Modular Metering Application Guide. Meter Mod * III Product Family

Size: px
Start display at page:

Download "Modular Metering Application Guide. Meter Mod * III Product Family"

Transcription

1 Modular Metering Application Guide Meter Mod * III Product Family

2 Table of Contents Page No. Selection Guidelines and Nomenclature 3 UL Standard Listing and File Numbers for Meter Mod III Product Family 4 Main Breaker Module, Single-Phase, 3 Wire, 0/40 Vac 5 Main Breaker Module, Single-Phase, 3 Wire, 0/40 Vac with Arc Reduction Means 6 Main Breaker Module, Three-Phase, 4 Wire, 08Y/0 Vac or Three-Phase, 4 Wire, 0/40V Delta Hi-Leg 7 Main Breaker Module, Three-Phase, 4 Wire, 08Y/0 Vac or Three-Phase, 4 Wire, 0/40V Delta Hi-Leg with Arc Reduction Means 8 Main Breaker Module with Integral Pull Box (Single and Three-Phase) - EUSERC Unit 9 Main Breaker Module Accessories: Alternate Rating Plugs and Shunt Trips 9 Main Breaker Module: Lug Kits 0 Main Fusible Switch Module, Single-Phase, 3 Wire 0/40 Vac Main Fusible Switch Module, Three-Phase, 4 Wire 08Y/0 Vac Main Fusible Switch Module with Integral Pull Box (Single-Phase and Three-Phase) - EUSERC Unit 3 Main Fusible Switch Modules Fuses and Compression Lugs 3 Main Fusible Switch Modules: Lug Kits 4 Main Lug Module Single-Phase, 3 Wire 0/40 Vac 5 Main Lug Module Three-Phase, 4 Wire 08Y/0 Vac 6 Main Lug with Feed Through, Three Phase, Four Wire / Single Phase, Three Wire 0/40 Vac, 08Y/0 Vac 6 Main Lug Module and Main Lug with Feed Through Module: Lug Kits 7 Main Pull Box Module, Single-Phase, 3 Wire 0/40 Vac 8 Main Pull Box Module, Three-Phase, 4 Wire 08Y/0 Vac 9 Meter Stack Modules, Residential Oveview 0 Meter Stack Modules, Residential, Single-Phase, 800 Amp Horizontal Bussing, 5 & 00A Sockets ConEd Approved Meter Stack Modules, Residential, Single-Phase, 800 Amp Horizontal Bussing, 5 & 00A Sockets - MEG Approved Meter Stack Modules, Residential, Single-Phase, 00 Amp Horizontal Bussing, 5 & 00A Sockets 3 Meter Stack Modules, Residential, Single-Phase, 00 Amp Horizontal Bussing, 5 & 00A Sockets - MEG Approved 4 Tenant Main Breakers for PH Residential Meter Modules (800A & 00A Horizontal Bussing) 5 Meter Stack Modules, Commercial Overview 6 Meter Stack Modules, Commercial, Single-Phase, 5A/400A Ringless Sockets w/lever Bypass 7 Meter Stack Modules, Commercial, Single-Phase, 00A Ring Sockets w/ Test Bypass Kits EUSERC 7 Tenant Main Breakers for PH Commercial Meter Stack Modules (00A Horizontal Bussing) 8 Meter Stack Modules, Commercial, Three-Phase, 5A/400A Ringless Sockets w/ Lever Bypass 9 Meter Stack Modules, Commercial, Three-Phase, 00A Ring Sockets w/ Test Bypass Kits EUSERC 9 Tenant Main Breakers for 3PH Commercial Meter Stack Modules (00A Horizontal Bussing) 30 Center-Feed for the Main Module 3 Modular Metering System Short Circuit Rating UL Listed 3 Meter Mod III Main Breaker to Tenant Breaker Series Ratings 5A Sockets 3 Meter Mod III Main Breaker to Tenant Breaker Series Ratings 00A Sockets 34 Dimensions 36 Accessories 40 Other Publications and References 40

3 Main Device Selection Guidelines. Main Module - Select only one See page Single Phase Three Phase Main Breaker 5. Select Main Ampere Rating 3. Select Short Circuit Rating 4. How many meter stacks are needed? Residential: 5. Select the Breakers that go into meter stacks Main Breaker w/ Integral Pull Box 9 800A or 00A Bus 400 Main Fusible Switch 600 Socket Amps: 0,000 See Main Breaker Main Fusible Switch w/ Integral Pull Box A or 00A,000 Selections: 000 Ring or Ringless Main Lug 5 4,000 PH Tenant Page 5 00 Main Breaker 7 65,000 Commercial: PH Commercial Page Main Breaker w/ Integral Pull Box 9 00,000 All 00A Bus 3PH Commercial Page Main Fusible Switch Socket Amps: 000 Main Fusible Switch w/ Integral Pull Box 3 00A,5A or 400A Main Lug 6 Ring or Ringless 6. Accessories Various options. See BuyLog for details. Main Nomenclature GE Identification Type MP = Meter Mod III Insert for 3-Phase T MP 3 SB 8 R Type SB = Main Breaker, Top/Bottom Feed (400-00A) SHB = Main Breaker, High Interrupting, Top/Bottom Feed (400-00A) BB = Main Breaker, Bottom Feed ( A) BT = Main Breaker, Top Feed ( A) BU = Main Breaker with Integral Pull Box - EUSERC FT = Main Switch, Top Feed FB = Main Switch, Bottom Feed L = Main Lug U = Main Pull Box AR Enclosures R = Type 3R Rainproof CLL = Compression Lug Landing Kit Included ST = Shunt Trip, Factory Installed Maximum Ampere Rating 4 = 400A 6 = 600A 8 = 800A 0 = 000A = 00A 4 = 400A 6 = 600A 0 = 000A Additional Features AR = Arc Reduction CRIS = Copper, Riser Meter Stack Nomenclature GE Identification Type MP = Meter Mod Ring Type MPR = Meter Mod Ringless MPK = Meter Mod K-Base Socket Insert for 3-Phase Horizontal Bus Rating 8 = 800A = 00A T MP T R F Socket Rating = 5A 0 = 00A = 5A 40 = 400A Socket Positions -6 Special MEG Approved Enclosures R = Type 3R Rainproof Insert for Tenant Breaker 3

4 UL Standard Listing and File Numbers Modular Metering Equipment UL Standard for Safety UL File No. Meter Modules No. 67 Panelboards E874 Main Modules Breaker No. 489 Molded Case Circuit Breakers E73 Switch No. 98 Enclosed Switches E9565 Lug No. 67 Panelboards E874 Pull Box No. 869 Service Equipment E8470 Tenant Main Breakers THQL, TQD No. 489 Molded Case Circuit Breakers E59 THHQL, THQD No. 489 Molded Case Circuit Breakers E59 TMQL, TMQV No. 489 Molded Case Circuit Breakers E73 Accessories Meter No. 44 Meter Sockets E874 Other No. 67 Panelboards E874 Short Circuit Interrupting Ratings These panelboards have a maximum short circuit current rating of 00,000 RMS symmetrical amperes, 40 volts AC maximum. The actual rating depends on the branch breakers and the main breaker, if any, installed in or ahead of the panelboard. The correct combinations for various short circuit ratings follow. Any additional or replacement breakers must be a General Electric type, as indicated, with equal or greater interrupting capacity. Maximum Short Circuit Rating, rms Symmetrical Amperes, 40 Vac or 0/40 Vac Main Circuit Breaker When the breaker protecting the panelboard, separate or integral, is GE Type Branch Circuit Breaker And when the branch circuit breakers installed are GE Type 0,000 None, THQL, TQMV, SKH, SGD, SGH, SGL THQP, THQL, THQLGFT, TQD, THHQL, THQD, TMQL, TMQV,000 None, THHQL, THQMV, SKH, (300-00A), SGD, SGH (5-600A) THQP, THQL, THQLGFT, TQD, THHQL, THQD, TMQL, TMQV 4,000 TMQB, TMQL, 300V Class T Fuse (600A max.) 65,000 SGD, SGH (5-600A) 00,000 TMQV, SGL (5-600A) 00, V Class T Fuse (400A max.) 5-30A only. 3 Suitable as branch breaker when tenant main provided is: THQL, THHQL, TMQL, TQD, TMQV A, -pole only A, - and 3-pole only. THQP3, THQL, THQLGFT, TQD, THHQL, THQD, TMQL, TMQV THQL, THHQL, TQD, THQD, TMQB, TMQL, TMQV THQP 3, THQL, THQLGFT, TQD 4, THHQL, THQD 4, TMQL, TMQV THQP 3, THQL, THHQL, TQD 5, THQD 5, TMQL, TMQV 4

5 Bonding strap Use this strap for bonding the enclosure to neutral when required Service ground lugs () Flat bus cap Rain Cover 6 gauge Horizontal bus Tin-plated aluminum with captive hardware Deep bus cap Neutral lugs Pole main circuit breaker Rating plug Incoming lugs (included) Top or bottom feed Main Breaker Module, Single-Phase, 3 Wire 0/40 Vac Breaker included. 80% Rated MCB Single-phase mains have a neutral, A-phase, B-phase and ground and may be connected to three-phase horizontal bus stacks. However, output is only single-phase. All mains are required to be center feed only when main breaker is greater than horizontal bus amps Catalog Number Main Ampere Rating IC Rating Max kaic TMPSB4R TMPSHB4R 00 TMPSB6R TMPSHB6R 00 Feed Location 0-40Vac Shunt Trip Main Breaker Frame Bottom No SGH400 Bottom No SGH600 Main Wire Size AWG/kcmil Cu/Al - Phase Al: () /0-500 or () Cu: /0-400 or () Al: () /0-500 or () Cu: /0-400 or () Main Wire Size AWG/kcmil Cu/Al - Neutral () -600 () -600 TMPSB8R Bottom No SKH800 Al/Cu (3) 3/0-500 (4) TMPSB0R Bottom No SKH00 Al: (4) Cu: (4) 50/350 (4) TMPSBR Bottom No SKH00 Al: (4) Cu: (4) 50/350 (4) TMPBB4R Bottom No RG (4) kcmil (4) TMPBB6R 3 Bottom TMPBB6RST 3 Bottom Yes TMPBT6R 3 Top No TMPBT6RST 3 Top Yes TMPBT0R TMPBB0R 3 Top Bottom No RG Al/Cu (4) kcmil Al/Cu (4) No RG (6) # 600 kcmil (6) # 600 kcmil Optional lug TCAL4 field installed wire range (3) kcmil. Optional neutral lug field installed wire range (3) /0-750 kcmil. Lug kit part number TMPL Fixed Rating Plug not Field adjustable. 4 To meet NEC 04 Arc Energy Reduction (Section 40.87), please use a 75A rating plug. Product number SPRK00A75, order separately 5

6 Bonding strap Use this strap for bonding the enclosure to neutral when required Service ground lugs () Flat bus cap Rain Cover 6 gauge Horizontal bus Tin-plated aluminum with captive hardware Deep bus cap Neutral lugs Pole main circuit breaker with arc reduction means Rating plug Incoming lugs (included) Top or bottom feed Main Breaker Module, Single-Phase, 3 Wire 0/40 Vac with Arc Reduction Means Breaker included. 80% Rated MCB Single-phase mains have a neutral, A-phase, B-phase and ground and may be connected to three-phase horizontal bus stacks. However, output is only single-phase. All mains are required to be center feed only when main breaker is greater than horizontal bus amps Amperage Phase IC Rating Max kaic Feed Catalog Number Description Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral 400A to Less Than 00A Top or Bottom Use Standard Part #. Code effects only 00A and greater 00A 00 Bottom TMPBBRAR 400A 00 Bottom TMPBB4RAR 00A Ph Main Breaker Bottom Feed - Arc Reduction 400A Ph Main Breaker Bottom Feed - Arc Reduction (4) (4) (4) (4) A 00 Bottom Top TMPBB6RAR TMPBT6RAR 600A Ph Main Breaker Bottom Feed - Arc Reduction 600A Ph Main Breaker Top Feed - Arc Reduction (4) (4) A 00 Bottom TMPBB0RAR 000A Ph Main Breaker Bottom Feed - Arc Reduction (6) #-600 (6) #-600 NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs but have factory installed trip units. If you need a trip setting that is different than the frame, please your GE sales rep at time of order entry and they will work with the factory to manually change this. For example, if you want a TMP3BB6RAR (600A frame) with 00A trip. 6

7 Bonding strap Use this strap for bonding the enclosure to neutral when required Service ground lugs () Flat bus cap Rain Cover 6 gauge Horizontal bus Tin-plated aluminum with captive hardware Deep bus cap 3 Pole main circuit breaker Neutral lugs Rating plug Incoming lugs (included) Main Breaker Module, Three-Phase, 4 Wire 08Y/0 Vac or Three-Phase, 4 Wire, 0/40V Delta Hi-Leg Breaker included. 80% Rated MCB. All mains are required to be center feed only when main breaker is greater than horizontal bus amps Catalog Number Main Ampere Rating IC Rating Max kaic TMP3SB4R TMP3SHB4R 00 TMP3SB6R TMP3SHB6R 00 Feed Location 0-40 Vac Shunt Trip Main Breaker Frame Bottom No SGH400 Bottom No SGH600 Main Wire Size AWG/ kcmil Cu/Al -Phase Al: () /0-500 or () Cu: /0-400 or () Al: () /0-500 or () Cu: /0-400 or () Main Wire Size AWG/kcmil Cu/Al - Neutral () -600 () -600 TMP3SB8R Bottom No SGH800 Al/Cu (3) 3/0-500 (4) TMP3SB0R Bottom No SGH00 TMP3SBR Bottom No SKH00 TMP3BB4R TMP3BT4R 3 TMP3BB6R Bottom Top Al: (4) Cu: (4) 50/350 (4) Al: (4) Cu: (4) 50/350 (4) No RG (4) kcmil (4) No RG Al/Cu (4) Al/Cu (4) TMP3BB6RCLL 3 Bottom No RG Compression Lugs Compression Lugs TMP3BB6RST 3 TMP3BT6R 3 TMP3BT6RST 3 TMP3BT0R 3 TMP3BB0R 3 Top Top Bottom Yes No Yes No RG Al/Cu (4) Al/Cu (4) RG (6) # 600 kcmil (6) # 600 kcmil TMP3BB0RCLL Bottom RG Compression Lugs Compression Lugs TMP3BT0RST 3 TMP3BB0RST 3 Top Bottom Yes RG (6) # 600 kcmil (6) # 600 kcmil Optional lug TCAL4 field installed wire range (3) kcmil. Optional neutral lug field installed wire range (3) /0-750 kcmil. Lug kit part number TMPL Fixed Rating Plug not Field adjustable. 4 To meet NEC 04 Arc Energy Reduction (Section 40.87), please use a 75A rating plug. Product number SPRK00A75, order separately 7

8 Bonding strap Use this strap for bonding the enclosure to neutral when required Service ground lugs () Flat bus cap Rain Cover 6 gauge Horizontal bus Tin-plated aluminum with captive hardware Deep bus cap 3 Pole main circuit breaker with arc reduction means Neutral lugs Rating plug Incoming lugs (included) Main Breaker Module, Three-Phase, 4 Wire 08Y/0 Vac or Three-Phase, 4 Wire, 0/40V Delta Hi-Leg with Arc Reduction Means Breaker included. 80% Rated MCB. All mains are required to be center feed only when main breaker is greater than horizontal bus amps The main breaker in this section has an arc reduction means that satisfies the requirement of NEC 04 Section Amperage Phase IC Rating Max kaic Feed Catalog Number Description Main Wire Size AWG/kcmil CU/AL - Phase Main Wire Size AWG/kcmil CU/AL - Neutral 400A to Less Than 00A 3 Top or Bottom Use Standard Part #. Code effects only 00A and greater 00A 3 00 Bottom Top TMP3BBRAR TMP3BTRAR 00A 3Ph Main Breaker Bottom Feed - Arc Reduction 00A 3Ph Main Breaker Top Feed - Arc Reduction (4) (4) A 3 00 Bottom Top TMP3BB4RAR TMP3BT4RAR 400A 3Ph Main Breaker Bottom Feed - Arc Reduction 400A 3Ph Main Breaker Top Feed - Arc Reduction (4) (4) A 3 00 Bottom Top TMP3BB6RAR TMP3BT6RAR 600A 3Ph Main Breaker Bottom Feed - Arc Reduction 600A 3Ph Main Breaker Top Feed - Arc Reduction (4) (4) A 3 00 Bottom Top TMP3BB0RAR TMP3BT0RAR 000A 3Ph Main Breaker Bottom Feed - Arc Reduction 000A 3Ph Main Breaker Top Feed - Arc Reduction (6) #-600 (6) #-600 NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs but have factory installed trip units. If you need a trip setting that is different than the frame, please contact your GE sales rep at time of order entry and they will work with the factory to manually change this. For example, if you want a TMP3BB6RAR (600A frame) with 00A trip 8

9 Main Breaker Module with Integral Pull Box (Single and Three-Phase) - EUSERC Unit For EUSERC applications please check with local utility requirements to make sure the pull box meets their dimensional requirements. Some applications may require you to use a Commercial Metering Switchboard. Main Breaker Module with Integral Pull Box Single-Phase- EUSERC Unit Catalog Number Main Amperage TMPBU4R 400 TMPBU6R 600 TMPBU8R 800 TMPBU0R 000 TMPBUR 00 IC Rating Feed Location 65 Top / Bottom Main Frame Type SGH SKH Line/Main Lug Size Landing pads with /" bolts per EUSERC drawing number 347 provided. Contractor will need to supply crimp/compression lugs. Line/Main Neutral Size Landing Pads Only Landing Pads Only Main Breaker Module with Integral Pull Box Three-Phase - EUSERC Unit Catalog Number Main Amperage TMP3BU4R 400 TMP3BU6R 600 TMP3BU8R 800 TMP3BU0R 000 TMP3BUR 00 IC Rating Feed Location 65 Top / Bottom Main Frame Type SGH SKH Line/Main Lug Size Landing pads with /" bolts per EUSERC drawing number 347 provided. Contractor will need to supply crimp/compression lugs. Line/Main Neutral Size Landing Pads Only Landing Pads Only Main Breaker Module Accessories Main Breaker Modules Alternate Rating Plugs Field installed Breaker Frame Rating (Amps) Trip Rating (Amps) Rating Plug Part No. 400A 600A 800A 00 5 SRPG400A5 50 SRPG400A SRPG400A SRPG400A SRPG600A SRPG600A SRPG600A SRPG600A SRPG600A SRPG600A SRPK800A SRPK800A SRPK800A SRPK800A SRPK800A SRPK00A SRPK00A SRPK00A SRPK00A SRPK00A SRPK00A75 Shunt Trip Field Installed For use on all Main Breaker Modules Shunt Trip Catalog Number 0 Vac SAST 40 Vac SAST 9

10 Main Breaker Modules, Single-Phase and Three-Phase Factory Installed Lug Kits Amp Rating Main Breaker Catalog No. Phase Wire Size Neutral Wire Size Lugs per Kit Total Lugs per Device TMPSB4R TMPSHB4R TMP3SB4R TMP3SHB4R TMPSB6R TMPSHB6R TMP3SB6R TMP3SHB6R TMPSB8R TMP3SB8R TMPSB0R TMP3SB0R TMPSBR TMP3SBR TMPBB4R, TMPBB4RAR TMP3BB4R, TMP3BB4RAR TMP3BT4R, TMP3BT4RAR TMPBB6R, TMPBB6RAR TMPBB6RST TMPBT6R, TMPBT6RAR TMPBT6RST TMP3BBT6RST TMP3BB6R, TMP3BB6RAR TMP3BT6R, TMP3BT6RAR TMP3BT6RST TMPBB0R, TMPBB0RAR TMPBT0R TMP3BB0R, TMP3BB0RAR TMP3BT0R, TMP3BT0RAR TCLK65 AL/CU: () /0-500 or AL/CU: () -600 () TCLK365 3 TCLK65 AL/CU: () /0-500 or AL/CU: () -600 () TCLK365 3 TCAL8 AL/CU: (3) 3/0-500 AL/CU: (4) TCAL5 AL: (4) AL/CU: (4) TCAL5 AL: (4) AL/CU: (4) TMPL600RD AL/CU: (4) AL/CU: (4) TMPL600RD AL/CU: (4) AL/CU: (4) lug/kit, 4 holes/lug lug/kit, 4 holes/lug TMPL000RD AL/CU: (6) #-600 AL/CU: (6) # Lug kits TCALK8 (for TMPSB8R) and TCALK38 (TMP3SB8R) can also be used instead of the TCAL8 lugs Lug kits TCALK5 (for TMPSB0R and TMPSBR) and TCALK35 (for TMP3SB0R and TMP3SBR) can also be used instead of TCAL5 lug lugs/device; 3 lugs/neutral 9 lugs/device; 3 lugs/neutral Optional Lug Kit Amp Rating Main Breaker Phase Catalog No. Phase Wire Size Lugs per Kit Neutral Catalog No. Neutral Wire Size 000 TMPSB0R TCAL4 3 AL/CU: (3) TMP3SB0R 3 00 TMPSBR TCAL4 3 AL/CU: (3) TMP3SBR 3 TMPBB4R 400 TMP3BB4R TMP3BT4R TMPL000RD (6) # TMBP000N (6) #-600 TMPBB6R 600 TMP3BB6R TMPBB6RST TMP3BB6RST TMPBT6R TMP3BT6R TMPBT6RST TMP3BT6RST TMPL000RD (6) # TMBP000N (6) # Lug kits TCALK4 (for TMPSB0R and TMPSBR) and TCALK34 (for TMP3SB0R and TMP3SBR) can also be used instead of TCAL4 lugs 0

11 Bonding strap Use this strap for bonding the enclosure to neutral when required Rain Cover 6 gauge Load T-fuse connection () Flat bus Service ground lugs Neutral Deep bus cap Switch handle Switch blades Knockouts Incoming lugs Main Fusible Switch Module, Single-Phase, 3 Wire 0/40 Vac Single-phase mains have a neutral, A-phase, B-phase group and may be connected to three-phase horizontal bus stacks. However, output is only single-phase All mains are required to be center feed only when the main fusible switch rating is greater than the horizontal bus amperage rating Catalog Number Main Ampere Rating TMPFT4R 400 IC Rating (Max) kaic Wire Entry Main Wire Size AWG/kcmil Cu/Al -Phase () /0-750 or () /0-300 Main Wire Size AWG/kcmil Cu/Al - Neutral () /0-750 or () /0-300 TMPFT6R 600 () -600 () -600 TMPFT8R Top (4) 3/0-750 (4) 3/0-750 TMPFTR TMPFTRST 00 (4) -500 (4) -500 () /0-750 or () /0-750 or TMPFB4R 400 () /0-300 () / Bottom TMPFB6R 600 () -600 () -600 TMPFB8R 800 (4) 3/0-750 (4) 3/0-750 Stud Sets per Phase and Neutral Fuse Not Included. Order Separately. Compression Lug Landing Kit Class T only Order Separately Class L only. Bolted Pressure Switch Class T only Order Separately TMPFBRT Bottom (4) -500 (4) -500 TMPFBRST see footnote TMPFBR see footnote TMPFBRT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMPFBR, but is significantly less expensive. TMP3FBR is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMP3FBRT, but more expensive.

12 Rain Cover 6 gauge Bonding strap Use this strap for bonding the enclosure to neutral when required Neutral lugs Service ground lugs () Flat bus cap Incoming lugs Deep bus cap Switch handle Load T fuse connections Switch blades Knockouts Main Fusible Switch Module, Three-Phase, 4 Wire 08Y/0 Vac Fuses not included. All mains are required to be center feed only when the main fusible switch rating is greater than the horizontal bus amperage rating Catalog Number Main Ampere Rating TMP3FT4R 400 IC Rating (Max) kaic Wire Entry Main Wire Size AWG/kcmil Cu/Al -Phase () /0-750 or () /0-300 Main Wire Size AWG/kcmil Cu/Al - Neutral () /0-750 or () /0-300 TMP3FT6R 600 () -600 () -600 TMP3FT8R 800 (4) 3/0-750 (4) 3/0-750 TMP3FTR 00 (4) (4) TMP3FTRST Top (4) (4) TMP3FT6R 600 (6) (6) TMP3FT6RST (6) (6) TMP3FT0R 000 (8) (8) TMP3FT0RST (8) (8) TMP3FB4R 400 () /0-750 or () /0-300 () /0-750 or () /0-300 TMP3FB6R 600 () -600 () -600 TMP3FB8R 800 (4) 3/0-750 (4) 3/0-750 Stud Sets per Phase and Neutral Fuse Not Included. Order Separately. Class T only Class L only. Bolted Pressure Switch Class T only TMP3FBR 00 (4) (4) See footnote TMP3FBRT Bottom (4) -600 (4) -600 See footnote TMP3FBRST 3 00 (4) (4) TMP3FB6R 600 (6) (6) TMP3FB6RST (6) (6) TMP3FB0R 000 (8) (8) TMP3FB0RST (8) (8) Class L only. Bolted Pressure Switch Compression Lug Landing Kit TMP3F8CLL Order Separately TMP3F8CLL Order Separately TMP3FBRT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMP3FBR, but is significantly less expensive. TMP3FBR is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMP3FBRT, but more expensive. 3 Product numbers ending in ST have shunt tripping style bolted pressure switch.

13 Main Fusible Switch Module with Integral Pull Box (Single-Phase and Three-Phase) - EUSERC Unit Meets EUSERC requirements All Modules accept Class T Fuse When meter stacks are to be mounted on handle side of switch, order TMPS spacer. Lugs not included Catalog Number Single-Phase, 3 Wire 0/40 Vac Three-Phase, 4 Wire / Single-Phase, 3 Wire 0/40 Vac, 08Y0 Vac, Main Ampere Rating 40/0 Vac 0/40 Vac TMPFB4RCLL TMP3FB4RCLL 400 TMPFB6RCLL TMP3FB6RCLL 600 TMPFB8RCLL TMP3FB8RCLL 800 TMPFBRCLLT TMP3FBRCLLT 00 IC Rating (Max) kaic Wire Entry 00 Bottom Center-feed only for single-phase meter modules with 800A horizontal bus rating. Mounting End or Center Main Wire Size AWG/kcmil Cu/Al - Phase Compression Lug Landing Kit Included (NEMA -Hole Spacing) Main Wire Size AWG/kcmil Cu/Al - Neutral Compression Lug Landing Kit Included (NEMA -Hole Spacing) Compression Lug Landing Kit Included Main Fusible Switch Modules Fuses and Compression Lugs Class T Fuses Rated at 40V Frame Size Ampere Rating Catalog Number 50 TFUSE TFUSE TFUSE TFUSE TFUSE TFUSE TFUSE A3T00 Class L Fuses Rated at 40V Ampere Rating Catalog Number 600 A4BY A4BY A4BY A4BY A4BY A4BY A4BY A4BY00 Ampere Rating Catalog Number 00 A4BY A4BY A4BY A4BY A4BY A4BY A4BY000 Compression Lugs The following UL listed crimp connectors may be used Wire size (CU only) Mac T & B Burndy Panduit 50 kcmil MSB50-8N 5475 YA9-LN MRB50-8N 54868BE YA9-LN LCC kcmil MSB300-8N 5480 YA30-LN MRB300-8N 54870BE YA30-LN LCC kcmil MSB350-8N 548 YA3-LN MRB350-8N 5487BE YA3-LN LCC kcmil MSB400-8N YA3-LN 54874BE MRB400-8N YA3-LN LCC kcmil MSB500-8N 5486 YA34-LN MRB500-8N 54876BE YA34-LN LCC kcmil MSB600-8N 5489 YA36-LN MRB600-8N 54878BE YA36-LN 700 kcmil kcmil MSB750-8N 543 YA39-LN MRB750-8N 54880BE YA39-LN LCC kcmil MLB50-8N YA9A MULB50-8N YA9AY-N LAB kcmil MLB300-8N YA30A3 606 MULB300-8N YA30AY-N LAB kcmil MLB350-8N YA3A MULB350-8N YA3AY-N LAB kcmil MLB400-8N YA3A MULB400-8N YA3AY-N LAB kcmil MLB500-8N YA34A MULB500-8N YA34AY-N LAB kcmil MLB600-8N YA36A MULB600-8N YA36AY-N LAB kcmil kcmil YA39A5 LAB750- Note: torque / nuts which attach crimp connectors to 45 ft.-lb. (6 N-m) 3

14 Main Fusible Modules, Single-Phase and Three-Phase Factory Installed Lug Kits Amp Rating Main Breaker Catalog No. Phase Wire Size Neutral Wire Size Lugs per Kit TMPFB4R TMPFT4R TMP3FB4R TMP3FT4R TMPFB4RCLL TMP3FB4RCLL TMPFB6R TMPFT6R TMP3FB6R TMP3FT6R TMPFB6RCLL TMP3FB6RCLL TMPFB8R TMPFT8R TMP3FB8R TMP3FT8R TMPFB8RCLL TMP3FB8RCLL Al/Cu: () /0-750 or () /0-300 Accepts compression lugs, landing/phase Al/Cu: () /0-750 or () /0-300 Al/Cu: () -600 Al/Cu: () -600 Accepts compression lugs, landings/phase TMPL40 Al/Cu: (4) 3/0-750 Al/Cu: (4) 3/0-750 lug/kit, 4 holes/lug Accepts compression lugs, landings/phase TMPFBR Al/Cu: (4) -500 Al/Cu: (4) -500 TMPFBRT Al/Cu: (4) -600, lugs/phase Al/Cu: (4) -600 TMPFBRST Al/Cu: (4) -500 Al/Cu: (4) -500 TMPFTR Al/Cu: (4) -600 Al/Cu: (4) -500 TMPFTRST Al/Cu: (4) -600 Al/Cu: (4) -500 TMP3FBR Al/Cu: (8) -600 (4 lugs, holes/lug) TMP3FBRT Al/Cu: (4) -600, TMP3FTR lugs/phase TMP3FTRST TMPFBRCLL TMP3FBRCLL Al/Cu: (4) -600, lugs/phase Accepts compression lugs, 3 landings/phase Al/Cu: (4) -600 Al/Cu: (4) -600 TMP3FB6R Al/Cu: (8) -600 Al/Cu: (8) -600 TMP3FB6RST Al/Cu: (8) -600 Al/Cu: (8) -600 TMP3FT6R Al/Cu: (5) Al/Cu: (5) TMP3FT6RST Al/Cu: (5) Al/Cu: (5) TMP3FB0R Al/Cu: (8) -600 Al/Cu: (8) -600 TMP3FB0RST Al/Cu: (8) -600 Al/Cu: (8) -600 TMP3FT0R Al/Cu: (6) Al/Cu: (6) TMP3FT0RST Al/Cu: (6) Al/Cu: (6) Optional Lug Kit 4 Amp Rating Main Breaker Catalog No. Phase Wire Size Lugs per Kit Neutral Catalog # TMPFT4R TMP3FT4R TMPFB4R TMP3FB4R TMPFB6R TMPFT6R TMP3FB6R TMP3FT6R TMPFB8R TMPFT8R TMP3FB8R TMP3FT8R TMPL40 TMPL40 Al/Cu: (4) 3/0-750; 4 cables/lug Al/Cu: (4) 3/0-750; 4 cables/lug TMP3F8CLL TMP3F8CLL TMP3F8CLL Compression Compression Compression

15 Bonding strap Use this strap for bonding the enclosure to neutral when required Rain Cover 6 gauge Horizontal bus Tin-plated aluminum with captive hardware Line Lugs Factory Installed Deep Bus Cap Flat Bus Cap Phase C Bus Bar for Single-Phase Units is Omitted Knockouts Main Lug Module, Single-Phase, 3 Wire 0/40 Vac Lugs included. Catalog Number Main Ampere Rating Use 3-Phase 400 Use 3-Phase 600 TMPL8R 800 TMPLR 00 IC Rating (Max) kaic 00 Wire Entry Bottom/ Top Mounting End or Center Main Wire Size AWG/ kcmil Cu/Al - Phase () /0-750 or (4) /0-300 (3) /0-750 or (6) /0-300 Main Wire Size AWG/kcmil Cu/Al - Neutral () /0-750 or (4) /0-300 (3) /0-750 or (6) /0-300 Stud Sets per Phase and Neutral TMPL6R 600 (6) (6) TMPL0R TMPL0RCRIS Bottom/ Top Bottom/ Top End or Center End or Center Limited to the lowest marked short circuit rating of the main and meter modules used. (8) /0-750 (8) / (8) /0-750 (8) / Compression Lug Landing Kit Order Separately 5

16 Bonding strap Use this strap for bonding the enclosure to neutral when required Rain Cover 6 gauge Horizontal bus Tin-plated aluminum with captive hardware Line lugs Factory Installed Flat Bus Cap Deep Bus Cap Knockouts Main Lug Module, Three-Phase, 4 Wire 08Y/0 Vac Lugs included. Catalog Number TMP3L4R TMP3L4RCU TMP3L6R TMP3L6RCU TMP3L8R TMP3L8RCU Main Ampere Rating 400 IC Rating (Max) kaic 00 Wire Entry Bottom/ Top Mounting End or Center Main Wire Size AWG/ kcmil Cu/Al - Phase () or () /0-50 Main Wire Size AWG/kcmil Cu/Al - Neutral () or () /0-50 Stud Sets per Phase and Neutral 600 () () TMP3LR 00 () /0-750 or (4) /0-300 (3) /0-750 or (6) /0-300 () /0-750 or (4) /0-300 (3) /0-750 or (6) /0-300 TMP3L6R 600 (6) (6) TMP3L0R 000A (8) /0-750 (8) /0-750 Limited to the lowest marked short circuit rating of the main and meter modules used. Copper bused. Compression Lug Landing Kit Order Separately Main Lug with Feed Through, Three Phase, Four Wire / Single Phase, Three Wire 0/40 Vac, 08Y/0 Vac Catalog Number Main Amperage KAIC Incoming Line Outgoing Load Stud Sets per Phase and Neutral Compression Lug Landing Kit TMP3LRCRIS 00A (5) Up to 750 MCM per Phase/Neutral (AL/CU) (5) Up to 750 MCM per Phase/Neutral (AL/CU) TMP3L6RCRIS 600A 00 TMP3L0RCRIS 000A (8) /0-750 MCM per Phase/Neutral (AL/CU) (8) /0-750 MCM per Phase/Neutral (AL/CU) 6

17 Main Lug Modules, Single-Phase and Three-Phase Factory Installed Lug Kits Amp Rating Main Lug (Terminal Box) 400 TMP3L4R Lug Kit Catalog Number TMMLK (w/instr.) Phase Wire Size Neutral Wire Size Lugs per Kit Total Lugs per Device AL/CU: () /0-600 or () #6-50 AL/CU: () /0-600 or () #6-50 lug/kit, lug/phase, hole lug 600 TMP3L6R TMPAL30 AL/CU: () /lug AL/CU: () /lug lug/kit, lug/phase TMPL8R TMP3L8R TMPLR TMP3LR, TMP3LRCRIS TMPL6R TMP3L6R, TMP3L6RCRIS TMP3L0R, TMP3L0RCRIS TMPL0R, TMPL0RCRIS TMPL750 TMPL750 AL/CU: () /0-750 or (4) /0-300 AL/CU: (3) /0-750 or (6) /0-300 AL/CU: () /0-750 or (4) /0-300 AL/CU: (3) /0-750 or (6) /0-300 lugs/phase, 3 lugs/kit 3 lugs/phase, 3 lugs/kit TMPAL30 AL/CU: (6) AL/CU: (6) lug/kit, 3 lugs/phase 9 lugs total lugs total AL/CU: (8) /0-750 AL/CU: (8) /0-750 lug/kit, 3 lugs/phase lugs total Optional Lug Kit Amp Rating Main Lug (Terminal Box) Phase Lug Kit Catalog Number Phase Wire Size Lugs per Kit 400 TMP3L4R TMPAL30 Al/Cu: () /lug lug/kit, lug/phase 600 TMP3L6R TMPL8R TMP3L8R TMPLR TMP3LR TMPL6R TMP3L6R Compression Lug Kit Catalog Number TMP36LCLL Compression Wire Size Compression TMPAL30 Al/Cu: () lug/kit, lug/phase TMP3LCLL Compression TMP3L6BLK Al/Cu: (4) /0-750 or (8) /0-300 kit/device, 4 connector assy's w/4 lugs each (6 total lugs), assy/phase TMP3L6CLL Compression Lugs per Kit studs per phase, double stack for up to conductors per phase 4 studs per phase, double stack for up to 4 conductors per phase 7

18 Bonding strap Use this strap for bonding the enclosure to neutral when required Rain Cover 6 gauge Load Lug Line stud sets Factory installed tin-plated aluminum with / 3 x studs including hardware phase and neutral NEMA -hole spacing Lugs are customer or utility supplied Main Pull Box Module, Single-Phase, 3 Wire 0/40 Vac Lugs included. Cross bus not included. Catalog Number Main Ampere Rating TMPU4R 400 TMPU8R 800 IC Rating (Max) kaic 00 Wire Entry Bottom/ Top Mounting End Main Wire Size AWG/ kcmil Cu/Al - Phase () /0-750 or () /0-300 (Load) () /0-750 or (4) /0-300 (Load) Main Wire Size AWG/kcmil Cu/Al - Neutral () /0-750 or () /0-300 (Load) () /0-750 or (4) /0-300 (Load) Stud Sets per Phase and Neutral TMPUR 00 (4) -600 Load (4) -600 Load 3 Limited to the lowest marked short circuit rating of the main and meter modules used. Compression Lug Landing Kit Included 8

19 Rain Cover 6 gauge Bonding strap Use this strap for bonding the enclosure to neutral when required Load Lugs Knockouts Two large knockouts in bottom Line stud sets Factory installed tin-plated aluminum with / 3 x studs including hardware phase and neutral NEMA -hole spacing Lugs are customer or utility supplied Sealing provision Hole in stud welded to enclosure, cover and wing nuts Main Pull Box Module, Three-Phase, 4 Wire 08Y/0 Vac Lugs included. Cross bus not included. Catalog Number Main Ampere Rating TMP3U4R 400 TMP3U8R 800 IC Rating (Max) kaic 00 Wire Entry Bottom/ Top Mounting End Main Wire Size AWG/ kcmil Cu/Al - Phase () /0-750 or () /0-300 (Load) () /0-750 or (4) /0-300 (Load) Main Wire Size AWG/kcmil Cu/Al - Neutral () /0-750 or () /0-300 (Load) () /0-750 or (4) /0-300 (Load) Stud Sets per Phase and Neutral TMP3UR 00 (4) -600 Load (4) -600 Load 3 Limited to the lowest marked short circuit rating of the main and meter modules used. Compression Lug Landing Kit Included 9

20 Meter Stack Modules, Residential Overview Raintight Cap Shipped for each meter stack module and main device. Vertical Bus Bar One-piece vertical bus bar from phase balancing joints to meter socket helping to reduce chances of hot spots. Solid Meter Barrier Meter socket and main tenant breaker/ wireway sections are separated by solid meter barrier to protect against power theft and help improve safety. Tenant Breakers Reliable connection directly to the bus bars. 5A modules allow plug-in breakers (5-5A). 00A modules allow bolt-on breakers 60-00A Meter Socket Meter socket base installed without any fasteners which reduces hot spots, makes it easily replaceable and improves connections to vertical bussing. Moveable Phase Balancing Connectors Four-wire horizontal bussing allows you to use any residential module for PH or 3PH incoming service. Shipped with A & B phase connection from factory, field phase balancing can be easily accomplished for the AC and BC phases by moving Barrelshaped and Z-shaped phase connectors on two-thirds of the other meter stacks. Superior Finish Rust inhibiting phosphate primer and gray baked enable are standard on the modules. All outdoor enclosures have galvanized steel construction to improve rigidity. Neutral Assembly A convenient termination for neutral conductors that is in the wireway of each meter stack module. Enclosed Horizontal Bus Non-removable barrier encloses the 800A or 00A horizontal bus passing through tenant breaker section. This provides added security and protection. Knockouts Included in the bottom endwall. Bus Connection Mains and Meter Modules slip together quickly and smoothly with front-accessible captive bolts securing the two sections without removing interiors or bus access plates. Main bus joint bolts torque to 5 ft. lbs. Equipment Ground Bar Factory installed in the side gutter which is a standard feature that is moveable to top or bottom of the gutter. 0

21 Meter Stack Modules Residential Single Phase 800A Horizontal Bussing 5 & 00A Sockets 800 amp, 4 Wire Crossbus (Aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Socket Amps 5 00 No. of Sockets Ring Type Socket Catalog Number Ringless Type Socket (4 Jaw Socket Standard) Ringless Type Socket (4 Jaw Socket Standard) Horned Bypass Factory Installed TMP8R TMPR8R TMPR8RHB 3 TMP83R TMPR83R TMPR83RHB 4 TMP84R TMPR84R TMPR84RHB 5 TMP85R TMPR85R TMPR85RHB 6 TMP86R TMP8R6R TMP8R6RHB TMP80R TMPR80R TMPR80RHB 3 TMP830R TMPR830R TMPR830RHB 4 TMP840R TMPR840R TMPR840RHB 5 TMP850R TMPR850R TMPR850RHB 5 TMP850RBUS, TMPR850RBUS TMPR850RHBBUS BUS suffix indicates change to centerline of horizontal bussing from 8.88" to 4.0" from bottom of unit One snap-type, aluminum sealing ring (TSR5) per socket included 800 amp, 4 Wire Cross bus (copper) - CON ED Approved UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Catalog Number Socket Amps 5 No. of Sockets Factory Phase Balancing NEMA Indoor Enclosure Ring Type Socket Factory Phase Balanced with Copper Bus NEMA 3R Outdoor Enclosure AB TMP8AB TMP8RAB AC TMP8AC TMP8RAC BC TMP8BC TMP8RBC AB TMP83AB TMP83RAB AC TMP83AC TMP83RAC BC TMP83BC TMP83RBC AB TMP84AB TMP84RAB AC TMP84AC TMP84RAC BC TMP84BC TMP84RBC AB TMP85AB TMP85RAB AC TMP85AC TMP85RAC BC TMP85BC TMP85RBC

22 Meter Stack Modules Residential Single Phase MEG Approved 800A Horizontal Bussing 5 & 00A Sockets 800 amp, 4 Wire Crossbus (Aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Meter Equipment Group Approved These MEG approved units have an added cotter pin that eliminates failure of the metering stabs when the meter is plugged into the meter base. Socket Amps 5 00 No. of Sockets Ring Type Socket Ringless Type Socket (4 Jaw Socket Standard) Ringless Type Socket (4 Jaw Socket Standard) Horned Bypass Factory Installed TMP8RF TMPR8RF TMPR8RHBF 3 TMP83RF TMPR83RF TMPR83RHBF 4 TMP84RF TMPR84RF TMPR84RHBF 5 TMP85RF TMPR85RF 6 TMP86RF TMPR86RF TMPR86RF TMPR80RF 3 TMP830RF TMPR830RF 4 TMP840RF TMPR840RF TMPR840RHBF 5 TMPR850RF One snap-type, aluminum sealing ring (TSR5) per socket included

23 Meter Stack Modules Residential Single Phase 00A Horizontal Bussing 5 & 00A Sockets 00 amp, 4 Wire Crossbus (aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Socket Amps 5 00 No. of Sockets Ring Type Socket Catalog Number Ringless Type Socket (4 Jaw Socket Standard) Ringless Type Socket (4 Jaw Socket Standard) Horned Bypass Factory Installed TMPR TMPRR TMPRRHB 3 TMP3R TMPR3R TMPR3RHB 4 TMP4R TMPR4R TMPR4RHB 5 TMP5R TMPR5R TMPR5RHB 6 TMP6R TMPR6R TMPR6RHB TMP0R TMPR0R TMPR0RHB 3 TMP30R TMPR30R TMPR30RHB 4 TMP40R TMPR40R TMPR40RHB 5 TMP50R TMPR50R TMPR50RHB 5 TMP50RBUS, TMPR50RBUS TMPR50RHBBUS BUS suffix indicates change to centerline of horizontal bussing from 8.88" to 4.0" from bottom of unit One snap-type, aluminum sealing ring (TSR5) per socket included 3

24 Meter Stack Modules Residential Single Phase MEG Approved 00A Horizontal Bussing 5 & 00A Sockets 00 amp, 4 Wire Crossbus (Aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Stack () 4-4 Equipment Ground per Socket, Factory Installed Meter Equipment Group Approved These MEG approved units have an added cotter pin that eliminates failure of the metering stabs when the meter is plugged into the meter base. Socket Amps 5 00 No. of Sockets Ring Type Socket Ringless Type Socket (4 Jaw Socket Standard) Ringless Type Socket (4 Jaw Socket Standard) Horned Bypass Factory Installed 4 TMPR4RF TMPR4RHBF 5 TMPR5RF TMPR5RHBF 6 TMPR6RF 4 TMP40RF TMPR40RF TMPR40RHBF 5 TMPR50RF One snap-type, aluminum sealing ring (TSR5) per socket included 4

25 Tenant Main Breakers for PH Residential Meter Modules (800A & 00A Horizontal Bussing) Tenant Main Breakers for 5A, Pole Sockets Amps 0kAIC kaic Wire Size 60 THQL60 THHQL60 () #8-#3 CU; #8-#3AL 70 THQL70 THHQL70 80 THQL80 THHQL80 90 THQL90 THHQL90 () #6-/0 CU; #4-#/0 AL 00 THQL00 THHQL00 () #-/0 CU; #-/0 AL 0 THQL0 THHQL0 5 THQL5 THHQL5 () #-/0 CU; #-/0 AL 5 TMQL5SSF Sub-Feed lug. No overcurrent protection. Tenant Main Breakers for 5A, Pole Sockets Amps QL 4 kaic 60 TMQL60 70 TMQL70 80 TMQL80 90 TMQL90 00 TMQL00 Wire Size #8-# (Cu) or #8-/0 (Al) 5 TMQL5 /0 - #4 Tenant Main Breakers for 00A, Pole Sockets Amps 0kAIC kaic Wire Size 00 TQD00 THQD00 5 TQD5 THQD5 50 TQD50 THQD50 75 TQD75 THQD75 00 TQD00 THQD00 () #-300 CU; #-300 AL Tenant Main Circuit Breakers for 00A, Pole Sockets Amps QD Old Catalog # - Obsolete. Replaced by QV. QV 00 kaic New Catalog # Wire Size 60 TMQV060MM #4-/0 only 70 TMQD070 TMQV070MM 80 TMQD080 TMQV080MM 90 TMQD090 TMQV090MM 00 TMQD00 TMQV00MM 0 TMQV0MM 5 TMQD5 TMQV5MM 50 TMQD50 TMQV50MM 75 TMQD75 TMQV75MM 00 TMQD00 TMQV00MM For 75A-00A use TMQV5L to get 300MCM terminals. #4-4/0 only std = #4-4/0 5

26 Meter Stack Modules, Commercial Overview Indoor/Outdoor Construction Raintight caps, meter covers and lockable raintight tenant breaker covers make it convenient for you to use any of our meter modules for N or N3R applications. Tenant Breaker Range All modules accept 5-5A bolt-on breakers up to 00K interrupting rating. The breakers are UL listed for series rating with the breakers in GE load centers and panels. Meter Socket The 5-Jaw and 7-jaw meter sockets include a built-in lever bypass and jaw release. The ground wire is factory connected. Barrier A solid metal barrier separates the meter socket section from tenant breaker in wireway section. The unmetered vertical bus is enclosed to guard against power theft. Neutral Assembly Located in the wireway of each module, the assembly permits convenient termination of the neutral conductors. Mains and Modules Connect together quickly and smoothly with front-accessible bolts securing them without removing socket interiors or bus access plates. Main bus joint bolts torque to 5 ft. lbs. Enclosed Horizontal Bus Non-removable metal barrier encloses 00A horizontal bus when passing through tenant breaker section which adds security. Ground Bars The factory-installed equipment ground bars are provided in both top and bottom gutters. End Walls Top cap is removable and does not contain knockouts so contractors can position and punch holes where needed. Numerous KO s in the back and bottom are included for flexibility. 6

27 Meter Stack Modules Commercial Single-Phase 5A/400A Ringless Sockets w/ Lever Bypass Single-Phase/3 Wire 0/40 Vac or Three-Phase, 4 Wire, Horizontal Bus, 08Y/0 Vac System Voltage 00 amp, 4 Wire cross bus (aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Socket () 4- Equipment Ground Kit per Socket, Factory Installed Only 5A and 400A Ringless Type Meter Stacks contain Lever Bypass 5A and 00A Meter Sockets do not contain Lever Bypass Socket Amps No. of Sockets Catalog Number TMPRR TMPRR 3 TMPR3R 4 TMPR4R TMPR40RB,3 TMPR40RB,3 TMPK40RB TMPK40RBA One 400A tenant main breaker included. Two 400A tenant breakers included. 3 Main Breaker Modules Alternate Rating Plugs table for alternate 400A Rating Plugs Factory Installed Fifth Jaw (TM5JA Bused) Included Meter Stack Modules Commercial Single-Phase 00A Ring Sockets w/ Test Bypass Kits EUSERC Single-Phase / 3 Wire 0/40 Vac or Three-Phase, 4 Wire, Horizontal Bus, 08Y/0 Vac System Voltage 00 amp, 4 Wire cross bus (aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Socket () 4- Equipment Ground Kit per Socket, Factory Installed 00A Meter Sockets do not contain Lever Bypass Ring Type Socket with Test Bypass Kit and Factory-Set Phase Balancing Meet EUSERC requirement Socket Amps 00 No. of Sockets 3 Catalog Number TMP80RTAB TMP80RTAC TMP80RTBC TMP0RTAB TMP0RTAC TMP0RTBC TMP30RTAB TMP30RTAC TMP30RTBC Suffixes AB, BC, AC reflect the factory-set phase balancing. Factory Installed Fifth Jaw (TM5JA Bused) Included 7

28 Tenant Main Breakers for PH Commercial Meter Stack Modules (00A Horizontal Bussing) Tenant Main Circuit Breakers for 5A, Pole Sockets Amps 0kAIC Wire Size 5 TEB05 0 TEB00 5 TEB05 30 TEB TEB TEB TEB TEB TEB TEB TEB TEB TQD00 5 TQD5 50 TQD50 75 TQD75 00 TQD00 5 Use TMQV () #4-3 CU; #- AL () #6/0 CU; #4-/0 AL () #-300 CU; #-300 AL Tenant Main Circuit Breakers for 5A, Pole Sockets Amps kaic Wire Size 00 THQD00 5 THQD5 50 THQD50 75 THQD75 00 THQD00 5 Use TMQV () #-300 CU; #-300 AL Tenant Main Circuit Breakers for 00A/5A, Pole Sockets Amps QD Old Catalog # - Obsolete. Replaced by QV. QV 00 kaic New Catalog # Wire Size TMQV060MM #4-/0 only 70 TMQD070 TMQV070MM 80 TMQD080 TMQV080MM 90 TMQD090 TMQV090MM 00 TMQD00 TMQV00MM 0 -- TMQV0MM 5 TMQD5 TMQV5MM 50 TMQD50 TMQV50MM 75 TMQD75 TMQV75MM 00 TMQD00 TMQV00MM 5 TMQD5 TMQV5MM For 75A-5A use TMQV5L to get 300MCM terminals. #4-4/0 only std = #4-4/0 8

29 Meter Stack Modules Commercial Three-Phase, 5A/400A Ringless Sockets w/ Lever Bypass Three-Phase / 4 Wire, 40-0 Vac, Three-Phase / 4 Wire 08Y/0Vac 00 amp, 4 Wire cross bus (aluminum) UL Listed Front Accessible Field Phase Balancing by Meter Socket () 4- Equipment Ground Kit per Socket, Factory Installed Swingaway Mounting Feet Factory Installed Only 5A and 400A Ringless Type Meter Sockets contain Lever Bypass 5A and 00A Meter Sockets do not contain Lever Bypass Ringless Type Sockets with Lever Bypass Socket Amps No. of Sockets Catalog Number Factory Installed Seventh Jaw (7 Terminal) 5 TMPR3R TMPR3R 3 TMPR33R 4 TMPR34R TMPR340TR,3 TMPR340RB, Included 400 Meter Stack Modules Commercial Three-Phase 00A Ring Sockets w/ Test Bypass Kits EUSERC Three-Phase / 4 Wire, 40-0 Vac, Three-Phase / 4 Wire 08Y/0Vac 800 amp, 4 Wire Cross bus (copper) UL Listed TMPR340RB,4 TMPK340RB TMPK340RBA Shipped from the factory as 7-jaw units (7 terminal.) 400 Amp tenant breaker included, 65 kaic 3 Requires two tenant main breakers, 400 amp maximum sum of branch ratings. Cannot be used to serve a single 400A load. 4 Two 400 Amp tenant breakers included. Front Accessible Field Phase Balancing by Meter Stack Ring Type Socket EUSERC Socket Amps No. of Sockets Catalog Number Factory Installed Seventh Jaw (7 Terminal) 00 TMP30RT 3 Included TMP380RT 3 3 TMP330RT 3 3 Meets EUSERC requirements. "T" suffix indicates EUSERC test bypass kit included. 9

30 Tenant Main Breakers for 3PH Commercial Meter Stack Modules (00A Horizontal Bussing) Tenant Main Circuit Breakers for 00A/5A, 3 Pole Sockets Amps 0kAIC Wire Size 5 TEB305 0 TEB300 5 TEB TEB TEB TEB TEB TEB TEB TEB TEB TEB3090 () #4-3 CU; #- AL () #6/0 CU; #4-/0 AL 00 TEB300 () #3-3/0 CU; #-3/0 AL 5 TQD35 50 TQD TQD TQD300 5 Use TMQV () #-300 CU; #-300 AL Tenant Main Circuit Breakers for 00A/5A, 3 Pole Sockets Amps kaic Wire Size 00 THQD300 5 THQD35 50 THQD THQD THQD300 5 Use TMQV () #-300 CU; #-300 AL Tenant Main Circuit Breakers for 00A/5A, 3 Pole Sockets Amps QD Old Catalog No. - Obsolete. Replaced by QV. QV 00 kaic New Catalog No. Wire Size 60 TMQV3060 #4-/0 only 70 TMQD3070 TMQV TMQD3080 TMQV TMQD3090 TMQV TMQD300 TMQV300 0 TMQV30 5 TMQD35 TMQV35 50 TMQD350 TMQV TMQD375 TMQV TMQD300 TMQV300 5 TMQD35 TMQV35 For 75A-5A use TMQV5L3 to get 300MCM terminals. #4-4/0 only std = #4-4/0 30

31 SUITABLE FOR CENTER-FEED APPLICATIONS ONLY Horizontal bus is rated 00 amps maximum. The load on the horizontal bus may not exceed 00 amps in either direction from the point of connection of the main circuit breaker. Overall load is limited to the rating of the main circuit breaker. For applications where the main module ampere rating is greater than that of the meter stack horizontal bus, the main module must be placed in the middle of the lineup (Figure A). The engineer of record must provide calculations on the plans to show that the horizontal bussing will not be overloaded on either side. This situation, called Center-Feeding, can happen in either 800A or 00A horizontal bus meter stack applications, depending on the main ampere rating. Refer to chart below for amperage and bus information. NOTE: Figure B shows the incorrect configurations. Does the Application Require Electrician to Center-Feed the Main Module? Amps of Main Breaker, Lug or Switch 800A Horizontal Bus 00 Horizontal Bus 400A 800A No No 000A Yes No 00A Yes No 400A Yes Yes 600A Yes Yes 000A Yes Yes Main Main Main Correct This configuration is centered and will balance the load between left and right-side horizontal bus leaving the main section Incorrect This configuration will overload the left-side horizontal bus that leaves the main section Incorrect This configuration will overload the right-side horizontal bus that leaves the main section Figure A Figure B 3

32 Modular Metering System Short Circuit Rating -UL Listed Series ratings are subject to change. Please see DET-008 for the most up to date series ratings. Available Short Circuit Current rms Symmetrical 40 Volts AC Main Module Switch Breaker Lug Meter Module Tenant Main Breaker Type Load Center Branch Breaker Type Panelboard Branch Breaker Type 0,000 All All All THQL, TQD, TEB, TMQL, TMQV THQP, THQL THQL, THQB,000 All All All THHQL, THQD, TMQL, TMQV THQP, THQL THQL, THQB 4,000 All All All TMQL, TMQV THQP, THQL THQL, THQB 65,000 All A: TMPSHB A: TMPSB All TMQV THQP, THQL THQL, THQB 00,000 All A: TMPSHB All TMQV THQP, THQL THQL, THQB Main Pull Box Module is UL Listed for use with and at the short circuit rating of main switch and breaker modules Meter Mod III Main Breaker to Tenant Breaker Series Ratings - 5A Sockets Series ratings are subject to change. Please see DET-008 for the most up to date series ratings. Series Ratings 400A-000A PH (P) Main Breakers to -Pole THQL/THHQL (70-5A) - 5A Sockets Meter Mod III Main Breaker Section Meter Mod III Breaker Frame TMPSB4R SGH 400 Main Phase Series Rating of Main (AIC) 65,000 TMPSHB4R SGL ,000 TMPSB6R SGH ,000 TMPSHB6R SGL ,000 TMPSB8R SKH ,000 TMPSB0R SKH ,000 TMPSBR SKH 00 65,000 TMPBB4R, TMPBB4RAR, TMPBB6R, TMPBB6RAR, TMPBB6RST, TMPBT6R, TMPBT6RAR, TMPBT6RST, TMPBT0R, TMPBB0R, TMPBB0RAR Does not include 60A THQL/THHQL Tenant Breaker (Use 70A Instead) Voltage of Main Voltage of Tenant Approved for Modular Metering 08/0 Vac 0/40 Vac Yes RD 00,000 08/0 Vac 0/40 Vac No Series Ratings 400A-000A 3PH (3P) Main Breakers to -Pole THQL/THHQL (70-5A) - 5A Sockets Meter Mod III Main Breaker Section Meter Mod III Breaker Frame TMP3SB4R SGH 400 Main Phase Series Rating of Main (AIC) 65,000 TMP3SHB4R SGL ,000 TMP3SB6R SGH ,000 TMP3SHB6R SGL ,000 TMP3SB8R SKH ,000 TMP3SB0R SKH ,000 TMP3SBR SKH 00 65,000 TMP3FB4R, TMP3FB4RAR, TMP3FT4R, TMP3FT4RAR, TMP3FB6R, TMP3FB6RAR, TMP3FB6RST, TMP3FT6R, TMP3FT6RAR, TMP3FT6RST, TMP3FT0R, TMP3FT0RAR, TMP3FB0R, TMP3FB0RAR Does not include 60A THQL/THHQL Tenant Breaker (Use 70A Instead) Voltage of Main Voltage of Tenant Approved for Modular Metering 08/0 Vac 0/40 Vac Yes RD 3 00,000 08/0 Vac 0/40 Vac No 3

33 Meter Mod III Main Breaker to Tenant Breaker Series Ratings - 5A Sockets (continued) Series ratings are subject to change. Please see DET-008 for the most up to date series ratings. Series Ratings 400A-000A PH (P) Main Fusible Switches to -Pole THQL/THHQL (70-5A) - 5A Sockets Meter Mod III Main Fusible Switch Section TMPFT4R TMPFB4R TMPFT6R TMPFB6R TMPFT8R Meter Mod III Fuse Type Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved for Modular Metering T Fuse 00,000 08/0 Vac 0/40 Vac Yes T Fuse TMPFB8R TMPFTR TMPFBR T or L Fuse 00,000 08/0 Vac 0/40 Vac No TMPFBRT T Fuse Field convertible to Class L fusing, no kit required Switches up to 600A rated for series rating at 4K and below; switches up to 400A rated for series rating from >4K - 00K. Series Ratings 400A-000A 3PH (3P) Main Fusible Switches to -Pole THQL/THHQL (70-5A) - 5A Sockets Meter Mod III Main Fusible Switch Section TMP3FT4R TMP3FB4R TMP3FT6R TMP3FB6R TMP3FT8R TMP3FB8R TMP3FTR TMP3FBR TMP3FBRT TMP3FBRST TMP3FT6R, TMP3FB6R, TMP3FB6RST, TMP3FT0R, TMP3FB0R, TMP3FB0RST Meter Mod III Fuse Type Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved for Modular Metering T Fuse 3 00,000 08/0 Vac 0/40 Vac Yes T Fuse T or L Fuse T Fuse T or L Fuse 3 00,000 08/0 Vac 0/40 Vac No L Fuse 3 00,000 08/0 Vac 0/40 Vac No Field convertible to Class L fusing, no kit required Switches up to 600A rated for series rating at 4K and below; switches up to 400A rated for series rating from >4K - 00K. 33

34 Meter Mod III Main Breaker to Tenant Breaker Series Ratings - 00A Sockets Series ratings are subject to change. Please see DET-008 for the most up to date series ratings. Series Ratings 400A-000A PH (P) Main Breakers to -Pole TQD (00-00A) - 00A Sockets Meter Mod III Main Breaker Section Meter Mod III Breaker Frame TMPSB4R SGH 400 Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved for Modular Metering TMPSHB4R SGL ,000 No TMPSB6R SGH ,000 Yes TMPSHB6R SGL ,000 08/0 Vac 0/40 Vac No TMPSB8R SKH ,000 Yes TMPSB0R SKH ,000 No TMPSBR SKH 00 TMPBBRAR, TMPBB4R, TMPBB4RAR, TMPBB6R, TMPBB6RAR, TMPBB6RST, TMPBT6R, TMPBT6RAR, TMPBT6RST, TMPBT0R, TMPBT0RAR, TMPBB0R, TMPBB0RAR RD 00,000 08/0 Vac 0/40 Vac No Series Ratings 400A-000A 3PH (3P) Main Breakers to -Pole TQD (00-00A) - 00A Sockets Meter Mod III Main Breaker Section Meter Mod III Breaker Frame TMP3SB4R SGH 400 Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved for Modular Metering TMP3SHB4R SGL ,000 No TMP3SB6R SGH ,000 Yes TMP3SHB6R SGL ,000 08/0 Vac 0/40 Vac No TMP3SB8R SKH800 65,000 Yes TMP3SB0R TMP3SBR SKH000 SKH00 65,000 No TMP3FB4R, TMP3FB4RAR, TMP3FT4R, TMP3FT4RAR, TMP3FB6R, TMP3FB6RAR, TMP3FB6RST, TMP3FT6R, TMP3FT6RAR, TMP3FT6RST, TMP3FT0R, TMP3FT0RAR, TMP3FB0R, TMP3FB0RAR RD 3 00,000 08/0 Vac 0/40 Vac No 34

Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families

Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families Modular Metering Stock Selection Guide Meter Mod * III and Mini Mod * III Product Families Table of Contents Page No. Nomenclature 3 Main Breaker Module, Single-Phase, 3 Wire, 0/40 Vac 4 Main Breaker Module,

More information

Modular Metering Application Guide

Modular Metering Application Guide GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

Modular Metering Construction Details

Modular Metering Construction Details GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single

More information

Modular Metering Section 2

Modular Metering Section 2 Mini Mod III Nomenclature...-3 Photos...-4 Ring -Type and Ringless...-5 Ring -Type and Ringless - MG pproved 5 & 00 Sockets...-6 Tenant Main reakers for Mini Mod Product Family...-7 Factory Installed Lug

More information

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering for GE Meter Mod * III Modular Metering Your guide to GE s GE tenant main circuit breakers are typically used in residential and light commercial group metering applications. This product category offers

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

THQL1120AF2 THQL1120AF2 Arc Fault BRKR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections

More information

Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

Section 1. Load Centers and Circuit Breakers.  Section Updated 11 / 2014 Section Updated 11 / 2014 Q-Line Circuit Breakers Product Features and Benefits...1-2 PowerMark Gold Load Centers Product Features and Benefits...1-3 PowerMark Gold and Plus Load Centers Product Number

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

Power Mod. Introduction.

Power Mod. Introduction. Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination

More information

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection .11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

POWER PRODUCT Meter Centres Contents

POWER PRODUCT Meter Centres Contents POWER PRODUCT Meter Centres Contents General Specifications - Catalogue Numbering System - 40V Meter Centre Overview - Features & Benefits -3 Procedure -5 Switches and Tap Boxes -6 Meter Stacks -7 Socket

More information

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .11 Metering Products Systems for Residential and Commercial Application Systems for Residential and Commercial Applications Product Description Group metering is a service entrance product line that consists

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Meter Centers & Loadcenters Group Metering

Meter Centers & Loadcenters Group Metering June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through

More information

Typical AEP Panelboard

Typical AEP Panelboard Typical AEP Panelboard 400/600/800A Installation Consult instructions NEMA PB-1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Typical AD Panelboard

Typical AD Panelboard Typical AD Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from supplier.

More information

Molded Case Circuit Breakers Section 3 Q-Line Circuit Breakers

Molded Case Circuit Breakers Section 3 Q-Line Circuit Breakers Molded Case Circuit Breakers Section 3 QLine Circuit Breakers Cablein Cableout (luglug) 240V Class TQD 240 Vac, Internal Common Trip # of Ampere 240 Vac Price Poles Rating Interrupting Rating Product Number

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Typical AQ/AL Panelboard

Typical AQ/AL Panelboard Typical AQ/AL Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from

More information

Typical ADP Panelboard

Typical ADP Panelboard Typical ADP Panelboard 400/600/800A Installation Consult instructions NEMA PB-1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Typical AE Panelboard

Typical AE Panelboard Typical AE Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from supplier.

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

American Electric Supply, Inc.

American Electric Supply, Inc. American Electric Supply, Inc. 6 S. Maple Street Date: 0/8/204 Corona, CA 92880 Telephone: 95-80-4665 Email: bmcdonald@amelect.com Fax: 95-552-626 Speedi Version: V 0.6 Valued Customer, Bill of Material

More information

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

SAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)

SAFETY SOCKET BOX. Note 8 3 MIN. 3 Max. (200 A) .&. SAFETY SOCKET BOX USE: 1 12/24V 1A & 2A 4 Terminal EUSERC Dwg. No's 34 & 35 (With Factory Installed Test-Bypass Facilities) Refer to SR-452 for the complete Front View Lower-Panel Removed Note 3 3"

More information

REC Municipal Meter Mounting Equipment

REC Municipal Meter Mounting Equipment REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Typical AE Panelboard

Typical AE Panelboard Typical AE Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from supplier.

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

Evolution Series Switchboards

Evolution Series Switchboards GE Energy Evolution Series Switchboards Quick Reference imagination at work Main Lug Main Device Width (W) Switchboard Frame Neutral Bus Width (W) Switchboard Frame Neutral Bus Cover 3 A Ground Bar 10

More information

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection... .5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

GE 8000-Line Motor Control Centers

GE 8000-Line Motor Control Centers GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service

More information

CON EDISON EQUIPMENT

CON EDISON EQUIPMENT CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

EZ Meter-Pak Meter Centers

EZ Meter-Pak Meter Centers NEMA 3 onstruction Vac Maximum, for use on A systems, suitable for use as ervice Equipment. tility ompany equirements: eview local utility requirements to ensure that metering equipment meets their standards.

More information

Pow-R-Line 3E Panelboard

Pow-R-Line 3E Panelboard This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided

More information

Meter Mains - Without Bypass

Meter Mains - Without Bypass - 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat

More information

Lighting Panelboards. P2 Panelboards

Lighting Panelboards. P2 Panelboards Lighting Panelboards P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled options to meet virtually any lighting panel application. The

More information

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description .5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design Selection and Application Guide busway system XJ-L Cost-effective Power Distribution Compact Design Specifications New for 2007..400A XJ-L Busway XJ-L Busway is available up to 400A. First introduced in

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

Small Project Product Selection Guide

Small Project Product Selection Guide Small Project Product Selection Guide At your GE Distributor today! Panelboards Transformers Safety Switches NEMA Combo Starters Lighting Contactors imagination at work Small Projects Same Day When you

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

Section 3: Molded Case Circuit Breakers

Section 3: Molded Case Circuit Breakers Section : Molded Case Circuit Breakers Molded Case Circuit Breakers Features...-2 Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units Features...- Molded Case Circuit Breakers Quick Reference

More information

SUBMITTAL TRANSMITTAL

SUBMITTAL TRANSMITTAL SUBMITTAL TRANSMITTAL GENERAL CONTRACTORS 835 GIL HARBIN INDUSTRIAL BLVD. VALDOSTA, GA 31601 (229) 244-6709 Fax (229) 244-7778 DATE July 2, 2010 JOB NO. 09-019 TO: BES Incorporated 2712 Bull Street Beaufort,

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable

More information

Learning Module 10: Loadcenters. 101 Basic Series

Learning Module 10: Loadcenters. 101 Basic Series Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

Section 3. Molded Case Circuit Breakers.

Section 3. Molded Case Circuit Breakers. Molded Case Circuit Breakers Section 3 Industrial Circuit Breakers How to Order...3-2 Features...3-4 Quick Reference Guide...3-5 Q-Line Circuit Breakers Plug-In 120/240V Class...3-11 Plug-In 240V Class...3-13

More information

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit reaker Selection Guide T H L 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC L = Plug-in

More information

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

Power Mod. Meter Stacks: WMM Residential Stacks. Residential Meter Stacks

Power Mod. Meter Stacks: WMM Residential Stacks. Residential Meter Stacks Meter Stacks: WMM Residential Stacks Residential Meter Stacks Power Mod s core offering of Residential Meter Stacks, type WMM, offers the widest product offering and flexibility in the industry. Each meter

More information