1 -26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and Non-Combination motor starters are used in areas where hazardous materials are handled or stored. These units provide disconnecting means, under voltage protection, circuit protection, and motor running protection. Features 65,000 AIC. Highest interrupt rated enclosure in the industry. Copper-free cast aluminum. Precision machined flame path between box and cover. Bolt on slotted mounting feet. Stainless steel block hinges. Stainless steel, captive Quad-Lead cover bolts (disengaged in 1-1/2 turns). External stainless steel breaker operating handle. Breaker and operator shafts are stainless steel. Ground lug package and installation instructions for termination of ground wire enclosed. Four point control terminal block, NEMA 1B w/wire markers. Breaker operators can be locked in the n or ff position (combination starters only). Four plugged 3/4 NPSM outlets drilled and tapped for control devices. Standard outlets top and bottom. Plugged 1/2 outlets top and bottom for breather/drain. Components are mounted on a galvanized steel removable pan. Enclosures are designed to accept Cutler-Hammer, or Square D motor starters/circuit breakers. For other manufacturers, consult factory. -ring Gasket insures watertight integrity. Standard Materials Bodies and covers: copper-free aluminum. Cover bolts: stainless steel -ring: neoprene Hinges: stainless steel. Standard Finish Corrosion resistant grey powder coat epoxy inside & out. ptions See page -46. Compliances: UL Standard 50, 698, 877, CSA Certified - Standard C22.2 No 30. NEMA 4, 4X, 7BCD, 9EFG. Cutler Hammer is a trademark of the Eaton Corporation. Square D is a trademark of Groupe Schneider. PAGE 26
2 AEB Series: Catalog Numbering Logic -27 SAMPLE CATALG NUMBER Example: The part number below depicts an Appleton, Class I, Div. I, Groups B,C & D, NEMA Size 1, Bolted type, Combination Full Voltage Non-Reversing Motor Starter operating at 480VAC, Cutler-Hammer starter w/120vac control voltage, and a Cutler-Hammer 7A MCP. If a breaker is not required, omit last two characters. AE 1 B B 4 W 1 C 2 * Suffix for ther ptions/features (See Modifications on Page -46) Breaker Trip (MCP) 1=3A 4=30A 7=100A 0=400A 2=7A 5=50A 8=150A 3=15A 6=70A 9=250A Breaker Trip (Thermal Mag) A=15A F=40A M=90A S=200A X=400A B=20A G=50A N=100A T=225A C=25A H=60A P=125A U=250A D=30A J=70A Q=150A V=300A E=35A K=80A R=175A W=350A Breaker Manufacturer C=Cutler-Hammer S=Square D (Consult factory for other manufacturers) Control Voltage (120V coil standard) (1) 1=120V 4=480V 7=24VDC 2=240V 5=575V 8=48VDC 3=380V 6=600V Starter Manufacturer W=Cutler-Hammer (A200) S=Square D (8536) (Consult factory for other manufacturers) perating Voltage 1=120V 4=480V 7=24VDC 2=240V 5=575V 8=48VDC 3=380V 6=600V Starter Function A=FVNR (ATL) G=2S2W B=Comb. FVNR H=Comb. 2S2W C=FVR J=Contactor (3 pole) D=Comb. FVR K=Comb. Contactor (3 pole) E=2S1W M=Lighting Contactor (3-12 pole) F=Comb. 2S1W N=Comb. Lighting Contactor (3-12 pole) (Consult factory for enclosure layouts on starter functions C, D, E, F, G & H) Enclosure Type B Series NEMA Size (0, 1, 2, 3, 4 & 5) (For Size 6 consult factory) Series AE (1) 120V power must be provided from separate source, or by adding CPT option. Cutler Hammer is a trademark of the Eaton Corporation. Square D is a trademark of Groupe Schneider. PAGE 27
3 -28 Class I, Div. 1 and 2 AEB Series Motor Starter Enclosures: Non-Reversing Bolted Enclosure. Combination Full Voltage Non-Reversing Enclosure nly NEMA Catalog Approx. Standard Mtg. Hdw. Size Number Weight (lbs) Conduit Set Cat. No. 0 AE0BB /2 AMH7 1 AE1BB /2 AMH7 2 AE2BB /2 AMH7 3 AE3BB /2 AMH7 4 AE4BB /2 AMH7 5 AE5BB AMH8 Full Voltage Non-Reversing Enclosure nly NEMA Catalog Approx. Standard Mtg. Hdw. Size Number Weight (lbs) Conduit Set Cat. No. 0 AE0BA /2 AMH7 1 AE1BA /2 AMH7 2 AE2BA /2 AMH7 3 AE3BA AMH7 4 AE4BA /2 AMH7 5 AE5BA AMH8 PAGE 28
4 Class I, Div. 1 and 2-29 AEB Series Full Voltage Motor Starters: 3 Phase, 60 Hertz, Non-Reversing (Across-the-Line), 120V Coil Cutler Hammer, Bolted Enclosure. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No NA AE0BA2W /2 AMH /2 NA AE1BA2W /2 AMH NA AE2BA2W /2 AMH NA AE3BA2W AMH NA AE4BA2W /2 AMH NA AE5BA2W AMH8 0 5 NA AE0BA4W /2 AMH NA AE1BA4W /2 AMH NA AE2BA4W /2 AMH NA AE3BA4W AMH NA AE4BA4W /2 AMH NA AE5BA4W AMH8 0 5 NA AE0BA6W /2 AMH NA AE1BA6W /2 AMH NA AE2BA6W /2 AMH NA AE3BA6W AMH NA AE4BA6W /2 AMH NA AE5BA6W AMH8 PAGE 29
5 -30 Class I, Div. 1 and 2 AEB Series Combination Full Voltage Motor Starters With Thermal Magnetic Circuit Breakers: 3 Phase, 60 Hertz, Non-Reversing, 120V Coil Cutler Hammer, Bolted Enclosure Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No AE0BB2W1CA /2 AMH AE0BB2W1CB /2 AMH AE1BB2W1CF /2 AMH /2 50 AE1BB2W1CG /2 AMH AE2BB2W1CG /2 AMH AE2BB2W1CL /2 AMH AE3BB2W1CL /2 AMH AE3BB2W1CM /2 AMH AE4BB2W1CR /2 AMH AE4BB2W1CS /2 AMH AE5BB2W1CU AMH AE5BB2W1CV AMH AE5BB2W1CX AMH AE0BB4W1CA /2 AMH AE0BB4W1CB /2 AMH /2 30 AE1BB4W1CD /2 AMH AE1BB4W1CE /2 AMH AE2BB4W1CG /2 AMH AE2BB4W1CJ /2 AMH AE3BB4W1CN /2 AMH AE3BB4W1CP /2 AMH AE4BB4W1CQ /2 AMH AE4BB4W1CS /2 AMH AE5BB4W1CU AMH AE5BB4W1CV AMH AE5BB4W1CX AMH AE0BB6W1CA /2 AMH /2 20 AE1BB6W1CB /2 AMH AE1BB6W1CD /2 AMH AE2BB6W1CF /2 AMH AE2BB6W1CG /2 AMH AE3BB6W1CJ /2 AMH AE3BB6W1CN /2 AMH AE4BB6W1CP /2 AMH AE4BB6W1CQ /2 AMH AE5BB6W1CU AMH AE5BB6W1CV AMH8 PAGE 30
6 Class I, Div. 1 and 2-31 AEB Series Combination Full Voltage Motor Starters With MCP: 3 Phase, 60 Hertz, Non-Reversing, 120V Coil Cutler Hammer, Bolted Enclosure Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No AE0BB2W1C /2 AMH AE0BB2W1C /2 AMH AE1BB2W1C /2 AMH AE2BB2W1C /2 AMH AE3BB2W1C /2 AMH AE4BB2W1C /2 AMH AE5BB2W1C AMH AE0BB4W1C /2 AMH AE0BB4W1C /2 AMH AE0BB4W1C /2 AMH AE1BB4W1C /2 AMH AE1BB4W1C /2 AMH AE2BB4W1C /2 AMH AE2BB4W1C /2 AMH AE3BB4W1C /2 AMH AE3BB4W1C /2 AMH AE4BB4W1C /2 AMH AE5BB4W1C AMH AE0BB6W1C /2 AMH AE0BB6W1C /2 AMH AE0BB6W1C /2 AMH AE1BB6W1C /2 AMH AE1BB6W1C /2 AMH AE2BB6W1C /2 AMH AE2BB6W1C /2 AMH AE3BB6W1C /2 AMH AE3BB6W1C /2 AMH AE4BB6W1C /2 AMH AE4BB6W1C /2 AMH AE5BB6W1C AMH8 PAGE 31
7 -32 Class I, Div. 1 and 2 AEB Series Full Voltage Motor Starters: 3 Phase, 60 Hertz, Reversing, 120V Coil Cutler Hammer, Bolted Enclosure. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 0 3 NA AE0BC2W /2 AMH /2 NA AE1BC2W /2 AMH NA AE2BC2W /2 AMH NA AE3BC2W AMH NA AE4BC2W /2 AMH8 0 5 NA AE0BC4W /2 AMH NA AE1BC4W /2 AMH NA AE2BC4W /2 AMH NA AE3BC4W AMH NA AE4BC4W /2 AMH8 0 5 NA AE0BC6W /2 AMH NA AE1BC6W /2 AMH NA AE2BC6W /2 AMH NA AE3BC6W AMH NA AE4BC6W /2 AMH8 PAGE 32
8 Class I, Div. 1 and 2-33 AEB Series Combination Full Voltage Motor Starters with Thermal Magnetic Circuit Breaker: 3 Phase, 60 Hertz, Reversing, 120V Coil Cutler Hammer Bolted Enclosure. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No AE0BD2W1CA /2 AMH AE0BD2W1CB /2 AMH AE1BD2W1CE /2 AMH /2 50 AE1BD2W1CG /2 AMH AE2BD2W1CG /2 AMH AE2BD2W1CN /2 AMH AE3BD2W1CN /2 AMH AE3BD2W1CP /2 AMH AE4BD2W1CS /2 AMH AE0BD4W1CA /2 AMH AE0BD4W1CB /2 AMH /2 30 AE1BD4W1CD /2 AMH AE1BD4W1CE /2 AMH AE2BD4W1CG /2 AMH AE2BD4W1CJ /2 AMH AE3BD4W1CN /2 AMH AE3BD4W1CP /2 AMH AE4BD4W1CQ /2 AMH AE4BD4W1CS /2 AMH AE0BD6W1CA /2 AMH /2 20 AE1BD6W1CB /2 AMH AE1BD6W1CD /2 AMH AE2BD6W1CF /2 AMH AE2BD6W1CG /2 AMH AE3BD6W1CJ /2 AMH AE3BD6W1CN /2 AMH AE4BD6W1CP /2 AMH AE4BD6W1CQ /2 AMH8 PAGE 33
9 -34 Class I, Div. 1 and 2 AEB Series Combination Full Voltage Motor Starters With MCP: 3 Phase, 60 Hertz, Reversing, 120V Coil Cutler Hammer Bolted Enclosure. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No AE0BD2W1C /2 AMH AE0BD2W1C /2 AMH AE1BD2W1C /2 AMH AE2BD2W1C /2 AMH AE3BD2W1C /2 AMH AE4BD2W1C /2 AMH AE0BD4W1C /2 AMH AE0BD4W1C /2 AMH AE0BD4W1C /2 AMH AE1BD4W1C /2 AMH AE1BD4W1C /2 AMH AE2BD4W1C /2 AMH AE2BD4W1C /2 AMH AE3BD4W1C /2 AMH AE3BD4W1C /2 AMH AE4BD4W1C /2 AMH AE0BD6W1C /2 AMH AE0BD6W1C /2 AMH AE0BD6W1C /2 AMH AE1BD6W1C /2 AMH AE1BD6W1C /2 AMH AE2BD6W1C /2 AMH AE2BD6W1C /2 AMH AE3BD6W1C /2 AMH AE3BD6W1C /2 AMH AE4BD6W1C /2 AMH AE4BD6W1C /2 AMH8 * Consult factory for size of enclosure. PAGE 34
10 Class I, Div. 1 and 2-35 AEB Series Full Voltage Motor Starters: Two Speed Single Winding, 5 Pole-3 Pole, 3 Phase, 60 Hertz, 120V Coil, Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No. 0 3 NA AE0BE2W /2 AMH /2 NA AE1BE2W /2 AMH NA AE2BE2W /2 AMH NA AE3BE2W AMH NA AE4BE2W /2 AMH8 0 5 NA AE0BE4W /2 AMH NA AE1BE4W /2 AMH NA AE2BE4W /2 AMH NA AE3BE4W AMH NA AE4BE4W /2 AMH8 0 5 NA AE0BE6W /2 AMH NA AE1BE6W /2 AMH NA AE2BE6W /2 AMH NA AE3BE6W AMH NA AE4BE6W /2 AMH8 PAGE 35
11 -36 Class I, Div. 1 and 2 AEB Series Combination Full Voltage Motor Starters With Thermal Magnetic Circuit Breaker: Two Speed Single Winding, 5 Pole - 3 Pole, 3 Phase, 60 Hertz, 120V Coil Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No AE0BF2W1CB /2 AMH /2 50 AE1BF2W1CG /2 AMH AE2BF2W1CN /2 AMH AE3BF2W1CP /2 AMH AE4BF2W1CS /2 AMH AE0BF4W1CB /2 AMH AE1BF4W1CF /2 AMH AE2BF4W1CJ /2 AMH AE3BF4W1CN /2 AMH AE3BF4W1CS /2 AMH AE0BF6W1CB /2 AMH AE1BF6W1CD /2 AMH AE2BF6W1CG /2 AMH AE3BF6W1CN /2 AMH AE3BF6W1CQ /2 AMH8 PAGE 36
12 Class I, Div. 1 and 2-37 AEB Series Combination Full Voltage Motor Starters With MCP: Two Speed Single Winding, 5 Pole - 3 Pole, 3 Phase, 60 Hertz, 120V Coil Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No AE0BF2W1C /2 AMH AE0BF2W1C /2 AMH /2 30 AE1BF2W1C /2 AMH AE2BF2W1C /2 AMH AE3BF2W1C /2 AMH AE4BF2W1C /2 AMH AE0BF4W1C /2 AMH AE0BF4W1C /2 AMH AE0BF4W1C /2 AMH /2 15 AE1BF4W1C /2 AMH AE1BF4W1C /2 AMH AE2BF4W1C /2 AMH AE2BF4W1C /2 AMH AE3BF4W1C /2 AMH AE3BF4W1C /2 AMH AE4BF4W1C /2 AMH AE0BF6W1C /2 AMH AE0BF6W1C /2 AMH AE0BF6W1C /2 AMH /2 15 AE1BF6W1C /2 AMH AE1BF6W1C /2 AMH AE2BF6W1C /2 AMH AE2BF6W1C /2 AMH AE3BF6W1C /2 AMH AE3BF6W1C /2 AMH AE4BF6W1C /2 AMH AE4BF6W1C /2 AMH8 PAGE 37
13 -38 Class I, Div. 1 and 2 AEB Series Full Voltage Motor Starters: Two Speed Two Winding, 3 Pole-3 Pole, 3 Phase, 60 Hertz, 120V Coil, Cutler Hammer. Line NEMA Max Catalog Approx. Standard Mtg Hdw. Voltage Size HP Number Weight (lbs) Conduit Set Cat. No. 0 3 AE0BG2W /2 AMH /2 AE1BG2W /2 AMH AE2BG2W /2 AMH AE3BG2W AMH AE4BG2W /2 AMH8 0 5 AE0BG4W /2 AMH AE1BG4W /2 AMH AE2BG4W /2 AMH AE3BG4W AMH AE4BG4W /2 AMH8 0 5 AE0BG6W /2 AMH AE1BG6W /2 AMH AE2BG6W /2 AMH AE3BG6W AMH AE4BG6W /2 AMH8 PAGE 38
14 Class I, Div. 1 and 2-39 AEB Series Combination Full Voltage Motor Starters With Thermal Magnetic Circuit Breakers: Two Speed Two Winding, 3 Pole - 3 Pole, 3 Phase, 60 Hertz, 120V Coil Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No AE0BH2W1CB /2 AMH /2 50 AE1BH2W1CG /2 AMH AE2BH2W1CN /2 AMH AE3BH2W1CP /2 AMH AE4BH2W1CS /2 AMH AE0BH4W1CB /2 AMH AE1BH4W1CF /2 AMH AE2BH4W1CJ /2 AMH AE3BH4W1CN /2 AMH AE3BH4W1CS /2 AMH AE0BH6W1CB /2 AMH AE1BH6W1CD /2 AMH AE2BH6W1CG /2 AMH AE3BH6W1CN /2 AMH AE3BH6W1CQ /2 AMH8 PAGE 39
15 -40 Class I, Div. 1 and 2 AEB Series Combination Full Voltage Motor Starters With MCP: Two Speed Two Winding, 3 Pole - 3 Pole, 3 Phase, 60 Hertz, 120V Coil Cutler Hammer. Line NEMA Max Amp Catalog Approx. Standard Mtg Hdw. Voltage Size HP Trip Number Weight (lbs) Conduit Set Cat. No AE0BH2W1C /2 AMH AE0BH2W1C /2 AMH /2 30 AE1BH2W1C /2 AMH AE2BH2W1C /2 AMH AE3BH2W1C /2 AMH AE4BH2W1C /2 AMH AE0BH4W1C /2 AMH AE0BH4W1C /2 AMH AE0BH4W1C /2 AMH /2 15 AE1BH4W1C /2 AMH AE1BH4W1C /2 AMH AE2BH4W1C /2 AMH AE2BH4W1C /2 AMH AE3BH4W1C /2 AMH AE3BH4W1C /2 AMH AE4BH4W1C /2 AMH AE0BH6W1C /2 AMH AE0BH6W1C /2 AMH AE0BH6W1C /2 AMH /2 15 AE1BH6W1C /2 AMH AE1BH6W1C /2 AMH AE2BH6W1C /2 AMH AE2BH6W1C /2 AMH AE3BH6W1C /2 AMH AE3BH6W1C /2 AMH AE4BH6W1C /2 AMH AE4BH6W1C /2 AMH8 PAGE 40
16 Class I, Div. 1 and 2-41 AEB Series Combination Lighting Contactor With Thermal Magnetic Breaker: 3 Pole, 60 Hertz 120V Coil Cutler Hammer Line Enclosure Contactor Breaker Catalog Approx. Standard Mtg Hdw. Voltage Size Amps Amps Number Weight (lbs) Conduit (In.) Set Cat. No AE1BN1W1CF /2 AMH AE2BN1W1CJ /2 AMH AE3BN1W1CP /2 AMH AE4BN1W1CT /2 AMH AE5BN1W1CZ AMH AE1BN2W1CF /2 AMH AE2BN2W1CJ /2 AMH AE3BN2W1CP /2 AMH AE4BN2W1CT /2 AMH AE5BN2W1CZ AMH AE1BN4W1CF /2 AMH AE2BN4W1CJ /2 AMH AE3BN4W1CP /2 AMH AE4BN4W1CT /2 AMH AE5BN4W1CZ AMH AE1BN6W1CF /2 AMH AE2BN6W1CJ /2 AMH AE3BN6W1CP /2 AMH AE4BN6W1CT /2 AMH AE5BN6W1CZ AMH8 PAGE 41
17 -42 Class I, Div. 1 and 2 AEB Series Lighting Contactor: 3 Pole, 60 Hertz 120V Coil Cutler Hammer Line Enclosure Contactor Catalog Approx. Standard Mtg Hdw. Voltage Size Amps Number Weight (lbs) Conduit (In.) Set Cat. No AE1BM1W /2 AMH AE2BM1W /2 AMH AE3BM1W AMH AE4BM1W /2 AMH AE5BM1W AMH AE1BM2W /2 AMH AE2BM2W /2 AMH AE3BM2W AMH AE4BM2W /2 AMH AE5BM2W AMH AE1BM4W /2 AMH AE2BM4W /2 AMH AE3BM4W AMH AE4BM4W /2 AMH AE5BM4W AMH AE1BM6W /2 AMH AE2BM6W /2 AMH AE3BM6W AMH AE4BM6W /2 AMH AE5BM6W AMH8 PAGE 42
18 BASEPLATE -43 AEB Series Dimensions: Combination Full Voltage Motor Starter Enclosures BASEPLATE Enclosure Layout for Size 0, 1 & 2 TP VIEW BASEPLATE TP VIEW Cover bolt size: Mounting bolt size: 1/2-13 1/2-13 Note: Dimensions (in inches) are nominal. Enclosure Layout for Size 3 & 4 LEFT SIDE VIEW TP VIEW 1/2" NPT FR BREATHER DRAIN TP VIEW LEF LEFT SIDE VIEW BTTM VIEW TESER Cover bolt size: Mounting bolt size: 1/2-13 1/2-13 Note: Dimensions (in inches) are nominal. Enclosure Layout for Size 5 T TESER 1/2" NPT FR BREATHER DRAIN TP VIEW LEFT SIDE VIEW BTTM VIEW TESER 1/2" NPT FR BREATHER DRAIN TP VIEW Cover bolt size: Mounting bolt size: BTTM VIEW 5/8-11 5/8-11 PAGE 43 Note: Dimensions (in inches) are nominal.
19 -44 AEB Series Dimensions: Full Voltage Motor Starter Enclosures Enclosure Layout for Size 0, 1 & 2 Cover bolt size: 1/2-13 Mounting bolt size: 1/2-13 Note: Dimensions (in inches) are nominal. Enclosure Layout for Size 3 Cover bolt size: 1/2-13 Mounting bolt size: 1/2-13 Note: Dimensions (in inches) are nominal. PAGE 44
20 AEB Series Dimensions: Full Voltage Motor Starter Enclosures -45 Enclosure Layout for Size 4 Cover bolt size: 1/2-13 Mounting bolt size: 1/2-13 Note: Dimensions (in inches) are nominal. Enclosure Layout for Size 5 Cover bolt size: 5/8-11 Mounting bolt size: 5/8-11 Note: Dimensions (in inches) are nominal. PAGE 45
21 -46 Threaded and AEB Series Motor Starters: Modifications perators (1) Suffix Cat. No Factory Field Description Installed Installed Start/Stop Dual Pushbutton S3X AEPDGRE Stop Pushbutton S2X AEPRC Start Pushbutton S1X AEPGA Stop, Lighted PB, Red 120V LP5X AEPTRE Start, Lighted PB, Green 120V LP4X AEPTGE 3 Position Selector Switch A3X AESS31MN Specify Legend 2 Position Selector Switch A2X AESS22ML Specify Legend Red Pilot Light, 120V L5 AEPL1R Green Pilot Light, 120V L4 AEPL1G Red Pilot Light, 240V L52 AEPL2R Green Pilot Light, 240V L42 AEPL2G Red Pilot Light, 480V L54 AEPL4R Green Pilot Light, 480V L44 AEPL4G (1) Add L to part no. for Size 5 starters. NEMA 4X Breather/Drain Fittings Suffix Cat. No Factory Field Description Installed Installed Drain Fitting DN DRNB4X Breather Fitting BR BRTB4X (Drilled & tapped installation included.) Control Power ptions (2) (3) Suffix Cat. No Factory Field Description Installed Installed Fused CPT, 50va T1 AFCPT050 Fused CPT, 100va T2 AFCPT100 Fused CPT, 200va T3 AFCPT200 Fused CPT, 250va T4 AFCPT250 Fused CPT, 50va T5 AFCPT050R w/interposing Relay Fused CPT, 150va T6 AFCPT150 Fused CPT, 300va T7 AFCPT300 Fused CPT, 500va T8 AFCPT500 Fused CPT, 750va T9 AFCPT750 NTE: CPT includes primary and secondary fuses Additional ptions Description Suffix Cat. No Factory Field Installed Installed Engraved Nameplate, NP N/A Black letters on White surface, 2 x 4, 1/8 Letters, 3 Lines Max. Specify Legend verload Heater Provide FLA at the time of order. 40W Enclosure 120V -120V AFA4327X11 Space Heaters 240V -240V AFA4327X12 480V -480V AFA4327X13 Control Term. Blocks 8 point 8K N/A 20A, 600V 12 point 12K N/A NEMA 1B w/wire markers (Above 12 points consult factory) Auxiliary Contacts Cutler-Hammer Starter Aux. Contacts Suffix Cat. No Factory Field Description Installed Installed Size 0-4* 1N/1NC X11C AJ-11 2N/2NC X22C AJ-11 (2 ea.) Size 5** 1N/1NC X511C A3463D94G18 2N/2NC X522C A3463D94G18 (2ea.) Square D Starter Aux. Contacts Description Suffix Cat. No Factory Field Installed Installed Size 0-5 1N/1NC X11S A999SX8 2N/2NC X22S A999SX8 (2 ea.) * 8 Aux. Contacts Max. includes one seal-in and seven added. ** 4 Aux. Contacts Max. includes one seal-in and three added. Size 0-1 includes one seal-in and four added. Size 2-5 includes one seal-in and three added. Interrupt Ratings 14k AIC standard. Consult factory for higher interrupt capacities. Separate Control Fused Circuit S-120V N/A Specify Starter Coil Voltage S-240V N/A S-480V N/A (2) Size 1 & 2 150VA Max. Size 3 & 4 300VA Max. (3) Consult factory for other voltages. Cutler-Hammer is a trademark of the Eaton Corporation. Square D is a trademark of Groupe Schneider. PAGE 46
22 AEB Series Typical Wiring Diagram for Motor Starter Enclosures -47 Typical Wiring Diagram for Size 0-4 Typical Wiring Diagram for Size 5 PAGE 47
O-3. Compliances UL Classified UL 508, 698, 1203 NEMA 4, 4X, 7CD, 9EFG For CSA approvals, please consult factory.
Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. -3 Applications AE series threaded type combination
More informationApplications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes
AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Class I, Division and, Groups C, D Class II, Division
More informationNEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS
More informationDISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are
More informationCIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES
CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic
More informationP-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.
ALN, AN and AGN Series: Non-Factory Sealed. -9 Applications Distribution panelboards are used to furnish protection and control of electrical equipment in hazardous locations. These compact units provide
More informationProduct Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33
SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9
More informationEnclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures
Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking
More informationALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight
ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationEBMC Combination Line Starters and Enclosures
EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationDivision 1 Explosionproof Panelboards
Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:
More informationEnclosures. See Section Typical Description
January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More information3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...
Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp
More informationDBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class
More informationExplosionproof enclosures XPCJ series Cast aluminum steel control/junction box
1 TECHNICAL DATA SHEET Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box XPCJ series series of explosionproof aluminum enclosures are typically used in the packaging of electrical/electronic
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationMotor Starters Hazardous and Non-Hazardous
Motor Starters Hazardous and Non-Hazardous Description Page No. Application/Selection 342 Magnetic Line Starters & Enclosures Single speed, non-reversing EBMS Series 343-346 EPC Series 349-351 EBMS Series
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationNEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:
More informationIndustrial Control & Circuit Breakers
Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide.
More informationPowerPact B. Molded case circuit breakers and switches from A
PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member
More informationHazardous Factory Sealed Control Devices
Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)
804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit
More informationEXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight
More informationCoil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationCircuit Breakers Hazardous
s Hazardous 3C Description Page No. Application/Selection 364 Auxiliary s & s EFD, EFDC Series 382 Thermal Magnetic s & s General Information and Dimensions EPC Series 370, 371 FLB Series 375 EBMB Series
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and
More informationHazardous Duty Applications
Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks
More informationEnclosures. Section E
Enclosures Section E Enclosures and junction boxes built and configured to meet the requirements of the most demanding hazardous areas and industrial environmental applications across the globe. E Enclosures
More informationA. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:
SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationNMC Combination Line Starters and Enclosures
NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line
More informationECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9
February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR
More informationPlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationA302DN.40/.63A Thermal Current Motor Starter
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;
More informationWell-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940
Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More informationMAGNETIC MOTOR STARTERS
H A Z m MAGNETIC MOTOR Class I, Div. 1 & 2, Groups B, C, D Class l, Zones 1 & 2, Groups llb, lla Class II, Div. 1 & 2, Groups E, F, G Class III, Div. 1 & 2 ENCL. Type, 4 & 4X - File E8969 Applications
More informationCerti cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic
Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers
More informationFACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
DBR 30, 60, 100 and 150 Amp Series Receptacles Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits
More informationEnclosed Molded Case Circuit Breakers
Enclosed Motor Controllers and Molded Case Circuit Breakers KTA7 Type-E Self Protected Manual Motor Controllers Page 89 Explosion-Proof Motor Controllers KTA7_EX Page 9 The following pages contain a selection
More informationEIC combination motor starters
pplications: Harsh and hazardous motor control environments, including refineries, chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining cross-the-line starting
More informationApplications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.
Contender Series Factory Sealed Front Operated Tumbler Switches Malleable Iron Body and Cover. Furnished with Internal Ground. NEMA 3, 7CD, 9EFG Applications Designed to prevent arcing of enclosed switches
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationT&B EX TM Motor control
T&B EX TM Motor control Starters For across-the-line, manual, or magnetic motor starting, motor disconnect, motor and line protection, and stop-start operations, these starters will perform in hazardous
More informationProtection Equipment. 5/2 Introduction
Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationA. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:
SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification
More informationX1PB: Explosionproof Panelboards
X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More information4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control
. 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................
More informationCIRCUIT BREAKER PANELBOARDS
CIRCUIT BREAKER PANELBOARDS Class l, ones 1 & 2, Groups llb+h 2 Certified File LR 11713 for B7L FEATURES-SPECIFICATIONS Applications Hazardous locations due to the presence of flammable gases or vapors,
More informationD2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal
More informationStarters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types
Across the line starters & enclosed A9 AF750 Across the line Description A9 AF750 Maximum UL horsepower ratings UL508A Panel Program, #E105450 NEMA s (00 7) available Compact space-saving design Standard
More informationU-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof
U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +
More informationIEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors
04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,
More informationMotor Starter Protectors
Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker
More information3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,
Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,
More informationPlug and Play Kit Installation and Wiring (Non-Combo and Combo)
General Information This publication is to be used for Eaton Plug and Play enclosures designed starters that accept the M22 series 22mm cover control devices. To install the cover control kit (Follow the
More informationCoil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationSIGNAL WORDS QUALIFIED PERSON
SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationPoles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit
More informationPlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationProtection Equipment
Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection
More informationDry-Type Transformers Mini-Power Centers
Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant
More informationMotor Starter Protectors
Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for
More informationOverload Relay Heater Tables
Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average
More informationInstruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION
Instruction Bulletin Bulletin No. 0006-39-03 May 997 Raleigh, NC, USA Enclosed ALTISTART 6 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION This bulletin is a supplement to
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationCONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features
Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and
More informationACE20 explosionproof variable frequency drives Utilizes Allen-Bradley PowerFlex 700 drives
Cl. I, Div. 1 & 2, Groups BA, C, D (cul) NEMA 3, 4XB, 7BCD The only explosionproof VFD solution utilizing a NEMA 7 classified enclosure ACE20 explosionproof VFDs are highly flexible AC designed specifically
More informationAC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)
AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification
More informationOpen & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection
Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been
More informationPlugs and Receptacles: Hazardous Location
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable
More informationUMBW-UL489 and UL1077 Listed
-UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationESW/PESW. Non-Combination Starters
ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower
More informationWARREN COUNTY, N.Y. M/E REFERENCE
SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE
More informationExplosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC
9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB
More informationContactors & Starters Index
ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic
More informationControl Circuit Transformers
Technical Data Control Circuit Transformers Bulletin Numbers 1497, 1497A, 1497B, 1497D Topic Page Summary of Changes 1 Control Circuit Transformers Product Overview 2 Bulletin 1497 Global Control Circuit
More informationType FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers
Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page