Power Mod. Type WMM Residential Meter Stacks. Revised 06/01/13. Residential Meter Stacks

Size: px
Start display at page:

Download "Power Mod. Type WMM Residential Meter Stacks. Revised 06/01/13. Residential Meter Stacks"

Transcription

1 Type WMM Residential Meter Stacks 06/01/13 Residential Meter Stacks Power Mod s core offering of Residential Meter Stacks, type WMM, offers the widest product offering and flexibility in the industry. Each meter stack houses the QuickSystem features to maximize productivity and minimize labor costs. To aid in productivity and labor cost reductions our 5 Amp meter stacks feature a new breaker - the QS. The QS breaker adds to the Siemens exclusive feature set on our new 5 Amp Residential Meter Stacks. Benefits of the QS include: J An exclusive 6 high 5 Amp meter stack at the same height as our 15 Amp meter stack - 5 to 15 conversion: No conversion kit needed. J Single right hand bend wiring - saves time and wire J 100K AIC offered from 100 up to 5 Amps Siemens Residential Meter Stacks are packed with features inside and out: our exclusive knock out plate offers flexibility when pulling wires to the stack, new breaker supports keep breakers level and straight, moveable neutrals and grounds to save wire, and all of the QuickSystem features all designed with the contractor in mind. Residential Meter Stacks quick reference Metering WMM n -6 gang n 15/5 Amp per position n 100 Amp thru-bus rating n UL standard 67 n UL file no. E7100 n AIC rating (65k & 100k) n Voltage: Single phase 10/40V AC max. Three phase in single phase out 10/08V AC max. 40/10V AC max. n All swing latches and rivets are stainless steel. n = NEMA 3R rated n = NEMA 1R rated n G90 galvanized steel n ANSI 61 paint n Custom options available! Details on page Siemens Industry, Inc. SPEEDFAX 011 Product Catalog

2 Type WMM Residential Meter Stacks 1 phase 4J 0/18/14 n -6 gang n 15/5 Amp per position n 100 Amp thru-bus rating Residential 4-jaw ring type meter stacks: 1-phase, 3-wire SN, incoming and outgoing c Meter positions Max. tenant breaker (Amps): 15 WMM115 MM115 Position provision Maximum AIC e Dimensions (inches) a Height Width Depth Knockout diagram 65k KA-1 WMM3115 MM Position QP, QPH, 65k KA-13 WMM4115 MM Position HQP, MP-T, MP-HT, 65k KA-14 WMM5115 MM Position MP-MT 65k KA-15 WMM6115 MM Position 65k KA-16 Max. tenant breaker (Amps): 5 b f WMM15 MM15 Position 100k KA- WMM315 MM315 3 Position QS, QSH, QSHH, 100k KA-3 WMM415 MM415 4 Position HQS, HQSH, QP, QPH, HQP, MP-T, 100k KA-4 WMM515 MM515 5 Position MP-HT, MP-MT 100k KA-5 WMM615 MM615 6 Position 100k KA-6 Residential 4-jaw ringless type meter stacks: 1-phase, 3-wire SN, incoming and outgoing c (no bypass) (horn bypass) Max. tenant breaker (Amps): 15 (no bypass) (horn bypass) Meter positions WMM115R WMM115RB MM115R MM115RB Position provision Max. AIC e Dimensions (inches) a Height Width Depth Knockout diagram 65k KA-1 Metering WMM WMM3115R WMM4115R WMM5115R WMM3115RB WMM4115RB WMM5115RB MM3115R MM4115R MM5115R MM3115RB MM4115RB MM5115RB 3 Position 4 Position 5 Position QP, QPH, HQP, MP-T, MP-HT, MP-MT 65k 65k 65k KA-13 KA-14 KA-15 WMM6115R WMM6115RB MM6115R MM6115RB 6 Position 65k KA-16 Max. tenant breaker (Amps): 5 WMM15R WMM15RB MM15R MM15RB Position 100k KA- QS, QSH, WMM315R WMM315RB MM315R MM315RB 3 Position QSHH, HQS, 100k KA-3 HQSH, QP, WMM415R WMM415RB MM415R MM415RB 4 Position QPH, HQP, 100k KA-4 MP-T, WMM515R WMM515RB MM515R MM515RB 5 Position MP-HT, 100k KA-5 MP-MT WMM615R WMM615RB MM615R MM615RB 6 Position 100k KA-6 a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, endwalls, covers, hubs, or hardware protrusions. Dimensions are subject to change. b 5A available in lower three positions only. 00A continuous for all other positions. c NOT for use on 3-phase, 4-wire delta systems. d Field installed 5th jaw ECMF5. 5th jaw can be isolated if needed. e Max AIC determined by maximum AIC of tenant breakers. Higher ratings may be achieved through approved series rating combinations. f Install QP breakers below QS breakers. Siemens Industry, Inc. SPEEDFAX 011 Product Catalog -99

3 Type WMM Residential Meter Stacks 1 phase 5J 0/18/14 n -6 gang n 15/5 Amp per position n 100 Amp thru-bus rating Residential 5-jaw ring type meter stacks: 1-phase, 3-wire SN, incoming and outgoing cd Meter positions Max. tenant breaker (Amps): 15 WMM115J MM115J Position provision Maximum AIC e Dimensions (inches) a Height Width Depth Knockout diagram 65k KA-1 WMM3115J MM3115J 3 Position QP, QPH, HQP, 65k KA-13 WMM4115J MM4115J 4 Position MP-T, MP-HT, 65k KA-14 WMM5115J MM5115J 5 Position MP-MT 65k KA-15 WMM6115J MM6115J 6 Position 65k KA-16 Max. tenant breaker (Amps): 5 WMM15J MM15J Position 100k KA- WMM315J MM315J 3 Position QS, QSH, QSHH, 100k KA-3 WMM415J MM415J 4 Position HQS, HQSH, QP, QPH, HQP, MP-T, 100k KA-4 WMM515J MM515J 5 Position MP-HT, MP-MT 100k KA-5 WMM615J MM615J 6 Position 100k KA-6 Metering WMM Residential 5-jaw ringless type meter stacks: 1-phase, 3-wire SN, incoming and outgoing c d (no bypass) (horn bypass) Max. tenant breaker (Amps): 15 (no bypass) (horn bypass) Meter positions WMM115RJ WMM115RJB MM115RJ MM115RJB Position provision Max. AIC e Dimensions (inches) a Height Width Depth Knockout diagram 65k KA-1 WMM3115RJ WMM4115RJ WMM5115RJ WMM3115RJB WMM4115RJB WMM5115RJB MM3115RJ MM4115RJ MM5115RJ MM3115RJB MM4115RJB MM5115RJB 3 Position 4 Position 5 Position QP, QPH, HQP, MP-T, MP-HT, MP-MT 65k 65k 65k KA-13 KA-14 KA-15 WMM6115RJ WMM6115RJB MM6115RJ MM6115RJB 6 Position 65k KA-16 Max. tenant breaker (Amps): 5 WMM15RJ WMM15RJB MM15RJ MM15RJB Position 100k KA- QS, QSH, WMM315RJ WMM315RJB MM315RJ MM315RJB 3 Position QSHH, HQS, 100k KA-3 HQSH, QP, WMM415RJ WMM415RJB MM415RJ MM415RJB 4 Position QPH, HQP, 100k KA-4 MP-T, WMM515RJ WMM515RJB MM515RJ MM515RJB 5 Position MP-HT, 100k KA-5 MP-MT WMM615RJ WMM615RJB MM615RJ MM615RJB 6 Position 100k KA-6 a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, endwalls, covers, hubs, or hardware protrusions. Dimensions are subject to change. b 5A available in lower three positions only. 00A continuous for all other positions. c NOT for use on 3-phase, 4-wire delta systems. d Field installed 5th jaw ECMF5. 5th jaw can be isolated if needed. e Max AIC determined by maximum AIC of tenant breakers. Higher ratings may be achieved through approved series rating combinations. f Install QP breakers below QS breakers Siemens Industry, Inc. SPEEDFAX 011 Product Catalog

4 Type WMM Residential Meter Stacks 3 phase in 1 phase out 5J 0/18/14 n -6 gang n 15/5 Amp per position n 100 Amp thru-bus rating Residential 5-jaw ring type meter stacks: 3-phase, 4-wire SN, incoming and 1-phase, 3 wire SN outgoing cdg Max. tenant breaker (Amps): 15 Meter positions WMM15J MM15J Position provision Maximum Dimensions (inches) a Knockout AIC e Height Width Depth diagram 65k KA-1 WMM315J MM315J 3 Position 65k KA-13 WMM415J MM415J 4 Position QP, QPH, HQP, MP-T, MP-HT, MP-MT 65k KA-14 WMM515J MM515J 5 Position 65k KA-15 WMM615J MM615J 6 Position 65k KA-16 Max. tenant breaker (Amps): 5 WMM5J MM5J Position 100k KA- WMM35J MM35J 3 Position QS, QSH, QSHH, HQS, 100k KA-3 WMM45J MM45J 4 Position HQSH, QP,QPH, HQP, MP-T, 100k KA-4 WMM55J MM55J 5 Position MP-HT, MP-MT 100k KA-5 WMM65J MM65J 6 Position 100k KA-6 Residential 5-jaw ringless type meter stacks: 3-phase, 4-wire SN, incoming and 1-phase, 3 wire SN outgoing cdg (no bypass) (horn Bypass) Max. tenant breaker (Amps): 15 (no bypass) (horn bypass) Meter positions WMM15RJ WMM15RJB MM15RJ MM15RJB Position provision Max. AIC e Dimensions (inches) a Height Width Depth Knockout diagram 65k KA-1 Metering WMM WMM315RJ WMM415RJ WMM515RJ WMM315RJB WMM415RJB WMM515RJB MM315RJ MM415RJ MM515RJ MM315RJB MM415RJB MM515RJB 3 Position 4 Position 5 Position QP, QPH, HQP, MP-T, MP-HT, MP-MT 65k 65k 65k KA-13 KA-14 KA-15 WMM615RJ WMM615RJB MM615RJ MM615RJB 6 Position 65k KA-16 Max. tenant breaker (Amps): 5 WMM5RJ WMM5RJB MM5RJ MM5RJB Position 100k KA- WMM35RJ WMM35RJB MM35RJ MM35RJB 3 Position QS, QSH, QSHH, HQS, 100k KA-3 WMM45RJ WMM45RJB MM45RJ MM45RJB 4 Position HQSH, QP, QPH, HQP, 100k KA-4 WMM55RJ WMM55RJB MM55RJ MM55RJB 5 Position MP-T, MP-HT, MP-MT 100k KA-5 WMM65RJ WMM65RJB MM65RJ MM65RJB 6 Position 100k KA-6 a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, endwalls, covers, hubs, or hardware protrusions. Dimensions are subject to change. b 5A available in lower three positions only. 00A continuous for all other positions. c Approved for use on 3-phase, 4-wire delta systems. Must field phase away from B phase (A & C phase only). d 5th jaw can be isolated if needed. e Max AIC determined by maximum AIC of tenant breakers. Higher ratings may be achieved through approved series rating combinations. f Install QP breakers below QS breakers. g Stacks come factory phased as AB, BC, AC... top to bottom Siemens Industry, Inc. SPEEDFAX 011 Product Catalog -101

5 Type WMM Residential Meter Stacks: Knockout Diagrams 0/18/ /16 7" TO QUICK ROLL BRACKET 36" TO QUICK ROLL BRACKET 43-5/ /8 TO -7/16 1-5/8 1-5/3 (6) KOs 1, 1-1/4, 1-1/, " 4-3/8 TO 1-5/3 36" TO QUICK ROLL BRACKET 4-3/8 TO 5-5/16 WMM115XX WMM15XXX 1-31/3 KA-1 MM115XX MM15XXX -7/16 1-5/8 1-31/3 KA-13 (6) KOs 1, 1-1/4, 1-1/, " -7/16 1-5/8 1-5/3 (6) KOs 1, 1-1/4, 1-1/, " WMM3115XX MM3115XX 1-31/3 WMM315XXX MM315XXX KA-14 WMM4115XX MM4115XX 13-3/3 WMM415XXX MM415XXX 3-1/ /3 3-1/ 1-15/16 3-1/4 8-3/3 15 Amp Typical Top View for NEMA 1 Metering WMM 13-3/3 8-3/3 8-3/3 15 Amp Typical Top View 36" TO QUICK ROLL BRACKET 61-5/ /16 3-1/4-9/3 (6) KOs 1, 1-1/4, 1-1/, " 15 Amp Typical Bottom View 4-3/8 TO -7/16 1-5/8 WMM5115XX WMM515XXX 1-31/3 KA-15 KA /3 MM5115XX MM515XXX (6) KOs 1, 1-1/4, 1-1/, 36" TO QUICK ROLL BRACKET 4-3/8 TO -7/16 1-5/8 WMM6115XX WMM615XXX 1-31/3 KA /3 (6) KOs 1, 1-1/4, 1-1/, " MM6115XX MM615XXX -10 Siemens Industry, Inc. SPEEDFAX 011 Product Catalog

6 Type WMM Residential Meter Stacks: Knockout Diagrams 0/18/14 L -3/8 TO SS BUS ENTER -7/16 1-5/8 7" TO QUICK ROLL BRACKET 36" TO 43-5/16 QUICK ROLL 5-5/16 BRACKET34-5/ /8 TO 4-3/8 TO 1-5/3 1-5/3 4-3/8 TO 1-5/3-7/16 (6) KOs 1, 1-1/4, 1-1/, " 1-5/8 16-3/3 16-3/3 16-7/3 KA- WMM15XX WMM5XXX 8-3/3 (6) KOs 1, 1-1/4, 1-1/, " MM15XX MM5XXX 36" TO TTOM OF ICK ROLL RACKET -7/16 1-5/8 16-3/3-7/16 1-5/8 WMM315XX WMM35XXX (6) KOs 1, 1-1/4, 1-1/, " 16-3/3 KA-3 1-5/3 43-5/16 (6) KOs 1, 1-1/4, 1-1/, " MM315XX MM35XXX 36" TO QUICK ROLL BRACKET 4-3/8 TO -7/16 1-5/8 WMM415XX WMM45XXX 16-3/3 KA-4 1-5/3 MM415XX MM45XXX 5-5/16 (6) KOs 1, 1-1/4, 1-1/, " 4" " -3/3 16-7/3-3/16 3-1/4 8-1/3 5 Amp Typical Top View for NEMA /3 36" TO QUICK ROLL BRACKET 61-5/ /16 Metering WMM 8-3/3 5 Amp Typical Top View 4" " -3/16 3-1/4-9/3 (6) KOs 1-1/,, -1/" 5 Amp Typical Bottom View 4-3/8 TO -7/16 1-5/8 WMM515XX WMM55XXX 16-3/3 KA-5 1-5/3 MM515XX MM55XXX (6) KOs 1, 1-1/4, 1-1/, " 36" TO QUICK ROLL BRACKET 4-3/8 TO -7/16 1-5/8 WMM615XX WMM65XXX 16-3/3 KA-6 1-5/3 (6) KOs 1, 1-1/4, 1-1/, " MM615XX MM65XXX Siemens Industry, Inc. SPEEDFAX 011 Product Catalog -103

7 Type WML Lever Bypass Meter Stacks 06/01/13 Lever Bypass Meter Stacks Commercial Lever Bypass meter stacks (type WML) are designed to meet the requirements of those utilities specifying lever bypass meter sockets for residential and commercial applications. Features include: n QuickSystem features n High-quality, time-proven Talon HQ sockets n A line of 3-phase 100 Amp meter stacks to minimize tenant main cost n Removable back knockout plate to facilitate wiring n 5 Amp capability in single and three phase designs n Up to 4 positions with 5 Amp tenant mains, up to positions with 400 Amp tenant mains n Ease of wiring tenant mains require only a single bend Lever Bypass quick reference Metering WML n 100A/5A 1-4 position n 400A 1- position n 100A thru-bus rating n UL Standard # UL67 n UL file # E7100 n AIC rating (5K, 65K & 100K) n Voltage Single phase 10/40V AC max Three in single phase out 08Y/10V AC Three Phase 40V AC max n All swing latches and rivets are stainless steel. n = NEMA 3R rated n = NEMA 1R rated n G90 Galvanized Steel n ANSI 61 Paint n Custom options available! Details on page Siemens Industry, Inc. SPEEDFAX 011 Product Catalog

8 Type WML Lever Bypass Meter Stacks 0/18/14 n 5A 1-4 position n 400A 1- position n 100A thru-bus rating Commercial ringless type meter stacks: Lever Bypass Meter positions Dimensions (inches)a Provisions Maximum AIC c Height Width Depth Stack phasing phases/sockets 1-phase, 3-wire SN, incoming and outgoing, lever bypass, 5-jaw sockets b Max. tenant breaker (Amps): 5 WML115RJ ML115RJ 1 100k L-1 WML15RJ ML15RJ QS, QSH, QSHH, HQS, 100k L- HQSH, QP, QPH, HQP, WML315RJ ML315RJ 3 MP-T, MP-HT, MP-MT 100k L-3 WML415RJ ML415RJ 4 100k L-4 Max. tenant breaker (Amps): 400 WML11400RJ d ML11400RJ d 1 JXD6B400 Factory inst 5k L-5 WML1400RJ d ML1400RJ d 5k L-6 3-phase, 4-wire SN, incoming and 1-phase, 3-wire SN outgoing, lever bypass, 5-jaw sockets b e Max. tenant breaker (Amps): 5 WML15RJ ML15RJ 1 100k AB L-1 WMLAB5RJ MLAB5RJ 100k AC, 1-BC WMLBC5RJ MLBC5RJ 100k AC, 1-AB L- WMLCA5RJ MLCA5RJ QS, QSH, QSHH, HQS, 100k AB, 1-BC HQSH, QP, QPH, HQP, WML35RL ML35RL 3 MP-T, MP-HT, MP-MT 100k AB, 1-BC, 1-CA L-3 WML4AB5RJ ML4AB5RJ 4 100k AB, 1-BC, 1-CA WML4BC5RJ ML4BC5RJ 4 100k AB, -BC, 1-CA L-4 WML4CA5RJ ML4CA5RJ 4 100k AB, 1-BC, -CA Max. tenant breaker (Amps): 400 WML1400RJ d ML1400RJ d 1 JXD6B400 5k AB L-5 WML400RJ d ML400RJ d Factory Inst 5k AB, 1-BC L-6 Knockout diagram Metering WML Alternate amperage breakers Ad Suffix 1 Meter Position Per Stack T1 T T3 T4 T19 Amperage 00A 50A 300A 350A 5A Ad Suffix Meter Position Per Stack T5 T6 T7 T8 T9 T10 T11 T1 T13 T14 T15 T16 T17 T18 T0 T1 T T3 T4 T5 Amperage 00A/00A 00A/50A 00A/300A 00A/350A 00A/400A 50A/300A 50A/350A 50A/400A 300A/300A 300A/350A 300A/400A 350A/350A 350A/400A 50A/50A 00A/5A 5A/5A 5A/50A 5A/300A 5A/350A 5A/400A a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions. b Not for use on 3-phase, 4-wire delta systems. Max AIC determined by maximum AIC of tenant breakers when used in conjuntion with a meter socket. Higher overall ratings may be achieved through approved series rating combinations. d Alternate amperage breakers are available. Please see table on right for suffix that needs to be added. Additional lead time may apply. Contact sales office for details. e Commerical Stacks are not field phaseable. Siemens Industry, Inc. SPEEDFAX 011 Product Catalog -105

9 Type WML Lever Bypass Meter Stacks 06/01/13 n 100A/5A 1-4 position n 400A 1- position n 100A thru-bus rating Commercial ringless type meter stacks: Lever Bypass Metering WML Meter positions Maximum Dimensions (inches) a Knockout provisions AIC c Height Width Depth diagram 3-phase, 4-wire SN, incoming and outgoing, lever bypass, 7-jaw sockets e Max. tenant breaker (Amps) c : 100 WML13100RJ b ML13100RJ b 1 65k L-7 WML3100RJ b ML3100RJ b QP, MP-T, QPH, MP-HT, 65k L-8 WML33100RJ b ML33100RJ b 3 HQP, MP-MT 65k L-9 WML43100RJ b ML43100RJ b 4 65k L-10 Max. tenant breaker (Amps) c : 5 WML135RJ ML135RJ 1 100k L-11 WML35RJ ML35RJ QJ, QJH, 100k L-1 WML335RJ ML335RJ 3 QJH,MQ, MQH,MQL 100k L-13 WML435RJ ML435RJ 4 100k L-14 Max. tenant breaker (Amps) c : 400 WML13400RJ d ML13400RJ d 1 JXD63B400 5k L-5 WML3400RJ d ML3400RJ d Factory Inst 5k L-6 Alternate amperage breakers Ad Suffix 1 Meter Position Per Stack T1 T T3 T4 T19 Amperage 00A 50A 300A 350A 5A Ad Suffix Meter Position Per Stack T5 T6 T7 T8 T9 T10 T11 T1 T13 T14 T15 T16 T17 T18 T0 T1 T T3 T4 T5 Amperage 00A/00A 00A/50A 00A/300A 00A/350A 00A/400A 50A/300A 50A/350A 50A/400A 300A/300A 300A/350A 300A/400A 350A/350A 350A/400A 50A/50A 00A/5A 5A/5A 5A/50A 5A/300A 5A/350A 5A/400A a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions. b 3-pole breakers only. c Max AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. Higher overall ratings may be achieved through approved series rating combinations. d Alternate amperage breakers are available. Please see below table for suffix that needs to be added. Additional lead time may apply. Contact sales office for details. Rated for use with 40/10V Delta systems Siemens Industry, Inc. SPEEDFAX 011 Product Catalog

10 0/18/14 Power Mod Meter Stacks: WML Lever Bypass Stacks Knockout Diagrams Typical top view for NEMA 1 L-1 WML115RJ ML115RJ WML15RJ ML15RJ L-4 WML415RJ ML415RJ WML4AB5RJ ML4AB5RJ WML4BC5RJ ML4BC5RJ WML4CA5RJ ML4CA5RJ L- ML15RJ WMLAB5RJ MLAB5RJ WMLBC5RJ MLBC5RJ WMLCA5RJ MLCA5RJ Metering WML Metering WML15RJ L-5 WML11400RJ ML11400RJ WML1400RJ ML1400RJ WML13400RJ ML13400RJ L-3 L-6 WML315RJ ML315RJ WML35RJ ML35RJ WML1400RJ ML1400RJ WML400RJ ML400RJ WML3400RJ ML3400RJ Siemens Industry, Inc. SPEEDFAX 011 Product Catalog -107

11 Meter Stacks: WML Lever Bypass Stacks Knockout Diagrams 0/18/14 Metering WML L-7 L-8 WML13100RJ ML13100RJ WML3100RJ ML3100RJ L-9 L-10 WML33100RJ ML33100RJ WML43100RJ ML43100RJ -108 Siemens Industry, Inc. SPEEDFAX 011 Product Catalog

12 0/18/14 Power Mod Meter Stacks: WML Lever Bypass Stacks Knockout Diagrams L-11 WML135RJ ML135RJ L-1 WML35RJ ML35RJ Typical top view for NEMA 1 L-13 WML335RJ ML335RJ L-14 WML435RJ ML435RJ Metering WML Metering Siemens Industry, Inc. SPEEDFAX 011 Product Catalog -109

13 Type WMT Test Block Bypass Meter Stacks 0/18/14 Test Block Bypass Meter Stacks Commercial Test Block Bypass Meter Stacks (type WMT) are designed to meet the requirements of those utilities specifying test block bypass meter sockets for commercial applications in areas subscribing to the EUSERC standards. Features include: n QuickSystem features n High-quality, time-proven Siemens SMM switchboard meter socket n Removable back knockout plate to facilitate wiring n 5 Amp capability in single and three phase designs n Up to 3 positions with 5 Amp tenant mains n Wiring flexibility - tenant mains require only a single bend n Three phase input, single phase output modules n In line wiring: side knockouts allow wiring for adjacent units to pass through Test Block Bypass Quick Reference Metering WMT n 5A 1-3 positions n 100A thru-bus rating n UL Standard #'s UL67 n UL file # E7100 n AIC rating (100K) n Voltage 1 phase 10/40V AC Max 3 phase in 1 phase out 10Y/08V AC Max 3 phase 40V AC Max n All swing latches and rivets are stainless steel. n = NEMA 3R rated n = NEMA 1R rated n G90 galvanized Steel n ANSI 61 Paint n EUSERC drawing #'s 31 and 353 n Custom options available! Details on page Siemens Industry, Inc. SPEEDFAX 011 Product Catalog

14 Type WMT Test Block Bypass Meter Stacks 06/01/13 n 5A 1-3 positions n 100A thru-bus rating n AIC Rating (100k) Commercial ring type meter stacks: Test Block Bypass c Catalog Catalog Meter positions Dimensions (inches) a provisions Maximum AIC Height Width Depth 1-phase, 3-wire SN, incoming and outgoing, test block bypass, 4-jaw sockets b Max. tenant breaker (Amps): 5 WMT115 MT TB-1 WMT15 MT15 QS, QSH, QSHH, HQS, HQSH, QP, QPH, HQP, 100k TB- MP-T, MP-HT, MP-MT WMT315 MT TB-3 3-phase, 4-wire SN, incoming and 1-phase, 3-wire SN outgoing, test block bypass, 5-jaw sockets b e Max. tenant breaker (Amps): 5 Phase Knockout diagram WMT15J MT15J AB TB-1 WMTAB5J MTAB5J BC, 1-CA WMTBC5J MTBC5J QS, QSH, QSHH, HQS, HQSH, QP, QPH, HQP, MP-T, MP-HT, MP-MT 100k AB, 1-CA WMTCA5J MTCA5J AB, 1-BC WMT35J MT35J phase, 4-wire SN, incoming and outgoing, test block bypass, 7-jaw sockets d Max. tenant breaker (Amps): 5 1-AB, 1-BC, 1-CA TB- TB-3 Metering WMT WMT135J MT135J TB-4 WMT35J MT35J QJ, QJH, QJH, MQ, MQH, MQL 100k TB-5 WMT335J MT335J TB-6 a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions. b Not for use on 3-phase,4-wire delta systems. c Max AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. d Rated for use with 40/10V Delta systems. Commercial Stacks are not field phaseable. Siemens Industry, Inc. SPEEDFAX 011 Product Catalog -111

15 0/18/14 Power Mod Type WMT Test Block Bypass Meter Stacks: Knockout Diagrams Typical top view for NEMA 1 Metering WMT Metering TB-1 WMT15J MT15J WMT115 MT115 TB- WMTAB5J MTAB5J WMTBC5J MTBC5J WMTCA5J MTCA5J WMT115 MT115 TB-4 TB-3 WMT315 MT315 WMT35J MT35J WMT135J TB-5 WMT35J -11 MT35J Siemens Industry, Inc. SPEEDFAX 011 Product Catalog WMT135J TB-6 WMT335J MT335J

16 Type WMK K-Base Meter Stacks 06/01/13 K-Base Meter Stacks Commercial K-Base Meter Stacks (type WMK) are designed to meet the requirements of those utilities specifying bolt-in meter sockets for 400 and 600 Amp residential and commercial applications. Features include: n QuickSystem features n Exclusive Landis & Gyr K4, K5, & K7 meter sockets n 1 position K4, K5, K7 modules with 400 & 600 Amp tenant mains n position K7 module with 400 Amp tenant main n Space saving design K-Base quick reference n 400A & 600A 1- positions n 100A Thru bus-rating n UL Standard # UL67 n UL file # E7100 n AIC Rating (5k) n Voltage Single Phase 10/40V AC Max Three In Single Phase Out 08Y/10V AC Three Phase 40V AC Max n All swing latches and rivets are stainless steel n NEMA 3R rated n G90 Galvanized Steel n ANSI 61 Paint n Custom options available! Details on page Metering WMK Siemens Industry, Inc. SPEEDFAX 011 Product Catalog -113

17 Type WMK K-Base Meter Stacks 06/01/13 n 400A & 600A 1- positions n 100A Thru busrating n AIC Rating (5k) Commercial ringless type meter stacks: K-Base bolt-in, 5k AIC c f Metering WMK Catalog Meter positions Max. tenant breaker (Amps) provision d Maximum AIC Rating 1-phase, 3-wire SN, incoming and outgoing, K4 K-Base bolt-in WMK11400R d JXD6B400 Factory Inst. Dimensions (inches) a Height Width Depth 5k WMK11600R g LXD6B k Factory Inst. 3-phase, 4-wire SN, incoming and 1-phase, 3-wire SN outgoing, K5 K-Base bolt-in b f WMK1400RJ d JXD6B400 Factory Inst. Phase Knockout Diagram KB-1 5k AB KB- JXD6B400 WMK400RJ 400 5k AC KB-3 Factory Inst. 3-phase, 4-wire SN, incoming and outgoing, K7 K-Base bolt-in e WMK13400RJ d 1 JXD63B KB k WMK3400RJ d Factory Inst KB-3 WMK13600RJ g LXD63B600 Factory Inst. 5k KB- 1 Meter Position Per Stack Amperage Alternate amperage breakers Ad Suffix 1 Meter Position Per Stack T1 T T3 T4 T19 T0 Amperage 00A 50A 300A 350A 450A 500A Ad Suffix T5 T6 T7 T8 T9 T10 T11 T1 T13 T14 T15 T16 T17 00A/00A 00A/50A 00A/300A 00A/350A 00A/400A 50A/300A 50A/350A 50A/400A 300A/300A 300A/350A 300A/400A 350A/350A 350A/400A a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions. b Not for use on 3-Phase 4-wire delta systems. c Max AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. Higher overall ratings may be achieved through approved series rating combinations. d Alternate amperage breakers are available. Please see table below for suffix that needs to be added for ordering. Extended leadtime may apply. Contact sales office for more details. e Rated for use with 40/10V Delta systems f Commerical Stacks are not field phaseable g Alternate amperage breakers are available (T19 and T0). Please see table below for suffix that needs to be added for ordering. Extended leadtime may apply. Contact sales office for more details. T18 50A/50A -114 Siemens Industry, Inc. SPEEDFAX 011 Product Catalog

18 0/18/14 Power Mod Type WMK K-Base Meter Stacks: Knockout Diagrams KB- KB-1 WMK11400R WMK11600R WMK1400RJ WMK13400RJ WMK13600RJ Metering WMK Metering KB-3 WMK400RJ WMK3400RJ Siemens Industry, Inc. SPEEDFAX 011 Product Catalog -115

Power Mod. Meter Stacks: WMM Residential Stacks. Residential Meter Stacks

Power Mod. Meter Stacks: WMM Residential Stacks. Residential Meter Stacks Meter Stacks: WMM Residential Stacks Residential Meter Stacks Power Mod s core offering of Residential Meter Stacks, type WMM, offers the widest product offering and flexibility in the industry. Each meter

More information

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module

More information

Power Mod. Introduction.

Power Mod. Introduction. Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

Power Mod. Standard Tapboxes.

Power Mod. Standard Tapboxes. Power Mod Standard tapbox modules (type WTB) are designed for versatility, space savings, and flexibility. Features include: J QuickSystem features J Standard compression lug capability J Invertibility:

More information

SIEMENS RESIDENTIAL SERVICES. 120/240V 1 PH 3W 4 Terminal 100 Amp Socket Only, Overhead Surface Use 200 Amp socket (SUAT327-OGWR)

SIEMENS RESIDENTIAL SERVICES. 120/240V 1 PH 3W 4 Terminal 100 Amp Socket Only, Overhead Surface Use 200 Amp socket (SUAT327-OGWR) RESIDENTIAL SERVICES 100 Amp Socket Only, Overhead Use 200 Amp socket (SUAT327-OGWR) 100 Amp Meter Socket & Circuit Breaker Combination, Overhead SUAT327-OGWR + EC659-0121 MM0406L1125SEC*, MC1224B1100SEC,

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

500 Ocean Breaker Electrical Submittals

500 Ocean Breaker Electrical Submittals X 02/5/6 JDF Submittal #093 DIV 6 IMC RESUBMITTAL #2 Electrical Gear #640, #6442 500 Ocean Breaker Electrical Submittals Interrupting Capacity Ratings Of Disconnect Devices Molded Case Circuit Breakers

More information

Meter Centers Meter Mounting Devices

Meter Centers Meter Mounting Devices Meter Mounting Devices General General Information Materials: 16 gauge, galvanized steel, G-90 Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

Meter Mains - Without Bypass

Meter Mains - Without Bypass - 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION

More information

Selection & Application Guide. BFT Main Feed Thru Modules. Power Mod. usa.siemens.com/powermod

Selection & Application Guide. BFT Main Feed Thru Modules. Power Mod. usa.siemens.com/powermod Selection & Application Guide BFT Main Feed Thru Modules Power Mod usa.siemens.com/powermod Power Mod BFT - Main Feed Thru Modules Selection and Application Guide Power Mod BFT - Main Feed Thru Modules

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

Meter Centers & Loadcenters Group Metering

Meter Centers & Loadcenters Group Metering June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

22,000 A IR Catalog Number QA115AFCH QA120AFCH Q215AFCH Q220AFCH. 65,000 A IR Catalog Number QA115AFCHH QA120AFCHH QA115AFH QA120AFH

22,000 A IR Catalog Number QA115AFCH QA120AFCH Q215AFCH Q220AFCH. 65,000 A IR Catalog Number QA115AFCHH QA120AFCHH QA115AFH QA120AFH 06/3/4 Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to

More information

POWER PRODUCT Meter Centres Contents

POWER PRODUCT Meter Centres Contents POWER PRODUCT Meter Centres Contents General Specifications - Catalogue Numbering System - 40V Meter Centre Overview - Features & Benefits -3 Procedure -5 Switches and Tap Boxes -6 Meter Stacks -7 Socket

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

Q115AFHn a Q120AFHn a. Q215AFCHn a Q220AFCHn a. QF115H a QF120Hn a QF130H QF215H QF220H QF230H QF240H QF250H QF260H

Q115AFHn a Q120AFHn a. Q215AFCHn a Q220AFCHn a. QF115H a QF120Hn a QF130H QF215H QF220H QF230H QF240H QF250H QF260H Arc-Fault and Ground-Fault s Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The

More information

Multiple Metering, Vertical Gang

Multiple Metering, Vertical Gang Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or

More information

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .11 Metering Products Systems for Residential and Commercial Application Systems for Residential and Commercial Applications Product Description Group metering is a service entrance product line that consists

More information

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential

More information

SPEEDFAX TM 2011 Meter Centers Contents

SPEEDFAX TM 2011 Meter Centers Contents SPEEDFAX TM 011 Meter Centers Contents Single and Multiple s - -19 General Information - -3 Single Position s - Residential Types -4-5 Multiple Position s Residential Types -6-7 Single Position s Commercial

More information

Selection and Application Guide For use in New England EQUIPMENT

Selection and Application Guide For use in New England EQUIPMENT Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Multiple Metering, Horizontal Gang - Non Lever Bypass

Multiple Metering, Horizontal Gang - Non Lever Bypass Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground

More information

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment Single Meter Sockets, Without ypass -............................ 57-58 Meter Mains, With Optional MCC ypass -......................... 59-60 Meter Main Load Centers, With Optional MCC ypass -..........

More information

EZ Meter-Pak Meter Centers

EZ Meter-Pak Meter Centers NEMA 3 onstruction Vac Maximum, for use on A systems, suitable for use as ervice Equipment. tility ompany equirements: eview local utility requirements to ensure that metering equipment meets their standards.

More information

Modular Metering Construction Details

Modular Metering Construction Details GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Selection and application guide. For use in Ohio. Meter Mounting Equipment.

Selection and application guide. For use in Ohio. Meter Mounting Equipment. Selection and application guide For use in Ohio Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and general

More information

Modular Metering Application Guide

Modular Metering Application Guide GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III

More information

Selection and application guide

Selection and application guide Selection and application guide For use in Colorado and Wyoming Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction

More information

Selection and Application Guide For use in New Jersey and New York EQUIPMENT

Selection and Application Guide For use in New Jersey and New York EQUIPMENT Selection and Application Guide For use in New Jersey and New York EQUIPMENT Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase, 3 Wire

More information

Modular Metering Application Guide. Meter Mod * III Product Family

Modular Metering Application Guide. Meter Mod * III Product Family Modular Metering Application Guide Meter Mod * III Product Family Table of Contents Page No. Selection Guidelines and Nomenclature 3 UL Standard Listing and File Numbers for Meter Mod III Product Family

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Selection and application guide. For use in Kansas, Iowa, Missouri and Illinois. Meter mounting equipment.

Selection and application guide. For use in Kansas, Iowa, Missouri and Illinois. Meter mounting equipment. Selection and application guide For use in Kansas, Iowa, Missouri and Illinois Meter mounting equipment www.landisandgyr.com Contents Service Rating Positions Terminals Page Introduction and General Information

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

Selection and application guide. For use in Texas. Meter Mounting Equipment.

Selection and application guide. For use in Texas. Meter Mounting Equipment. Selection and application guide For use in Texas Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and General

More information

Selection and application guide

Selection and application guide Selection and application guide For use in Louisiana and Mississippi Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction

More information

Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families

Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families Modular Metering Stock Selection Guide Meter Mod * III and Mini Mod * III Product Families Table of Contents Page No. Nomenclature 3 Main Breaker Module, Single-Phase, 3 Wire, 0/40 Vac 4 Main Breaker Module,

More information

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant

More information

REC Municipal Meter Mounting Equipment

REC Municipal Meter Mounting Equipment REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

Selection and application guide

Selection and application guide Selection and application guide For use in Pennsylvania and West Virginia Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page

More information

Metering NEED. Meter Sockets. Product Description

Metering NEED. Meter Sockets. Product Description Meter Sockets Meter Sockets Single Position (Ring, Ringless and Bypass)........ - Multiple Position Without Tenant Main Breakers.......... - Accessories.......................... -7 Meter Packs (All-in-Ones)

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

For vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed

For vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed Multiple Vertical APPLICATION For vertical multi-meter installations 1-6 meter positions esigned to receive watthour meters that meet ANSI C12.10 Overhead or underground feed CONSTRUCTION Type 3R construction

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue

More information

Type MP-T Type MP-HT Type MP-MT

Type MP-T Type MP-HT Type MP-MT CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List

More information

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection .11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box

More information

Selection and application guide

Selection and application guide Selection and application guide For use in Tennessee Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

Enclosed Circuit Breakers Enclosures Type 1

Enclosed Circuit Breakers Enclosures Type 1 s Type Selection Figure Figure Figure Type K.O. Number Maximum Weight Fig. Breaker of Current Catalog List Lb./Ship. (inches) 6 Plcs. Plcs. No. Frame Poles Rating Number Price $ Package A B C D E F G H

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Approved Meter Sockets for Use in. New Jersey, Delaware, Maryland. Issued 7/07/07 Revised 1/19/2018 Page 1 of 9 Atlantic City Electric/Delmarva Power

Approved Meter Sockets for Use in. New Jersey, Delaware, Maryland. Issued 7/07/07 Revised 1/19/2018 Page 1 of 9 Atlantic City Electric/Delmarva Power Approved Meter Sockets for Use in New Jersey, Delaware, Maryland Page 1 of 9 1. INDEX. 2 2. INTRODUCTION.. 3 2. RESIDENTIAL & COMMERCIAL METER SOCKETS.. 3-4-5 2. SINGLE PHASE GANG SOCKETS 6 3. THREE PHASE

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are

More information

Duke Energy (and its legacy Progress Energy subsidiary) will be requiring metering equipment that meets the Meter Equipment Group (MEG) specifications beginning January 1, 2016. Included in this document

More information

CON EDISON EQUIPMENT

CON EDISON EQUIPMENT CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... - - - ASCO is there for you even when you re not - SERIES - SERIES SERIES -

More information

SP 30A 120/240V CB. Features. Dimensions and Weight Height 3 Length Width 1. Long Description. Manufacturer Information

SP 30A 120/240V CB. Features. Dimensions and Weight Height 3 Length Width 1. Long Description. Manufacturer Information 3804 South Street 5964-263, TX Nacogdoches Phone: 936-569-94 Fax: 936-560-4685 AllenWatson@elliottelectric.com Q SP A /240V CB Siemens Energy Inc Manufacturer Description Weight per unit Product Category

More information

Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT

Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT 2011 81 APPENDIX A: APPROVED METERING EQUIPMENT TABLE OF CONTENTS Approved Metering Equipment... A-1

More information

Selection and application guide

Selection and application guide Selection and application guide For use in New York State Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction

More information

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design Selection and Application Guide busway system XJ-L Cost-effective Power Distribution Compact Design Specifications New for 2007..400A XJ-L Busway XJ-L Busway is available up to 400A. First introduced in

More information

Meter Mains - With Optional MCC Bypass

Meter Mains - With Optional MCC Bypass Meter Mains - With Optional MCC ypass pplication Combination meter/main with optional manual circuit closing (link type) bypass Factory installed breaker Receive SI C12.10 watthour meters Surface mount

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Louisiana & Mississippi Area Catalog

Louisiana & Mississippi Area Catalog Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

5.11. Metering Products. Contents Description Systems for Residential and Commercial

5.11. Metering Products. Contents Description Systems for Residential and Commercial 3MM, 37MM, 3SS and 37SS Main Tenant ircuit reakers V2/EHD2100 ontents Description Systems for Residential and ommercial pplications............................ Meter Packs.............................

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

WPS SERVICE MANUAL. Section Amp and Smaller - Common

WPS SERVICE MANUAL. Section Amp and Smaller - Common Revised 01/2017 Section 2 200 AMP AND SMALLER - COMMON Page 1 of 17 Section 2 200 Amp and Smaller - Common 2-0 General Metering Requirements... 2 2-1 Basic Calculations... 4 2-2 100-200 Amp Single-Phase

More information

Louisiana/Mississippi. Area Catalog

Louisiana/Mississippi. Area Catalog Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

22.000A IR. Catalog Number. Price $

22.000A IR. Catalog Number. Price $ Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List

More information

Load Centers

Load Centers Siemens would like to welcome the urray Electrical Products into the Speedfax. The urray Electrical Products catalog and Siemens Speedfax has been combined for our customer s convienience. ll of the urray-branded

More information

Customer Requirements Meter Socket Configurations

Customer Requirements Meter Socket Configurations Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements

More information

Meter Mounting Equipment Colorado Area

Meter Mounting Equipment Colorado Area Meter Mounting Equipment Colorado Area milbank overview milbank overview Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. aldrop, 9-00 Robert F. aldrop, II Chairman Katrina aldrop Henke Vice Chairman

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

METERING REQUIREMENTS

METERING REQUIREMENTS METERING REQUIREMENTS KUA will not accept a non-securable service trough entrance. That is, all enclosed conductors prior to the meter (line side) will be securable by and accessible to KUA personnel only.

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

(CT, NH, ME, RI, VT, MA)

(CT, NH, ME, RI, VT, MA) Selection and application guide For use in New England States (CT, NH, ME, RI, VT, MA) Meter Mounting Equipment www.talonmetering.com 1 Meter Mounting Equipment Table of Contents Service Rating Positions

More information