1 -2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, I66 owerlex anelboards: Steel Enclosures Applications The owerlex anelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as petroleum refineries, chemical plants, and other process facilities. Ideal for placement in wet, corrosive environments or where flammable gases or vapors are likely to be present. Limitless flexibility through horizontal and vertical coupling options and is compact, lightweight and watertight for all your Class I, Division 2 and Class I, Zone 1 applications. Features No external conduit or cable seals required making installations faster, easier, and less costly. The owerlex anelboard features a groundbreaking design that uses individual breaker housings to minimize the downtime and costs associated with servicing circuit breakers in hazardous locations. Standard, off the shelf, Cutler- Hammer breakers are used and the lighter weight panelboard enclosure can be quickly opened in the field for easier servicing. There are no special breakers to buy. Gland plate at the bottom of the enclosure can be easily field punched for cable glands or conduit hubs. Additional gland plates available for sides and top and must be ordered with the panelboard. See options on the next page. Standard configuration includes internal actuators and a non-window door. Factory installed options include window door or external actuators. 3 circuit to 42 circuit panelboard configurations up to 60 Amps per branch breaker. For larger breaker amperage contact your local factory representative for price and availability. Branch circuit breakers available in 1, 2 and 3-pole up to 60 amps. 2 or 3-pole main circuit breakers up to 225 amps in a separate enclosure. Breakers can be padlocked in either the On or Off position. Voltage ranges from 120 to 600 volts. Factory wired. Insulated ground and neutral bars provided. External ground lug QC breaker terminal wire range #14-1/0. F Frame breaker terminal wire range #14-4/0. Accommodates standard Cutler Hammer QC Series or F-Frame series circuit breakers each individually contained in their own housing. Drain/breather included as standard. Rated -25 C to 40 C (-40 C with optional heater). Shown with Optional Window Doors Standard Materials Enclosure: 316L stainless steel. Alternate enclosure: fiberglass reinforced polyester (contact your local factory representative for price and availability). Hardware: steel. Compliances ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, I66 Cutler-Hammer is a registered trademark of Eaton Corporation. AGE 2
2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, I66 Standard Catalog Logic -3 SAMLE ANELBOARD CAT. NO. RQ S C BRANCH CIRCUITS: ( See Footnote) MAIN TYE: 1 = 100 amp lug 2 = 225 amp lug 3 = 100 amp main breaker 4 = 150 amp main breaker 5 = 200 amp main breaker 6 = 225 amp main breaker 7 = Reserved for future use 8 = Reserved for future use 9 = Special size (Contact your local factory representative for price and availability.) SYSTEM VOLTAGE: 1 = 120/240 2 = = 120/208 4 = 277/480 5 = = 347/600 7 = = Special (Contact your local factory representative for price and availability.) 1 or 2 ANEL: 1 = Single anel 2 = Double anel ANEL SIZE: anel Steel HxWxD Inches mm A 14.5x14.5x x 370 x 200 B 22x14.5x x 370 x 200 C 22x22x x 560 x 200 D 29.5x22x x 560 x 200 E 44.5x29.5x x 750 x 300 Ordering Instructions Standard anels: 1. Select panel from the chart on page -4. anels are available as either QC or F-frame branch breakers. 2. Complete branch circuit information using the example below. 3. Add the branch circuit information as a suffi x to the panel board catalog number. Example: RQSC DV = C size enclosure 12 QC circuits maximum, 225A main lug, (3) 15A 1-pole, (3) 20A 2-pole, and (6) 30A 3-pole branch breakers and optional drain/breather. 4. Choose options from available list below and add suffi xes to catalog number. Optional anels: 1. Construct panel board catalog logic. 2. Complete steps 2-4 above. 3. Contact your local factory representative for price and availability. Maximum Number of Circuits BREAKER TYE ANEL QC F-FRAME A 3 3 B - 3 C 12 - D E ANEL MATERIAL: SERIES & BREAKER TYE: S = 316 SST = Glass Reinforced olyester (GR) RQ = owerlex panel w/ QC Breakers RF = owerlex panel w/ F Breakers Main breaker is EHD Series. Breaker housing is currently rated 10 kaic maximum. For higher kaic ratings contact your local factory representative for price and availability. Branch Circuit Example: = (3) 15A 1-pole, (3) 20A 2-pole, (6) 30A 3-pole Type of branch breakers used: Breakers are contained within a single housing. Each breaker housing accommodates: (3) 1-ole or (1) 1-ole & (1) 2-ole or (1) 3-ole The above example totals 9 breaker housings. QC: 1-, 2- and 3-ole 40A max. 10KAIC. QCHW 2 and 3-ole 60A max. 22 KAIC. F- frame: EHD, FD, FDB 1, 2, or 3-ole KAIC. AGE 3
3 -4 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, I66 Options and Specifications Factory Installed Options: Description Add Suffix Description Add Suffix Breaker operators on door (riced per breaker) L Thermostatically controlled heater HTR Main breaker inside panel (rice on application) M Grounded neutral GN Terminal blocks instead of direct wiring TB henolic nameplate (Specify Legend) N Additional drain/breather DV Window with interal operators W Gland plate (specify GL = left side, GR = right side, NG = no gland plate) LED indicator lights G IL Door padlocking provision steel legend plate (Specify Legend) S F-Frame anelboard Specifications Direct Wiring No Terminal Block # of Branch anel Size Main Breaker Circuit anel (H X W X D) Breakers A B D E 370 x 370 x 200 (14.5 x 14.5 x 7.9) 560 x 370 x 200 (22 x 14.5 x 7.9) 750 x 560 x 200 (29.5 x 22 x 7.9) 1130 x 750 x 300 (44.5 x 29.5 x 11.8) None None Amps 3 60 Amps Amps None Amps Amps Amps QC-Frame anelboard Specifications Direct Wiring No Terminal Block anel A C D E anel Size (H X W X D) 370 x 370 x 200 (14.5 x 14.5 x 7.9) 560 x 560 x 200 (22 x 22 x 7.9) 750 x 560 x 200 (29.5 x 22 x 7.9) 1130 x 750 x 300 (44.5 x 29.5 x 11.8) Main Breaker # of Branch Circuit Breakers 3 40 Amps Amps Amps Amp Circuit Breaker Specifications F-Frame Circuit Breaker Specifications QC-Frame Circuit Breaker Specifications Interrupting Capacity (Symmetrical Amperes) Breaker Number of Interrupting Capacity (Symmetrical Amperes) Breaker Number Volts Volts DC Type oles Volts Type of oles EHD 1 14,000 10,000 QC 1 (max 40A) 10,000 10,000 EHD 2, 3 18,000 14,000 10,000 QC 2, 3 (max 40A) 10,000 10,000 FDB 2, 3 18,000 14,000 14,000 10,000 AGE 4
4 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, I66 owerlex anelboard -5 Main Type 100A Main Lug Only 225A Main Lug Only 100A Main Breaker * (In separate satellite box) 150A Main Breaker * (In separate satellite box) 200A Main Breaker * (In separate satellite box) 225A Main Breaker * (In separate satellite box) anel Material anel Size Max. No. of Circuits 120V/240V 1 hase 3 Wire QC Type 120V/208V 3 hase 4 Wire QC Type SINGLE ANEL 277V/480V 3 hase 4 Wire F-Frame 480V 3 hase 3 Wire F-Frame C 12 RQSC111 RQSC131 D 12 RFSD141 RFSD151 D 24 RQSD111 RQSD131 E 24 RFSE141 RFSE151 E 42 RQSE111 RQSE131 F 42 RFSF141 RFSF151 C 12 RQSC112 RQSC132 D 12 RFSD142 RFSD152 D 24 RQSD112 RQSD132 E 24 RFSE142 RFSE152 E 42 RQSE112 RQSE132 F 42 RFSF142 RFSF152 C 12 RQSC113 RQSC133 D 12 RFSD143 RFSD153 D 24 RQSD113 RQSD133 E 24 RFSE143 RFSE153 E 42 RQSE113 RQSE133 F 42 RFSF143 RFSF153 C 12 RQSC114 RQSC134 D 12 RFSD144 RFSD154 D 24 RQSD114 RQSD134 E 24 RFSE144 RFSE154 E 42 RQSE114 RQSE134 F 42 RFSF144 RFSF154 C 12 RQSC115 RQSC135 D 12 RFSD145 RFSD155 D 24 RQSD115 RQSD135 E 24 RFSE145 RFSE155 E 42 RQSE115 RQSE135 F 42 RFSF145 RFSF155 C 12 RQSC116 RQSC136 D 12 RFSD146 RFSD156 D 24 RQSD116 RQSD136 E 24 RFSE146 RFSE156 E 42 RQSE116 RQSE136 F 42 RFSF146 RFSF156 * Main circuit breakers are EHD series. Branch circuit breakers are EHD. For FD or FDB contact your local factory representative for price and availability. AGE 5
5 -6 Size A 3 Circuit F-Frame 60A Max mm mm mm mm mm mm mm mm mm Size B 3 Circuit F-Frame 255A Max (MCB) mm mm mm mm mm mm mm.91 23mm 7.87 (Used as a main circuit breaker in the position shown) AGE 6
6 owerlex anelboard: -7 Size D 12 Circuit F-Frame mm mm mm mm mm mm mm mm Effective May, October, AGE 7
7 -8 Size E 24 Circuit F-Frame mm mm mm mm mm mm mm mm mm mm AGE 8
8 owerlex anelboard: -9 Size C 12 Circuit QC mm mm mm mm mm mm mm Size D 24 Circuit QC mm mm mm mm mm mm mm mm mm mm AGE 9
9 -10 Size E 42 Circuit QC mm mm mm mm mm mm mm mm mm AGE 10
PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationPlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationPOWERPLEX PANELBOARD 1
1 POWERPLEX PANELBOARD 2 ADVANCING PANELBOARD TECHNOLOGY WITH COMPONENT LEVEL PROTECTION. Introducing the PowerPlex Panelboard. Appleton's PowerPlex Panelboard changes the face of hazardous location panelboards
More informationPLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE
PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE EASY TO INSTALL, OPERATE AND MAINTAIN. PlexPower Panelboards use circuit breaker modules that provide explosionproof protection for standard off-the-shelf
More informationP-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.
ALN, AN and AGN Series: Non-Factory Sealed. -9 Applications Distribution panelboards are used to furnish protection and control of electrical equipment in hazardous locations. These compact units provide
More informationEXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS
EXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS EASY TO INSTALL, OPERATE AND MAINTAIN. PlexPower Panelboards use circuit breaker modules that provide explosionproof protection
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationExplosionproof Protection Simplified
Explosionproof Protection Simplified Appleton Plexpower Lighting and Power Panelboards Product Overview Brochure Easy To Install, Operate and Maintain. The Appleton PlexPower Panelboards by Emerson use
More informationDivision 1 Explosionproof Panelboards
Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting
More informationP SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE
P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE A BREAKER PROTECTION BREAKTHROUGH Simplify flameproof protection for lighting, heat trace and power circuit distribution with the new generation
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More informationCIRCUIT BREAKER PANELBOARDS
CIRCUIT BREAKER PANELBOARDS Class l, ones 1 & 2, Groups llb+h 2 Certified File LR 11713 for B7L FEATURES-SPECIFICATIONS Applications Hazardous locations due to the presence of flammable gases or vapors,
More informationPanelboard Protection on a Global Scale
Panelboard Protection on a Global Scale Appleton Panelboards Brochure Selection guide. No matter what environment, location or power requirement, our panelboards have your facility covered. From a petrochemical
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationX1PB: Explosionproof Panelboards
X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel
More informationDBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class
More informationFACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationGREATER VERSATILITY WITH LESS DOWNTIME
GREATER VERSATILITY WITH LESS DOWNTIME PlexPower Distribution Panelboards EASY TO INSTALL, OPERATE AND MAINTAIN. The PlexPower panelboard is engineered to meet your precise requirements today. Easily upgradeable
More informationD2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal
More informationNEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
DBR 30, 60, 100 and 150 Amp Series Receptacles Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations
More informationALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight
ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards
More informationCircuit Breakers Hazardous
s Hazardous 3C Description Page No. Application/Selection 364 Auxiliary s & s EFD, EFDC Series 382 Thermal Magnetic s & s General Information and Dimensions EPC Series 370, 371 FLB Series 375 EBMB Series
More informationEylander Electric Inc
Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL
More informationEXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable
More informationPower distribution SynergEX panelboards. SynergEX. Class I, Division 2 panelboards
Power distribution SynergEX panelboards SynergEX Class I, Division 2 panelboards SynergEX panelboards for hazardous rated areas Maximum safety. Easy access, lower risk and less downtime. One of the biggest
More informationSynergEX Panelboards for Hazardous Locations
SynergEX Panelboards for Hazardous Locations Installation & Maintenance Information 1. APPLICATION SynergEX panelboards provide short circuit protection for feeder or branch circuits to control lighting,
More informationEBMC Combination Line Starters and Enclosures
EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,
More informationDISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are
More informationHKH Series. HAZCON Controls for Harsh and Hazardous Environments
HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective
More informationNEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS
More informationATX DPD Series Distribution Panelboards Flameproof
ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:
More informationDry-Type Transformers Mini-Power Centers
Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant
More informationMotor Starters Hazardous and Non-Hazardous
Motor Starters Hazardous and Non-Hazardous Description Page No. Application/Selection 342 Magnetic Line Starters & Enclosures Single speed, non-reversing EBMS Series 343-346 EPC Series 349-351 EBMS Series
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed
More informationSTAINLESS STEEL PANEL MOUNT
Z A H LO C STAINLESS STEEL PANEL MOUNT Optional Legend Plate Cover Screw Retaining Washer Panel Mount Bracket Explosion Protective LED Pilot Light Stainless Steel Washer Actuator Spacer Locknut Explosion
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationFactory Sealed Panelboards
FACTORY SEALED PAELBOARDS Factory Sealed Designed for use In Class I, Division 2 and Class I, Zone 2 areas such as petroleum refineries, chemical or petrochemical facilities, the factory sealed panelboards
More informationJunction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety
JBES Series Medium Voltage 11 kv ECES Series Compliance Data: ATEX - IEC: ATEX IEC CE Ex e II Ex ia IIC; Ex ib IIC T6 to T4 Ex td A21 T80 C to T130 C Ex de IIC; Ex demb IIC Operating Temperatures: -50
More informationPlugs and Receptacles: Hazardous Location
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable
More informationStandard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors
More informationHazardous Factory Sealed Control Devices
Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot
More informationSeries C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker
FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type
More informationU-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof
U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +
More informationSafety Alert: Square D Safety Switches
Safety Alert: Square D Safety Switches Be Sure to Inspect Your Installed Units for Defects Schneider Electric has issued an offer safety alert on the Square D safety switch due to electrical shock hazard
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationMercmaster LED Series Luminaires Enclosed and Gasketed Fixtures
Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical
More informationGHG43 Series Control Stations
GHG43 Series Control Stations Nonmetallic or 316L Stainless Steel UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, (A) Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cul) PTB ATEX
More informationAmperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225
January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More informationJBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped
Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For
More informationAPPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications
Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection
More informationTable Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units
-22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More information100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E
100-Ampere Busway Technical Data TD01701002E Effective November 2005 New Information Elbow, Busway and Cable Tap Box Contents General Information.............................. 2 Connections...............................
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More informationIndustrial Control & Circuit Breakers
Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide.
More informationSpring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs
More informationSolar Combiner Solutions
Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from
More informationA. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:
SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification
More informationArktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed
Arktite Circuit Breaking CPS Application: CPS receptacles, angle and straight types, and CPP plugs are used: with portable electrically operated devices such as motor-generator sets, compressors, conveyors,
More informationNMC Combination Line Starters and Enclosures
NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line
More information14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB H0N
14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB141207-4H0N Applications and Features Features: Molded Fiberglass Reinforced Polyester (FRP)
More informationCable-Operated Disconnect Switches. Accessories
Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches
More informationApplications. Illustrated Features
Applications For use in locations where a high degree of corrosion resistance is required. FR Series: For use in areas where high humidity or water vapor are present Typical uses include meat- or food-processing
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More information3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...
.6 Panelboards and Lighting Control PRC25 Panelboard PRC25 Panelboard Product The PRC25 panelboard is designed to meet the needs for control of lighting and small branch circuits. Used as a standalone
More informationPANELBOARDS SECTION 1
SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector
More informationBenefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine
eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components
More informationStandard Materials Bodies and covers: copper-free aluminum.
-26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001
2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed
More informationEnclosed Rotary Switch Product Specification Sheets Table of Contents
Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX
More informationSeries C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationHeavy Duty Safety Switches
eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................
More information1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".
SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,
More informationJefferson Electric Class I Division 2 Transformers for hazardous locations
Class I Division 2 Jefferson Electric Class I Division 2 Transformers for hazardous locations Jefferson Electric offers a full line of Class I Division 2 transformers. Jefferson Electrics Class I Division
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationEngine Generator Circuit Breakers
Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits
More information4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)
4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are
More information6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions
.1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design
More informationCIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES
CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic
More informationPANELBOARDS C1/C2 SECTION 6
SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2
More informationArktite Plugs and Receptacles Industrial Heavy Duty Hazardous
Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Description Page No. Application/Selection 1000, 1001 Arktite Delayed Action Circuit Breaking Technical Data 1002, 1003 20 & 30A CPS Receptacle
More informationSwitchboards Instant Service
January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8
More informationEOEM panelboard and switchboard (OPS) Program
Instructional Leaflet IL02009EN EOEM panelboard and switchboard (OPS) Program OPS Program overview The OPS Program enables EOEMs to purchase panelboard/switchboard chassis, boxes, trims, molded-case circuit
More informationTERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS
OSUR CL HA ES EN KILLARK Z LO C SJIC SERIES TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS Screw cover style, with or without continuous hinge 3/16 (5mm) wide flat flange for maximum gasket surface
More informationMeter Mains - Without Bypass
- 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat
More informationArktite Heavy Duty Circuit Breaking Plugs and Connectors
Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.
More informationCutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF
Cutler-Hammer Breakers American International Marketing Portland OR 97291-033 Closeout #1287-Cutler-Hammer-Breakers Cutler Hammer Ground-Fault Or Arc-Fault Breaker GFEP120 Cutler Hammer Ground-Fault Equipment
More information