JUMPERS & SWITCHING TOOLS
|
|
- Kelly O’Brien’
- 6 years ago
- Views:
Transcription
1 INSULATED JUMPER SETS 368 INSULATED JUMPER SETS FOR 15 KV, 25KV AND 35 KV Used for bypassing work areas when upgrading lines and when making temporary or emergency repairs Continuous-current ratings for sets range from 200 to 400 amperes based on cable size selected Ampacity ratings are based on 90 C conductor temperature at 40 C ambient AWG size and voltage rating are marked on jacket Insulation and conductor screen meet and exceed ICEA-NEMA standard S Extra-flexible conductors are alloy-coated copperstranded rope per ASTM B-189 or B-33 NOTE: Adequate rubber gloves must be worn when installing or removing jumper clamps STANDARD 15KV JUMPER SETS WITH CLEAR HEADS (ONLY) 8 FT. 10 FT. 12 FT. 16 FT. 20 FT. #2 R8X#2-477 R10X#2-477 R12X#2-477 R16X#2-477 R20X# /0 R8X1/0-954 R10X1/0-954 R12X1/0-954 R16X1/0-954 R20X1/ /0 R8X2/0-954 R10X2/0-954 R12X2/0-954 R16X2/0-954 R20X2/ /0 R8X4/0-954 R10X4/0-954 R12X4/0-954 R16X4/0-954 R20X4/0-954 STANDARD 25KV JUMPER SETS WITH CLEAR HEADS (ONLY) 8 FT. 10 FT. 12 FT. 16 FT. 20 FT. 1/0 R8X1/ R10X1/ R12X1/ R16X1/ R20X1/ /0 R8X2/ R10X2/ R12X2/ R16X2/ R20X2/ STANDARD 35KV JUMPER SETS WITH CLEAR HEADS (ONLY) 8 FT. 10 FT. 12 FT. 16 FT. 20 FT. 1/0 R8X1/ R10X1/ R12X1/ R16X1/ R20X1/ /0 R8X2/ R10X2/ R12X2/ R16X2/ R20X2/ STANDARD 15KV JUMPER SETS WITH BRONZE 1.25 CLAMP R-BGC FT. 10 FT. 12 FT. 16 FT. 20 FT. #2 R8X#2-B125 R10X#2-B125 R12X#2-B125 R16X#2-B125 R20X#2-B125 1/0 R8X1/0-B125 R10X1/0-B125 R12X1/0-B125 R16X1/0-B125 R20X1/0-B125 2/0 R8X2/0-B125 R10X2/0-B125 R12X2/0-B125 R16X2/0-B125 R20X2/0-B125 4/0 R8X4/0-B125 R10X4/0-B125 R12X4/0-B125 R16X4/0-B125 R20X4/0-B125 STANDARD 25KV JUMPER SETS WITH BRONZE 1.25 CLAMP R-BGC FT. 10 FT. 12 FT. 16 FT. 20 FT. 1/0 R8X1/0-25-B125 R10X1/0-25-B125 R12X1/0-25-B125 R16X1/0-25-B125 R20X1/0-25-B125 2/0 R8X2/0-25-B125 R10X2/0-25-B125 R12X2/0-25-B125 R16X2/0-25-B125 R20X2/0-25-B125 STANDARD 35KV JUMPER SETS WITH BRONZE 1.25 CLAMP R-BGC FT. 10 FT. 12 FT. 16 FT. 20 FT. 1/0 R8X1/0-35-B125 R10X1/0-35-B125 R12X1/0-35-B125 R16X1/0-35-B125 R20X1/0-35-B125 2/0 R8X2/0-35-B125 R10X2/0-35-B125 R12X2/0-35-B125 R16X2/0-35-B125 R20X2/0-35-B125
2 REL-CJC-SERIES 35 kv JUMPER CLAMPS Insulated jumper clamps feature floatingwasher design and high-impact polyethylene handles with wide handguard flange Clear model allows for easy inspection Max amps continuous: 400 Install # 2 to 4/0 jumper cable Light & Strong (2.5 lbs. ea.) Bronze Body & Jaw 5/8-11 UNC thread Length: 11.5" FLEXIBLE INSULATED JUMPER CABLES Cable meets requirements of ASTM F2321. Flexible Insulated Jumper Cables are lightweight and resistant to oil, heat, moisture, ozone and abrasion. The cable is embossed every three feet with the conductor size and kv rating. All jumper cables use fine stranded conductor and a new EPR low temperature unipass orange CV cured jacket. The fine stranded copper conductor is alloy coated and assembled in a unidirectional rope lay for extra flexibility. The conductor has a semiconducting shield surrounding it to relieve voltage stress and improve dielectric strength and service life. 15kV JUMPER CABLE SIZE AWG CONTINUOUS CURRENT RATING, AMPERES 2754 # / / / kV JUMPER CABLE SIZE AWG CONTINUOUS CURRENT RATING, AMPERES / / kV JUMPER CABLE REL-CJC MCM (.162" to 1.25") REL-CJC MCM (.162" to.9") CABLE: #2-4/0 RATING: 35 kv Ø-Ø 2270 Orange Salcor Rubber 954 MCM (.162" to 1.25") Yellow Polyolefin 954 MCM (.162" to 1.25") 15kV 25kV 35kV 4/0 2/0 1/0 #2 1/0 2/0 1/0 2/0 JUMPERS & SWITCHING TOOLS JUMPER CLAMPS & CABLES SIZE AWG CONTINUOUS CURRENT RATING, AMPERES /
3 USJH-001 S16007 Insulated Hanger Conductor Range: #8 to 636 MCM ACSR For up to 1.25" dia. USJH JUMPER HOLDER Product Dimensions: 11" x 4.5" x.5" Weight: 6 oz Designed to eliminate jumper sag and prevent potential cross-phasing. Also minimizes swaying in windy conditions Fits over any class 2 or 3 line hose and exhibits a flash-over resistance of more than 50 kv. Multiple hooks safely cradle long jumpers in order to maintain positive control Installs easily with a gloved hand or shotgun stick and is made of a high visibility polymer that can handle the rigors of daily use even in cold temperatures S INSULATED HANGER Serves as convenient parking stand for linemen installing Jumper Clamps or Grounding Clamps on lines up to 34.5 kv 1-1/4" x 15" Epoxiglas pole provides the insulated section Bronze double stud fitting is 1/2" x 3-1/2" on each side 3477 & INSULATED JUMPER HOLDERS Designed to provide the lineman safety when installing and removing energized jumpers Allows linemen greater control with all jumping requirements Can be installed with all standard shotgun sticks or rubber gloves 3477 DESCRIPTION MAIN LINE RANGE WEIGHT " Fiberglass Shaft 1/2" Fiberglass Hanger Bar 6 Solid ACSR 1.9 lbs. JUMPER HOLDER & HANGERS Insulated 3484 Combination Jumper Extender / " Fiberglass Shaft 1/2" Fiberglass Hanger Bar 15" Fiberglass Shaft 3/8" Fiberglass Hanger Bar 6 Solid ACSR 2.5 lbs. 4 Solid ACSR 1.7 lbs INCH COMBINATION JUMPER EXTENDER / JUMPER HOLDER Extends the length of your existing mechanical jumpers Non-Conductive fiberglass shaft supports the weight of two jumpers while isolating the connection from other potentials Solid copper contact bar - 9" long x.625 diameter, exceeds 400 amp continuous current rating Eliminates the need for purchasing extra long jumpers - utilize two existing jumpers to double the operating length Can be used as a parking stand or ground jumper holder DESCRIPTION WEIGHT 3484 Combination Jumper Extender/Holder 2.75 lbs. 370
4 C LOAD-PICKUP TOOL FOR 15KV SYSTEMS Rated for loads as high as 250 amperes Fits #6 Copper through 795 kcmil ACSR Rubber gloves should be worn while installing Head has a floating washer to minimize conductor damage as jaws are installed Contacts are spring loaded and can be closed by pulling an insulated lanyard, putting the operator away from the tool during pickup operations Positive contact operation Tool cannot be used as a load-break tool as the operator cannot open the contacts while the tool is on the conductor Fiberglass rod attached to the end of the lanyard, used to recock the contacts Because it must be inserted through head of tool, lineman must remove tool from conductor before recocking Orange-tinted translucent Lexan housing permits easy visual inspection Nylon handguard is used to keep lineman s hand away from energized area By simply removing two screws in handguard, the tool can be disassembled for inspection and maintenance All current carrying parts are Cu or Cu alloy and contacts are silver plated Recommended 15kV jumper cables for this tool are #2 and 1/0 Load-Pickup Tool should be inspected or cleaned after 25 operations or 90 days Clean all plastic parts with a soft cloth, damp with ethyl alcohol only Electrical Ratings: Nominal 15kV 3-phase or 8.3kV single phase circuits; 250 amps continuous current Main Line Range: #6 Cu (0.162") min. through 795 kcmil ACSR (1.108") max. Contacts are opened by passing the recocking rod through head on tool and pushing plunger to fully opened position Operation cannot be completed when tool is connected to conductor C Load-Pickup Tool only Weight: 6.4 lbs. Closing the Contacts Recocking The Contacts JUMPERS & SWITCHING TOOLS LOAD-PICKUP TOOL SETS PRE-ASSEMBLED FOR 15KV SYSTEMS Include load-pickup device, jumper clamp, 15 kv cable Each completely assembled set consists of load-pickup tool, jumper clamp, 15 kv jumper cable and connectors. Refer to jumper cables, cable and connectors in this section Load-Pickup Tool and Jumper Clamp fit conductors from #6 Cu (0.162") through 795 ACSR kcmil (1.108") Customized pre-assembled sets are available from Reliable Equipment Load-Pickup tool cannot be used to break loads because operator cannot open contacts while tool is installed on conductor CABLE CABLE SIZE CONTINUOUS CURRENT WEIGHT C Feet #2 200 amps lbs. LPJ10X1/ Feet 1/0 250 amps lbs. C Feet 1/0 250 amps lbs. C Feet 1/0 250 amps lbs. ALL UNITS Electrical Ratings: Nominal 15kV 3-phase or 8.3kV single phase circuits. Jumper Clamp: #6 Copper (0.162 ) minimum through 795 kcmil ACSR (1.108 ) maximum Conductor Link LOAD-PICKUP TOOLS CONNECTOR LINK The Connector Link connects two insulated jumpers to create a longer jumper length. After the two clamps are connected to the link, the assembly can be wrapped with a small rubber insulating blanket. 371
5 SPECIFICATIONS 34.5 kv 69 kv Capacity 4,000 lb. 4,000 lb. Working range in in. Maximum take-up 12 in. 12 in. Insulation Max. 43 in. 51 in. Insulation Min. 31 in. 39 in. 43 in. 60 in. 66 in. TENSION PULLER HOOK ADAPTER Hook Adapter is a field replacement for adding catch and hotstick eye Adapter is interchangeable with hooks of both Tension Pullers above HOT STICK TENSION PULLER 34.5 KV Ø-Ø AND 69 KV Ø-Ø Equipped with rings for handling and operation with the Chance Grip-All Clampstick or with rubber gloves Both models have a non-swiveling hook on each end for positive hotstick operation Spring-loaded gate rotates 135 left or right from closed position Large, ratchet wrench selector lever easily accommodates hotsticks C Tension Puller Hook Adapter DESCRIPTION WEIGHT C kv, Safety Hook both ends 12 lbs. C kv, Safety Hook both ends 12.5 lbs. TIE BACK CLAMP Tie Back Clamp installs with a Grip-All clampstick Used with a Tension Puller to keep the tail of a conductor out of the work area by tying it back to the main line after it has been cut Clamp also may be used to hold a jumper on the main line while applying a compression connector C Tie Back Clamp Conductor Range: #4 to kcmil ACSR TENSION PULLERS 372 C Tension Puller Switching Tool Weight: 22 lbs. TENSION PULLER SWITCHING TOOL 35 KV Ø-Ø, 600 AMPS CONT, 150 KV BIL Tested per OSHA & ASTM F711 Tension Puller Switching Tool combines line-tension disconnect switch with Epoxiglas insulated tool as above Weathershed polymer skirts are bonded to 1-1/2"-dia. Pole Compression clamps secure switch hot parts to pole Bypass stud (1/2"-dia.) at each end of switch accepts 3"-wide jumper clamps Copper switch blade with silver-plated contacts opens to 90 or 180 with stop pin removed Galvanized hooks are provided for operation by loadbreak device With handling rings, may be operated by either hot-line tools or rubber-glove techniques Illustrated instructions give procedures for installation, operation and maintenance Fixed hooks on ends do not swivel Latch on hooks has a spring-loaded gate able to rotate 135 left or right from the closed position Selector lever on ratchet wrench is extra large for easier operation by hot line tools Hot line jumpers installed on conductor and bypass studs create parallel circuit Conductor is securely restrained before cut Long tail is clamped back onto itself Portable loadbreak device may be used to open switch For additional recommendations, refer to ANSI C37.35 IEEE Guide for the Application, Installation, Operation and Maintenance of High Voltage Air Disconnecting and Load Interrupter Switches NOTE: Specifications are same as for 34.5 kv unit above Operate disconnect switch only with a portable loadbreak tool.
6 BREAK-SAFE LOAD BREAK & PICK-UP TOOL The BREAK-SAFE is a jumper clamp that functions like a portable switch. It is designed to operate on overhead distribution lines from #6-954 ACSR (1.1") in conjunction with a mechanical jumper. The BREAK-SAFE has three operating functions: LOAD BREAK LOAD PICKUP CONTINUOUS CURRENT DUTY 300 AMPS MINIMUM SAFE DISTANCE In order to keep personnel at a safe distance, the BREAK-SAFE is operated with an insulated fiberglass hot stick for load break and load pick-up functions. The Yellow Safety Lock is also operated by a hot stick and helps prevent the tool from an unintended load break or pickup operation. USBS-15-1-PS USBS-15-2-PS USBS-27-1-PS USBS-27-2-PS USBS-46-1-PS USBS-46-2-PS DESCRIPTION 300 AMP 15 kv Loadbreak & Pickup Jumper Clamp w/ Floating Head 300 AMP 15 kv Loadbreak & Pickup Jumper Clamp w/ Duckbill Head 300 AMP 27 kv Loadbreak & Pickup Jumper Clamp w/ Floating Head 300 AMP 27 kv Loadbreak & Pickup Jumper Clamp w/ Duckbill Head 200 AMP 46 kv Loadbreak & Pickup Jumper Clamp w/ Floating Head 200 AMP 46 kv Loadbreak & Pickup Jumper Clamp w/ Duckbill Head USBS LOAD-RANGER XLT LOAD BREAK TOOL Introducing the industry s first portable switch fully rated from 7.2 kv to 27 kv at 600 amp for all three tool functions: LOAD BREAK LOAD PICKUP CONTINUOUS CURRENT DUTY The USBS is designed with a patent pending internal safety lock. If the tool is not reset the tool will not open. An external, manual locking pin keeps the tool either locked open or closed, until the operator is ready. This tool features durable electrical grade fiberglass housings and a glove friendly design. FEATURES Some of the unique patent pending features include an extra large clamp capable of handling all wire sizes up to nearly 2" diameter. Dual conductor bars allow the use of two mechanical jumper clamps which is needed to go above the typical 300 amp rating of mechanical jumpers. LOAD-RANGER XLT LOAD BREAK TOOL The arm attachment, counter mechanism and other key components are centrally located so the weight of the tool is aligned with the hot stick attachment giving the user maximum control. Has higher metal-to-metal clearance when fully extended, compared to the competition. This can reduce flash-over potential. The aluminum and fiberglass components are machined to very high tolerances and are designed for long life. Designed to be user friendly and simple to operate. The side reset button is easier than a plunger style and allows a lineman to keep their gloves on Low profile head enables our tool to reach switches that have animal guards installed. Our built-in counter is located in the body rather than the head allowing a smaller profile tool Numerous options including a Pad Mount version, hard case, soft case, extended insulated hood and an economical non-counter version. USLR-XLT-1 Floating Head Duckbill Head USBS JUMPERS & SWITCHING TOOLS LOAD BREAK TOOLS USLR-XLT -1 USLR-XLT -2 Maximum Voltage 27 kv 27 kv - 38 kv Maximum Amperage 900 AMP 900 AMP Counter Available Optional Optional Metal To Metal Clearance During Stroke (Flash-Over Resistance) 8.2" EST 12.2" EST USLR-XLT-2 373
7 LOAD BREAK TOOLS 5300R3 Loadbuster Loadbuster tools manufactured after March 2003 are equipped with a non-resettable Operation Counter that lets you monitor the use to make informed decisions with regard to inspection and maintenance of your tools. The Operation Counter is built into the silencer (NA-1073) and can be easily added to existing tools. S&C LOADBUSTER LOAD BREAK TOOL Available in two system-matched models 5300R3 14.4/25 kv nominal, 27 kv max. 5400R3 25/34.5 kv nominal, 38 kv max. Meets OSHA requirements for opening circuits under load with no external arc. Handles all live-switching duties transformers, lines, cables, and capacitors through 38 kv, 900 A Loadbuster s low-maintenance design stands up to the most demanding use up to 2000 operations between inspections Cuts installation and operation costs. No need for interrupters on each device simplified switching procedures minimize duration and scope of outages Loadbuster Tools are manufactured in accordance with a quality system certified to ISO 9001:2000. When used with suitably hook equipped disconnects, cutouts, power fuses, and pad-mounted gear the Loadbuster is able to perform the following liveswitching duties in single-phase or three-phase circuits of overhead distribution systems through 34.5 kv and underground distribution systems through 25kV. TRANSFORMER SWITCHING - transformer load currents up through 600 amperes maximum, as well as transformer magnetizing currents associated with the applicable loads. LINE SWITCHING - load splitting (parallel or loop switching) and load dropping of currents up through 600 amperes nominal, 900 amperes maximum; also line dropping (charging currents typical for distribution systems of these voltage ratings). CABLE SWITCHING - load splitting (parallel or loop switching) and load dropping of currents up through 600 amperes nominal, 900 amperes maximum; also cable dropping (charging currents typical for distribution systems of these voltage ratings). CAPACITOR BANK SWITCHING - Switching of single capacitor banks. ITEMS kv AMPS INTERRUPTING NOM. MAX. NOM. MAX. 5300R3 For Overhead Distribution Devices 14.4/ R3-E For Suitably Designed Pad-mounted Gear 14.4/ R3 For Overhead Distribution Devices 25/ Repair parts & service available from Reliable Equipment Loadbuster Case Included 374
8 TEMPORARY LOAD DISCONNECT TOOLS 8.3/15KV & 15/27KV APPLICATIONS* Available in two sizes Provides a temporary means of connecting and disconnecting equipment or circuits under load conditions Design does not have a fuse and does not provide protection for fault or overcurrent conditions Insulated bushing and hot parts are from Chance Type C-Polymer cutouts, including tubular-copper disconnect blade Arc-chute-type interrupter gives tool excellent loadbreak capability To interrupt load currents, device employs a stainless steel auxiliary blade within Delrin arc chute Tool simply clamps onto primary conductor with a Grip-All clampstick. Bronze stud at lower end accepts clamp on temporary tap jumper After closing tool blade, the permanent tap can be disconnected The load can then be dropped or reconnected by operating blade tool It should never be closed into a fault or opened during a fault OPERATION Self-contained loadbreak device operates by simple disconnect stick No special or portable tools are required to operate unit To break current, insert a disconnect stick into operating ring and rapidly open device When opening, spring-loaded auxiliary blade snaps out through the arc chute to elongate, cool and extinguish the confined arc Loadbreaking operation is independent of the disconnect stick speed To provide a clearly visible break, the disconnect blade hangs in approximately a vertical position Unfused or unswitched loads can be disconnected by first installing this tool and a temporary bypass jumper in parallel with permanent tap connection TEMPORARY LOAD DISCONNECT TOOLS Both models include protective carrying case. INSTALLATION & REMOVAL To install the tool, first remove its main blade Next, secure both clamps of suitable temporary jumper onto tap stud of tool s lower hinge Use Grip-All clampstick to install on main line conductor Use clampstick to secure one of the jumper clamps onto line with load to be picked up Use disconnect stick to place blade in lower hinge of tool Use disconnect stick in operating ring to close blade according to safe work procedures Take care when removing disconnect stick to avoid opening blade The equipment or circuit is now energized through the tool Before removing tool, first make up a permanent connection so there are two energizing paths Use a disconnect stick in the operating ring to open the blade according to safe work procedures and to remove blade from lower hinge of the tool Use a clampstick to take jumper clamp from conductor and secure it on tool stud Then use the clampstick to remove the tool from the main line conductor JUMPERS & SWITCHING TOOLS DISCONNECT TOOLS REPLACES DESCRIPTION DISCONNECT BLADE ARC-CHUTE ASSY. PSC C *8.3/15kV Temporary Load Disconnect Tool T730133T E P PSC C *15/27kV Temporary Load Disconnect Tool T730233T E P *For application on single-phase-to-neutral or three-phase solidly-grounded wye-connected circuits where recovery voltage does not exceed the max. design voltage of the device. 375
9 CUTOUT TOOLS 376 USJJ-001 Jack Jumper for 15 kv Cutout PSC Standard Type PSC Pivot-Lever Type TEMPORARY CUTOUT TOOLS FOR 15KV AND 27KV To provide fuse protection during live-line maintenance, temporary cutout tool simply clamps onto primary conductor with a Grip-All clampstick Brass stud at lower end accepts clamp on temporary tap jumper Insulated bushing and hot parts are from Chance Type C-Polymer cutouts Upper contact with integral sleet shield and hooks for operation by loadbreak tool and lower trunnion of cast bronze Fusetube must be fitted with fuselink rated no larger than 100 amps Available in ratings for 15kV and 27kV systems Tools come with or without a pivot-lever closing device STANDARD TYPE FUSE TUBE 100 AMPS CONTINUOUS CURRENT REPLACES CAT. NO. SYSTEM CLASS INTERRUPT CAPACITY WEIGHT FUSEHOLDER REPLACEMENT PSC C kV 10,000 Amps 7.25 lbs. T710112T PSC C kV 8,000 Amps lbs. T710211T STANDARD TYPE SOLID BLADE 300 AMPS CONTINUOUS CURRENT REPLACES CAT. NO. SYSTEM CLASS INTERRUPT CAPACITY WEIGHT FUSEHOLDER REPLACEMENT PSC C kV 12,000 Amps 8.25 lbs. T710133T PSC C kV 12,000 Amps lbs. T710233T REPLACES CAT. NO. PIVOT-LEVER TYPE SYSTEM CLASS INTERRUPT CAPACITY WEIGHT FUSEHOLDER REPLACEMENT PSC C kV 250 Amps 8.75 lbs. PSC C kV 250 amps lbs. ALL S INCLUDE CLAMP C AT TOP WITH THESE SPECS: MINIMUM MAIN LINE RANGE MAXIMUM TAP STUD #6 Sol. Cu. (0.162") 1033 kcmil ACSR (1.25") 1/2" diameter USJJ-001 & USJJ-002 JACK JUMPER CUTOUT BYPASS TOOL Safe and quick method to bypass an overhead cutout without the use of bulky jumper cables. The tool is indispensable for fuse coordination tasks and permits bypass of an underground dip. The Jack Jumper Cutout Bypass Tool saves time, eliminates risk of service interruption, and prevents accidental cross phasing. Includes soft case. USJJ-002 Jack Jumper for 27 kv Cutout GRAB-IT Cutout Fuse Tube Remover
Jumpers & Load Pickup Tools
Jumpers & Load Pickup Tools Catalog 2300 May 2016 Jumpers & Load Pickup Tools 2300 May 2016 Page 2301 All Chance Insulated Jumpers meet ASTM F 2321 Standard Specification. G4758 15kV 5 5 / 8 " G4765 25kV
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014
10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013
10AA Type C-Polymer Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all
More informationFigure 1. HX cutout fuseholders. Positive Interruption
Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus 327-10 general Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted to
More informationFigure 1. HX cutout fuseholders.
Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus K-SEC 010 GENERAL Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015
10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,
More informationBREAK-SAFE Load Break & Pick-up Tool
BREAK-SAFE Load Break & Pick-up Tool USBS-15-1-PS USBS-15-2-PS USBS-27-1-PS USBS-27-2-PS USBS-38-1-PS USBS-38-2-PS USBS-46-1-PS USBS-46-2-PS Available Options: H - Hard Case S - Soft Case Second Generation
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015
10AA Type C-POLYMER Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all
More informationT YPE MZ DISTRIBUTION S TANDARD CUTOUT
T YPE MZ DISTRIBUTION S TANDARD CUTOUT Page 1 of 7 The Fuse Cutout type MZ was developed to operate in overhead distribution systems rated at 15, 27 and 38 kv grounded systems with 100 or 200 A nominal
More informationDisconnect & ByPass Switches
Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class
More informationBREAK-SAFE Load Break & Pick-up Tool
BREAK-SAFE Load Break & Pick-up Tool USBS-15-1-PS USBS-27-1-PS USBS-46-1-PS USBS-15-2-PS USBS-27-2-PS USBS-46-2-PS Available Options: H - Hard Case S - Soft Case Second Generation Models Only. For tools
More informationS&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv
TripSaver II Cutout-Mounted Recloser For enhanced lateral circuit protection at 15 kv and 25 kv Introducing s new TripSaver II Cutout-Mounted Recloser: A better solution for overhead lateral circuit protection
More informationCHANCE NEW ADDITIONS
CHANCE NEW ADDITIONS h u b b e l l p o w e r s y s t e m s. c o m CHANCE 2017 NEW ADDITIONS ABS Pole Covers Added January 2017 In-line Rubber Blanket Clamp Added June 2017 ASTM 5H and 6H Rated Cluster
More informationSTRAIN LINK STICK ROLLER LINK STICK ADJUSTABLE STRAIN POLES SPIRAL LINK STICK TRANSMISSION TOOLS
172 Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com STRAIN LINK STICK Used as insulation between rope blocks and a hot line wire grip For deadend structures and running corners Attached to conductor
More informationSpecifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)
S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard
More informationCutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526
Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526 Section 10A 10A-1 Warranty - Material Hubbell Power Systems, Inc. warrants all products sold
More informationTEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES
TEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES TEMPORARY PROTECTIVE GROUNDING EQUIPMENT ACCESSORIES J-2 Grounding Equipment Accessories. www.salisburybyhoneywell.com BALL & SOCKET SYSTEM BALL STUDS
More informationHUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary
Catalog 14B January 2015 HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch.
More informationType M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary
14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching
More informationCatalog 14A January 2013
Catalog 14A January 2013 Page 1 January 2013 Type AR (Automation-Ready) Switch 14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt Description The Hubbell unitized Type AR switch is a distribution-level,
More informationMechanical Hoists. Catalog 1100 July Hoists - Mechanical Phone: Web: hubbellpowersystems.
Mechanical Hoists Catalog 1100 Page 1101 RATCHET HOISTS User-friendly operation and construction. Experienced operators prefer CHANCE lever hoists for longterm, dependable performance. Light-weight for
More informationS&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)
S&C Loadbuster Disconnect Switches Outdoor Distribution ( kv through 34.5 kv) S&C s Loadbuster Disconnect Switches, when used with S&C s Loadbuster tool, provide the ultimate in distribution live-switching
More informationJumpering and grounding equipment and assemblies
Supersedes 325-50 July 2014 Jumpering and grounding equipment and assemblies Contents Description Page Jumpering Equipment Load Pickup Clamps... 2 Jumper Clamps.... 3 Jumper Components.... 4 C-Type Grounding
More informationS&C Loadbuster Disconnects
S&C Loadbuster Disconnects Outdoor Distribution ( kv through 34.5 kv) With these outstanding features... Up to -ampere continuous ratings, 40,000-ampere RMS asymmetrical momentary ratings Designed for
More informationTransmission Tools. Catalog 2250 May Transmission Tools Phone: Web: hubbellpowersystems.
Transmission Tools Catalog 2250 May 2016 Transmission Tools 2250 May 2016 Page 2251 STRAIN LINK STICK Tested per OSHA & ASTM F711 Used as insulation between rope blocks and a hot line wire grip For deadend
More informationType L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description
Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution
More informationNOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice.
CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is defined in
More informationElectronic Resettable Sectionalizer
POWER SYSTEMS, INC. Protected by U.S. Patents No. 5,612,661; 4,935,715; DES. 278,331 and other patents pending Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable
More informationS&C Type XS Fuse Cutouts
S&C Type XS Fuse Cutouts Outdoor Distribution 4.16 kv through 25 kv Application An Unexcelled Cutout S&C Type XS Fuse Cutouts, when fused with S&C Positrol Fuse Links provide full-fault-spectrum protection
More informationwww. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003
Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under
More informationTYPE V CENTER BREAK SWITCH
TYPE V CENTER BREAK SWITCH 3-PHASE, GROUP-OPERATED (SUBSTATION AND TRANSMISSION APPLICATIONS) *Available in Copper Horizontal upright, vertical or underhung mounting 15KV through 230KV 600A through 4000A
More informationUltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout
Fusing Equipment Catalog Data CA132035EN Supersedes November 2015 COOPER POWER SERIES UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Description Eaton has set a standard
More informationS&C Manual PME Pad-Mounted Gear
S&C Manual PME Pad-Mounted Gear Outdoor Distribution,. kv and 5 kv S&C Manual PME Pad-Mounted Gear... Featuring Elbow-Connected Encased Components. S&C Manual PME Pad-Mounted Gear brings in-air insulation,
More informationSpecifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)
Outdoor Distribution (4.16 through 25 ) Specifications Conditions of Sale STANDAD: Seller s standard conditions of sale set forth in Price Sheet 153 apply, except as modified under WAANTY QUALIFICATIONS
More informationPRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT
PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze
More informationBRACKETS, MOUNTS & HARDWARE
HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,
More informationManufacturer of HOT LINE TOOLS. Phone:
Manufacturer of HOT LINE TOOLS Phone: 828-323-8914 NEW PRODUCTS 2017 Tail Tamer Temporary Conductor Clamp P 24 Conductor Lift Snatch Block P 26 Padmount Hex Adapter Set P 32 BLUE STRIPE Take-Apart Hot
More informationProduct Specifications for Aluminum Vertical Break Switches
1. General a) This specification covers the design, manufacture, and shipment of aluminum vertical break switches, both air-break and load-break configurations, for substation and transmission switching
More informationPower & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment
Use load interrupter attachments to enable loop sectionalizing, line dropping, load breaking and transformer-magnetizing current interruption. Increase the capability of your disconnect switches by adding
More informationManufacturer of HOT LINE TOOLS. Phone:
Manufacturer of HOT LINE TOOLS Phone: 828-323-8914 Utility Solutions was founded in 1990. We design and manufacture hot line tools and products for the electric power industry. We are Lineman driven. Our
More informationMechanical Hoists. NOTICE: For latest revision of our Catalog and Literature, please visit our web site:
Section 1101 1100 Mechanical Hoists Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is defined in the Uniform Commercial Code) and to be
More informationCPCS the U.S.A.
Clampsticks "AKA" Shotgun Sticks feature a high quality foam filled fiberglass reinforced plastic tube providing maximum insulation and mechanical strength. They are lightweight and easy to handle. Feature
More informationS&C Type XS Fuse Cutouts
S&C Type XS Fuse Cutouts Outdoor Distribution (4.16 kv through 25 kv) S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection Descriptive Bulletin 351-30 August 25, 2003 Supersedes
More informationM-Force three-phase switch
Supersedes K-SEC 926 December 2012 M-Force three-phase switch Description The M-Force switch from Eaton's Cooper Power Systems is a distribution-class, gangoperated, factory unitized three-phase overhead
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationGrounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents
Temporary Connections CA325004EN Supersedes November 2016 Grounding equipment COOPER POWER SERIES Contents Description Page Grounding elbow products... 2 Grounding elbow and kit product ratings... 5 200
More informationPower Fuses. > Power Fuses > BPA & HPA kv AMPs
The equipment described in this bulletin performs in accordance with NEMA standards publication SG2-1954, paragraphs SG2-5, SG2-5.10, and SG2-5.11 TYPE BPA Power Fuses 7.2-161 kv 100-200-300 400 AMPs The
More informationGROUP D. Switch & Protective device.
GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated
More informationSpecifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)
Outdoor Distribution (4.4 kv through 46 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 50 apply, except as modified under WARRANTY QUALIFICATIONS
More information15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch
Page 1 2015 Kinked roof prevents standing moisture Glass reinforced barriers meet NEMA GPO-3 Standards 0.625" diameter copper ground bar Elliott air-insulated bushings accept IEEE Standard inserts and
More informationS&C Recloser Bypass Disconnects
S&C Recloser Bypass Disconnects Outdoor Distribution (14.4 kv through 34.5 kv) Application S&C Recloser Bypass Disconnects are station-type devices used to bypass and isolate automatic circuit reclosers
More informationCall Toll Free GO ALTEC
presents A.B. Chance Call Toll Free 9002-00013 09/05 A. B. CHANCE Company Mechanical Hoists...........................................................p 3 Powered Hoists...........................................................p
More informationRBA Catalog Numbers and Information
50 RBA s and Information Type RBA Expulsion Fuses for Use Indoors or in an Enclosure Ampere Rating Standard Speed (Fuse Refills) Curve Reference 36-635 Time-Lag (Fuse Refills) Curve Reference 36-635 Approx.
More information10DD 10DD-1. Section CAUTION:
POLYMER Electronic Resettable Sectionalizer Protected by U.S. Patents No. 6,593,842; 5,854,582; 5,612,661; 4,935,715; 4,795,996; and other patents pending Section 10DD-1 10DD Warranty - Material Hubbell
More information600 A 15 kv class T-OP II deadbreak connector
Deadbreak Apparatus Connectors CA650017EN Supersedes 600-12 February 2010 COOPER POWER SERIES 600 A 15 kv class T-OP II deadbreak connector General Eaton terminates high-voltage underground cable to transformers,
More informationTools and Equipment For Live Line Working
Tools and Equipment For Live Line Working Table of Contents Product Slot Together Switching Rods 5 Switching Rod Bags 5 Telescopic Rods For Transmission 5 Take-Apart Hot Sticks Telescopic 6 Telescopic
More information3.0OVERHEAD TRANSMISSION SWITCHES
HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 3 Overhead Transmission Switches CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,
More informationINSTALLATION PRODUCTION TESTS
Deadbreak Apparatus Connectors 600 A 15/25 kv Class Bol-T Deadbreak Connector Electrical Apparatus 600-10 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class Bol-T Deadbreak Connector is used to terminate
More informationEasy-On II Terminations
Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables, concentric neutral, metal tape shielded or wire shielded cables without need for additional
More informationProduct Specifications for Phase Over Phase GOABS(r)
1. General a) This specification covers the design, manufacture, and shipment of phase-over-phase, 1-way, 2-way, 3-way, and 4-way, gang-operated disconnecting switches, both air-break and load-break, for
More informationSPECIFICATION BULLETIN
SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS on page 3. SPECIAL TO THIS PRODUCT:
More information600 A 35 kv class BT-TAP deadbreak connector
Supersedes 600-55 July 2014 600 A 35 kv class BT-TAP deadbreak connector General Eaton's Cooper Power Systems 600 A 35 kv Class BT-TAP deadbreak connector is used to terminate high-voltage underground
More information600 A 15 and 25 kv class Cleer grounding elbow
Loadbreak/Deadbreak Connectors CA650013EN Supersedes March 2015 COOPER POWER SERIES 600 A 15 and 25 kv class Cleer grounding elbow General Eaton provides a visible ground on its Cooper Power series 600
More informationSpecifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.
S&C Power Fuses s SM and SMLa Indoor Distribution (4.16 through 34. ) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set
More informationUnderground Distribution Switchgear
Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationTYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV
Cutler Hammer SECTION PB-1A-110 PAGE 1 Replaces April, 1996 TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV The PSI/II Padmount is the second generation of switchgear in the PSI switchgear family. The PSI/II
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationM-Force three-phase switch
Switches and Disconnects CA008004EN Supersedes May 2015 COOPER POWER SERIES M-Force three-phase switch Description Eaton's Cooper Power series M-Force switch is a distribution-class, gang-operated, factory
More informationGrounding Equipment. Catalog 3000 March Grounding Equipment 3000
Grounding Equipment Catalog 3000 March 2013 March 2013 Page 3001 Safe Working Practices There are many reasons for temporary grounding to protect personnel working on de-energized circuits, including:
More informationNOW WHAT? HV JUICE. Tappat 3 Way LV Link Pillar. Oct/Nov This Issue. All the solutions for Temporary. Earthing and Equipotential Bonding
HV JUICE Oct/Nov 2017 NOW WHAT? All the solutions for Temporary Earthing and Equipotential Bonding This Issue Tappat 3 Way LV Link Pillar PAGE 6 THE EQUIPOTENTIAL BONDING ZONE PAGE 2 MV EARTH SETS PAGE
More informationTests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50
Deadbreak Apparatus Connectors 600 A 35 kv Class Bol-T Deadbreak Connector Electrical Apparatus 600-50 General The Cooper Power Systems 600 A, 35 kv Class Bol-T Deadbreak Connector is used to terminate
More informationTechnical Specification for Pole Mounted Capacitor Rack
Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to
More informationType ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB
Type ICX Interchangeable Cutout 15-38 kv Outdoor Distribution Cutout Product Bulletin 1VAG271201-DB Product Features 15, 27, or 38 kv 110, 125, 150, 180, or 200 kv BIL 100 A, 200 A Fused 300 A Disconnect
More informationElastimold & Hi-Tech Fuse Products
In this section... Elastimold & Hi-Tech Fuse Products Elastimold & Hi-Tech Fuse Products Overview...H-62 Elastimold Fused Loadbreak Elbows (FLE)... H-63 H-67 Elastimold Molded Current-Limiting Fuses (MCLF)...
More informationCOOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN
Switches MN008004EN Effective April 2016 Supersedes S328-10-1 June 2013 COOPER POWER SERIES UltraSIL polymer-insulated D-73P disconnect switches installation instructions DISCLAIMER OF WARRANTIES AND LIMITATION
More informationDO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.
DO-III DO-III Fuse Holder TPL 44-835, May 2000, Page 1 of 4 General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder ABB Inc. General Description The ABB DO-III fuse holder is a draw
More informationOperators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features
Vertical Break Switch Operators/Accessories Ordering Information Furnish: Switch type Voltage Amperage Momentary rating BIL level Mounting position Operator type Accessories required Base mounting holes
More informationTYPE BLT DISCONNECT SWITCHES
TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH
More informationPublication No.: PSG
TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06
More information25 kv class fused loadbreak elbow connector
Loadbreak Connectors Catalog Data CA650070EN Supersedes 500-111 July 2012 COOPER POWER SERIES 25 kv class fused loadbreak elbow connector General Eaton combines a fully-shielded and insulated plug-in termination
More informationT HREE-SHOT TYPE MZR F USE CUTOUT
T HREE-SHOT TYPE MZR F USE CUTOUT Page 1 of 7 D ESCRIPTION It is known that about 90% of the defects that occur in an air distribution system, are of a transient origin, i.e., are transient faults which
More informationUnderground Distribution Switchgear
Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,
More informationCOOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN
Fusing Equipment MN132011EN Effective January 2016 Supersedes KS1.1-01-1 May 2003 HX-CB loadbreak fuse cutout installation instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY
More informationFigure 1. Kearney Type HX cutout.
Fusing Equipment Kearney Open Distribution Cutouts Type HX Installation Instructions Service Information KS010-01-1 CONTENTS Product Information...........................1 Safety Information............................2
More informationCOOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN
Fusing Equipment MN132010EN Effective February 2016 Supersedes S240-64A-1 October 1998 COOPER POWER K-Limiter back-up current-limiting fuse installation instructions SERIES DISCLAIMER OF WARRANTIES AND
More informationSECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS
CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION 100 KVA AND LARGER (CONCRETE PADS ONLY) 27.05-01 CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION
More informationLoadbreak Apparatus Connectors
Loadbreak Apparatus Connectors 200 A 25 kv Class POSI-BREAK Loadbreak Elbow Connector with Optional Integral Jacket Seal* Electrical Apparatus 500-29-7 general The POSI-BREAK Loadbreak Elbow Connector
More informationPSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.
Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.
More informationPRODUCTS FOR THE RAIL AND UTILITY INDUSTRY
PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY connectorproducts.com 1300 John Tipton Blvd. Pennsauken, NJ 08110 Phone: 856.829.9190 Fax: 856.829.9195 Catalog IX.1 American Design American Made Our success
More informationPOWER SYSTEMS, INC. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS
CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBITIONS Warranty - Material Chance warrants all products sold by it to be merchantable (as such term is defined in the Uniform Coercial
More informationCOOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing
Fusing Equipment MN132028EN Effective November 2016 Supersedes June 2012 (S240-66-1) COOPER POWER SERIES ELF Current-Limiting Dropout Fuse Installation Instructions Pull ring Housing Lifting eye Identification
More informationCopper Double Break Switch
Bulletin DB-104DB09 Type DB-C Copper Double Break Switch 7.2 kv - 69 kv 600 A. - 2000 A. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 E-mail: sales@cleavelandprice.com Type DB-C
More informationInstruments and Meters
Instruments and Meters Catalog 2450 July 2018 I nstruments and Meters 2450 July 2018 Page 2451 Single-Range Units For convenience on different systems, toggle on dual-range units can switch calibration
More informationS&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)
S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles
More informationAluminum Vertical Break Switch kv A.
Bulletin DB-C106AA05 Type V2-CA Aluminum Vertical Break Switch 7.2-69 kv 600-2000 A. Designed for Simplicity V2-CA APPLICATION The Cleaveland/Price V2-CA is a three pole, group operated, aluminum vertical
More informationOVERHEAD DISTRIBUTION SWITCHES
OVERHEAD DISTRIBUTION SWITCHES 0800 442 182 www.transnet.co.nz CONTENTS LineBOSS 15kV - 35kV Sidebreak GOAB Switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 LineBOSS Selection
More information15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses
Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA
More informationDRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.
DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,
More informationThree-Phase Pole Mounted Recloser
Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE
More information