters Hazardous and Non-Hazardous

Motor Starters Hazardous and Non-Hazardous Motor Starters Hazardous and Non-Hazardous Description Page No. Application/Selection 342 Magnetic Line Starters & Enclosures Single speed, non-reversing EBMS Series 343-346 EPC Series 349-351 EBMS Series

More information

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed Arktite Circuit Breaking CPS Application: CPS receptacles, angle and straight types, and CPP plugs are used: with portable electrically operated devices such as motor-generator sets, compressors, conveyors,

More information

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw. Contender Series Factory Sealed Control Stations and Pilot Lights Furnished with Internal Ground Screw. Applications Push buttons and selector switches are used in conjunction with contactors or magnetic

More information

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +

More information

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes WP Plugs and DS Receptacles For FS and FD Cast Device Boxes Weatherproof 3F Application: WP plugs and DS receptacles are used: wherever dust, dirt, moisture and corrosion are a problem outdoors or in locations

More information

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Description Page No. Application/Selection 1000, 1001 Arktite Delayed Action Circuit Breaking Technical Data 1002, 1003 20 & 30A CPS Receptacle

More information

Covers for Cast Iron or Aluminum Device Boxes

Covers for Cast Iron or Aluminum Device Boxes Single Gang Blank cover for enclosing splices and taps where device not used. Sheet DS100 Flush Sheet steel DSS100 For GFI receptacles. Sheet steel DS23 GFI For square handle general use snap or toggle

More information

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications

More information

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models. Contender Series Factory Sealed Front Operated Tumbler Switches Malleable Iron Body and Cover. Furnished with Internal Ground. NEMA 3, 7CD, 9EFG Applications Designed to prevent arcing of enclosed switches

More information

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Description Page No. Application/Selection see pages 1260 1261 Arktite Delayed Action Circuit Breaking Technical Data see pages 1262 126 20

More information

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and

More information

Spring-loaded cover seats against neoprene gasket.

Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs

More information

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:

More information

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit. UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and disconnect

More information

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors

More information

EBMC Combination Line Starters and Enclosures

EBMC Combination Line Starters and Enclosures EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,

More information

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect

More information

Plugs and Receptacles: Hazardous Location

Plugs and Receptacles: Hazardous Location U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable

More information

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit. EDS Factory Sealed Tumbler Switches UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D NEMA 7 B CD, 9EFG Applications Designed to prevent arcing of enclosed switches

More information

Circuit Breakers Hazardous

Circuit Breakers Hazardous s Hazardous 3C Description Page No. Application/Selection 364 Auxiliary s & s EFD, EFDC Series 382 Thermal Magnetic s & s General Information and Dimensions EPC Series 370, 371 FLB Series 375 EBMB Series

More information

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Controls CONTROLS: HAZARDOUS LOCATION CONTROL STATIONS AND SWITCHES

More information

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class

More information

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle L02-L12 01 Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. Applications Locations where receptacle is used with stationary or portable electrically operated devices such as lighting

More information

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Connectors Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.

More information

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:

More information

Division 2 Contender Series Factory Sealed Control Stations

Division 2 Contender Series Factory Sealed Control Stations NEMA 3, 3R, 4, 4X, 12 IP66 Applications For use in washdown areas and other damp, wet and highly corrosive areas. Push buttons and selector switches are used in conjunction with contactors or magnetic

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

Push Button. Rocker Arm

Push Button. Rocker Arm -26 Class I, Div. 1 and 2 Class I, Div. 2 Group B NEA 3,7CD,9EFG Contender Series Factory Sealed Control Stations and Pilot Lights: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION DBR 30, 60, 100 and 150 Amp Series Receptacles Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations

More information

Condulet Conduit Bodies and Outlet Boxes Hazardous

Condulet Conduit Bodies and Outlet Boxes Hazardous Condulet Conduit Bodies and Outlet Boxes Hazardous 4F Description Page No. Application/Selection 48, 49 Lubricants HTL 59 STL 59 Conduit Bodies & Outlet Boxes Cylindrical EKC 57 90 Elbow LBH 58 LBY 58

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

Junction Boxes Hazardous and Non-Hazardous

Junction Boxes Hazardous and Non-Hazardous Junction Boxes Hazardous and Non-Hazardous Description Page No. Application/Selection 112 Boxes Flush EGJ Series 19 WJBF Recessed Sidewalk Cover Series 116 Service Station EGJ Series 19 GUA Series 17 GUP

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas 1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated

More information

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION Lighting Panelboards EPLU and D2LU Series Installation & Maintenance Information APPLICATION EPLU and D2LU Series panelboards provide a centrally controlled switching system and short circuit protection

More information

Industrial Control & Circuit Breakers

Industrial Control & Circuit Breakers Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide.

More information

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic

More information

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly Part #: EPO-25A The Larson Electronics EPO-25A explosion proof power outlet provides a durable and secure weatherproof power connection

More information

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking

More information

Condulet Cast Device Boxes and Covers Application and Selection

Condulet Cast Device Boxes and Covers Application and Selection F Condulet Cast and Covers Application and Selection Application: Cast device boxes are installed in conduit and cable systems to: Accommodate wiring devices Act as pull boxes for conductors in a conduit

More information

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections

More information

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC 9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB

More information

Hazardous Duty Applications

Hazardous Duty Applications Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks

More information

GHG43 Series Control Stations

GHG43 Series Control Stations GHG43 Series Control Stations Nonmetallic or 316L Stainless Steel UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, (A) Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cul) PTB ATEX

More information

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous 3P Description Page No. Application/Selection 1016, 1017 Interlocked Receptacle with Disconnect Switch WSR 30, 60, 100A Aluminum 1018,

More information

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. : Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

T38 1 T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T38 1" T Form 7 Malleable Iron Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit

More information

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) 4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are

More information

IEC 309 Plugs, Connectors, Receptacles, and Inlets

IEC 309 Plugs, Connectors, Receptacles, and Inlets IEC 309 Plugs, Connectors, Receptacles, and Inlets Applications: Where complete protection against dirt, dust, and water jets is required In damp or corrosive locations In areas prone to vibration, hard

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS SECTION 16420 ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles P Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33 SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ARL2042 Receptacle Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

3.1. NEMA Manual Starters.   Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters... Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp

More information

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL 13686.00 MECHANICAL AND ELECTRICAL COORDINATION 230002-1 SECTION 230002 MECHANICAL AND ELECTRICAL COORDINATION 1.1 WORK INCLUDED PART 1 - GENERAL A. Work Included in This Section: Materials, equipment,

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

Enclosures. Section E

Enclosures. Section E Enclosures Section E Enclosures and junction boxes built and configured to meet the requirements of the most demanding hazardous areas and industrial environmental applications across the globe. E Enclosures

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked

More information

FACTORY SEALED CONTROLS - INTRODUCTION

FACTORY SEALED CONTROLS - INTRODUCTION FACTORY SEALED - INTRODUCTION Contact Factory for other certification details D2CU Factory Sealed Contact Block Applications Seal-XM Factory Sealed push button stations, selector switches, pilot lights

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Class I, Division and, Groups C, D Class II, Division

More information

UniCode Series Factory Sealed Control Stations and Pilot Lights

UniCode Series Factory Sealed Control Stations and Pilot Lights Applications For use in hazardous areas as defined by the National Electrical Code (NEC), and Canadian Electrical Code (CEC). For use in washdown areas and other damp, wet and highly corrosive areas. Push

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number ACP1034CD Manufacturer Appleton/Oz Gedney

More information

Standard Materials Bodies and covers: copper-free aluminum.

Standard Materials Bodies and covers: copper-free aluminum. -26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and

More information

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS EPLX and D2LX lighting panelboards Installation & maintenance information APPLICATION EPLX and D2LX panelboards provide a centrally controlled switching system and short circuit protection for feeder or

More information

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit Condulet Single Gang Cast Accessories Pages to 44 F Application: Cast device boxes are installed to: accommodate wiring devices act as pull boxes for conductors in a conduit system provide openings to

More information

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections

More information

SECTION MOTORS & MOTOR CONTROLLERS

SECTION MOTORS & MOTOR CONTROLLERS SECTION 15170 MOTORS & MOTOR CONTROLLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Electric motors. B. Motor controllers for Packaged equipment. 1.02 SUBMITTALS A. Wiring diagrams with electrical characteristics

More information

PEERLESS BLOWERS DIRECT DRIVE BLOWERS

PEERLESS BLOWERS DIRECT DRIVE BLOWERS PEERLESS BLOWERS DIRECT DRIVE BLOWERS PEERLESS BLOWERS DIRECT DRIVE BLOWERS APPLICATION: Used extensively for general ventilation of small areas where duct systems are required. Used for washrooms, restaurants

More information