PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT
|
|
- Virgil Newton
- 6 years ago
- Views:
Transcription
1 PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze with silver plated On load hook for load buster Insulator One-piece bird proof porcelain Fuse tube with vulcanize bone fiber liner inside fiber glass reinforced epoxy resin which color painting UV resistance Trunnion high strength cast bronze silver plated movable contact Hinge stainless steel for corrosion resistance Feature Maximum voltage design 38kV Rated continuous current 100A Drop down open fuse cutout Non expendable cap Single vent expulsion fuse holder Single core bird proof of porcelain for fuse cutout body Off load operation but have hook for on load by load buster Apply for protection over current and fault of distribution line and distribution equipment such as power transformer, current transformer or capacitor bank etc. Spring latch (No visible) to prevent open fuse holder from vibration Type test report PRECISE INTERNATIONAL CORPORATION LTD. Sale Office: 1842 Krungthep-Nonthaburi Rd., Bangsue, Bangkok, Thailand Telephone: (662) Telefax: (662) Website: info@precise.co.th April 2007: Rev.1
2 PRECISE PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Type PGC Cutout dimensions with NEMA Bracket Type B Dimensions Data A B C D E In millimeters unit Performance Characteristics Applied standard ANSI C37.42 Catalog number Nominal system voltage kv-rms 33 Maximum voltage design kv-rms 38 Dry withstand voltage kv-rms 70 Wet withstand voltage kv-rms 60 BIL 1.2x50µs kv-peak 150 Continuous current A-RMS 100 Interrupting current asymmetrical/symmetrical A-RMS 8000 / 5000 Frequency Hz 50 Creepage distance to Ground Min. mm 650 Ambient air temperature Up to 40 o C Attitude Up to 1000 m Vertical insulator angle from center line of cutout body degree Approximate weight with NEMA Bracket kg. 13 Fuse holder expulsion Non-Expendable cap Factsheet No.: PGP-PGP102-FC-0002 Factsheet: State 3 Issued On : 01/04/2007 Authorized Dealer: Revision No. 0 Date : 01/04/2007
3 PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 27kV 100A 8kA asym. Type PGP Parallel groove terminal bronze with tin plated NEMA Bracket type B Insulator One-piece bird proof porcelain Upper contact copper with silver plated Cap - Cast bronze with silver plated On load hook for load buster Fuse tube with vulcanize bone fiber liner inside fiber glass reinforced epoxy resin which color painting UV resistance Hinge Stainless steel for corrosion resistance Feature Maximum voltage design 27kV Rated continuous current 100A Drop down open fuse cutout Non expendable cap Single vent expulsion fuse holder Single core bird proof of porcelain for fuse cutout body Interchangeability to S&C type XS,AB Chance type C and ABB type ICX Off load operation but have hook for on load by load buster Apply for protection over current and fault of distribution line and distribution equipment such as power transformer, current transformer or capacitor bank etc. Trunnion high strength cast bronze silver plated movable contact Spring latch (No visible) to prevent open fuse holder from vibration Type test report PRECISE INTERNATIONAL CORPORATION LTD. Sale Office: 1842 Krungthep-Nonthaburi Rd., Bangsue, Bangkok, Thailand Telephone: (662) Telefax: (662) Website: info@precise.co.th April 2007: Rev.1
4 PRECISE PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 27kV 100A 8kA asym. Type PGP Type PGP Cutout dimensions with NEMA Bracket Type B Dimensions Data A B C D E In millimeters unit Performance Characteristics Applied standard ANSI C37.42 Catalog number Nominal system voltage kv-rms 22 Maximum voltage design kv-rms 27 Dry withstand voltage kv-rms 42 Wet withstand voltage kv-rms 36 BIL 1.2x50µs kv-peak 125 Continuous current A-RMS 100 Interrupting current asymmetrical/symmetrical A-RMS 8000 / 5600 Frequency Hz 50 Creepage distance to ground Min. mm 320 Ambient air temperature Up to 40 O C Altitude Up to 1000m Vertical insulator angle from center line of cutout body degree Approximate weight with NEMA Bracket kg. 9 Fuse holder interchangeability * Fuse holder expulsion Non-Expendable cap * Interchange with S&C type XS, AB Chance type C and ABB type ICX Factsheet No.: PGP-PGP102-FC-0001 Factsheet: State 3 Issued On : 01/04/2007 Authorized Dealer: Revision No. 0 Date : 01/04/2007
5 PRECISE HIGH VOLTAGE FUSE LINKS FUSE LINKS TYPE K Flexible wire : easy to engage with bolt on fuse cutout s trunnion Removable button head can be removed for using with arc shortening rod ARC-extinguishing tube Strain wire prevents fuse element Fuse element Rated current was to be broken from tension force by emboss on flipper latch High Voltage Fuse Links Feature Design and manufacture accordance to ANSI C37.42 Removable button head style for using with arc shortening Use to drop out fuse cutout maximum design voltage 27kV and 38kV High Voltage Fuse Links Drawing Performance Characteristics Ampere PRECISE INTERNATIONAL CORPORATION LTD. Sale Office: 1842 Krungthep-Nonthaburi Rd., Bangsue, Bangkok, Thailand Telephone: (662) Telefax: (662) Website: info@precise.co.th Catalog number C (mm) Min. Ø A (mm) 27kV 38kV 27kV 38kV ±0.5 mm Ø B (mm) ±0.5 mm Ø D (mm) ±0.5 mm Ø F (mm) ±1.5 mm 1 K00127 K K00227 K K00327 K K00627 K K00827 K K01027 K K01227 K K01527 K K02027 K K02527 K K03027 K K04027 K K05027 K K06527 K NO K08027 K NO K10027 K NO Note: 1) Button head thread size1/4 ¼ pitch G28 length 7 mm +/- 1 mm 2) For rated current 1, 2 and 3A have only one fuse element instead of strain wire position 3) Washer will be supply only with current rated 1 to 50 Amperes April 2007: Rev.1
6 PRECISE PRECISE HIGH VOLTAGE FUSE LINKS PRECISE fuse links Time-Current Characteristics Cur ve Factsheet No.: PGP-PGP102-FL-0003 Factsheet: State 3 Issued On : 01/04/2007 Authorized Dealer: Revision No. 0 Date : 01/04/2007
7 PRECISE LOW TENSION FUSE SWITCH LOW TENSION FUSE SWITCH 400A 500V Metal base is hot dip galvanize malleable iron One piece porcelian insulator Terminal pad bronze with tin plated and 9/16 of hole for conductor Phenolic paper laminate sheet for fuse carrier Contact is copper with silver plate Clamping assemble is stainless steel Pull ring and Lift ring is hot dip galvanize and 26mm diameter for hook sticks Type test report Feature Design and manufacture accordance to IEC Suits HRC fuse bolted connections type size B1 to B4 and blade contacts type size 0 to 2 accordance to IEC Single pole Single throw switch Rated maximum voltage 500V and 400A maximum current Suits NEMA PAD 2 Holes terminal Suits standard hook-sticks On-load switching capability PRECISE INTERNATIONAL CORPORATION LTD. Sale Office: 1842 Krungthep-Nonthaburi Rd., Bangsue, Bangkok, Thailand Telephone: (662) Telefax: (662) Website: info@precise.co.th April 2007: Rev.1
8 PRECISE PRECISE LOW TENSION FUSE SWITCH LOW TENSION FUSE SWITCH Low tension fuse switch dimensions with HRC fuse Dimensions Data A B C D In millimeters unit Performance Characteristics Applied standard IEC Rated operation voltage V-RMS 500 Rated insulation voltage V-RMS 1000 Rated operation current with fuse link A-RMS 400 Rated frequency Hz 50 Rated condition short-circuit current ka-rms 50 Rated impulse withstand voltage kv-peak 12 Rated make-break current at 0.65 PF, 5 operation cycle A-RMS Creepage distance Min. mm 32 Utilization category 600 AC-21B Infrequent operation with current 220* Infrequent operation without current 1400* Degree of protection IP00 Approximate overall weight kg. 2.8 Model *Number of operation cycle at 60 operations cycle hour OFS-4A5 Factsheet No.: PGP-PGP102-FS-0004 Factsheet: State 3 Issued On : 01/04/2007 Authorized Dealer: Revision No. 0 Date : 01/04/2007
Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description
Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution
More information34-SDMS-01 SPECIFICATIONS FOR
SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES
More informationT YPE MZ DISTRIBUTION S TANDARD CUTOUT
T YPE MZ DISTRIBUTION S TANDARD CUTOUT Page 1 of 7 The Fuse Cutout type MZ was developed to operate in overhead distribution systems rated at 15, 27 and 38 kv grounded systems with 100 or 200 A nominal
More informationUltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout
Fusing Equipment Catalog Data CA132035EN Supersedes November 2015 COOPER POWER SERIES UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Description Eaton has set a standard
More informationشركة كهرباء محافظة القدس المساهمة المحدودة
Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories
More informationFigure 1. HX cutout fuseholders. Positive Interruption
Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus 327-10 general Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted to
More informationFigure 1. HX cutout fuseholders.
Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus K-SEC 010 GENERAL Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted
More informationT HREE-SHOT TYPE MZR F USE CUTOUT
T HREE-SHOT TYPE MZR F USE CUTOUT Page 1 of 7 D ESCRIPTION It is known that about 90% of the defects that occur in an air distribution system, are of a transient origin, i.e., are transient faults which
More informationTYPE BLT DISCONNECT SWITCHES
TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH
More informationDescriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications
Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter
More informationS&C Recloser Bypass Disconnects
S&C Recloser Bypass Disconnects Outdoor Distribution (14.4 kv through 34.5 kv) Application S&C Recloser Bypass Disconnects are station-type devices used to bypass and isolate automatic circuit reclosers
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015
10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014
10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,
More informationS&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)
S&C Loadbuster Disconnect Switches Outdoor Distribution ( kv through 34.5 kv) S&C s Loadbuster Disconnect Switches, when used with S&C s Loadbuster tool, provide the ultimate in distribution live-switching
More informationGROUP D. Switch & Protective device.
GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated
More informationType M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary
14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching
More informationMGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:-
MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:- 01) SCOPE: This specification covers outdoor, open, drop out expulsion type fuse cut outs suitable for installation in 50Hz, 11KV distribution
More informationSpecifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)
S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard
More informationType ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB
Type ICX Interchangeable Cutout 15-38 kv Outdoor Distribution Cutout Product Bulletin 1VAG271201-DB Product Features 15, 27, or 38 kv 110, 125, 150, 180, or 200 kv BIL 100 A, 200 A Fused 300 A Disconnect
More informationVersaRupter 5-38 kv Load Interrupter Switch. Technical Guide
VersaRupter 5-38 kv Load Interrupter Switch Technical Guide NOTICE Components in this catalog are intended for use by switchgear assemblers engaged in original equipment manufacturing. All sales are subject
More informationType ICX Outdoor open type cutout
Distribution cutouts Type IC Outdoor open type cutout Product features 7.8 kv, 15 kv, 15/27 kv, 27 kv, or 38 kv on 100 A 7.8 kv, 15 kv, and 15/27 kv only on 200 A 110, 125, 150, 170, or 180 kv BIL 180
More informationDisconnect & ByPass Switches
Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class
More informationS&C Loadbuster Disconnects
S&C Loadbuster Disconnects Outdoor Distribution ( kv through 34.5 kv) With these outstanding features... Up to -ampere continuous ratings, 40,000-ampere RMS asymmetrical momentary ratings Designed for
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013
10AA Type C-Polymer Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all
More informationCutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015
10AA Type C-POLYMER Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all
More informationWestinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401
February 26, 1976 Supersedes PL 38-640 dated October 15,1974 Pages 1-8 Prices effective April 29, 1974 Subject to change without notice Selling Policy 38-000 Mailed to E, D, C/1991, 2430/ PL Standard Bill
More informationDO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.
DO-III DO-III Fuse Holder TPL 44-835, May 2000, Page 1 of 4 General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder ABB Inc. General Description The ABB DO-III fuse holder is a draw
More informationTECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:
TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators: (1) SCOPE: This specification covers outdoor, open, drop out expulsion type fuse cut outs suitable for installation in
More informationWESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2
Sl. No. WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO GUARANTEED TECHNICAL PARTICULARS 1 of 2 REQUIREMENTS 11 Kv, 200 Amps, A.B Switches. Particulars 1 Maker's name and Country of origin. 2 Type
More informationCENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B
CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B TCV2 Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com
More information045 : 2000 CEB STANDARD
045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.
More informationPRODUCT CATALOGUE. Overhead System
PRODUCT CATALOGUE Overhead System Information Tel : 03-4777547 Fax : 03-4777570 E-mail : overseas@jaker.com.tw Web : www.jaker.com.tw Add : No.787, Xinwen Rd. Xinwu Dist., Taoyuan City 327, Taiwan Contents
More informationS&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv
TripSaver II Cutout-Mounted Recloser For enhanced lateral circuit protection at 15 kv and 25 kv Introducing s new TripSaver II Cutout-Mounted Recloser: A better solution for overhead lateral circuit protection
More informationOVERHEAD DISTRIBUTION SWITCHES
OVERHEAD DISTRIBUTION SWITCHES 0800 442 182 www.transnet.co.nz CONTENTS LineBOSS 15kV - 35kV Sidebreak GOAB Switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 LineBOSS Selection
More informationNOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice.
CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is defined in
More informationSpecifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)
Outdoor Distribution (4.16 through 25 ) Specifications Conditions of Sale STANDAD: Seller s standard conditions of sale set forth in Price Sheet 153 apply, except as modified under WAANTY QUALIFICATIONS
More informationCatalog 14A January 2013
Catalog 14A January 2013 Page 1 January 2013 Type AR (Automation-Ready) Switch 14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt Description The Hubbell unitized Type AR switch is a distribution-level,
More information: DGVCL/11KV D.O.FUSE/SPECIFICATION : : 11KV DROP OUT FUSE CUTOUTS :
: DGVCL/11KV D.O.FUSE/SPECIFICATION : : 11KV DROP OUT FUSE CUTOUTS : FOREWORD : Even though 11KV Drop Cut Fuse Cut Outs are widely used for protection / isolation of distribution transformers, their quality
More informationProduct Specifications for Aluminum Vertical Break Switches
1. General a) This specification covers the design, manufacture, and shipment of aluminum vertical break switches, both air-break and load-break configurations, for substation and transmission switching
More informationRBA Catalog Numbers and Information
50 RBA s and Information Type RBA Expulsion Fuses for Use Indoors or in an Enclosure Ampere Rating Standard Speed (Fuse Refills) Curve Reference 36-635 Time-Lag (Fuse Refills) Curve Reference 36-635 Approx.
More informationCutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526
Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526 Section 10A 10A-1 Warranty - Material Hubbell Power Systems, Inc. warrants all products sold
More informationTYPE V CENTER BREAK SWITCH
TYPE V CENTER BREAK SWITCH 3-PHASE, GROUP-OPERATED (SUBSTATION AND TRANSMISSION APPLICATIONS) *Available in Copper Horizontal upright, vertical or underhung mounting 15KV through 230KV 600A through 4000A
More informationMedium Voltage Capacitors
Type MSCE and MSCD Features that matter: Single and Three-Phase Capacitors Up to 22 kv (50 / 60 Hz) Up to 1000 kvar For indoor and outdoor installation 1 Type MSCE and MSCD Application Product Scope The
More informationNH fuse-links am VAC with striker, size 0, 1, 2, 3, 4
NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,
More informationHUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary
Catalog 14B January 2015 HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch.
More informationTechnical Specification for Pole Mounted Capacitor Rack
Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to
More informationwww. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003
Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More information023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA
023 : 2006 CEB STANDARD 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA Specification for 12kV & 36kV LOAD BREAK SWITCHES CEB Standard 023 : 2006 CEYLON ELECTRICITY BOARD No. 50, Sir
More informationNH fuse-links am 690VAC top indicator/live tags size 4, 4a
NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %
More informationTechnical Specification For Outdoor Substation Harmonic Filter Banks
Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field
More informationResin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK
1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More informationNH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a
NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium
More informationElectronic Resettable Sectionalizer
POWER SYSTEMS, INC. Protected by U.S. Patents No. 5,612,661; 4,935,715; DES. 278,331 and other patents pending Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable
More informationProduct Specifications for Phase Over Phase GOABS(r)
1. General a) This specification covers the design, manufacture, and shipment of phase-over-phase, 1-way, 2-way, 3-way, and 4-way, gang-operated disconnecting switches, both air-break and load-break, for
More informationSpecifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.
S&C Power Fuses s SM and SMLa Indoor Distribution (4.16 through 34. ) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set
More informationResin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide
1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More informationLoad Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount
Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA 5321-100 Technical Guide Nut Mount Weld Mount General Description The ABB Type LBOR-II switch is a manually operated, two position, load make
More informationTABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3
TITLE SPECIFICATION FOR MEDIUM VOLTAGE DATE: FEBRUARY 2015 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD... 2 INTRODUCTION... 3 1 SCOPE... 3 2 NORMATIVE S... 3 3 DEFINITIONS AND ABBIATIONS... 3 4 REQUIREMENTS...
More information43-SDMS-04 REV. 00 SPECIFICATIONS FOR
43-SDMS-04 REV. 00 SPECIFICATIONS FOR SHUNT CAPACITOR BANK 13.8 kv THROUGH 69 kv FOR PRIMARY DISTRIBUTION SUBSTATIONS This specification is property of SEC and subject to change or modification without
More informationJUMPERS & SWITCHING TOOLS
INSULATED JUMPER SETS 368 INSULATED JUMPER SETS FOR 15 KV, 25KV AND 35 KV Used for bypassing work areas when upgrading lines and when making temporary or emergency repairs Continuous-current ratings for
More informationOutdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter
Outdoor Distribution (5 kv through 25 kv) S&C Fault Tamer Fuse Limiter Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles
More informationK-Limiter high ampere Companion II fuse
Fusing Equipment Catalog Data CA132059EN Supersedes February 2016 COOPER POWER SERIES K-Limiter high ampere Companion II fuse General Eaton designs its Cooper Power series K-Limiter fuse to be conveniently
More informationAir-insulated switchgear UniGear type ZS1
Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5
More informationS&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)
S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles
More informationAutoLink Frequently Asked Questions
Rev. 3 October 2013 Page 1 of 8 AutoLink Frequently Asked Questions October 2013 1 Rev. 3 October 2013 Page 2 of 8 Table of Contents 1 Background... 4 1.1 What is the AutoLink Single Phase Electronic Sectionalizer?...
More informationRange : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions.
164 Fuse Holder consisting of carrier and base for mounting fuse links have been in use for long. Keeping operators safety and ease / reliability of removal in mind, a complete range of unique CAM operated
More informationJumpers & Load Pickup Tools
Jumpers & Load Pickup Tools Catalog 2300 May 2016 Jumpers & Load Pickup Tools 2300 May 2016 Page 2301 All Chance Insulated Jumpers meet ASTM F 2321 Standard Specification. G4758 15kV 5 5 / 8 " G4765 25kV
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical
More informationDIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.
DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them
More information1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide
1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information3.0OVERHEAD TRANSMISSION SWITCHES
HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 3 Overhead Transmission Switches CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,
More informationNH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a
LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection
More information1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide
1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover
More information2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)
.7 Expulsion Fuses RBA Fuses Product Description BA Fuses Westinghouse Electric Company introduced the BA range of DE-ION boric acid refillable fuses in the 1930s, and BA refill units have been in continuous
More informationDAQO Technical Differences of Isolated Phase Bus Standards. Study of Design Standard Variances, Insulator Design and Shipping Section Design
DAQO Technical Differences of Isolated Phase Bus Standards Study of Design Standard Variances, Insulator Design and Shipping Section Design Global Reference Medium Voltage Electrical Equipment Standards
More informationSPECIFICATION BULLETIN
SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS on page 3. SPECIAL TO THIS PRODUCT:
More informationNH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3
NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS
More informationBoric Acid Fuse Links
Boric Acid Fuse Links BBU Fuse Link Mount Construction Bird proof design insulator provides insulation characteristics higher than ANSI distribution cut-out standards and equal in most cases to ANSI switch
More informationTransformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC
Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC 60137-2008 High current bushings for transformer Features Bushing Type CFPT version Porcelain Insulator Trench RIG technology for
More informationQ pole Pole Mounted Capacitor System
Q pole Pole Mounted Capacitor System Introduction The ABB Qpole pole mount capacitor system is an economical solution for shunt reactive compensation on overhead distribution networks. The Qpole is suitable
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationSpecifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)
Outdoor Distribution (4.4 kv through 46 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 50 apply, except as modified under WARRANTY QUALIFICATIONS
More informationSURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION
Fusing Equipment Tandem ELF Current-Limiting Dropout Fuse Electrical pparatus 240-67 GENERL The Cooper Power Systems Tandem ELF current-limiting fuse is designed for transformer protection. The Tandem
More informationKuhlman Electric Corporation Volt Instrument Transformers
Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High
More information5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application
The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1
More informationNH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3
IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade
More informationS&C Type XS Fuse Cutouts
S&C Type XS Fuse Cutouts Outdoor Distribution 4.16 kv through 25 kv Application An Unexcelled Cutout S&C Type XS Fuse Cutouts, when fused with S&C Positrol Fuse Links provide full-fault-spectrum protection
More informationR-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A
R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationTYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV
Cutler Hammer SECTION PB-1A-110 PAGE 1 Replaces April, 1996 TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV The PSI/II Padmount is the second generation of switchgear in the PSI switchgear family. The PSI/II
More information2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)
.7 Expulsion Fuses RBA Fuses Product Description BA Fuses Westinghouse Electric Company introduced the BA range of DE-ION boric acid refillable fuses in the 1930s, and BA refill units have been in continuous
More informationLG HRC Power Fuses ISO 9001 ISO 14001
LG HRC Power Fuses ISO 900 ISO Current without Power Fuse (ka ms) Ipeak Let through Below 0.5 Cycle voltage(kv) Initiation of 3. 7. 5.5 3 arcing(degree) Ipeak(kA) Power Factor 5 5 90 5 70 9 0 7 7 7 5 5
More informationACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE
ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE hvgrid-tech designs and manufactures high voltage cable accessories for all types of cable systems, ranging from 69 kv to
More information1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide
1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationTransformer bushings, type GOH. Technical guide
Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required
More informationS&C Type XS Fuse Cutouts
S&C Type XS Fuse Cutouts Outdoor Distribution (4.16 kv through 25 kv) S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection Descriptive Bulletin 351-30 August 25, 2003 Supersedes
More informationPOWER SYSTEMS, INC. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS
CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBITIONS Warranty - Material Chance warrants all products sold by it to be merchantable (as such term is defined in the Uniform Coercial
More informationTechnical Specification
Section - 7 Technical Specification OF 33KV OUTDOOR DROP OUT FUSE CUT-OUT AND FUSE LINK AND 33KV OUTDOOR TYPE SINGLE PHASE METAL OXIDE (ZNO) GAPLESS LIGHTNING ARRESTER 84 7.1. TECHNICAL SPECIFICATION OF
More information