Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB
|
|
- Kristina Griffin
- 5 years ago
- Views:
Transcription
1 Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB
2 Product Features 15, 27, or 38 kv 110, 125, 150, 180, or 200 kv BIL 100 A, 200 A Fused 300 A Disconnect Blade Porcelain, Silicone, or Polymer Concrete Insulators Available Seacoast Design ECD (Emission Control Device) Cutout/Arrester Combo Kick-out Spring Description The ABB ICX interchangeable cutout is used on overhead distribution systems to provide overcurrent protection and visible indication of fuse operation. The ICX provides a visible break sectionalizing point for maintenance personnel and is equipped with hooks to use with a portable loadbreak tool. This allows the ICX to be used as a loadbreak switch to open the circuit with load current flowing. Silicone or Polymer Concrete insulators, Emission Control Devices (ECDs), Seacoast design, cutout/arrester combinations, and Autolink options are available on certain models. s The ICX cutout is offered in three frame sizes and five BIL ratings. Each of the frames accommodates fuseholders with various ratings. ICX ratings are 110 kv through 200 kv BIL. Application The ICX 100 A fuse is provided with a moisture proof tube as a standard offering. Cutouts perform by expelling gases during interruption from the bottom of the fuse tube. For the highest interrupting rating, a link extender rod is attached to the fuse tube cap, improving the efficiency of gas expulsion and arc interruption. Fuse tubes with more than one rating are clearly labeled to indicate each interrupting capability. This minimizes the number of styles that must be stocked, while providing the broadest range of application flexibility. Interchangeability The ICX cutout is designed to be electrically and mechanically interchangeable with the S&C type XS, A.B. Chance type C, and Cooper type L cutouts. Fuseholder caps are also interchangeable with the S&C design. Testing has confirmed the performance of the ICX fuseholder and fuse support with S&C and Chance. ICX cutout with arrester combination Standards and Design Testing The ICX cutout meets or exceeds all applicable requirements of EEI, NEMA SG , and ANSI C and C standards. 15 kv ICX polymer concrete ICX with ECD - 2 -
3 Options Silicone Rubber Silicone rubber has been used for more than 25 years as an outdoor insulation material and has become the fastest growing choice for polymeric material for medium and high voltage outdoor insulation. Silicone was selected for its superior performance, durability, and insulation properties. It has the unique ability to maintain its hydrophobicity and offers greater stability against heat and ultraviolet radiation compared to other polymers. In addition, cutouts are 30% - 50% lighter than units. Silicone insulators are available in all ratings up to 180 kv BIL. Polymer Concrete ABB has been using polymer concrete for more than 10 years. It is available in the 110 and 125 kv BIL ratings. Polymer concrete provides a safe, shatter-proof design with molded-in rods to prevent moisture penetration. Polymer concrete is cold weather friendly since it resists damage from freeze/thaw cycles. This makes it an excellent replacement for in colder climates. It is a field-proven material that provides excellent electrical properties and dielectric strengths, as well as superior mechanical durability. ICX with ECD The ICX is available with an Emission Control Device (ECD). The ECD prevents forest fires and provides added operator and environment protection. The unlatching operation of the dropout is unique in the ECD, as it automatically resets to the service position upon closing the dropout carrier. Kick-out Spring All ICX fuse tubes are available with an optional kick-out spring. The spring assists the drop-out operation by increasing the kick-out force on the tube. Construction Details Fuse Tube Construction The ICX cutouts utilize two different types of fuse tubes: a moisture-proof fuse tube or a high-strength glass fuse tube. The moisture proof fuse tube is standard on all 100 A designs and is notated by the letter "M" in the 8th digit of the style number (refer to Ordering Instructions on pages 6-7). The moisture-proof tube reduces swelling that can create problems with interruption. The 200 A design utilizes a high-strength glass fuse tube and is notated by the letter "A" in the 8th digit of the style number (refer to Ordering Instructions on pages 6-7). This fuse tube is composed of a horn fiber liner surrounded by a glass filament wound outer shell. The durable tube withstands the rigors of high fault current interruptions. In addition, the tube is applied with electrostatic powder paint to provide protection against the effects of ultraviolet rays. Voltage Levels Single voltage rated cutouts can be applied on any single or three-phase system where the line-to-line voltage does not exceed the cutout rating. Dual voltage rated cutouts are suitable on single-phase circuits where maximum line-to-ground voltage does not exceed the value shown to the right of the slash (for example, does not exceed 27 kv in 15/27 kv). ICX cutouts may be used on three-phase circuits that are solidly grounded and the maximum line-to-line voltage does not exceed the value shown to the left of the slash (for example, does not exceed 7.8 kv in 7.8/15 kv). Each frame size has fault interrupting ratings at more than one voltage level. An extensive testing program was performed to develop these multi-voltage capabilities. As a result of this program, the voltage rating of some ICX cutouts may be increased by changing the fuseholder. 27 kv ICX with Autolink 27 kv Silicone ICX with 300 A blade (600 mm creep) 15 kv ICX kv Silicone ICX (180 kv BIL)
4 Unit Dimensions A B 2.25 [57].312 NEMA "A" BRKT.375 NEMA "B" BRKT [76-102] C [ ] 7.75 [197] 1.56 [40] F R D DEG 1.00 [25] E Note: Metric dimensions are displayed in [mm]. kv BIL Unit Dimensions (in) Creep* Weight* Class (kv) A B C D E F R (in) (lb) or or BIL Unit Dimensions (mm) Creep* (kv) A B C D E F R (mm) kv Class Weight* (kg) or or * Creep and weight values are for standard units
5 Bracket Dimensions.312 [8].375 [10] 7.8 [198] 7.8 [198] 1.6 [40] 1.6 [40] 2.6 [67] 2.6 [67] NEMA A bracket NEMA B bracket.38 [10] 7.8 [198] 12.8 [325] 9.1 [231] 1.5 [38] 5.4 [137] 6.9 [175] 2.2 [56] Extended bracket Pole Mounting bracket Part numbers listed on page 8. Note: Metric dimensions are displayed in [mm]
6 Ordering Instructions ICX 15 kv DIGIT 4 Terminal Connectors DIGIT 6 Special Options DIGIT 11 Additional Options DIGIT 2 Insulator BIL 1 = 110 kv N = No terminal C = Clamshell E = Eyebolt N = None F = Wildlife guard Y = Combo box K = Kickout spring on fuse tube X 1 DIGIT 3 Fuse Support N = Porcelain J = Silicone Z = Polymer concrete E = Emission control DIGIT 5 Bracket N = No bracket A = NEMA A B = NEMA B L = Extended U = Pole Mounting DIGITS 7-10 Fuseholder AM11 = 100A, 10kAIC, Solid cap LM11 = 100A, 16kAIC, Link extender KA21 = 200A, 12kAIC, Link extender PA21 = 200A, 10kAIC, Link extender (rated 7.8/15 kv) CA31 = 300A, Solid blade ICX 27 kv DIGIT 2 Insulator BIL 2 = 125 kv BIL 4 = 150 kv BIL 600 mm creep ( only) 5 = 150 kv BIL 8 = 180 kv BIL 750 mm creep ( only) 9 = 200 kv BIL 1130 mm creep ( only) DIGIT 4 Terminal Connectors N = No terminal C = Clamshell E = Eyebolt DIGIT 6 Special Options N = None F = Wildlife guard Y = Combo box DIGIT 11 Additional Options K = Kickout spring on fuse tube X DIGIT 3 Fuse Support N = Porcelain J = Silicone Z = Polymer concrete (125 BIL only) E = Emission control DIGIT 5 Bracket N = No bracket A = NEMA A B = NEMA B L = Extended U = Pole Mounting DIGITS 7-10 Fuseholder AM12 = 100A, 8kAIC, Solid cap GM12 = 100A, 12kAIC, Link extender MM12 = 100A, 16kAIC, Link extender VA22 = 200A, 12kAIC, Link extender WA22 = 200A, 12kAIC, Link extender (rated 15/27 kv) DA32 = 300A, Solid blade - 6 -
7 ICX 38 kv, 150 or 180 kv BIL DIGIT 2 Insulator BIL 4 = 150 kv BIL 600mm creep ( only) 5 = 150 kv BIL 8 = 180 kv BIL 750mm creep ( only) DIGIT 4 Terminal Connectors N = No terminal C = Clamshell E = Eyebolt DIGIT 6 Special Options N = None F = Wildlife guard Y = Combo box DIGIT 11 Additional Options K = Kickout spring on fuse tube X DIGIT 3 Fuse Supports N = Porcelain J = Silicone E = Emission control DIGIT 5 Bracket N = No bracket A = NEMA A B = NEMA B L = Extended U = Pole Mounting DIGITS 7-10 Fuseholder TA12 = 100A, 10kAIC, Link extender DA32 = 300A, Solid blade ICX 38 kv, 170 kv BIL DIGIT 4 Terminal Connectors DIGIT 6 Special Options DIGIT 11 Additional Options DIGIT 2 Insulator BIL 7 = 170 kv N = No terminal C = Clamshell E = Eyebolt N = None F = Wildlife guard Y = Combo box K = Kickout spring on fuse tube X 7 DIGIT 3 Fuse Supports N = Porcelain DIGIT 5 Bracket N = No bracket A = NEMA A B = NEMA B L = Extended U = Pole Mounting DIGITS 7-10 Fuseholder RA15 = 100A, 10kAIC, Link extender FA34 = 300A, Solid blade RA14 = 100A, 12kAIC, Link extender (tube rated for 27 kv) SA24 = 200A, 10kAIC, Link extender (tube rated for 15/27 kv) - 7 -
8 Optional Cutout Parts Replacement Fuseholders Style Number Voltage (kv) BIL (kv) Current (A) Interrupting (kaic) Cap Type Corresponding Cutout* 7194C60G01MP Solid AM C60G02MP Link Extender LM C60G03 7.8/ Link Extender PA C60G Solid Disconnect Blade CA C60G05MP or Solid AM C60G06MP or Link Extender MM C60G07 15/ or Solid BA C60G or Solid Disconnect Blade DA C60G Solid Disconnect Blade DA C60G11MP Link Extender MM C60G12MP Solid Disconnect Blade EA C60G Link Extender KA C60G or Link Extender VA22 * Used with ICX cutouts having the following characters in digit positions 7-10 of the ABB cutout style number. Replacement Fuseholder Caps Style Number Voltage (kv) BIL (kv) Current (A) Interrupting (kaic) Cap Type 3A31186H Solid Cap 9861A62G Link Extender 9861A62G08 7.8/ Link Extender 3A31187H01 15/ or Solid Cap 3A31186H or Solid Cap 9861A62G or Link Extender 9861A62G Link Extender Brackets Style Number 367C723G05 403A101G03 367C802G04 791C890G16 Type NEMA A NEMA B Extended Pole Mounting 1VAG DB Rev. A December 2004 (replaces ) Copyright 2004 ABB. All rights reserved. ABB Inc. 406 Banner Ave. Greensboro, NC Tel:
Type ICX Outdoor open type cutout
Distribution cutouts Type IC Outdoor open type cutout Product features 7.8 kv, 15 kv, 15/27 kv, 27 kv, or 38 kv on 100 A 7.8 kv, 15 kv, and 15/27 kv only on 200 A 110, 125, 150, 170, or 180 kv BIL 180
More informationType L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description
Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution
More informationMedium Voltage Outdoor Apparatus Portfolio 2009
PPMV, April/May 2009 Medium Voltage Outdoor Apparatus Portfolio 2009 May 5, 2009 Slide 1 Summary Reclosers Outdoor dead tank vacuum circuit breakers Outdoor live tank circuit breakers Pole mounted circuit
More informationUltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout
Fusing Equipment Catalog Data CA132035EN Supersedes November 2015 COOPER POWER SERIES UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Description Eaton has set a standard
More informationGROUP D. Switch & Protective device.
GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated
More informationPRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT
PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze
More informationWestinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401
February 26, 1976 Supersedes PL 38-640 dated October 15,1974 Pages 1-8 Prices effective April 29, 1974 Subject to change without notice Selling Policy 38-000 Mailed to E, D, C/1991, 2430/ PL Standard Bill
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015
10AA Type C-POLYMER Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all
More informationS&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)
S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013
10AA Type C-Polymer Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all
More informationOutdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter
Outdoor Distribution (5 kv through 25 kv) S&C Fault Tamer Fuse Limiter Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015
10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,
More informationAutoLink Frequently Asked Questions
Rev. 3 October 2013 Page 1 of 8 AutoLink Frequently Asked Questions October 2013 1 Rev. 3 October 2013 Page 2 of 8 Table of Contents 1 Background... 4 1.1 What is the AutoLink Single Phase Electronic Sectionalizer?...
More informationPRODUCT CATALOGUE. Overhead System
PRODUCT CATALOGUE Overhead System Information Tel : 03-4777547 Fax : 03-4777570 E-mail : overseas@jaker.com.tw Web : www.jaker.com.tw Add : No.787, Xinwen Rd. Xinwu Dist., Taoyuan City 327, Taiwan Contents
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014
10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,
More informationDO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.
DO-III DO-III Fuse Holder TPL 44-835, May 2000, Page 1 of 4 General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder ABB Inc. General Description The ABB DO-III fuse holder is a draw
More informationQ pole Pole Mounted Capacitor System
Q pole Pole Mounted Capacitor System Introduction The ABB Qpole pole mount capacitor system is an economical solution for shunt reactive compensation on overhead distribution networks. The Qpole is suitable
More informationS&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv
TripSaver II Cutout-Mounted Recloser For enhanced lateral circuit protection at 15 kv and 25 kv Introducing s new TripSaver II Cutout-Mounted Recloser: A better solution for overhead lateral circuit protection
More informationDescriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications
Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter
More informationThree-Phase Pole Mounted Recloser
Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE
More information100 / 110 DRYWELL FUSE SPECIFICATION
100 / 110 DRYWELL FUSE SPECIFICATION 15KV & 25KV SUBMERSIBLE VACUUM LOAD INTERRUPTERS AND DRYWELL FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED SUBMERSIBLE SWITCHGEAR WITH LOAD INTERRUPTING SWITCHES
More informationFigure 1. HX cutout fuseholders.
Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus K-SEC 010 GENERAL Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted
More informationFigure 1. HX cutout fuseholders. Positive Interruption
Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus 327-10 general Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted to
More informationشركة كهرباء محافظة القدس المساهمة المحدودة
Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories
More information10DD 10DD-1. Section CAUTION:
POLYMER Electronic Resettable Sectionalizer Protected by U.S. Patents No. 6,593,842; 5,854,582; 5,612,661; 4,935,715; 4,795,996; and other patents pending Section 10DD-1 10DD Warranty - Material Hubbell
More informationProduct Group Brochure. PS Range Capacitor Vacuum Switches
Product Group Brochure PS Range Capacitor Vacuum Switches Introduction ABB introduces the latest range of PS capacitor vacuum switches. Building on the proven PS switch design, new single phase and three
More information34-SDMS-01 SPECIFICATIONS FOR
SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES
More informationS&C Manual PME Pad-Mounted Gear
S&C Manual PME Pad-Mounted Gear Outdoor Distribution,. kv and 5 kv S&C Manual PME Pad-Mounted Gear... Featuring Elbow-Connected Encased Components. S&C Manual PME Pad-Mounted Gear brings in-air insulation,
More informationCutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526
Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526 Section 10A 10A-1 Warranty - Material Hubbell Power Systems, Inc. warrants all products sold
More informationElectronic Resettable Sectionalizer
POWER SYSTEMS, INC. Protected by U.S. Patents No. 5,612,661; 4,935,715; DES. 278,331 and other patents pending Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable
More informationVersaRupter 5-38 kv Load Interrupter Switch. Technical Guide
VersaRupter 5-38 kv Load Interrupter Switch Technical Guide NOTICE Components in this catalog are intended for use by switchgear assemblers engaged in original equipment manufacturing. All sales are subject
More informationSERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES
SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED SWITCHGEAR WITH VACUUM LOAD
More informationWLI Medium Voltage Switchgear Renewal Parts
Page 1 Supersedes Renewal Parts Data, pages 1-2, dated June 1992, WLI Medium Voltage Switchgear Renewal Parts Page 2 Standard Manually Operated Fused WLI Switch ➇ ➁ ➀ ➂➃ WLI Switch Mechanism ➉ ➈ m Replacement
More informationMolded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV
The recloser you want, all in one package. Single- and Three-Phase, 15 38kV The need for automated reclosers has never been greater, but many of today s reclosers come with penalties. They weigh too much,
More informationType M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary
14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching
More informationCOOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing
Fusing Equipment MN132028EN Effective November 2016 Supersedes June 2012 (S240-66-1) COOPER POWER SERIES ELF Current-Limiting Dropout Fuse Installation Instructions Pull ring Housing Lifting eye Identification
More informationSurge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)
Surge s UltraSIL Polymer-Housed VariSTAR Surge s: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Electrical Apparatus 235-35 General Cooper Power Systems has set the standard
More informationCOOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN
Surge Arresters MN235004EN Effective December 2015 Supersedes S235-26-1 August 2012 COOPER POWER SERIES Surge arrester interchangeable fuse cutout combination installation instructions DISCLAIMER OF WARRANTIES
More informationS&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)
S&C Loadbuster Disconnect Switches Outdoor Distribution ( kv through 34.5 kv) S&C s Loadbuster Disconnect Switches, when used with S&C s Loadbuster tool, provide the ultimate in distribution live-switching
More informationS&C Loadbuster Disconnects
S&C Loadbuster Disconnects Outdoor Distribution ( kv through 34.5 kv) With these outstanding features... Up to -ampere continuous ratings, 40,000-ampere RMS asymmetrical momentary ratings Designed for
More informationDescriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv
Descriptive Bulletin R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Introduction The R-MAG TM is truly the next generation in medium voltage vacuum circuit breaker
More informationSUBSTATION VACUUM CIRCUIT BREAKER (38KV)
SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)
SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products
More informationTYPE BLT DISCONNECT SWITCHES
TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH
More informationSUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)
SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationDescriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv
Descriptive Bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Introduction The R-MAG is truly the next generation in medium voltage vacuum circuit breaker technology.
More informationSpecifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)
Outdoor Distribution (4.16 through 25 ) Specifications Conditions of Sale STANDAD: Seller s standard conditions of sale set forth in Price Sheet 153 apply, except as modified under WAANTY QUALIFICATIONS
More information26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.
.3 Power Breakers, Contactors and Fuses Fuses General Contents Description Fuses General Product Overview Power Fuse Eaton s roots in the medium voltage power fuse business began over 75 years ago under
More informationNOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice.
CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is defined in
More information3EK7 Medium Voltage Silicone Insulated Surge Arresters
3EK7 Medium Voltage Silicone Insulated Surge Arresters Power Transmission and Distribution Setting new Standards The 3EK7 s mechanical features: Glass-collared MOV, Silicone rubber housing, FRP rods and
More informationM-Force three-phase switch
Supersedes K-SEC 926 December 2012 M-Force three-phase switch Description The M-Force switch from Eaton's Cooper Power Systems is a distribution-class, gangoperated, factory unitized three-phase overhead
More informationProduct Selection Guide
Oil-Submersible Backup Fuses Full-Range CL Fuses External Backup Fuses Molded Fuse Products Product Selection Guide Introduction Electric distribution systems demand high levels of reliability, and flexibility
More informationDisconnect & ByPass Switches
Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class
More informationSurge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets
Surge Arresters Surge Arrester/Type L use ombination Electrical Apparatus 235-26 escription ooper Power Systems surge arrester/type L interchangeable fuse cutout combinations are available in a wide variety
More informationME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv
ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv ABB ME series fused sectionalizing enclosures ABB's dead-front Padmount ME series
More informationS&C Type XS Fuse Cutouts
S&C Type XS Fuse Cutouts Outdoor Distribution 4.16 kv through 25 kv Application An Unexcelled Cutout S&C Type XS Fuse Cutouts, when fused with S&C Positrol Fuse Links provide full-fault-spectrum protection
More information1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches
1VAL2401-SG Rev D Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches Reclosers GridShield recloser 12A00736H05 Actuator assist capacitor Single-phase upgrade 15 KV, 800 A, 12.5
More informationTechnical Specification for Pole Mounted Capacitor Rack
Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to
More informationJUMPERS & SWITCHING TOOLS
INSULATED JUMPER SETS 368 INSULATED JUMPER SETS FOR 15 KV, 25KV AND 35 KV Used for bypassing work areas when upgrading lines and when making temporary or emergency repairs Continuous-current ratings for
More informationTYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV
Cutler Hammer SECTION PB-1A-110 PAGE 1 Replaces April, 1996 TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV The PSI/II Padmount is the second generation of switchgear in the PSI switchgear family. The PSI/II
More informationCLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12
Bulletin DB-104E12 Type RL-C Side Break Switch 7.2-69 kv 600-2000 A. CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Type RL-C
More informationwww. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open
Substation Transformers Primary or Secondary Open GENERAL Cooper Power Systems Primary or Secondary Open Substation Transformers are designed to meet exact customer specifications. Flexibility in design,
More informationProduct Specifications for Phase Over Phase GOABS(r)
1. General a) This specification covers the design, manufacture, and shipment of phase-over-phase, 1-way, 2-way, 3-way, and 4-way, gang-operated disconnecting switches, both air-break and load-break, for
More informationAdvance 27 ANSI 27 kv switchgear
Advance 27 ANSI 27 kv switchgear Table of contents Advance 27...3 AMVAC breaker...4 Instrument transformers...5 Current transformers...5 27 kv voltage transformers...6 Distribution protection and control...7
More informationT YPE MZ DISTRIBUTION S TANDARD CUTOUT
T YPE MZ DISTRIBUTION S TANDARD CUTOUT Page 1 of 7 The Fuse Cutout type MZ was developed to operate in overhead distribution systems rated at 15, 27 and 38 kv grounded systems with 100 or 200 A nominal
More informationCobra-S. Catalog Cobra-S
Cobra-S Solid Dielectric, Three Phase Reclosers Providing electronic three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5/16kA symmetrical interrupting Control
More informationSpecifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)
S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard
More informationSection 1 Introduction to the Presentation
2007 Thomas & Betts Section 1 Introduction to the Presentation Introduction of T&B Hi-Tech Fuses and our products Expulsion fuses vs. Current-Limiting fuses Hi-Tech s fuse construction & design features
More informationHUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary
Catalog 14B January 2015 HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch.
More informationProduct Specifications for Aluminum Vertical Break Switches
1. General a) This specification covers the design, manufacture, and shipment of aluminum vertical break switches, both air-break and load-break configurations, for substation and transmission switching
More informationKuhlman Electric Corporation Volt Instrument Transformers
Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High
More informationPSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.
Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.
More informationDry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break
Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926 Technical Guide Load-break, General Description The Drywell Current Limiting Fuse Cannister is a removable fuse assembly for use in single and three
More informationS&C Type XS Fuse Cutouts
S&C Type XS Fuse Cutouts Outdoor Distribution (4.16 kv through 25 kv) S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection Descriptive Bulletin 351-30 August 25, 2003 Supersedes
More informationEpoxy Technology Embedded Poles
Embedded Poles ABB Power Technologies / 1-6994 E 14-03-03 - Epoxy processing Experience in manufacturing of epoxy resin for indoor and outdoor applications Processing of more than 1,000 tons epoxy resin
More informationCOOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN
Fusing Equipment MN132011EN Effective January 2016 Supersedes KS1.1-01-1 May 2003 HX-CB loadbreak fuse cutout installation instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY
More informationEE 741 Over-voltage and Overcurrent. Spring 2014
EE 741 Over-voltage and Overcurrent Protection Spring 2014 Causes of Over-voltages Lightning Capacitor switching Faults (where interruption occurs prior to zero current crossing) Accidental contact with
More informationKuhlman Electric Corporation Volt Instrument Transformers
Kuhlman Electric Corporation 34500 Volt Instrument Transformers 34500 Volt Table of Contents Description Model Page Wound, Dry-Type VT Y (High Accuracy available) PTT-200-9710(H) 3-4 Wound, Oil-Filled
More informationType HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv
Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv HS PEXLIM-P Metal Oxide Surge Arrester HS PEXLIM-P Surge Arresters are used for the protection of switchgear, transformers and other
More informationRBA Catalog Numbers and Information
50 RBA s and Information Type RBA Expulsion Fuses for Use Indoors or in an Enclosure Ampere Rating Standard Speed (Fuse Refills) Curve Reference 36-635 Time-Lag (Fuse Refills) Curve Reference 36-635 Approx.
More informationSERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES
SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT SUBMERSIBLE AND VAULT MOUNTED
More informationSurge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features
Surge s Electrical Apparatus 235-99 General Cooper Power Systems set the standard for design, manufacturing and delivery of polymeric distribution arresters with the UltraSIL polymerhoused arrester family.
More informationSolar Combiner Solutions
Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from
More informationM-Force three-phase switch
Switches and Disconnects CA008004EN Supersedes May 2015 COOPER POWER SERIES M-Force three-phase switch Description Eaton's Cooper Power series M-Force switch is a distribution-class, gang-operated, factory
More informationProduct Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher
TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 2 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...
More informationDesign Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak
Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers
More informationOVR Three Phase Recloser 15 kv - 38 kv. Descriptive Bulletin
OVR Three Phase Recloser 15 kv - 38 kv Descriptive Bulletin Always a Generation Ahead ABB continually strives to bring customers the latest technological advances and superior performance. This is especially
More informationTRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS
TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS 33220900 DECEMBER 2011 Caution: The equipment covered by these installation instructions should be installed and serviced only by properly trained
More informationUnderground Distribution Switchgear
Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,
More informationFusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element
Fusing Equipment Kearney Fuse Links Electrical Apparatus 327-40 general Cooper Power Systems Kearney fuse links can be applied to a variety of applications requiring overcurrent protection of distribution
More informationPadmount Solid Dielectric Switchgear Catalog
Padmount Solid Dielectric Switchgear Catalog p G&W headquarters in Bolingbrook, IL USA Company Profile Since 1905, G&W Electric has helped energize the world with innovative power system solutions. With
More informationType IMC Indoor current transformer
Instrument transformers Type IMC Indoor current transformer Product features 600 volt indoor 10 kv BIL 25 through 400 Hertz amperes: 50-1000 2.5" (64 mm) round window Designed for variable applications
More informationSURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION
Fusing Equipment Tandem ELF Current-Limiting Dropout Fuse Electrical pparatus 240-67 GENERL The Cooper Power Systems Tandem ELF current-limiting fuse is designed for transformer protection. The Tandem
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationUnitized Quick Install Switches for Transmission Applications
Bulletin DB-600A12 Unitized Quick Install Switches for Transmission Applications Vertical Break Switches Center Break V Switches CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177
More informationK-Limiter high ampere Companion II fuse
Fusing Equipment Catalog Data CA132059EN Supersedes February 2016 COOPER POWER SERIES K-Limiter high ampere Companion II fuse General Eaton designs its Cooper Power series K-Limiter fuse to be conveniently
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin SafeGear Motor Control Center Arc resistant Metal-Clad construction Descriptive Bulletin Table of Contents
More informationSurge Arresters. Supply Program. Answers for energy.
Surge Arresters Supply Program www.siemens.com/energy/arrester Answers for energy. Always the Best Solution We offer an extensive range of surge arresters suitable for every application economical and
More informationPOWER SYSTEMS, INC. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS
CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBITIONS Warranty - Material Chance warrants all products sold by it to be merchantable (as such term is defined in the Uniform Coercial
More informationType POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv
Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv POLIM-S Metal Oxide Gapless Surge Arresters POLIM-S Surge Arresters are used for the protection of switchgear, transformers and other
More information