Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families

Size: px
Start display at page:

Download "Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families"

Transcription

1 Modular Metering Stock Selection Guide Meter Mod * III and Mini Mod * III Product Families

2 Table of Contents Page No. Nomenclature 3 Main Breaker Module, Single-Phase, 3 Wire, 0/40 Vac 4 Main Breaker Module, Single-Phase, 3 Wire, 0/40 Vac with Arc Reduction Means 4 Main Breaker Module, Three-Phase, 4 Wire, 08Y/0 Vac or Three-Phase, 4 Wire, 0/40V Delta Hi-Leg 5 Main Breaker Module, Three-Phase, 4 Wire, 08Y/0 Vac or Three-Phase, 4 Wire, 0/40V Delta Hi-Leg with Arc Reduction Means 5 Main Breaker Module Accessories: Alternate Rating Plugs and Shunt Trips 6 Main Fusible Switch Module, Single-Phase, 3 Wire 0/40 Vac 7 Main Fusible Switch Module, Three-Phase, 4 Wire 08Y/0 Vac 7 Main Fusible Switch Modules - Fuses and Compression Lugs 8 Main Lug Module Single-Phase, 3 Wire 0/40 Vac 9 Main Lug Module Three-Phase, 4 Wire 08Y/0 Vac 9 Meter Stack Modules, Residential, Single-Phase, 800 Amp Horizontal Bussing, 5 & 00A Sockets 0 Meter Stack Modules, Residential, Single-Phase, 800 Amp Horizontal Bussing, 5 & 00A Sockets - MEG Approved Meter Stack Modules, Residential, Single-Phase, 00 Amp Horizontal Bussing, 5 & 00A Sockets Meter Stack Modules, Residential, Single-Phase, 00 Amp Horizontal Bussing, 5 & 00A Sockets - MEG Approved Tenant Main Breakers for PH Residential Meter Modules (800A & 00A Horizontal Bussing) 3 Meter Mod III - Residential Meter Stacks - Field Installed Accessories 4 Meter Stack Modules, Commercial, Single-Phase, 5A/400A Ringless Sockets w/lever Bypass 5 Tenant Main Breakers for PH Commercial Meter Stack Modules (00A Horizontal Bussing) 6 Meter Stack Modules, Commercial, Three-Phase, 5A/400A Ringless Sockets w/ Lever Bypass 7 Tenant Main Breakers for 3PH Commercial Meter Stack Modules (00A Horizontal Bussing) 8 Meter Mod III - Commercial Meter Stacks - Field Installed Accessories 9 Mini Mod III Ring -Type and Ringless 9 Mini Mod III Ring -Type and Ringless - MEG Approved 5A & 00A Sockets 0 Tenant Main Breakers for Mini Mod Product Family Mini Mod III Field Installed Accessories Other Publications and References 4

3 Mini Mod III Nomenclature T MM R F GE Identification Type MM = Mini Mod Ring Type MMR = Mini Mod Ringless Socket Rating Horizontal Bus Rating = 5A = 00A 0 = 00A 4 = 400A 6 = 600A Socket Positions -6 Additional Features F = MEG Approved Enclosures R = Type 3R Rainproof Meter Mod III - Main Nomenclature T MP 3 SB 8 R AR GE Identification Type MP = Meter Mod III Insert for 3-Phase Type SB = Main Breaker, Top/Bottom Feed (400-00A) SHB = Main Breaker, High Interrupting, Top/Bottom Feed (400-00A) BB = Main Breaker, Bottom Feed ( A) BT = Main Breaker, Top Feed ( A) BU = Main Breaker with Integral Pull Box - EUSERC FT = Main Switch, Top Feed FB = Main Switch, Bottom Feed L = Main Lug U = Main Pull Box Additional Features AR = Arc Reduction CRIS = Copper, Riser Enclosures R = Type 3R Rainproof CLL = Compression Lug Landing Kit Included ST = Shunt Trip, Factory Installed Maximum Ampere Rating 4 = 400A 6 = 600A 8 = 800A 0 = 000A = 00A 4 = 400A 6 = 600A 0 = 000A Meter Stack Nomenclature GE Identification Type MP = Meter Mod Ring Type MPR = Meter Mod Ringless MPK = Meter Mod K-Base Socket Insert for 3-Phase Horizontal Bus Rating 8 = 800A = 00A T MP T R F Socket Rating = 5A 0 = 00A = 5A 40 = 400A Socket Positions -6 Special MEG Approved Enclosures R = Type 3R Rainproof Insert for Tenant Breakers 3

4 Main Breaker Module, Single-Phase, 3 Wire 0/40 Vac Breaker included. 80% Rated MCB Single-phase mains have a neutral, A-phase, B-phase and ground and may be connected to three-phase horizontal bus stacks. However, output is only single-phase. All mains are required to be center feed only when main breaker is greater than horizontal bus amps Catalog Number Main Ampere Rating IC Rating Max kaic TMPSB4R TMPSHB4R 00 TMPSB6R TMPSHB6R 00 Feed Location 0-40Vac Shunt Trip Main Breaker Frame Bottom No SGH400 Bottom No SGH600 AWG/kcmil Cu/Al - Phase Al: () /0-500 or () Cu: /0-400 or () Al: () /0-500 or () Cu: /0-400 or () AWG/kcmil Cu/Al - Neutral () -600 () -600 TMPSB8R Bottom No SKH800 Al/Cu (3) 3/0-500 (4) TMPSB0R Bottom No SKH00 Al: (4) Cu: (4) 50/350 (4) TMPSBR Bottom No SKH00 Al: (4) Cu: (4) 50/350 (4) TMPBB4R 3 Bottom RG (4) kcmil (4) No TMPBT4R 3 Top RG (4) kcmil Al/Cu (4) TMPBB6R 3 Bottom TMPBB6RST 3 Bottom Yes TMPBT6R 3 Top No TMPBT6RST 3 Top Yes TMPBT0R TMPBB0R 3 Top Bottom No RG Al/Cu (4) kcmil Al/Cu (4) No RG (6) # 600 kcmil (6) # 600 kcmil Optional lug TCAL4 field installed wire range (3) kcmil. Optional neutral lug field installed wire range (3) /0-750 kcmil. Lug kit part number TMPL Fixed Rating Plug not Field adjustable. 4 To meet NEC 04 Arc Energy Reduction (Section 40.87), please use a 75A rating plug. Product number SPRK00A75, order separately Main Breaker Module, Single-Phase, 3 Wire 0/40 Vac with Arc Reduction Means Breaker included. 80% Rated MCB Single-phase mains have a neutral, A-phase, B-phase and ground and may be connected to three-phase horizontal bus stacks. However, output is only single-phase. All mains are required to be center feed only when main breaker is greater than horizontal bus amps The main breaker in this section has an arc reduction means that satisfies the requirement of NEC 04 Section Amperage Phase IC Rating Max kaic Feed Catalog Number Description AWG/kcmil Cu/Al - Phase AWG/kcmil Cu/Al - Neutral 400A to Less Than 00A Top or Bottom Use Standard Part #. Code effects only 00A and greater 00A Top or Bottom Use 400 or 600A and advise GE sales rep to make trip unit 00A 400A 00 Bottom TMPBB4RAR 400A Ph Main Breaker Bottom Feed - Arc Reduction (4) (4) A 00 Bottom Top TMPBB6RAR TMPBT6RAR 400A Ph Main Breaker Bottom Feed - Arc Reduction 600A Ph Main Breaker Top Feed - Arc Reduction (4) (4) A 00 Bottom TMPBB0RAR 000A Ph Main Breaker Bottom Feed - Arc Reduction (6) #-600 (6) #-600 NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs but have factory installed trip units. If you need a trip setting that is different than the frame, please your GE sales rep at time of order entry and they will work with the factory to manually change this. For example, if you want a TMP3BB6RAR (600A frame) with 00A trip. 4

5 Main Breaker Module, Three-Phase, 4 Wire 08Y/0 Vac or Three-Phase, 4 Wire, 0/40V Delta Hi-Leg Breaker included. 80% Rated MCB. All mains are required to be center feed only when main breaker is greater than horizontal bus amps Catalog Number TMP3SB4R Main Ampere Rating IC Rating Max kaic 65 Feed Location 0-40 Vac Shunt Trip Main Breaker Frame AWG/ kcmil Cu/Al -Phase Al: () /0-500 or () Cu: /0-400 or () AWG/kcmil Cu/Al - Neutral 400 Bottom No SGH400 () -600 TMP3SHB4R 00 TMP3SB6R 65 Al: () /0-500 or () Bottom No SGH600 () -600 TMP3SHB6R 00 Cu: /0-400 or () TMP3SB8R Bottom No SGH800 Al/Cu (3) 3/0-500 (4) TMP3SB0R Bottom No SGH00 Al: (4) Cu: (4) 50/350 (4) TMP3SBR Bottom No SKH00 Al: (4) Cu: (4) 50/350 (4) TMP3BB4R 3 Bottom TMP3BT4R 3 Top No RG (4) kcmil (4) TMP3BB6R 3 No RG Al/Cu (4) Al/Cu (4) TMP3BB6RCLL 3 Bottom No RG Compression Lugs Compression Lugs TMP3BB6RST Yes TMP3BT6R 3 No RG Al/Cu (4) Al/Cu (4) Top TMP3BT6RST 3 Yes TMP3BT0R 3 Top TMP3BB0R 3 Bottom No RG (6) # 600 kcmil (6) # 600 kcmil TMP3BB0RCLL Bottom RG Compression Lugs Compression Lugs TMP3BT0RST 3 Top TMP3BB0RST 3 Bottom Yes RG (6) # 600 kcmil (6) # 600 kcmil Optional lug TCAL4 field installed wire range (3) kcmil. Optional neutral lug field installed wire range (3) /0-750 kcmil. Lug kit part number TMPL Fixed Rating Plug not Field adjustable. 4 To meet NEC 04 Arc Energy Reduction (Section 40.87), please use a 75A rating plug. Product number SPRK00A75, order separately Main Breaker Module, Three-Phase, 4 Wire 08Y/0 Vac or Three-Phase, 4 Wire, 0/40V Delta Hi-Leg with Arc Reduction Means Breaker included. 80% Rated MCB. All mains are required to be center feed only when main breaker is greater than horizontal bus amps The main breaker in this section has an arc reduction means that satisfies the requirement of NEC 04 Section Amperage 400A to Less Than 00A Phase 3 00A 3 IC Rating Max kaic 400A A A 3 00 Feed Catalog Number Description Top or Bottom Top or Bottom Bottom Top Bottom Top Top Bottom Use Standard Part #. Code effects only 00A and greater Use 400 or 600A and advise GE sales rep to make trip unit 00A TMP3BB4RAR TMP3BT4RAR TMP3BB6RAR TMP3BT6RAR TMP3BT0RAR TMP3BB0RAR 400A 3Ph Main Breaker Bottom Feed - Arc Reduction 400A 3Ph Main Breaker Top Feed - Arc Reduction 600A 3Ph Main Breaker Bottom Feed - Arc Reduction 600A 3Ph Main Breaker Top Feed - Arc Reduction 000A 3Ph Main Breaker Top Feed - Arc Reduction 000A 3Ph Main Breaker Bottom Reed - Arc Reduction AWG/kcmil CU/AL - Phase AWG/kcmil CU/AL - Neutral (4) (4) (4) (4) (6) #-600 (6) #-600 NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs but have factory installed trip units. If you need a trip setting that is different than the frame, please contact your GE sales rep at time of order entry and they will work with the factory to manually change this. For example, if you want a TMP3BB6RAR (600A frame) with 00A trip 5

6 Main Breaker Module Accessories Main Breaker Modules Alternate Rating Plugs Field installed Breaker Frame Rating () Trip Rating () Rating Plug Part No. 5 SRPG400A5 400A 50 SRPG400A SRPG400A SRPG400A SRPG600A SRPG600A A 350 SRPG600A SRPG600A SRPG600A SRPG600A SRPK800A SRPK800A A 500 SRPK800A SRPK800A SRPK800A SRPK00A SRPK00A700 00A 800 SRPK00A SRPK00A SRPK00A SRPK00A75 Shunt Trip Field Installed For use on all Main Breaker Modules Shunt Trip Catalog Number 0 Vac SAST 40 Vac SAST 6

7 Main Fusible Switch Module, Single-Phase, 3 Wire 0/40 Vac Single-phase mains have a neutral, A-phase, B-phase group and may be connected to three-phase horizontal bus stacks. However, output is only single-phase All mains are required to be center feed only when the main fusible switch rating is greater than the horizontal bus amperage rating Catalog Number Main Ampere Rating TMPFT4R 400 IC Rating (Max) kaic Wire Entry AWG/kcmil Cu/Al -Phase () /0-750 or () /0-300 AWG/kcmil Cu/Al - Neutral () /0-750 or () /0-300 TMPFT6R 600 () -600 () -600 TMPFT8R Top (4) 3/0-750 (4) 3/0-750 TMPFTR TMPFTRST 5 00 (4) -500 (4) -500 () /0-750 or () /0-750 or TMPFB4R 400 () /0-300 () / Bottom TMPFB6R 600 () -600 () -600 TMPFB8R 800 (4) 3/0-750 (4) 3/0-750 TMPFBRT Bottom (4) -500 (4) -500 Stud Sets per Phase and Neutral Fuse Not Included. Order Separately. Compression Lug Landing Kit Class T only Order Separately Class L only. Bolted Pressure Switch Class T only Order Separately see footnote TMPFBR see footnote TMPFBRST 5 TMPFBRT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMPFBR, but is significantly less expensive. TMPFBR is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMPFBRT, but more expensive. Main Fusible Switch Module, Three-Phase, 4 Wire 08Y/0 Vac Fuses not included. All mains are required to be center feed only when the main fusible switch rating is greater than the horizontal bus amperage rating Catalog Number Main Ampere Rating TMP3FT4R 400 IC Rating (Max) kaic Wire Entry AWG/kcmil Cu/Al -Phase () /0-750 or () /0-300 AWG/kcmil Cu/Al - Neutral () /0-750 or () /0-300 TMP3FT6R 600 () -600 () -600 TMP3FT8R 800 (4) 3/0-750 (4) 3/0-750 TMP3FTR TMP3FTRST 5 TMP3FT6R TMP3FT6RST 5 TMP3FT0R TMP3FT0RST 5 TMP3FB4R Top (4) (4) (6) (6) (8) (8) () /0-750 or () /0-300 () /0-750 or () /0-300 TMP3FB6R 600 () -600 () -600 TMP3FB8R 800 (4) 3/0-750 (4) 3/0-750 Stud Sets per Phase and Neutral Fuse Not Included. Order Separately. Class T only Class L only. Bolted Pressure Switch Class T only TMP3FBR 4 00 (4) (4) See footnote 4 TMP3FBRT Bottom (4) -600 (4) -600 See footnote 3 TMP3FBRST 5 00 (4) (4) TMP3FB6R 600 (6) (6) TMP3FB6RST (6) (6) TMP3FB0R 000 (8) (8) TMP3FB0RST (8) (8) Class L only. Bolted Pressure Switch Compression Lug Landing Kit TMP3F8CLL Order Separately TMP3F8CLL Order Separately 3 TMP3FBRT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMP3FBR, but is significantly less expensive. 4 TMP3FBR is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMP3FBRT, but more expensive. 5 Product numbers ending in ST have shunt tripping style bolted pressure switch. 7

8 Main Fusible Switch Modules Fuses and Compression Lugs Class T Fuses Rated at 40V Class L Fuses Rated at 40V Frame Size Ampere Rating Catalog Number 50 TFUSE TFUSE TFUSE TFUSE TFUSE TFUSE TFUSE A3T00 Ampere Rating Catalog Number 600 A4BY A4BY A4BY A4BY A4BY A4BY A4BY A4BY00 Ampere Rating Catalog Number 00 A4BY A4BY A4BY A4BY A4BY A4BY A4BY000 Compression Lugs The following UL listed crimp connectors may be used Wire size (CU only) Mac T & B Burndy Panduit 50 kcmil 300 kcmil 350 kcmil 400 kcmil 500 kcmil 600 kcmil MSB50-8N MRB50-8N MSB300-8N MRB300-8N MSB350-8N MRB350-8N MSB400-8N MRB400-8N MSB500-8N MRB500-8N MSB600-8N MRB600-8N BE BE BE 54874BE BE BE 700 kcmil kcmil Wire size (AL/CU) 50 kcmil 300 kcmil 350 kcmil 400 kcmil 500 kcmil 600 kcmil MSB750-8N MRB750-8N MLB50-8N MULB50-8N MLB300-8N MULB300-8N MLB350-8N MULB350-8N MLB400-8N MULB400-8N MLB500-8N MULB500-8N MLB600-8N MULB600-8N BE kcmil 6077 YA9-LN YA9-LN YA30-LN YA30-LN YA3-LN YA3-LN YA3-LN YA3-LN YA34-LN YA34-LN YA36-LN YA36-LN YA39-LN YA39-LN YA9A3 YA9AY-N YA30A3 YA30AY-N YA3A3 YA3AY-N YA3A3 YA3AY-N YA34A3 YA34AY-N YA36A3 YA36AY-N LCC50- LCC300- LCC350- LCC400- LCC500- LCC750- LAB50- LAB300- LAB350- LAB400- LAB500- LAB kcmil YA39A5 LAB750- Note: torque / nuts which attach crimp connectors to 45 ft.-lb. (6 N-m) 8

9 Main Lug Module, Single-Phase, 3 Wire 0/40 Vac Lugs included. Catalog Number Main Ampere Rating Use 3-Phase 400 Use 3-Phase 600 TMPL8R 800 TMPLR 00 IC Rating (Max) kaic 00 Wire Entry Bottom/ Top Mounting End or Center AWG/ kcmil Cu/Al - Phase () /0-750 or (4) /0-300 (3) /0-750 or (6) /0-300 AWG/kcmil Cu/Al - Neutral () /0-750 or (4) /0-300 (3) /0-750 or (6) /0-300 Stud Sets per Phase and Neutral TMPL6R 600 (6) (6) Limited to the lowest marked short circuit rating of the main and meter modules used. 3 Compression Lug Landing Kit Order Separately Main Lug Module, Three-Phase, 4 Wire 08Y/0 Vac Lugs included. Catalog Number TMP3L4R TMP3L4RCU TMP3L6R TMP3L6RCU TMP3L8R TMP3L8RCU Main Ampere Rating 400 IC Rating (Max) kaic 00 Wire Entry Bottom/ Top Mounting End or Center AWG/ kcmil Cu/Al - Phase () or () /0-50 AWG/kcmil Cu/Al - Neutral () or () /0-50 Stud Sets per Phase and Neutral 600 () () TMP3LR 00 () /0-750 or (4) /0-300 (3) /0-750 or (6) /0-300 () /0-750 or (4) /0-300 (3) /0-750 or (6) /0-300 TMP3L6R 600 (6) (6) TMP3L0R 000 (8) /0-750 (8) /0-750 Limited to the lowest marked short circuit rating of the main and meter modules used. Copper bused. Compression Lug Landing Kit Order Separately Main Lug with Feed Through, Three Phase, 4 Wire / Single Phase, 3 Wire 0/40 Vac, 08Y/0 Vac Catalog Number Main Amperage KAIC Incoming Line Outgoing Load Stud Sets per Phase and Neutral Compression Lug Landing Kit TMP3LRCRIS 00A (5) Up to 750 MCM per Phase/Neutral (AL/CU) (5) Up to 750 MCM per Phase/Neutral (AL/CU) TMP3L6RCRIS 600A 00 TMP3L0RCRIS 000A (8) /0-750 MCM per Phase/Neutral (AL/CU) (8) /0-750 MCM per Phase/Neutral (AL/CU) 9

10 Meter Stack Modules Residential Single Phase 800A Horizontal Bussing 5 & 00A Sockets 800 amp, 4 Wire Crossbus (Aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Socket 5 00 No. of Sockets Ring Type Socket Catalog Number Ringless Type Socket (4 Jaw Socket Standard) Ringless Type Socket (4 Jaw Socket Standard) Horned Bypass Factory Installed TMP8R TMPR8R TMPR8RHB 3 TMP83R TMPR83R TMPR83RHB 4 TMP84R TMPR84R TMPR84RHB 5 TMP85R TMPR85R TMPR85RHB 6 TMP86R TMP8R6R TMP8R6RHB TMP80R TMPR80R TMPR80RHB 3 TMP830R TMPR830R TMPR830RHB 4 TMP840R TMPR840R TMPR840RHB 5 TMP850R TMPR850R TMPR850RHB 5 TMP850RBUS, TMPR850RBUS TMPR850RHBBUS One snap-type, aluminum sealing ring (TSR5) per socket included BUS suffix indicates change to centerline of horizontal bussing from 8.88" to 4.0" from bottom of unit 800 amp, 4 Wire Cross bus (copper) - CON ED Approved UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Catalog Number Socket 5 No. of Sockets Factory Phase Balancing NEMA Indoor Enclosure Ring Type Socket Factory Phase Balanced with Copper Bus NEMA 3R Outdoor Enclosure AB TMP8AB TMP8RAB AC TMP8AC TMP8RAC BC TMP8BC TMP8RBC AB TMP83AB TMP83RAB AC TMP83AC TMP83RAC BC TMP83BC TMP83RBC AB TMP84AB TMP84RAB AC TMP84AC TMP84RAC BC TMP84BC TMP84RBC AB TMP85AB TMP85RAB AC TMP85AC TMP85RAC BC TMP85BC TMP85RBC 0

11 Meter Stack Modules Residential Single Phase MEG Approved 800A Horizontal Bussing 5 & 00A Sockets 800 amp, 4 Wire Crossbus (Aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Meter Equipment Group Approved These MEG approved units have an added cotter pin that eliminates failure of the metering stabs when the meter is plugged into the meter base. Socket 5 00 No. of Sockets Ring Type Socket Ringless Type Socket (4 Jaw Socket Standard) Ringless Type Socket (4 Jaw Socket Standard) Horned Bypass Factory Installed TMP8RF TMPR8RF TMPR8RHBF 3 TMP83RF TMPR83RF TMPR83RHBF 4 TMP84RF TMPR84RF TMPR84RHBF 5 TMP85RF TMPR85RF 6 TMP86RF TMPR86RF TMPR86RF TMPR80RF 3 TMP830RF TMPR830RF 4 TMP840RF TMPR840RF TMPR840RHBF 5 TMPR850RF One snap-type, aluminum sealing ring (TSR5) per socket included Meter Stack Modules Residential Single Phase 00A Horizontal Bussing 5 & 00A Sockets 00 amp, 4 Wire Crossbus (aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Socket 5 00 No. of Sockets Ring Type Socket Catalog Number Ringless Type Socket (4 Jaw Socket Standard) Ringless Type Socket (4 Jaw Socket Standard) Horned Bypass Factory Installed TMPR TMPRR TMPRRHB 3 TMP3R TMPR3R TMPR3RHB 4 TMP4R TMPR4R TMPR4RHB 5 TMP5R TMPR5R TMPR5RHB 6 TMP6R TMPR6R TMPR6RHB TMP0R TMPR0R TMPR0RHB 3 TMP30R TMPR30R TMPR30RHB 4 TMP40R TMPR40R TMPR40RHB 5 TMP50R TMPR50R TMPR50RHB 5 TMP50R, TMPR50RBUS TMPR50RHBBUS One snap-type, aluminum sealing ring (TSR5) per socket included BUS suffix indicates change to centerline of horizontal bussing from 8.88" to 4.0" from bottom of unit

12 Meter Stack Modules Residential Single Phase MEG Approved 00A Horizontal Bussing 5 & 00A Sockets 00 amp, 4 Wire Crossbus (Aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Meter Equipment Group Approved Socket 5 00 No. of Sockets Ring Type Socket Ringless Type Socket (4 Jaw Socket Standard) Ringless Type Socket (4 Jaw Socket Standard) Horned Bypass Factory Installed 4 TMPR4RF TMPR4RHBF 5 TMPR5RF TMPR5RHBF 6 TMPR6RF 4 TMP40RF TMPR40RF TMPR40RHBF 5 TMPR50RF One snap-type, aluminum sealing ring (TSR5) per socket included

13 Tenant Main Breakers for PH Residential Meter Modules (800A & 00A Horizontal Bussing) Tenant Main Breakers for 5A, Pole Sockets 0kAIC kaic Wire Size 60 THQL60 THHQL60 () #8-#3 CU; #8-#3AL 70 THQL70 THHQL70 80 THQL80 THHQL80 90 THQL90 THHQL90 () #6-/0 CU; #4-#/0 AL 00 THQL00 THHQL00 () #-/0 CU; #-/0 AL 0 THQL0 THHQL0 5 THQL5 THHQL5 () #-/0 CU; #-/0 AL 5 TMQL5SSF Sub-Feed lug. No overcurrent protection. Tenant Main Breakers for 5A, Pole Sockets QL 4 kaic 60 TMQL60 Wire Size QA 65 kaic TMQA60 70 TMQL70 TMQA70 80 TMQL80 #8-# (Cu) or TMQA80 90 TMQL90 #8-/0 (Al) TMQA90 00 TMQL00 TMQA00 0 TMQA0 5 TMQL5 /0 - #4 TMQA5 Wire Size #8-/0 Tenant Main Breakers for 00A, Pole Sockets 0kAIC kaic Wire Size 00 TQD00 THQD00 5 TQD5 THQD5 50 TQD50 THQD50 75 TQD75 THQD75 00 TQD00 THQD00 () #-300 CU; #-300 AL Tenant Main Circuit Breakers for 00A, Pole Sockets QC 4 kaic QF 65 kaic QV 00 kaic 60 TMQC060MM TMQF060MM TMQV060MM 70 TMQC070MM TMQF070MM TMQV070MM 80 TMQC080MM TMQF080MM TMQV080MM 90 TMQC090MM TMQF090MM TMQV090MM 00 TMQC00MM TMQF00MM TMQV00MM 0 TMQC0MM TMQF0MM TMQV0MM 5 TMQC5MM TMQF5MM TMQV5MM 50 TMQC50MM TMQF50MM TMQV50MM 75 TMQC75MM TMQF75MM TMQV75MM 00 TMQC00MM TMQF00MM TMQV00MM For 60A-00A P breakers use TMQV5L to get 300MCM terminals. Wire Size #6-4/0 3

14 Meter Mod III Residential Meter Stacks Field Installed Accessories Steel Meter Socket Covers Fifth Jaw Kits Description Catalog No. Description Catalog No. Blank (fits bottom position only) Ringless (Field -converts ring-type to ringless) 5 Amp TMCBB 00 Amp TMCB0B 5 amp top socket for and 3 gang TMCRT 5 amp for all other sockets TMCR 00 amp for all sockets TMCR0 Bused; 3, 6, or 9 o'clock mounting Order two for fifth and sixth jaw. Not suitable for -gang ring type Isolated; 3 or 9 o'clock mounting TM5JA TM5JUA By-pass Kits Sealing Rings Description Manual Slider-Type (Ring Type Only) Catalog No. 5 amp top socket for, 3, 5 and 6 gang TMBPMTA 5 amp for all other sockets TMBPMA 00 amp for all sockets TMBPM0A Jumper Straps Type (use with TMCA) TMBPJ0 3 Description Material Catalog No. Screw Type Aluminum TSR Snap Type Stainless Steel TSR3 Screw and Lock Type Aluminum TSR4 Snap Type Aluminum (Standard) TSR5 Cover Includes Jumper Strap Type-fits all (Ring Type Only) TMBPC0 Horn-Type-fits all (Ringless Only) TMBPH0A 3 Miscellaneous Description Lexan Meter socket Cover Plate (without tabs) Lexan Meter Socket Cover Plate Equipment Ground Bar, (6) 6-/0 Individual Meter Socket Barrier Kit (includes 6) Mounting Z-Rail, 4-foot Spacer, 4-inch, 4 cross bus rated 00A Catalog No. TMCA TMCP TMEG TMBR TMZR TMPS Elbow, 6-inch x 6-inch, 4 cross bus rated 00A TMPE 4 Elbow, -inch x -inch, 4 cross bus rated 00A TMPEA 4 Anti-Inversion Clip Endwall Endwall TQD Breaker Mounting Kit. This is a replacement part. Units come with this part factory installed. Not UL Listed. 00 amps continuous amps continuous. 4 Indoor Type. TMIC TM34BEW00 TM56BEW00 TMTQD3 4

15 Meter Stack Modules Commercial Single-Phase 5A/400A Ringless Sockets w/ Lever Bypass Single-Phase/3 Wire 0/40 Vac or Three-Phase, 4 Wire, Horizontal Bus, 08Y/0 Vac System Voltage 00 amp, 4 Wire cross bus (aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Socket () 4- Equipment Ground Kit per Socket, Factory Installed Only 5A and 400A Ringless Type Meter Stacks contain Lever Bypass 5A and 00A Meter Sockets do not contain Lever Bypass Ringless Type Socket with Lever Bypass. All units are 7-terminal except TMPK. Socket 5 No. of Sockets Catalog Number TMPRR TMPRR 3 TMPR3R 4 TMPR4R TMPR40RB,3 Factory Installed Fifth Jaw (TM5JA Bused) Included 400 TMPR40RB,3 TMPK40RB TMPK40RBA One 400A tenant main breaker included. Two 400A tenant breakers included. 3 Main Breaker Modules Alternate Rating Plugs table for alternate 400A Rating Plugs 5

16 Tenant Main Breakers for PH Commercial Meter Stack Modules (00A Horizontal Bussing) Tenant Main Circuit Breakers for 5A, Pole Sockets 0kAIC Wire Size 5 TEB05 0 TEB00 5 TEB05 30 TEB TEB TEB TEB TEB TEB TEB TEB TEB TQD00 5 TQD5 50 TQD50 75 TQD75 00 TQD00 5 Use TMQV () #4-3 CU; #- AL () #6/0 CU; #4-/0 AL () #-300 CU; #-300 AL Tenant Main Circuit Breakers for 5A, Pole Sockets kaic Wire Size 00 THQD00 5 THQD5 50 THQD50 75 THQD75 00 THQD00 5 Use TMQV () #-300 CU; #-300 AL Tenant Main Circuit Breakers for 00A/5A, Pole Sockets QC 4 kaic QF 65 kaic QV 00 kaic 60 TMQC060MM TMQF060MM TMQV060MM 70 TMQC070MM TMQF070MM TMQV070MM 80 TMQC080MM TMQF080MM TMQV080MM 90 TMQC090MM TMQF090MM TMQV090MM 00 TMQC00MM TMQF00MM TMQV00MM 0 TMQC0MM TMQF0MM TMQV0MM 5 TMQC5MM TMQF5MM TMQV5MM 50 TMQC50MM TMQF50MM TMQV50MM 75 TMQC75MM TMQF75MM TMQV75MM 00 TMQC00MM TMQF00MM TMQV00MM 5 TMQC5MM TMQF5MM TMQV5MM For 60A-5A P breakers use TMQV5L to get 300MCM terminals. Wire Size #6-4/0 6

17 Meter Stack Modules Commercial Three-Phase, 5A/400A Ringless Sockets w/ Lever Bypass Three-Phase / 4 Wire, 40-0 Vac, Three-Phase / 4 Wire 08Y/0Vac 00 amp, 4 Wire cross bus (aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Socket () 4- Equipment Ground Kit per Socket, Factory Installed Swingaway Mounting Feet Factory Installed Only 5A and 400A Ringless Type Meter Sockets contain Lever Bypass 5A and 00A Meter Sockets do not contain Lever Bypass Ringless Type Socket with Lever Bypass. All units are 7-terminal except TMPK. Socket No. of Sockets Catalog Number Factory Installed Seventh Jaw (7 Terminal) TMPR3R 5 TMPR3R 3 TMPR33R 4 TMPR34R Included TMPR340TR TMPR340RB 400 TMPR340RB TMPK340RB TMPK340RBA Shipped from the factory as 7-jaw units (7 terminal.) 400 Amp tenant breaker included, 65 kaic 7

18 Tenant Main Breakers for 3PH Commercial Meter Stack Modules (00A Horizontal Bussing) Tenant Main Circuit Breakers for 00A/5A, 3 Pole Sockets 0kAIC Wire Size 5 TEB305 0 TEB300 5 TEB TEB TEB TEB TEB TEB TEB TEB TEB TEB3090 () #4-3 CU; #- AL () #6/0 CU; #4-/0 AL 00 TEB300 () #3-3/0 CU; #-3/0 AL 5 TQD35 50 TQD TQD TQD300 () #-300 CU; #-300 AL 5 Use TMQC Tenant Main Circuit Breakers for 00A/5A, 3 Pole Sockets kaic Wire Size 00 THQD300 5 THQD35 50 THQD350 () #-300 CU; #-300 AL 75 THQD THQD300 5 Use TMQC Tenant Main Circuit Breakers for 00A/5A, 3 Pole Sockets QC 4 kaic QF 65 kaic QV 00 kaic 60 TMQC3060 TMQF3060 TMQV TMQC3070 TMQF3070 TMQV TMQC3080 TMQF3080 TMQV TMQC3090 TMQF3090 TMQV TMQC300 TMQF300 TMQV300 0 TMQC30 TMQF30 TMQV30 5 TMQC35 TMQF35 TMQV35 50 TMQC350 TMQF350 TMQV TMQC375 TMQF375 TMQV TMQC300 TMQF300 TMQV300 5 TMQC35 TMQF35 TMQV35 For 60A-5A 3P breakers use TMQV5L3 to get 300MCM terminals. Wire Size #6-4/0 8

19 Meter Mod III Commercial Meter Stacks Field Installed Accessories Description TEB Breaker Mounting Kit Catalog No. TMTEB Barrel Lock Bracket and Guard Kit TMBL Bypass Kit, Totalizing Jumper Type TMBPT30, Replacement Phase Balancing Jumper Kit TMPJ3 Blank Meter Socket Cover, fits all positions Individual Meter Socket Barrier Kit, includes 6 Insulator for Lever By-Pass Handle Mounting Z Rail, 4-foot Spacer, 4-inch, 4 cross bus rated 00A TMCB3A TMBR3 TMHN TMZR TMPS Elbow, 6-inch x 6-inch, 4 cross bus rated 00A TMPE 3 Elbow, -inch x -inch, 4 cross bus rated 00A TMPEA 3 Not UL Listed. 80 amps continuous. 3 Indoor, Type, for inside corners only. Mini Mod III Ring-Type and Ringless UL Listed (Panelboards No. 67) Indoor/Outdoor construction Ring-Type and Ringless Meter Sockets Bondable Neutral, Strap included -inch Mounting Z Rail included Swing Away Mounting Feet factory installed Underground, incoming feed only Socket No. of Sockets Main Ampere Rating Ring-Type Socket 4 Ring-Type Socket (5 Jaw Socket Standard) Horned Bypass Factory Installed Ringless Type Socket Ringless Type Socket (5 Jaw Socket Standard) Horned Bypass Factory Installed Main Wire Size AWG/kcmil Cu/Al - Phase Service Ground Equipment Ground 00 TMMR 5 TMMRHB 5 TMMRR 5 TMMRRHB 5 () / TMM43R TMM43RHB TMMR43R TMMR43RHB TMM44R TMM44RHB TMMR44R TMMR44RHB TMM65R TMM65RHB TMMR65R TMMR65RHB TMM66R TMM66RHB TMMR66R TMMR66RHB () or () /0-50 () TMM40R TMMR40R TMMR40RHB 6-/ TMM630R TMM630RHB TMMR630R TMMR630RHB TMM640R TMM640RHB TMMR640R TMMR640RHB () TMM650R TMMR650R TMMR650RHB TMM660R TMMR660R TMMR660RHB 4 One snap-type, aluminum sealing ring (TSR5) per socket included 5 May be fed from overhead. Use hub TC300. 9

20 Mini Mod III Ring-Type and Ringless - MEG Approved 5A & 00A Sockets UL Listed (Panelboards No. 67) Indoor/Outdoor construction Ring-Type and Ringless Meter Sockets Bondable Neutral, Strap included -inch Mounting Z Rail included Swing Away Mounting Feet factory installed Underground, incoming feed only These MEG approved units have an added cotter pin that eliminates failure of the metering stabs when the meter is plugged into the meter base. Socket No. of Sockets Main Ampere Rating Ring-Type Socket Ringless Socket (5th Jaw Socket Standard) AWG/kcmil Cu/Al - Phase Service Ground 00 TMMRF TMMRRF () /0 Equipment Ground TMM43RF TMMR43RF () or TMM44RF TMMR44RF () / TMM65RF TMMR65RF TMM66RF TMMR66RF 400 Use TMM630R TMMR40RF TMM630RF TMMR630RF TMM640RF TMMR640RF Use Ringless or Meter Mod III TMMR650RF Use Ringless or Meter Mod III TMMR660RF One snap-type, aluminum sealing ring (TSR5) per socket included. May be fed from overhead. Use hub TC300. () () /

21 Tenant Main Breakers for Mini Mod Product Family Tenant Main Breakers for 5A, Pole Sockets 0kAIC kaic Wire Size 60 THQL60 THHQL60 () #8-#3 CU; #8-#3AL 70 THQL70 THHQL70 80 THQL80 THHQL80 () #6-/0 CU; #4-#/0 AL 90 THQL90 THHQL90 00 THQL00 THHQL00 () #-/0 CU; #-/0 AL 0 THQL0 THHQL0 5 THQL5 THHQL5 () #-/0 CU; #-/0 AL 5 TMQL5SSF Sub-Feed lug. No overcurrent protection. Tenant Main Breakers for 5A, Pole Sockets QL 4 kaic 60 TMQL60 Wire Size QA 65 kaic TMQA60 70 TMQL70 TMQA70 80 TMQL80 #8-# (Cu) or TMQA80 90 TMQL90 #8-/0 (Al) TMQA90 00 TMQL00 TMQA00 0 TMQA0 5 TMQL5 /0 - #4 TMQA5 Wire Size #8-/0 Tenant Main Breakers for 00A, Pole Sockets 0kAIC kaic Wire Size 00 TQD00 THQD00 5 TQD5 THQD5 50 TQD50 THQD50 75 TQD75 THQD75 00 TQD00 THQD00 () #-300 CU; #-300 AL Tenant Main Circuit Breakers for 00A, Pole Sockets QC 4 kaic QF 65 kaic QV 00 kaic 60 TMQC060MM TMQF060MM TMQV060MM 70 TMQC070MM TMQF070MM TMQV070MM 80 TMQC080MM TMQF080MM TMQV080MM 90 TMQC090MM TMQF090MM TMQV090MM 00 TMQC00MM TMQF00MM TMQV00MM 0 TMQC0MM TMQF0MM TMQV0MM 5 TMQC5MM TMQF5MM TMQV5MM 50 TMQC50MM TMQF50MM TMQV50MM 75 TMQC75MM TMQF75MM TMQV75MM 00 TMQC00MM TMQF00MM TMQV00MM For 60A-00A P breakers use TMQV5L to get 300MCM terminals. Wire Size #6-4/0

22 Mini Mod III Field Installed Accessories By-pass Kits Semi-Flush Kits Description Manual Slider-Type (Ring Type Only) Catalog No. 5 amp top socket for, 3, 5 and 6 gang TMBPMTA 5 amp for all other sockets TMBPMA 00 amp for all sockets TMBPM0A Jumper Straps Type (use with TMCA) TMBPJ0 4 Cover Includes Jumper Strap Type-fits all (Ring Type Only) 3 TMBPC0 4 Horn-Type-fits all (Ringless Only) TMBPH0A Description 5A Sockets 00A Sockets Catalog No. gang TMMSF 3 and 4 gang TMMSF4 5 and 6 gang TMMSF6 gang TMM0SF 3 and 4 gang TMM0SF4 5 and 6 gang TMM0SF6 Compression Lug Landing Kit Description Catalog No. 600 amp TMM6CLL Includes 3 pads each with threaded stud connections (and hardware) for compression or mechanical lugs with NEMA -hole bolt configuration (lugs not furnished). Not suitable for -gang. Fifth Jaw Kits Description Bussed; 3, 6, or 9 o'clock mounting Order two for fifth and sixth jaw. Not suitable for -gang ring type Isolated; 3 or 9 o'clock mounting Catalog No. TM5JA TM5JUA Steel Meter Socket Covers Sealing Rings Description Blank (fits bottom position only) Ringless (Field -converts ring-type to ringless) Catalog No. 5 Amp TMCBB 00 Amp TMCB0B 5 amp top socket for and 3 gang TMCRT 5 amp for all other sockets TMCR 00 amp for all sockets TMCR0 Description Material Catalog No. Screw Type Aluminum TSR Snap Type Stainless Steel TSR3 Screw and Lock Type Aluminum TSR4 Snap Type Aluminum (Standard) TSR5 Miscellaneous Description Lexan Meter socket Cover Plate (without tabs) Lexan Meter Socket Cover Plate Equipment Ground Bar, (6) 6-/0 Individual Meter Socket Barrier Kit (includes 6) Mounting Z-Rail, 4-foot Lug Kit for (3) 4/0 cable 00 amps continuous. For top socket on TMM40R, order TMBPM0TA amps continuous. 4 Not UL Listed. Catalog No. TMCA TMCP TMEG TMBR TMZR TMPAL40

23 3

24 Other Publications and References Refer to these publications and resources for additional information about our products: Pub No. DET-008 DET-388 DET-395 DET-838 DET-843 DET-848 DET-860 Title UL Component Recognized Series-Connected Ratings Renewal Parts Construction and Details Residential Electronic Circuit Interrupters Houses to High Rises Modular Metering Application Guide Modular Metering Application Guide: Mini Mod III Product Family Visit our website: for links to the above publications and additional information such as time current curves, outline and dimensional drawings, installation instructions, application and technical information. For questions about any of our modular metering products, please us at GE 4 Woodford Avenue Plainville, CT *Indicates a trademark of the General Electric Company and/or its affiliates. Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. 08, General Electric Company and/or its affiliates. All rights reserved. 6.8 DET856E

Modular Metering Application Guide

Modular Metering Application Guide GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III

More information

Modular Metering Application Guide. Meter Mod * III Product Family

Modular Metering Application Guide. Meter Mod * III Product Family Modular Metering Application Guide Meter Mod * III Product Family Table of Contents Page No. Selection Guidelines and Nomenclature 3 UL Standard Listing and File Numbers for Meter Mod III Product Family

More information

Modular Metering Construction Details

Modular Metering Construction Details GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single

More information

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering for GE Meter Mod * III Modular Metering Your guide to GE s GE tenant main circuit breakers are typically used in residential and light commercial group metering applications. This product category offers

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

Modular Metering Section 2

Modular Metering Section 2 Mini Mod III Nomenclature...-3 Photos...-4 Ring -Type and Ringless...-5 Ring -Type and Ringless - MG pproved 5 & 00 Sockets...-6 Tenant Main reakers for Mini Mod Product Family...-7 Factory Installed Lug

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Meter Centers & Loadcenters Group Metering

Meter Centers & Loadcenters Group Metering June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through

More information

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection .11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Power Mod. Introduction.

Power Mod. Introduction. Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination

More information

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .11 Metering Products Systems for Residential and Commercial Application Systems for Residential and Commercial Applications Product Description Group metering is a service entrance product line that consists

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

THQL1120AF2 THQL1120AF2 Arc Fault BRKR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering GE Energy onnections Single Socket and Horizontal etering EP pproved Single Socket etering EP pproved pplication Information GE s Single Socket etering products are designed for residential use. They are

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

POWER PRODUCT Meter Centres Contents

POWER PRODUCT Meter Centres Contents POWER PRODUCT Meter Centres Contents General Specifications - Catalogue Numbering System - 40V Meter Centre Overview - Features & Benefits -3 Procedure -5 Switches and Tap Boxes -6 Meter Stacks -7 Socket

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant

More information

Small Project Product Selection Guide

Small Project Product Selection Guide Small Project Product Selection Guide At your GE Distributor today! Panelboards Transformers Safety Switches NEMA Combo Starters Lighting Contactors imagination at work Small Projects Same Day When you

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

Section 1. Load Centers and Circuit Breakers.  Section Updated 11 / 2014 Section Updated 11 / 2014 Q-Line Circuit Breakers Product Features and Benefits...1-2 PowerMark Gold Load Centers Product Features and Benefits...1-3 PowerMark Gold and Plus Load Centers Product Number

More information

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module

More information

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

Typical AD Panelboard

Typical AD Panelboard Typical AD Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from supplier.

More information

5.11. Metering Products. Contents Description Systems for Residential and Commercial

5.11. Metering Products. Contents Description Systems for Residential and Commercial 3MM, 37MM, 3SS and 37SS Main Tenant ircuit reakers V2/EHD2100 ontents Description Systems for Residential and ommercial pplications............................ Meter Packs.............................

More information

No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together Recognized by UL and cul STATES Type have

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

REC Municipal Meter Mounting Equipment

REC Municipal Meter Mounting Equipment REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

SAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)

SAFETY SOCKET BOX. Note 8 3 MIN. 3 Max. (200 A) .&. SAFETY SOCKET BOX USE: 1 12/24V 1A & 2A 4 Terminal EUSERC Dwg. No's 34 & 35 (With Factory Installed Test-Bypass Facilities) Refer to SR-452 for the complete Front View Lower-Panel Removed Note 3 3"

More information

Typical ADP Panelboard

Typical ADP Panelboard Typical ADP Panelboard 400/600/800A Installation Consult instructions NEMA PB-1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual

More information

Typical AE Panelboard

Typical AE Panelboard Typical AE Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from supplier.

More information

Typical AQ/AL Panelboard

Typical AQ/AL Panelboard Typical AQ/AL Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Evolution Series Switchboards

Evolution Series Switchboards GE Energy Evolution Series Switchboards Quick Reference imagination at work Main Lug Main Device Width (W) Switchboard Frame Neutral Bus Width (W) Switchboard Frame Neutral Bus Cover 3 A Ground Bar 10

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

Typical AE Panelboard

Typical AE Panelboard Typical AE Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from supplier.

More information

Typical AEP Panelboard

Typical AEP Panelboard Typical AEP Panelboard 400/600/800A Installation Consult instructions NEMA PB-1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

Metering NEED. Meter Sockets. Product Description

Metering NEED. Meter Sockets. Product Description Meter Sockets Meter Sockets Single Position (Ring, Ringless and Bypass)........ - Multiple Position Without Tenant Main Breakers.......... - Accessories.......................... -7 Meter Packs (All-in-Ones)

More information

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection... .5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,

More information

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive

More information

Indianapolis Power & Light Company

Indianapolis Power & Light Company Indianapolis Power & Light Company Electric Service and Meter Manual The Electric Service & Meter Manual is not copyrighted and permission is hereby given to reproduce this document. However, the Indianapolis

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Section 6 Electric Metering: Residential

Section 6 Electric Metering: Residential Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work GE Energy Industrial Solutions EV Charging Station Application Guide imagination at work EV Charging Station Introduction The GE EV Charging Station offers Level II charging capable of reducing charge

More information

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary.

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary. GE Industrial Solutions EntellEon * Low-Voltage Power Panel Simple. Responsive. Revolutionary. Introducing EntellEon A More Versatile Alternative to Traditional Power Panels EntellEon, the new low-voltage

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

GE Consumer & Industrial

GE Consumer & Industrial GE stock list for connector kits and replacement breakers (most common) Breaker Mounting Hardware for Spectra bolt-on and Jiffy (includes hardware, brackets and filler plate) AMCB4EYFP AMCB6EYFP AMCB6EBFP

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

High barriers Recognized by UL and cul Self-extinguishing materials Nonferrous material Corrosion-resistant nickel finish Safety-grip handle A complete line of switches is available for meter, relay, instrument,

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

American Electric Supply, Inc.

American Electric Supply, Inc. American Electric Supply, Inc. 6 S. Maple Street Date: 0/8/204 Corona, CA 92880 Telephone: 95-80-4665 Email: bmcdonald@amelect.com Fax: 95-552-626 Speedi Version: V 0.6 Valued Customer, Bill of Material

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

EZ Meter-Pak Meter Centers

EZ Meter-Pak Meter Centers NEMA 3 onstruction Vac Maximum, for use on A systems, suitable for use as ervice Equipment. tility ompany equirements: eview local utility requirements to ensure that metering equipment meets their standards.

More information

Lighting Panelboards. P2 Panelboards

Lighting Panelboards. P2 Panelboards Lighting Panelboards P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled options to meet virtually any lighting panel application. The

More information

10. METERING General Requirements

10. METERING General Requirements 10. METERING 10.1 General Requirements A. The Company will not supply service to a Customer whose wiring is designed for resale of electricity through submetering except for recreational campgrounds, marinas,

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

Power Mod. Type WMM Residential Meter Stacks. Revised 06/01/13. Residential Meter Stacks

Power Mod. Type WMM Residential Meter Stacks. Revised 06/01/13. Residential Meter Stacks Type WMM Residential Meter Stacks 06/01/13 Residential Meter Stacks Power Mod s core offering of Residential Meter Stacks, type WMM, offers the widest product offering and flexibility in the industry.

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

SECTION VII METERING INSTALLATIONS

SECTION VII METERING INSTALLATIONS SECTION VII METERING INSTALLATIONS 1. GENERAL Outdoor metering is required for all new service installations to one, two, and three family detached, semi-detached and row houses. 2. COMPANY FURNISHES AND

More information

Proline Panelboard and breakers

Proline Panelboard and breakers Proline Panelboard and breakers ProLine & breakers ProLine The ProLine is the electrical industry's first limiting, touch safe, fully coordinated UL 67. Electrical: UL File #E319800 UL67 225A and 400A

More information

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial

More information

Meter Centers Meter Mounting Devices

Meter Centers Meter Mounting Devices Meter Mounting Devices General General Information Materials: 16 gauge, galvanized steel, G-90 Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information