Section 3: Molded Case Circuit Breakers

Size: px
Start display at page:

Download "Section 3: Molded Case Circuit Breakers"

Transcription

1 Section : Molded Case Circuit Breakers Molded Case Circuit Breakers Features...-2 Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units Features...- Molded Case Circuit Breakers Quick Reference Guide...-4 Miniature Circuit Breakers and Supplementary Protectors: Plug-in Circuit Breakers 240V Class...-5 Bolt-on Circuit Breakers 240V Class Bolt-on Circuit Breakers 480/277V Class Cable-in Cable-out (lug-lug) 240V Class DIN-Rail Mount 240V Class Molded Case Switches...-2 E2000 Miniature Circuit Breakers EP60 Series EP100 Series EP100 UC Series Series CA Auxiliary Switch and Bell Alarm...-0 Shunt Trip and Undervoltage Release...-2 Technical Data...- Accessories...-4 Industrial Circuit Breakers Spectra RMS, Spectra RMS with MicroVersaTrip Plus Trip Units, Spectra RMS with MicroVersaTrip PM Trip Units, Thermal Magnetic and J/K with MicroVersaTrip RMS-9 and Power+ 4 Trip Units: How to Order...-7 MicroVersaTrip PM Trip Units Features MicroVersaTrip PM Trip Unit Characteristics MicroVersaTrip PM Trip Units How to Order R-Frame Molded Case Circuit Breakers How to Order...-4 Electric Trip Spectra RMS Breakers Quick Reference Guide Electric Trip Spectra RMS Breakers IEC/JIS Ratings Thermal Magnetic Trip Quick Reference Guide Molded Case Circuit Breakers Quick Reference Guide A Circuit Breakers, Electronic Trip, Spectra RMS A Circuit Breakers, Thermal-Magnetic Trip, E150 Line A Circuit Breakers, Electronic Trip, Spectra RMS A Circuit Breakers, Thermal-Magnetic Trip, F225 Line A Circuit Breakers, Thermal-Magnetic Trip, Q Line A Circuit Breakers, Electronic Trip, Spectra RMS A Circuit Breakers, Electronic Trip, Spectra RMS A Circuit Breakers, Electronic Trip, Spectra RMS with MicroVersaTrip PM Trip Units A Circuit Breakers, Thermal-Magnetic Trip, J600 Line A Circuit Breakers, Electronic Trip, Spectra RMS A Circuit Breakers, Electronic Trip, Spectra RMS with MicroVersaTrip Plus and PM A Circuit Breakers, Thermal-Magnetic Trip, K1200 Line A Circuit Breakers, Electronic Trip R Frame A Molded Case Switches, Spectra RMS A, Motor Circuit Protectors, Spectra RMS A, Mine Duty Circuit Breakers, Standard Duty Replacement Breakers, TriBreak, Internally Fused Replacement Breakers, THLC Current Limiting, Unfused Replacement Breakers, J and K Frame Circuit Breakers with MicroVersa Trip Trip Units Replacement Breakers, J and K Frame Circuit Breakers with Power+ 4 Trip Units Internal Accessories Spectra RMS Circuit Breakers...-8 Molded Case Circuit Breakers Internally Mounted Signaling and Controlling Functions External Accessories Cable Operators Handle Operators...-9 Flange-Mounted Operators Door-Mounted Operators Motor Operators and Plug-in Hardware Mechanical Interlocks and Locking Devices Breaker Mounting Hardware and Kits Lugs and Associated Hardware Neutral Grounds and Sensors Plug-in Hardware R Frame Accessories Power Management System Accessories Spectra RMS Accessories Other Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -1

2 Molded Case Circuit Breakers Features Spectra RMS Molded Case Circuit Breakers SE150, SF250, SG600, and SK1200 circuit breaker frames have a digital, solid-state, rms sensing trip system with field installable, front-mounted rating plugs to establish or change the breaker ampere rating. Adjustable instantaneous with tracking short-time is standard on all frames including SE150. The trip system uses digital sampling to determine the rms value of sinusoidal and nonsinusoidal currents. MicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Units SG600 and SK1200 are optionally available with either MicroVersaTrip Plus or MicroVersaTrip PM trip units which offer expanded functionality in the same space-saving size of standard Spectra RMS breakers. The trip system uses digital sampling to determine the rms value of sinusoidal and nonsinusoidal currents. MicroVersaTrip Plus Trip Units MicroVersaTrip Plus trip units utilize a digital, LCD display with a four-button keypad to provide local set-up and readout of trip settings. A -phase ammeter and trip indicators are standard, as is a clear plastic cover with provisions for sealing to allow tamperresistant installation. The trip unit digitally measures the current waveform in each phase to determine the true rms value of the current, regardless of the waveshape. MicroVersaTrip Plus trip units provide accurate, predictable overload and short-circuit protection for distribution systems that include ac and dc variable speed drives, rectifiers, induction heating, and other loads that cause high harmonic distortion as well as standard circuit. They provide maximum breaker-to-breaker selectivity and custom load protection. Short-time and ground fault functions include the flexibility of coordination with or without an I 2 t ramp. MicroVersaTrip PM Trip Unit The MicroVersaTrip PM trip unit adds power management system capability, advanced metering, and protective relays to the basic functions of the MicroVersaTrip Plus trip unit. The MicroVersaTrip PM trip unit communicates directly on the GE POWER LEADER communication bus. A complete circuit breaker consists of a UL listed circuit breaker frame and a rating plug (UL listed interchangeable trip unit). Terminal lugs for cable connection are available if required. All frames use the same UL listed, field-installable internal accessories (auxiliary switch, shunt trip, undervoltage release and bell alarm). All frame sizes have maximum UL listed interrupting ratings of Vac and Vac with 600 Vac ratings to 65 ka depending on frame size. UL listed current limiting versions are provided through the SG600 frame for the Vac and the Vac models, with no increase in physical frame size. Spectra RMS Mag-Break instantaneous-only motor circuit protectors also use the same digital, solid-state trip unit and rating plugs as the circuit breakers. The interchangeable rating plug establishes the instantaneous pickup range (with tracking short-time) but does not change the frame ampere rating. Spectra RMS molded case switches have a fixed, high-set instantaneous trip (without tracking short-time function) and have short-circuit withstand ratings equal to their equivalent breaker frame size interrupting rating in most cases. Spectra RMS breakers are ambient insensitive. Trip times will not vary over the range C breaker ambient. Refer to GET-7002 for further application information. Spectra RMS breakers contain no parts that would support fungus growth and are, therefore, inherently fungusproof. Other MCCB Features UL489 Listed Broad product line to meet virtually any application need. Reduced downtime. A tripped breaker is easily spotted and can be immediately reset after the fault has been corrected. Eliminates single phasing. A common trip bar disconnects all poles simultaneously on both overloads and short circuits. Offers application flexibility through the use of a wide variety of accessory devices and special attachments. Repetitive operation no fuses to replace. Breakers can be repetitively tested. Fuses must be destroyed to confirm calibration accuracy. For more information on these products, order publications listed in Sections 21 and 22. Reference Publications Spectra RMS Molded Case Circuit Breakers GEH-5591 SE150 & SF250 GEH-566 SG600 SG600 with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units GEH-5592 SK1200 SK1200 with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units GEH-594 MicroVersaTrip Plus and MicroVersaTrip PM Trip Units in Spectra RMS Molded Case Circuit Breakers GEH-5887 Micro-VersaTrip Plus and MicroVersaTrip PM Rating Plugs GEH-5549 Standard Rating Plugs GEH-5551 Shunt Trip/UV Release GEH-559 Auxiliary Switch/Bell Alarm GEH-5885 R-Frame Molded Case Circuit Breakers DEJ-001 TVPBP Portable Battery Pack GEH-6250 Voltage Module GEH-6251 Power Supply Plate GEH-6252 Voltage Conditioner Plate GEH-625 Power Supply Assembly GEH-6254 Voltage Conditioner Assembly GEH-6255 Distribution Cable Harness GEH-6256 Distribution Cable Extension GEH-6257 Distribution Cable Terminal Block GEH-6258 Distribution Cable Junction Box NOTE: NEMA ABI (1975) has been superceded by UL489-2 BuyLog Catalog Rev. 12/04 distributed by AA Electric

3 Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units Features MicroVersaTrip Plus Trip Units Standard -phase Ammeter with ±4% accuracy. Adjustable Long Time (L) pickup, X, and delay (-4 bands). Adjustable Instantaneous (I) pickup, X. Local Overload and Short Circuit Trip Indicators (T) with overload pickup warning. Interchangeable trip ratings plugs with test set jack for TVRMS test set. Digital LCD display with four-button keypad for function selection and set point adjustment and sealable, clear Lexan cover for tamper-resistant settings. True rms sensing for accurate response to high harmonic content waveforms. EMI immunity per ANSI C7.90. Optional Adjustable Short-Time (S) pickup, C, and delay (4 bands) with I 2 t IN/OUT selection. Adjustable Ground fault (G) pickup, S, and delay (4 bands) with I 2 t IN/OUT selection and trip indicator. The 4 short-time and ground fault delay bands provide broader system selectivity. World Standards Frames rated to UL, CSA, IEC 947-2, and JIS. Universal Internal Accessories Uses the same front-mounted, field installable shunt trips, undervoltage releases, bell alarms, and auxiliary switches as standard Spectra RMS breakers. Accessory Lead Routing Left or Right Side channels mean no extra space required for accessory leads. Current Limiting SE150, SF250 and SG600 frames rated 65kA and 480 Vac are UL listed as current limiting. Reverse Feed Front-mounted interchangeable rating plugs mean all frames are UL listed for reverse feed. SG Frame with MicroVersaTrip Plus Trip Unit Wide Current Setting Range Interchangeable rating plugs combined with 5 current sensors and X long time pickup yield ampere ratings from 0 to 1200A. 100% Continuous Current Rated Optionally available for 100% UL continuous current rating applications. Control Power 24 Vdc Optionally available, provides connection capability for +24 Vdc into the breaker via the distribution cable system. MicroVersaTrip Plus Trip Unit Characteristics 1 Current Setting (C) (Pick-Up) (Multiple of Rating Plug Amperes) (X) 0.5 to 1.0 in increments of 0.05 Long-Time 2 Delay (Seconds) 2.4, 4.9, 9.8, 20,4 Pick-Up (Multiple of Current Setting) (C) 1.5 to 9.0 in increments of 0.5 Short-Time Delay (Seconds) I 2 t in; 4.44 I 2 t out; 6.10,.20,.0,.40 Adjustable Instantaneous Pick-Up (Multiple of Rating Plug Amperes) (X) 1.5 to 10.0 in increments of 0.5 Pick-Up (Multiple of Sensor Ampere Rating) (X).20 to 1.00 in increments of.05 X = Rating Plug Amperes S = Sensor Ampere Rating C = Long-Time Current Settings (Pick-Up) 1 Contact local GE Sales Office for use on 400 Hz applications. Not UL listed for 400 Hz. 2 Pick-up fixed at 1.1C. 20 second delay (band) not available on SG frames. 4 Time delay at 600% of current setting at lower limit of each band. 5 Time delay at 200% of pick-up setting at lower limit of band. 6 Time delay shown at lower limit of each band. Pick-up tolerances ± 10%. Ground fault pick-up not to exceed 1200 amperes. Ground Fault Delay (Seconds) I 2 t in; 5.41 I 2 t out; 6.10,.20,.0,.40 Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -

4 Molded Case Circuit Breakers Quick Reference Guide Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage. Q Line (UL file E-11592; Fixed Thermal Magnetic Trip Unit) Circuit Breaker Type ac dc / H W D A B C E / /4 10 TQ 2 / / /2 5 THQP / /2 1/2 2 / TQL/TQB/ 120/ /2 2 /8 TQC THQL 1 120/ THQB /2 2 2 /8 25 THQC THHQB 1 THHQC / /2 2 2 / / THHQL /2 2 2 / TXQL 1 120/ TXQB /2 2 2 /8 25 TXQC TQDL / / /8 12 THQDL / / /8 12 TQD 1 THQD / /16 2 5/8 2 7/16 2 7/16 27/ /8 11/ / /16 2 5/8 2 7/16 2 7/16 27/ /8 11/16 1 TJD /8 8 1/4 1/16 15/16 1/16 1 /8 1 / TEY /4 2 1/16 480/ THQB THQC THQL...GF, GFEP, AF /2 2 / / THHQL...GF THHQB...GF, GFEP, AF /2 1 2 /8 10 1UL listed as HACR (heating, air conditioning and refrigeration). 2 Not UL listed. 480Y/277 Vac Ampere Rating No. Poles Maximum Voltage Rating UL Listed Interrupting Ratings rms Symmetrical ka Vac Vdc Dimensions (in.) CB Ground Fault, Equipment Ground Fault and Arc Fault (UL File E-51075; Fixed Thermal Magnetic Trip Unit) Std. Pack -4 BuyLog Catalog Rev. 12/04 distributed by AA Electric

5 Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class TQL and THQL 120/240 Vac GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA TQL1110 $ kA (1) 14-8 Cu/12-8 Al THQL1115 $ kA (1) 14-8 Cu/12-8 Al THQL1120 $ kA (1) 14-8 Cu/12-8 Al THQL1125 $ kA (1) 14-8 Cu/12-8 Al THQL110 $ kA (1) 8- Cu/8- Al THQL115 $ kA (1) 8- Cu/8- Al THQL1140 $ kA (1) 8- Cu/8- Al THQL1145 $ kA (1) 8- Cu/8- Al THQL1150 $ kA (1) 8- Cu/8- Al THQL1160 $ kA (1) 6-1/0 Cu/4-1/0 Al THQL1170 $42.50 THQL1120 TQL and THQL 120/240 Vac, Internal Common Trip GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA TQL2110 $ kA (1) 14-8 Cu/12-8 Al THQL2115 $ kA (1) 14-8 Cu/12-8 Al THQL2120 $ kA (1) 14-8 Cu/12-8 Al THQL2125 $ kA (1) 14-8 Cu/12-8 Al THQL210 $ kA (1) 8- Cu/8- Al THQL215 $ kA (1) 8- Cu/8- Al THQL2140 $ kA (1) 8- Cu/8- Al THQL2145 $ kA (1) 8- Cu/8- Al THQL2150 $ kA (1) 8- Cu/8- Al THQL2160 $ kA (1) 6-1/0 Cu/4-1/0 Al THQL2170 $ kA (1) 6-1/0 Cu/4-1/0 Al THQL2180 $ kA (1) 6-1/0 Cu/4-1/0 Al THQL2190 $ kA (1) 6-1/0 Cu/4-1/0 Al THQL21100 $ kA (1) 2-2/0 Cu/2-2/0 Al THQL21110 $ kA (1) 2-2/0 Cu/2-2/0 Al THQL21125 $ THQP 120/240 Vac GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQP115 $ kA 14-8 Cu/12-8 Al THQP120 $ kA 14-8 Cu/12-8 Al THQP125 $ kA 8-4 Cu/8-4 Al THQP10 $ kA 8-4 Cu/8-4 Al THQP15 $ kA 8-4 Cu/8-4 Al THQP140 $ kA 8-4 Cu/8-4 Al THQP145 $ kA 8-4 Cu/8-4 Al THQP150 $ Solid or stranded for AWG. 2 UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. Recommended for use as main or submain breaker only. UL listed as HACR (heating, air conditioning and refrigeration). Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -5

6 Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THQP 120/240 Vac, Internal Common Trip GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQP215 $ kA 14-8 Cu/12-8 Al THQP220 $ kA 14-8 Cu/12-8 Al THQP225 $ kA 8-4 Cu/8-4 Al THQP20 $ kA 8-4 Cu/8-4 Al THQP25 $ kA 8-4 Cu/8-4 Al THQP240 $ kA 8-4 Cu/8-4 Al THQP245 $ kA 8-4 Cu/8-4 Al THQP250 $ ampere UL Listed as HACR (heating, air conditioning and refrigeration). TQL and THQL 120/240 Vac, Internal Common Trip GO-18 # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA TQL22010 $ kA 14-8 Cu/12-8 Al THQL22015 $ kA 14-8 Cu/12-8 Al THQL22020 $ kA 14-8 Cu/12-8 Al THQL22025 $ kA 14-8 Cu/12-8 Al THQL2200 $ kA 8- Cu/8- Al THQL2205 $ kA 8- Cu/8- Al THQL22040 $ kA 8- Cu/8- Al THQL22045 $ kA 8- Cu/8- Al THQL22050 $ kA 8- Cu/8- Al THQL22060 $ kA 6-1/0 Cu/4-1/0 Al THQL22070 $ kA 6-1/0 Cu/4-1/0 Al THQL22080 $ kA 6-1/0 Cu/4-1/0 Al THQL22090 $ kA 6-1/0 Cu/4-1/0 Al THQL22100 $ TQL and THQL 240 Vac, Internal Common Trip GO-18 # of Ampere 240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price 10 5kA TQL2010 $ kA 14-8 Cu/12-8 Al THQL2015 $ kA 14-8 Cu/12-8 Al THQL2020 $ kA 14-8 Cu/12-8 Al THQL2025 $ kA 14-8 Cu/12-8 Al THQL200 $ kA 8- Cu/8- Al THQL205 $ kA 8- Cu/8- Al THQL2040 $ kA 8- Cu/8- Al THQL2045 $ kA 8- Cu/8- Al THQL2050 $ kA 8- Cu/8- Al THQL2060 $ kA 6-1/0 Cu/4-1/0 Al THQL2070 $ kA 6-1/0 Cu/4-1/0 Al THQL2080 $ kA 6-1/0 Cu/4-1/0 Al THQL2090 $ kA 6-1/0 Cu/4-1/0 Al THQL2100 $ THQL and THHQL 120 Vac Arc Fault GO-146A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA Cu/14-10 Al THQL1115AF $ kA Cu/14-10 Al THQL1120AF $ kA Cu/14-10 Al THHQL1115AF $ kA Cu/14-10 Al THHQL1120AF $26.00 THQP20 THQL2015 THQL1115AF THQL and THHQL 120/240 Vac Arc Fault GO-146A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA Cu/14-10 Al THQL2115AF $ kA Cu/14-10 Al THQL2120AF $ kA Cu/14-10 Al THHQL2115AF $ kA Cu/14-10 Al THHQL2120AF $ Solid or stranded for AWG. THQL2115AF -6 BuyLog Catalog Rev. 12/04 distributed by AA Electric

7 Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THQL and THHQL 120 Vac, Ground Fault Circuit Interrupters GO-146 # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQL1115GF $ kA 14-8 Cu/12-8 Al THQL1120GF $ kA 14-8 Cu/12-8 Al THQL110GF $ kA 14-8 Cu/12-8 Al THHQL1115GF $ kA 14-8 Cu/12-8 Al THHQL1120GF $ kA 14-8 Cu/12-8 Al THHQL110GF $11.00 THQL and THHQL 120/240 Vac or 208Y/120 Vac, Ground Fault Circuit Interrupters Internal Common Trip GO-146 # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQL2115GF1 $ kA 14-8 Cu/12-8 Al THQL2120GF1 $ kA 14-8 Cu/12-8 Al THQL210GF1 $ kA 8- Cu/8- Al THQL2140GF1 $ kA 8- Cu/8- Al THQL2150GF1 $ THQL and THHQL 120 Vac, Equipment Protection Ground Fault Circuit Breakers Internal Common Trip GO-146 # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQL1115GFEP $ kA 14-8 Cu/12-8 Al THQL1120GFEP $ kA 14-8 Cu/12-8 Al THQL110GFEP $ THQL1120GF THQL and THHQL 120/240 Vac or 208Y/120 Vac, Equipment Protection Ground Fault Circuit Breakers GO-146 # of Ampere 120/240 Vac or 208Y/120 Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQL2115GFEP $ kA 14-8 Cu/12-8 Al THQL2120GFEP $ kA 14-8 Cu/12-8 Al THQL210GFEP $ THQL Interlocking for use in PowerMark Gold Generator Panels GO-18A # of Ampere 120/240 Vac or 208Y/120 Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQL210GEN $ kA 8- Cu/8- Al THQL2160GEN $28.75 Two breakers required for interlocking. TQ Circuit Breakers 120/240 Vac /4 UL Classified Circuit Breakers for use in Square D QO Load Centers. 10 kaic RMS symmetrical. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 GO-18Q # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TQ1115 $ kA 14-8 Cu/12-8 Al TQ1120 $ kA 14-8 Cu/12-8 Al TQ110 $ kA 8-2 Cu/8-2 Al TQ1140 $ kA 8-2 Cu/8-2 Al TQ1150 $ kA 14-8 Cu/12-8 Al TQ2115 $ kA 14-8 Cu/12-8 Al TQ2120 $ kA 14-8 Cu/12-8 Al TQ210 $ kA 8-2 Cu/8-2 Al TQ2140 $ kA 8-2 Cu/8-2 Al TQ2150 $ kA 8-2 Cu/8-2 Al TQ2160 $ Solid or stranded for AWG. BuyLog Catalog -7

8 Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THQL and THHQL 120/240 Vac, High Intensity Discharge Lighting Loads GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQL1115HID 2 $ kA 14-8 Cu/12-8 Al THQL1120HID 2 $ kA 14-8 Cu/12-8 Al THQL1125HID $ kA 14-8 Cu/12-8 Al THQL110HID $ kA 14-8 Cu/12-8 Al THHQL1115HID 2 $ kA 14-8 Cu/12-8 Al THHQL1120HID 2 $ kA 14-8 Cu/12-8 Al THHQL1125HID $ kA 14-8 Cu/12-8 Al THHQL110HID $49.50 UL listed as HID. THQL2120HID THQL and THHQL 120/240 Vac, Internal Common Trip For High Intensity Discharge Lighting Loads GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQL2115HID $ kA 14-8 Cu/12-8 Al THQL2120HID $ kA 14-8 Cu/12-8 Al THQL2125HID $ kA 14-8 Cu/12-8 Al THQL210HID $ kA 14-8 Cu/12-8 Al THHQL2115HID $ kA 14-8 Cu/12-8 Al THHQL2120HID $ kA 14-8 Cu/12-8 Al THHQL2125HID $ kA 14-8 Cu/12-8 Al THHQL210HID $ UL listed as HID. THQL 120/240 Vac, High In-Rush Loads GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQL1115HM $ kA 14-8 Cu/12-8 Al THQL1120HM $ kA 14-8 Cu/12-8 Al THQL1125HM $ kA 14-8 Cu/12-8 Al THQL110HM $ kA 8- Cu/8- Al THQL1140HM $ kA 8- Cu/8- Al THQL1150HM $26.75 THQL 120 Vac, For Factory Installed Shunt Trip,4 Internal Common Trip GO-18 # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price 20 10kA 14-8 Cu/12-8 Al THQL2020ST1 $27.00 THQL1120HM THQL 120/240 Vac, Thermal Magnetic Pole plus Nonautomatic Pole For Switching Neutral GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQL21WY15 $ kA 14-8 Cu/12-8 Al THQL21WY20 $ kA 14-8 Cu/12-8 Al THQL21WY25 $ kA 14-8 Cu/12-8 Al THQL21WY0 $ kA 14-8 Cu/12-8 Al THQL1WY15 $ kA 14-8 Cu/12-8 Al THQL1WY20 $ kA 14-8 Cu/12-8 Al THQL1WY25 $ kA 14-8 Cu/12-8 Al THQL1WY0 $ Solid or stranded for AWG. 2 UL listed as SWD (switching duty). Suitable for 120 Vac fluorescent lighting loads. For additional shunt trip offerings see page ampere are UL listed as HACR (heating, air conditioning and refrigeration). -8 BuyLog Catalog Rev. 12/04 distributed by AA Electric

9 Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THQMV Top-Feed Main Circuit Breaker Kits for use with 150A-225A PowerMark Gold Load Centers GO-18M # of Ampere Interrupting Rating Poles System Voltage Wire Range 1 Product Number List Price kA 6-50 Cu/Al THQMV100 $ kA 6-50 Cu/Al THQMV125 $ kA 6-50 Cu/Al THQMV150 $ kA 6-50 Cu/Al THQMV175 $ kA 6-50 Cu/Al THQMV200 $ kA 6-50 Cu/Al THQMV225 $ THQMV200 THQMV Bottom-Feed Main Circuit Breaker Kits for use with 150A-225A PowerMark Gold Load Centers Internal Common Trip GO-18M # of Ampere Interrupting Rating Poles System Voltage Wire Range 1 Product Number List Price kA 6-50 Cu/Al THQMV100B $ kA 6-50 Cu/Al THQMV125B $ kA 6-50 Cu/Al THQMV150B $ kA 6-50 Cu/Al THQMV175B $ kA 6-50 Cu/Al THQMV200B $ kA 6-50 Cu/Al THQMV225B $ THQMV200B THLK Sub-free and Feed-through Lugs Internal Common Trip GO-17A # of Ampere Poles Rating Wire Range 1 Product Number List Price /0 Cu/Al THLK2125 $ /0 Cu/Al THLK125 $ /0 Cu/Al THLK $ Cu/Al THLK $ Cu/Al THLK225 $ TQDL 120/240 Vac, Internal Common Trip GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 1/0-250 Cu/Al TQDL21125 $ kA 1/0-250 Cu/Al TQDL21150 $ kA 1/0-250 Cu/Al TQDL21175 $ kA 1/0-250 Cu/Al TQDL21200 $ Solid or stranded for AWG. 2 For use with PowerMark Gold load centers only. For use with three-phase load centers only. Includes mounting base. UL listed as HACR (heating, air conditioning and refrigeration). Requires four one-inch spaces. THLK2125 THKL2150 TQDL21200 THQP10 Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -9

10 Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THHQL 120 Vac GO-18A # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQL $ kA 14-8 Cu/12-8 Al THHQL $ kA 14-8 Cu/12-8 Al THHQL1125 $ kA 8- Cu/8- Al THHQL110 $ kA 8- Cu/8- Al THHQL115 $ kA 8- Cu/8- Al THHQL1140 $ kA 8- Cu/8- Al THHQL1145 $ kA 8- Cu/8- Al THHQL1150 $ kA 8- Cu/8- Al THHQL1160 $ kA 6-1/0 Cu/4-1/0 Al THHQL1170 $58.50 THHQL1120 THHQL 120/240 Vac, Internal Common Trip GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQL2115 $ kA 14-8 Cu/12-8 Al THHQL2120 $ kA 14-8 Cu/12-8 Al THHQL2125 $ kA 8- Cu/8- Al THHQL210 $ kA 8- Cu/8- Al THHQL215 $ kA 8- Cu/8- Al THHQL2140 $ kA 8- Cu/8- Al THHQL2145 $ kA 8- Cu/8- Al THHQL2150 $ kA 8- Cu/8- Al THHQL2160 $ kA 6-1/0 Cu/4-1/0 Al THHQL2170 $ kA 6-1/0 Cu/4-1/0 Al THHQL2180 $ kA 6-1/0 Cu/4-1/0 Al THHQL2190 $ kA 6-1/0 Cu/4-1/0 Al THHQL21100 $ kA 2-2/0 Cu/2-2/0 Al THHQL21110 $ kA 2-2/0 Cu/2-2/0 Al THHQL21125 $ Solid or stranded for AWG. 2 UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. UL listed HACR (heating, air conditioning and refrigeration). -10 BuyLog Catalog Rev. 12/04 distributed by AA Electric

11 Miniature Circuit Breakers and Supplementary Protectors Plug-in Circuit Breakers 240V Class THHQL 240 Vac, Internal Common Trip GO-18 # of Ampere 240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQL22015 $ kA 14-8 Cu/12-8 Al THHQL22020 $ kA 14-8 Cu/12-8 Al THHQL22025 $ kA 8- Cu/8- Al THHQL2200 $ kA 8- Cu/8- Al THHQL2205 $ kA 8- Cu/8- Al THHQL22040 $ kA 8- Cu/8- Al THHQL22045 $ kA 8- Cu/8- Al THHQL22050 $ kA 8- Cu/8- Al THHQL22060 $ kA 6-1/0 Cu/4-1/0 Al THHQL22070 $ kA 6-1/0 Cu/4-1/0 Al THHQL22080 $ kA 6-1/0 Cu/4-1/0 Al THHQL22090 $ kA 6-1/0 Cu/4-1/0 Al THHQL22100 $ kA 14-8 Cu/12-8 Al THHQL2015 $ kA 14-8 Cu/12-8 Al THHQL2020 $ kA 14-8 Cu/12-8 Al THHQL2025 $ kA 8- Cu/8- Al THHQL200 $ kA 8- Cu/8- Al THHQL205 $ kA 8- Cu/8- Al THHQL2040 $ kA 8- Cu/8- Al THHQL2045 $ kA 8- Cu/8- Al THHQL2050 $ kA 8- Cu/8- Al THHQL2060 $ kA 6-1/0 Cu/4-1/0 Al THHQL2070 $ kA 6-1/0 Cu/4-1/0 Al THHQL2080 $ kA 6-1/0 Cu/4-1/0 Al THHQL2090 $ kA 6-1/0 Cu/4-1/0 Al THHQL2100 $59.00 UL listed HACR (heating, air conditioning and refrigeration). THHQL2015 THQDL 120/240 Vac, Internal Common Trip GO-18 # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 1/0-250 Cu/1/0-250 Al THQDL21125 $ kA 1/0-250 Cu/1/0-250 Al THQDL21150 $ kA 1/0-250 Cu/1/0-250 Al THQDL21175 $ kA 1/0-250 Cu/1/0-250 Al THQDL21200 $71.00 TXQL 120/240 Vac GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TXQL $ kA 14-8 Cu/12-8 Al TXQL $ kA 14-8 Cu/12-8 Al TXQL1125 $ kA 14-8 Cu/12-8 Al TXQL110 $74.75 TXQL 120/240 Vac, Internal Common Trip GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TXQL2115 $ kA 14-8 Cu/12-8 Al TXQL2120 $ kA 14-8 Cu/12-8 Al TXQL2125 $ kA 14-8 Cu/12-8 Al TXQL210 $ kA 14-8 Cu/12-8 Al TXQL2015 $ kA 14-8 Cu/12-8 Al TXQL2020 $ kA 14-8 Cu/12-8 Al TXQL2025 $ kA 14-8 Cu/12-8 Al TXQL200 $ Solid or stranded for AWG. 2 UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. UL listed HACR (heating, air conditioning and refrigeration). Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -11

12 Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class TQB, THQB 120/240 Vac GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TQB1110 $ kA 14-8 Cu/12-8 Al THQB $ kA 14-8 Cu/12-8 Al THQB $ kA 14-8 Cu/12-8 Al THQB1125 $ kA 14-8 Cu/12-8 Al THQB110 $ kA 8- Cu/8- Al THQB115 $ kA 8- Cu/8- Al THQB1140 $ kA 8- Cu/8- Al THQB1145 $ kA 8- Cu/8- Al THQB1150 $ kA 8- Cu/8- Al THQB1160 $ kA 6-1/0 Cu/4-1/0 Al THQB1170 $8.00 THQB2115 TQB, THQB 120/240 Vac, Internal Common Trip GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TQB2110 $ kA 14-8 Cu/12-8 Al THQB2115 $ kA 14-8 Cu/12-8 Al THQB2120 $ kA 14-8 Cu/12-8 Al THQB2125 $ kA 14-8 Cu/12-8 Al THQB210 $ kA 8- Cu/8- Al THQB215 $ kA 8- Cu/8- Al THQB2140 $ kA 8- Cu/8- Al THQB2145 $ kA 8- Cu/8- Al THQB2150 $ kA 8- Cu/8- Al THQB2160 $ kA 8- Cu/8- Al THQB2170 $ kA 6-1/0 Cu/4-1/0 Al THQB2180 $ kA 6-1/0 Cu/4-1/0 Al THQB2190 $ kA 6-1/0 Cu/4-1/0 Al THQB21100 $11.00 TQB, THQB 240 Vac, Internal Common Trip GO-15B # of Ampere 240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TQB22010 $ kA 14-8 Cu/12-8 Al THQB22015 $ kA 14-8 Cu/12-8 Al THQB22020 $ kA 14-8 Cu/12-8 Al THQB22025 $ kA 14-8 Cu/12-8 Al THQB2200 $ kA 8- Cu/8- Al THQB2205 $ kA 8- Cu/8- Al THQB22040 $ kA 8- Cu/8- Al THQB22045 $ kA 8- Cu/8- Al THQB22050 $ kA 8- Cu/8- Al THQB22060 $ kA 6-1/0 Cu/4-1/0 Al THQB22070 $ kA 6-1/0 Cu/4-1/0 Al THQB22080 $ kA 6-1/0 Cu/4-1/0 Al THQB22090 $ kA 6-1/0 Cu/4-1/0 Al THQB22100 $ kA 14-8 Cu/12-8 Al TQB2010 $ kA 14-8 Cu/12-8 Al THQB2015 $ kA 14-8 Cu/12-8 Al THQB2020 $ kA 14-8 Cu/12-8 Al THQB2025 $ kA 14-8 Cu/12-8 Al THQB200 $ kA 8- Cu/8- Al THQB205 $ kA 8- Cu/8- Al THQB2040 $ kA 8- Cu/8- Al THQB2045 $ kA 8- Cu/8- Al THQB2050 $ kA 8- Cu/8- Al THQB2060 $ kA 6-1/0 Cu/4-1/0 Al THQB2070 $ kA 6-1/0 Cu/4-1/0 Al THQB2080 $ kA 6-1/0 Cu/4-1/0 Al THQB2090 $ kA 6-1/0 Cu/4-1/0 Al THQB2100 $ Solid or stranded for AWG. 2 UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. Not UL listed. UL listed HACR (heating, air conditioning and refrigeration). -12 BuyLog Catalog Rev. 12/04 distributed by AA Electric

13 Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class THQB, THHQB 120 Vac, Ground Fault Breakers (5 ma) GO-1 # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQB1115GF $ kA 14-8 Cu/12-8 Al THQB1120GF $ kA 14-8 Cu/12-8 Al THQB110GF $ kA 14-8 Cu/12-8 Al THHQB1115GF $ kA 14-8 Cu/12-8 Al THHQB1120GF $ kA 14-8 Cu/12-8 Al THHQB110GF $25.00 THQB 120/240 or 208Y/120 Vac, Ground Fault Breakers (5 ma), Internal Common Trip GO-1 # of Ampere 120/240 or 208Y/120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQB2115GF $ kA 14-8 Cu/12-8 Al THQB2120GF $ kA 14-8 Cu/12-8 Al THQB210GF $ THQB 120 Vac, Equipment Protection Ground Fault Circuit Breakers (0 ma) GO-1 # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQB1115GFEP $ kA 14-8 Cu/12-8 Al THQB1120GFEP $ kA 14-8 Cu/12-8 Al THQB110GFEP $ THQB1115GF THQB 120/240 or 208Y/120 Vac, Ground Fault Breakers Equipment Protection (0 ma) Ground Fault Circuit Breakers, Internal Common Trip GO-1 # of Ampere 120/240 or 208Y/120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQB2115GFEP $ kA 14-8 Cu/12-8 Al THQB2120GFEP $ kA 14-8 Cu/12-8 Al THQB210GFEP $27.00 THQB 120/240 Vac, High Intensity Discharge Lighting Loads GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQB1115HID 2 $ kA 14-8 Cu/12-8 Al THQB1120HID 2 $ kA 14-8 Cu/12-8 Al THQB1125HID $ kA 14-8 Cu/12-8 Al THQB110HID $2.75 UL listed as HID (high intensity discharge). THHQB 120/240 Vac, High Intensity Discharge Lighting Loads GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQB1115HID 2 $ kA 14-8 Cu/12-8 Al THHQB1120HID 2 $ kA 14-8 Cu/12-8 Al THHQB1125HID $ kA 14-8 Cu/12-8 Al THHQB110HID $ Solid or stranded for AWG. 2 UL listed as SWD (switching duty). Suitable for switching 120 Vac fluorescent lighting loads. UL listed as HID (high intensity discharge). Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -1

14 Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class THQB 120/240 Vac, Internal Common Trip, High Intensity Discharge Lighting Loads GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQB2115HID $ kA 14-8 Cu/12-8 Al THQB2120HID $ kA 14-8 Cu/12-8 Al THQB2125HID $ kA 14-8 Cu/12-8 Al THQB210HID $52.50 UL listed as HID THHQB 120/240 Vac, Internal Common Trip, High Intensity Discharge Lighting Loads GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQB2115HID $ kA 14-8 Cu/12-8 Al THHQB2120HID $ kA 14-8 Cu/12-8 Al THHQB2125HID $ kA 14-8 Cu/12-8 Al THHQB210HID $98.50 UL listed as HID THQB 120 Vac with Factory Installed 120 Vac Shunt Trip 2, GO-15B # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQB1120ST1 $11.00 THQB 120 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip 2, GO-15B # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQB2120ST1 $ kA 14-8 Cu/12-8 Al THQB210ST1 $ kA 6-1/0 Cu/4-1/0 Al THQB21100ST1 $ kA 14-8 Cu/12-8 Al THQB2020ST1 $ kA 14-8 Cu/12-8 Al THQB200ST1 $ kA 8- Cu/8- Al THQB2040ST1 $ kA 8- Cu/8- Al THQB2050ST1 $ kA 8- Cu/8- Al THQB2060ST1 $ kA 6-1/0 Cu/4-1/0 Al THQB2070ST1 $ kA 6-1/0 Cu/4-1/0 Al THQB2080ST1 $ kA 6-1/0 Cu/4-1/0 Al THQB2090ST1 $ kA 6-1/0 Cu/4-1/0 Al THQB2100ST1 $ THQB 120 Vac with Switching Neutral Single Thermal Magnetic Pole; Single Nonautomatic Pole GO-18A # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQB21WY15 $ kA 14-8 Cu/12-8 Al THQB21WY20 $ kA 14-8 Cu/12-8 Al THQB21WY25 $ kA 14-8 Cu/12-8 Al THQB21WY0 $58.50 THQB 120 Vac with Switching Neutral Two Thermal Magnetic Pole; Single Nonautomatic Pole GO-15B # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price 15 10kA 14-8 Cu/12-8 Al THQB1WY15 $ kA 14-8 Cu/12-8 Al THQB1WY20 $ kA 14-8 Cu/12-8 Al THQB1WY25 $ kA 14-8 Cu/12-8 Al THQB1WY0 $ Solid or stranded for AWG. 2 For additional shunt trip offerings see page ampere are UL listed as HACR (heating, air conditioning and refrigeration). -14 BuyLog Catalog Rev. 12/04 distributed by AA Electric

15 Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class THHQB 120/240 Vac GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQB $ kA 14-8 Cu/12-8 Al THHQB $ kA 14-8 Cu/12-8 Al THHQB1125 $ kA 14-8 Cu/12-8 Al THHQB110 $ kA 8- Cu/8- Al THHQB115 $ kA 8- Cu/8- Al THHQB1140 $ kA 8- Cu/8- Al THHQB1145 $ kA 8- Cu/8- Al THHQB1150 $ kA 8- Cu/8- Al THHQB1160 $ kA 6-1/0 Cu/4-1/0 Al THHQB1170 $51.00 THHQB2115 THHQB 120/240 Vac, Internal Common Trip GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQB2115 $ kA 14-8 Cu/12-8 Al THHQB2120 $ kA 14-8 Cu/12-8 Al THHQB2125 $ kA 14-8 Cu/12-8 Al THHQB210 $ kA 8- Cu/8- Al THHQB215 $ kA 8- Cu/8- Al THHQB2140 $ kA 8- Cu/8- Al THHQB2145 $ kA 8- Cu/8- Al THHQB2150 $ kA 8- Cu/8- Al THHQB2160 $ kA 6-1/0 Cu/4-1/0 Al THHQB2170 $ kA 6-1/0 Cu/4-1/0 Al THHQB2180 $ kA 6-1/0 Cu/4-1/0 Al THHQB2190 $ kA 6-1/0 Cu/4-1/0 Al THHQB21100 $18.00 THHQB 240 Vac, Internal Common Trip GO-15B # of Ampere 240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQB22015 $ kA 14-8 Cu/12-8 Al THHQB22020 $ kA 14-8 Cu/12-8 Al THHQB22025 $ kA 14-8 Cu/12-8 Al THHQB2200 $ kA 8- Cu/8- Al THHQB2205 $ kA 8- Cu/8- Al THHQB22040 $ kA 8- Cu/8- Al THHQB22045 $ kA 8- Cu/8- Al THHQB22050 $ kA 8- Cu/8- Al THHQB22060 $ kA 6-1/0 Cu/4-1/0 Al THHQB22070 $ kA 6-1/0 Cu/4-1/0 Al THHQB22080 $ kA 6-1/0 Cu/4-1/0 Al THHQB22090 $ kA 6-1/0 Cu/4-1/0 Al THHQB22100 $ kA 14-8 Cu/12-8 Al THHQB2015 $ kA 14-8 Cu/12-8 Al THHQB2020 $ kA 14-8 Cu/12-8 Al THHQB2025 $ kA 14-8 Cu/12-8 Al THHQB200 $ kA 8- Cu/8- Al THHQB205 $ kA 8- Cu/8- Al THHQB2040 $ kA 8- Cu/8- Al THHQB2045 $ kA 8- Cu/8- Al THHQB2050 $ kA 8- Cu/8- Al THHQB2060 $ kA 6-1/0 Cu/4-1/0 Al THHQB2070 $ kA 6-1/0 Cu/4-1/0 Al THHQB2080 $ kA 6-1/0 Cu/4-1/0 Al THHQB2090 $ kA 6-1/0 Cu/4-1/0 Al THHQB2100 $ Solid or stranded for AWG. 2 UL listed as SWD (switching duty). Suitable for switching 120 Vac fluorescent lighting loads. UL listed HACR (heating, air conditioning and refrigeration). Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -15

16 Molded Case Circuit Breakers Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 240V Class TXQB 120/240 Vac GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TXQB $ kA 14-8 Cu/12-8 Al TXQB $ kA 14-8 Cu/12-8 Al TXQB1125 $ kA 14-8 Cu/12-8 Al TXQB110 $6.50 TXQB 120/240 Vac, Internal Common Trip GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TXQB2115 $ kA 14-8 Cu/12-8 Al TXQB2120 $ kA 14-8 Cu/12-8 Al TXQB2125 $ kA 14-8 Cu/12-8 Al TXQB210 $ TXQB 240 Vac, Internal Common Trip GO-15B # of Ampere 240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price 15 65kA 14-8 Cu/12-8 Al TXQB2015 $ kA 14-8 Cu/12-8 Al TXQB2020 $ kA 14-8 Cu/12-8 Al TXQB2025 $ kA 14-8 Cu/12-8 Al TXQB200 $ Solid or stranded for AWG. 2 UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. UL listed HACR (heating, air conditioning and refrigeration). -16 BuyLog Catalog Rev. 12/04 distributed by AA Electric

17 Miniature Circuit Breakers and Supplementary Protectors Bolt-on Circuit Breakers 480Y/277V Class The TEY is a one-inch wide per pole, compact, "bolt-on" circuit breaker for use on grounded 480Y/277 Vac systems. The bolt-on mounting base, shown in the accessory table on page -4, makes the TEY suitable for various applications as a lug-lug breaker. TEY 1 pole Vac; 240, 277 Vac GO-15B # of Ampere Poles Rating Wire Range 1 Product Number List Price Cu/12-10 Al TEY115 2, $ Cu/12-10 Al TEY120 2, $ Cu/12-10 Al TEY125 $ Cu/14-10 Al TEY10 $ Cu/14-10 Al TEY15 $ Cu/14-10 Al TEY140 $ Cu/14-10 Al TEY145 $ Cu/14-10 Al TEY150 $ Cu/14-10 Al TEY160 $ Cu/2-1/0 Al TEY170 $ Cu/2-1/0 Al TEY180 $ Cu/2-1/0 Al TEY190 $ Cu/2-1/0 Al TEY1100 $ and -pole TEY breakers TEY 2 pole 120/240, 240 Vac; Vac GO-15B # of Ampere Poles Rating Wire Range 1 Product Number List Price Cu/12-10 Al TEY215 $ Cu/12-10 Al TEY220 $ Cu/12-10 Al TEY225 $ Cu/14-10 Al TEY20 $ Cu/12-10 Al TEY25 $ Cu/14-10 Al TEY240 $ Cu/12-10 Al TEY245 $ Cu/14-10 Al TEY250 $ Cu/14-10 Al TEY260 $ Cu/2-1/0 Al TEY270 $ Cu/2-1/0 Al TEY280 $ Cu/2-1/0 Al TEY290 $ Cu/2-1/0 Al TEY2100 $52.00 TEY pole 120/240, 240 Vac; Vac GO-15B # of Ampere Poles Rating Wire Range 1 Product Number List Price Cu/12-10 Al TEY15 $ Cu/12-10 Al TEY20 $ Cu/12-10 Al TEY25 $ Cu/14-10 Al TEY0 $ Cu/12-10 Al TEY5 $ Cu/14-10 Al TEY40 $ Cu/12-10 Al TEY45 $ Cu/14-10 Al TEY50 $ Cu/14-10 Al TEY60 $ Cu/2-1/0 Al TEY70 $ Cu/2-1/0 Al TEY80 $ Cu/2-1/0 Al TEY90 $ Cu/2-1/0 Al TEY100 $ Solid or stranded for AWG. 2 Single-pole, 15 and 20 ampere breakers are also UL listed as switching duty breakers, suitable for switching 120, 240, or 277 Vac. UL listed HACR (Heating, Air Conditioning, Refrigeration). Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -17

18 Miniature Circuit Breakers and Supplementary Protectors Cable-in Cable-out (lug-lug) 240V Class TQC, THQC 120/240 Vac GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number 2 List Price kA 14-4 Cu/12-2 Al TQC1110WL $ kA 14-8 Cu/12-8 Al THQC1115WL,4 $ kA 14-8 Cu/12-8 Al THQC1120WL,4 $ kA 14-8 Cu/12-8 Al THQC1125WL $ kA 14-8 Cu/12-8 Al THQC110WL $ kA 8- Cu/8- Al THQC115WL $ kA 8- Cu/8- Al THQC1140WL $ kA 8- Cu/8- Al THQC1145WL $ kA 8- Cu/8- Al THQC1150WL $ kA 8- Cu/8- Al THQC1160WL $ kA 6-1/0 Cu/4-1/0 Al THQC1170WL $9.00 TQC, THQC 120/240 Vac, Internal Common Trip GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number 2 List Price kA 14-4 Cu/12-2 Al TQC2110WL $ kA 14-8 Cu/12-8 Al THQC2115WL $ kA 14-8 Cu/12-8 Al THQC2120WL $ kA 14-8 Cu/12-8 Al THQC2125WL $ kA 14-8 Cu/12-8 Al THQC210WL $ kA 8- Cu/8- Al THQC215WL $ kA 8- Cu/8- Al THQC2140WL $ kA 8- Cu/8- Al THQC2145WL $ kA 8- Cu/8- Al THQC2150WL $ kA 8- Cu/8- Al THQC2160WL $ kA 6-1/0 Cu/4-1/0 Al THQC2170WL $ kA 6-1/0 Cu/4-1/0 Al THQC2180WL $ kA 6-1/0 Cu/4-1/0 Al THQC2190WL $ kA 6-1/0 Cu/4-1/0 Al THQC21100WL $ TQC, THQC 240 Vac, Internal Common Trip GO-15B # of Ampere 240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number 2 List Price kA 14-4 Cu/12-2 Al TQC22010WL $ kA 14-8 Cu/12-8 Al THQC22015WL $ kA 14-8 Cu/12-8 Al THQC22020WL $ kA 14-8 Cu/12-8 Al THQC22025WL $ kA 14-8 Cu/12-8 Al THQC2200WL $ kA 8- Cu/8- Al THQC2205WL $ kA 8- Cu/8- Al THQC22040WL $ kA 8- Cu/8- Al THQC22045WL $ kA 8- Cu/8- Al THQC22050WL $ kA 8- Cu/8- Al THQC22060WL $ kA 6-1/0 Cu/4-1/0 Al THQC22070WL $ kA 6-1/0 Cu/4-1/0 Al THQC22080WL $ kA 6-1/0 Cu/4-1/0 Al THQC22090WL $ kA 6-1/0 Cu/4-1/0 Al THQC22100WL $ kA 14-4 Cu/12-2 Al TQC2010WL $ kA 14-8 Cu/12-8 Al THQC2015WL $ kA 14-8 Cu/12-8 Al THQC2020WL $ kA 14-8 Cu/12-8 Al THQC2025WL $ kA 14-8 Cu/12-8 Al THQC200WL $ kA 8- Cu/8- Al THQC205WL $ kA 8- Cu/8- Al THQC2040WL $ kA 8- Cu/8- Al THQC2045WL $ kA 8- Cu/8- Al THQC2050WL $ kA 8- Cu/8- Al THQC2060WL $ kA 6-1/0 Cu/4-1/0 Al THQC2070WL $ kA 6-1/0 Cu/4-1/0 Al THQC2080WL $ kA 6-1/0 Cu/4-1/0 Al THQC2090WL $ kA 6-1/0 Cu/4-1/0 Al THQC2100WL $ Solid or stranded for AWG. 2 Use additional suffix BP (THQC2020WLBP) for bulk pack of 48 poles. Carton weight 20 lbs ampere breakers only. Suitable for mounting on standard 5mm DIN Rail. Refer to table on page -21 for termination options. 4 UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. UL listed HACR (heating, air conditioning and refrigeration). Refer to Q Line accessories listed on pages -4 to BuyLog Catalog Rev. 12/04 distributed by AA Electric

19 Miniature Circuit Breakers and Supplementary Protectors Cable-in Cable-out (lug-lug) 240V Class THQC 120 Vac, Ground Fault Circuit Interrupter GO-1 # of Ampere 120 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THQC1115GF 2 $ kA 14-8 Cu/12-8 Al THQC1120GF 2 $ kA 14-8 Cu/12-8 Al THQC110GF 2 $ THHQC 120/240 Vac GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQC1115WL 4 $ kA 14-8 Cu/12-8 Al THHQC1120WL 4 $ kA 14-8 Cu/12-8 Al THHQC1125WL 4 $ kA 14-8 Cu/12-8 Al THHQC110WL 4 $ kA 8- Cu/8- Al THHQC115WL 4 $ kA 8- Cu/8- Al THHQC1140WL 4 $ kA 8- Cu/8- Al THHQC1145WL 4 $ kA 8- Cu/8- Al THHQC1150WL 4 $ kA 8- Cu/8- Al THHQC1160WL 4 $ kA 6-1/0 Cu/4-1/0 Al THHQC1170WL $52.00 THQC1120GF THHQC 120/240 Vac, Internal Common Trip GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQC2115WL 4 $ kA 14-8 Cu/12-8 Al THHQC2120WL 4 $ kA 14-8 Cu/12-8 Al THHQC210WL 4 $ kA 8- Cu/8- Al THHQC215WL 4 $ kA 8- Cu/8- Al THHQC2140WL 4 $ kA 8- Cu/8- Al THHQC2145WL 4 $ kA 8- Cu/8- Al THHQC2150WL 4 $ kA 8- Cu/8- Al THHQC2160WL 4 $ kA 6-1/0 Cu/4-1/0 Al THHQC2170WL $ kA 6-1/0 Cu/4-1/0 Al THHQC2180WL $ kA 6-1/0 Cu/4-1/0 Al THHQC2190WL $ kA 6-1/0 Cu/4-1/0 Al THHQC21100WL $ Solid or stranded for AWG. 2 Requires mounting plate. See page -4. Not suitable for use in GE column panels. Use additional suffix BP (THQC2020WLBP) for bulk pack of 48 poles. Carton weight 20 lbs amperes breakers only. 4 Suitable for mounting on standard 5mm DIN Rail. UL listed HACR (heating, air conditioning and refrigeration). Use Q Line mounting accessories listed on pages -4 to -6. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -19

20 Miniature Circuit Breakers and Supplementary Protectors Cable-in Cable-out (lug-lug) 240V Class THHQC 240 Vac, Internal Common Trip GO-15B # of Ampere 240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al THHQC22015WL $ kA 14-8 Cu/12-8 Al THHQC22020WL $ kA 14-8 Cu/12-8 Al THHQC22025WL $ kA 14-8 Cu/12-8 Al THHQC2200WL $ kA 8- Cu/8- Al THHQC2205WL $ kA 8- Cu/8- Al THHQC22040WL $ kA 8- Cu/8- Al THHQC22045WL $ kA 8- Cu/8- Al THHQC22050WL $ kA 8- Cu/8- Al THHQC22060WL $ kA 6-1/0 Cu/4-1/0 Al THHQC22070WL $ kA 6-1/0 Cu/4-1/0 Al THHQC22080WL $ kA 6-1/0 Cu/4-1/0 Al THHQC22090WL $ kA 6-1/0 Cu/4-1/0 Al THHQC22100WL $ kA 14-8 Cu/12-8 Al THHQC2015WL $ kA 14-8 Cu/12-8 Al THHQC2020WL $ kA 14-8 Cu/12-8 Al THHQC2025WL $ kA 14-8 Cu/12-8 Al THHQC200WL $ kA 8- Cu/8- Al THHQC205WL $ kA 8- Cu/8- Al THHQC2040WL $ kA 8- Cu/8- Al THHQC2045WL $ kA 8- Cu/8- Al THHQC2050WL $ kA 8- Cu/8- Al THHQC2060WL $ kA 6-1/0 Cu/4-1/0 Al THHQC2070WL $ kA 6-1/0 Cu/4-1/0 Al THHQC2080WL $ kA 6-1/0 Cu/4-1/0 Al THHQC2090WL $ kA 6-1/0 Cu/4-1/0 Al THHQC2100WL $14.00 TXQC 120/240 Vac GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TXQC1115WL $ kA 14-8 Cu/12-8 Al TXQC1120WL $ kA 14-8 Cu/12-8 Al TXQC1125WL $ kA 14-8 Cu/12-8 Al TXQC110WL $6.50 TXQC 120/240 Vac, Internal Common Trip GO-15B # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price kA 14-8 Cu/12-8 Al TXQC2115WL $ kA 14-8 Cu/12-8 Al TXQC2120WL $ kA 14-8 Cu/12-8 Al TXQC2125WL $ kA 14-8 Cu/12-8 Al TXQC210WL $ TXQC 240 Vac, Internal Common Trip GO-18A # of Ampere 120/240 Vac Poles Rating Interrupting Rating Wire Range 1 Product Number List Price 15 65kA 14-8 Cu/12-8 Al TXQC2015WL $ kA 14-8 Cu/12-8 Al TXQC2020WL $ kA 14-8 Cu/12-8 Al TXQC2025WL $ kA 14-8 Cu/12-8 Al TXQC200WL $ Solid or stranded for AWG. UL listed HACR (heating, air conditioning and refrigeration). Use Q Line mounting accessories listed on pages -4 to BuyLog Catalog Rev. 12/04 distributed by AA Electric

21 Miniature Circuit Breakers and Supplementary Protectors DIN-Rail Mount 240V Class Product Features Multi-terminal Configuration Breakers 5 mm DIN rail mounting Optional front/rear panel mounting kits THQCFMK, page -4. Optional load end terminal for up to (4) 0.25-inch quick connnects. Contact local GE sales office for ring terminal configurations not DIN rail compatible. THQC, THHQC 120/240 Vac GO-15B # of Ampere 120/240 Vac CC Suffix X2 Suffix Poles Rating Interrupting Rating Product Number List Price List Price Adder List Price Adder kA THQC1115LL 1 $ kA THQC1120LL 1 $ kA THQC1125LL $ kA THQC110LL $ kA THQC115LL $ kA THQC1140LL $ kA THQC1145LL $ kA THQC1150LL $ kA THQC1160LL $17.25 $4.00 $ kA THHQC1115LL $ kA THHQC1120LL $ kA THHQC1125LL $ kA THHQC110LL $ kA THHQC115LL $ kA THHQC1140LL $ kA THHQC1145LL $ kA THHQC1150LL $ kA THHQC1160LL $ A UL Listed HACR (heating, air conditioning and refrigeration) THQC, THHQC 120/240 Vac, Internal Common Trip GO-15B # of Ampere 120/240 Vac CC Suffix X2 Suffix Poles Rating Interrupting Rating Product Number List Price List Price Adder List Price Adder kA THQC2115LL 1 $ kA THQC2120LL 1 $ kA THQC2125LL $ kA THQC210LL $ kA THQC215LL $ kA THQC2140LL $ kA THQC2145LL $ kA THQC2150LL $ kA THQC2160LL $7.50 $8.00 $ kA THHQC2115LL $ kA THHQC2120LL $ kA THHQC2125LL $ kA THHQC210LL $ kA THHQC215LL $ kA THHQC2140LL $ kA THHQC2145LL $ kA THHQC2150LL $ kA THHQC2160LL $ A UL Listed HACR (heating, air conditioning and refrigeration) Terminal Configuration Suffix 2 Line Terminal Load Terminal WL TQALA THQEL X2 TQALA N/A LL N/A N/A CC TQALA THQECC None N/A THQEL 1 15 and 20 ampere breakers UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. 2 Use additional suffix BP (THQC1120CCBP) for bulk pack of 48 poles. Must be ordered in multiples of 48 poles. Additional Q Line mounting accessories listed on pages -4 to -6. Terminal Selection GO-15B Type Wire Range Product Number List Price Lug Line only 14-6 Cu/12-2 Al TQALA $1.50 Lug Load only 14-2 Cu/12-2 Al THQEL $1.50 Quick Connector Load only (4) 14 Cu or (4) 12 Al THQECC $2.50 Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -21

22 Miniature Circuit Breakers and Supplementary Protectors Cable-in Cable-out (lug-lug) 240V Class TQD 240 Vac, Internal Common Trip GO-15F # of Ampere 240 Vac Poles Rating Interrupting Rating Product Number 1,2 List Price kA TQD22100WL $ kA TQD22125WL $ kA TQD22150WL $ kA TQD22175WL $ kA TQD22200WL $ kA TQD22225WL $ kA TQD2100WL $ kA TQD2125WL $ kA TQD2150WL $ kA TQD2175WL $ kA TQD2200WL $ kA TQD2225WL $ TQD 240 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip GO-15F # of Ampere 240 Vac Poles Rating Interrupting Rating Product Number 1,2 List Price kA TQD2125ST1 $ kA TQD2150ST1 $ kA TQD2175ST1 $ kA TQD2200ST1 $ kA TQD2225ST1 $79.00 THQD 240 Vac, Internal Common Trip GO-15F # of Ampere 240 Vac Poles Rating Interrupting Rating Product Number 1,2 List Price kA THQD22100WL $ kA THQD22125WL $ kA THQD22150WL $ kA THQD22175WL $ kA THQD22200WL $ kA THQD22225WL $ kA THQD2100WL $ kA THQD2125WL $ kA THQD2150WL $ kA THQD2175WL $ kA THQD2200WL $ kA THQD2225WL $ TJD 240 Vac, Internal Common Trip GO-15F # of Ampere 240 Vac Poles Rating Interrupting Rating Product Number 1,2 List Price kA TJD422250WL $ kA TJD42200WL $ kA TJD42250WL $ kA TJD422400WL $ kA TJD42250WL 4 $ kA TJD4200WL 4 $ kA TJD4250WL 4 $ kA TJD42400WL 4 $ Refer to table on page -101 for lug and wire range data. 2 Includes line and load lugs. For optional configurations see page -8. For additional shunt trip options see page TJD uses same accessories as J600 line. TJD not listed HACR. UL listed HACR (heating, air conditioning and refrigeration). TJD4200WL -22 BuyLog Catalog Rev. 12/04 distributed by AA Electric

23 Miniature Circuit Breakers and Supplementary Protectors Molded Case Switches Note: Molded case switches may be used as main devices in panelboards and switchboards but cannot be used as subfeeds or branch breakers because they do not provide wire protection. Q Line and TEB molded case switches have a 10,000 ampere symmetrical short circuit withstand rating when protected by a fuse or circuit breaker rated 10,000 amperes IC or greater and whose ampere rating does not exceed the ampere rating of the switch. Plug-in TQL 120/240, Vac Internal Common Trip GO-18 # of Ampere 120/240 Vac Poles Rating Short Circuit Withstand Rating Wire Range 1 Product Number List Price kA 8- Cu/8- Al TQL21Y60 $ kA 6-1/0 Cu/4-1/0 Al TQL21Y100 $ Plug-in TQL 240, Vac Internal Common Trip GO-18 # of Ampere 240 Vac Poles Rating Short Circuit Withstand Rating Wire Range 1 Product Number List Price kA 8- Cu/8- Al TQL22Y60 $ kA 6-1/0 Cu/4-1/0 Al TQL22Y100 $ kA 8- Cu/8- Al TQL2Y60 $ kA 6-1/0 Cu/4-1/0 Al TQL2Y100 $ Bolt-on TQB 120/240, Vac Internal Common Trip GO-18 # of Ampere 120/240 Vac Poles Rating Short Circuit Withstand Rating Wire Range 1 Product Number List Price kA 8- Cu/8- Al TQB21Y60 $ kA 6-1/0 Cu/4-1/0 Al TQB21Y100 $11.00 Bolt-on TQB 240 Vac, Internal Common Trip GO-18 # of Ampere 240 Vac Poles Rating Short Circuit Withstand Rating Wire Range 1 Product Number List Price kA 8- Cu/8- Al TQB22Y60 $ kA 6-1/0 Cu/4-1/0 Al TQB22Y100 $ kA 8- Cu/8- Al TQB2Y60 $ kA 6-1/0 Cu/4-1/0 Al TQB2Y100 $ Cable In-Cable Out (Lug-Lug) TQC 120/240 Vac, Internal Common Trip GO-15B # of Ampere 120/240 Vac Poles Rating Short Circuit Withstand Rating Wire Range 1 Product Number List Price kA 8- Cu/8- Al TQC21Y60 2 $ kA 6-1/0 Cu/4-1/0 Al TQC21Y100 $ Cable In-Cable Out (Lug-Lug) TQC 240 Vac, Internal Common Trip GO-15B # of Ampere 240 Vac Poles Rating Short Circuit Withstand Rating Wire Range 1 Product Number List Price kA 8- Cu/8- Al TQC22Y60 $ kA 6-1/0 Cu/4-1/0 Al TQC22Y100 $ kA 8- Cu/8- Al TQB2Y60 $ kA 6-1/0 Cu/4-1/0 Al TQB2Y100 $ Cable In-Cable Out (Lug-Lug) TQD, TJD 240 Vac, Internal Common Trip Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 GO-15F # of Ampere 240 Vac Poles Rating Short Circuit Withstand Rating Product Number 6 List Price kA TQD22Y225 $ kA TQD2Y225 4 $ kA TJD422Y400 $ kA TJD42Y400 5 $ Solid or stranded for AWG. 2 Suitable for mounting on 5 mm DIN rail. For additional shunt trip offerings, see page TQD2YT225 with dummy trip used for accessorized applications. 5 TJD uses same accessories as J600 line. 6 Refer to table on page -101 for lug and wire range data. Line and load lugs included in basic switch product number. BuyLog Catalog -2

24 E2000 Miniature Circuit Breakers EP60 Series Applications Residential Commercial Industrial Performance Thermal setting In (A) Rated Vac Un (V) 240/415 Minimum operating voltage U B min (V) 12 Tripping characteristics B-C-D Selectivity class Mechanical/electrical endurance 20000/10000 Tropicalisation acc. to IEC % RH at 55 C Terminal capacity flexible/rigid cable mm Poles 1, 2,, 4 Weight (g/pole) 120 Short-circuit Capacity Per UL 1077 & CSA 22.2 No (File E15119) Max. Voltage Short Circuit Rating Rating kaic RMS Symmetrical kaic DC Poles AC DC / Y/ Y/ , 4 480Y/ AC acc. to IEC Poles V Icn/Ics (ka) /400 6 AC acc. to IEC Poles V Icu (ka) ,, ,, Ics = 75% Icu DC acc. to IEC Poles V Icu/Ics (ka) Auxiliaries Add-on Devices Approval/Marking CE curus CEBEC KEMA EUR -24 BuyLog Catalog Rev. 12/04 distributed by AA Electric

25 E2000 Miniature Circuit Breakers EP60 Series EP60 Series, 6 or 480Y/277 Vac, Tripping Characteristics B-C-D GO-15VB Tripping Characteristic B (-5X) C (5-10X) D (10-20X) List Poles Std. Pack 6 kaic In (A) Product No. Product No. Product No. Price EP61ULC0.5 EP61ULD0.5 $ EP61ULC01 EP61ULD01 $ EP61ULC02 EP61ULD02 $65.00 EP61ULC0 EP61ULD0 $ EP61ULC04 EP61ULD04 $ EP61ULB05 EP61ULC05 EP61ULD05 $ EP61ULB06 EP61ULC06 EP61ULD06 $ EP61ULB10 EP61ULC10 EP61ULD10 $ EP61ULB1 EP61ULC1 EP61ULD1 $ EP61ULB15 EP61ULC15 EP61ULD15 $ EP61ULB16 EP61ULC16 EP61ULD16 $ EP61ULB20 EP61ULC20 EP61ULD20 $ EP61ULB25 EP61ULC25 EP61ULD25 $ EP61ULB0 EP61ULC0 EP61ULD0 $ EP61ULB2 EP61ULC2 EP61ULD2 $ EP61ULB40 EP61ULC40 EP61ULD40 $ EP61ULB50 EP61ULC50 EP61ULD50 $ EP61ULB60 EP61ULC60 EP61ULD60 $ EP61ULB6 EP61ULC6 EP61ULD6 $ EP62ULC0.5 EP62ULD0.5 $ EP62ULC01 EP62ULD01 $ EP62ULC02 EP62ULD02 $ EP62ULC0 EP62ULD0 $ EP62ULC04 EP62ULD04 $ EP62ULB05 EP62ULC05 EP62ULD05 $ EP62ULB06 EP62ULC06 EP62ULD06 $ EP62ULB10 EP62ULC10 EP62ULD10 $ EP62ULB1 EP62ULC1 EP62ULD1 $ EP62ULB15 EP62ULC15 EP62ULD15 $ EP62ULB16 EP62ULC16 EP62ULD16 $ EP62ULB20 EP62ULC20 EP62ULD20 $ EP62ULB25 EP62ULC25 EP62ULD25 $ EP62ULB0 EP62ULC0 EP62ULD0 $ EP62ULB2 EP62ULC2 EP62ULD2 $ EP62ULB40 EP62ULC40 EP62ULD40 $ EP62ULB50 EP62ULC50 EP62ULD50 $ EP62ULB60 EP62ULC60 EP62ULD60 $ EP62ULB6 EP62ULC6 EP62ULD6 $ EP6ULC0.5 EP6ULD0.5 $ EP6ULC01 EP6ULD01 $ EP6ULC02 EP6ULD02 $ EP6ULC0 EP6ULD0 $ EP6ULC04 EP6ULD04 $ EP6ULB05 EP6ULC05 EP6ULD05 $ EP6ULB06 EP6ULC06 EP6ULD06 $ EP6ULB10 EP6ULC10 EP6ULD10 $ EP6ULB1 EP6ULC1 EP6ULD1 $ EP6ULB15 EP6ULC15 EP6ULD15 $ EP6ULB16 EP6ULC16 EP6ULD16 $ EP6ULB20 EP6ULC20 EP6ULD20 $ EP6ULB25 EP6ULC25 EP6ULD25 $ EP6ULB0 EP6ULC0 EP6ULD0 $ EP6ULB2 EP6ULC2 EP6ULD2 $ EP6ULB40 EP6ULC40 EP6ULD40 $ EP6ULB50 EP6ULC50 EP6ULD50 $ EP6ULB60 EP6ULC60 EP6ULD60 $ EP6ULB6 EP6ULC6 EP6ULD6 $ EP64ULC0.5 EP64ULD0.5 $ EP64ULC01 EP64ULD01 $ EP64ULC02 EP64ULD02 $ EP64ULC0 EP64ULD0 $ EP64ULC04 EP64ULD04 $ EP64ULB05 EP64ULC05 EP64ULD05 $ EP64ULB06 EP64ULC06 EP64ULD06 $ EP64ULB10 EP64ULC10 EP64ULD10 $ EP64ULB1 EP64ULC1 EP64ULD1 $ EP64ULB15 EP64ULC15 EP64ULD15 $ EP64ULB16 EP64ULC16 EP64ULD16 $ EP64ULB20 EP64ULC20 EP64ULD20 $ EP64ULB25 EP64ULC25 EP64ULD25 $ EP64ULB0 EP64ULC0 EP64ULD0 $ EP64ULB2 EP64ULC2 EP64ULD2 $ EP64ULB40 EP64ULC40 EP64ULD40 $ EP64ULB50 EP64ULC50 EP64ULD50 $ EP64ULB60 EP64ULC60 EP64ULD60 $ EP64ULB6 EP64ULC6 EP64ULD6 $ Pole 2 Pole Pole 4 Pole Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -25

26 E2000 Miniature Circuit Breakers EP100 Series Applications Residential Commercial Industrial Performance Thermal setting In (A) Rated Vac Un (V) 240/415 Minimum operating voltage U B min (V) 12 Tripping characteristics B-C-D Selectivity class Mechanical/electrical endurance 20000/10000 Tropicalisation acc. to IEC % RH at 55 C Terminal capacity flexible/rigid cable mm Poles 1, 2,, 4 Weight (g/pole) 120 Short-circuit Capacity Per UL 1077 & CSA 22.2 No (File E15119) Max. Voltage Short Circuit Rating Rating kaic RMS Symmetrical kaic DC Poles AC DC / Y/ Y/ , 4 480Y/ AC acc. to IEC Poles V Icn (ka) / Ics = 75% Icu AC acc. to IEC Poles V Icu (ka) ,, ,, Ics = 50% Icu DC acc. to IEC Poles V Icu/Ics (ka) Auxiliaries Add-on Devices Approval/Marking CE curus CEBEC KEMA EUR -26 BuyLog Catalog Rev. 12/04 distributed by AA Electric

27 E2000 Miniature Circuit Breakers EP100 Series EP100 Series, 10 or 120/240 Vac, Tripping Characteristics B-C-D GO-15VB Tripping Characteristic B (-5X) C (5-10X) D (10-20X) List Poles Std. Pack 10 kaic In (A) Product No. Product No. Product No. Price EP101ULC0.5 EP101ULD0.5 $ EP101ULC01 EP101ULD01 $ EP101ULC02 EP101ULD02 $97.00 EP101ULC0 EP101ULD0 $ EP101ULC04 EP101ULD04 $ EP101ULB05 EP101ULC05 EP101ULD05 $ EP101ULB06 EP101ULC06 EP101ULD06 $ EP101ULB10 EP101ULC10 EP101ULD10 $ EP101ULB1 EP101ULC1 EP101ULD1 $ EP101ULB15 EP101ULC15 EP101ULD15 $ EP101ULB16 EP101ULC16 EP101ULD16 $ EP101ULB20 EP101ULC20 EP101ULD20 $ EP101ULB25 EP101ULC25 EP101ULD25 $ EP101ULB0 EP101ULC0 EP101ULD0 $ EP101ULB2 EP101ULC2 EP101ULD2 $ EP101ULB40 EP101ULC40 EP101ULD40 $ EP101ULB50 EP101ULC50 EP101ULD50 $ EP101ULB60 EP101ULC60 EP101ULD60 $ EP101ULB6 EP101ULC6 EP101ULD6 $ EP102ULC0.5 EP102ULD0.5 $ EP102ULC01 EP102ULD01 $ EP102ULC02 EP102ULD02 $ EP102ULC0 EP102ULD0 $ EP102ULC04 EP102ULD04 $ EP102ULB05 EP102ULC05 EP102ULD05 $ EP102ULB06 EP102ULC06 EP102ULD06 $ EP102ULB10 EP102ULC10 EP102ULD10 $ EP102ULB1 EP102ULC1 EP102ULD1 $ EP102ULB15 EP102ULC15 EP102ULD15 $ EP102ULB16 EP102ULC16 EP102ULD16 $ EP102ULB20 EP102ULC20 EP102ULD20 $ EP102ULB25 EP102ULC25 EP102ULD25 $ EP102ULB0 EP102ULC0 EP102ULD0 $ EP102ULB2 EP102ULC2 EP102ULD2 $ EP102ULB40 EP102ULC40 EP102ULD40 $ EP102ULB50 EP102ULC50 EP102ULD50 $ EP102ULB60 EP102ULC60 EP102ULD60 $ EP102ULB6 EP102ULC6 EP102ULD6 $ EP10ULC0.5 EP10ULD0.5 $ EP10ULC01 EP10ULD01 $ EP10ULC02 EP10ULD02 $04.00 EP10ULC0 EP10ULD0 $ EP10ULC04 EP10ULD04 $ EP10ULB05 EP10ULC05 EP10ULD05 $ EP10ULB06 EP10ULC06 EP10ULD06 $ EP10ULB10 EP10ULC10 EP10ULD10 $ EP10ULB1 EP10ULC1 EP10ULD1 $ EP10ULB15 EP10ULC15 EP10ULD15 $ EP10ULB16 EP10ULC16 EP10ULD16 $ EP10ULB20 EP10ULC20 EP10ULD20 $ EP10ULB25 EP10ULC25 EP10ULD25 $ EP10ULB0 EP10ULC0 EP10ULD0 $ EP10ULB2 EP10ULC2 EP10ULD2 $ EP10ULB40 EP10ULC40 EP10ULD40 $ EP10ULB50 EP10ULC50 EP10ULD50 $ EP10ULB60 EP10ULC60 EP10ULD60 $ EP10ULB6 EP10ULC6 EP10ULD6 $ EP104ULC0.5 EP104ULD0.5 $ EP104ULC01 EP104ULD01 $ EP104ULC02 EP104ULD02 $ EP104ULC0 EP104ULD0 $ EP104ULC04 EP104ULD04 $ EP104ULB05 EP104ULC05 EP104ULD05 $ EP104ULB06 EP104ULC06 EP104ULD06 $ EP104ULB10 EP104ULC10 EP104ULD10 $ EP104ULB1 EP104ULC1 EP104ULD1 $ EP104ULB15 EP104ULC15 EP104ULD15 $ EP104ULB16 EP104ULC16 EP104ULD16 $ EP104ULB20 EP104ULC20 EP104ULD20 $ EP104ULB25 EP104ULC25 EP104ULD25 $ EP104ULB0 EP104ULC0 EP104ULD0 $ EP104ULB2 EP104ULC2 EP104ULD2 $ EP104ULB40 EP104ULC40 EP104ULD40 $ EP104ULB50 EP104ULC50 EP104ULD50 $ EP104ULB60 EP104ULC60 EP104ULD60 $ EP104ULB6 EP104ULC6 EP104ULD6 $ Pole 2 Pole Pole 4 Pole Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -27

28 E2000 Miniature Circuit Breakers EP100 UC Series 1 Applications Industrial Performance Thermal setting In (A) Rated Vac Un (V) 240/400; 20/440 Minimum operating voltage U B min (V) 12 Tripping characteristics B-C Selectivity class Mechanical/electrical endurance 20000/10000 Tropicalisation acc. to IEC % RH at 55 C Terminal capacity flexible/rigid cable mm Poles 1, 2 Weight (g/pole) 120 Short-circuit Capacity AC acc. to IEC Poles V Icn/Ics (ka) 125 DC DC 6 20/400 AC DC DC AC 6 AC acc. to IEC Poles V Icu/Ics (ka) 1, AC 10 Approval/Marking IEC , DIN VDE 0641 CE 1 Not UL approved Auxiliaries Add-on Devices -28 BuyLog Catalog Rev. 12/04 distributed by AA Electric

29 E2000 Miniature Circuit Breakers EP100 UC Series 1 EP100 UC Series, 10 Vdc, 1 Pole, Tripping Characteristics B-C GO-15VB Tripping Characteristic B (-5X) C (5-10X) List Poles Std. Pack 6 kaic In (A) Product No. Product No. Price 0.5 EP101UCC0.5 $ EP101UCC01 $ EP101UCC02 $ EP101UCC04 $ EP101UCB06 EP101UCC06 $ EP101UCB10 EP101UCC10 $ EP101UCB16 EP101UCC16 $ EP101UCB20 EP101UCC20 $ EP101UCB25 EP101UCC25 $ EP101UCB2 EP101UCC2 $ EP101UCB40 EP101UCC40 $ EP101UCB50 EP101UCC50 $ EP101UCB6 EP101UCC6 $ EP102UCC0.5 $ EP102UCC01 $ EP102UCC02 $ EP102UCC04 $ EP102UCB06 EP102UCC06 $ EP102UCB10 EP102UCC10 $ EP102UCB16 EP102UCC16 $ EP102UCB20 EP102UCC20 $ EP102UCB25 EP102UCC25 $ EP102UCB2 EP102UCC2 $ EP102UCB40 EP102UCC40 $ EP102UCB50 EP102UCC50 $ EP102UCB6 EP102UCC6 $ Pole 1 Not UL approved 2 Pole Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -29

30 E2000 Miniature Circuit Breakers Series CA Auxiliary Switch and Bell Alarm Applications Commercial Industrial Features Common for all MCBs Can be coupled on both sides of MCBs Gold contact version available for low current and low voltage applications Stack up to four CA on left and right sides Permits the pass-through of busbars, pin and fork, top and bottom, by changing the position of the base of the auxiliaries Performance Change-over contacts 1 Form C Rate current In (A) 5 Rated voltage AC Un (V) 240 Electrical endurance Terminal capacity flexible/rigid cable (mm 2 ) 2.5 Weight (g) 70 Functions Auxiliary contacts are units to be added on to protection devices. They allow information about the status of the protection device to be monitored from a distance. Auxiliary contact CA H (function H) reports the OPEN/CLOSED status. CA S/H or CA S/H G act as either an auxiliary contact (function H) or a signal contact (function S). The user can set the function at the time of installation. When used as a signal contact, it reports information about the automatic tripping of the protection devices. A test button on the front simulates functions H or S. There are also a reset button for the contacts (function S) and a tripping signal (function S). Coupling Busbar pass-through Approval/Marking CE curus CEBEC KEMA EUR Stack-on Series CA GO-15VB Function Std. Pack Product No. List Price H 1 CA H $47.00 S/H 1 CA S/H $59.00 S/H (gold contacts) 1 CA S/H G $ /2 mod. H S -0 BuyLog Catalog Rev. 12/04 distributed by AA Electric

31 E2000 Miniature Circuit Breakers Series CB Auxiliary Switch and Bell Alarm Applications Commercial Industrial Features Common for all MCBs Can be coupled on both sides of MCBs There are two change-over contacts the upper one features changeable function S/H CB SH/HH-R couples to the right side of the protection devices; CB SH/HH-L couple to the left No stack-on possibilities (only one auxiliary) No busbar pass-through facilities Performance Change-over contacts 2 Form C Rate current In (A) 5 Rated voltage AC Un (V) 240 Electrical endurance Terminal capacity flexible/rigid cable (mm 2 ) 2.5 Weight (g) 80 Functions The bottom auxiliary contact (function H) reports the OPEN/CLOSED status. The top auxiliary contact can act as either an auxiliary contact (function H) or a signal contact (function S). The user can set the function at the time of installation. When used as a signal contact, it reports information about the automatic tripping of the protection devices. A test button on the front simulates functions H or S. There are also a reset button for the contacts (function S) and a tripping signal (function S). Coupling right Approval/Marking curus Coupling left Series CB GO-15VB Function Coupling Std. Pack Product No. List Price SH/HH Right 1 CB SH/HH-R $87.00 SH/HH Left 1 CB SH/HH-R $ /2 mod. H S Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -1

32 E2000 Miniature Circuit Breakers Shunt Trip and Undervoltage Release Applications Commercial Industrial Features Common devices for all miniature circuit breakers Can be coupled on both sides of MCBs Permits pass-through of busbars, pin and fork, at top or bottom terminals Stack up to four modules on left and right sides Approval/Marking curus IEC Shunt Trip Tele L The Tele L allows remote switching of any miniature circuit breaker by means of push buttons or any other automatic management processor. A built-in contact, in series with the coil, prevents burnout damage if the voltage remains. Shunt Trip Tele L Performance Rated voltage (V) 110/415, 110/125 DC (V) 24/60, 24/48 DC Tripping time (ms) <10 Electrical endurance Terminal capacity flexible/rigid cable (mm 2 ) 2.5 Weight (g) 125 Shunt Trip Tele L Voltage GO-15VB Poles Std. Pack AC DC Product No. List Price 1 1 Undervoltage Release Tele U V V TELE L-1 $ V V TELE L-2 $90.00 The Tele U releases the main miniature circuit breaker in case the power supply drops below 0.5xUn. Time delay is adjustable up to 00 ms. Undervoltage Release Tele U Performance Rated voltage AC UN (V) 240 Rated voltage DC/AC UN (V) 12, 24, 48 DC/AC Tripping voltage (V) 0.5xUN ±10% Resetting voltage (V) >0.5xUN ±10% Tripping time (ms) Adjustable 1-00 Electrical endurance 2000 Terminal capacity flexible/rigid cable (mm 2 ) 2.5 Weight (g) 125 Coupling Busbar pass-through Stack-on Undervoltage Release Tele U GO-15VB Poles Std. Pack Voltage Product No. List Price 1 1 AC 20V TELE U-20 $ AC/DC 12V TELE U-12 $ AC/DC 24V TELE U-24 $ AC/DC 48V TELE U-48 $ Shunt Trip Tele L Undervoltage Release Tele L -2 BuyLog Catalog Rev. 12/04 distributed by AA Electric

33 E2000 Miniature Circuit Breakers Technical Data Series EP60 EP100 EP100 UC Standards UL1077, EN UL1077, EN IEC EN Tripping characteristics B, C, D B, C, D B, C Nominal current A B: 6-6, C/D: B: 6-6, C/D: B: 6-6, C: Calibration temperature C Number of poles (# mod) 1/1+N/2//4 1/1+N/2//4 1/2 Neutral pole protected yes yes Nominal voltage Un AC 1P V 240/ / /415 2P V P/P+N/4P V DC 1P (1) Vdc P (in series) (1) Vdc Frequency Hz 50/60 50/60 50/60 Hz DC:magn.trip + 40% DC:magn.trip + 40% DC:magn.trip + 40% Hz DC:magn.trip + 50% 400:magn.trip + 50% 400:magn.trip + 50% Maximum service voltage Ubmax between two wires V 250/440; 5/ /440; 5/ /440; 250/440 Minimum service voltage Ubmin V 12; 12 12; 12 12; 12 Selectivity class (IEC 60898) Isolator application IEC yes yes yes Rated insulation voltage Pollution Degree 2 V Rated insulation voltage Pollution Degree V Impulse withstand test voltage Kv Insulation resistance Mohm Dielectric rigidity Kv Vibrations resistance (in x,y,z direction) (IEC 77/16,) g g g Endurance electrical at Un, In Endurance mechanical Utilization category (IEC ) A A A Mounting position any any any Incoming top or bottom yes yes yes Protection degree (outside/inside enclosure with door) IP20/IP40 IP20/IP40 IP20/IP40 Self extinguish degree (according to UL94) V2 V2 V2 Tropicalisation (according to IEC /DIN 40046) C/RH +55% C/95% RH +55% C/95% RH +55% C/95% RH Operating temperature C -25/+55-25/+55-25/+55 Storage temperature C -55/+55-55/+55-55/+55 Terminal capacity Rigid cable min/max (top) mm 2 1/5 1/5 1/5 Terminal capacity Flexible cable min*/max (top) mm / / /25 (*Flexible cable 0.75/1/1.5 mm 2 with cable lug) Terminal capacity Rigid cable min/max (bottom) mm 2 1/5 1/5 1/5 Terminal Capacity Flexible cable min*/max (bottom) mm / / /25 (*Flexible cable 0.75/1/1.5 mm 2 with cable lug) Torque Nm Add-on services Auxiliary contacts yes yes yes Add-on services Tele U yes yes yes Add-on services Tele L yes yes yes Busbar systems pin (top/bottom) (non-ul) yes/yes yes/yes yes/yes Busbar systems fork (top/bottom) (non-ul) -/yes -/yes -/yes Accessories yes yes yes Dimensions, weights, packaging (HxDxW) 86x68xW mm/mod Weight/mod g Package mod Approvals KEMA KEMA - CE-marking yes yes yes Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -

34 Miniature Circuit Breakers and Supplementary Protectors Accessories Terminals (Lugs) for Q Line Circuit Breakers GO-15B Ampere Rating Termination Type Wire Range (Cu/Al) Product Number List Price Lug (line only) 14-6/12-2 TQALA $ Lug (load only) 14-2/12-2 THQEL $ Quick connector (load only) (4) 14/(4) 12 THQECC $2.50 Internal Accessories for TEY (2- and -pole breaker only) Factory Installed Only GO-15B Auxiliary Switch, Single-Pole Add suffix to Breaker (6A at 240 Vac,1/2A at 125 Vdc, 1/4A at 250 Vdc) Product Number List Price Adder "A" switch (normally open) AS1A $ "B" switch (normally closed) AS1B $ "AB" switch (both) ASAB $ Shunt Trip Vac control voltage ST12 $58.00 Quick Connector THQECC Mounting Accessories for THQB, THQC, TEY GO-15B Product Ampere # of Used With List Type Rating Poles Frame Product Number Price Bolt-on Mounting Base TEY TEYB $1.50 THQB Back Mounting Plates 1 THQC TQCBMPA1 $8.0 Screw Type Back Mounting Plates 2 THQC TQCBMPA2 $9.80 Screw Type Back Mounting Plates THQC TQCBMPA $12.00 Screw Type Back Mounting Plates 10 THQC TQCBMPA10 $2.00 Screw Type Front-mounting Plates 1 THQC TQCFMP1 1 $8.0 Front-mounting Plates 2 THQC TQCFMP2 1 $9.80 Front-mounting Plates THQC TQCFMP 1 $12.00 Front-mounting Plates 4 THQC TQCFMP4 1 $14.00 Front/Rear Mounting 15-60A 1 & 2 THQC THQCFMK 2 $48.00 Clips DIN rail clips 15-60A 1 & 2 THQC THQCDIN 2 $ Not UL listed. Price is per pack. Load Lug THQEL Mounting Accessories for THQC, THQC-GF, GFEP, AF GO-1 Product Type # of Poles Used With Frame Product Number List Price Snap In Back 1 THQC, THQC-GF TQCGFBMPA1 $6.10 Mounting Plates Snap In Back 2 THQC, THQC-GF TQCGFBMPA2 $7.60 Mounting Plates Snap In Back THQC, THQC-GF TQCGFBMPA $9.10 Mounting Plates Snap In Back 10 THQC, THQC-GF TQCGFBMPA10 $25.00 Mounting Plates Mounting Kit THQCFMK Mounting Accessories for TQL G0-14A Product Ampere # of Used With List Type Rating Poles Frame Product Number Price Plug-in Mounting Base 70 amp 2 TQL 571B595DDG1 $2.75 Plug-in Mounting Base 70 amp TQL 571B595DDG2 $2.00 Plug-in Mounting Base 100 amp TQL 565B87G1 $8.00 Plug-in Mounting Base 100 amp 2 TQL 565B87G2 $ BuyLog Catalog Rev. 12/04 distributed by AA Electric

35 Miniature Circuit Breakers and Supplementary Protectors Accessories Handle Locking Devices GO-15B Product Type Used With Frame Product Number List Price Handle Locks - TQC THL10 $ Non Padlocking TQB TQL Handle Locks - THQP TQPL $ Non Padlocking Handle Locks - TEY TEYLD1 $5.00 Non Padlocking Handle Locks - E150 Line TLD $5.00 Non Padlocking Handle Locks - THLC2, 4 TFKLD1 $6.00 Non Padlocking F225 Line Handle Locks - SF250 SBD1 $ Non Padlocking SE150 THL10 Handle Locking Devices GO-17A Product Type Used With Frame Product Number List Price Handle Locks - Padlocking TQD TQDPLD1 $20.75 Handle Locks - Padlocking TQDL TQDLPDL1 $17.75 Handle Locks - Padlocking TQB THP100 $ TQL Handle Locks - Padlocking THQP TQPPL $5.75 Handle Locking Devices GO-15B Product Type Used With Frame Product Number List Price Handle Locks - Padlocking TQC TQPLD1 $4.70 Handle Locks - Padlocking TEY TEYPLD1 $9.00 Handle Locks - Padlocking E150 TEFPLD1 $8.00 TB1 Handle Locks - Padlocking THLC1 TLC1PLD1 $17.00 Handle Locks - Padlocking F225 TFKPLD1 $4.00 Handle Locks - Padlocking THLC2 TLC4PLD1 $22.00 THLC4 TLB4 Handle Locks - Padlocking J600 Line TJKPLD1 $8.00 Handle Locks - Padlocking K1200 Line TKMPLD1 $28.50 Handle Locking Devices GO-15S Product Type Used With Frame Product Number List Price Handle Locks - Padlocking SF250 SEPLD $8.70 SE150 Handle Locks - Padlocking SG600 SGPLD $15.00 Handle Locks - Padlocking SK1200 SKPLD $ GO-17A. GO-15S. Suitable for circuit breakers used in group mounted panelboard construction only except for J600, K1200, SE150/SE250, SG600 and SK1200 which screw down to face of breaker. THP100 Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -5

36 Miniature Circuit Breakers and Supplementary Protectors Accessories Handle Locking and Handle Extension Devices EUSERC Approved Factory Installed Only GO-15B Product Type Used With Frame Product Number List Price Handle Locks - Padlocking TQDPLD2 $2.00 Handle Locks - Padlocking TEDPLD2 $2.00 Handle Locks - Padlocking TJKPLD2 $48.00 Handle Locks - Padlocking THLC1PLD2 $48.00 Handle Locks - Padlocking THLC4PLD2 $48.00 Handle Locks - Padlocking SEFPLD2 $2.00 1,2 Handle Locks - Padlocking SGPLD2 $ Handle Locks - Padlocking SKPLD2 $ THT1 Handle Locking and Handle Extension Devices GO-17A Product Type Used With Frame Product Number List Price Snap-on Handle Tie - open THQP THT2 $2.0 Snap-on Handle Tie - solid TQL THT104 $2.0 Snap-on Handle Tie - solid, THQP THT1 $2.0 indicating Snap-on Handle Tie - trip TQC TQHT1 $2.0 indicating Handle Extension - replacement SK1200 SKHDLEXT $ Breaker Mounting Screw Kits GO-15B Product Type Used With Frame Product Number List Price Breaker Mounting Screw Kits THQB TQBS1 4 $ GO-15S. Field Installable For 2 THQPs separated by 2 side-by-side THQPs. 4 Price is per screw. Packaged in quantities of 24. Must be ordered in multiples of 24. THT104 TQHT1 THT2-6 BuyLog Catalog Rev. 12/04 distributed by AA Electric

37 Industrial Circuit Breakers Spectra RMS, Spectra RMS with MicroVersaTrip Plus Trip Units, Spectra RMS with MicroVersaTrip PM Trip Units, Thermal Magnetic and J/K with MicroVersaTrip RMS-9 and Power+ 4 Trip Units How to Order Spectra RMS Circuit Breakers Determine the required breaker frame, IC rating, and load requirements. Select frame, trip unit (rating plug), and lug, if required, product numbers from the tables on pages -48 to -58. For Spectra breakers with MicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Units refer to pages -59 through -61. Select field-mounted internal accessory product numbers, if required, on pages -8 and -84. Select fieldmounted external accessory product numbers, if required, on pages -92 through Order as separate items. Mag-Break Motor Circuit Protectors Determine the required frame and ampere requirements. Select frame, trip unit (rating plug), and lug, if required, product numbers from the table on pages -7 through -75. Select accessories as noted above for circuit breakers. The same accessories are used with both circuit breakers and motor circuit protectors. Order as separate items. Molded Case Switches Determine the required frame and ampere requirements. Select frame and lug, if required, product numbers from the table on page -72. Rating plugs are not used. Select accessories as noted above for circuit breakers. Internal accessories do not require dummy trips. The same accessories are used with both circuit breakers and molded case switches. Order as separate items. Unless otherwise noted, all circuit breakers are UL listed in File E Molded case switches are UL listed in File E Field-Installable Internal Accessories are UL listed in File E Distribution Cable Accessories for MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units are UL listed in File E E 150 Line Thermal Magnetic Circuit Breakers Magnetic Circuit Breakers Molded Case Switches The product numbers as shown in the following pages include the complete breaker or switch. All devices listed come with Cu/Al line and load lugs. If line lugs are not required on a breaker, eliminate WL from product number; for molded case switches see page -8. Unless otherwise noted, all circuit breakers are UL listed in File E Molded case switches are UL listed in File E F 225 Line Thermal Magnetic Circuit Breakers Magnetic Circuit Breakers Molded Case Switches These breakers are available with either noninterchangeable trips (designated Type TFJ) or interchangeable trips (designated Types TFK/THFK). When ordering Type TFJ, product number includes complete breaker, trip unit, CU/Al line and load lugs factory assembled. If line lugs are not required on a breaker, eliminate WL from product number, and subtract price of line lugs from price of complete breaker. If interchangeable trip (Types TFK/THFK) is required order one of two ways. Complete circuit breaker price includes frame, trip, Cu/Al line and load lugs. Units will be shipped unassembled unless specified on order must be factory assembled. If line lugs are not required on a breaker, eliminate WL from product number, and subtract price of line lugs from price of complete breaker. To order the frame, trip, and lugs separately, select the required components from table. Magnetic breakers must be ordered as components. A complete breaker consists of frame, trip unit, one line lug per pole and one load lug per pole. Price of Complete Circuit Breaker vs. ordering frame, trip, and line and load lugs separately is the same. Molded case switches can also be ordered as complete units (designated TFK---Y) or as separate components. They are UL listed only as complete units. To indicate required lugs, see page -8. Unless otherwise noted, all circuit breakers are UL listed in File E Molded case switches are UL listed in File E J 600 Line Thermal Magnetic Circuit Breakers Magnetic Circuit Breakers Molded Case Switches These breakers are available with either noninterchangeable trip (designated Type TJJ) or interchangeable trip (designated Type TJK and THJK). Type TJJ product numbers include frame, trip, Cu/Al line, and load lugs factory assembled. If line lugs are not required on the breaker, eliminate WL from product number, and subtract price of line lugs from price of complete breaker. TJK breakers are available in two frames, 400 ampere frame (125 to 400 amperes) and 600 ampere frame (250 to 600 amperes). Trip units are not interchangeable between frames. Complete Circuit Breaker price includes frame, trip unit, Cu/Al line, and load lugs. Unit will be shipped unassembled unless order specifies must be factory assembled. If line lugs are not required, eliminate WL from product number and subtract price of line lugs from price of complete breaker. To order the frame, trip, and lugs separately, select the required components from table. Magnetic breakers must be ordered as components. A complete breaker consists of frame, trip, and one line and one load lug per pole. Price of ordering Complete Circuit Breaker vs. frame, trip, and line and load lugs separately is the same. Molded case switches can also be ordered as complete units (designated Type TJK---Y) or as separate components. They are UL listed only as complete units. To indicate required lugs, see page -8. Unless otherwise noted, all circuit breakers are UL listed in File E Molded case switches are UL listed in File E Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -7

38 Industrial Case Circuit Breakers K 1200 Line Thermal Magnetic Circuit Breakers Magnetic Breakers Molded Case Switches These breakers are available only with interchangeable trip units. Two frame sizes are available, the 800 ampere frame (00 to 800 amperes) and the 1200 ampere frame (600 to 1200 amperes). Trip units are not interchangeable between frames. Complete Circuit Breaker price includes frame, trip, Cu/Al line, and load lugs. Units will be shipped unassembled unless specified must be factory assembled. If line lugs are not required on the breaker, eliminate WL from product number and subtract price of line lugs. To order the frame, trip, and lugs separately, select the required components from table. Magnetic circuit breakers must be ordered as components. A complete breaker consists of frame, trip and one line and one load lug per pole. Price of ordering Complete Circuit Breaker vs. frame, trip, and line and load lugs separately is the same. Molded case switches can also be ordered as complete units (designated Type TKMA---Y) or as separate components. They are UL listed only as complete units. To indicate required lugs, see the table below. Unless otherwise noted, all circuit breakers are UL listed in File E Molded case switches are UL listed in File E R Frame 1000/1600/2000 Ampere Molded Case Circuit Breakers Solid-state MicroVersaTrip Plus or MicroVersaTrip PM Trip Unit Interchangeable trip unit via rating plugs 65 and 100 ka ratings available Standard and 100% rated versions Uses standard Power Break accessories Stationary/manual only Circuit Breakers with MicroVersaTrip Trip Units Solid-state construction with MicroVersaTrip Plus digital rms sensing microprocessor trip units. Available in J and K frame construction with ampere ratings from A. For ordering information see pages -80 through -82. UL listed, File E All breakers are UL listed in File E Tri-Break Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case Switches These breakers are available in four types. Type TB1 ( amperes) product numbers include frame, trip, line and load lugs, and current limiters all factory assembled. Types TB4 (125 to 400 amperes), TB6 (00 to 600 amperes) and TB8 (600 to 800 amperes) include frame, trip and limiters, factory assembled, but do not include line or load lugs. If line and load lugs are required, order separately. Unless otherwise noted, TB1, TB4, TB6, and TB8 breaker components are UL listed in File E Fused molded case switches are UL listed in File E Mag-Break Line Magnetic only circuit breakers (motor circuit protectors) These breakers are available only with noninterchangeable adjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break. All breakers are shipped factory assembled, complete with Cu/Al line and load lugs. All magnetic only circuit breakers and limiters are UL Component Recognized in Files E and E 6690, respectively, unless otherwise noted. Accessories Order accessories from the appropriate table: Thermal Magnetic Circuit Breakers, Magnetic Circuit Breakers, and Molded Case Switches 1 pages -85 to MicroVersaTrip Plus or Power+ 4-function J and K frame Solid State Circuit Breakers pages -85 to Spectra RMS Breakers pages -8 to -84 and -92 to Spectra RMS Breakers with MicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Units pages -8 to -84, -92 to -104 and -106 to Installation of accessories in molded case switches requires dummy trip; see page -91 for information. Dummy trip not required for Tri-Break or Q Line molded case switches. Molded Case Circuit Breaker and Switch Terminal Configuration Code Order standard Cu/Al lugs by using suffix codes presented. Order lugs separately if special lugs are required. For optional lugs, see pages -101 and Breaker/Switch Typ e TQD/TJD Molded Case Breakers, Thermal Magnetic Molded Case Switch Spectra RMS Breakers J.K. MicroVersaTrip Breakers Mine Duty Breakers Mag-Break Breakers TEB, TED, THED Blank WL XL X2 LL Load Lugs Only Load Lugs Only Line and Load Lugs Line and Load Lugs Line and Load Lugs No Lugs No Lugs No Lugs No Lugs Suffix Line Lugs Only Load Lugs Only Line Lugs Only No Lugs No Lugs Load Lugs Only Order Lugs Separately Order Lugs Separately Order Lugs Separately Line and Load Lugs -8 BuyLog Catalog Rev. 12/04 distributed by AA Electric

39 Industrial Circuit Breakers How To Order Spectra RMS Circuit Breakers with MicroVersa Trip Plus Trip Units How to Order Determine the required breaker frame (i.e., 150, 400, 600, 800, or 1200 amperes), IC rating, and load requirements (UL Standard or 100%). Determine overcurrent protective functions (LI, LSI, LIG, LSIG). Select frame product number and list price from table on pages -59 to -61 and -66 to -68. Select and price the required rating plug from table below. The sensor rating of frame must match the sensor rating of the rating plug in table. Select and price lugs and lug covers as required from page -102 and -10. Select and price appropriate combination of Power Management System accessories from pages -106 to Select and price any other accessories from pages -8 to -84 and -92 to When ordering, specify separate product numbers as follows: Frame Rating Plug Lugs Power Management Accessories Other Accessories Note: All Spectra RMS breakers with ground fault option will have a breaker cable. If the breaker is connected to a Ø4w or 1Øw service, a terminal block or junction box is required for connection to the neutral current sensor. Trip Function Definitions Long-Time (L) Short-Time (S) Instantaneous (I) Ground Fault (G) Control Power (CP) Adjustable current setting Adjustable long-time delay Adjustable short-time pick-up Adjustable short-time delay with I2t Adjustable short-time delay without I2t Adjustable pick-up Adjustable ground fault pick-up adjustable ground fault delay with I2t Adjustable ground fault delay without I2t +24 Vdc control power connection Pricing Example SG600 frame, 400 ampere sensor, 400 ampere rating plug, 100kAIC, 100% rated. Trip functions to include long-time (L), short-time (S), instantaneous (I) and ground fault. -phase/4 wire system with 400 ampere neutral sensor. Load lugs only. 120 Vac shunt trip and two stage auxiliary switch (2AB) with signal level contacts. Description Product Number List Price GO-15S Frame SGPP6BD0400 $ Rating Plug SRPG400B400 $ Load Lugs ( pole kit) TCLK65 $42.00 Terminal Block SDCTBA11 $ A neutral sensor TSRG204 $ Vac Shunt Trip SAST1 $6.00 2AB Aux. Switch SAUXGAB2 $ GO-15PM. MicroVersaTrip Plus and PM Rating Plug Selection All Plugs List Price, $ GO-15S Circuit Breaker Sensor Rating Plug Rating Plug Frame Rating Rating (Amperes) Product No. 60 SRPG150B60 80 SRPG150B SRPG150B SRPG150B SRPG150B SRPG400B SRPG400B200 SGHB, SGHH, SGLB, 225 SRPG400B225 SGLL, SGPB, SGPP SRPG400B SRPG400B00 50 SRPG400B SRPG400B SRPG600B SRPG600B SRPG600B SRPG600B SRPG600B SRPK800B SRPK800B SRPK800B SRPK800B600 SKHB, SKHH, SKLB, 700 SRPK800B700 SKLL, SKPB, SKPP 800 SRPK800B SRPK1200B SRPK1200B SRPK1200B SRPK1200B SRPK1200B Not suitable for use with 100% rated, 1000A breaker frame. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -9

40 Industrial Circuit Breakers Spectra RMS Circuit Breakers with MicroVersaTrip PM Trip Units MicroVersaTrip PM Trip Unit The MicroVersaTrip PM trip unit adds power management system capability, advanced metering, and protective relays to the basic functions of MicroVersaTrip Plus. MicroVersaTrip PM trip units communicate directly on the GE POWER LEADER communications bus. Suitable for use in applications from 45 Hz to 66 Hz. Not suitable for 400 Hz. Standard Features Adjustable Long-Time (L) pickup, X, and delay (-4 bands). Adjustable Instantaneous (I) pickup, X. Local Overload and Short-Circuit Trip Indicators (T) with overload pickup warning. Interchangeable trip rating plugs with test set jack for TVRMS test set. Digital LCD display with four-button keypad for function selection and set point adjustment and sealable, clear Lexan cover for tamper-resistant settings. True rms sensing for accurate response to high harmonic content waveforms. EMI immunity per ANSI C7.90. POWER LEADER Communications System Link with userselectable address assignment for COMNET communication. Metering -Phase Ammeter with ±4% accuracy. -Phase Voltmeter, 1X, configurable for Wye and Delta systems. Frequency Meter, ±1 Hz kw Meter, ±7% (real power) kva Meter, ±6% (apparent power) kwh Meter, ±6% (energy) Control Power 24 Vdc provides connection capability for +24 Vdc control power into the breaker via the distribution cable system. Note: MicroVersaTrip PM functions require 24 Vdc control power and voltage sensing signals. Universal Internal Accessories Uses the same front-mounted, field-installable shunt trips, undervoltage releases, bell alarms, and auxiliary switches as standard Spectra RMS breakers. Accessory Lead Routing Left or Right Side channels mean no extra space required for accessory leads. Current Limiting SG600 frames rated 65kA and 480 Vac are UL listed as current limiting. Reverse Feed Front-mounted interchangeable rating plugs mean all frames are UL listed for reverse feed. Wide Current Setting Range Interchangeable rating plugs combined with 5 current sensors and X long time pickup yield ampere ratings from 0 to 1200A. 100% Continuous Current Rated Optionally available for 100% UL continuous current rating applications. Optional Features Adjustable Short-Time (S) pickup, C, and delay (4 bands) with I 2 t IN/OUT selection. Adjustable Ground fault (G) pickup, S, and delay (4 bands) with I 2 t IN/OUT selection and trip indicator. The 4 short-time and ground fault delay bands provide broader system selectivity. Protective Relays User selectable in any combination from 1 to 5 relays Current Unbalance Relay Undervoltage Relay Overvoltage Relay Voltage Unbalance Relay Power Reversal Relay -40 BuyLog Catalog Rev. 12/04 distributed by AA Electric

41 Industrial Circuit Breakers Spectra RMS Circuit Breakers with MicroVersaTrip PM Trip Units MicroVersaTrip PM Trip Unit Characteristics Current Setting (C) Pickup (Multiple of Rating Plus Amperes) (X) 0.50 to 1.0 in increments of 0.05 (11 Settings) Long-Time1 Delay (Seconds) 2.4,4.9,9,8,20 2, (-4 Bands) Pick-Up (Multiple of Current Settings) (C) 1.5 to 9.0 in increments of 0.5 (16 Settings) Short-Time Delay (Seconds) I 2 t IN 0.44 I 2 T OUT 4 0.1, 0.2, 0., 0.4 (8 Bands) Adjustable Instantaneous Pickup (Multiple of Rating Plug Amperes) (X) 1.5 to 10.0 in increments of 0.5 (18 Settings) Pick-Up (Multiple of Sensor Ampere Rating) (S) 0.2 to 1.0 in increments of 0.05 (17 Settings) X = Rating Plug Amperes S = Sensor Ampere Rating C = Long-Time Current Settings (Pickup) C = X Times Long-Time Pickup Setting 1 Pick-up fixed at 1.1C second delay (band) not available on SG frames. Time delay at 600% of current setting at lower limit of each band. 4Time delay shown at lower limit of each band. Pickup tolerances ± 10%. Ground Fault Pick-up not to exceed 1200 amperes. 5 Time delay at 200% of pickup setting at the lower limit of each band. Ground Fault Delay (Seconds) I 2 t IN I 2 t OUT 4 0.1, 0.2, 0., 0.4 (8 Bands) PM Trip Unit Functions Accuracy and Description Metering (M) Metering and Relaying (PM) Amperes (A) Current ±4% Selectable Phase Voltage (V) Volts ±2% Selectable Phase in L-L or L-N Energy (kwh/mwh) Watt hours ±7% Total energy flow through breaker Real Power (kw/mw) Watts ±6% L-L or L-N Power Apparent Power (kva/mva) Volt amps ±6% L-L or L-N Power Frequency (45-66 Hz) Hertz ±6% Voltage Unbalance Relay Adjustable pickup, 10 to 50% Adjustable delay, 1 to 15 seconds or OFF Current Unbalance Relay Adjustable pickup, 10 to 50% Adjustable delay, 1 to 15 seconds or OFF Undervoltage Relay Overvoltage Relay Power Reversal Relay Communications Adjustable pickup, 50 to 90% Adjustable delay, 1 to 15 seconds or OFF Adjustable pickup, 110 to 150% Adjustable delay, 1 to 15 seconds or OFF Adjustable pickup, 0.01 MW to.90 MW Adjustable delay, 1 to 15 seconds or OFF POWER LEADER Communications System Link (comment) Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -41

42 Industrial Circuit Breakers Spectra RMS Circuit Breakers with MicroVersaTrip PM Trip Units How to Order Determine the required breaker frame (i.e., 150, 400, 600, 800, or 1200 amperes), IC rating, and load requirements (UL Standard or 100%). Determine overcurrent protective functions (LI, LSI, LIG, LSIG) and whether protective relaying is required. Select frame product number and list price from table on pages -59 to -61 and -66 and -68. Select and price the required rating plug from table below. The sensor rating of frame must match the sensor rating of the rating plug in table. Select and price lugs and lug covers as required from page -102 and -10. Select and price appropriate combination of Power Management System accessories from pages -106 to Select and price an auxiliary switch as required from page Select and price any other accessories from pages -8 to -84 and -92 to When ordering, specify separate product numbers as follows: Frame Rating Plug Lugs Auxiliary Switch Power Management System Accessories Other Accessories Trip Unit Function Definitions Long-Time (L) Short-Time (S) Instantaneous (I) Ground Fault (G) Trip Indication Targets Full Metering (Standard) Protective Relay Functions Adjustable current setting Adjustable long-time delay Adjustable short-time pick-up Adjustable short-time delay with l 2 t Adjustable short-time delay without l 2 t Adjustable pick-up Adjustable ground fault pick-up Adjustable ground fault delay with l 2 t Adjustable ground fault delay without l 2 t Standard Amperes (A/kA) Phase Selectable Voltage (V) L-L or L-N and Phase Selectable Energy (kwh/mwh) Real Power (kw) L-L or L-N Total Power (kva) L-L or L-N Frequency (45-66 Hz) Adjustable Undervoltage pick-up Adjustable Undervoltage delay or OFF Adjustable Overvoltage pick-up Adjustable Overvoltage delay or OFF Adjustable Voltage Unbalance pick-up Adjustable Voltage Unbalance delay or OFF Adjustable Current Unbalance pick-up Adjustable Current Unbalance delay or OFF Adjustable Power Reversal pick-up Adjustable Power Reversal delay or OFF Pricing Example SG600 ampere frame breaker, 100% UL rated with 400 ampere sensors and 400 ampere rating plug with line and load lugs. Trip functions to include adjustable long-time (L), short-time (S), instantaneous (I) and equipment ground fault (G) and internal protective relay functions of current unbalance (CU), voltage unbalance (VU), undervoltage (UV), overvoltage (OV) and power reversal (PR). Local metering values available at the breaker shall include Current (Amperes), Voltage (Volts), Energy (kwh), Real Power (kw), Apparent Power (kva) and Frequency (Hz). The available system is 277/480 Vac, -phase/4-wire with 100 kaic fault current available. The Distribution Cable Accessories are to be mounted on plates with all the necessary fuse protection, potential transformers, control power transformers, etc. Description Product Number List Price GO Schedule Frame SGPP6DD0400 $ PM Rating Plug SRPG400B400 $ S Line and Load Lugs (2- Pole Kits) TCLK65 $ S Auxiliary Switch SAUXPAB1 $ S Power Supply Plate SPSA480 $ PM Voltage Conditioner Plate SVCA480Y $ PM Junction Box SDCJBA $ PM Harness (2) SPCHA11 $ PM 400A Neutral Current Sensor TSRG204 $ S MicroVersaTrip Plus and PM Rating Plug Selection All Plugs List Price, $ GO-15S Circuit Breaker Sensor Rating Plug Rating Plug Frame Rating Rating (Amperes) Product No. 60 SRPG150B60 80 SRPG150B SRPG150B SRPG150B SRPG150B SRPG400B SRPG400B200 SGHB, SGHH, SGLB, 225 SRPG400B225 SGLL, SGPB, SGPP SRPG400B SRPG400B00 50 SRPG400B SRPG400B SRPG600B SRPG600B SRPG600B SRPG600B SRPG600B SRPK800B SRPK800B SRPK800B SRPK800B600 SKHB, SKHH, SKLB, 700 SRPK800B700 SKLL, SKPB, SKPP 800 SRPK800B SRPK1200B SRPK1200B SRPK1200B SRPK1200B SRPK1200B Not suitable for use with 100% rated, 1000A breaker frame. -42 BuyLog Catalog Rev. 12/04 distributed by AA Electric

43 Industrial Circuit Breakers R-Frame Molded Case Circuit Breakers Solid-State Interchangeable Trip A, 600 Vac, 65,100 Standard and 100% Rated MicroVersaTripPlus Suitable for Reverse Feed How To Order: 1. Select frame product number. 2. Select rating plug for current rating from page Select appropriate accessories and lugs from page Include suffix s for factory installation. Example Description Frame Rating Plug Neutral CT Shunt Trip Auxiliary Switch Padlocking Provision Line Side Terminations (Optional) Load Side Terminations Adapter Kit Lugs (2 per pole) Product Number TRPP6BD10 TR10B600 TSVG810A TPST12 TPAS2AB4 Standard ()TP16FCA (1)TPLUGA16 (6)TPLUG108 R-Frame UL Listed Interrupting Ratings - rms Symmetrical Amperes Continuous Current Rating Frame Type 80% 100% Standard Break LA LL Hi-Break PA PP Interrupting Rating (rms sym.) 240 Vac 100,000 Amperes 480 Vac 65,000 Amperes 600 Vac 50,000 Amperes 240 Vac 125,000 Amperes 480 Vac 100,000 Amperes 600 Vac 65,000 Amperes MicroVersaTrip Plus Trip Unit Selection Trip Unit Function Definitions Long-Time (L) Short-Time (S) Instantaneous (I) Ground Fault (G) Trip Indication Target (T1, T2) Zone Selective Interlock (Z1, Z2) Trip Unit Functions Available R-Frame Breaker Function Code Adjustable current setting Adjustable long-time delay Adjustable short-time pick-up Adjustable short-time delay with I 2 t Adjustable short-time delay without I 2 t Adjustable pick-up Adjustable ground fault pick-up Adjustable ground fault delay with I 2 t Adjustable ground fault delay without I 2 t Overload/short circuit targets (T1) Overload/short circuit/ground fault targets (T2) Ground fault (Z1) Ground fault/short-time (Z2) Targets (T) Zone Interlock GF (Z1) 2 Zone Interlock GF, ST (Z2) Long Short Instantaneous Ground OL, Time (L) Time (S) (I) Fault (G)1 OL, SC SC, GF A B C D E F G 1 For single-phase, -wire or -phase, 4-wire GF applications select neutral-current sensor on page Zone interlocking requires purchase of interlock module TIM1 (120 Vac control voltage). Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -4

44 Industrial Circuit Breakers A Circuit Breakers Electric Trip Spectra RMS Breakers Quick Reference Guide Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage. Spectra RMS Circuit Breakers UL/CSA Ratings Solid-State with Interchangeable Trip Unit (Rating Plug) Circuit UL Listed Interrupting Rating ka Dimensions Inches (mm) Approx. Ship Breaker Ampere No. Maximum Wt./Std. Type Rating Poles Vac 240 Vac 480 Vac 600 Vac H W D A B C E Pack SE150 Current Limiting (UL File No. E-11592; CSA LR 4050) SED SEH SEL SEP SF-250 Current Limiting (UL File No. E-11592; CSA LR 4050) SFH SFL SFP SG600 Current Limiting (UL File No. E-11592; CSA LR 4050) SGH1 2, SGD SGH SGH SGL SGP (256) (140) (97) (11) (84) (2) (0) SGL SGP SGL SGP SK1200 (UL File No. E-11592; CSA LR 4050) 2 SKH SKL SKP (94) 8.25 (210) 5.50 (140) 8.56 (217) 5.69 (145) 1.8 (5).62 (16) 47.6 lb/ 1 SKH SKL SKP UL listed as HACR (heating, air conditioning and refrigeration) type. 4 MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units only. 2 Not current-limiting circuit breaker. 5 Add 1.76 inches (45 mm) to each end with lugs and lug cover installed. Includes MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units. 6 Add 4.00 inches (101 mm) to upper end for SKP (100 kaic-480v) lug cover. 6.1 (160) (257) 4.12 (105) 4.12 (105).8 (86).81 (97) 2.41 (61).87 (98) 2.47 (6).87 (98).69 (18).69 (18).72 (18) 1.19 (0) 5.65 lb/ lb/ lb/ 1-44 BuyLog Catalog Rev. 12/04 distributed by AA Electric

45 Industrial Circuit Breakers A Circuit Breakers Electric Trip Spectra RMS Breakers Quick Reference Guide Ratings do not apply to molded case switches IEC/JIS Ratings Solid-State with Interchangeable Trip Unit (Rating Plug) Circuit Breaker Type Ampere Rating No. Poles SE150 Current Limiting, 15-2A IEC Interruption Capacity ka Vac Vac 500 Vac 690 Vac Japanese Industry Standard Interruption Capacity ka Vac I cu I cs I cu I cs I cu I cs I cu I cs SED SEH SEL SEP SE150 Current Limiting, A SED SEH SEL SEP SF250 Current Limiting SFH SFL SFP SG600 Current Limiting SGH SGH SGH SGL SGP SGL SGP SGL SGP SK1200 SKH SKL SKP SKH12 SKL12 SKP MicroVersaTrip Plus trip system only SE SF SG SK Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -45

46 Industrial Circuit Breakers A Circuit Breakers Thermal Magnetic Trip Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage. TJJ, TJK, THJK TFJ, TFK, THFK Quick Reference Guide E150 (UL File E-11592; Fixed Thermal Magnetic Trip Unit; CSA LR 57114) Circuit Breaker Type Ampere Rating No. Poles Maximum Voltage Rating ac dc 120 UL Listed Interrupting Ratings ka Vac 120/ H W D A B C E TEB /8 26 lb/ /16 2 /4 /8 2 41/ /64 2/2 24 lb/ /8 11/16 28 lb/ , /8 26 lb/24 TED /16 2 /4 /8 2 41/ /64 2/2 24 lb/ /8 11/16 28 lb/ , /8 26 lb/24 THED /16 /8 24 lb/ , /8 2 41/ /64 2/2 11/16 28 lb/ TEL /16 4 1/8 29/2 2 7/ /2 11/16 2/2 1/2 lb/1 Vdc Dimensions (In.) Approx. Ship Wt./Std. Pack F225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 4050) Circuit Breaker Type Ampere Rating No. Poles UL Listed Interrupting Ratings ka Maximum Voltage Rating Vac Vdc Dimensions (In.) Approx. Ship ac dc / H W D A B C E Wt./Std. Pack lb/1 TFJ /8 4 1/8 1/16 7/8 7/8 11/16 1 / lb/ lb/1 TFK /8 4 1/8 1/16 7/8 7/8 11/16 1 /16 12 lb/1 THFK lb/ /8 4 1/8 1/16 7/8 7/8 11/16 1 / lb/1 TFL /8 4 1/8 1/16 7/8 7/8 11/16 1 /16 J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 4050) TJJ, 16 lb/ /8 8 1/4 1/16 15/16 1/16 1 /8 1 /16 TJK4 17 1/2 lb/ lb/1 TJK /8 8 1/4 1/16 15/16 1/16 1 /8 1 / lb/ lb/1 THJK /8 8 1/4 1/16 15/16 1/16 1 /8 1 / /2 lb/ lb/1 THJK /8 8 1/4 1/16 15/16 1/16 1 /8 1 /16 20 lb/1 K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 4050) TKM /2 8 1/4 5 1/2 8 9/ /16 1 /8 5/8 lb/ lb/1 TKM /2 8 1/4 5 1/2 8 9/ /16 1 /8 5/8 8 lb/1 41 1/2 lb/1 THKM lb/ /2 8 1/4 5 1/2 8 9/ /16 1 /8 5/8 9 lb/1 THKM /2 8 1/4 5 1/2 8 9/ /16 1 /8 5/8 8 lb/1 41 1/2 lb/1 1 UL listed with poles in series for 500 Vdc ungrounded battery applications. 5 UL listed at 10,000 amps. All UL listed as HACR type. 6 Discontinued 10 amp not UL listed. 7 Also 10,000 amps at 500 Volts dc. Not UL listed. 4 UL listed/csa Certified for 47 Vac (TED) and 47V Vdc on TJK only. (THED). Also rated 480V but not UL listed. -46 BuyLog Catalog Rev. 12/04 distributed by AA Electric

47 Molded Case Circuit Breakers Quick Reference Guide Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage. TJC TJL6S R Frame 1 (UL File E-11592; Interchangeable Solid-State MicroVersaTrip Plus Trip Unit; CSA LR 1026) Circuit Breaker Type ac dc / H W D A B C E TRL 10, /2 1 1/2 8 5/16 90/1 TRP 10, /2 1 1/2 8 5/16 90/1 TRL /2 8 5/16 96/1 TRP /2 8 5/16 96/1 Tri-Break (UL File E-4226; Integrally Fused, Thermal Magnetic Trip Unit) TB1 2, TB4 2, / /8 4 1/8 8 1/4 5/8 4 1/2 2 21/2 15/16 6 9/2 9 1/16 11/16 1 /8 2/2 1 /16 8 lb/1 1 lb/1 TB6 2, /8 8 1/4 5 7/8 8 9/ /16 1 /8 5/8 lb/1 5 lb/1 TB8 2, /8 8 1/4 5 7/8 8 9/ /16 1 /8 5/8 55 lb/1 5 lb/1 55 lb/1 Mag-Break (UL Files E-11592, E-6690; Magnetic Trip Unit) 5 TEC /16 4 1/8 /8 2 41/ /64 11/16 2/2 21 lb/6 600 TEML /16 4 1/8 7/8 2 41/ /64 11/16 2/2 1/2 lb/1 TEC & TECL /16 4 1/8 /8 2 41/ /64 11/16 2/2 TFC TBC4 TJC TBC /8 8 1/4 5 7/8 8 9/ /16 1 /8 5/8 TKC MicroVersaTrip (UL File E-11592; Solid-State Trip Units) TJ4V 8, THJ4V 8, /8 8 1/4 1/16 15/16 1/16 1 /8 1 /16 TJL4V TK4V /2 8 1/4 5 1/2 8 9/ /16 1 /8 5/8 TKL4V /2 8 1/4 5 1/2 8 9/ /16 1 /8 5/8 TJH1S-6S /8 8 1/4 1/16 15/16 9 1/16 1 /8 1 /16 TJL1S-6S /8 8 1/4 1/16 15/16 9 1/16 1 /8 1 /16 TKH8S, 12S /8 8 1/4 5 1/2 8 9/ /16 1 /8 5/8 TKL8S, 12S /8 8 1/4 5 1/2 8 9/ /16 1 /8 5/8 4 CSA LR Ampere Rating /8 4 1/8 1/16 7/8 7/8 11/16 1 / No. Poles Maximum Voltage Rating 600 TBC UL Listed Interrupting Ratings rms Symmetrical Amps (In Thousands) Vac /8 8 1/4 1/16 1/16 1/16 1 / /8 15 1/2 8 1/4 21 7/8 8 1/4 Dimensions (In.) 4 1/2 15/16 9 1/16 1 /8 8 1/4 5 1/2 8 9/ /16 1 /8 5/8 5 7/8 8 9/ /16 1 /8 1 Rotary handle (not toggle handle). 5 Per UL 489, interrupting capacities are not shown on product label. 2 UL listed with internally mounted accessories at 100,000 amps IC. 6 Discontinued. Contact GE Sales Office for availability of 200 kaic ratings with 7 Ratings shown for TEC in combination with TECL. internal accessories. 8 With Power+ 4 trip unit. CSA LR Suitable for single-phase, use outer two poles. Vdc 1 /16 1 /16 5/8 Approx. Ship Wt./Std. Pack 1.2 lb/1 TECL Only 10 lb/1 12 lb/1 1 lb/1 lb/1 16 lb/1 17 1/2/1 5 lb/1 55 lb/1 8 lb/1 41 1/2/1 5 lb/1 55 lb/1 Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -47

48 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SE150 Line Circuit Breakers Features Interchangeable trip using rating plugs True digital rms sensing Universal internal accessories UL listed for field installation Adjustable instantaneous with short-time tracking function CE marked SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050, UL listed HACR SEL, SEP UL Current Limiting 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Adj. Inst. Trip Range Amps UL 489 Vac UL 489 Vac 18kA 25kA Ampere Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Number Price Number Price Number Price Range SRPE0A15 $ SRPE0A20 $ SRPE0A25 $ SEDA24AT000 $ SEHA24AT000 $ SRPE0A0 $ SRPE60A40 $ SRPE60A50 $ SEDA24AT0060 $ SEHA24AT0060 $ SRPE60A60 $ SRPE100A70 $ SRPE100A80 $ SRPE100A90 $ SEDA24AT0100 $12.00 SEHA24AT0100 $ SRPE100A100 $ SRPE150A110 $ SRPE150A125 $ SEDA24AT0150 $87.00 SEHA24AT0150 $ SRPE150A150 $ SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050, UL listed HACR 2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max. 12-/0 Cu TCAL18 $ /0 Al GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Adj. Inst. Trip Range Amps UL 489 Vac UL 489 Vac 65kA 100kA Ampere Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Number Price Number Price Number Price Range SRPE0A15 $ SRPE0A20 $ SRPE0A25 $ SELA24AT000 $ SEPA24AT000 $ SRPE0A0 $ SRPE60A40 $ SRPE60A50 $ SELA24AT0060 $ SEPA24AT0060 $ SRPE60A60 $ TCAL18 $ /0 Cu SRPE100A70 $ /0 Al SRPE100A80 $ SRPE100A90 $ SELA24AT0100 $ SEPA24AT0100 $ SRPE100A100 $ SRPE150A110 $ SRPE150A125 $ SELA24AT0150 $ SEPA24AT0150 $ SRPE150A150 $ BuyLog Catalog Rev. 12/04 distributed by AA Electric

49 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SE150 Line Circuit Breakers SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050, UL listed HACR -Pole, UL/CSA: 150A, 600 Vac Max., IEC 947-2: 160A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Adj. Inst. Trip Range Amps UL 489 Vac UL 489 Vac 18kA 25kA Ampere Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Number Price Number Price Number Price Range SRPE0A15 $ SRPE0A20 $ SRPE0A25 $ SEDA6AT000 $82.00 SEHA6AT000 $ SRPE0A0 $ SRPE60A40 $ SRPE60A50 $ SEDA6AT0060 $82.00 SEHA6AT0060 $ /0 Cu SRPE60A60 $ TCAL18 $ SRPE100A70 $ /0 Al SRPE100A80 $ SRPE100A90 $ SEDA6AT0100 $ SEHA6AT0100 $ SRPE100A100 $ SRPE150A110 $ SRPE150A125 $ SEDA6AT0150 $ SEHA6AT0150 $ SRPE150A150 $ SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050, UL listed HACR -Pole, UL/CSA: 150A, 600 Vac Max., IEC 947-2: 160A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Adj. Inst. Trip Range Amps UL 489 Vac UL 489 Vac 65kA 100kA Ampere Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Number Price Number Price Number Price Range SRPE0A15 $ SRPE0A20 $ SRPE0A25 $ SELA6AT000 $75.00 SEPA6AT000 $ SRPE0A0 $ SRPE60A40 $ SRPE60A50 $ SELA6AT0060 $75.00 SEPA6AT0060 $ /0 Cu SRPE60A60 $ TCAL18 $ SRPE100A70 $ /0 Al SRPE100A80 $ SRPE100A90 $ SELA6AT0100 $ SEPA6AT0100 $ SRPE100A100 $ SRPE150A110 $ SRPE150A125 $ SELA6AT0150 $ SEPA6AT0150 $ SRPE150A150 $ Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -49

50 Industrial Circuit Breakers A Circuit Breakers Thermal-Magnetic Trip E150 Line Circuit Breakers Types TEB, TED, THED Noninterchangeable Trip Note: All UL listed as HACR type except 10 ampere 60 C/75 F Conductor Amperes Rating Through 100 Amperes Vac 75 C above 100 Amperes 125, 250 Vdc Single Pole Includes Cu/Al load lugs only. If line lugs are required, add suffix WL to Product Number. Type TEB Type TED Type THED GO-15B 120 Vac 125 Vdc 277 Vac 125 Vdc 47 Vac Ampere Vac 47 Vac 1 Rating Product Number List Price Product Number List Price Product Number List Price Product Number List Price Product Number List Price 10 TEB $78.50 TED $ TEB $78.50 TED11015 $82.50 TED $ THED11015 $ THED $ TEB $78.50 TED11020 $82.50 TED $ THED11020 $ THED $ TEB $78.50 TED11025 $82.50 TED $ THED11025 $ THED $ TEB11100 $78.50 TED1100 $82.50 TED11400 $ THED1100 $ THED11400 $ TEB11105 $78.50 TED1105 $ TEB $78.50 TED11040 $ TEB $78.50 TED11045 $ TEB $78.50 TED11050 $ TEB $78.50 TED11060 $ TEB $14.00 TED11070 $ TEB $14.00 TED11080 $ TEB $14.00 TED11090 $ TEB $14.00 TED11100 $ Two Pole Includes Cu/Al load lugs. For optional lugs, see page -101 and Type TEB Type TED Type THED, Hi-Break 4 GO-15B Ampere 240 Vac, 250 Vdc 480 Vac, 250 Vdc 480 Vac, 250 Vdc Rating Product Number List Price Product Number List Price Product Number List Price 10 TEB122010WL 2 $ TED124010WL 2 $ TEB122015WL $ TED124015WL $ THED124015WL $ TEB122020WL $ TED124020WL $ THED124020WL $ TEB122025WL $ TED124025WL $ THED124025WL $ TEB12200WL $ TED12400WL $ THED12400WL $ TEB12205WL $ TED12405WL $ THED12405WL $ TEB122040WL $ TED124040WL $ THED124040WL $ TEB122045WL $ TED124045WL $ THED124045WL $ TEB122050WL $ TED124050WL $ THED124050WL $ TEB122060WL $ TED124060WL $ THED124060WL $ TEB122070WL $ TED124070WL $77.00 THED124070WL $ TEB122080WL $ TED124080WL $77.00 THED124080WL $ TEB122090WL $ TED124090WL $77.00 THED124090WL $ TEB122100WL $ TED124100WL $77.00 THED124100WL $ TED124110WL $ TED124125WL $ TED124150WL $ Suitable for 10 kaic at 480 Vac, but not labeled or UL listed. 2 Not UL listed Single-pole, 15-and 20-ampere breakers are also UL listed as switching duty breakers, suitable for switching 120 Vac (TEB), 277, 47 Vac (TED, THED) fluorescent lighting loads. 4 Two-pole breaker is furnished in three-pole case. -50 BuyLog Catalog Rev. 12/04 distributed by AA Electric

51 Industrial Circuit Breakers A Circuit Breakers Thermal-Magnetic Trip E150 Line Circuit Breakers Types TEB, TED, THED Note: All UL listed as HACR type except 10 ampere 60 C/75 F Conductor Amperes Rating Through 100 Amperes Vac 75 C above 100 Amperes 125, 250 Vdc Three Pole Includes Cu/Al load lugs. For optional lugs, see page -101 and Type TEB Type TED Type THED, Hi-Break GO-15B Ampere 240 Vac 480 Vac 600 Vac 480 Vac 600 Vac Rating Product Number List Price Product Number List Price Product Number List Price Product Number Product Number List Price 10 TEB12010WL 1 $ TED14010WL 1 $77.00 TED16010WL 1 $ TEB12015WL $ TED14015WL $77.00 TED16015WL $49.00 THED14015WL THED16015WL $ TEB12020WL $ TED14020WL $77.00 TED16020WL $49.00 THED16020WL $ TEB12025WL $ TED14025WL $77.00 TED16025WL $49.00 THED16025WL $ TEB1200WL $ TED1400WL $77.00 TED1600WL $49.00 THED1400WL THED1600WL $ TEB1205WL $ TED1405WL $77.00 TED1605WL $49.00 THED1605WL $ TEB12040WL $ TED14040WL $77.00 TED16040WL $49.00 THED16040WL $ TEB12045WL $ TED14045WL $77.00 TED16045WL $49.00 THED14045WL THED16045WL $ TEB12050WL $ TED14050WL $77.00 TED16050WL $49.00 THED16050WL $ TEB12060WL $ TED14060WL $77.00 TED16060WL $ TEB12070WL $9.00 TED14070WL $ TED16070WL $54.00 THED14070WL THED16070WL $ TEB12080WL $9.00 TED14080WL $ TED16080WL $ TEB12090WL $9.00 TED14090WL $ TED16090WL $54.00 THED14090WL THED16090WL $ TEB12100WL $9.00 TED14100WL $ TED16100WL $54.00 THED14100WL THED16100WL $ TED14110WL $ TED16110WL $ THED14110WL THED16110WL $ TED14125WL $ TED16125WL $ THED14125WL THED16125WL $ TED14150WL $ TED16150WL $ THED14150WL THED16150WL $ NA TED14Y100 2 $77.00 TED16Y100 2 $ NA TED14Y150 2 $ TED16Y150 2 $ Not UL listed. 2 Includes factory-installed dummy trip. Accessories: See pages -85 to Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -51

52 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SF250 Line Circuit Breakers SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050, UL listed HACR SFH UL Current Limiting 2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac Adjustable Instantaneous Trip Ampere Range 5kA Ampere Product List Current Product List Product List Wire Rating Low High Number Price Sensor Number Price Number Price Range SRPF250A70 $ SRPF250A90 $ SRPF250A100 $ SRPF250A110 $ Cu SRPF250A125 $ SFHA24AT0250 $ TCAL29 $ SRPF250A150 $ Al SRPF250A175 $ SRPF250A200 $ SRPF250A225 $ SRPF250A250 $ SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050, UL listed HACR SFL, SFP UL Current Limiting 2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous Trip Ampere Range 65kA 100kA Ampere Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Number Price Number Price Number Price Range SRPF250A70 $ SRPF250A90 $ SRPF250A100 $ SRPF250A110 $ Cu SRPF250A125 $ SFLA24AT0250 $ SFPA24AT0250 $ TCAL29 $ SRPF250A150 $ Al SRPF250A175 $ SRPF250A200 $ SRPF250A225 $ SRPF250A250 $ SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050, UL listed HACR SFH UL Current Limiting -Pole, UL/CSA: 250A, 600 Vac Max., IEC 947-2: 250A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac Adjustable Instantaneous Trip Ampere Range 5kA Ampere Product List Current Product List Product List Wire Rating Low High Number Price Sensor Number Price Number Price Range SRPF250A70 $ SRPF250A90 $ SRPF250A100 $ SRPF250A110 $ Cu SRPF250A125 $ SFHA6AT0250 $ TCAL29 $ SRPF250A150 $ Al SRPF250A175 $ SRPF250A200 $ SRPF250A225 $ SRPF250A250 $ BuyLog Catalog Rev. 12/04 distributed by AA Electric

53 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SF250 Line Circuit Breakers SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050, UL listed HACR SFL, SFP UL Current Limiting -Pole, UL/CSA: 250A, 600 Vac Max., IEC 947-2: 250A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous Trip Ampere Range 65kA 100kA Ampere Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Number Price Number Price Number Price Range SRPF250A70 $ SRPF250A90 $ SRPF250A100 $ SRPF250A110 $ Cu SRPF250A125 $ SFLA6AT0250 $ SFPA6AT0250 $ TCAL29 $ SRPF250A150 $ Al SRPF250A175 $ SRPF250A200 $ SRPF250A225 $ SRPF250A250 $ Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -5

54 Industrial Circuit Breakers A Circuit Breakers Thermal-Magnetic Trip F225 Line Circuit Breakers Types TFJ, TFK, THFK F225 Line Circuit Breakers Amperes TFJ Noninterchangeable Trip, suitable for reverse feed A TFK, THFK Interchangeable Trip, not suitable for reverse feed 480 or 600 Vac 250 Vdc Note: All TFJ, TFK and THFK breakers are UL listed as HACR Type TFK Type TFJ Noninterchangeable Trip Adjustable Instantaneous Complete Breaker Complete Breaker Trip Ampere Range 480 Vac Max 600 Vac Max GO-15B Ampere Rating Low High Product Number List Price Product Number List Price Copper/Aluminum Lugs Wire Size Two-Pole Three-Pole TFJ224070WL $ TFJ26070WL $ TFJ224080WL $ TFJ26080WL $ TFJ224090WL $ TFJ26090WL $ TFJ224100WL $ TFJ26100WL $ TFJ224110WL $ TFJ26110WL $ TFJ224125WL $ TFJ26125WL $ TCAL Cu/Al TFJ224150WL $ TFJ26150WL $ TFJ224175WL $ TFJ26175WL $ TFJ224200WL $ TFJ26200WL $ TFJ224225WL $ TFJ26225WL $ TFJ26250WL $ Types TFK, THFK Interchangeable Trip GO-15B Terminal Lugs for Complete Circuit Breaker Includes Line and Load Lugs Trip Unit Only Frame Only Front Connection (Copper/Aluminum) 2 Adjustable Instantaneous Standard High-Break Product Number Ampere Trip Ampere Range Product List Product List Use with Standard List Product List (Order 1 line and List Wire Rating Low High Number Price Number Price and Hi-Break Frames Price Number Price 1 load per pole) Price Size Two-Pole, 480 Vac Max., 250 Vdc Max TFK224070WL $ THFK224070WL $ TFK226T070 $ TFK224080WL $ THFK224080WL $ TFK226T080 $7.00 TFK224F000 $ TFK224090WL $ THFK224090WL $ TFK226T090 $7.00 Standard TFK224100WL $ THFK224100WL $ TFK226T100 $7.00 Frame TFK224110WL $ THFK224110WL $ TFK226T110 $ TFK224125WL $ THFK224125WL $ TFK226T125 $7.00 TCAL24 $ Cu/Al TFK224150WL $ THFK224150WL $ TFK226T150 $ TFK224175WL $ THFK224175WL $ TFK226T175 $7.00 THFK224F000 $ TFK224200WL $ THFK224200WL $ TFK226T200 $7.00 Hi-Break TFK224225WL $ THFK224225WL $ TFK226T225 $7.00 Frame Three-Pole, 600 Vac Max., 250 Vdc Max TFK26070WL $ THFK26070WL $ TFK26T070 $ TFK26080WL $ THFK26080WL $ TFK26T080 $ TFK26F000 $ TFK26090WL $ THFK26090WL $ TFK26T090 $ Standard TFK26100WL $ THFK26100WL $ TFK26T100 $ Frame TFK26110WL $ THFK26110WL $ TFK26T110 $ TFK26125WL $ THFK26125WL $ TFK26T125 $ TCAL24 $ Cu/Al TFK26150WL $ THFK26150WL $ TFK26T150 $ TFK26175WL $ THFK26175WL $ TFK26T175 $ THFK26F000 $ TFK26200WL $ THFK26200WL $ TFK26T200 $ Hi-Break TFK26225WL $ THFK26225WL $ TFK26T225 $ Frame TFK26TM1225 $ Mag TFK26TM2225 $ Only 1 TC024 load end. Wire range #4-00 copper only. 2 For optional lug see page Accessories: See pages -85 to BuyLog Catalog Rev. 12/04 distributed by AA Electric

55 Industrial Circuit Breakers A Circuit Breakers Thermal-Magnetic Trip Q Line Circuit Breakers Types TJD Two-Pole TJD GO-15F TJD Lug-lug 240 Vac 1 22 kaic Ampere Rating Product Number List Price TJD422250WL $XXXX.00 TJD42200WL $XXXX.00 TJD42250WL $XXXX.00 TJD422400WL $XXXX.00 TJD422Y400 $XXXX.00 1 Includes line and load lugs. For optional configurations, see page -21. Three-Pole TJD TJD Lug-lug 240 Vac 1 22 kaic GO-15F Ampere Rating Product Number List Price 250 TJD42250WL 2 $ TJD4200WL 2 $ TJD4250WL 2 $ TJD42400WL 2 $ Molded Case Switch TJD42Y400 2 $ Includes line and load lugs. For optional configurations, see page TJD uses same accessories as J600 line. TJD not listed HACR. TJD4200WL See page -4 for size and ratings. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -55

56 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SG600 Digital, Solid-State Spectra RMS Breakers SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous 65kA (240 Vac) 5kA Ampere Trip Ampere Range Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Number Price Range SRPG400A125 $ pole lug kit SRPG400A150 $ (2) 2/0-500 Cu SRPG400A175 $ SGDA22AT $ SGHA26AT0400 $ TCLK265 2 $28.00 or SRPG400A200 $ (1) Cu SRPG400A225 $ SRPG400A250 $ pole lug kit SRPG400A00 $ SGDA2AT $ SGHA6AT0400 $28.00 (2) 2/0-500 Al SRPG400A50 $ TCLK65 2 $42.00 or SRPG400A400 $ (1) Al SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous 65kA 100kA Ampere Trip Ampere Range Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Number Price Range SRPG400A125 $ pole lug kit SRPG400A150 $ (2) 2/0-500 Cu SRPG400A175 $ SGLA26AT0400 $ SGPA26AT0400 $ TCLK265 2 $28.00 or SRPG400A200 $ (1) Cu SRPG400A225 $ SRPG400A250 $ pole lug kit SRPG400A00 $ SGLA6AT0400 $ SGPA6AT0400 $ (2) 2/0-500 Al SRPG400A50 $ TCLK65 2 $42.00 or SRPG400A400 $ (1) Al SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting UL/CSA: 600A, 600 Vac Max., IEC 947-2: 60A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous 5kA 65kA Ampere Trip Ampere Range Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Number Price Range SRPG600A250 $ pole lug kit SRPG600A00 $ SGHA26AT0600 $ SGLA26AT0600 $ (2) 2/0-500 Cu SRPG600A50 $ TCLK265 2 $28.00 or SRPG600A400 $ (1) Cu SRPG600A450 $ pole lug kit SRPG600A500 $ SGHA6AT0600 $54.00 SGLA6AT0600 $ (2) 2/0-500 Al SRPG600A600 $ TCLK65 2 $42.00 or (1) Al 1 Rated 240 Vac max. 2 Order one kit for either line or load end; two kits required for both. -56 BuyLog Catalog Rev. 12/04 distributed by AA Electric

57 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SG600 Digital, Solid-State Spectra RMS Breakers SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting UL/CSA: 600A, 600 Vac Max., IEC 947-2: 60A, 690 Vac Max. Adjustable Instantaneous GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac 100kA Ampere Trip Ampere Range Product List Current Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Range SRPG600A250 $ pole lug kit SRPG600A00 $ SGPA26AT0600 $ (2) 2/0-500 Cu SRPG600A50 $ TCLK265 1 $28.00 or SRPG600A400 $ (1) Cu SRPG600A450 $ pole lug kit SRPG600A500 $ SGPA6AT0600 $ (2) 2/0-500 Al SRPG600A600 $ TCLK65 1 $42.00 or (1) Al 1 Order one kit for either line or load end; two kits required for both. SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting 100% UL Rated, -Pole: 400A, 600 Vac Max.; IEC 947-2: 400A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous 5kAIC 65kAIC Ampere Trip Ampere Range Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Number Price Range SRPG400A125 $ SRPG400A150 $ (2) 2/0-500 Cu SRPG400A175 $ or SRPG400A200 $ (1) Cu SRPG400A225 $ SGHH6AT0400 $ SGLL6AT0400 $ TCLK65 $ SRPG400A250 $ SRPG400A00 $ (2) 2/0-500 Al SRPG400A50 $ or SRPG400A400 $ (1) Al SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting 100% UL Rated, -Pole: 400A, 600 Vac Max.; IEC 947-2: 400A, 690 Vac Max. Adjustable Instantaneous GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac 100kAIC Ampere Trip Ampere Range Product List Current Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Range SRPG400A125 $ SRPG400A150 $ (2) 2/0-500 Cu SRPG400A175 $ or SRPG400A200 $ (1) Cu SRPG400A225 $ SGPP6AT0400 $ TCLK65 $ SRPG400A250 $ SRPG400A00 $ (2) 2/0-500 Al SRPG400A50 $ or SRPG400A400 $ (1) Al Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -57

58 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SG600 Digital, Solid-State Spectra RMS Breakers SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting 100% UL Rated, -Pole: 600A, 600 Vac Max.; IEC 947-2: 60A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous 5kAIC 65kAIC Ampere Trip Ampere Range Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Number Price Range SRPG600A250 $ SRPG600A00 $ (2) 2/0-500 Cu SRPG600A50 $ or (1) Cu SRPG600A400 $ SGHH6AT0600 $ SGLL6AT0600 $ TCLK65 $ SRPG600A450 $ (2) 2/0-500 Al SRPG600A500 $ (1) Al SRPG600A600 $ SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting 100% UL Rated, -Pole: 600A, 600 Vac Max.; IEC 947-2: 60A, 690 Vac Max. Adjustable Instantaneous GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac 100kAIC Ampere Trip Ampere Range Product List Current Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Range SRPG600A250 $ SRPG600A00 $ (2) 2/0-500 Cu SRPG600A50 $ or (1) Cu SRPG600A400 $ SGPP6AT0600 $ TCLK65 $ SRPG600A450 $ (2) 2/0-500 Al SRPG600A500 $ or (1) Al SRPG600A600 $ BuyLog Catalog Rev. 12/04 distributed by AA Electric

59 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SG600 with MicroVersaTrip Plus and PM MicroVersaTrip Plus, Standard UL Rated SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting; -Pole, UL/CSA: 600 Vac Max., IEC 947-2: 60A, 690 Vac Max. Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 GO-15S Terminal Lugs for Front connection (Cu/Al) Current Trip 5kA 65kA 100kA Sensor Function Product Number List Price Product Number List Price Product Number List Price Product Number List Price Wire Range LIT SGHB6BA0150 $ SGLB6BA0150 $ SGPB6BA0150 $ LSIT SGHB6BB0150 $ SGLB6BB0150 $ SGPB6BB0150 $ LIGT 1 SGHB6BC0150 $ SGLB6BC0150 $ SGPB6BC0150 $ LSIGT 1 SGHB6BD0150 $ SGLB6BD0150 $ SGPB6BD0150 $ LIT-CP 2 SGHB6BE0150 $ SGLB6BE0150 $ SGPB6BE0150 $ (2) 2/0-500 Cu LSIT-CP 2 SGHB6BF0150 $ SGLB6BF0150 $ SGPB6BF0150 $ or LIT SGHB6BA0400 $ SGLB6BA0400 $ SGPB6BA0400 $ Pole $42.00 (1) Cu LSIT SGHB6BB0400 $ SGLB6BB0400 $ SGPB6BB0400 $ lug kit LIGT 1 SGHB6BC0400 $ SGLB6BC0400 $ SGPB6BC0400 $ TCLK65 LSIGT 1 SGHB6BD0400 $ SGLB6BD0400 $ SGPB6BD0400 $ (2) 2/0-500 Al LIT-CP 2 SGHB6BE0400 $ SGLB6BE0400 $ SGPB6BE0400 $ or LSIT-CP 2 SGHB6BF0400 $ SGLB6BF0400 $ SGPB6BF0400 $ (1) Al LIT SGHB6BA0600 $ SGLB6BA0600 $ SGPB6BA0600 $ LSIT SGHB6BB0600 $ SGLB6BB0600 $ SGPB6BB0600 $ LIGT 1 SGHB6BC0600 $ SGLB6BC0600 $ SGPB6BC0600 $ LSIGT 1 SGHB6BD0600 $ SGLB6BD0600 $ SGPB6BD0600 $ LIT-CP 2 SGHB6BE0600 $ SGLB6BE0600 $ SGPB6BE0600 $ LSIT-CP 2 SGHB6BF0600 $ SGLB6BF0600 $ SGPB6BF0600 $ MicroVersaTrip Plus, 100% UL Rate 4 SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting; -Pole, UL/CSA: 600 Vac Max., IEC 947-2: 60A, 690 Vac Max. Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 GO-15S Terminal Lugs for Front connection (Cu/Al) Current Trip 5kA 65kA 100kA Sensor Function Product Number List Price Product Number List Price Product Number List Price Product Number List Price Wire Range LIT SGHH6BA0150 $ SGLL6BA0150 $ SGPP6BA0150 $ LSIT SGHH6BB0150 $ SGLL6BB0150 $ SGPP6BB0150 $ LIGT 1 SGHH6BC0150 $ SGLL6BC0150 $ SGPP6BC0150 $ LSIGT 1 SGHH6BD0150 $ SGLL6BD0150 $ SGPP6BD0150 $ LIT-CP 2 SGHH6BE0150 $ SGLL6BE0150 $ SGPP6BE0150 $ (2) 2/0-500 Al LSIT-CP 2 SGHH6BF0150 $ SGLL6BF0150 $ SGPP6BF0150 $ or LIT SGHH6BA0400 $ SGLL6BA0400 $ SGPP6BA0400 $ Pole $42.00 (1) Al LSIT SGHH6BB0400 $ SGLL6BB0400 $ SGPP6BB0400 $ lug kit 400 LIGT 1 SGHH6BC0400 $ SGLL6BC0400 $ SGPP6BC0400 $ TCLK65 LSIGT 1 SGHH6BD0400 $ SGLL6BD0400 $ SGPP6BD0400 $ (2) 2/0-500 Cu LIT-CP 2 SGHH6BE0400 $ SGLL6BE0400 $ SGPP6BE0400 $ or LSIT-CP 2 SGHH6BF0400 $ SGLL6BF0400 $ SGPP6BF0400 $ (1) Cu LIT SGHH6BA0600 $ SGLL6BA0600 $ SGPP6BA0600 $ LSIT SGHH6BB0600 $ SGLL6BB0600 $ SGPP6BB0600 $ LIGT SGHH6BC0600 $ SGLL6BC0600 $ SGPP6BC0600 $ LSIGT SGHH6BD0600 $ SGLL6BD0600 $ SGPP6BD0600 $ LIT-CP 4 SGHH6BE0600 $ SGLL6BE0600 $ SGPP6BE0600 $ LSIT-CP 4 SGHH6BF0600 $ SGLL6BF0600 $ SGPP6BF0600 $ For grounded neutral systems (1**/w or **4w) a neutral current sensor is required. Refer to page For +24 Vdc Control Power Accessories refer to pages -106 to Order one kit for either line or load end; two kits required for both % UL rated supplied with back-connected assembly which increases breaker depth. Refer to outline drawing for details. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -59

60 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS with MicroVersaTrip PM Trip Units 1 MicroVersaTrip PM, Standard UL Rated (No Protective Relays) SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting; -Pole, UL/CSA: 600 Vac Max., IEC 947-2: 60A, 690 Vac Max. Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 Terminal Lugs for Front connection (Cu/Al) Current Trip 5kA List Price, 65kA List Price, 100kA List Price, List Price, Sensor Function Product Number GO-15PM Product Number GO-15PM Product Number GO-15PM Product Number GO-15S Wire Range LIT SGHB6CA0150 $ SGLB6CA0150 $ SGPB6CA0150 $ LSIT SGHB6CB0150 $ SGLB6CB0150 $ SGPB6CB0150 $ (2) 2/0-500 Cu LIGT 2 SGHB6CC0150 $ SGLB6CC0150 $ SGPB6CC0150 $ or LSIGT 2 SGHB6CD0150 $ SGLB6CD0150 $ SGPB6CD0150 $ (1) Cu LIT SGHB6CA0400 $ SGLB6CA0400 $ SGPB6CA0400 $ Pole $42.00 LSIT SGHB6CB0400 $ SGLB6CB0400 $ SGPB6CB0400 $ lug kit LIGT 2 SGHB6CC0400 $ SGLB6CC0400 $ SGPB6CC0400 $ TCLK65 (2) 2/0-500 Al LSIGT 2 SGHB6CD0400 $ SGLB6CD0400 $ SGPB6CD0400 $ or LIT SGHB6CA0600 $ SGLB6CA0600 $ SGPB6CA0600 $ (1) Al LSIT SGHB6CB0600 $ SGLB6CB0600 $ SGPB6CB0600 $ LIGT 2 SGHB6CC0600 $ SGLB6CC0600 $ SGPB6CC0600 $ LSIGT 2 SGHB6CD0600 $ SGLB6CD0600 $ SGPB6CD0600 $ MicroVersaTrip PM, 100% UL Rated 4 (No Protective Relays) SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting; -Pole, UL/CSA: 600 Vac Max., IEC 947-2: 60A, 690 Vac Max. Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 Terminal Lugs for Front connection (Cu/Al) Current Trip 5kA List Price, 65kA List Price, 100kA List Price, List Price, Sensor Function Product Number GO-15PM Product Number GO-15PM Product Number GO-15PM Product Number GO-15S Wire Range LIT SGHH6CA0150 $ SGLL6CA0150 $ SGPP6CA0150 $ LSIT SGHH6CB0150 $79.00 SGLL6CB0150 $ SGPP6CB0150 $ (2) 2/0-500 Cu LIGT 2 SGHH6CC0150 $ SGLL6CC0150 $ SGPP6CC0150 $ or LSIGT 2 SGHH6CD0150 $ SGLL6CD0150 $ SGPP6CD0150 $ (1) Cu LIT SGHH6CA0400 $ SGLL6CA0400 $ SGPP6CA0400 $ Pole $42.00 LSIT SGHH6CB0400 $79.00 SGLL6CB0400 $ SGPP6CB0400 $ lug kit LIGT 2 SGHH6CC0400 $ SGLL6CC0400 $ SGPP6CC0400 $ TCLK65 (2) 2/0-500 Al LSIGT 2 SGHH6CD0400 $ SGLL6CD0400 $ SGPP6CD0400 $ or LIT SGHH6CA0600 $ SGLL6CA0600 $ SGPP6CA0600 $ (1) Al LSIT SGHH6CB0600 $86.00 SGLL6CB0600 $ SGPP6CB0600 $ LIGT 2 SGHH6CC0600 $ SGLL6CC0600 $ SGPP6CC0600 $ LSIGT 2 SGHH6CD0600 $ SGLL6CD0600 $ SGPP6CD0600 $ MicroVersaTrip Plus and PM Rating Plug Selection All Plugs List Price, $ GO-15S Circuit Breaker Sensor Rating Plug Rating Plug Frame Rating Rating (Amperes) Product No SRPG150B60 80 SRPG150B SRPG150B SRPG150B SRPG150B SRPG400B SRPG400B200 SGHB, SGHH, SGLB, 225 SRPG400B225 SGLL, SGPB, SGPP 250 SRPG400B SRPG400B00 50 SRPG400B SRPG400B SRPG600B SRPG600B SRPG600B SRPG600B SRPG600B600 1 MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages -106 to For grounded neutral systems (1**/w or **4w) a neutral current sensor is required. Refer to page Order one kit for either line or load end; two kits required for both % UL rated supplied with back-connected assembly which increases breaker depth. Refer to outline drawing for details. -60 BuyLog Catalog Rev. 12/04 distributed by AA Electric

61 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS with MicroVersaTrip PM Trip Units 1 MicroVersaTrip PM, Standard UL Rated (With Protective Relaying) SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting; -Pole, UL/CSA: 600 Vac Max., IEC 947-2: 60A, 690 Vac Max. Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 Terminal Lugs for Front connection (Cu/Al) Current Trip 5kA List Price, 65kA List Price, 100kA List Price, List Price, Sensor Function Product Number GO-15PM Product Number GO-15PM Product Number GO-15PM Product Number GO-15S Wire Range LIT SGHB6DA0150 $ SGLB6DA0150 $ SGPB6DA0150 $72.00 LSIT SGHB6DB0150 $ SGLB6DB0150 $ SGPB6DB0150 $ (2) 2/0-500 Cu LIGT 2 SGHB6DC0150 $ SGLB6DC0150 $ SGPB6DC0150 $ or LSIGT 2 SGHB6DD0150 $ SGLB6DD0150 $ SGPB6DD0150 $ (1) Cu LIT SGHB6DA0400 $ SGLB6DA0400 $ SGPB6DA0400 $ Pole $42.00 LSIT SGHB6DB0400 $ SGLB6DB0400 $ SGPB6DB0400 $ lug kit LIGT 2 SGHB6DC0400 $ SGLB6DC0400 $ SGPB6DC0400 $ TCLK65 (2) 2/0-500 Al LSIGT 2 SGHB6DD0400 $ SGLB6DD0400 $ SGPB6DD0400 $ or LIT SGHB6DA0600 $ SGLB6DA0600 $ SGPB6DA0600 $ (1)6-600 Al LSIT SGHB6DB0600 $ SGLB6DB0600 $ SGPB6DB0600 $ LIGT 2 SGHB6DC0600 $ SGLB6DC0600 $ SGPB6DC0600 $ LSIGT 2 SGHB6DD0600 $ SGLB6DD0600 $ SGPB6DD0600 $ MicroVersaTrip PM, 100% UL Rated 4 (With Protective Relays) SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 SGL, SGP UL Current Limiting; -Pole, UL/CSA: 600 Vac Max., IEC 947-2: 60A, 690 Vac Max. Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 Terminal Lugs for Front connection (Cu/Al) Current Trip 5kA List Price, 65kA List Price, 100kA List Price, List Price, Sensor Function Product Number GO-15PM Product Number GO-15PM Product Number GO-15PM Product Number GO-15S Wire Range LIT SGHH6DA0150 $ SGLL6DA0150 $ SGPP6DA0150 $ LSIT SGHH6DB0150 $ SGLL6DB0150 $ SGPP6DB0150 $ (2) 2/0-500 Cu LIGT 2 SGHH6DC0150 $ SGLL6DC0150 $ SGPP6DC0150 $ or LSIGT 2 SGHH6DD0150 $ SGLL6DD0150 $ SGPP6DD0150 $ (1) Cu LIT SGHH6DA0400 $ SGLL6DA0400 $ SGPP6DA0400 $ Pole $42.00 LSIT SGHH6DB0400 $ SGLL6DB0400 $ SGPP6DB0400 $ lug kit LIGT 2 SGHH6DC0400 $ SGLL6DC0400 $ SGPP6DC0400 $ TCLK65 (2) 2/0-500 Al LSIGT 2 SGHH6DD0400 $ SGLL6DD0400 $ SGPP6DD0400 $ or LIT SGHH6DA0600 $ SGLL6DA0600 $ SGPP6DA0600 $ (1) Al LSIT SGHH6DB0600 $ SGLL6DB0600 $ SGPP6DB0600 $ LIGT 2 SGHH6DC0600 $ SGLL6DC0600 $ SGPP6DC0600 $ LSIGT 2 SGHH6DD0600 $ SGLL6DD0600 $ SGPP6DD0600 $ MicroVersaTrip Plus and PM Rating Plug Selection All Plugs List Price, $ GO-15S Circuit Breaker Sensor Rating Plug Rating Plug Frame Rating Rating (Amperes) Product No SRPG150B60 80 SRPG150B SRPG150B SRPG150B SRPG150B SRPG400B SRPG400B200 SGHB, SGHH, SGLB, 225 SRPG400B225 SGLL, SGPB, SGPP 250 SRPG400B SRPG400B00 50 SRPG400B SRPG400B SRPG600B SRPG600B SRPG600B SRPG600B SRPG600B600 1 MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages -106 to For grounded neutral systems (1**/w or **4w) a neutral current sensor is required. Refer to page Order one kit for either line or load end; two kits required for both % UL rated supplied with back-connected assembly which increases breaker depth. Refer to outline drawing for details. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -61

62 Industrial Circuit Breakers A Circuit Breakers Thermal-Magnetic Trip J600 Line Circuit Breakers Types TJJ, TJK, THJK TYPE TJK Type TJJ Noninterchangeable Trip (includes Line and Load Lugs), suitable for reverse feed 2-Pole, 400 Ampere Frame -Pole, 400 Ampere Frame Terminal Lugs for Front Adjustable Instantaneous 600 Vac, 250 Vdc 600 Vac Connection (Cu/Al) Ampere Trip Ampere Range Product List Product List Copper/ Wire Rating Low High Number Price Number Price Aluminum Lugs Size Frame GO-15B TJJ426125WL $ TJJ46125WL $ TJJ426150WL $ TJJ46150WL $ TJJ426175WL $ TJJ46175WL $ TJJ426200WL $ TJJ46200WL $ TCAL TJJ426225WL $ TJJ46225WL $ Included in (1) or TJJ426250WL $ TJJ46250WL $ price of (2) 2/0-250 Cu/Al TJJ42600WL $ TJJ4600WL $ breaker TJJ42650WL $ TJJ4650WL $ TJJ426400WL $ TJJ46400WL $ Types TJK, THJK Interchangeable Trip, not suitable for reverse feed Complete Circuit Breaker Terminal Lugs for Front Includes Line and Load Lugs Connection (Cu/Al) 1 GO-15B Adjustable Instantaneous Trip Unit Only. Use Product Number Ampere Trip Ampere Range Standard List Hi-Break List Frame Only List with Standard and List (Order 2 List Rating Low High Product Number Price Product Number Price Product Number Price Hi-Break Frames Price per pole) Price Wire Size 400A Frame Two-Pole TJK426125WL $ THJK426125WL $ TJK426T125 $ TJK426150WL $ THJK426150WL $ TJK426F000 $ TJK426T150 $ TJK426175WL $ THJK426175WL $ Standard TJK426T175 $ TJK426200WL $ THJK426200WL $ Frame TJK426T200 $ TJK426225WL $ THJK426225WL $ TJK426T225 $ TJK426250WL $ THJK426250WL $ TJK426T250 $ TCAL4 2 $14.00 (1) TJK42600WL $ THJK42600WL $ TJK426T00 $ or TJK42650WL $ THJK42650WL $ THJK426F000 $ TJK426T50 $ (2) 2/0-250 Cu/Al TJK426400WL $ THJK426400WL $ Hi-Break TJK426T400 $ A Frame Three-Pole TJK46125WL $ THJK46125WL $ TJK46T125 $ TJK46150WL $ THJK46150WL $ TJK46F000 $ TJK46T150 $ TJK46175WL $ THJK46175WL $ Standard TJK46T175 $ TJK46200WL $ THJK46200WL $ Frame TJK46T200 $ TJK46225WL $ THJK46225WL $ TJK46T225 $ TCAL4 2 $14.00 (1) TJK46250WL $ THJK46250WL $ TJK46T250 $ or TJK4600WL $ THJK4600WL $ TJK46T00 $ (2) 2/0-250 Cu/Al TJK4650WL $ THJK4650WL $ THJK46F000 $ TJK46T50 $ TJK46400WL $ THJK46400WL $ Hi-Break TJK46T400 $ TJK46TM1400 $ Mag TJK46TM2400 $ Only TJK46TM400 $ For optional lugs, see page Not UL listed. Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47 List Price $26.00, GO-15B. Accessories: See pages -85 to BuyLog Catalog Rev. 12/04 distributed by AA Electric

63 Industrial Circuit Breakers A Circuit Breakers Thermal-Magnetic Trip J600 Line Circuit Breakers Types TJJ, TJK, THJK Types TJK, THJK Interchangeable Trip Complete Circuit Breaker Terminal Lugs for Front Includes Line and Load Lugs Connection (Cu/Al) 1 GO-15S Adjustable Instantaneous Trip Unit Only. Use Product Number Ampere Trip Ampere Range Standard List Hi-Break List Frame Only List with Standard and List (Order 2 List Rating Low High Product Number Price Product Number Price Product Number Price Hi-Break Frames Price per pole) Price Wire Size 600A Frame Two-Pole TJK626250WL $ THJK626250WL $ TJK626T250 $ TCAL4 2 $14.00 (1) TJK62600WL $ THJK62600WL $ TJK626F000 $ TJK626T00 $ or TJK62650WL $ THJK62650WL $ Standard TJK626T50 $ (2) 2/0-250 Cu/Al TJK626400WL $ THJK626400WL $ Frame TJK626T400 $ TJK626450WL $ THJK626450WL $ THJK626F000 TJK626T450 $ (2) 4/0-50 Cu TJK626500WL $ THJK626500WL $ Hi-Break $ TJK626T500 $ TCAL6 $2.00 or TJK626600WL $ THJK626600WL $ Frame TJK626T600 $ (2) Al 600A Frame Three-Pole TJK66250WL $59.00 THJK66250WL $ TJK66T250 $ TCAL4 2 $14.00 (1) TJK6600WL $59.00 THJK6600WL $ TJK66F000 $ TJK66T00 $ or TJK6650WL $59.00 THJK6650WL $ Standard TJK66T50 $ (2) 2/0-250 Cu/Al TJK66400WL $59.00 THJK66400WL $ Frame TJK66T400 $ TJK66450WL $59.00 THJK66450WL $ THJK66F000 TJK66T450 $ (2) 4/0-50 Cu TJK66500WL $59.00 THJK66500WL $ Hi-Break $ TJK66T500 $ TCAL6 $2.00 or TJK66600WL $59.00 THJK66600WL $ Frame TJK66T600 $ (2) Al TJK66TM1600 $ Mag Only TJK66TM2600 $ For optional lugs, see page Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47 List Price $26.00, GO-15B. Not UL listed. Accessories: See pages -85 to Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -6

64 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous 50kA 65kA Ampere Trip Ampere Range Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Number Price Range SRPK800A00 $ SRPK800A400 $ SKHA26AT0800 $77.00 SKLA26AT0800 $ () /0-500 Cu SRPK800A500 $ TCAL81 $ SRPK800A600 $ SRPK800A700 $ SKHA6AT0800 $42.00 SKLA6AT0800 $ () /0-500 Al SRPK800A800 $ SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max. Adjustable Instantaneous GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac 100kA Ampere Trip Ampere Range Product List Current Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Range SRPK800A00 $ SRPK800A400 $ SKPA26AT0800 $ () /0-500 Cu SRPK800A500 $ TCAL81 $ SRPK800A600 $ SRPK800A700 $ SKPA6AT0800 $ () /0-500 Al SRPK800A800 $ SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous 5kA 65kA Ampere Trip Ampere Range Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Number Price Range SRPK1200A600 $ SRPK1200A700 $ SKHA26AT1200 $ SKLA26AT1200 $ (4) Cu SRPK1200A800 $ TCAL125 $ SRPK1200A1000 $ SKHA6AT1200 $ SKLA6AT1200 $ (4) Al SRPK1200A1200 $ SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 4050 UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. Adjustable Instantaneous GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac 100kA Ampere Trip Ampere Range Product List Current Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Range SRPK1200A600 $ SRPK1200A700 $ SKPA26AT1200 $ (4) Cu SRPK1200A800 $ TCAL125 $ SRPK1200A1000 $ SKPA6AT1200 $ (4) Al SRPK1200A1200 $ Suitable for 500 kcmil copper for voltage drop consideration, 1200 ampere max. rating. -64 BuyLog Catalog Rev. 12/04 distributed by AA Electric

65 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR % UL Rated, -Pole: 800A, 600 Vac Max.; IEC 947-2: 800A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous 50kA 65kA Ampere Trip Ampere Range Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Number Price Range SRPK800A00 $ SRPK800A400 $ SRPK800A500 $ SKHH6AT0800 $ SKLL6AT0800 $ TCAL81 $ SRPK800A600 $ SRPK800A700 $ SRPK800A800 $ SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR % UL Rated, -Pole: 800A, 600 Vac Max.; IEC 947-2: 800A, 690 Vac Max. Adjustable Instantaneous () /0-500 Cu () /0-500 Al GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac 100kA Ampere Trip Ampere Range Product List Current Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Range SRPK800A00 $ SRPK800A400 $ SRPK800A500 $ SKPP6AT0800 $ TCAL81 $ SRPK800A600 $ SRPK800A700 $ SRPK800A800 $ () /0-500 Cu () /0-500 Al SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR % UL Rated, -Pole: 1200A, 600 Vac Max.; IEC 947-2: 1000A, 690 Vac Max. GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac UL 489 Vac Adjustable Instantaneous 50kA 65kA Ampere Trip Ampere Range Product List Current Product List Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Number Price Range SRPK1200A600 $ SRPK1200A700 $ SRPK1200A800 $ SKHH6AT1000 $ SKLL6AT1000 $ TCAL125 $ SRPK1200A1000 $ SRPK1200A1200 $ SKHH6AT $ SKLL6AT $ SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR % UL Rated, -Pole: 1200A, 600 Vac Max.; IEC 947-2: 1000A, 690 Vac Max. Adjustable Instantaneous (4) Cu 2 (4) Al GO-15S Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) UL 489 Vac 100kA Ampere Trip Ampere Range Product List Current Product List Product List Wire Rating Low High Number Price Sensor Poles Number Price Number Price Range SRPK1200A600 $ SRPK1200A700 $ SRPK1200A800 $ SKPP6AT1000 $ TCAL125 $ SRPK1200A1000 $ SRPK1200A1200 $ SKPP6AT $ % UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawings for details. 2 Suitable for 500 kcmil copper for voltage drop consideration, 1200A max. rating. (4) Cu 2 (4) Al Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -65

66 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SK1200 with MicroVersaTrip Plus and PM MicroVersaTrip Plus, Standard UL Rated SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 GO-15S Terminal Lugs for Front connection (Cu/Al) Current Trip 50kA 65kA 100kA Sensor Function Product Number List Price Product Number List Price Product Number List Price Product Number List Price Wire Range LIT SKHB6BA0800 $ SKLB6BA0800 $ SKPB6BA0800 $ LSIT SKHB6BB0800 $ SKLB6BB0800 $ SKPB6BB0800 $ LIGT 1 SKHB6BC0800 $ SKLB6BC0800 $ SKPB6BC0800 $ TCAL81 $47.00 () /0-500 Cu LSIGT 1 SKHB6BD0800 $ SKLB6BD0800 $ SKPB6BD0800 $ () /0-500 Al LIT-CP 2 SKHB6BE0800 $ SKLB6BE0800 $ SKPB6BE0800 $ LSIT-CP 2 SKHB6BF0800 $ SKLB6BF0800 $ SKPB6BF0800 $ LIT SKHB6BA1200 $ SKLB6BA1200 $ SKPB6BA1200 $ LSIT SKHB6BB1200 $ SKLB6BB1200 $ SKPB6BB1200 $ LIGT 1 SKHB6BC1200 $ SKLB6BC1200 $ SKPB6BC1200 $ TCAL125 $76.00 (4) Cu LSIGT 1 SKHB6BD1200 $ SKLB6BD1200 $ SKPB6BD1200 $ (4) Al LIT-CP 2 SKHB6BE1200 $ SKLB6BE1200 $ SKPB6BE1200 $ LSIT-CP 2 SKHB6BF1200 $ SKLB6BF1200 $ SKPB6BF1200 $ MicroVersaTrip Plus, 100% UL Rated 4 SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 GO-15S Terminal Lugs for Front connection (Cu/Al) Current Trip 50kA 65kA 100kA Sensor Function Product Number List Price Product Number List Price Product Number List Price Product Number List Price Wire Range LIT SKHH6BA0800 $ SKLL6BA0800 $ SKPP6BA0800 $ LSIT SKHH6BB0800 $ SKLL6BB0800 $ SKPP6BB0800 $ LIGT 1 SKHH6BC0800 $ SKLL6BC0800 $ SKPP6BC0800 $ TCAL81 $47.00 () /0-500 Cu LSIGT 1 SKHH6BD0800 $ SKLL6BD0800 $ SKPP6BD0800 $ () /0-500 Al LIT-CP 2 SKHH6BE0800 $ SKLL6BE0800 $ SKPP6BE0800 $ LSIT-CP 2 SKHH6BF0800 $ SKLL6BF0800 $ SKPP6BF0800 $ LIT SKHH6BA1000 $ SKLL6BA1000 $ SKPP6BA1000 $ LSIT SKHH6BB1000 $ SKLL6BB1000 $ SKPP6BB1000 $ LIGT 1 SKHH6BC1000 $ SKLL6BC1000 $ SKPP6BC1000 $ LSIGT 1 SKHH6BD1000 $ SKLL6BD1000 $ SKPP6BD1000 $ LIT-CP 2 SKHH6BE1000 $ SKLL6BE1000 $ SKPP6BE1000 $ LSIT-CP 2 SKHH6BF1000 $ SKLL6BF1000 $ SKPP6BF1000 $ TCAL125 $76.00 (4) Cu LIT SKHH6BA1200 $ SKLL6BA1200 $ SKPP6BA1200 $ (4) Al LSIT SKHH6BB1200 $ SKLL6BB1200 $ SKPP6BB1200 $ LIGT 1 SKHH6BC1200 $ SKLL6BC1200 $ SKPP6BC1200 $ LSIGT 1 SKHH6BD1200 $ SKLL6BD1200 $ SKPP6BD1200 $ LIT-CP 2 SKHH6BE1200 $ SKLL6BE1200 $ SKPP6BE1200 $ LSIT-CP 2 SKHH6BF1200 $ SKLL6BF1200 $ SKPP6BF1200 $ MicroVersaTrip Plus and PM Rating Plug Selection All Plugs List Price, $ GO-15S 00 SRPK800B SRPK800B SRPK800B SRPK800B600 SKHB, SKHH, SKLB, 700 SRPK800B700 SKLL, SKPB, SKPP 800 SRPK800B SRPK1200B SRPK1200B SRPK1200B SRPK1200B SRPK1200B For grounded neutral systems (1**/w or **4w) a neutral current sensor is required. Refer to page For +24 Vdc Control Power Accessories refer to pages -106 to Suitable for 500 kcmil copper, 1200A max. rating % UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 168D1678 Sh2 for details. 5 For ground fault neutral current sensor, use 1200A rating. 6 Not suitable for use with 100% rated, 1000A breaker frame. -66 BuyLog Catalog Rev. 12/04 distributed by AA Electric

67 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SK1200 with MicroVersaTrip PM 1 MicroVersaTrip PM, Standard UL Rated (No Protective Relays) SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 Terminal Lugs for Front connection (Cu/Al) Current Trip 50kA List Price, 65kA List Price, 100kA List Price, List Price, Sensor Function Product Number GO-15PM Product Number GO-15PM Product Number GO-15PM Product Number GO-15S Wire Range LIT SKHB6CA0800 $ SKLB6CA0800 $ SKPB6CA0800 $ LSIT SKHB6CB0800 $ SKLB6CB0800 $ SKPB6CB0800 $ () /0-500 Cu LIGT 2 SKHB6CC0800 $ SKLB6CC0800 $ SKPB6CC0800 $ TCAL81 $47.00 () /0-500 Al LSIGT 2 SKHB6CD0800 $86.00 SKLB6CD0800 $ SKPB6CD0800 $ LIT SKHB6CA1200 $ SKLB6CA1200 $ SKPB6CA1200 $ LSIT SKHB6CB1200 $ SKLB6CB1200 $ SKPB6CB1200 $ (4) Cu LIGT 2 SKHB6CC1200 $ SKLB6CC1200 $ SKPB6CC1200 $ TCAL125 $76.00 (4) Al LSIGT 2 SKHB6CD1200 $ SKLB6CD1200 $ SKPB6CD1200 $ MicroVersaTrip PM, 100% UL Rated (No Protective Relays) SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 Terminal Lugs for Front connection (Cu/Al) Current Trip 50kA List Price, 65kA List Price, 100kA List Price, List Price, Sensor Function Product Number GO-15PM Product Number GO-15PM Product Number GO-15PM Product Number GO-15S Wire Range LIT SKHH6CA0800 $ SKLL6CA0800 $ SKPP6CA0800 $ LSIT SKHH6CB0800 $ SKLL6CB0800 $ SKPP6CB0800 $ () /0-500 Cu LIGT 2 SKHH6CC0800 $ SKLL6CC0800 $ SKPP6CC0800 $ TCAL81 $47.00 () /0-500 Al LSIGT 2 SKHH6CD0800 $ SKLL6CD0800 $ SKPP6CD0800 $ LIT SKHH6CA1000 $ SKLL6CA1000 $ SKPP6CA1000 $ LSIT SKHH6CB1000 $ SKLL6CB1000 $ SKPP6CB1000 $ LIGT 2 SKHH6CC1000 $ SKLL6CC1000 $ SKPP6CC1000 $ LSIGT 2 SKHH6CD1000 $ SKLL6CD1000 $ SKPP6CD1000 $ TCAL125 $76.00 (4) Cu 4 LIT SKHH6CA1200 $ SKLL6CA1200 $ SKPP6CA1200 $ (4) Al LSIT SKHH6CB1200 $ SKLL6CB1200 $ SKPP6CB1200 $ LIGT 2 SKHH6CC1200 $ SKLL6CC1200 $ SKPP6CC1200 $ LSIGT 2 SKHH6CD1200 $ SKLL6CD1200 $ SKPP6CD1200 $ MicroVersaTrip Plus and PM Rating Plug Selection All Plugs List Price, $ MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages -106 to For grounded neutral systems (1**/w or **4w) a neutral current sensor is required. Refer to page Suitable for 500 kcmil copper, 1200A max. rating. 4 For ground fault neutral current sensor, use 1200A rating % UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 168D1678 Sh2 for details. 6 Not suitable for use with 100% rated, 1000A breaker frame. GO-15S 00 SRPK800B SRPK800B SRPK800B SRPK800B600 SKHB, SKHH, SKLB, 700 SRPK800B700 SKLL, SKPB, SKPP 800 SRPK800B SRPK1200B SRPK1200B SRPK1200B SRPK1200B SRPK1200B Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -67

68 Industrial Circuit Breakers A Circuit Breakers Electronic Trip Spectra RMS SK1200 with MicroVersaTrip Plus and PM 1 MicroVersaTrip PM, Standard UL Rated (With Protective Relaying) SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 Terminal Lugs for Front connection (Cu/Al) Current Trip 50kA List Price, 65kA List Price, 100kA List Price, List Price, Sensor Function Product Number GO-15PM Product Number GO-15PM Product Number GO-15PM Product Number GO-15S Wire Range LIT SKHB6DA0800 $ SKLB6DA0800 $ SKPB6DA0800 $ LSIT SKHB6DB0800 $85.00 SKLB6DB0800 $ SKPB6DB0800 $ () /0-500 Cu LIGT 2 SKHB6DC0800 $ SKLB6DC0800 $ SKPB6DC0800 $ TCAL81 $47.00 () /0-500 Al LSIGT 2 SKHB6DD0800 $ SKLB6DD0800 $ SKPB6DD0800 $ LIT SKHB6DA1200 $ SKLB6DA1200 $ SKPB6DA1200 $ LSIT SKHB6DB1200 $ SKLB6DB1200 $ SKPB6DB1200 $ (4) Cu LIGT 2 SKHB6DC1200 $ SKLB6DC1200 $ SKPB6DC1200 $ TCAL125 $76.00 (4) Al LSIGT 2 SKHB6DD1200 $ SKLB6DD1200 $ SKPB6DD1200 $ MicroVersaTrip PM, 100% UL Rated (With Protective Relays) SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only) Frame Vac, UL 489 Vac, UL 489 Vac, UL 489 Terminal Lugs for Front connection (Cu/Al) Current Trip 50kA List Price, 65kA List Price, 100kA List Price, List Price, Sensor Function Product Number GO-15PM Product Number GO-15PM Product Number GO-15PM Product Number GO-15S Wire Range LIT SKHH6DA0800 $ SKLL6DA0800 $ SKPP6DA0800 $ LSIT SKHH6DB0800 $ SKLL6DB0800 $ SKPP6DB0800 $ () /0-500 Cu LIGT 2 SKHH6DC0800 $ SKLL6DC0800 $ SKPP6DC0800 $ TCAL81 $47.00 () /0-500 Al LSIGT 2 SKHH6DD0800 $ SKLL6DD0800 $ SKPP6DD0800 $ LIT SKHH6DA1000 $ SKLL6DA1000 $ SKPP6DA1000 $ LSIT SKHH6DB1000 $ SKLL6DB1000 $ SKPP6DB1000 $ LIGT 2 SKHH6DC1000 $ SKLL6DC1000 $ SKPP6DC1000 $ LSIGT 2 SKHH6DD1000 $ SKLL6DD1000 $ SKPP6DD1000 $ TCAL125 $76.00 (4) Cu LIT SKHH6DA1200 $ SKLL6DA1200 $ SKPP6DA1200 $ (4) Al LSIT SKHH6DB1200 $ SKLL6DB1200 $ SKPP6DB1200 $ LIGT 2 SKHH6DC1200 $ SKLL6DC1200 $ SKPP6DC1200 $ LSIGT 2 SKHH6DD1200 $ SKLL6DD1200 $ SKPP6DD1200 $ MicroVersaTrip Plus and PM Rating Plug Selection All Plugs List Price, $ GO-15S 00 SRPK800B SRPK800B SRPK800B SRPK800B600 SKHB, SKHH, SKLB, 700 SRPK800B700 SKLL, SKPB, SKPP 800 SRPK800B SRPK1200B SRPK1200B SRPK1200B SRPK1200B SRPK1200B MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages -106 to For grounded neutral systems (1**/w or **4w) a neutral current sensor is required. Refer to page Suitable for 500 kcmil copper, 1200A max. rating. 4 For ground fault neutral current sensor, use 1200A rating % UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 168D1678 Sh2 for details. 6 Not suitable for use with 100% rated, 1000A breaker frame. -68 BuyLog Catalog Rev. 12/04 distributed by AA Electric

69 Industrial Circuit Breakers A Circuit Breakers Thermal-Magnetic Trip K1200 Line Circuit Breakers Types TKM, THMK Types TKM, THKM Interchangeable Trip, not suitable for reverse feed Complete Circuit Breaker Terminal Lugs for Front Includes Line and Load Lugs Connection (Cu/Al) 1 GO-15B Adjustable Instantaneous Trip Unit Only. Use Product Number Ampere Trip Ampere Range Standard List Hi-Break 1 List Frame Only List with Standard and List (Order 2 List Rating Low High Product Number Price Product Number Price Product Number Price Hi-Break Frames Price per pole) Price Wire Size 800A Frame Two-Pole TKMA82600WL $ THKMA82600WL $ TKMA86T00 $ TKMA82650WL $ THKMA82650WL $ TKM826F000 $ TKMA86T50 $ TKMA826400WL $ THKMA826400WL $ Standard TKMA86T400 $ TCAL61 $40.00 (2) 2/ TKMA826450WL $ THKMA826450WL $ Frame TKMA86T450 $ Cu/Al TKMA826500WL $ THKMA826500WL $ TKMA86T500 $ TKMA826600WL $ THKMA826600WL $ TKMA86T600 $ TKMA826700WL $ THKMA826700WL $ THKM826F000 TKMA86T700 $ TCAL81 $ () / TKMA826800WL $ THKMA826800WL $ Hi-Break Frame $ TKMA86T800 $ Cu/Al 800A Frame Three-Pole TKMA8600WL $ THKMA8600WL $ TKMA86T00 $ TKMA8650WL $ THKMA8650WL $ TKM86F000 $ TKMA86T50 $ TKMA86400WL $ THKMA86400WL $ Standard TKMA86T400 $ TCAL61 $40.00 (2) 2/ TKMA86450WL $ THKMA86450WL $ Frame TKMA86T450 $ Cu/Al TKMA86500WL $ THKMA86500WL $ TKMA86T500 $ TKMA86600WL $ THKMA86600WL $ TKMA86T600 $ TKMA86700WL $ THKMA86700WL $ TKMA86T700 $ TKMA86800WL $ THKMA86800WL $ TKMA86T800 $ TCAL81 $ () / THKM86F000 Cu/Al Mag Hi-Break Frame $ TKMA86TM48 $ Only TKMA86TM68 $ For optional lugs, see page Not UL listed. Internal accessory installation requires dummy trip unit. See page -91 for additional details. Nonautomatic trip unit and dummy trip unit not UL listed for field installation. 4 GO-15S. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -69

70 Molded Case Circuit Breakers Industrial Circuit Breakers A Circuit Breakers Thermal-Magnetic Trip K1200 Line Circuit Breakers Types TKM, THMK Types TKM, THKM Interchangeable Trip, not suitable for reverse feed Complete Circuit Breaker Terminal Lugs for Front Includes Line and Load Lugs Connection (Cu/Al) 1 GO-15B Adjustable Instantaneous Trip Unit Only. Use Product Number Ampere Trip Ampere Range Standard List Hi-Break 1 List Frame Only List with Standard and List (Order 2 List Rating Low High Product Number Price Product Number Price Product Number Price Hi-Break Frames Price per pole) Price Wire Size 1200A Frame Two-Pole TKMA20600WL $ THKMA20600WL $ TKM2F TKMAT0600 $ TCAL81 $ () / TKMA20700WL $ THKMA20700WL $ Standard $ TKMAT0700 $ Cu/Al TKMA20800WL $ THKMA20800WL $ Frame TKMAT0800 $ TKMA21000WL $ THKMA21000WL $65.00 TKMAT $ (4) TKMA21200WL $ THKMA21200WL $ TKMAT $ TCAL121 $ Cu or THKM2F $ (4) Hi-Break Frame Al 1200A Frame Three-Pole 500 TKMAT TKMA0600WL $ THKMA0600WL $ TKMAT0600 $ TCAL81 $ () / TKMA0700WL $ THKMA0700WL $ TKMAT0700 $ Cu/Al TKMA0800WL $ THKMA0800WL $ TKMF $09.00 TKMAT0800 $ TKMA1000WL 4 $ THKMA1000WL 4 $ Standard TKMAT $ TKMA1200WL 4 $ THKMA1200WL 4 $ Frame TKMAT $ (4) Mag THKM2F $ TKMATM512 $ TCAL121 $ Cu or Only Hi-Break Frame TKMATM612 $ (4) Al 1 For optional lugs, see page GO-15S. Not UL listed. 4 Not Suitable for use on dc systems. 5 Suitable for 500 kcmil Cu for voltage drop considerations. Accessories: See pages -85 to BuyLog Catalog Rev. 12/04 distributed by AA Electric

71 Industrial Circuit Breakers A Circuit Breakers Electronic Trip R Frame Circuit Breaker Frames R-Frame Molded Case Circuit Breaker Frames 600 Vac, 50/60 Hz, -Poles only. Suitable for Reverse Feed Complete breaker requires frame and rating plug. For 4-wire GF application, select neutral CT from page -105, order separately. IC Ratings shown are at 480 Vac. Circuit Breaker Frame Selection MicroVersaTrip Plus Trip Units Standard Rating 100% Rating GO-15S Current Trip 65kAIC 65kAIC Sensor Function Product Number List Price Product Number List Price LIT TRLA6BA10 $ TRLL6BA10 $ LSIT TRLA6BB10 $ TRLL6BB10 $ LIGT TRLA6BC10 $ TRLL6BC10 $ A LSIGT TRLA6BD10 $ TRLL6BD10 $ LIGTZ1 TRLA6BE10 $ TRLL6BE10 $ LSIGTZ1 TRLA6BF10 $ TRLL6BF10 $ LSIGTZ2 TRLA6BG10 $ TRLL6BG10 $ LIT TRLA6BA16 $ TRLL6BA16 $ LSIT TRLA6BB16 $ TRLL6BB16 $ LIGT TRLA6BC16 $ TRLL6BC16 $ A LSIGT TRLA6BD16 $ TRLL6BD16 $ LIGTZ1 TRLA6BE16 $ TRLL6BE16 $ LSIGTZ1 TRLA6BF16 $ TRLL6BF16 $ LSIGTZ2 TRLA6BG16 $ TRLL6BG16 $ LIT TRLA6BA20 $ TRLL6BA20 $ LSIT TRLA6BB20 $ TRLL6BB20 $ LIGT TRLA6BC20 $ TRLL6BC20 $ A LSIGT TRLA6BD20 $ TRLL6BD20 $ LIGTZ1 TRLA6BE20 $ TRLL6BE20 $ LSIGTZ1 TRLA6BF20 $ TRLL6BF20 $ LSIGTZ2 TRLA6BG20 $ TRLL6BG20 $ Standard Rating 100% Rating Current Trip 100kAIC 100kAIC Sensor Function Product Number List Price Product Number List Price LIT TRPA6BA10 $ TRPP6BA10 $ LSIT TRPA6BB10 $ TRPP6BB10 $ LIGT TRPA6BC10 $ TRPP6BC10 $ A LSIGT TRPA6BD10 $ TRPP6BD10 $ LIGTZ1 TRPA6BE10 $ TRPP6BE10 $ LSIGTZ1 TRPA6BF10 $ TRPP6BF10 $ LSIGTZ2 TRPA6BG10 $ TRPP6BG10 $ LIT TRPA6BA16 $ TRPP6BA16 $ LSIT TRPA6BB16 $ TRPP6BB16 $ LIGT TRPA6BC16 $ TRPP6BC16 $ A LSIGT TRPA6BD16 $ TRPP6BD16 $ LIGTZ1 TRPA6BE16 $ TRPP6BE16 $ LSIGTZ1 TRPA6BF16 $ TRPP6BF16 $ LSIGTZ2 TRPA6BG16 $ TRPP6BG16 $ LIT TRPA6BA20 $ TRPP6BA20 $ LSIT TRPA6BB20 $ TRPP6BB20 $ LIGT TRPA6BC20 $ TRPP6BC20 $ A LSIGT TRPA6BD20 $ TRPP6BD20 $ LIGTZ1 TRPA6BE20 $ TRPP6BE20 $ LSIGTZ1 TRPA6BF20 $ TRPP6BF20 $ LSIGTZ2 TRPA6BG20 $ TRPP6BG20 $ R-Frame Current Sensors and Rating Plugs GO-245A Rating Plug Sensor Current Rating Product Number List Price 400 A TR10B400 $ A 600 A TR10B600 $ A TR10B800 $ A TR10B1000 $ A TR16B600 $ A TR16B800 $ A 1000 A TR16B1000 $ A TR16B1100 $ A TR16B1200 $ A TR16B1600 $ A TR20B750 $ A TR20B800 $ A TR20B1000 $ A 1200 A TR20B1200 $ A TR20B1500 $ A TR20B1600 $ A TR20B2000 $89.00 Rating Plug TRTOOL $ Removal Tool 1 GO-15S. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -71

72 Molded Case Switches A Spectra RMS Molded Case Switches UL File E-57546, CSA LR Includes fixed, high-set Instantaneous trip suitable for reverse feed. GO-15S Terminal Lugs for Maximum Sort Circuit Withstand Rating 2 Switch 1 Front Connection (Cu/Al) (ka rms symmetrical) Frame Ampere Type Rating Product Number List Price Product Number List Price Wire Range 240 Vac 480 Vac 600 Vac SE150 SF250 SG600 SK SEDA6AN0100 $ TCAL18 $.00 Aluminum: #12-/ SEDA6AN0150 $ Copper: #14-/0 250 SFDA6AN0250 $ TCAL29 $8.00 Aluminum: #8-50 kcmil Copper: #8-50 kcmil 400 SGDA6AN0400 $ pole lug kit Aluminum: (2) 2/0-500 kcmil SGDA6AN0600 $ TCLK65 $42.00 or (1) #6-600 kcmil Copper: (2) 2/0-500 kcmil or (1) #8-600 kcmil 800 SKDA6AN0800 $ TCAL81 $47.00 Aluminum: () /0-500 kcmil Copper: () /0-500 kcmil SKDA6AN1000 $ Aluminum: TCAL125 $76.00 (4) kcmil 1200 SKDA6AN1200 $ Copper: (4) kcmil 4 1 No rating plug required. 2 The maximum withstand rating is limited by the application to the value set forth in this table or the short circuit rating of the upstream fuse or circuit breaker, whichever is less. The upstream protective device must have an instantaneous trip function or element and its rated ampacity may not exceed the ampere rating of the switch. Order one kit for either line or load end; two kits required for both. 4 Suitable for 500 kcmil copper, 1200A max. rating. Noninterchangeable Trip, Includes Cu/Al load lugs. For optional lugs, see page -101 and GO-15B Type Ampere Rating Number of Poles Voltage Rating Product Number List Price TEB Vac, 125 Vdc TEB111Y100 5 $65.50 TEB Vac, 250 Vdc TEB122Y100 5 $ TEB Vac TEB12Y100 5 $ TED Vac, 125 Vdc TED11Y100 5 $82.50 TED Vac, 250 Vdc TED124Y100 5 $26.00 TED Vac, 250 Vdc TED124Y150 5,6 $ TFJ Vac TFJ226Y225 5,7 $80.00 TFJ Vac TFJ26Y225 $ TJJ Vac, 250 Vdc TJJ426Y400 8 $ TJJ Vac TJJ46Y400 8 $ Interchangeable Trip, Includes Cu/Al load lugs. For optional lugs, see page -101 and GO-15B Type Ampere Rating Number of Poles Voltage Rating Product Number List Price TFK Vac, 250 Vdc TFK226Y225 7,8,9 $97.00 TFK Vac, 250 Vdc TFK26Y225 8,9 $ TJK Vac, 250 Vdc TJK426Y400 8 $ TJK Vac, 250 Vdc TJK46Y400 8 $20.00 TJK Vac, 250 Vdc TJK626Y600 8 $ TJK Vac, 250 Vdc TJK66Y600 8 $ TMK Vac, 250 Vdc TMKA86Y800 8 $ TMK Vac, 250 Vdc TMKA826Y800 8 $ TMK Vac, 250 Vdc TMKA2Y $11.00 TMK Vac, 250 Vdc TMKAY $ TMK Vac, 250 Vdc TMKA2Y $ TMK Vac, 250 Vdc TMKAY $ Internal accessory requires factory installed dummy trip. Specify on order. Accessories not available for one-pole TEB, TED. 6 Not UL listed Volts max. 8 Internal accessory requires factory installed dummy trip unit. See page -91 for additional details. Nonautomatic trip unit and dummy trip not UL listed for field installation. 9 UL listed only when ordered as a complete switch. -72 BuyLog Catalog Rev. 12/04 distributed by AA Electric

73 Motor Circuit Protectors -1200A Spectra RMS Spectra RMS Mag-Break Motor Circuit Protectors Current Limiting, UL Component Recognized 1 Features Suitable for Reverse Feed UL Recognized File E CSA Certified LR 4050 IEC Vac Max. SE Ampere Max. SF Ampere Max. SG Ampere Max. SK Ampere Max. UL Current Limiting High Interrupting Capacity Spectra RMS Motor Circuit Protectors Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Vac Vac Adjustable Instantaneous Ampere Trip Ampere Range Product List Price, Current Product List Price, Product List Price, Product List Price, Wire Rating Low High Number GO-15S Sensor Number GO-141S Number GO-141S Number GO-15S Range SE150 Line -Pole 11 9 SRPE7A $ SRPE7A7 $ SELA6AI0007 $50.00 SEPA6AI0007 $66.00 TCAL18 $ SRPE0A15 $ SRPE0A20 $ SRPE0A25 $ SELA6AI000 $50.00 SEPA6AI000 $66.00 TCAL18 $ SRPE0A0 $ /0 Cu SRPE60A40 $ SRPE60A50 $ SELA6AI0060 $ SEPA6AI0060 $ TCAL18 $ SRPE60A60 $ /0 Al SRPE100A70 $ SRPE100A80 $ SRPE100A90 $ SELA6AI0100 $ SEPA6AI0100 $94.00 TCAL18 $ SRPE100A100 $ SRPE150A110 $ SRPE150A125 $ SELA6AI0150 $ SEPA6AI0150 $ TCAL18 $ SRPE150A150 $ Standard Capacity Mag-Break Motor Circuit Protectors Adjustable Magnetic Trip, Noninterchangeable Types TEC, TECL Complete Breaker (includes line and load lugs) GO-141 Adjustable Trip Add-on Limiter Three-Pole, Ampere Ampere Range 2 Two-Pole, 480 Vac Three-Pole, 600 Vac 100 kaic Rating Low High Product Number List Price Product Number List Price Product Number List Price 8 8 TEC2400 $18.00 TEC600 $88.00 TECL600 $ TEC24007 $18.00 TEC6007 $88.00 TECL6007 $ TEC24015 $18.00 TEC6015 $88.00 TECL6015 $ TEC2400 $18.00 TEC600 $88.00 TECL600 $ TEC24050 $77.00 TEC6050 $ TECL6050 $ TEC24100 $41.00 TEC6100 $ TECL6100 $ TEC24150 $ TEC6150 $ TECL6150 $ Per UL 489, interrupting capacities are not shown on product label. 2 AC only Two-pole furnished in three-pole case. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -7

74 Motor Circuit Protectors A Spectra RMS Spectra RMS Mag-Break Motor Circuit Protectors Current Limiting, UL Component Recognized 1 SF250 Line -Pole Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Adjustable Instantaneous Vac Vac Ampere Trip Ampere Range Product List Price, Current Product List Price, Product List Price, Product List Price, Wire Rating Low High Number GO-15S Sensor Number GO-141S Number GO-141S Number GO-15S Range SE150 Line -Pole SRPF250A70 $ SRPF250A90 $ SRPF250A100 $ SRPF250A110 $ SRPF250A125 $ SFLA6AI0250 $ SFPA6AI0250 $ TCAL29 $ Cu SRPF250A150 $ Al SRPF250A175 $ SRPF250A200 $ SRPF250A225 $ SRPF250A250 $ Types TFC, TJC, TKC -Pole Adjustable Instantaneous Trip Ampere Range GO-15B Complete Breaker (includes line and load lugs) Ampere Rating Low High Product Number List Price TFC6225 $ TFC6225A $ TJC6400E $ TJC6400F $ TJC6400G $ TJC6400B $ TJC6600G $ TJC6600H $ TKC6800L 2 $ TKC6800M 2 $ TKC61200L 2 $ TKC61200M 2 $ Type TBC with Current Limiters Complete Breaker (includes line and load lugs) Adjustable Instantaneous Standard Replacement Trip Ampere Range Three-Pole Current Limiters GO-15B Ampere Rating Low High Product Number List Price Product Number List Price TBC4225F14F $ TB10F14 $ TBC4400F14G $ TB10F14 $ TBC6600J14L $ TB10BJ14 $ TBC8800K22 2 $ TB15K22 $ Per UL 489, interrupting capacities are not shown on product label. 2 Balanced three-phase inrush current will trip the circuit breaker at lower than indicated currents. For motors over 50 hp, use Spectra RMS SK frame or circuit breakers with MicroVersaTrip Plus Trip Units Accessories: See pages -8 to BuyLog Catalog Rev. 12/04 distributed by AA Electric

75 Motor Circuit Protectors A Spectra RMS Spectra RMS Mag-Break Motor Circuit Protectors Current Limiting, UL Component Recognized 1 SG 600 Line -Pole Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Adjustable Instantaneous Vac Vac Ampere Trip Ampere Range Product List Price, Current Product List Price, Product List Price, Product List Price, Wire Rating Low High Number GO-15S Sensor Number GO-141S Number GO-141S Number GO-15S Range 400 Ampere Max SRPG400A125 $ SRPG400A150 $ Pole (2) 2/0-500 Cu SRPG400A175 $ lug kit or SRPG400A200 $ (1) Cu SRPG400A225 $ SGLA6AI0400 $ SGPA6AI0400 $ TCLK65 2 $ SRPG400A250 $ SRPG400A00 $ (2) 2/0-500 Al SRPG400A50 $ or SRPG400A400 $ (1) Al 600 Ampere Max SRPG600A250 $ SRPG600A00 $ Pole (2) 2/0-500 Cu SRPG600A50 $ lug kit or (1) Cu SRPG600A400 $ SRPG600A450 $ SGLA6AI0600 $ SGPA6AI0600 $ TCLK65 2 $42.00 (2) 2/0-500 Al SRPG600A500 $ or (1) Al SRPG600A600 $ SK1200 Line (Not Current Limiting) -Pole Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Adjustable Instantaneous Vac Ampere Trip Ampere Range Product List Price, Current Product List Price, Product List Price, Wire Rating Low High Number GO-15S Sensor Number GO-141S Number GO-15S Range 800 Ampere Max SRPK800A00 $ SRPK800A400 $ () /0-500 Cu SRPK800A500 $ SKLA6AI0800 $ TCAL81 $ SRPK800A600 $ SRPK800A700 $ () /0-500 Al SRPK800A800 $ Ampere Max SRPK1200A600 $ SRPK1200A700 $ (4) Cu SRPK1200A800 $ SKLA6AI1200 $ TCAL125 $ SRPK1200A1000 $ (4) Al SRPK1200A1200 $ Per UL 489, interrupting capacities are not shown on product label. 2 Order one kit for either the line or load end; two kits required for both. Suitable for 500 kcmil copper, 1200A max. rating. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -75

76 Special Purpose Mine Duty Breakers Mine Duty Circuit Breakers Standard Duty amperes 600 Vac 00 Vdc Three-Pole 1000 Wye 577 Vac (Not UL Listed) Without Line or Load Lugs 1 Complete Breaker Frame Only Trip Unit Only Thermal Magnetic Magnetic Only Thermal Magnetic Magnetic Only GO-15A Ampere Magnetic Instantaneous Trip Product Product Product Product Product Rating Low High Number List Price Number List Price Number List Price Number List Price Number List Price E Frame 100 Amperes Maximum, Noninterchangeable Trip TE11050MD $ TE11M050MD $ TE11100MD $ TE11M100MD $ J Frame 225 Amperes Maximum, Interchangeable Trip TJ12225MD1 TJ12M2MD1 TJ12FMD $21.00 TJ2225TMD1 $ TJ2M2TMD1 $ TJ12225MD2 TJ12M2MD2 TJ2225TMD2 $ TJ2M2TMD2 $ J Frame 400 Amperes Maximum, Interchangeable Trip TJ14400MD2 TJ14M4MD2 TJ14FMD $ TJ4400TMD2 $ TJ4M4TMD2 $ TJ14400MD TJ14M4MD TJ4400TMD $ TJ4M4TMD $ J Frame 600 Amperes Maximum, Interchangeable Trip TJ16600MD TJ16M6MD TJ16FMD $ TJ6600TMD $ TJ6M6TMD $ K Frame 800 Amperes Maximum, Interchangeable Trip TK18600MD TK800TMD $ TK18400MD4 TK8400TMD4 $ TK18600MD4 TK18FMD $ TK8600TMD4 $ TK18600MD5 TK8600TMD5 $ TK18800MD4 TK1M8MD4 TK8800TMD4 $ TK8M8TMD4 $ TK18800MD5 TK1M8MD5 TK8800TMD5 $ TK8M8TMD5 $ K Frame 1200 Amperes Maximum, Interchangeable Trip, TK1A10MD5 TK1AFMD $ TKA10TMD5 $ TK1A12MD5 TK1M12MD5 TKA12TMD5 $ TKM12TMD5 $ The lugs recommended for use with all Mine Duty breakers are copper for use with copper cable. Select from page Applies only to magnetic-only breakers. Order frame plus trip unit; not available as complete breaker. 4 Not suitable for use on dc. Accessories: See pages -85 to BuyLog Catalog Rev. 12/04 distributed by AA Electric

77 Replacement Breakers TriBreak Internally Fused TB1 TB4 TB6 TB1, 150A Frame, Noninterchangeable Trip (Includes line and load lugs) GO-15B Tri-Break Including Lugs 2 Replacement Current Limiters 1 Current Limiters 1 Adjustable Instantaneous Three-Pole Product No. Trip Units Standard Optional 1 Ampere Trip Amperes Range Product List and Wire Sizes List Product List Product List Product List Rating Low High Number Price (order 2 per pole) Price Number Price Number Price Number Price 15 Fixed TB1015BWE05 $ Fixed TB1020BWE05 $ TCAL14 25 Fixed TB1025BWE05 $ #14-8 Lugs 0 Fixed TB100BWE05 $ Cu-Al Furnished 5 Fixed TB105BWE05 $ with TCAL Fixed TB1040BWE05 $ Breaker #14-2/0 45 Fixed TB1045BWE05 $ Cu-Al 50 Fixed TB1050BWE09 $ Fixed TB1060BWE09 $ Fixed TB1070BWE09 $ Lugs 80 Fixed TB1080BWE09 $ TCAL 12 Furnished 90 Fixed TB1090BWE09 $ #14-2/0 with 100 Fixed TB1100BWE09 $ Cu-Al Breaker 100NA TB1BYWE09 5,6 $ TB4E05 $ Not Available TB7E09 $ TB4E05 $ TB4, 400A Frame, Interchangeable Trip (Without line or load lugs) GO-15B Tri-Break Including Lugs 2 Replacement Current Limiters 1 Current Limiters 1 Adjustable Instantaneous Three-Pole Product No. Trip Units Standard Optional 1 Ampere Trip Amperes Range Product List and Wire Sizes List Product List Product List Product List Rating Low High Number Price (order 2 per pole) Price Number Price Number Price Number Price TB4125AF14 $ TB4T125 $ TB4150AF14 $ $14.00 TB4T150 $ TB4175AF14 $ TB4T175 $47.00 TCAL TB4200AF14 $ TCAL4 TB4T200 $47.00 TBF05 $ (1) kcmil TB4225AF14 $ (1) kcmil $14.00 TB4T225 $47.00 TB10F14 $77.00 or or TB4250AF14 $ or TB4T250 $ TB6F09 $77.00 (2) 2/0-250 kcmil TB400AF14 $ (2) 2/0-250 kcmil TB4T00 $ TB450AF14 $ TB4T50 $ TB4400AF14 $ TB4T400 $ NA TB4AYW F14 5,6 $ Standard current limiters (bolt on: TB1, TB6, TB8 and plug-in: TB4) have been selected based upon recommended coordination with thermal magnetic trip characteristics of the breaker. Optional current limiters are not UL listed in combination with breaker except TB4 with TBF05 or TB6F09, 250A maximum. 2 For optional lugs, see page Trip units fit 2 and pole frames. 4 GO-148D. 5 Molded case switch. Includes dummy trip, line and load lugs. 6 Not UL listed. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -77

78 Replacement Breakers TriBreak Internally Fused TB6, 600A Frame, Interchangeable Trip (Without line or load lugs) GO-15B Tri-Break Including Lugs 2 Replacement Current Limiters 1 Current Limiters 1 Adjustable Instantaneous Three-Pole Product No. Trip Units Standard Optional 1 Ampere Trip Amperes Range Product List and Wire Sizes List Product List Product List Product List Rating Low High Number Price (order 2 per pole) Price Number Price Number Price Number Price TB600BJ14 $ TB6T00 $ TB650BJ14 $ TCAL61 TB6T50 $24.00 TBBJ05 $ TCAL TB6400BJ14 $ (2) 2/0-500 $40.00 TB6T400 $24.00 TB10BJ14 $54.00 or (2) 2/0-500 kcmil TB6500BJ14 $ kcmil TB6T500 $24.00 TB6BJ09 $ TB6600BJ14 $ TB6T600 $ NA TB6BYWJ14 4 $ TB8, 800A Frame, Interchangeable Trip (Without line or load lugs) GO-15B Tri-Break Including Lugs 2 Replacement Current Limiters 1 Current Limiters 1 Adjustable Instantaneous Three-Pole Product No. Trip Units Standard Optional 1 Ampere Trip Amperes Range Product List and Wire Sizes List Product List Product List Product List Rating Low High Number Price (order 2 per pole) Price Number Price Number Price Number Price TB8600BK22 $ TB8T600 $24.00 TB6BJ09 5 $54.00 TCAL TB8700BK22 $ $47.00 TB8T700 $24.00 TB15K or () kcmil TB8800BK22 $ TB8T800 $24.00 TB10BJ14 5 $ NA TB8AYWK22 4,5 $ Old Style (Plug-in) Replacement Limiters Breaker Ampere Replacement Limiter 1 Type Range Standard Optional 1 TB TBE05 TB TB6E09 TBE05 TB TB7E10 TB7E09 TB TB10J14 TBJ05 TB6J09 TB TB15K Standard current limiters (bolt on: TB1, TB6, TB8 and plug-in: TB4) have been selected based upon recommended coordination with thermal magnetic trip characteristics of the breaker. Optional current limiters are not UL listed in combination with breaker except TB4 with TBF05 or TB6F09, 250A maximum. 2 For optional lugs, see page Trip units fit 2 and pole frames. 4 Molded case switch. Includes dummy trip, line and load lugs. 5 Not UL listed. 6 GO-15S. -78 BuyLog Catalog Rev. 12/04 distributed by AA Electric

79 Replacement Breakers THLC Current Limiting Unfused Amperes 240 Vac max. Vac max. Vac max. THLC1, 150A Frame, Amperes, Noninterchangeable Trip with Line and Load Lugs GO-15B Ampere Rating -Pole Product Number List Price 15 THLC16015WL $ THLC16020WL $ THLC1600WL $ THLC16040WL $ THLC16050WL $ THLC16060WL $ THLC16070WL $ THLC16080WL $ THLC16090WL $ THLC160100WL $ THLC160125WL $ THLC160150WL $ Internal accessories for THLC1 are same as Type TED accessories. Refer to pages -86 to -91. THLC1 THLC2, 225A Frame, Amperes, Noninterchangeable Trip with Line and Load Lugs Adjustable Trip Range Amperes GO-15B Ampere Rating Low High -Pole Product Number List Price THLC26125WL $ THLC26150WL $ THLC26175WL $ THLC26200WL $ THLC26225WL $ Internal accessories for THLC2 and THLC4 are same as Type TFK accessories. Refer to pages -87 to -91. Accessory must have code date 55+ or later. THLC4, 400A Frame, Amperes, Noninterchangeable Trip without Line and Load Lugs 1 Adjustable Trip Range Amperes GO-15B Ampere Rating Low High -Pole Product Number List Price THLC46250 $ THLC4600 $ THLC4650 $ THLC46400 $ Lug kit for THLC4 for line or load end. Order Product Number TCLK4, List Price $49.00, GO-15B. Consists of three-pole assembly. Wire range (1) /0-500 or (2) /0-250 Cu-Al. THLC2 THLC4 Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -79

80 Replacement Breakers J and K Frame Circuit Breakers with MicroVersaTrip Plus Trip Units For Replacement Use Only For New Breaker Designs, use Spectra RMS Breakers with MicroVersaTrip Plus How To Order Determine the required breaker frame (i.e. 600 or 1200 amperes), IC rating, and load requirements (UL Standard or 100%). Select frame product number and list price from table below. Select and price the appropriate trip unit from table below. Select and price the required rating plug from table below. The sensor rating of frame must match the sensor rating of the rating plug in table. Select and price lugs and lug covers as required from pages -101 and When ordering, specify separate product numbers as follows. The trip unit will be installed in the frame. Rating plugs and lugs/lug covers will be shipped unassembled. Frame Trip Unit Rating plug Lugs/Lug covers Other accessories (assembled or separate items) Pricing Example J600 frame, 00 ampere sensor, 250 ampere rating plug, 5kAIC, 480 Vac, IC 100% rated, trip unit functions to include long-time (L), short-time (S), instantaneous (I), ground fault (G), trip targets (T2), ground fault/short-time zone selective interlocking (Z2), -phase/-wire system. Product List Price, Description Number GO-15D Frame TJHSS $ Trip Unit and Suffix Adder TS20LSIGT2Z2 $ Rating Plug TRS250J $ Zone Interlock Module (120 Vac) TIM1 $ Neutral Current Sensor TSRG20 $ Lugs 1 GO-245B. 2 GO-15S. MicroVersaTrip Plus Trip Unit Characteristics Current Setting (Multiple of rating plug ampere) (X) 1.0,.95,.90,.85,.80,.70,.60,.50 Long-Time 2 Delay (Seconds) 2.4, 4.9, 9.8, 20 at 600% of current setting at lower limit of each band Pick-Up (Multiple of Current Setting) (C) 1.5, 2.0, 2.5,.0, 4.0, 6.0, 7.0, 9.0 Short-Time Delay (Seconds) I 2 t in;.44 I 2 t out: 5.10,.21,.5 Adjustable Instantaneous Pick-Up (Multiple of Rating Plug Amperes) (X) 1.5, 2.0,.0, 5.0, 7.0, 9.0, 10.0 without short-time 1.5, 2.0,.0, 5.0, 7.0, 9.0, 10.0, 1.0, with short-time Pick-Up (Multiple of Sensor Ampere Rating) (S).20,.25,.0,.5,.40,.45,.50,.60 2 Pick-up fixed at 1.1C. Time delay at 600% of current setting at lower limit of band. 4 Time delay at 200% of pick-up setting at lower limit of band. 5 Time delay shown at lower limit of each band. Pick-up tolerances ±10%. Ground fault pick-up not to exceed 1200 amperes. 6 J600 frame with 600 amp sensor for high IC 65kA rating (TJL) limited to 10X X = rating plug amperes. S = sensor ampere rating C = current setting Ground Fault Delay (Seconds) I 2 t in; 4.44 I 2 t out: 5.10,.21,.5 Circuit Breaker Frame Selection (less lugs) GO-15D Frame Sensor Rating 65 kaic List 100% 65 kaic List Hi-Break List 100% Hi-Break 7 List Type (Amperes) Product Number Price Product Number Price Product Number Price Product Number Price J600 K TJL1S $ TJL1SS $ TJH1S $ TJH1SS $ TJLS $ TJLSS $ TJHS $ TJHSS $ TJL4S $ TJL4SS $ TJH4S $ TJH4SS $ TJL6S $ TJL6SS $ TJH6S $ TJH6SS $ TKL8S $ TKL8SS $ TKH8S $ TKH8SS $ TKL12S $ TKL12SS $ TKH12S $ TKH12SS $ % supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 19C45 Sh7 for details. -80 BuyLog Catalog Rev. 12/04 distributed by AA Electric

81 Replacement Breakers J and K Frame Circuit Breakers with MicroVersaTrip Trip Units For Replacement Use Only For New Breaker Designs, use Spectra RMS Breakers with MicroVersaTrip Plus J/K Rating Plug Selection All plugs List Price, $ GO-15D Frame Sensor Rating Current Rating Rating Plug Frame Sensor Rating Current Rating Rating Plug Type (Amperes) (Amperes) Product Number Type (Amperes) (Amperes) Product Number J TR1S60J 00 TR6S00J 80 TR1S80J 400 TR6S400J TR1S100J J TR6S450J 125 TR1S125J 500 TR6S500J 150 TR1S150J 600 TR6S600J 150 TRS150J 00 TR8S00K 200 TRS200J 400 TR8S400K TRS225J K TR8S500K 250 TRS250J 600 TR8S600K 00 TRS00J 700 TR8S700K 150 TR4S150J 800 TR8S800K 200 TR4S200J TR4S225J 600 TR12S600K 250 TR4S250J K TR12S800K 00 TR4S00J 1000 TR12S1000K 400 TR4S400J 1200 TR12S1200K Trip Unit Function Definitions Long-Time (L) Short-Time (S) Instantaneous (I) Ground Fault (G) Trip Indication Target (T1, T2) Zone Selective Interlock (Z1, Z2) Adjustable current setting Adjustable long-time delay Adjustable short-time pick-up Adjustable short-time delay with l 2 t Adjustable short-time delay without l 2 t Adjustable pick-up Adjustable ground fault pick-up Adjustable ground fault delay with l 2 t Adjustable ground fault delay without l 2 t Overload/short circuit targets (T1) Overload/short circuit/ground fault targets (T2) Ground fault (Z1) Ground fault/short-time (Z2) MicroVersaTrip Trip Unit Selection Targets GO-15D Zone Interlock Trip Unit List Long-Time Short-Time Instantaneous Ground Fault 1 OL, SC OL, SC, GF GF GF, ST Suffix Price (L) (S) (I) (G) (T1) (T2) (Z1) (Z2) TS20LIT1 $ TS20LSIT1 $ TS20LIGT2 $ TS20LSIGT2 $ TS20LIGT2Z1 $ TS20LSIGT2Z1 $40.00 TS20LSIGT2Z2 $ For single-phase, -wire or three-phase, 4-wire applications select appropriate neutral-current sensor from page -10. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -81

82 Replacement Breakers J and K Frame Circuit Breakers with Power+ 4 Trip Unit Part Number Selection Instructions 1. Select product number of circuit breaker, including trip unit suffix. 2. Select lugs, internal/external accessories and neutral current sensor, as required from pages -85 through Power+ Trip Unit Characteristics Frame Type Max. Amperes (X) Fixed Sensor Sensor Current Ratings (Amperes) J , , 400, 500, 600 K , 1000, 1200 Current Setting (Multiple of Sensor Current Rating) (X).5,.6,.7,.8,.9,.95, 1.0 (X) Pick-up (Multiple of Current Setting) (C).5,.6,.7,.8,.9,.9.5, 1.0 Long-Time Short-Time 1,2 Delay (Seconds), 6, 12, 25 Bands 1, 2,, 4 Pick-up (Multiple of Current Setting) (C) 1.5, 2, 2.5,, 4, 5, 7, 9 (C) I 2 t Delay Ramp (Seconds).1,.26,.42 (Min, Int, Max) Select trip unit product number from specific circuit breaker pages J and K frames, page -81. Adjustable Instantaneous Pick-Up 1 (Multiple of Sensor Current Rating (X) 1.5, 2,, 4, 5, 7, 9, 10 (X) Ground Fault 2 Pick-Up (Multiple of Sensor Current Rating) (X).2,.25,.,.5,.4,.45,.5,.6 (X) Delay 4 (Seconds) 0.10, (Min, Int, Max) 1 When optional adjustable short-time pick-up is provided, instantaneous is fixed at 15X. Short-time and fixed instantaneous are not available on TJL with 500A and 600A sensors. 2 Delay Curve = I 2 t in, I 2 t out Time delay shown at 600% of current setting at lower limit of each band. 4 Time delay shown at lower limit of each band. All pick-up tolerances are ± 10%. Ground Fault Pick-up not to exceed 1200 amperes. X = sensor current rating C = current setting Circuit Breaker Product Number Selection (less lugs) 5,6 Frame Type J600 K1200 Current Sensor Ampere Base Product No. Standard Circuit Breaker Hi-Break List Price, GO-148D with Suffix List Price, GO-148D with Suffix Base None N G NG Product No. None N G NG 150 TJ4V2601A $ $ $ $ THJ4V2601A $ $ $ $ TJ4V2602A $ $ $ $ THJ4V2602A $ $ $ $ TJ4V260A $ $ $ $ THJ4V260A $ $ $ $ TJ4V2604A $ $ $ $ THJ4V2604A $ $ $ $ TJ4V2605A $ $ $ $ THJ4V2605A $ $ $ $ TJ4V2606A $ $ $ $ THJ4V2606A $ $ $ $ TK4V4608A $ $ $ $ TK4V4610A $ $ $ $ TK4V4612A $ $ $ $ Circuit Breaker Product Number Selection (less lugs) 5,6 Frame Type J600 Current Sensor Ampere Base Product No. None N G NG 150 TJL4V2601A $ $ $ $ TJL4V2602A $ $ $ $ TJL4V260A $ $ $ $ TJL4V2604A $ $ $ $ TJL4V2605A 2 $ $ TJL4V2606A 2 $ kaic Breaker List Price, GO-148D with Suffix 7 $ Power+ 4 Trip Unit Selection Long-Time Short-Time Instantaneous Trip Unit Functions 800 TKL4V4608A $ $ $ $ Adj. Ground Fault Pick-Up Ground Fault 5 Zero Sequence K TKL4V4610A $ $ $ $ TKL4V4612A $ $ $ $ Adj. Ground Fault Delay 5 For single-phase, -wire or three phase, 4-wire applications, select 7 TJL4V with 500 and 600A sensors available with adjustable appropriate neutral-current sensor from page -10. instantaneous only. 6Select and price lugs and lug covers as required from pages -101 and = Function included. None Adjustable Current Setting Fixed Long-Time Pick-Up Fixed Long-Time Delay Long-Time Timing Light Adj. Short-Time Pick-Up Fixed Short-Time Delay I 2 t Ramp W Suffix G NG Adj. Instantaneous Pick-Up Fixed Instantaneous Pick-Up 7-82 BuyLog Catalog Rev. 12/04 distributed by AA Electric

83 Internal Accessories Spectra RMS Circuit Breakers Universal Field-Installable Internal Accessories All Spectra RMS circuit breakers from the SE150 through the SK1200, including instantaneous-trip Mag Break motor circuit protectors and molded case switches, use the same UL listed, field-installable internal accessories that do not require cover removal to install. Accessory Mounting All accessories mount in pouches accessible from a front cover. All breakers have a left-side pouch and right-side pouch. The following combinations may be installed: Left Side Pouch Left-Side Pouch either shunt trip or undervoltage release plus bell alarm. Right-Side Pouch auxiliary switch (single or double pole). Auxiliary Switch GO-15S Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT switch elements. Switch Number of Auxiliary Switch List Rating Switch Elements Product Number Price Vac/ 1 form C SAUXPAB1 $ Vdc 2 form C SAUXPAB2 $ Gold-Plated Contacts 1 form C SAUXGAB1 $ V 2 form C SAUXGAB2 $ One each 2 form C SAUXGPAB2 $ of above types Right Side Pouch Shunt Trip Red White Brown/white All accessory contacts shown with the circuit breaker in tripped position. GO-15S For remote tripping of breaker, use with momentary close contact. Not recommended for use with latching relay contact since electronics in shunt trip will pulse power to the coil if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2 seconds at rated control voltage. (A short-circuit trip would be instantaneous.) If maintained (latching relay) contact must be used and delayed shunt tripping is not acceptable, use small bell alarm in series with control power for SE150 and SF250 frames and auxiliary switch for SG600 and SK1200 breakers. These devices are suitable for use with ground fault sensing and relaying equipment. Maximum VA is 75. AC devices are UL listed for Hz. Auxilliary Switch Voltage Current (ma) Product List ac dc Inrush Cont Number Price SAST1 $ SAST2 $ SAST5 1 $ SAST $ SAST4 $ Not suitable for use with ground fault sensing and relaying equipment. Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories. Black Black All accessory contacts shown with the circuit breaker in tripped position. Shunt Trip Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -8

84 Internal Accessories Spectra RMS Circuit Breakers Undervoltage Release GO-15S The undervoltage release provides automatic circuit breaker tripping when there is a power loss or major dip (to 5%-70% of rated voltage) in accessory control voltage. AC devices are UL listed for Hz. Product number SAUV1 may be used with time delay unit SPUVTD (List Price $40.00, GO-245B) (delay 0.1 to 1.0 seconds), 120 Vac input, 125 Vdc output. Voltage Peak Current Product List ac dc (ma) Number Price SAUV1 $ SAUV2 $ SAUV $ SAUV4 $ SPUVTD $ GO-245B. Blue Blue All accessory contacts shown with the circuit breaker in tripped position. Undervoltage Release Bell Alarm Switch GO-15S The bell alarm switch provides remote indication of whether the circuit breaker has been tripped via open or closed SPDT switch elements, but remains unchanged during "On/Off" circuit breaker operation and during operation by the "Push-to-Trip" button. Switch Number of Product List Rating Switch Elements Number Price 240 Vac/ 125 Vdc 1 form C SABAP1 $ Gold-Plated Contacts 1 form C SABAG1 $ Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories. Purple Yellow Brown All accessory contacts shown with the circuit breaker in tripped position. Bell Alarm Switch -84 BuyLog Catalog Rev. 12/04 distributed by AA Electric

85 Internal Accessories Molded Case Circuit Breakers Accessory Devices and Ratings Internally mounted accessories can be either factory or field installed, but should be factory installed when UL listing is required. F225 frame accessories, including THLC2, and THLC4 are UL listed for field installation 1. Factory installed devices with leads exiting from the side are UL listed, but when leads exit from the back the UL listing is void. For accessory installation combinations refer to table below. Mounting Pole refers to left-, center- or right-hand pole as seen when facing the front of the breaker. Control leads may exit the breaker from its side (S) or back (B) 2. Nonautomatic circuit breakers (molded case switches) require dummy trip units if internal accessories are to be field installed (refer to page -91). Breaker Type Bell Alarm Switch Auxiliary Switch or Shunt Trip Undervoltage Release Inst. Sheet GEH- Mounting Pole Inst. Mounting Pole Inst. Mounting Pole Inst. Mounting Pole Sheet Sheet Sheet L C R GEH- L R GEH- L R GEH- L R J Frame Circuit Breaker with Internal Accessories Mounted in Each Pole Three Coil Shunt Trip Pole Positions L Left C Center R Right Lead Wire Exit S Side B Back Total Number of Accessories Within any One Circuit Breaker TQB, THQB, THHQB, TXQB, TQL, THQL, THHQL, TXQL, TQC, THQC, THHQC, TXQC 4 UL One accessory only. Mounts in a one-inch frame and increase overall breaker size by one pole. May be applied to 1-, 2-, or -pole breakers. TQD, THQD 4 UL One accessory only E150 TEB, TEC, TED, THED, THLC1, TB1 5,6,8 F225 9 TFC, TFJ, TFK, THFK, THLC2, THLC4, TLB2, TLB4 7 UL UL UL UL 418 Aux 416 S.T. UL UL 44 UL 4620 UL UL 465 UL UL UL UL 4622 any two J600 TJC, TJD, TJJ, TJK, THJK, 8 UL 20 UL UL TB4 5, TBC4 5 K1200 TKC, TKM, THKM TB6 5, TBC6 5, 8 UL 405 UL UL TB8, TBC8 TJ4V, TKL4V, TJH6S, TKL12S 8 solid-state trips Accessory-Lead Color Coding 10 UL 4626 UL Purple Yellow Brown Red White Brown/white Auxiliary Switch Black Black 21 Aux 45 S.T. 21 Aux 44 S.T. 462 Aux 462 S.T. UL UL 46 2-pole circuit breaker any one -pole circuit breaker any two except UVR and -coil shunt trip Any two plus belt alarm except TB4, TBC4 any one plus bell alarm. UL UL 46 Any two plus bell alarm UL 462 Any one plus bell alarm Blue Blue Red Brown/white Bell Alarm Switch Shunt Trip Undervoltage Release Three-Coil Shunt Trip 1 Except TFC and TFJ, F225 line model 4 frames and trips (mfg. code date J101+ (1981 or later), and THLC2, THLC4, TLB4 are UL listed for field installation of most accessories. 2 Not UL listed. 600 Vac auxiliary switches are not UL listed. 4 Accessories are factory installed only. 5 UL listed at 200 AIC without internal accessories, 100 AIC with internally mounted accessories. 6 Accessories not available for single-pole TEB/TED frame. Use two-pole circuit breaker. 7 Left pole mounting not available for two-pole TEB, TED. 8 Not available with lead exit from the back of breaker. 9 UL listed interrupting capacity with accessories: 10 kaic at 600 Vac, 22 kaic at 480 Vac, 22 kaic at 240 Vac. 10 Leads are # C Vulkene insulated. Blue White Yellow Black All accessory contacts shown with the circuit breaker in tripped position. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -85

86 Internal Accessories Internally Mounted Signaling and Controlling Functions How to Order For factory installation, specify breaker product number, accessory base number, and appropriate suffix. (Example: Product Number TJK46125WL, TJUV1RS, TJKASA2AB2LS specifies a type TJK breaker with factory installed undervoltage release in the right-hand pole and an auxiliary switch in the left-hand pole.) For field replacement, order the accessory by the base number only. Where this number ends in "R" or "L" right-hand and left-hand devices are physically different. Specify only one suffix letter per accessory product number when option is available. Nonautomatic circuit breakers require dummy trip units if internal accessories are to be mounted. Undervoltage Release Mine Duty Circuit Breaker Undervoltage Release GO-15A Factory Installed 1 Circuit Breaker Control Product Number List Field Replacement List Frame Voltage Premium Duty Price Product Number 2 Price E J K 24 Vac TEDMDVAS $ TEMDVAS $ Vac TEDMDVBS $ TEMDVBS $ Vac TEDMDVCS $ TEMDVCS $ Vdc TEDMDVDS $ TEMDVDS $ Vdc TEDMDVES $ TEMDVES $ Vdc TEDMDVFS $ TEMDVFS $ Vac TJMDVAS $ TJRMDVA $ Vac TJMDVBS $ TJRMDVB $ Vac TJMDVCS $ TJRMDVC $ Vdc TJMDVDS $ TJRMDVD $ Vdc TJMDVES $ TJRMDVE $ Vdc TJMDVFS $ TJRMDVF $ Vac TKMDVAS $ TKRMDVA $ Vac TKMDVBS $ TKRMDVB $ Vac TKMDVCS $ TKRMDVC $ Vdc TKMDVDS $ TKRMDVD $ Vdc TKMDVES $ TKRMDVE $ Vdc TKMDVFS $ TKRMDVF $ Mounts in right pole only. "S" suffix wires out the side of breaker. 2 Replacement for standard and premium duty mine duty UVR, both old and new design. -86 BuyLog Catalog Rev. 12/04 distributed by AA Electric

87 Internal Accessories Internally Mounted Signaling and Controlling Functions Auxiliary Switches Unless otherwise noted switch is SPDT rated 6 amperes at rated ac voltage, 1/2 amperes at 125 Vdc, 1/4 amperes at 250 Vdc. GO-15B Control Voltage 240 Vac, 250 Vdc Maximum Control Voltage 600 Vac, 250 Vdc Maximum UL Listed When Factory Installed Suffix 1 Not UL Listed Suffix 1 Number of Add to Base Product Add to Base Product SPDT Switch Base Number for Factory List Base Number for Factory List Breaker Type Elements Number Installation Price Number Installation Price TQB, THQB, THHQB, TXQB, TQL, 2 1 TQAS2A1 4 5 $64.50 THQL, THHQL, TXQL TQC, THQC, THHQC, TXQC 2 1 TQCAS2A1 4 5 $77.50 TQD, THQD 1 TQDAS2AB1RS N/A $ TEB, TEC, TB1 1 TEDAS2AB1R,L 7,8 S $ TEDAS6AB1R,L 7,8 S $ TED, THED,THLC1 8 2 TEDAS2AB2R,L 7,8 S $ TEDAS6AB2R,L 7,8 S $60.00 TFC, TFJ, TFK, THFK, 9 1 TFKASA2AB1 10 RS or LS $ TFKASA6AB1 10 RS $ THLC2, THLC4, TLB2, TLB4 2 TFKASA2AB2 10 RS or LS $ TFKASA6AB2 10 RS $ TJKASA2AB1R,L S $ TJKASA6AB1R,L S $ TJC, TJD, TJJ, TJK, THJK 2 TJKASA2AB2R,L S $ TJKASA6AB2R,L S $60.00 TJKASA2ABR,L S $49.00 TJKASA6ABR,L S $ TJKASA2AB4R,L S $ TJKASA6AB4R,L S $ TB4ASA2AB1R,L S $ TB4ASA6AB1R,L S $ TB4, TBC4 2 TB4ASA2AB2R,L S $ TB4ASA6AB2R,L S $60.00 TB4ASA2ABR,L S $49.00 TB4ASA6ABR,L S $ TB4ASA2AB4R,L S $ TB4ASA6AB4R,L S $ TKMAAS2AB1 RS or LS $ TKMAAS6AB1 RS or LS $ TKM, THKM, TKC, TB6, 2 TKMAAS2AB2 RS or LS $ TKMAAS6AB2 RS or LS $60.00 TB8, TBC6, TBC8 TKMAAS2AB RS or LS $49.00 TKMAAS6AB RS or LS $ TKMAAS2AB4 RS or LS $ TKMAAS6AB4 RS or LS $ TJ4V/TJL, TK4V/TKL 2 TVAS2AB2R 10 S $ TVAS6AB2R S $ TVAS2AB4R 10 S $ TVAS6AB4R S $ TPAS2AB1 10 S $ TPAS6AB1 S $ TPAS2AB2 10 S $ TPAS6AB2 S $ TPAS2AB 10 S $ TPAS6AB S $ TPAS2AB4 10 S $ TPAS6AB4 S $ TPAS2AB5 10 S $ TPAS6AB5 S $ TRL/TRP 6 TPAS2AB6 10 S $ TPAS6AB6 S $ R Frame 7 TPAS2AB7S 10 Must be Factory Installed $ TPAS6AB7S Must be Factory Installed $ TPAS2AB8S 10 Must be Factory Installed $ TPAS6AB8S Must be Factory Installed $ TPAS2AB9S 10 Must be Factory Installed $ TPAS6AB9S Must be Factory Installed $ TPAS2AB10S 10 Must be Factory Installed $ TPAS6AB10S Must be Factory Installed $ TPAS2AB11S 10 Must be Factory Installed $ TPAS6AB11S Must be Factory Installed $ TPAS2AB12S 10 Must be Factory Installed $ TPAS6AB12S Must be Factory Installed $ "S" suffix for wires out the side of breaker. For lead exit from back of breaker, replace suffix "S" with "B"" and multiply list price by "B" suffix not UL listed. Not available with leads out the back for "Q Line". 2 Not available on GFCI (5 ma) or Equipment Ground Fault (0 ma) breakers. Switch is SPST. Operates like "A" side of an "AB" contact and is rated six amperes at 120 Vac and three amperes at 24 Vac. 4 Accessories mounted in a one-inch frame and increase overall breaker size by one pole added to left side. May be applied to 1-, 2-, or -pole breakers. Must be factory installed. Maximum total breaker width is four poles. 5 To order, specify both the accessory and breaker product number, e.g. THQL210, TQASA1 identifies a 0 ampere, 2-pole plug-in breaker with a factory installed SPST auxiliary switch. 6 GO-15F. 7 Auxiliary switch mounts in right pole only on two-pole TEB, TED breakers. (Factory installed only.) 8 Not available with B suffix leads out back. 9 Changes circuit breaker interrupting capacity to 10kAIC, 600 Vac; 22 kaic, 240 and 480 Vac. 10 UL listed for field installation. 11 GO-15C. 12 GO-145A. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -87

88 Internal Accessories Internally Mounted Signaling and Controlling Functions How to Order For field replacement, order base number only. For factory installation, order base number plus appropriate suffix. For a nonautomatic breaker (molded case switch) a dummy trip is required when installing either a shunt trip or UVR. Shunt Trip Remote Tripping Trips breaker by remote control. Trip coil de-energized when breaker opens. Device meets UL requirements for service to ground fault system. Undervoltage Release Undervoltage release automatically trips breaker when applied coil voltage drops to 0 to 70 percent of rated value. Time-delay unit prevent nuisance tripping due to momentary loss of voltage. Separate externally mounted unit has 120 Vac input and 125 Vdc output. Used in conjunction with 125 Vdc undervoltage release which must be ordered separately. Product number SPUVTD for adjustable delay.1 to 1.0 seconds. List Price $40.00 GO-245B. Shunt Trip GO-15B Product Number 1,2 UL Listed When Factory Installed Suffix Number Accessory Voltage Base Number Add to Base Product Number List Breaker Type Vac Vdc for Field Replacement for Factory Installation Price TQSTA1 TQB, THQB, THHQB, TXQB, $ TQSTA7 TQL, THQL, THHQL, TXQL $ TQSTA8 4,6,7 10 $ TQDSTA 8,9 10 $ TQD, THQD 240 TQDSTA $ TQDSTA $ TQDSTA $ TEDST12 RS or LS 8,12 $ TEDST12 RS or LS 8,12 $ TEDST1 RS or LS 8,12 $6.00 TEB, TEC, TB1-B, TEDST1 RS or LS 8,12 $ TEDST7 RS or LS TED, THED, THLC1 $ TEDST8 RS or LS 8,12 $ TEDST9 RS or LS 8,12 $ TEDST12 RS or LS 8,12 $ TEDST11 RS or LS 8,12 $ TFKSTA12 1 RS or LS $ TFKSTA12 1 RS or LS $ TFKSTA1 1 RS or LS $ TFKSTA1 TFC, TFJ, TFK, THFK, THLC2, RS or LS $ TFKSTA7 THLC4, TLB2, TLB4 RS or LS $ TFKSTA8 1 RS or LS $ TFKSTA9 1 RS or LS $ TFKSTA12 1 RS or LS $ TFKSTA11 1 RS or LS $ UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4. 2 For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number 192A800G1. "S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by "B" suffix not UL listed. Not available with leads out the back on "Q Line." 4 Mounts on a one-inch frame and increases overall breaker size by one pole added to left side. May be applied to 1-, 2-, or -pole breakers. Maximum total breaker width is 4-pole. Must be factory installed. 5 A selective listing of breaker product numbers that include 120 Volt ac shunt trip appears on page Not available on GFCI (5 ma) or Equipment Ground Fault (0 ma) breakers. 7 TQST shunt trips not available on breakers over 100 A. 8 Not available with B suffix leads out back. 9 Must be factory installed, right pole only. 10 To order, specify both the accessory and breaker product number =, e.g.thql210, TQST1 identifies a 0 A, 2-pole plug-in breaker with a factory installed 120 Vac shunt trip. 11 For TB1 with bolt-on limiters. 12 Mounts in the right pole only on 2-pole TEB, TED breakers. -88 BuyLog Catalog Rev. 12/04 distributed by AA Electric

89 Internal Accessories Internally Mounted Signaling and Controlling Functions Shunt Trip (continued) GO-15B Product Number 1,2 UL Listed When Factory Installed Suffix Number Accessory Voltage Base Number Add to Base Product Number List Breaker Type Vac Vdc for Field Replacement for Factory Installation Price 120 TJKSTA12R,L S $ TJKSTA12R,L S $ TJKSTA1R,L S $ TJKSTA1R,L S $6.00 TJC, TJD, TJJ, TJK, THJK 12 TJKSTA7R,L S $ TJKSTA8R,L S $ TJKSTA9R,L S $ TJKSTA12R,L S $ TJKSTA11R,L S $ TB4STA12R,L S $ TB4STA12R,L S $ TB4STA1R,L S $ TB4STA1R,L S $6.00 TB4, TBC4 12 TB4STA7R,L S $ TB4STA8R,L S $ TB4STA9R,L S $ TB4STA12R,L S $ TB4STA11R,L S $ TKMASTA12R,L S $ TKMASTA12R,L S $ TKMASTA1R,L S $ TKMASTA1R,L S $6.00 TKC, TKM, THKM, TB6, 12 TKMASTA7R,L S $6.00 TB8, TBC6, TBC84 24 TKMASTA8R,L S $ TKMASTA9R,L S $ TKMASTA12R,L S $ TKMASTA11R,L S $ TVST12R S $ TVST12R S $ TVST1R S $ TVST1R S $6.00 TJ4V, TKL4V, 12 TVST7R S $6.00 TJH6S, TKL12S 24 TVST8R S $ TVST9R S $ TVST12R S $ TVST11R S $ TPST12R S $ TPST12R S $ TPST1R S $ TPST1R S $60.00 R Frame 12 TPST7R S $60.00 TRL, TRP 24 TPST8R S $ TPST9R S $ TPST12R S $ TPST11R S $ UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4. 2 For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number 192A800G1. "S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by "B" suffix not UL listed. Not available with leads out the back on "Q Line." 4 Not UL listed. 5 GO-15C UL listed for field installation. 6 GO-145A UL listed for field installation. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -89

90 Internal Accessories Internally Mounted Signaling and Controlling Functions UnderVoltage Release GO-15B Product Number 1,2 UL Listed When Factory Installed Suffix Number Accessory Voltage Base Number Add to Base Product Number List Breaker Type Vac Vdc for Field Replacement for Factory Installation Price 120 TEDUV1 RS 8 $ TEDUV2 RS 8 $ TEDUV4 RS 8 $6.00 TEB, TEC, TB1-B TEDUV6 RS 8 $ TEDUV7 RS TED, THED, THLC1 $ TEDUV8 RS 8 $ TEDUV9 RS 8 $ TEDUV10 RS 8 $ TEDUV11 RS 8 $ TFKUVA1 1 RS or LS $ TFKUVA2 RS or LS $ TFKUVA4 RS or LS $ TFKUVA6 RS or LS $6.00 TFC, TFJ, TFK, THFK, THLC2, 12 TFKUVA7 RS or LS $6.00 THLC4, TLB2, TLB4 24 TFKUVA8 RS or LS $ TFKUVA9 RS or LS $ TFKUVA10 RS or LS $ TDKUVA11 RS or LS $ TJUV1R S $ TJUV2R S $ TJUV4R S $ TJUV6R S $6.00 TJC, TJD, TJJ, TJK, THJK 12 TJUV7R S $ TJUV8R S $ TJUV9R S $ TJUV10R S $ TJUV11R S $ TKUV1R S $ TKUV2R S $ TKUV4R S $ TKUV6R S $6.00 TKC, TKM, THKM, TB6, TB8, TBC6, TBC TKUV7R S $ TKUV8R S $ TKUV9R S $ TKUV10R S $ TKUV11R S $ TVUV1R S $ TVUV2R S $ TVUV4R S $ TVUV6R S $6.00 TJ4V, TKL4V, 7 12 TVUV7R S $6.00 TJH6S, TKL12S TVUV8R S $ TVUV9R S $ TVUV10R S $ TVUV11R S $ TVUVR S $ TPUV1 S $ TPUV2 S $ TPUV4 S $ TPUV6 S $60.00 R Frame TRL, TRP 5 12 TPUV7 S $ TPUV8 S $ TPUV9 S $ TPUV10 S $ TPUV11 S $ UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4. 2 For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1 for 120 Vac UVRs on all other breaker lines, order Product Number 192A800G1. "S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by "B" suffix not UL listed. Not available with leads out the back on "Q Line." 4 For TB1 with bolt-on limiters. 5 Not available with B suffix leads out back. 6 Not UL listed. 7 GO-15C UL listed for field installation. 8 GO-145A UL listed for field installation. -90 BuyLog Catalog Rev. 12/04 distributed by AA Electric

91 Internal Accessories Internally Mounted Signaling and Controlling Functions Heavy-Duty Undervoltage Release 1 GO-15B Automatically trips breaker when an undervoltage or power outage condition occurs. Special PUSH-TO-TRIP/PUSH-TO-RESET button is used to manually trip the breaker (E-frame only). On J and K frames, the UVR is handle resettable with a cover-mounted button to provide local mechanical tripping. The Heavy-Duty Undervoltage Release (UVR) is designed for applications where repeated UVR trips are anticipated. The manual reset feature prevents breaker reset or possible contact kiss until power is available and reset button is depressed. Mounts in right pole of breaker only. Must be factory installed to incorporate special breaker frame modifications. 2 Motor-operated mechanism cannot be provided when heavy-duty UVR is installed. Voltage Breaker Type ac dc Product Number List Price 24 TEDXUVARS 1 $ TEDXUVBRS 1 $ TEDXUVCRS 1 $54.00 TEB, TED, THED, 12 TEDXUVDRS 1 $54.00 TEC,TB14,5 24 TEDXUVERS 1 $ TEDXUVFRS 1 $ TEDXUVGRS 1 $ TJMDVAS $ TJMDVBS $ TJJ, TJK, THJK, TJD, 240 TJMDVCS $ TJC, TB4, TBC4 12 TJMDVDS $ TJMDVES $ TJMDVFS $ TKMDVAS $ TKMDVBS $ TKM, THKM, TKC, TKMDVCS $ TB6,TB8, TBC66, 7 12 TKMDVDS $ TBC TKMDVES $ TKMDVFS $ Not UL listed when field installed. 2 For replacement purposes, order from page -84 using field replacement Product Number. Add "B" suffix for leads exit from back of breaker; for price, multiply List Price by For TB1 with bolt-on limiters. 5 Not available with B suffix leads out back. 6 Not UL listed. 7 GO-15A. 8 Not available for two-pole TEB, TED. Order TEDBAR. 9 Changes circuit breaker interrupting capacity to: 600 Vac, 480 Vac, 240 Vac, for TFC, TFJ, TFK and THFK only. 10 UL listed for field installation. 11 Mounts in center pole with leads out left side. 12 GO-15C. 1 GO-145A. Bell Alarm Switches Dummy Trip 1 GO-15B Product Number Breaker UL Listed When Factory Installed Type Base No. Suffix List Price TEB, TEC, TB1 TEDBAR or $ S TED, THED, THLC1 TEDBAL 5,8 $ TFC, TFJ, TFK, THFK, THLC2, THLC4, TLB4 TFKBAAR 9,10 S $ TJC, TJJ, TJK, THJK TB4, TBC4, TJD TJKBAAL 11 S $ TKC, TKM, THKM, TB6, TBC6, TBC8, TB8 TKMABAAL 11 S $ TJL, TKL TJVBALS S $ TKVBALS $ (R Frame) TRL, TRP TPSBAS S $ Blown Fuse Detector-Three-Coil Shunt Trip GO-15B Product Number Breaker UL Listed When Factory Installed Type Base No. Suffix List Price TED, THED, TEC 5 TEDST16 RS $ TFJ, TJK, THFK, TFC TFKBFD16 LS or RS $ TJJ, TJK, THJK, TJD, TJC TJKST16 LS $ TKM, THKM, TKC TKMAST16 LS $ (R Frame) TRL, TRP TPST16 S $ GO-15B Breaker Type Product Number List Price E150 Internal accessories for these noninterchangeable No FJ225 breakers require factory-installed dummy trips. Charge JJ400 Automatically supplied when accessories are ordered. FK225 TFKYT2 (two-pole) $ FK225 TFKYT (three-pole) $ JK400 TJKYT (two-pole, three-pole) $ JK600 TJKYT6 (two-pole, three-pole) $ KM800 TKMAYT (two-pole, three-pole) $ KM1200 TKMAYT12 (two-pole, three-pole) $ Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -91

92 External Accessories Cable Operators Spectra Flex Cable Operators UL Listed File E 5725 Reduced installation costs: Simpler, faster installation No special alignment required Optimized panel layout: Breaker mounting position is independent of flange-mounted handle location Covers a full spectrum of enclosure types and sizes: Flange-mounted handle for NEMA Types 1, R, 12 and 1 enclosures Flange-mounted handle for NEMA 4/4X enclosures optional Broad range of enclosure sizes and breaker mounting configurations 8 different operating cable lengths available from to 10 feet For circuit breaker types E150, SE150, SF250, SG600 and SK1200 Force and motion transmitted independently of breaker mounting plane or position relative to handle location Common breaker mounted operator for SE150 and SF250 frames Spectra Flex cable operating mechanisms are suitable for application with GE circuit breakers mounted in a wide variety of flanged enclosure types and sizes. Flange-mounted handle mechanisms are available for NEMA Types 1, 12 or 1 enclosures in either 6 inch (Model SCH1) or 10 inch (Model SCH2) handle lengths. Corresponding mechanisms, SCH1X and SCH2X, are available for NEMA Type 4/4X enclosures. Handle mechanisms are suitable for either left or right flange operation. The handle mechanism is combined with one of eight operating cables, with lengths from to 10 feet, to cover a broad range of possible breaker mounting locations in the enclosure. The cable links the handle mechanism to the breaker-mounted operating mechanism and transmits the mechanical force and motion of the handle mechanism to the breaker mounted mechanism. The force and motion is transmitted independently of the breaker mounting plane or location relative to the location of the handle mechanism, provided only that the bending radius of the cable is not less than inches. No mounting reinforcement of the breaker or enclosure flange is required. The breaker-operating mechanism mounts directly to the face of the breaker and does not involve any mounting interface with the enclosure. A standard breaker mounting screw kit for tapped holes is furnished with each mechanism to mount the breaker in the enclosure. See page -9 for ordering and pricing information. -92 BuyLog Catalog Rev. 12/04 distributed by AA Electric

93 External Accessories Cable Operators How to order Use the circuit breaker mounting zone dimension table to determine the correct cable length for the application and ensure that the -inch minimum bending radius is not violated. Select the breaker mounted mechanism, operating cable and handle mechanism below. Order as separate components. Publication References Breaker types E150, SE150, SF250, SG600 Breaker type SK1200 See Section 21 for publication ordering information. GEH-6290 GEH-6291 Maximum Dimensions in Inches To determine the maximum mounting dimensions for 60-through 120-inch-long operating cables, add the respective additional lengths to the 48-inch cable maximum dimensions. (Example: Add 12 inches to E, F and G dimensions for 60-inch cable length.) When cable is installed, the minimum cable bend radius should not be less than inches. The minimum cable bending requirement must be met to ensure a safe operating environment. Circuit Breaker Mounting Zone Dimensions Maximum Mounting Dimensions (in.) Box 6" Cable 48" Cable Depth E 1 F G E 1 F G 8" " " " " " " Maximum E Dimension only if F = 4.5" Breaker and Handle Mechanisms Operating Cables Flange-Mounted Handle Mechanism Breaker Mounted NEMA Enclosure Type 1, R, 12, 1 NEMA Enclosure Type 4, 4X Circuit Mechanism 6" 10" 6" 10" Breaker Product List Price Product List Price Product List Price Product List Price Product List Price Type Number GO-144A Number GO-144A Number GO-144A Number GO-144A Number GO-144A E150 SCOM1A $96.00 SE150 SCOM1EF $1.00 SF250 SCOM1EF $1.00 SCH1 $ SCH2 $22.00 SCH1X $ SCH2X $7.00 SG600 SCOM1G $ SK1200 SCOM1K $ SCH2K $22.00 SCH2KX $7.00 GO-144A Circuit Breaker Type E150, SE150, SF250, SG600 SK1200 Cable Product List Product List Length Number Price Number Price ' SCL $91.00 SCH $ ' SC4L $ SC4H $ ' SC5L $ SC5H $ ' SC6L $14.00 SC6H $ ' SC7L $ SC7H $ ' SC8L $16.00 SC8H $ ' SC9L $ SC9H $ ' SC10L $ SC10H $27.00 Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -9

94 External Accessories Flange-Mounted Operators Type STDA Flange Handles and Variable Depth Operating Mechanisms Designed to meet automotive duty specifications NEMA 12/1 and 4/4X UL Component Recognized components, File E-5725l CSA LR 1026 For right or left hand flange mounting field convertible Mounting dimensions to fit standard flange enclosures 8 inches 24 inches deep Detailed installation instructions Superior strength Flange Handle Construction Rugged die cast housing with provisions for locking in OFF position with up to three /16-inch to 5/16-inch padlocks O-ring seals for dirt-tight/oil-tight duty Gusseted, /2-inch thick double-sided steel handle with large, red-black self-extinguishing grade plastic grip. Flange Handle Selection GO-144A Product Number STDA1 (6 inch) and STDA2 (10 inch) flange series handles are interchangeable. While the SE150 through SG600 operating mechanisms can be easily operated with the 6-inch STDA1 handle, the 10-inch STDA2 may be used to obtain lower operating force and/or to provide a proportionally larger handle on large enclosures. STDA and STDAX can be used only with SDOM6 (for SK1200) operating mechanism. Flange Stiffener Kit or Extended Length Drive Rod, Product Number TDSR GO-144A Provides rigid /8-inch diameter rod between STDA handle mounting surface (flange or center mullion) and operating mechanism when STDA handle would otherwise not be rigidly supported. Rod length is 22 inches and my be cut to appropriate length. Also used as extended-length drive rod for SDOM1A and SDOM when standard 16 inch rod is not long enough. (Operating mechanism Product Number SDOM6 for SK1200 includes two 22" unique /8-16x22 inch flange stiffener rods, Product Number TDSR and drive rod.) Operating Flange Extended Mechanism Stiffener Kit Drive Rod List Product Number Product Number Product Number Price SDOM1A, SDOM, TDOM1A through TDOM TDSR TDSR $29.50 SDOM4, TDSR TDOM4 through TDOM7 (16" supplied with TDSR1 $28.00 operating mechanism) Extended Drive Stud, Product Number TDS1, TDS2 GO-144A This optional drive study permits locating the operating mechanism 1-5/16 inches farther to the left (When flange handle is on right side) or to the right (when handle is on the left side) to accommodate specific mounting restrictions. Not suitable for use with SDOM4, SDOM6, TDOM4 and TDOM5 operating mechanisms. NEMA 12/1 NEMA 4/4X Nominal Installation Drilling Flange Handle List Flange Handle List Length Instruction Template Product Number Price Product Number Price Inches Number Number STDA1 $82.50 STDA1X $ STDA2 $94.50 STDA2X $ GEH-514 GEH-514 STDA $94.50 STDAX $ Operating Mechanism Selection GO-144A Circuit Breaker Flange Handle Operating Mechanism List Type Product Number Product Number Price SE150 STDA1, 1X (6 inch) SDOM1A $67.00 SF250 or SDOM $76.50 SG600 STDA2, 2X (10-inch) SDOM4 $ SK STDA, X SDOM6 1 $0.00 TEB, TED, THED, TEC SDOM1A $67.00 TB1 (150A), SDOM1A $67.00 TEC with TECL SDOM1AP $15.00 THLC1 (150A) TDOM1D $ TFJ, TFK, TFC (225A) TDOM 2 $76.50 J-Frames, TJC (400, 600A) STDA1, 1X (6 inch) TDOM4 $ TB4 (400A) TJH/TJL 4 or (600A Max) STDA2, 2X (10-inch) TDOM5 $ K-Frames, TKC (800A, 1200A) 5, THLC2 (225A), THLC4 TDOM6 $0.00 TLB4 (400A) TB6 (600A), TB8 (800A) TKH/TKLD 6 (1200A Max) TDOM7 $ Requires STDA or STDAX (10 inch, SK1200 only). Not suitable for left hand mounting. Includes TJ/THJ/TJL with MicroVersaTrip R trip unit. 4 Use TDOM5 for TJH/TJL with MicroVersaTrip R RMS-9 trip unit. 5 Includes TK/TKL with MicroVersaTrip R trip unit. 6 Use TDOM7 for TKH/TKL with MicroVersaTrip R trip unit. Operating Mechanism Extended Drive Stud List Product Number Product Number Price SDOM1A, SDOM, TDS1 TDOM1A through TDOM $29.50 TDOM6, TDOM7 TDS2 $29.50 Door Hardware NEMA 12/1 and 4/4X GO-144A Type TDV door hardware provides sealing and interlocking of /4-inch nominal door depth hinged on left or right. Interlocking design requires use of screwdriver to release. When used with an STDA flange handle and operating mechanisms, disconnect or circuit breaker cannot be turned on unless door and door hardware have been closed. For noninterlocking type, one bracket in kit is not used. Use of third point latch recommended for doors 40 inches or longer. Door Hinged Door Hinged on Left on Right List Description Product Number Product Number Price NEMA 12/1 two point interlocking door hardware kit TDV1 TDV1L $14.00 NEMA 4/4X two point interlockingdoor hardware kit TDV1X TDV1LX $ Third point latch kit for above TDV TDVL $ BuyLog Catalog Rev. 12/04 distributed by AA Electric

95 External Accessories Flange-Mounted Operators Auxiliary Contact Kits Available SPDT and DPDT and actuated by operating mechanism yoke. GO-144A When STDA Auxiliary Contact Kit Used With handle is on SPDT DPDT Operating Mechanism Right Left Product List Product List Product Number Flange Flange Number Price Number Price SDOM1A, SDOM TDAS1L1 SDOM4 $71.00 TDAS1L2 $14.00 TDOM1A, JA TDOM1B, JB TDOM1C TDAS1R1 TDOM1D $71.00 TDAS1R2 $14.00 TDOM SDOM6 TDOM4 TDAS2L1 $71.00 TDAS2L2 $14.00 TDOM5 TDOM6 TDAS1R1 TDOM7 $71.00 TDAS1R2 $14.00 Publication References Instructions: Door Hardware Auxiliary Contact Kit Flange Stiffener Kit or Extended Length Drive Rod Extended Drive Stud Operating Mechanism: SDOM1A through SDOM4, SDOM6 TDOM1A through TDOM1D TDOM TDOM4 and TDOM5 TDOM6 and TDOM7 See Section 21 for publication ordering information. GEH-522 GEH-52 GEH-524 GEH-525 GEH-5684 GEH-515 GEH-517 GEH-518 GEH-519 Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -95

96 External Accessories Door-Mounted Operators TDM Operating Handle, Fixed or Adjustable Shaft TDM Handle Operating Mechanisms, Door Mounted Complete mechanism with handle UL listed, E-5725 Operating mechanism only, UL Component Recognized, E-5725 Complete Mechanism 1 Operating Handle Only with NEMA 1, R, 12 Handle Mechanism Only NEMA 1, R, 12 NEMA 4/4X Breaker Box Depth Product List Product List Product List Product List Type in Inches Number Price Number Price Number Price Number Price GO-144A TQD, THQD Shallow Mount 7/16 TQDHM1 $69.00 TQDOM1 $42.00 Extended Shaft 4 5/ /16 TQDHM2 $82.00 TQDOM2 2 $55.00 Shallow Mount 4 /16 TEFHM1 $69.00 TEFOM1 $42.00 TEB, TEC, TB1, Extended Shaft TED, THED 5-1/8-5 7/2 TEFHM $82.00 TEFOM $55.00 TH1 $ /8-5 1/16 TEFHM4 $82.00 TEFOM4 $ /8-15 TEFHM2 $82.00 TEFOM2 $55.00 Shallow Mount TFC, TFJ, 5 7/8 TFKHM1 $10.50 TFKOM1 $76.50 THCH45,4 $0.00 TFK, THFK Extended Shaft 6 7/8-15 1/2 TFKHM2 $ TFKOM2 2 $80.50 Shallow Mount TJC, TJD, TJJ, TJKHM1 $14.00 TJKOM1 $ /8 TJK, THJK, Extended Shaft TB4, TBC4 TJKHM2 $ TJKOM2 4 $ /8-15 5/8 Shallow Mount TKC, TKM, TKMHM1 $14.00 TKMOM1 $ /16 THKM, TB6, Extended Shaft TBC6, TB8, TBC8 TKMHM2 $ TKMOM2 4 $ /2-17 5/16 TH2 $41.00 TJ4V, TJL Shallow TJVHM1 $14.00 TJVOM1 $ Extended TJVHM2 $ TJVOM2 $ TK4V, TKL Shallow TKVHM1 $14.00 TKVOM1 $ Extended TKVHM2 $ TKVOM2 $ SE150 (GEH-5611) 5 4 /16 SEFHM1 $79.00 SEFOM1 $ /8-15 SEFHM2 $81.50 SEFOM2 2 $55.00 TH1 $7.00 SF250 (GEH-5611) 5 5 7/8 SEFHM1 $79.00 SEFOM1 $ /4-15 1/2 SEFHM2 $81.50 SEFOM2 2 $55.00 SG600 (GEH-565) 5 5 7/8 SGHM1 $14.00 SGOM1 $ /8-15 5/8 SGHM2 $ SGOM2 4 $ TH2 $41.00 THCH45,4 $0.00 SK1200 (GEH-5612) 5 6 SKHM1 $14.00 SKOM1 $ SKHM2 $ SKOM2 4 $ Handle assembly and operating mechanism separately packaged. 2 For 15-inch long shaft order Product Number 788A81G10, List Price, $40.00, GO-15B. For 20-inch long shaft order Product Number 788A81G21 List Price $40.00, GO-15B. Provides interlocking for J600, SG600 SK1200, and K1200 breakers when used with the extended shaft operating mechanism. For interlocking with E150/SE150, F225 and SF250 order special shaft Product Number 788A82G1, List Price, $40.00, GO-15B. 4 For 15-inch long shaft order Product Number 788A82G2, List Price $40.00, GO-15B. For 20-inch long shaft order Product Number 788A82G5, List Price $40.00, GO-15B. 5 Installation instructions publication number. 6 MOD 1 is 7 7/16; MOD 2 is 8 /2. 7 MOD 1 is 7 /16-17 /16; MOD 2 is 7 15/ /16. Handle Accessories for TDM Operating Mechanisms GO-19 Device Product Number List Price Replacement neoprene gaskets for NEMA 1, R and 12 enclosures Use with TH1 788A742P $2.80 Use with TH2 788A742P4 $ BuyLog Catalog Rev. 12/04 distributed by AA Electric

97 External Accessories Door-Mounted Operators TDR Handle on TEC Mag-Break TDR Integral Handle Mechanism 1 Suitable for NEMA 12 Applications 2 Handle Door Ring - Interlock Catch Kit NEMA 12 Gasket Kit Vertical Mounting Horizontal Mounting List Ship Product List Product List Breaker Type Product Number Product Number Price Weight Number Price Number Price GO-144 TEB, TEC, TB1-B, TED, THED TEFR1B TEFR1HB $ SEFRDRCK $11.25 THLC1 TLC1RB TLC1RHB $ SEFRGSK $4.00 TFC, TFJ, TFK, THFK TFKR1B TFKR1HB $ L48G5 $11.25 THLC2, 4; TLB4 TLC4RB TLC4RHB $ L48G9 $11.25 TJD, TJC, TJJ, TJK, THJK, TB4, TBC4 TJR1B TJR1HB $ L48G2 $20.25 SGRGSK $11.00 TKC, TKM, THKM, TB6, TB8, TBC6, TBC8 TKMR1B TKMR1HB $ SKRDRCK $21.75 SKRGSK $11.00 TJ4V, TJL TJVR1B TJVR1HB $78.50 TJVR1BKLP 4 TJVR1HBKLP 4 $ L48G7 $20.25 SGRGSK $11.00 TKL TKVR1B TKVR1HB $ TKVR1BKLP 4 TKVR1HBKLP 4 $ L48G8 $21.75 SKRGSK $11.00 SE150, SF250 (GEH-5609) 6 SEFR1 5 SEFR1H 5 $ SEFRDRCK $11.25 SEFRGSK $4.00 SG600 (GEH-5654) 6 SGR1 SGR1H $ SGRDRCK $20.25 SGRGSK $11.00 SK1200 (GEH-5610) 6 SKR1 SKR1H $ SKRDRCK $21.75 SKRGSK $ Not suitable for use with mine duty or heavy duty UVR breakers. 2 Requires Gasket kit. Shipped 12 per pack. 4 With provision for Kirk Key Interlock. Lock supplied by customer (type FN with one-inch bolt projection - bolt extended, key removable with breaker open). 5 For F250 Frame also order adapter bracket, Product Number SFRAK, no charge when ordered with handle. 6 Installation instructions publication number. See Section 21 for publication ordering information. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -97

98 External Accessories Motor Operators and Plug-in Hardware Motor Mounted Mechanism UL Listed GO-15S Voltage Vac Product List Installation Breaker Type 50/60 Hz Vdc Number Price Instructions TEB, 1 TEC, TED, 1 24 TEDMOMA8 $ THED, TB1, THLC TEDMOMA1 $ ,5 TEDMOMA2 $ TFKMOMA8 $ TFKMOMA9 $ TFC, TFJ, TFK, THFK TFKMOMA1 $ ,5 250 TFKMOMA2 $ TJKMOMA8 $ TJC, TJJ, TJD, TJK, 48 TJKMOMA9 $ THJK, TB4, TBC TJKMOMA1 $ ,5 250 TJKMOMA2 $ TKMMOMA8 $ TKC, TKM, THKM, TB6, 48 TKMMOMA9 $ TB8, TBC6, TBC TKMMOMA1 $ ,5 250 TKMMOMA2 $ SEMOM1 $ SE SEMOM2 $ SEMOM8 $ GEH SEMOM9 $ SFMOM1 $ SF SFMOM2 $ SFMOM8 $ GEH SFMOM9 $ SGMOM1 $ SG SGMOM2 $ SGMOM8 $ GEH SGMOM9 $ SKMOM1 $ SK SKMOM2 $ SKMOM8 $ GEH SKMOM9 $ For TJ4V, TJL, TKL, TK4V ONLY 7 GO-15B Mechanism Mounting Plate Breaker Type Volts Product Number Product Number List Price TJ4V, TJL TKL, TK4V 120 Vac 125 Vdc TJKMOMA1 286A7558G8 $ Vac 4,5 250 Vdc TJKMOMA2 286A7558G8 $ Vdc TJKMOMA8 286A7558G8 $ Vdc TJKMOMA9 286A7558G8 $ Vac 125 Vdc TKMMOMA1 286A7558G7 $ Vac 4,5 250 Vdc TKMMOMA2 286A7558G7 $ Vdc TKMMOMA8 286A7558G7 $ V TKMMOMA9 286A7558G7 $ Mounting Screw Kit for Motor-Operated Mechanism 8 GO-148B Breaker Type Mounting Screw Kit Product Number List Price TED, TB1 4L564G7 $.50 6 TFJ, TFK 4L564G1 $ TJJ, TJK, TB4 4L564G2 $87.00 SG600 SGMSKMOM $ TKM, TB6, TB8, SK 4L564G $ For use on -pole breaker only. 2 Motor-operated mechanisms must have Code Date or later for use with THLC1. TEDMOMA1 not rated at 50 hertz. 4 Suitable for use at 208 Vac. 5 Not UL listed. 6 GO-15B. 7 Requires mounting plate which is supplied at no charge when ordered with mechanism. Order both items. 8 Required with plug-in mounting base assembly when used with motor-operating mechanisms or TDR integral-handle kits. Furnished no charge when ordered with mounting base. 9 GO-15S. Mounting Screw Kit for TDR Integral Handle Motor Operated Mechanism on SF-Frame breaker GO-15B Mounting Screw Kit Breaker Type Product Number List Price TFC,TFJ,TFK 4L564G4 $8.60 TEC,TED,TB1-B, TJC, TJJ, TJK, TB4, TBC, TKC, TKM, No Special Mounting TB6, TB8, TBC6, TBC8 Screw Required -98 BuyLog Catalog Rev. 12/04 distributed by AA Electric

99 External Accessories Mechanical Interlocks and Locking Devices Mechanical Interlocks Walking Beam Type Externally Mounted UL Component Recognized Requires Breaker with Special Factory Drilling. Panel Order 2 Breakers per Interlock, Thickness Specifying "Drilled for Mech. Interlock" List Price Breaker Type in Inches Product Number GO-15B E-150, TB TEDMI $41.00 F TFKMI $41.00 TJJ, TJK, TJ4V, 0.8 TJKMIB $41.00 THJ4V, TB4 1.0 TJKMIE $41.00 TKM, TK4V, TB6, TB TKMMI $ These face-mounted interlocks prevent two adjacent breakers from being in the ON position at the same time. Adapter Kit Required when using handle Face-mounted operator (TDM) or Spectra RMS Interlock List Price motor operator. List Price Breaker Type Product Number GO-15S Order separately. GO-15S SE150, SF250 SEFFMI $41.00 SEFFMIAK 2 $.50 SG600 SGFMI $68.00 SGFMIAK $42.00 SK1200 SKFMI $68.00 SKFMIAK $59.50 Handle-Locking, Handle-Extension Devices GO-15B Breaker Type Device Product Number List Price TQB, TQC, TQL Handle locking THL10 $ TQB, TQC, TQL Snap-on handle tie - trip indicating TQHT1 $2.0 4 TQL Snap-on handle tie - solid THT104 $2.0 4 TEY Handle locking TEYLD1 $5.00 E150 Line Handle locking TLD $5.00 F225 Line, THLC2, 4 Handle locking TFKLD1 $6.00 SE150, SF250 Handle locking SBD1 $ SK1200 Handle extension - replacement SKHDLEXT $ Standard Padlocking Devices 10 GO-15B Breaker Type Device Product Number List Price TQC TQPLD1 $4.70 TQD TQDPLD1 $ TQDL TQDLPDL1 $ TQB, TQL THP100 $ TEY TEYPLD1 $9.00 E150, TB1 TEFPLD1 $8.00 THLC1 TLC1PLD1 $17.00 F225 TFKPLD1 $4.00 THLC2, THLC4, TLB4 TLC4PLD1 $22.00 J600 Line TJKPLD1 $8.00 K1200 Line TKMPLD1 $28.50 SE150, SF250 SEPLD $ SG600 SGPLD $ SK1200 SKPLD $ EUSERC Approved Factory Installed Only GO-15B Breaker Type Product Number List Price TQD TQDPLD2 $2.00 E150 TEDPLD2 $2.00 SE150, SF SEFPLD2 $ SG600 SGPLD2 $ J600 TJKPLD2 $48.00 SK1200 SKPLD2 $ THLC1 THLC1PLD2 $48.00 THLC2/4 THLC4PLD2 $48.00 PowerMark Gold Main Circuit Breaker Kit GO-18M Description Product Number List Price Order appropriate TQMH000 $10.50 THQL (10 kaic) or THHQL breakers separately. Q Line, TEY Mounting Accessories GO-15B Description Breaker Type Product Number List Price Back Mounting plates 1-pole THQC TQCBMPA1 $8.0 Screw Type 2-pole THQC TQCBMPA2 $9.80 THQC Breaker held to -pole THQC TQCBMPA $12.00 Mounting Plate by screw clip 10-pole THQC TQCBMPA10 $2.00 Snap In 1-pole TQCGFBMPA1 $ THQC, THQC-GF 2-pole TQCGFBMPA2 $ snaps in to spring retaining clip -pole TQCGFBMPA $ pole TQCGFBMPA10 $ Bolt-on Base for THQB, TEY -pole TEYB $ pole THQC TQCFMP1 $8.0 Front-mounting Plates 7 2-pole THQC TQCFMP2 $9.80 -pole THQC TQCFMP $ pole THQC TQCFMP10 $ pole Plug-in Mounting Base (70 Amp) -pole TQL 571B595DDG2 $ pole Plug-in Mounting Base (70 Amp) 2-pole TQL 571B595DDG1 $ pole Plug-in Mounting Base (100 Amp) -pole TQL 565B87G1 $ pole Plug-in Mounting Base (100 Amp) 2-pole TQL 565B87G2 $ Pack of 48 Front/Rear Mounting Clips 1 & 2-pole $48.00 THQCFMK 15-60A THQC Pack of 24 DIN rail clips DIN rail THQC THQCDIN $ GO-144. Not suitable with THCH45 handle. Compatible with motor operator only. Product Number SGFMI cannot be used with the handle operator. 4 GO-17A. 5 GO-15S. 6 GO-1. 7 Not UL listed. 8 GO-14A. 9 Price is per pack. 10 Suitable for circuit breakers used in group mounted panelboard construction only except for J600, K1200, SE150/SF250, SG600 and SK1200 which screw down to face of breaker. 11 Field installable. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -99

100 External Accessories Breaker Mounting Hardware and Kits Breaker Mounting Screw Kits GO-15S Spectra RMS Kit Screw Size Application Breaker Type Product Number (inches) List Price SEMSK1 10-x2 7/8 (std.) $2.10 SE150 For use on mounting SEMSK 8-2x2 7/8 (opt.) $2.10 plates with tapped SFGMSK x /4 (std.) $6.10 SF250 holes (4 screws SFMSK1 10-2x /4 (opt.) $6.10 and lockwashers) SG600 SFGMSK x /4 $6.10 SK1200 SKMSK1 5/16-18x1 1/4 $8.70 SEMSK2 10-2x (std.) $2.10 SE150 For use on mounting SEMSK4 8-2x (opt.) $2.10 plates with clearance SFGMSK x4 (std.) $6.10 SF250 holes (4 screws, SFMSK2 10-2x4 (opt.) $6.10 lockwashers and nuts) SG600 SFGMSK x4 $6.10 SK1200 SKMSK2 5/16-18x1 /4 $8.70 Breaker Mounting Screw Kits GO-15B Application Breaker Type Product Number List Price 1-pole E150 4L162G1 $ and -pole E150 SEMSK4 $ For use on mounting THLC1 4L162G22 $2.10 plates with clearance F225 SFGMSK2 $ holes THLC2, 4, TLB4 4L162G24 $5.70 J600 4L162G20 $4.50 K1200 SKMSK2 $ pole TE, E150 4L162G7 $ and -pole E150 SEMSK $ THLC1 4L162G2 $2.10 For use on mounting 2- and -pole TQD/THQD 4L184G18 $ plates with tapped holes F225 SFGMSK1 $ THLC2, 4, TLB4 4L162G25 $5.70 J600 4L162G11 $4.50 K1200 SKMSK1 $ mounting screws for TQBS1 connecting low tab to THQB (packaged 24/kit) panel board $6.00 Cup washer 254V644P1 E150 (for mounting 1-pole breakers) (2 req'd per breaker) $0.10 Back-Connected Line and Load Studs GO-15B Length, Back of Breaker Product Breaker Type Amperes in Inches Std Pkg Number List Price /2 (short) 1 TEF1 $27.00 E150 4, TB1 4, 4 1/2 (long) 1 TEF2 $27.00 THLC /2 (short) 1 TEF $ /2 (long) 1 TEF4 $1.50 TFJ 4, TFK 4, 2 2/2 (short) 1 TFK1 $ THFK 4 5 1/2 (long) 1 TFK2 $59.50 J600, TJ4V, /2 1 TJK1 $8.50 TB4, TJL /2 1 TJK2 $ K1200, 5 1/2 2 TKM11 $ TB6, TB8 8 2 TKM12 $ SE /2 (short) 1 TEF1 $ /2 (long) 1 TEF2 $ /2 (short) 1 TEF $ /2 (long) 1 TEF4 $1.50 SF /2 (short) 1 TFK1 $ /2 (long) 1 TFK2 $59.50 SG /16 (short) 2 SGBCS1 $ /16 (long) 2 SGBCS2 $ SK /2 2 TKM11 $ TKM12 $ Back-Connected Center Studs for Dual Voltage Applications GO-15B -pole only. Order frame and trip unit separately. Not UL listed. Breaker frame can be supplied with center stud connections permitting operation at both voltages with one trip unit rating. At the higher voltage, connection is made at the line and load terminals only and thus the trip unit carries all the load current. At the lower voltage, where current is double, connection is also made through the center studs permitting half the current to bypass the trip unit. At either voltage, full-load current is carried by the breaker contacts. Trip Unit Dual Voltage Maximum Frame Maximum Frame Only Ampere Rating Ampere Rating Product Number List Price 5 225A 110 TFK26F000DV $ A 200 TJK46F000DV $ A 00 TJK66F000DV $ A 400 TKM86F000DV $ A 600 TKMFDV $ GO-15S. GO148C. Price is per screw. Packaged in quantity of 24. Must be ordered in multiples of For proper clearance between poles, a short and long stud must be assembled adjacent to each other. 5 Price includes center studs, but does not include line and load back-connected studs or trip unit BuyLog Catalog Rev. 12/04 distributed by AA Electric

101 External Accessories Lugs and Associated Hardware Breaker with Line and Load Studs Lugs, Line Shields, Covers and Bus Connectors GO-15B Accessory Wire Range For Use With Product Number List Price Copper-Aluminum Lugs (1) #14-6 Cu, #12-2 Al TQC (15-60A) (Non DIN Rail) TQAL $1.50 (1) #4-1/0 Cu-Al TQC (70-100A) TQAL4 $1.50 (1) #1-00 kcmil Cu-Al TQD TCAL25 $ (1) #14-8 E150, THLC1, TB1, (15-0A) TCAL14 $.00 (1) #14- Cu, #12-1 Al E150, THLC1, TB1, (15-60A) TCAL12 $.00 (1) #6-2/0 Cu, #4-2/0 Al E150, THLC1, TB1, (70-90A) TCAL12A $.00 (1) #-/0 Cu, #1-/0 Al E150, THLC1, TB1, ( A) TCAL15 $.00 (1) #4-00kcmil Cu-Al F225 TCAL24 $8.00 (1) #4-00kcmil Cu-Al THLC2 TCAL27 $10.00 (1) 6-600kcmil or (2) 2/0-250kcmil Cu-Al J400, TB4, J600 (Thru 400A), TJD TCAL4 $14.00 (2) 4/0-50kcmil Cu or (2) kcmil Al J600 ( A) TCAL6 $2.00 (1) 750 kcmil Cu-Al J400, TJD TCAL47 $26.00 (1) /0-500kcmil or (2)/0-250kcmil Cu-Al TLB4, THLC4 TCLK4 $49.00 (2) 1/0-250kcmil or (1) #4-600 kcmil Cu-Al K1200, TB6 (00-400A) TCAL41 $8.00 (2) 2/0-500 kcmil Cu-Al K1200, TB6, ( A) TCAL61 $40.00 () /0-500 kcmil Cu-Al K1200 ( A), TB8 TCAL81 2 $47.00 () /0-500 kcmil Cu-Al TK4V - Load end TCAL91 2 $47.00 (4) kcmil Cu or (4) kcmil Al K1200 (1200A) TCAL121 4 $76.00 () 750 kcmil Cu-Al TCAL122 $ (4) kcmil Cu or (4) kcmil Al TK4V - Load end TCAL11 4 $76.00 Copper Only Lugs #14-2/0 E150, TB1 (thru 150A) TC012 $6.00 With Follower and Extra Plating (1) kcmil or (2) 1/0-250 kcmil Cu J400, TB4 TC04 $21.00 (2) kcmil Cu J600 TC06 $4.00 (1) 1/0-600kcmil or (2) 1/0-250 kcmil Cu K1200, TB6 (00-400A) TC041 5 $8.00 (2) 2/0-500 kcmil Cu K1200, TB6, ( A) TC061 $40.00 () /0-500 kcmil Cu K1200 ( A), TB8 TC081A $5.00 () /0-500 kcmil Cu TK4V - Load end TC091 $5.00 (4) kcmil Cu K1200 (1200A) TC0121 $80.00 (4) kcmil Cu TK4V - Load end TC011 $80.00 Line Shield TEB, TEC, TED, THED TEDLS $5.10 TFJ, TFK, TFC TFKLS $16.25 TJJ, TJK, TJC TJKLS $14.25 Lug Cover, TKM Breaker TC041, TCAL41 Lugs 789A448G 6 $5.00 (two per breaker) TC061, TCAL61, TCAL81 Lugs, TC081A 789A448G1 $5.00 TC0121; TCAL121 Lugs 789A448G2 $5.00 TH4V, THK9V 286A8066G1 $.50 Connector (back strap) TKM TKMC1 $8.00 Line voltage control wire kit J600 TJLVK 7 $9.00 for terminating control wire at breaker lugs K1200 SKLVK 7 $ GO-15F. 2 Not suitable for 100 A aluminum conductor. GO-15S. 4 Suitable for 500 kcmil copper for voltage drop considerations. 5 Not UL listed. 6 End cover supplied with 800A frame is used as lug cover. 7 -pole kit. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -101

102 External Accessories Lugs and Associated Hardware Spectra RMS Lugs, Lug Covers, and Bus Lugs GO-15S Wire Range (Qty.) Accessory For Use With Copper Aluminum Product Number Description Ampacity Range 1 List Price SE150 (1) #12-/0 (1) #12-/0 TCAL18 Single lug $.00 SF250 (1) #8-50 kcmil (1) #8-50 kcmil TCAL29 Single lug $8.00 (2)2/0-500 kcmil or (2)2/0-500 kcmil or TCLK265 2-pole lug kit SG $28.00 Plated extruded aluminum (1)#8-600 kcmil (1)#8-600 kcmil TCLK65 -pole lug kit $42.00 lugs for terminating Cu $10.00 copper or aluminum cables () kcmil () kcmil TCAL124 Single lug Al $10.00 SK1200 ()/0-500 kcmil ()/0-500 kcmil TCAL81 Single lug $47.00 (4) kcmil (4) kcmil TCAL125 Single lug $76.00 SE150 SELCK Three lug covers for upper (line) end $5.10 SF250 SFLCK Three lug covers for upper (line) end $9.80 Replacement Lug Covers -pole lug cover for SG1LCK $21.25 and End Covers upper (line) or lower (load) end SG600 -pole lug cover for SG1BCK $7.00 upper (line) or lower (load) end 7 SK1200 SK1LCK Lug cover for upper (line) or lower (load) end 4 $.50 SE150 (1) #12-/0 TCO18 Single lug $6.00 SF250 (1) #8-50 kcmil TCO19 Single lug $21.25 (2)2/0-500 kcmil or TCOK265 2-pole lug kit $42.00 SG600 Plated Copper Lugs (1)#8-600 kcmil TCOK65 -pole lug kit $6.00 () kcmil TCO81A Single lug $5.00 SK1200 (4) kcmil TCO121 Single lug $80.00 () kcmil TCO124 Single lug $ Single lug with.25 SE150 (1) #12-/0 (1) #12-/0 TCAL18LV $6.60 Line voltage control wire kit Quick Connect SF250 (1) #8-50 kcmil (1) #8-50 kcmil TCAL29LV $17.75 for terminating control wire for Control Voltage at breaker lugs SG600 SGLVK -pole kit $9.00 SK1200 SKLVK -pole kit $12.00 Replacement cover SPCOV1 for MicroVersaTrip Plus $1.25 and MicroVersaTrip PM Clear rating plug cover SG600 / SK1200 Cover with access to with provision for wire seal SPCOV2 $1.25 instantaneous set point SPCOV Cover with no access to instantaneous set point $1.25 Lugs and Lug Covers for J and K Frames with MVT-4 and RMS-9 Trip Units GO-15S Standard Lugs Optional Lugs Lug Covers 5 End Covers 5 Sensor Rating Cu/Al List Cu Only List Product List Product List Breaker Type (Amps) Product Number Price Product Number Price Number Price Number Price TCAL4 $ TCO4 $ TJ, TJL with RMS-9 or MVT TCAL6 $ TCO6 $ TCAL81 $47.00 TCO81A $ A8066G $ A8066G2 $.50 TKH, TKL with RMS TCAL121 $76.00 TCO121 $ A8066G1 $ A8066G2 $ TCAL81-Line $47.00 TCO81A-Line $ A8066G $ A8066G2 $.50 K with MVT-4 TRIP UNIT 800 TCAL91-Load $47.00 TCO91-Load $ TCAL121-Line $76.00 TCO121-Line $ TCAL11-Load $76.00 TCO11-Load $ A8066G1 $ A8066G2 $.50 1 Both copper and aluminum cables may not cover full ampacity range. With lug cover for line or load end. 500 kcmil acceptable for voltage drop considerations kA, 480 Vac (SKPA) uses longer lug cover/arc shield on upper end. Use Product Number SKPSHLD for replacement. May be used on other SK1200 devices. 5 Breakers supplied less lugs with end covers. When ordering K-frame breaker and lugs, order appropriate lug covers. 6 GO-15B. 7 Required for line end bus connection BuyLog Catalog Rev. 12/04 distributed by AA Electric

103 External Accessories Neutral Grounds and Sensors Power Distribution Lugs GO-15 Breaker Type Max Amperes Wire Range Product Number List Price SE, TED 125 (2) 4-14 or TCAL19PD $50.00 (1) 2/0-4 Cu only SF 250 (6) 4-14 Cu only TCAL28PD $75.00 SG 400 (12) 4-14 Cu only TCAL40PD $88.00 Neutral Current Sensors For grounded neutral system ground fault applications GO-15S Breaker Type Ampere Rating Product Number List Price 150 TSRG201 $ TSRG202 $52.00 J 00 TSRG20 $ TSRG204 $ TSRG205 $ TSRG206 $ TSKG408 $52.00 K 1000 TSKG410 $ TSKG412 $52.00 Power Distribution Lugs Fungus and Moisture Proofing Poles GO-15B Q Line E150 F225 J600 K1200 TB-1 TB-4 TB-6, 8 List Price List Price List Price List Price List Price List Price List Price List Price 1, 2 $8.90 $28.50 and $22.25 $62.50 $84.00 $84.00 $ $62.50 $21.00 $ Test Set for MicroVersaTrip Plus, MicroVersaTrip PM and MicroVersaTrip RMS-9 Trip Units GO-245B Description Product Number List Price Portable Test Set TVRMS2 $ Neutral Current Sensor Rating Plug Removal Tool Product Number GO-15S List Price TRTOOL $12.00 "Naval Use" Molded Case Circuit Breakers The following molded case circuit breaker types are optionally available as UL listed per Standard 489, Supplement SB for naval use: THQB THQC SE150 SF250 SG600 SK1200 Contact GE sales office for price and delivery. Special Calibration Contact GE sales office for availability. May void UL listing status. Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -10

104 External Accessories Plug-in Hardware Each plug-in mounting base assembly includes all mounting hardware, studs, and male or female connectors for attachment to one end of breaker. Studs are of different length so by using proper combinations of PD1 and PD2 units, adequate electrical spacing will be assured between adjacent breakers, i.e., a short-long-short (SLS) unit must be used adjacent to a long-short-long (LSL) unit. Two-pole breakers of the E150 line require an open-long-short (OLS) unit on one end of the breaker and a short-long-open (SLO) on the other since these breakers are built with the normal left pole missing while the mounting bases are built from standard three-pole molded supports. Spectra RMS and all other two-pole breakers are basically three-pole devices with the center pole omitted. When these breakers are to be mounted side by side, a short-open-short (SOS) unit must be used on one end and a long-open-long (LOL) on the other. Horizontal studs are normally supplied with the flat surface of studs at right angles to the long axis of the breaker. If vertical studs are desired, substitute "C" for "D" in the product number, e.g., TE1PC1 (vertical) or TE1PD1 (horizontal). The optional mounting plate (TMP1, etc.) accurately locates and supports the pair of line and load plug-in mounting-base assemblies and provides a convenient means to attach the entire unit to a metal structure, and serves as a dead front barrier. New drawings are available for customers who prefer to fabricate their own mounting plates. Plug-in Mounting Base with Hardware Product Number TF2PD2 shown Plug-in Mounting Base Product Number TK12PD2A shown Plug-In Mounting Base Assembly Plug-In Mounting Bases - 2 Required Per Breaker GO-15B Ampere Breaker Stud Configuration Product Optional Mounting Base Rating Type No. Poles PD1 PD2 Number List Price Product Number List Price E OLS SLO TE12PD1,2 $ TMP1 $ TB1 SLS LSL TE1PD1,2 $75.00 TMP5 $40.00 SE150 SLS LSL TE1PD1,2 $75.00 TMP1 $ F225 2 SOS LOL TF22PD1,2 $00.00 TMP2 $40.00 SLS LSL TF2PD1,2 $ TMP2 $ SF250 2 SOS LOL TF22PD1,2 $00.00 TMP2 $40.00 SLS LSL TF2PD1,2 $ TMP2 $40.00 J400 2 SOS LOL TJ42PD1A,2A $ TMP $40.00 SLS LSL TJ4PD1A,2A $ TMP $ SOS LOL TJ42PD1A,2A $ TMP6 $50.00 TB4 SLS LSL TJ4PD1A,2A $ TMP6 $50.00 SG400 SLS 2 LSL 2 SGPC1, SGPC2 $ SMP $40.00 J600, TJ4V, TJL 2 SOS LOL TJ62PD1A,2A $ TMP $40.00 SLS LSL TJ6PD1A,2A $ TMP $ SOS LOL TK62PD1A,2A $ TMP4 $50.00 K1200, TKL, TK4V 600 SLS LSL TK6PD1A,2A $ TMP4 $50.00 TB6 2 SOS LOL TK62PD1A,2A $ TMP7 $50.00 SLS LSL TK6PD1A,2A $ TMP7 $50.00 SG600 SLS 2 LSL 2 SGPC7 $ SMP $40.00 K1200, TK4V, TKL 2 SOS LOL TK82PD1A,2A $ TMP4 $50.00 SLS LSL TK8PD1A,2A $ TMP4 $ SOS LOL TK82PD1A,2A $ TMP7 $50.00 TB8 SLS LSL TK8PD1A,2A $ TMP7 $50.00 SK800 SLS LSL TK8PD1A,2A $ TMP4 $ SOS LOL TK102PD1A,2A $ TMP4 $50.00 K1200, TK4V, TKL 1000 SLS LSL TK10PD1A,2A $ TMP4 $50.00 SK1200 SLS LSL TK10PD1A,2A $ TMP4 $ SOS LOL TK122PD1A,2A $ TMP4 $50.00 K1200, TK4V, TKL 1200 SLS LSL TK12PD1A,2A $ TMP4 $50.00 SK1200 SLS LSL TK12PD1A,2A $ TMP4 $ Order -pole base for use with 2-pole Hi Break and 600 Vac breakers. 2 Vertical studs only for SG600 frame. GO-15S BuyLog Catalog Rev. 12/04 distributed by AA Electric

105 External Accessories R-Frame Ground Fault Neutral Sensors GO-245B Current Sensor Rating Neutral Sensor Product Number List Price 1000A TSVG810A $ A TSVG816A $ A TSVG820A $ A Power Break with TPLUGA16 Adapter and 6 TPLUG108 Lugs T-Studs Studs mount to breaker or adapter kit. Studs may be rotated for either vertical or horizontal bus. Product number includes 1 stud. GO-145A Maximum Breaker Ampacity Product Number List Price 1600A TP16FCA $ A TP20FCA $11.00 Type TP16FCA T-Stud Lug Kits GO-245B Kits accept Cu/Al wire and are suitable for direct mounting to breaker. Order one kit per line or load pole. TPLUG108 is suitable for use only with the adapter kits described below. Circuit Breaker Maximum Product Lugs Maximum Cables Wire Range Frame Size Ampere Rating Number per Kit per Pole Cu/Al List Price TPLUG kcmil $9.00 TPLUG kcmil $2.00 Lug Adapter Kits GO-245B Premounts to bus structure allowing cabling or bussing to be completed prior to breaker mounting. Accepts either lugs or crimp type connector terminals. Product number includes adapter and hardware for three-pole line side or three-pole load side connection. Kits include a set of three corresponding T-studs and are suitable for use with from 1 to 6 TPLUG108 lugs per pole or with from 1 to 6 Crimp Lugs (Anderson No. VCEL H1 or equivalent) per pole. Maximum Breaker Ampacity Product Number List Price 1000/1600 A TPLUGA16 $ A TPLUGA20 $ Kirk Key Provision (Factory Installation Only) GO-145A Equips the breaker to accept a zero bolt projection Kirk Key device (supplied by customer) to permit sequencing of breaker operations with other key-type devices. The key remains captured in the breaker frame except when the breaker has been locked in the open position. Not compatible with door interlock and padlock device. Number of Locks Product Number List Price Terminal Block (Factory Installed Only) Type TPLUG408 Lug Kit GO-145A Offers an external means of terminating accessory leads at the breaker. A maximum of 18 terminals can be supplied on each side of the breaker (6 terminals total). For stationary breakers only. Terminal blocks are rated 10 amperes at 600 Vac. Factory Installed Product Numbers Breaker Envelope Size (Amps) Breaker Terminals 1000, 1600 and List Price 6 TPTB1R,L $ TPTB2R,L $ TRL/TRP 18 TPTBR,L $ R Frame 24 TPTB4L $ TPTB5L $ TPTB6L $ Limited to left side only. Walking Beam Interlock Not UL listed Product Number GO-145A List Price TPWB $ TPK01 (Type F) $ TPK02 (Type M2F) $ TPK0 (Type MF) $ TPK04 (Type M4F) $ Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -105

106 Power Management System Accessories Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units All Devices UL Listed for Factory or Field Installation (UL File No. E-5725) Required Accessories Type Accessories Standard Ground Fault Option with -phase, 4-wire Neutral Current Sensor and Terminal Block MicroVersaTrip Plus Trip Unit or 1-phase, -wire service or Neutral Current Sensor and Junction Box Control Power Option Power Supply Plate or Voltage Module 1 or Power Supply Assembly 2 Power Supply Plate and Voltage Conditioner Plate or Voltage Module 1 Standard or with Protective Relaying or Power Supply Assembly 2 and Voltage Conditioner Assembly 2 MicroVersaTrip PM Trip Unit Junction Box, Cable Harness and Auxiliary Switch Ground Fault Option with -phase, 4-wire Neutral Current Sensor or 1-phase, -wire service 1 For installation into GE Spectra Series Switchboards only. 2 Requires fuse protection and other components; refer to accessory detail for additional information. Power Supply Plate GO-15PM The Power Supply Plate is used to provide +24 Vdc control power to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip PM or MicroVersaTrip Plus trip systems via the Distribution Cable System. The Power Supply Plate includes the Power Supply Assembly (product number SPSAA) as an integral component and also includes fuse protection for AC source input. Supplemental +24 Vdc input terminals are provided for backup control power applications. Five versions are available. Not suitable for 400 Hz. Description Voltage Rating Product Number List Price The Power Supply Plate is rated 24 watts 120 Vac SPSA120 $ (+24 Vdc at 1.0 amperes) and has the maximum 208 Vac SPSA208 $ capacity to power a distribution Cable System 240 Vac SPSA240 $ consisting of 20 breakers and has a maximum 480 Vac SPSA480 $ system cable length of 40 feet. 600 Vac SPSA600 $ Voltage Conditoner Plate GO-15PM The Voltage Conditioner Plate is used to provide voltage sensing signals to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip PM Trip Units via the Distribution Cable System. The Voltage Conditioner Plate includes the Voltage Conditioner Assembly (product number SVCAA) as an integral component and also includes fuse protection for the AC source input terminals and three 1-VA high accuracy potential transformers. The Voltage Conditioner Plate requires a control power source of +24 Vdc to operate properly (the Power Supply Assembly or Power Supply Plate can provide this required input). The unit also requires AC direct voltage inputs from the AC source. A GE POWER LEADER network (commnet) connection is provided. Seven versions are available. Not suitable for 400 Hz. Voltage Rating and Service Type Comments Product Number List Price 120 Vac Wye system Phase to Neutral potential SVCA120Y $ Vac Wye system Phase to Phase potential SVCA208Y $ Vac Delta system Phase to Phase potential SVCA240D $ Vac Wye system Phase to Neutral potential SVCA277Y $ Vac Wye system Phase to Phase potential SVCA480Y $ Vac Delta system Phase to Phase potential SVCA480D $ Vac Delta system Phase to Phase potential SVCA600D $ Note: The Voltage Conditoner Plate has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet. Distribution Cable Junction Box GO-15PM The Distribution Cable Junction Box is a modular connector used to provide quick, easy and reliable attachment of Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus trip systems or MicroVersaTrip PM trip systems to the Distribution Cable System. The Junction Box contains two Distribution Cable Harness plugs, one breaker plug and a terminal block for the connection of a neutral current sensor and an auxiliary switch. Product number SDCJBA is for general purpose OEM applications. Product number SDCJBB is designed for mounting in Spectra Series Panelboards. Description Product Number List Price Distribution Cable Junction Box SDCJBA $ Distribution Cable Junction Box SDCJBB $ Distribution Cable Harness GO-15PM The Distribution Cable Harness is a modular connector used to carry electronic signals and/or control power between Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip PM Trip Units and Distribution Cable accessories. The harnesses come in three lengths. Description Harness Length Product Number List Price Distribution Cable Harness 11 inches SDCHA11 $70.00 Distribution Cable Harness 0 inches SDCHA0 $80.00 Distribution Cable Harness 60 inches SDCHA60 $ Cannot be connected together. Use 0 inch Distribution Cable Extension (SDCEA0) to extend. Power Supply Plate Voltage Conditioner Plate Distribution Cable Junction Box Distribution Cable Harness -106 BuyLog Catalog Rev. 12/04 distributed by AA Electric

107 Power Management System Accessories Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units All Devices UL Listed for Factory or Field Installation (UL File No. E-5725) Required Accessories Distribution Cable Extension GO-15PM The Distribution Cable Extension is used to provide modular expansion of the Distribution Cable System. Description Harness Length Product Number List Price Distribution Cable Extension 0 inches SDCEA0 $80.00 Type Accessories Standard Ground Fault Option with -phase, 4-wire Neutral Current Sensor and Terminal Block MicroVersaTrip Plus Trip Unit or 1-phase, -wire service or Neutral Current Sensor and Junction Box Control Power Option Power Supply Plate or Voltage Module 1 or Power Supply Assembly 2 Power Supply Plate and Voltage Conditioner Plate or Voltage Module 1 Standard or with Protective Relaying or Power Supply Assembly 2 and Voltage Conditioner Assembly 2 MicroVersaTrip PM Trip Unit Junction Box, Cable Harness and Auxiliary Switch Ground Fault Option with -phase, 4-wire Neutral Current Sensor or 1-phase, -wire service 1 For installation into GE Spectra Series Switchboards only. 2 Requires fuse protection and other components; refer to accessory detail for additional information. Distribution Cable Terminal Block GO-15PM The Distribution Cable Terminal Block is a modular attachment primarily used to provide an alternate means of input to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip PM Trip Units. The Terminal Block plugs into the breaker distribution cable receptacle allowing the direct connection of breaker signals via screw terminals. This allows point-to-point wiring of breakers instead of using the Distribution Cable System. Description Product Number List Price Distribution Cable Terminal Block SDCTBA11 $ Distribution Cable Extension Power Supply Assembly GO-15PM The Power Supply Assembly is used to provide +24 Vdc Control Power to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip PM trip systems via the Distribution Cable System. The assembly requires a minimum input voltage of 85 Vac to operate properly (the maximum voltage rating is 240 Vac). Supplemental +24 Vdc input terminals are provided for backup control power applications. The input must be fused with 1/2 ampere class CC fuses (not included). Not suitable for 400 Hz. Description Voltage Rating Product Number List Price The Power Supply Assembly is rated 24 watts Vac SPSAA $ ( ampere) and has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet. Voltage Conditioner Assembly GO-15PM The Voltage Conditioner Assembly is used to provide voltage sensing signals to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip PM Trip Units via the Distribution Cable System. The Voltage Conditioner Assembly requires a control power source of +24 Vdc to operate properly (the Power Supply Assembly or Power Supply Plate can provide this required input). The unit also requires 120 Vac voltage inputs from the secondary of three 1- VA high accuracy potential transformers (not included). The primary side of the potential transformers must be fused with three, 1/2 ampere class CC fuses (not included). A GE POWER LEADER network (commnet) connection is provided. Not suitable for 400 Hz. Description Voltage Rating Product Number List Price Requires 120 Vac voltage inputs from the 120 Vac SVCAA $ secondary of three 1.0 VA high accuracy potential transformers Note: the Voltage Conditioner Assembly has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet. Distribution Cable Terminal Block Power Supply Assembly Voltage Conditioner Assembly Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Rev. 12/04 BuyLog Catalog -107

108 Power Management System Accessories Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units All Devices UL Listed for Factory or Field Installation (UL File No. E-5725) Voltage Modules GO-15PM The Voltage Module is used primarily as a Spectra Series Switchboard component to provide +24 Vdc Control Power to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip PM Trip Units via the Distribution Cable System. The Module also provides voltage sensing signals to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip PM Trip Units on the same Distribution Cable System. The Module contains both a Power Supply Plate and a Voltage Conditioner as integral components. It also includes fuse protection for the AC source input terminals (the modules pressure connectors which mate with the switchboard interior bus bars). A GE POWER LEADER Network (commnet) connection is provided as well as supplemental 24 Vdc input terminals for backup control power applications. Seven versions are available. Not suitable for 400 Hz. Voltage Rating and Service Type Comments Product Number List Price 120 Vac Wye system Phase to Neutral potential ADSVMA120Y $ Vac Wye system Phase to Phase potential ADSVMA208Y $ Vac Delta system Phase to Phase potential ADSVMA240D $ Vac Wye system Phase to Neutral potential ADSVMA277Y $ Vac Wye system Phase to Phase potential ADSVMA480Y $ Vac Delta system Phase to Phase potential ADSVMA480D $ Vac Delta system Phase to Phase potential ADSVMA600D $ Note: The Voltage Module has the maximum capacity to power a Distribution Cable System consisting of 20 breakers and has a maximum system cable length of 40 feet. Voltage Module Exterior View Voltage Module Interior View distributed by AA Electric BuyLog Catalog Rev. 12/04

Section 3. Molded Case Circuit Breakers.

Section 3. Molded Case Circuit Breakers. Molded Case Circuit Breakers Section 3 Industrial Circuit Breakers How to Order...3-2 Features...3-4 Quick Reference Guide...3-5 Q-Line Circuit Breakers Plug-In 120/240V Class...3-11 Plug-In 240V Class...3-13

More information

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

THQL1120AF2 THQL1120AF2 Arc Fault BRKR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

Molded Case Circuit Breakers Section 3 Q-Line Circuit Breakers

Molded Case Circuit Breakers Section 3 Q-Line Circuit Breakers Molded Case Circuit Breakers Section 3 QLine Circuit Breakers Cablein Cableout (luglug) 240V Class TQD 240 Vac, Internal Common Trip # of Ampere 240 Vac Price Poles Rating Interrupting Rating Product Number

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

Section 6. Molded Case Circuit Breakers. BuyLog Catalog 6-1. Section Updated 03 / 2014

Section 6. Molded Case Circuit Breakers.   BuyLog Catalog 6-1. Section Updated 03 / 2014 Molded Case Circuit Breakers Section Updated 0 / 014 Section 6 Industrial Circuit Breakers How to Order...6- Features...6-4 Quick Reference Guide...6-6 Q-Line Circuit Breakers Plug-In 10/40V Class...6-14

More information

Molded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1

Molded Case Circuit Breakers. Section 6.  BuyLog Catalog 6-1 Molded Case Circuit Breakers Section 6 Industrial Circuit Breakers How to Order...6-2 Features...6-4 Quick Reference Guide...6-6 Q-Line Circuit Breakers Plug-In 120/240V Class...6-14 Plug-In 240V Class...6-16

More information

Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

Section 1. Load Centers and Circuit Breakers.  Section Updated 11 / 2014 Section Updated 11 / 2014 Q-Line Circuit Breakers Product Features and Benefits...1-2 PowerMark Gold Load Centers Product Features and Benefits...1-3 PowerMark Gold and Plus Load Centers Product Number

More information

Molded Case Circuit Breakers Section 6 Q-Line Circuit Breakers

Molded Case Circuit Breakers Section 6 Q-Line Circuit Breakers Q-Line Circuit Breakers Accessories 240V Class Terminals (Lugs) for Q-Line Circuit Breakers Ampere Rating Termination Type Wire Range (Cu/Al) Product Number 15-60 Lug (line only) 14-6/12-2 TQAL3A 15-60

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Molded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1

Molded Case Circuit Breakers. Section 6.  BuyLog Catalog 6-1 GuardEon Circuit Breakers Overview...6-2 Industrial Circuit Breakers How to Order...6-4 Features...6-6 Quick Reference Guide... 6-8 Q-Line Circuit Breakers Plug-In 120/240V Class...6-16 Plug-In 240V Class...

More information

Residential. Section 1.

Residential. Section 1. Load enters Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in ircuit reakers...1-5

More information

Molded Case Circuit Breakers Industrial Circuit Breakers A Thermal Magnetic Trip. Section 3. BuyLog Catalog 3-29

Molded Case Circuit Breakers Industrial Circuit Breakers A Thermal Magnetic Trip. Section 3.  BuyLog Catalog 3-29 Molded Case Circuit Breakers 15-100A Thermal Magnetic Trip Type TEY/TEYF Noninterchangeable Trip Bolt-on 480Y/277V Class Section 3 Page Updated 09 / 2011 TEY and TEYF breakers are one-inch wide per pole,

More information

Power Break II Switchboard

Power Break II Switchboard Power Break II Switchboard Now available with PowerBreak II Circuit Breakers through 4000A GE s Power Break II Switchboard is now available with the new Power Break II Insulated Case Circuit Breaker (800A

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers GE Consumer & Industrial Electrical Distribution Power Break II Insulated Case Circuit Breakers Table of Contents Power Break II Circuit Breakers......................... 3 Basic Configuration.......................................

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G . NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes 12- Product Selection Table 12-33. s, H, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous

More information

VL Circuit Breaker DG 150A frame

VL Circuit Breaker DG 150A frame VL Circuit Breaker DG 150A frame Breaker type Defined by the 3rd character of the catalog number G Global (UL, CSA, IEC, CE, CCC), interchangeable K Global, non-interchangeable W Global, 100% rated, non-interchangeable,

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable Trip unit type Defined by the 5th character of the catalog number B Thermal-magnetic,

More information

GE Energy Industrial Solutions. Aftermarket Catalog. imagination at work

GE Energy Industrial Solutions. Aftermarket Catalog. imagination at work GE Energy Industrial Solutions Aftermarket Catalog imagination at work Aftermarket Catalog Quick Section Index Aftermarket Catalog Table of Contents 1 Components: Parts 2 Switchgear 3 Motor Control Centers

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Selection This information is presented only as an aid to understanding catalog numbers.

More information

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M MS50T3L M2N200T3L na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units GE Energy Industrial Solutions GEH-6255 Installation Instructions Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless

More information

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric. Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches MS50T3L M2N200T3L Ex9 Series - M na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Section 7. Circuit Breaker Enclosures. BuyLog Catalog 7-1

Section 7. Circuit Breaker Enclosures.  BuyLog Catalog 7-1 NEMA Type 1 Enclosures... 7-2 NEMA Type 3R Enclosures...7-3 NEMA Type 12 Enclosures...7-4 NEMA Type 4/4X Enclosures... 7-5 Hubs and Other Accessories... 7-6 Dimensions and Outline Drawings...7-7 Dimensions

More information

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage Switchgear Low Voltage Introduction...13-1 AKD-10 Low-Voltage Switchgear...13-3 AKD-20 Low-Voltage Switchgear...13-3 Low Voltage Switchgear GE low-voltage switchgear is heavy-duty equipment built to ANSI

More information

Type MP-T Type MP-HT Type MP-MT

Type MP-T Type MP-HT Type MP-MT CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List

More information

Circuit Breaker Enclosures Section 7 NEMA Type 1

Circuit Breaker Enclosures Section 7 NEMA Type 1 NEMA Type 1 Type 1, Indoor Surface or Flush Mounting NEMA Type 1 THQL, TXQL, THQL-GF 1, 2, 3 70 TQL70F 3 Included TQL70S 3 Included 1, 2, 3 100 TQL100F 3 Included TQL100S 3 Included THQC, THHQC, TXQC 1,

More information

www. ElectricalPartManuals. com Time Current Curves and Outline Drawings Time Current Curves Molded Case Circuit Breakers and Motor Circuit Protectors

www. ElectricalPartManuals. com Time Current Curves and Outline Drawings Time Current Curves Molded Case Circuit Breakers and Motor Circuit Protectors Molded Case Circuit Breakers and Motor Circuit Protectors Q-Line THQL AF (15 Amp)...DES-011 THQL AF (20 Amp)...DES-012 THQL GF, THHQL GF (15 Amp) 1...GES-9881 THQL GF, THHQL GF (20 Amp) 1...GES-9882 THQL

More information

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs. SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

Circuit Breaker Enclosures. Section 4.

Circuit Breaker Enclosures. Section 4. Circuit Breaker Enclosures Section 4 NEMA Type 1 Enclosures...4-2 NEMA Type 3R Enclosures...4-3 NEMA Type 12 Enclosures...4-4 NEMA Type 4/4X Enclosures...4-5 Hubs and Other Accessories...4-6 Dimensions

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

Evolution Series Switchboards

Evolution Series Switchboards GE Energy Evolution Series Switchboards Quick Reference imagination at work Main Lug Main Device Width (W) Switchboard Frame Neutral Bus Width (W) Switchboard Frame Neutral Bus Cover 3 A Ground Bar 10

More information

Modifications. Marine 50 C Ambient Calibration

Modifications. Marine 50 C Ambient Calibration 1-Pole Bolt-On (120V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 15 B115 B115H B115HH 20 B120 B120H B120HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH

More information

IN2 Enclosed Switches and Circuit Breakers

IN2 Enclosed Switches and Circuit Breakers Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7 EP60 Series...7-2 EP100 Series...7-4 EP100 ULH Series...7-6 EP100 UC Series (Branch Circuit Protection)...7-8 Series CA Auxiliary Switch and Bell Alarm...7-10 Series CB Auxiliary Switch and Bell Alarm...7-11

More information

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1 GE 8000-Line -1 Mains, coming Lines MAINS GENERAL Main units consist of an externally operable circuit disconnect, either a fusible switch or a circuit breaker. Sizes by ampere rating, short-circuit rating,

More information

Section 4: Circuit Breaker Enclosures

Section 4: Circuit Breaker Enclosures Section : NEMA Type 1 Enclosures...-2 NEMA Type 3R Enclosures...-3 NEMA Type 12 Enclosures...- NEMA Type /X Enclosures...-5 Hubs and Other Accessories...-6 Dimensions and Outline Drawings...-7 Dimensions

More information

30 ma Ground Fault (Earth Leakage) Modules. Product Description

30 ma Ground Fault (Earth Leakage) Modules. Product Description August 2006 0 ma Ground Fault (Earth Leakage) Modules 5-0 ma Ground Fault (Earth Leakage) Modules Clockwise from Left:,, MCCBs Shown with Ground Fault (Earth Leakage) Modules Product Description Eaton

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers SMD 800A Frame Digital Solid State Sentron Sensitrip III Series Selection Type SMD6 Type SHMD6 Current Limiting Type SCMD6 Blue Label Black Label Red Label Catalog Current List SMD69600A 600 SMD69700A

More information

Modifications. Marine 50 C Ambient Calibration

Modifications. Marine 50 C Ambient Calibration 1-Pole Bolt-On (1V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 B1 B1H B1HH B1 B1H B1HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH 40 B140 B140H B140HH

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

GEH-6259 Installation Instructions Voltage Conditioner Assembly

GEH-6259 Installation Instructions Voltage Conditioner Assembly GE Industrial Solutions GEH-6259 Installation Instructions Voltage Conditioner Assembly For use with microentelliguard*, EntelliGuard TU, MicroVersaTrip* PM or MicroVersaTrip* Plus Trip Units For Catalog

More information

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600 January 01 Vol. 1, Ref. No. [05] 1 Amperes 12- Table 12-99. Type Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Maximum Continuous Ampere 2-Pole 0 0 3-Pole 0 0 V AC Rated, 0V DC

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

SIEMENS. Microprocessor-Based Tripping System. Static lrip III. www. ElectricalPartManuals. com

SIEMENS. Microprocessor-Based Tripping System. Static lrip III. www. ElectricalPartManuals. com SIEMENS Microprocessor-Based Tripping System Static lrip III A Revolutionary Advance In Equipment Protection. Siemens. a pioneer in electronics technology, now provides the highest level of equipment monitoring

More information

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features S200 UL 489 Series Miniature S200 UL 489 Series Miniature Circuit Breakers Description The S200 Series miniature circuit breaker offers a compact solution for protection requirements. The S200U AND S200UP

More information

UBW Family UL489 Molded Case Circuit Breakers

UBW Family UL489 Molded Case Circuit Breakers UBW Family UL489 Molded Case Circuit Breakers The UBW line offers the quality, realiablity and uncompromising protection that you have come to expect from WEG Molded Case Circuit Breakers UBW Series Product

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers Specification Guide for RMAX Direct Replacement AC Low Voltage Power Circuit Breakers Table of Contents 1.0 General Work Scope...3 2.0 Standards... 3 3.0 Supplier Qualifications... 3 4.0 Mechanical and

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Type SND6 Molded Case Circuit Breakers SND 1200A Frame Digital Solid State Sentron Sensitrip III Series Type SHND6 Current Limiting Type SCND6 Blue Label Black Label Red Label Catalog Current Price SND69800A

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

2.3. Molded Case Circuit Breakers. Contents

2.3. Molded Case Circuit Breakers. Contents .3 Molded Case Circuit Breaker Product Family Product Overview Eaton s molded case circuit breakers are designed to provide circuit protection for low voltage distribution systems. They are described by

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information