www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Size: px
Start display at page:

Download "www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003"

Transcription

1 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under WARRANTY QUALIFICATIONS on page 2. SPECIAL TO THIS PRODUCT: INCLUSIONS: SMD-20 and SMD-40 Mountings Complete mountings include fuse-unit end fittings. Fuseunit end fittings for SMD-40 Power Fuses include Silencer. A choice of connector arrangements is available with complete mountings as listed in the table on page 12. Specify the connector arrangement desired by adding the appropriate suffix letter to the catalog number of the selected mounting. Each overhead pole-top style SMD-20 Mounting includes mounting bracket and hardware. EXCLUSIONS: SMD-20 and SMD-40 Mountings Mountings do not include fuse units. SM-4 and SM-5 Mountings Complete mountings and live parts do not include holders or refill units. Complete mountings and live parts do not include connectors. Various connectors are available as listed in the table on page 13. Specify quantity and catalog number of connectors desired. SPECIFICATION DEVIATIONS: SMD-20 and SMD-40 Mountings Live parts are not available separately for SMD-20 and SMD-40 Power Fuses. Station style SMD-20 and SMD-40 Mountings are offered with a choice of Cypoxy a or porcelain station post insulators. The standard insulator color is gray. When mountings are to be provided with special insulators, consult your nearest S&C Sales Office for availability. Station style mountings (except station right-angle style) can be supplied less insulators; add suffix -Z1 to the catalog number. Supersedes Specification Bulletin dated SPECIFICATIONS ç3 Station style mountings (except station right-angle style) of a given voltage rating can be provided with insulators of the next lower voltage rating add suffix -Z2 to the catalog number, or the next higher voltage rating add suffix -Z3 to the catalog number.f Station style mountings cannot be supplied less bases. Station style mountings (except station right-angle style) can be supplied with tin-plated terminal pads. To specify, add suffix -Z5 to the catalog number. Overhead pole-top style SMD-20 Mountings cannot be supplied less insulators. SM-4 and SM-5 Mountings SM-4 and SM-5 Mountings are offered with a choice of Cypoxy or porcelain station post insulators. The standard insulator color is gray. When mountings are to be provided with special insulators, consult your nearest S&C Sales Office for availability. Mountings can be supplied less insulators; add suffix -Z1 to the catalog number. Mountings of a given voltage rating can be provided with insulators of the next lower voltage rating add suffix -Z2 to the catalog number, or the next higher voltage rating add suffix -Z3 to the catalog number.f Mountings can be supplied less bases but including insulators, add suffix -Z4 to the catalog number. Mountings can be supplied with tin-plated terminal pads. To specify, add suffix -Z5 to the catalog number. Disconnect style parallel SM-5 Power Fuses are furnished with aluminum terminal pads as a standard feature. a Cypoxy is the S&C trademark for S&C s cycloaliphatic epoxy resin system. Cypoxy is nontracking, self-scouring, nonweathering... there s never a compromise of insulation integrity. S&C Cypoxy station post insulators meet or exceed the electrical and mechanical-strength requirements established in ANSI Standard C29.9 (1983) for porcelain standardstrength station post insulators. f Mountings rated 4.8 kv or 7.2 kv cannot be provided with lower rated insulators. Fuse mountings rated kv provided with insulators of the next lower voltage rating will be furnished with porcelain station post insulators rated 7.2 kv, T.R. No Fuse mountings rated kv provided with insulators of the next higher voltage rating will be furnished with porcelain station post insulators rated 46 kv, T.R. No S&C Power Fuses Types SM and SMD are manufactured in accordance with a quality system certified to ISO 9001:0, and they are Rural Utilities Service (RUS) approved. Page 1 of

2 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale Continued WARRANTY QUALIFICATIONS: SMD-20 and SMD-40 Mountings The standard warranty contained in seller s standard conditions of sale (as set forth in Price Sheet ) does not apply to S&C SMD-20 or SMD-40 Mountings when installed in conjunction with fuse units or end fittings of other than S&C manufacture, nor does it apply to S&C fuse units or end fittings installed in mountings of other than S&C manufacture. Page 2 of SM-4 and SM-5 Mountings For the standard warranty contained in seller s standard conditions of sale (as set forth in Price Sheet ) to apply to live parts when ordered separately, the live parts must be assembled on mountings in accordance with S&C Instruction Sheet The standard warranty contained in seller s standard conditions of sale (as set forth in Price Sheet ) does not apply to S&C SM Mountings when installed in conjunction with fuses of other than S&C manufacture.

3 How to Order a Complete Power Fuse Types SMD-20 and SMD Obtain the catalog number of the desired mounting from the column entitled, Mounting on page 4. Note: Live parts for SMD-20 or SMD-40 Power Fuses cannot be ordered separately. 2. Obtain the catalog number of the applicable SMU-20 or SMU-40 fuse unit from the tables on pages 6 through 8, taking care to match the voltage rating of the fuse unit to that of the mounting. 3. Select the desired connector arrangement from the table on page 12. Add the indicated suffix letter to the catalog number of the mounting selected in Step 1, above. 4. Obtain the catalog number of desired conversion kits, parts, and maintenance supplies from the tables listed on page 14. How to Order Handling Tools Obtain the catalog number(s) of recommended handling tool(s) from the table on page 14. Refer to Specification Bulletin Types SM-4 and SM-5 1. Obtain the catalog number of the desired mounting from the column entitled, Mounting on page 5. If only live parts are desired, refer to the LIVE PARTS table on page Obtain the catalog number of the applicable holder from the Holder column on page 5, reading from the same line in which the selected mounting is listed. 3. Obtain the catalog number of the applicable refill unit from the tables on pages 9 through 11, taking care to match the voltage rating of the refill unit to that of the mounting. Note: For each mounting rated 720E amperes, order two holders and two refill units. 4. Obtain the catalog number of the desired connector from the table on page 13. Order two connectors for each mounting or set of live parts. 5. Obtain the catalog number of desired parts from the table listed on page 15. How to Order Handling Tools Obtain the catalog number(s) of recommended handling tools(s) from the table on page 15. Refer to Specification Bulletin Page 3 of

4 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) SMD-20 AND SMD-40 MOUNTINGS Less Connectors12 Style Overhead Pole-Top67 Overhead Pole-Top67 Station Vertical-Offset6 Station Inverted6 Station Right-Angle67 Station Vertical8 Page 4 of Type SMD-20 kv Rating Nom. Max BIL Max4 d 1 Amperes, RMS, Sym.3 Interrupting Leakage Distance to Ground, Minimum, Inches of Mounting (Including Live Parts and End Fittings, less Connectors5) Cypoxy Station Post Porcelain Station Post 92122R3a 92142R3a 92123R3a Page Reference for Dimensional Information SMD ¹ ₂ 944R3a 17 SMD-20 SMD-20 SMD-20 SMD For available connector arrangements, refer to page SMD-20 and SMD-40 Live Parts are not available separately. 3 Symmetrical ratings assigned are based on available short-circuit current at locations where the X/R ratio is l5. The interrupting ratings expressed in amperes RMS asymmetrical are 1.6 times the symmetrical ratings listed. Higher symmetrical ratings have been determined for SMD-20 Power Fuses where X/R = 10 and X/R = 5. These higher ratings as well as asymmetrical ratings are given in S&C Descriptive Bulletin SMU-20 Fuse Units for use in SMD-20 Mountings are available in ratings through K amperes as well as amperes. 5 Specify connectors, if desired, by adding the appropriate suffix letter to catalog number. For example, SMD-20 Outdoor Distribution Power Fuse Mounting, Station Vertical-Offset Style, R2-L. (See table, page 12.) 6 All SMD-20 Mountings are equipped with attachment hook to accommodate Loadbuster ¹ ₂ 37 15¹ ₂ 37 15¹ ₂ 37 15¹ ₂f 15¹ ₂ R2-E R2-E 1904-E E E E R3-Ea R3-Ea R3-Ea R R R3a R3a R3a SP SP SP Connectors must be specified for Overhead Pole-Top Style and Right-Angle Style SMD-20 Mountings, refer to page SMD-40 Mountings can be equipped with an optional attachment hook to accommodate Loadbuster. Specify by adding suffix -LB to the catalog number of the SMD-40 Mounting. d Also suitable for protection of single-phase-to-neutral circuits (lines or transformers) on 20/ GrY-kV systems. a For provisions only for NEMA pad-terminal connectors or two-hole compression connectors, add suffix -G to catalog number. f Mounting includes -kv -kv BIL Cypoxy station post insulators. Leakage distance to ground is 10¹ ₂ inches (267 mm) for mountings with 95-kV BIL porcelain station post insulators; i.e., SP.

5 SM MOUNTINGS AND HOLDERS Less Refill Units Style Disconnect 180 Opening Vertical5 Disconnect 90 Opening Inverted Non-Disconnect Vertical Non-Disconnect Upright Type SM-4 SM-5 SM-5 SM-4 SM-5 SM-4 SM-5 kv Rating Nom. Max BIL Max Amperes, RMS, Sym.1 720E 720E 1 Symmetrical ratings assigned are based on available short-circuit current at locations where the X/R ratio is l5. The interrupting ratings expressed in amperes RMS asymmetrical are 1.6 times the symmetrical ratings listed. Higher symmetrical ratings have been determined for these fuses applied at lower system voltages and in locations where X/R = 10 and X/R = 5. These higher ratings as well as asymmetrical ratings are given in S&C Descriptive Bulletin For live parts furnished separately, refer to the table on page For available connectors, refer to the table on page Holder does not carry Snuffler or Silencer. Interrupting d 000k d d d Mounting2 (Including Live Parts, less Connectors3 less Holder) Cypoxy Station Post R1-Ef R1-E R1-E R1-E R2-Ef R3-Ef R2-E R3-E R2-E R2-E R2-Ef R2-E R2-E R2-E R1-Ef R1-E R1-E R1-E R2-Ef R2-E R2-E R2-E R1-Ef R1-E R1-E R1-E R2-Ef R2-E R2-E R2-E Porcelain Station Post R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R2 Holder R R2l 86152R R2l 86153R R R R R R R R R R R R R R2 862R2 863R2 864R2 864R2 Page Reference for Dimensional Information All SM-4 Mountings in the Disconnect 180 Opening Vertical Style can be equipped with attachment hook to accommodate Loadbuster. Specify by adding suffix -LB to catalog number of the mounting. d 60-hertz rating. For systems rated above 15.5 kv through kv, interrupting rating is,000 amperes RMS symmetrical, 50/60 hertz. k 60-hertz rating. f Mounting includes -kv -kv BIL Cypoxy station post insulators. Product discontinued. l Two holders required with each mounting. Page 5 of

6 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) SMU-20 FUSE UNITS (For use in SMD-20 Mountings) Rating, Amperes 3K 6K 8K 10K 12K 15K 20K K 30K 40K 50K 65K 80K 100K 140K K Page 6 of K Ratings S&C K TCC Rating, Amperes kv Nominal, kv Max 5E 7E 10E 13E 15E 20E E 30E 40E 50E 65E 80E 100E 1E E 175E TCC E 701 TCC E Ratings S&C Slow TCC S&C Very Slow TCC

7 SMU-20 FUSE UNITS (For use in SMD-20 Mountings) Continued Rating, Amperes Rating, Amperes 3K 6K 8K 10K 12K 15K 20K K 30K 40K 50K 65K 80K 100K 140K K 3K 6K 8K 10K 12K 15K 20K K 30K 40K 50K 65K 80K 100K 140K K K Ratings K Ratings S&C K TCC S&C K TCC Rating, Amperes Rating, Amperes kv Nominal, kv Max1 TCC E TCC E E E E E E E E E E E E E E 6131 E E kv Nominal, kv Max TCC E E 7E 10E 13E 15E 20E E 30E 40E 50E 65E 80E 100E 1E E 175E 1 Also suitable for protection of single-phase-to-neutral circuits (lines or transformers) on 20/ GrY-kV systems. TCC E Ratings E Ratings S&C Slow TCC S&C Slow TCC S&C Very Slow TCC S&C Very Slow TCC Page 7 of

8 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Page 8 of SMU-40 FUSE UNITS (For use in SMD-40 Mountings) Rating, 4.8 kv Nominal, 5.5 kv Max kv Nominal, kv Max kv Nominal, 29 kv Max Amperes TCC TCC TCC S&C Slow S&C Slow S&C Slow TCC TCC TCC TCC TCC TCC E 5E 7E 10E 13E 15E 20E E 30E 40E 50E 65E 80E 100E 1E E 175E 0E

9 SM-4 REFILL UNITS (For use in SM-4 Holders) Rating, Amperes Rating, Amperes 1 2 3E 5E 7E 10E 13E 15E 20E E 30E 40E 50E 65E 80E 100E 1E E 175E E 5E 7E 10E 13E 15E 20E E 30E 40E 50E 65E 80E 100E 1E E 175E 7.2 kv Nominal, 8.3 kv Max1 kv Nominal, kv Max TCC R R4 TCC R R R R R4 1210R R R R R R4 120R4 1211R4 121R4 121R4 1210R4 1215R R4 S&C Slow TCC R4 1030R4 1040R4 1050R4 1060R4 1075R4 0R4 11R4 1R4 1R4 10R4 15R4 1300R4 TCC R4 122R4 TCC R4 127R R R R4 1220R R R R R R R4 1221R4 122R4 122R4 1220R4 12R R4 S&C Slow TCC R4 2030R4 2040R4 2050R4 2060R4 2075R4 2100R4 21R4 2R4 2R4 20R4 R4 2300R4 kv Nominal, kv Max kv Nominal, kv Max TCC R R4 TCC R R R R R4 1230R R R R R R R4 1231R4 123R4 123R4 1230R4 1235R R4 S&C Slow TCC R4 3030R4 3040R4 3050R4 3060R4 3075R4 3100R4 31R4 3R4 3R4 30R4 35R4 3300R4 1 Rated 7.2 kv nominal for use in SM-4 Holders rated 7.2 kv. f This S&C Coordinating refill unit should be applied where the maximum continuous load current does not exceed amperes and TCC R4 1002R4 TCC R4 1007R4 1010R4 1015R4 1020R4 10R4 1030R4 1040R4 1050R4 1060R4 1075R4 1100R4 11R4 1R4 1R4 10R4 15R4 1300R4 S&C Slow TCC R4 4030R4 4040R4 4050R4 4060R4 4075R4 4100R4 41R4 4R4 4R4 40R4 45R4 4300R4 S&C Coord. TCC R4f where all fault currents below 1000 amperes will be cleared by another fuse. Page 9 of

10 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) SM-5 REFILL UNITS (For use in SM-5 Holders) Rating, Amperes 1 2 3E 5E 7E 10E 13E 15E 20E E 30E 40E 50E 65E 80E 100E 1E E 175E 0E Rating, Amperes Page 10 of 4.16 kv Nominal, 4.76 kv Max1 7.2 kv Nominal, 8.3 kv Max2 TCC TCC R R R R4 S&C Slow S&C Coord. S&C Slow S&C Coord. TCC TCC TCC TCC TCC TCC R R R R R R R R R R4 1300R4 2600R4 1310R R R R R R R R R R R R R R R R R R4 130R4 1301R4 2601R4 1311R4 130R4 260R4 131R4 130R4 260R4 131R4 1300R4 2600R4 1310R4 1305R4 2605R4 1315R R R R R R R R R R4 130R4 260R R R R R4 1410R4df 1410R4f 1420R4df 1420R4f kv Nominal, kv Max kv Nominal, kv Max TCC TCC R4 132R R R4 S&C Slow S&C Coord. S&C Slow TCC TCC TCC TCC TCC E 5E 7E 10E 13E 15E 20E E 30E 40E 50E 65E 80E 100E 1E E 175E 0E 135R4 137R R R R4 1320R R R R R R R4 1321R4 132R4 132R4 1320R4 13R R4 1300R4 1300R R4 2620R R R R R R R4 2621R4 262R4 262R4 2620R4 26R R4 2600R4 2600R R R R R R R4 1330R R R R R R R4 1331R4 133R4 133R4 1330R4 1335R R R R4 2630R R R R R R R4 2631R4 263R4 263R4 2630R4 2635R R R R R4f 20R4f 1 Rated 4.16 kv nominal, for use in SM-5 Holders rated 7.2 kv when applied in listed mountings rated 7.2 kv for system voltages through Interrupting ratings are those listed in S&C Descriptive Bulletin 2-30 for 7.2-kV SM-5 Power Fuses applied to systems rated 2.4/4.16 Y kv kv. f These S&C Coordinating refill units should be applied where 2 Rated 7.2 kv nominal, for use in SM-5 Holders rated 7.2 kv when applied in listed mountings rated 7.2 kv for system voltages through 4.8 kv through 7.2 kv. the maximum continuous load current does not exceed 400 amperes and where all fault currents below 3000 amperes for s 1410R4 and 10R4 and 4000 amperes for s d Catalog numbers are in italics because these are 7.2-kV refill units. 1420R4 and 20R4 will be cleared by another fuse.

11 SM-5 REFILL UNITS (For use in SM-5 Holders) Rating, kv Nominal, kv Max Amperes 1 2 3E 5E 7E 10E 13E 15E 20E E 30E 40E 50E 65E 80E 100E 1E E 175E 0E TCC R R4 TCC R R R R R4 1340R R R R R R R4 1341R4 134R4 134R4 1340R4 1345R R R R4 S&C Slow TCC R R R R R R R4 2641R4 264R4 264R4 2640R4 2645R R R R4 Page 11 of

12 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Page 12 of CONNECTORS Two Provided per Mounting For use with SMD-20 and SMD-40 Mountings Illustration Description Parallel-Groove Connectors Bronze Body, Tin Plated, Single ¹ ₂ 13 2¹ ₂ Galvanized Steel Bolt Aluminum-Alloy Body, Tin Plated, Two ¹ ₂ 13 2¹ ₂ Galvanized Steel Bolts Provision only for NEMA pad-terminal connectors or two-hole compression connectors. Includes tin plated terminal adapters but does not include hardware Eye-Bolt Connectors To Specify Connector Arrangement d Applies only to station right-angle and overhead pole-top style SMD-20 Mountings. Accommodating Conductors Size and Material Two No. 6 solid (13.3 mm 2 ) through No. 2 stranded (44.4 mm 2 ) copper or aluminum in one groove, No. 2 solid (33.6 mm 2 ) through 0 kc mil (168 mm 2 ) stranded copper or aluminum, or 4/0 ACSR (161 mm 2 ) in the other groove No. 2 solid (33.6 mm 2 ) through 500 kc mil (335 mm 2 ) stranded copper or aluminum, or kc mil ACSR (329 mm 2 ) No. 2 solid (33.6 mm 2 ) through 500 kc mil (335 mm 2 ) stranded copper or aluminum, or kc mil ACSR (329 mm 2 ) No. 8 solid (8.4 mm 2 ) through 0 kc mil (168 mm 2 ) stranded copper or aluminum, or 4/0 ACSR (161 mm 2 ) Add Catalog Number Suffix -Dd -K -L -Gd -Md

13 CONNECTORS For use with SM-4 and SM-5 Mountings Illustration and Description Aluminum Alloy Body, Tin Plated, Two ¹ ₂ 13 2³ ₄ Galvanized Steel Bolts Aluminum Alloy Body, Tin Plated, Two ¹ ₂ 13 2¹ ₄ Galvanized Steel Bolts Standard Bronze-Pad Terminal, Tin Plated, Four-Bolt. Includes ¹ ₂-inch galvanized steel hardware for attachment to terminal pads of fuses Accommodating Conductor No. 2 solid (33.6 mm 2 ) through 500 kc mil (335 mm 2 ) stranded copper or aluminum No. 2 solid (33.6 mm 2 ) through 500 kc mil (335 mm 2 ) stranded copper or aluminum No. 6 solid (13.3 mm 2 ) through 0 kc mil (168 mm 2 ) copper or aluminum 1/0 solid (53.5 mm 2 ) through 500 kc mil (335 mm 2 ) copper or aluminum 2/0 stranded (89 mm 2 ) through 800 kc mil (539 mm 2 ) copper or aluminum Upper Terminal Pad Lower Terminal Pad 4741R R1-A 4564R1-B 4565R1-A 4565R1-B 4567R1-A 4567R1-B Page 13 of

14 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) CONVERSION KITS For use with SMD-20 Power Fuses MAINTENANCE SUPPLIES For use with SMD-20 and SMD-40 Power Fuses Page 14 of Item For Fuse Unit Fuse-Unit Recoating Kit one-half pint Light Gray Epoxy Polyester Gloss Enamel 13-E-1 and one-half pint Catalyst 13-C-0 (two coats for ten fuse units).1 Requires thinner listed below Item Conversion Kit, adapts superseded -kv station vertical-offset style mountings1 to accept shorter, 28¹ ₂-inch (7 mm) -kv SMU-20 Fuse Units listed on page 7 [superseded length was 34¹ ₄ inches (870 mm)] 1 Identified by the following catalog numbers: 922R2 1922R2 1922R2-HF 922R1 1922R1 1922R1-HF HF PARTS For use with SMD-20 and SMD-40 Power Fuses Item Spare Fuse-Unit End Fittings for use in SMD-20 Mountings, all styles except Station Inverted d For Fuse Unit Rated, kv, Nominal All Thinner for above one pint All FA From To Spare Fuse-Unit End Fittings for use in SMD-20 Mountings, Station Inverted style Spare Fuse-Unit End Fittings for use in SMD-40 Mountings, Station Vertical Style d Replacement Silencers for use in SMD-40 Mountings, Station Vertical Style 4.8 FA Includes Silencer. 1 Shelf life is one year from date of manufacture. RECOMMENDED HANDLING TOOLS For use with SMD-20 and SMD-40 Power Fuses Large Clampf Station Prong Item Distribution Prong 4416 Talon 4440 Universal Pole f For installing and removing fuse units in SMD-40 Power Fuse Mountings. l Select to match height of installation. Refer to Specification Bulletin R3 4402R2 l

15 LIVE PARTS For SM-4 and SM-5 Power Fuses Disconnect, 180 Opening Vertical PARTS For use with SM-4 and SM-5 Power Fuses RECOMMENDED HANDLING TOOLS For use with SM-4 and SM-5 Power Fuses Item Style For Fuse Mounting Type Locking Prong Disconnect 90 Opening Inverted SM Station Prong Universal Pole Item Spare Spring-and-Cable Assembly Pull-Ring Assembly for Holder, Disconnect, 180 Opening Vertical Pivot/Rain Shield Assembly for Holder, Disconnect, 180 Opening Vertical Rated (kv, Nominal) or 23 or 7.2 through 7.2 through 7.2 through 7.2 through d For use only in holders carrying an arrow-shaped nameplate. Springand-cable assemblies for holders which do not carry an arrow-shaped nameplate are no longer available so a new holder with the appropriate voltage rating must be ordered. Item For Fuse Type Disconnect 180 Opening Vertical and Disconnect 90 Opening Inverted For Holder SM SM-5 SM-5 (Parallel) Type SM-4 SM-5 SM-4 SM-5 SM-4 SM-5 SM-4 SM-5 SM-4 SM-5 SM-4 SM-5 SM-4 or SM R R3 Disconnect, 90 Opening Inverted SM R2 Select to match height of installation. Refer to Specification Bulletin FA-972 FA-2341d FA-973 FA-2342d FA-974 FA-2343d FA-975 FA-2344d FDA-10 FDA-10 FDA-1028 FDA R2 Page 15 of

16 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) SMD-20 Power Fuse Overhead Pole-Top Style Dimensions in inches (mm) kv Rating Nom. Max BIL a Page 16 of 1 Amps, Max Leakage Distance to Ground Minimum, Inches (mm) 11 (9) 17 (432) 17 (432) 12 (Complete Mounting Incl. Live Parts and End Fittings, less Connectors) 92122R3d 92142R3d 92123R3d 1 All SMD-20 Mountings are equipped with attachment hook to accommodate Loadbuster. 2 Connectors must be specified, refer to the table on page Dimension applies to mounting furnished with optional parallelgroove connectors (mounting catalog number suffix -D ). Dimension varies for mountings furnished with other connector arrangements. Dimensions in Inches (mm) A 1 A 2 M 1 M 2 P R 1 R 2 S3 12⁷ ₈ (3) 12⁷ ₈ (3) 13³ ₈ (340) Net Wt., Lbs. (Kg.) 6⁵ ₈ (168) 6⁵ ₈ (168) 5³ ₈ (137) 28⁵ ₈ (7) 28⁵ ₈ (7) 31¹ ₂ (800) 30 (762) 30 (762) 35¹ ₈ (892) 5¹ ₂ (140) 5¹ ₂ (140) 4⁷ ₈ (1) 21¹ ₂ (546) 21¹ ₂ (546) 22¹ ₈ (562) 14 (356) 14 (356) 15⁵ ₈ (397) 6⁷ ₈ (175) 6⁷ ₈ (175) 8¹ ₄ (210) 23 (10) (12) (11) a Also suitable for protection of single-phase-to-neutral circuits (lines or transformers) on 20/ GrY-kV systems. Or K amperes. d For provisions only for NEMA pad-terminal connectors or two-hole compression connectors, add suffix -G to catalog number.

17 SMD-20 Power Fuse Overhead Pole-Top Style Dimensions in inches (mm) kv 10¹ ₄ (260) 19 (483) 45¹ ₈ (1146) Rating Nom. Max BIL 3⁵ ₈ (92) Amps, Max 14³ ₄ (375) Leakage Distance to Ground Minimum, Inches (mm) 12 (Complete Mounting Incl. Live Parts and End Fittings, less Connectors) Net Wt., Lbs. (Kg.) ¹ ₂ (648) 944R3d 33 (15) 1 All SMD-20 Mountings are equipped with attachment hook to accommodate Loadbuster. 2 Connectors must be specified, refer to the table on page ¹ ₈ (587) 37 (940) Or K amperes. d For provisions only for NEMA pad-terminal connectors or two-hole compression connectors, add suffix -G to catalog number. Page 17 of

18 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) SMD-20 Power Fuse Station Vertical-Offset Style Dimensions in inches (mm) 1¹ ₂ () kv Rating Nom. Max BIL Page 18 of 8⁷ ₈ (2) 7 (178) ⁹ ₁₆ 1⁹ ₁₆ SLOTS (14 40) (Complete Leakage Mounting Incl. Live Parts and Distance End Fittings, less Connectors)12 to Ground Minimum, Cypoxy Porcelain Amps, Inches Station Post Station Post Max (mm) 15¹ ₂ (394) (610) 37 (940) ⁹ ₁₆ (14) DIA. HOLES ON 1 () CENTERS FOR kv ONLY 4 (102) NOTE: Terminal pads provided on both sides of fuse mounting R2-E R2-E 1904-E R R Dimensions in Inches (mm) A 1 A 2 B C F L M 1 M 2 N R 19⁷ ₈ (505) ³ ₄ (629) 30³ ₈ (772) 1 All SMD-20 Mountings are equipped with attachment hook to accommodate Loadbuster. 2 For available connector arrangements, refer to the table on page ¹ ₂ (368) 18¹ ₂ (470) 22¹ ₂ (572) 2 (51) ⁹ ₁₆ (14) DIA. HOLES ON 1³ ₄ (44) CENTERS SEE NOTE ⁷ ₈ (4) (711) (479) ¹ ₄ (356) (813) (565) (457) (1016) (711) ⁵ ₁₆ (8) Or K amperes. (610) 36³ ₈ (9) 43⁷ ₈ 18³ ₈ (467) 21⁷ ₈ (686) (1114) (556) 37 53⁷ ₈ ⁷ ₈ (940) (1368) (708) 4¹ ₂ (114) 5 (1) 6 (152) ¹ ₈ (3) ⁵ ₈ (702) 32⁵ ₈ (829) ¹ ₈ (968) Net Wt., Lbs. (Kg.) Cypoxy Station Post 60 () 77 (35) 98 (44) Porcelain Station Post 74 (34) 104 (47) 136 (62)

19 SMD-20 Power Fuse Station Inverted Style Dimensions in inches (mm) Rating Leakage Distance to Ground kv Minimum, Amps, Max Inches (mm) Nom. Max BIL 8⁷ ₈ 1¹ ₂ (2) () 7 (178) 15¹ ₂ (394) (610) 37 (940) ⁹ ₁₆ (14) DIA. HOLES ON 1 () CENTERS (Complete Mounting Incl. Live Parts and End Fittings, less Connectors)12 Cypoxy Station Post E E E ⁹ ₁₆ 1⁹ ₁₆ SLOTS (14 40) Porcelain Station Post ⁹ ₁₆ (14) DIA. HOLES ON 1³ ₄ (44) CENTERS 1 All SMD-20 Mountings are equipped with attachment hook to accommodate Loadbuster. 2 For available connector arrangements, refer to the table on page 12. 3¹ ₂ (89) Dimensions in Inches (mm) A 1 A 2 B C D F L M 1 M 2 N R 14³ ₈ 14¹ ₈ 10 17⁷ ₈ 17¹ ₄ 22 35⁵ ₈ 18³ ₈ (365) (359) (4) (635) (454) (4) (559) (905) (467) 18³ ₈ 18¹ ₈ ⁷ ₈ 20³ ₄ 26 43¹ ₈ 21⁷ ₈ (467) (460) (356) (737) (556) (5) (660) (1095) (556) 22³ ₈ 22¹ ₈ ⁷ ₈ 26³ ₄ 32 53¹ ₈ ⁷ ₈ (568) (562) (457) (889) (657) (679) (813) (1349) (708) Or K amperes. ³ ₄ (19) 4 22¹ ₈ (102) (562) 4¹ ₄ 26¹ ₈ (108) (664) 4¹ ₄ 30¹ ₈ (108) (765) Net Wt., Lbs. (Kg.) Cypoxy Porcelain Station Station Post Post 53 () 70 (32) 90 (41) 2 (51) 67 (30) 97 (44) 128 (58) Page 19 of

20 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) SMD-20 Power Fuse Station Right-Angle Style Dimensions in inches (mm) kv Rating Nom. Max BIL Page 20 of () 1 2¹ ₂ (64) 3 (76) ¹¹ ₁₆ (17) DIA. HOLES (4) Amps, Max 3 (76) Leakage Distance to Ground Minimum, Inches (mm) 15¹ ₂ (394) (610) 37 (940) 3¹ ₂ (89) 1 () (Complete Mounting Incl. Live Parts and End Fittings, less Connectors)12 Cypoxy Station Post R3-Ed R3-Ed R3-Ed 2¹ ₂ (64) 5 (1) 1¹ ₂ () 3 (76) Porcelain Station Post R3d R3d R3d 1 All SMD-20 Mountings are equipped with attachment hook to accommodate Loadbuster. 2 Connectors must be specified, refer to the table on page () Dimensions in Inches (mm) Net Wt., Lbs. (Kg.) A A B M M R R Station Post Station Post Cypoxy Porcelain ⁵ ₈ (549) ³ ₄ (654) 29¹ ₈ (740) ¹¹ ₁₆ (17) DIA. HOLES 3 (76) 1 () 17 (432) 20³ ₈ (518) 22¹ ₈ (562) 10 (4) 14 (356) 18 (457) 39¹ ₂ (1003) 46³ ₈ (1178) 54¹ ₈ (1375) Or K amperes. 35¹ ₄ (895) 41¹ ₂ (1054) 51¹ ₈ (1299) 30⁵ ₈ (778) 34³ ₄ (883) ¹ ₈ (968) 17⁵ ₈ (448) 20³ ₈ (518) (610) 50 (23) 60 () 72 (33) 64 (29) 87 (39) (50) d For provisions only for NEMA pad-terminal connectors or two-hole compression connectors, add suffix -G to catalog number.

21 SMD-40 Power Fuse Station Vertical Style Dimensions in inches (mm) 1¹ ₄ (32) 8⁷ ₈ (2) 7 (178) 5¹ ₄ (133) BASE DETAIL Rating Leakage Distance kv to Amps, Ground, Max Minimum, Inches Nom. Max BIL (mm) ¹ ₂ (394) 15¹ ₂ (394) (610) 1 () ⁹ ₁₆ (14) DIA. HOLES ON 1 () CENTERS ⁹ ₁₆ (14) 1⁹ ₁₆ (40) SLOTS 2 (51) 1³ ₄ (44) (Complete Mounting incl. Live Parts and End Fittings, less Connectors)123 Cypoxy Station Post 2 (51) Porcelain Station Post 3¹ ₈ (79) 1³ ₄ (44) ⁹ ₁₆ (14) DIA. HOLES TERMINAL PAD DETAIL (TOP AND BOTTOM) SP 12⁵ ₈ (321) SP 12⁵ ₈ (321) SP 16⁵ ₈ (422) 1 For available connector arrangements, refer to the table on page SMD-40 Live Parts are not available separately. 3 To specify optional Loadbuster Tool attachment hook, add suffix -LB to catalog number; e.g., LB. Mounting includes -kv -kv BIL Cypoxy station post insulators. 2 (51) Dimensions in Inches (mm) A 1 A 2 B C F L M R 13⁵ ₈ (346) 13⁵ ₈ (346) 17⁵ ₈ (448) 1⁷ ₈ (48) 10 (4) 10 (4) ¹ ₂ (648) 29 (737) 7³ ₁₆ (183) 19¹ ₄ (489) 22³ ₄ (578) 23¹ ₄ (591) 26³ ₄ (679) 36³ ₈ (9) ³ ₄ (984) 21³ ₈ (543) 21³ ₈ (543) 6¹ ₂ (165) 4³ ₈ (111) HINGE DETAIL Net Weight, Lbs. (Kg.) Cypoxy Station Post 65 (29) 70 (32) Porcelain Station Post 73 (33) 85 (39) 14 (356) 32¹ ₂ (826) 26¹ ₄ (667) 30¹ ₄ (768) 45¹ ₈ (1146) ³ ₈ (645) 85 (39) (50) f These dimensions are for mountings with -kv BIL Cypoxy station post insulators. Deduct 2¹ ₂ inches (64 mm) for mountings furnished with 95-kV BIL porcelain station post insulators; i.e., SP. Leakage distance to ground is 10¹ ₂ inches (267 mm) for mounting with porcelain station post insulators. Page 21 of

22 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) SM-4 and SM-5 Power Fuses Disconnect, 180 Opening, Vertical Style Dimensions in inches (mm) Type SM-4 SM-5 kv Nom. Max Page 22 of Rating Dimensions in Inches (mm) Net Weight, Lbs. (Kg.) Mounting12 Amps, Cypoxy BIL Max Station Post R1-E R1-E R1-E R1-E R2-E R2-E R2-E R2-E Porcelain Station Post R R R R R R R R2 Holder R R R R R2 A 1 A 2 B C F M 1 M 2 R X 12³ ₈ (314) 12³ ₈ (314) 16³ ₈ (416) 16³ ₈ (416) 20³ ₈ (518) 12³ ₈ (314) 12³ ₈ (314) 16³ ₈ (416) 16³ ₈ (416) 20³ ₈ (518) 1 Mounting includes live parts, less holder. For live parts furnished separately, refer to the table on page For available connectors, refer to the table on page Holder does not carry snuffler or silencer. 1¹ ₂ () 1¹ ₂ () 8⁷ ₈ (2) 7 (178) 1¹ ₄ (32) DIA. BASE DETAIL ⁹ ₁₆ (14) DIA. HOLES ON 1 () CEN- TERS ⁹ ₁₆ (14) 1⁹ ₁₆ (40) SLOTS 2 (51) Mounting includes -kv, -kv BIL Cypoxy station post insulators. 1³ ₄ (44) TO END OF HOLDER IN 180 OPEN POSITION 13¹ ₂ (343) 13¹ ₂ (343) 17¹ ₂ (445) 17¹ ₂ (445) 21¹ ₂ (546) 13¹ ₂ (343) 13¹ ₂ (343) 17¹ ₂ (445) 17¹ ₂ (445) 21¹ ₂ (546) 10 (4) (610) (4) (711) (356) (813) (356) (1016) (458) (1016) 10 (4) (610) (4) (711) (356) (813) (356) (1016) (458) (1016) 12¹ ₂ (318) 16¹ ₂ (419) 20³ ₄ (5) 28 (711) 28 (711) 12¹ ₂ (318) 16¹ ₂ (419) 20³ ₄ (5) 28 (711) 28 (711) 3¹ ₂ (89) FOR SM-4 5¹³ ₁₆ (148) FOR SM-5 ¹ ₂ (13) 13 TAPPED HOLES (TWO EACH SIDE) 30³ ₈ 15¹ ₂ (772) (394) 34³ ₈ 19¹ ₂ (873) (495) 42⁵ ₈ 23³ ₄ (1083) (603) 49⁷ ₈ 31 (1267) (787) 53⁷ ₈ 31 (1368) (787) 33⁵ ₈ 19⁵ ₈ (854) (498) 37⁵ ₈ 23⁵ ₈ (956) (600) 45⁷ ₈ ⁷ ₈ (1165) (708) 53¹ ₈ 35¹ ₈ (1349) (892) 57¹ ₈ 35¹ ₈ (1451) (892) ⁹ ₁₆ (14) 20³ ₄ (5) 20³ ₄ (5) ³ ₄ (629) ³ ₄ (629) 28³ ₄ (730) 21³ ₄ (552) 21³ ₄ (552) ³ ₄ (654) ³ ₄ (654) 29³ ₄ (756) 1³ ₄ (44) 5³ ₄ (146) 5³ ₄ (146) 5⁵ ₈ (143) 6 (152) 6 (152) 5³ ₄ (146) 5³ ₄ (146) 5⁵ ₈ (143) 6 (152) 6 (152) 2 (51) Cypoxy Porcelain Station Station Holder Post Post 50 (23) 56 () 72 (33) ( ) 90 (41) 54 () 60 () 76 (34) ( ) 94 (43) 57 (26) 70 (32) 99 (45) 105 (48) 128 (58) 61 (28) 74 (34) 103 (47) 109 (49) 132 (60) ⁹ ₁₆ (14) DIA. HOLES 3⁷ ₈ (98) FOR SM-4 4⁷ ₈ (1) FOR SM-5 All SM-4 Mountings in the Disconnect 180 Opening Vertical Style can be equipped with attachment hook to accommodate Loadbuster. Specify by adding suffix -LB to catalog number of mounting. 8.0 (3.6) 9.0 (4.1) 10.3 (4.6) 14.3 (6.5) 14.3 (6.5) 21.0 (9.5) 23.3 (10.5).8 (11.7) 31.8 () 31.8 () Mounting includes -kv BIL Cypoxy station post insulators. Deduct 2 inches (51 mm) from dimension of mountings equipped with porcelain station post insulators. Add ¹ ₂ inch (13 mm) to dimension of mountings equipped with porcelain station post insulators. 5¹ ₈ (130) FOR SM-4 5¹ ₂ (140) FOR SM-5

23 SM-5 Power Fuse Disconnect, 180 Opening, Vertical Style Dimensions in inches (mm) 1¹ ₂ () 1¹ ₂ () 8⁷ ₈ (2) 7 (178) 1¹ ₄ (32) DIA. ⁹ ₁₆ (14) DIA. HOLES ON 1 () CEN- TERS ⁹ ₁₆ (14) 1⁹ ₁₆ (40) SLOTS 5³ ₄ (146) 10 (4) ⁹ ₁₆ (14) DIA. HOLES ⁵ ₈ (16) 6 (152) 2 (51) 3 11¹ ₈ (76) (283) ⁹ ₁₆ (14) DIA. HOLES Rating Dimensions in Inches (mm) Net Weight, Lbs. (Kg.) kv Mounting12 Cypoxy Porcelain Amps, Cypoxy Porcelain Holder3 A B C F M Max 1 M Station Station 2 R Holder Nom. Max BIL Station Post Station Post Post Post E R3-E R R2 12¹ ₂ 10 12¹ ₂ 34 20¹ ₄ 22³ ₈ (318) (4) (610) (318) (864) (514) (568) () (41) (9.5) 720E R3-E R R2 12¹ ₂ ¹ ₂ ¹ ₄ 22³ ₈ (318) (4) (711) (419) (965) (616) (568) (41) (47) (10.5) 1 Mounting includes live parts, less holder. For live parts furnished separately, refer to the table on page 15. Mounting includes -kv, -kv BIL Cypoxy station post insulators. Two holders required with each mounting. 2 For available connectors, refer to the table on page 13. Deduct 2¹ ₂ inches (64 mm) from dimension of mountings equipped 3 Holder does not carry snuffler or silencer. with porcelain station post insulators. 3 (76) 1³ ₄ (44) 10 (4) ⁵ ₈ (16) Page 23 of

24 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) SM-5 Power Fuse Disconnect, 90 Opening, Inverted Style Dimensions in inches (mm) Page of 3³ ₄ (95) 1¹ ₂ () 1¹ ₂ () 1¹ ₄ (32) DIA. 1³ ₄ (44) ¹ ₂ (13) 13 TAPPED HOLES (TWO EACH SIDE) 3¹ ₄ (83) ⁹ ₁₆ (14) 1⁹ ₁₆ (40) SLOTS 7 8⁷ ₈ (2) (178) ⁹ ₁₆ (14) DIA. HOLES ON 1 () CENTERS 1³ ₄ (44) Rating Dimensions in Inches (mm) Net Weight, Lbs. (Kg.) kv Mounting12 Cypoxy Porcelain Nom. Max BIL Amps, Cypoxy Porcelain Holder3 A Max 1 A 2 B C F M Station Station R X Holder Station Post Station Post Post Post R2-E R R2 12³ ₈ 13¹ ₂ 10 12¹ ₂ 39³ ₈ 20⁷ ₈ 5³ ₄ (314) (343) (4) (610) (318) (1000) (530) (146) () () (10.7) R2-E R2-E R2-E R R R R R R R2 16³ ₈ (416) 16³ ₈ (416) 20³ ₈ (518) 12³ ₈ (314) 17¹ ₂ (445) 17¹ ₂ (445) 21¹ ₂ (546) 13¹ ₂ (343) 14 (356) 14 (356) 18 (458) 10 (4) 32 (813) 40 (1016) 40 (1016) 28 (711) 20³ ₄ (5) 28 (711) 28 (711) 16¹ ₂ (419) 51⁵ ₈ (1311) 62⁷ ₈ (1597) 62⁷ ₈ (1597) 43³ ₈ (2) ⁷ ₈ (632) ⁷ ₈ (632) 28⁷ ₈ (733) 20⁷ ₈ (530) 5⁵ ₈ (143) 6 (152) 6 (152) 5³ ₄ (146) 75 (34) ( ) 93 (42) 59 () 102 (46) 108 (49) 131 (59) 73 (33) 28.3 (12.8) 34.3 (15.5) 34.3 (15.5).8 (11.7) 1 Mounting includes live parts, less holder. For live parts furnished separately, Mounting includes -kv, -kv BIL Cypoxy station post insulators. refer to the table on page 15. Deduct 2 inches (51 mm) from dimension of mountings equipped with 2 For available connectors, refer to the table on page 13. porcelain station post insulators. 3 Holder does not carry snuffler or silencer. 5¹ ₈ (130) ⁹ ₁₆ (14) 2 (51) ⁹ ₁₆ (14) DIA. HOLES Printed in U.S.A.

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv) S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard

More information

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34. S&C Power Fuses s SM and SMLa Indoor Distribution (4.16 through 34. ) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set

More information

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13.

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS

More information

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv) Outdoor Distribution (4.4 kv through 46 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 50 apply, except as modified under WARRANTY QUALIFICATIONS

More information

SPECIFICATION BULLETIN

SPECIFICATION BULLETIN SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS on page 3. SPECIAL TO THIS PRODUCT:

More information

S&C Recloser Bypass Disconnects

S&C Recloser Bypass Disconnects S&C Recloser Bypass Disconnects Outdoor Distribution (14.4 kv through 34.5 kv) Application S&C Recloser Bypass Disconnects are station-type devices used to bypass and isolate automatic circuit reclosers

More information

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order S&C Alduti-Rupter Switchesa Indoor Distribution ( kv through kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 0 apply. SPECIAL TO THIS PRODUCT:

More information

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv) Outdoor Distribution (4.16 through 25 ) Specifications Conditions of Sale STANDAD: Seller s standard conditions of sale set forth in Price Sheet 153 apply, except as modified under WAANTY QUALIFICATIONS

More information

S&C Loadbuster Disconnects

S&C Loadbuster Disconnects S&C Loadbuster Disconnects Outdoor Distribution ( kv through 34.5 kv) With these outstanding features... Up to -ampere continuous ratings, 40,000-ampere RMS asymmetrical momentary ratings Designed for

More information

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale S&C Omni-Rupter Switches Outdoor istribution (14.4 kv and 5 kv) Specifications Conditions of Sale STNR: Seller s standard conditions of sale as set forth in Price Sheet apply. SPECIL TO THIS PROUCT: INCLUSIONS:

More information

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv) S&C Loadbuster Disconnect Switches Outdoor Distribution ( kv through 34.5 kv) S&C s Loadbuster Disconnect Switches, when used with S&C s Loadbuster tool, provide the ultimate in distribution live-switching

More information

Disconnect & ByPass Switches

Disconnect & ByPass Switches Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class

More information

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv TripSaver II Cutout-Mounted Recloser For enhanced lateral circuit protection at 15 kv and 25 kv Introducing s new TripSaver II Cutout-Mounted Recloser: A better solution for overhead lateral circuit protection

More information

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified

More information

Specifications. S&C Manual PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv)

Specifications. S&C Manual PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) Outdoor Distribution ( kv and kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WAR- RANTY QUALIFICATIONS

More information

Specif ications. Minimum Surge Arrester Rating, kv

Specif ications. Minimum Surge Arrester Rating, kv &C Fault amer Fuse Limiter Outdoor Distribution ( kv through kv) For Overhead Pole-op ransformers pecif ications Conditions of ale ADAD: eller s standard conditions of sale set forth in Price heet 0 apply.

More information

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401 February 26, 1976 Supersedes PL 38-640 dated October 15,1974 Pages 1-8 Prices effective April 29, 1974 Subject to change without notice Selling Policy 38-000 Mailed to E, D, C/1991, 2430/ PL Standard Bill

More information

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

T YPE MZ DISTRIBUTION S TANDARD CUTOUT T YPE MZ DISTRIBUTION S TANDARD CUTOUT Page 1 of 7 The Fuse Cutout type MZ was developed to operate in overhead distribution systems rated at 15, 27 and 38 kv grounded systems with 100 or 200 A nominal

More information

Specif ications. S&C Positrol Fuse Links. Outdoor Distribution

Specif ications. S&C Positrol Fuse Links. Outdoor Distribution S&C Positrol Fuse Links Outdoor Distribution Specif ications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: SPECIFICATION

More information

Specifications. S&C Source-Transfer PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) With Micro-AT Control. Conditions of Sale

Specifications. S&C Source-Transfer PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) With Micro-AT Control. Conditions of Sale Outdoor Distribution ( kv and kv) With Micro-AT Control Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WAR-

More information

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary 14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching

More information

S&C Type XS Fuse Cutouts

S&C Type XS Fuse Cutouts S&C Type XS Fuse Cutouts Outdoor Distribution 4.16 kv through 25 kv Application An Unexcelled Cutout S&C Type XS Fuse Cutouts, when fused with S&C Positrol Fuse Links provide full-fault-spectrum protection

More information

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Equipment Connection Bus Bar, or Grounded Metal Equipment Plate F Series Mounting Holes ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric

More information

TYPE BLT DISCONNECT SWITCHES

TYPE BLT DISCONNECT SWITCHES TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH

More information

S&C Type XS Fuse Cutouts

S&C Type XS Fuse Cutouts S&C Type XS Fuse Cutouts Outdoor Distribution (4.16 kv through 25 kv) S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection Descriptive Bulletin 351-30 August 25, 2003 Supersedes

More information

15 kv and 25 kv Thru-Bushings

15 kv and 25 kv Thru-Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 35 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

S&C Manual PME Pad-Mounted Gear

S&C Manual PME Pad-Mounted Gear S&C Manual PME Pad-Mounted Gear Outdoor Distribution,. kv and 5 kv S&C Manual PME Pad-Mounted Gear... Featuring Elbow-Connected Encased Components. S&C Manual PME Pad-Mounted Gear brings in-air insulation,

More information

25 kv Apparatus Bushings

25 kv Apparatus Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV Cutler Hammer SECTION PB-1A-110 PAGE 1 Replaces April, 1996 TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV The PSI/II Padmount is the second generation of switchgear in the PSI switchgear family. The PSI/II

More information

Catalog 14A January 2013

Catalog 14A January 2013 Catalog 14A January 2013 Page 1 January 2013 Type AR (Automation-Ready) Switch 14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt Description The Hubbell unitized Type AR switch is a distribution-level,

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 35 kv Separable Insulated Connector (elbow) Bus Bar or Other Component Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

INSTRUCTIONS Ç CAUTION. S&C Power Fuses Types SMD-1A, SMD-2B, SMD-2C, and SMD-3. For Field Assembly and Installation NOTE INSTRUCTION SHEET

INSTRUCTIONS Ç CAUTION. S&C Power Fuses Types SMD-1A, SMD-2B, SMD-2C, and SMD-3. For Field Assembly and Installation NOTE INSTRUCTION SHEET S&C Power Fuses Types SMD-1A, SMD-2B, SMD-2C, and SMD-3 Outdoor Transmission Mountings Rated 34.5, 46, and 69 kv INSTRUCTIONS For Field Assembly and Installation TABLE OF CONTENTS Section Page Number INTRODUCTION........................................1

More information

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Catalog 14B January 2015 HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch.

More information

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Fusing Equipment Catalog Data CA132035EN Supersedes November 2015 COOPER POWER SERIES UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Description Eaton has set a standard

More information

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution

More information

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.

More information

T HREE-SHOT TYPE MZR F USE CUTOUT

T HREE-SHOT TYPE MZR F USE CUTOUT T HREE-SHOT TYPE MZR F USE CUTOUT Page 1 of 7 D ESCRIPTION It is known that about 90% of the defects that occur in an air distribution system, are of a transient origin, i.e., are transient faults which

More information

S&C Circuit-Switcher Mark VI Outdoor Transmission (69 kv through 138 kv)

S&C Circuit-Switcher Mark VI Outdoor Transmission (69 kv through 138 kv) Outdoor Transmission (69 kv through 138 kv) Construction Guide This publication sets forth the data required for the user to design a support structure or pedestals for a Mark VI Circuit-Switcher; the

More information

INSTRUCTIONS For Field Assembly, Installation, and Maintenance

INSTRUCTIONS For Field Assembly, Installation, and Maintenance INSTRUCTIONS For Field Assembly, Installation, and Maintenance TABLE OF CONTENTS Section Page Number INTRODUCTION........................................1 ASSEMBLING AND INSTALLING MOUNTINGS............2

More information

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA

More information

Technical Specification For Outdoor Substation Harmonic Filter Banks

Technical Specification For Outdoor Substation Harmonic Filter Banks Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field

More information

The Standard Mounting Arrangements for S&C Alduti-Rupter Switches

The Standard Mounting Arrangements for S&C Alduti-Rupter Switches S&C Alduti-Rupter Switches Outdoor Distribution (14.4 kv through 69 kv) The Standard Mounting Arrangements for S&C Alduti-Rupter Switches Three-pole S&C Alduti-Rupter Switches for outdoor distribution

More information

INSTRUCTIONS Ç CAUTION Ç IMPORTANT

INSTRUCTIONS Ç CAUTION Ç IMPORTANT Type SM, SML, and SME j Indoor Distribution INSTRUCTIONS For Installation GENERAL Ç CAUTION The equipment covered by this publication must be selected for a specific application and it must be installed,

More information

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) S&C Fault Tamer Fuse Limiter Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

K-Limiter high ampere Companion II fuse

K-Limiter high ampere Companion II fuse Fusing Equipment Catalog Data CA132059EN Supersedes February 2016 COOPER POWER SERIES K-Limiter high ampere Companion II fuse General Eaton designs its Cooper Power series K-Limiter fuse to be conveniently

More information

M-Force three-phase switch

M-Force three-phase switch Supersedes K-SEC 926 December 2012 M-Force three-phase switch Description The M-Force switch from Eaton's Cooper Power Systems is a distribution-class, gangoperated, factory unitized three-phase overhead

More information

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 15 kv or 25 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles

More information

Cleaning Flooded Gear

Cleaning Flooded Gear S&C Manual PMX Modular Metal-Enclosed Switchgear Outdoor Distribution (13.8 kv and 25 kv) Cleaning Flooded Gear Table of Contents Section Page Section Page Introduction.... 2 Safety Information Understanding

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch Page 1 2015 Kinked roof prevents standing moisture Glass reinforced barriers meet NEMA GPO-3 Standards 0.625" diameter copper ground bar Elliott air-insulated bushings accept IEEE Standard inserts and

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Typical Specification

Typical Specification Engineered to Order Built to Last Typical Specification VAULT VRPFI, TWO POSITION, ROTARY PUFFER SWITCHGEAR PART 1- GENERAL 1.1 DESCRIPTION A. The switch shall consist of manually operated load interrupting,

More information

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12 Bulletin DB-104E12 Type RL-C Side Break Switch 7.2-69 kv 600-2000 A. CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Type RL-C

More information

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings Page 1 Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings I. General This specification covers the design requirements for a pad-mounted capacitor

More information

MDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D

MDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D MDS Dead-front Padmount Switchgear Style Guide 1VAM224804-SG May 2010 Revision D The MDS style guide aids in the proper selection of your style number. When ordering the MDS, the style number must be given

More information

Technical Specification for Pole Mounted Capacitor Rack

Technical Specification for Pole Mounted Capacitor Rack Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to

More information

TYPE V CENTER BREAK SWITCH

TYPE V CENTER BREAK SWITCH TYPE V CENTER BREAK SWITCH 3-PHASE, GROUP-OPERATED (SUBSTATION AND TRANSMISSION APPLICATIONS) *Available in Copper Horizontal upright, vertical or underhung mounting 15KV through 230KV 600A through 4000A

More information

M-Force three-phase switch

M-Force three-phase switch Switches and Disconnects CA008004EN Supersedes May 2015 COOPER POWER SERIES M-Force three-phase switch Description Eaton's Cooper Power series M-Force switch is a distribution-class, gang-operated, factory

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013 10AA Type C-Polymer Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all

More information

D-73P disconnect and bypass switches

D-73P disconnect and bypass switches Switches atalog Data 008005EN Supersedes pril 2016 OOPER POWER SERIES D-73P disconnect and bypass switches ontents Description Page D-73P disconnect switch....2 D-73P3 bypass switch....5 D-73P-D cutout

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014 10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,

More information

34-SDMS-01 SPECIFICATIONS FOR

34-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Description: Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies

More information

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General Page 1 STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General 1. Product The pad-mounted switchgear shall be in accordance with the applicable plans, drawings,

More information

Aluminum Vertical Break Switch kv A.

Aluminum Vertical Break Switch kv A. Bulletin DB-C106AA05 Type V2-CA Aluminum Vertical Break Switch 7.2-69 kv 600-2000 A. Designed for Simplicity V2-CA APPLICATION The Cleaveland/Price V2-CA is a three pole, group operated, aluminum vertical

More information

DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV

DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV TYPE PSE MANUAL DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV Figure 1 Federal Pacific Dead-Front PSE (available as UL Listed) contains an integrated system of fuses and switches with access control features

More information

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses Page 1 2016 EPMR-35-311S-R2/ESW-CM9 Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton s CPS LRTPs 50 Amp (Max) 27 kv Clip-Mounted NX Fuse Provisions 21.1/36.6 kv Grounded Wye Max Design, 150 kv

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High

More information

Mica Element Support. Compacted Quartz Sand. Length B

Mica Element Support. Compacted Quartz Sand. Length B Construction A Tin-Plated Brass Caps Dimensional Information for Trans-Guard s NOMINAL 5.5 Resin-Rich Filament Wound Glass/Epoxy Body 3 75 80 200 3 50 5 80 5 125 3 50 5 5 100 23.0 50 Low Current Interruption

More information

Outdoor Power Transmission & Distribution

Outdoor Power Transmission & Distribution Description: The purpose of the section is to highlight the current applicable UMCP Design Standards and requirements for Outdoor Power Transmission and Distribution, including but not limited to the following:

More information

RBA Catalog Numbers and Information

RBA Catalog Numbers and Information 50 RBA s and Information Type RBA Expulsion Fuses for Use Indoors or in an Enclosure Ampere Rating Standard Speed (Fuse Refills) Curve Reference 36-635 Time-Lag (Fuse Refills) Curve Reference 36-635 Approx.

More information

PT Medium voltage fuses for potential and small power transformers

PT Medium voltage fuses for potential and small power transformers Technical Data 6002 BUSSMANN Supersedes December 2017 SERIES PT Medium voltage fuses for potential and Description: Bussmann series Indicating and nonindicating E-Rated, current-limiting, medium voltage

More information

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 11-gauge steel equipment plate is rigid for easier elbow operation Parking stands for the upper two phases extend

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015 10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

Product Specifications for Aluminum Vertical Break Switches

Product Specifications for Aluminum Vertical Break Switches 1. General a) This specification covers the design, manufacture, and shipment of aluminum vertical break switches, both air-break and load-break configurations, for substation and transmission switching

More information

Figure 1. HX cutout fuseholders.

Figure 1. HX cutout fuseholders. Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus K-SEC 010 GENERAL Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted

More information

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER Solid Dielectric Load Break Switch SPECIFICATION 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED VACUUM LOAD INTERRUPTING

More information

INSTRUCTIONS Ç CAUTION. S&C Manual PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) For Installation TABLE OF CONTENTS

INSTRUCTIONS Ç CAUTION. S&C Manual PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) For Installation TABLE OF CONTENTS INSTRUCTIONS For Installation TABLE OF CONTENTS Section Page Number INTRODUCTION....................................... 1 INSPECTION AND HANDLING Packing.............................................. 3

More information

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015 10AA Type C-POLYMER Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all

More information

Figure 1. HX cutout fuseholders. Positive Interruption

Figure 1. HX cutout fuseholders. Positive Interruption Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus 327-10 general Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted to

More information

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break Part 1-GENERAL 1.1 DESCRIPTION Guide Specification Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break The switchgear shall consist of magnetically actuated solid dielectric insulated

More information

Copper Vertical Break Switch kv A.

Copper Vertical Break Switch kv A. Bulletin DB-106C05 Type V2-C Copper Vertical Break Switch 7.2-69 kv 600-2000 A. Designed for Simplicity V2-C APPLICATION The Cleaveland/Price V2-C is a three pole, group operated, copper vertical break

More information

Easy-On II Terminations

Easy-On II Terminations Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables, concentric neutral, metal tape shielded or wire shielded cables without need for additional

More information

JUMPERS & SWITCHING TOOLS

JUMPERS & SWITCHING TOOLS INSULATED JUMPER SETS 368 INSULATED JUMPER SETS FOR 15 KV, 25KV AND 35 KV Used for bypassing work areas when upgrading lines and when making temporary or emergency repairs Continuous-current ratings for

More information

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size. S&C Mini-Rupter es Indoor Distribution (4.16 kv through 25 kv) Selecting Standard Mounting Arrangements for Manually Operated Styles Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter

More information

PROTECTION AND CONTROL

PROTECTION AND CONTROL B C Table 1 DIMENSIONAL Information for Trans-Guard OS Fuses Fuse Voltage Rating (kv) 1/4-20 threaded hole 1/2 deep (both ends) Current Rating (Amps) Fuse Catalog Number 35 HTDS232035 Overall Diameter

More information

STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR

STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR A. General 1. Product The pad-mounted switchgear shall be PSI/II design as manufactured by Federal Pacific and shall conform

More information

Copper Double Break Switch

Copper Double Break Switch Bulletin DB-104DB09 Type DB-C Copper Double Break Switch 7.2 kv - 69 kv 600 A. - 2000 A. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 E-mail: sales@cleavelandprice.com Type DB-C

More information

Cleaning Flooded Gear

Cleaning Flooded Gear S&C Manual Metal-Enclosed Switchgear Indoor and Outdoor Distribution (4.16 kv through 34.5 kv) Cleaning Flooded Gear Table of Contents Section Page Section Page Introduction.... 2 Safety Information Understanding

More information

Volt Instrument Transformers

Volt Instrument Transformers www. kuhlman. com Kuhlman Electric Corporation Instrument Transformers 1 Table of Contents Description Model Page Wound, Oil-Filled VT (High Accuracy available) UTE-145-OH 3-4 Wound, Oil-Filled CCVT (High

More information

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 200 Amp Elliott air-insulated bushing wells accept IEEE Standard inserts and elbows ushing wells may be added or

More information

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B TCV2 Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com

More information

NX indoor current-limiting fuses

NX indoor current-limiting fuses Fusing Equipment Catalog Data CA132049EN Supersedes 240-60 September 2009 COOPER POWER SERIES NX indoor current-limiting fuses General Eaton provides overload protection for all indoor and underground

More information

Instructions for Installation and Operation

Instructions for Installation and Operation S&C Alduti-Rupter Switches Outdoor Distribution Three-Pole Vertical-Break Style Reciprocating Operating Mechanism 25/34.5 kv and 34.5 kv Instructions for Installation and Operation TABLE OF CONTENTS Section

More information