1 Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Applications Ideal for use in chemical and petrochemical plants, such as manufacturers of plastics, paints and thinners; in refineries; and in other process areas where ignitable vapors, dust, moisture and corrosive elements may be present. Suitable for use in wet locations. Features Fixtures operate safely in high ambient temperatures. For example, in Class I areas the 150 W HPS fixture operates at a maximum temperature of +120 C (+248 F) in a +65 C (+149 F) ambient [+100 C (+212 F) temperature in a +40 C (+104 F) ambient]. Arrangement of heat-producing components results in more efficient heat dissipation for cooler fixture operation. Wireless design. Threading of fixture unit onto mounting hood makes electrical connection. Only wiring required is attaching two wires to connection block in mounting hood. Connection block is easily wired: (a) loosen two screws, (b) make wire connections and (c) re-position connection block. Safe, easy servicing without disconnecting any wiring. Wireless fixture unit easily threads off mounting hood for convenient servicing or for immediate replacement with a stand-by unit. Acme double-lead threads speed installation and fixture removal from mounting hood only half as many turns are required as for single-lead threads. The threads do not stick or gall, eliminating the troublesome problems often encountered with single lead threads during fixture unit removal. All threaded joints are flame-tight. Integrally ballasted HID lighting fixtures; separate ballasts not required. Factory sealed. External seals not required. Strategic location of lamp socket in combination with the interior prism design of the glass globe provides optimum light distribution and control. Superior corrosion resistance, with epoxy powder coat finish. Porcelain socket with nickel-plated phosphor bronze screw shell. Assures long trouble-free operation in high ambient areas. Choice of mountings: pendant, ceiling, bracket and stanchion. Fiberglass-reinforced polyester reflectors, in standard dome, deep dome or 30 angle, are ideal in installations where luminaire is subject to exceptionally severe corrosive atmospheres. The high bay aluminum reflector is indicated in installations where mounting height from work plane ranges from 20 feet/6 meters and higher. Optional guards protect globes from damage. Secured to fixture with three screws. Light sources: high pressure sodium, pulse start metal halide or metal halide. HPS is excellent where long lamp life is required. HPS provides high lumens per watt and is less expensive to operate. PSMH/MH is desirable where colors of illuminated areas must be close to natural. PSMH/MH provides better color rendition, increased lumen output, longer lamp life, and faster restrike after momentary power interruption. A wide range of ballasts and voltages are available for both domestic and export applications. Ballasts operate at low temperatures PSMH: -29 C (-20 F); HPS: -40 C (-40 F); MH: -35 C (-31 F). 50 W through 150 W high pressure sodium ballasts are high reactance, high power factor type. Standard Materials Ballast bodies and guards: copperfree (4/10 of 1% max.) aluminum Pendant mounting hoods: diecast copperfree (4/10 of 1% max.) aluminum Ceiling, bracket and stanchion mounting hoods: sand cast copperfree (4/10 of 1% max.) aluminum Reflectors: aluminum or fiberglass reinforced polyester Standard Finishes Ballast bodies, guards and mounting hoods: epoxy powder coat finish, electrostatically applied for complete, uniform corrosion protection Options Fuses for field installation can be ordered by catalog number from fuse kit table. Quartz Auxiliary Emergency Lamp for PSMH/MH and HPS fixtures. Relay switch installed in fixture. Add suffix -E to fixture catalog number. Hot Restrike Option available for 50 W through 150 W HPS only. Add suffix R. Smart Starter Option available for 50 W through 400 W HPS and PSMH/MH. Add suffix S. NEC/CEC Certifications and Compliances UL Standard: UL 1598, UL 844 UL Listed: E10444 CSA Standard: C22.2 No. 250, C22.2 No. 137 CSA Certified: Quartz Auxiliary Emergency Lamps for PSMH/MH and HPS fixtures are for ordinary locations only. 348

2 Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Classified Area Suitability of Code Master 2 Series HID Fixtures Suitability includes use of reflector Lamp Type High Pressure Sodium Pulse Start Metal Halide Metal Halide Class I, Division 1 and 2 With Globe or with Globe and Reflector UL/NEC/CEC Temp. Ident. No. Class II, Division 1 and 2 With Globe or with Globe and Reflector UL/NEC/CEC Temp. Ident. No. Lamp Supply Wire Ambient Temp NEC CEC Watts C ( F ) C ( F ) Nameplate Marking Groups Groups Nameplate Marking Groups (140) 40 (104) T6 C,D B, C, D T4 E,F,G (167) 55 (131) T5 C,D B, C, D (185) 65 (149) T5 C,D B, C, D (140) 40 (104) T6 C,D B, C, D T4 E,F,G (167) 55 (131) T5 C,D B, C, D (185) 65 (149) T5 C,D B, C, D (140) 40 (104) T5 C,D B, C, D T4 E,F,G (167) 55 (131) T5 C,D B, C, D (185) 65 (149) T4A C,D B, C, D (140) 40 (104) T5 C,D B, C, D T3A E,F (167) 55 (131) T4A C,D B, C, D T (167) 40 (104) T3C C,D B, C, D (167) 55 (131) T3C C,D B, C, D (185) 40 (104) T3C C,D B, C, D (167) 40 (104) T4 C,D B, C, D T3C E,F,G (167) 40 (104) T4 C,D B, C, D T3A E,F (167) 40 (104) T3C C,D B, C, D (167) 40 (104) T3C C,D B, C, D (167) 40 (104) T3C C,D B, C, D (167) 40 (104) T4 B, C, D T3C E, F, G (167) 40 (104) T4 B, C, D T3A E, F (167) 40 (104) T3C B, C, D T Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations. T Number T T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp. Range ( C) Temp. Range ( F) NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National Electrical Code and the Canadian Electrical Code. Applies to Code Master 2 only. Mercury vapor and metal halide luminaires are not available for purchase within the United States. Please check with your countries governing legislation regarding allowable lamp types before ordering. 349

3 . Groups C and D Applications Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH. Lamp Watts Pendant One Hub, Rigid or Flexible Mounting Ceiling Four Hubs, Three Close-Up Plugs ANSI Lamp Type Catalog Number Hub Size HPS PSMH (Inches) HPS PSMH 50 S68 70 S S S M S50 M M M S51 M S68 70 S S S M S50 M M M S51 M155 3/4 CLP CLP5010 3/4 CLP CLP7010 3/4 CLP CLP1010 3/4 CLP CLP1510 3/4 CPP CPP1710 3/4 CLP2575 CPP CLP2510 CPP2510 3/4 CPP CPP3210 3/4 CPP CPP3510 3/4 CLP4075 CPP CLP4010 CPP4010 3/4 CLC CLC5010 3/4 CLC CLC7010 3/4 CLC CLC1010 3/4 CLC CLC1510 3/4 CPC CPC1710 3/4 CLC2575 CPC CLC2510 CPC2510 3/4 CPC CPC3210 3/4 CPC CPC3510 3/4 CLC4075 CPC CLC4010 CPC4010 Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative. Add voltage suffix -MT for -120/208/240/277 V; or -480 for 480 V. To order fixture with guard, add suffix -G (before adding voltage suffix). Shaded items are suitable for Class I, Group D ONLY. 350

4 . Groups C and D Applications Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH. Bracket - Four Hubs, Three Close-Up Plugs 25 Stanchion - One Hub Lamp Watts ANSI Lamp Type Catalog Number Hub Size HPS PSMH (Inches) HPS PSMH 50 S68 70 S S S M S50 M M M S51 M155 3/4 CLB CLB5010 3/4 CLB CLB7010 3/4 CLB CLB1010 3/4 CLB CLB1510 3/4 CPB CPB1710 3/4 CLB2575 CPB CLB2510 CPB2510 3/4 CPB CPB3210 3/4 CPB CPB3510 3/4 CLB4075 CPB CLB4010 CPB S68 1-1/4 or 1-1/2 CLS S62 1-1/4 or 1-1/2 CLS S54 1-1/4 or 1-1/2 CLS S55 1-1/4 or 1-1/2 CLS M /4 or 1-1/2 CPS S50 M /4 or 1-1/2 CLS25150 CPS M /4 or 1-1/2 CPS M /4 or 1-1/2 CPS S51 M /4 or 1-1/2 CLS40150 CPS40150 Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative. Add voltage suffix -MT for -120/208/240/277 V; or -480 for 480 V. To order fixture with guard, add suffix -G (before adding voltage suffix). 1-1/2 tapped hub furnished with 1-1/2 to 1-1/4 reducer. Shaded items are suitable for Class I, Group D ONLY. 351

5 . Groups B, C and D Applications Integrally Ballasted. 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Lamp Watts Pendant One Hub, Rigid or Flexible Mounting Ceiling Four Hubs, Three Close-Up Plugs ANSI Lamp Type Hub Size Catalog Number HPS PSMH MH (Inches) HPS PSMH MH 70 S S S M152 M S50 M153 M M M S51 M155 M59 70 S S S M152 M S50 M153 M M M S51 M155 M59 3/4 CLP7075TTCN 1 CLP7010TTCN 3/4 CLP1075TTCN 1 CLP1010TTCN 3/4 CLP1575TTCN 1 CLP1510TTCN 3/4 CPP1775TTCN CHP1775TTCN 1 CPP1710TTCN CHP1710TTCN 3/4 CLP2575TTCN CPP2575TTCN CHP2575TTCN 1 CLP2510TTCN CPP2510TTCN CHP2510TTCN 3/4 CPP3275TTCN 1 CPP3210TTCN 3/4 CPP3575TTCN 1 CPP3510TTCN 3/4 CLP4075TTCN CPP4075TTCN CHP4075TTCN 1 CLP4010TTCN CPP4010TTCN CHP4010TTCN 3/4 CLC7075TTCN 1 CLC7010TTCN 3/4 CLC1075TTCN 1 CLC1010TTCN 3/4 CLC1575TTCN 1 CLC1510TTCN 3/4 CPC1775TTCN CHC1775TTCN 1 CPC1710TTCN CHC1710TTCN 3/4 CLC2575TTCN CPC2575TTCN CHC2575TTCN 1 CLC2510TTCN CPC2510TTCN CHC2510TTCN 3/4 CPC3275TTCN 1 CPC3210TTCN 3/4 CPC3575TTCN 1 CPC3510TTCN 3/4 CLC4075TTCN CPC4075TTCN CHC4075TTCN 1 CLC4010TTCN CPC4010TTCN CHC4010TTCN Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V. These voltage suffixes have CSA Certification only. To order fixture with guard, add suffix -G (before adding voltage suffix). Mercury vapor and metal halide luminaires are not available for purchase within the United States. Please check with your countries governing legislation regarding allowable lamp types before ordering. Shaded items are suitable for Class I, Group D ONLY. 352

6 . Groups B, C and D Applications Integrally Ballasted. 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. ANSI Lamp Type Hub Catalog Number Lamp Watts HPS PSMH MH Size (Inches) HPS PSMH MH Bracket - Four Hubs, Three Close-Up Plugs 70 S62 3/4 CLB7075TTCN 1 CLB7010TTCN 100 S54 3/4 CLB1075TTCN 1 CLB1010TTCN 150 S55 3/4 CLB1575TTCN 1 CLB1510TTCN 175 M152 M57 3/4 CPB1775TTCN CHB1775TTCN 1 CPB1710TTCN CHB1710TTCN 250 S50 M153 M58 3/4 CLB2575TTCN CPB2575TTCN CHB2575TTCN 1 CLB2510TTCN CPB2510TTCN CHB2510TTCN 320 M154 3/4 CPB3275TTCN 1 CPB3210TTCN 350 M131 3/4 CPB3575TTCN 1 CPB3510TTCN 400 S51 M155 M59 3/4 CLB4075TTCN CPB4075TTCN CHB4075TTCN 1 CLB4010TTCN CPB4010TTCN CHB4010TTCN 25 Stanchion - One Hub 70 S62 1-1/4 or 1-1/2 CLS70150TTCN 100 S54 1-1/4 or 1-1/2 CLS10150TTCN 150 S55 1-1/4 or 1-1/2 CLS15150TTCN 175 M152 M57 1-1/4 or 1-1/2 CPS17150TTCN CHS17150TTCN 250 S50 M153 M58 1-1/4 or 1-1/2 CLS25150TTCN CPS25150TTCN CHS25150TTCN 320 M /4 or 1-1/2 CPS32150TTCN 350 M /4 or 1-1/2 CPS35150TTCN 400 S51 M155 M59 1-1/4 or 1-1/2 CLS40150TTCN CPS40150TTCN CHS40150TTCN Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V. These voltage suffixes have CSA Certification only. To order fixture with guard, add suffix -G (before adding voltage suffix). Mercury vapor and metal halide luminaires are not available for purchase within the United States. Please check with your countries governing legislation regarding allowable lamp types before ordering. 1-1/2 tapped hub furnished with 1-1/2 to 1-1/4 reducer. Shaded items are suitable for Class I, Group D ONLY. 353

7 Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mounting Hoods Pendant One Hub Hub Size (Inches) Catalog Number 3/4 CAP-75 1 CAP-100 Ceiling Four Hubs, Three Close-Up Plugs Bracket Four Hubs, Three Close-Up Plugs 25 Stanchion One Hub 3/4 CAC-75 1 CAC-100 3/4 CALB-75 1 CALB /4 or 1-1/2 CAS-150 Mounting Adapter with Connection Block Permits use of existing A-51 mounting hoods (AAC Ceiling or AALB Bracket) with the new Code Master 2 Fixture Unit. After removing existing fixture unit and adapter, screw in the new CMAD-1 Adapter. Then thread new fixture unit into the CMAD-1. CMAD-1 Fixture Units Ballast body with globe. Indicate voltage desired by adding voltage suffix to fixture unit catalog number listed below. Lamp Fixture Unit Add Voltage Suffixes Type Watts Number 120/208/240/ /277/ V High Pressure Sodium High Power Factor (Min. P.F. 90%) Pulse Start Metal Halide Constant Wattage (Min. P.F. 90%) Metal Halide Constant Wattage (Min. P.F. 90%) 50 CMBL50 MT TTCN 70 CMBL70 MT TTCN CMBL100 MT TTCN CMBL150 MT TTCN CMBL250 MT TTCN CMBL400 MT TTCN CMBP175 MT TTCN CMBP250 MT TTCN CMBP320 MT TTCN CMBP350 MT TTCN CMBP400 MT TTCN CMBH175 MT TT C6 250 CMBH250 MT TT C6 400 CMBH400 MT TT C6 1-1/2 Tapped hub furnished with 1-1/2 to 1-1/4 reducer. Add suffix -R for Hot Restrike and -S for Smart Starter options. Change voltage suffix -TTCN to -MTCN for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V. These voltage suffixes have CSA Certification only. Mercury vapor and metal halide luminaires are not available for purchase within the United States. Please check with your countries governing legislation regarding allowable lamp types before ordering. Shaded items are suitable for Class I, Group D ONLY. 354

8 Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Polyester Reflectors 50 W W Standard Dome Deep Dome 30 Angle Description Catalog Number CMR-4ST CMR-4DD CMR-4AN Aluminum High Bay Reflectors 50 W W Prismatic Glass Globes 50 W W CMR-4HB 50, 70, 100, 150 W HPS; 175, 250 W PSMH; 175, 250 W MH CGL , 400 W HPS; 320, 350, 400 W PSMH; 400 W MH CGL-400 Aluminum Guards 50 W W 50, 70, 100, 150 W HPS; 175, 250 W PSMH; 175, 250 W MH CGU2 250, 400 W HPS; 320, 350, 400 W PSMH; 400 W MH CGU4 Replacement Sockets 50 W W (Mogul Base) For all Code Master 2 HID fixtures Connection Block 50 W through 400 W For all Code Master 2 HID fixtures CMS-400 VPT-7 Quartz Emergency Option for Pulse Start Metal Halide and High Pressure Sodium Fixtures Fixtures can be supplied with a socket to accept a 150 W or 250 W, 120 V quartz lamp (lamp not included). This D.C. bayonet base socket is in addition to the standard lamp socket, independent of the lighting fixture voltage. Add suffix -E HPS Hot Restrike Restrikes HPS lamp immediately when power is restored after a momentary power interruption. Optional for fixture watts of 50, 70, 100 or 150 (HPS only) Add suffix -R HPS Smart Starter Smart Starter is for HPS fixtures only. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally start lamp. Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by prolonged operation with cycling or failing lamps and simplifies finding their location which reduces maintenance and repair costs. Optional for all HPS fixtures. Add suffix -S 355

9 Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Ballast Amps Fuse Kit Catalog Number Lamp High Pressure Sodium Pulse Start Metal Halide Super CWA Metal Halide CWA Fuse Quantity Watts Volts Start Operating Start Operating Start Operating Required HPS PSMH MH CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF-5 CF CF-3 CF CF-3 CF CF-2 CF CF-2 CF CF CF-8 CF-8 CF CF-5 CF-5 CF CF-5 CF-5 CF CF-5 CF-3 CF CF-5 CF-3 CF CF-2 CF CF CF CF CF CF CF CF CF CF CF CF CF CF-15 CF-10 CF CF-8 CF-8 CF CF-5 CF-5 CF CF-5 CF-5 CF CF-5 CF-5 CF CF-5 CF-3 Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 and 277 V, and 2 fuses for 208, 240 and 480 V. CF-2 = 2 amp; CF-3 = 3 amp; CF-5 = 5 amp; CF-6 = 6 amp; CF-8 = 8 amp; CF-10 = 10 amp 50 through 150 W HPS have H.P.F. High Reactance ballasts; 250 W and 400 W HPS have CWA ballasts. Mercury vapor and metal halide luminaires are not available for purchase within the United States. Please check with your countries governing legislation regarding allowable lamp types before ordering. 356

10 Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Dimensions in Millimeters (Inches) mm (4.58") W W Pendant Ceiling Bracket 25 Stanchion Hub for 3/4" or 1" NPT Conduit C 99.3 mm (3.91") mm (9.86").390º Slot four Places Hub for 3/4" or 1" NPT Conduit A B mm (4.00") mm (5.92") C 45º mm (4.50") 23.9 mm (0.94") mm (4.00") mm (9.86") D mm 2 (4.92" 2 ) 99.6 mm (3.92") 10.4 mm (0.41") Ø Four Holes Hub for 3/4" or 1" NPT Conduit mm (5.50") mm (9.86") 62.5 mm (2.46") 57.9 mm (2.28") 31.2 mm (1.23") 87.9 mm (3.46") mm (11.5") mm (13.75") 50.8 mm (2.00") Ø Wiring Access Cover, Both Sides C B A D 45.5 mm (1.79") mm (4.25") 60.5 mm (2.38") Ø 25º mm (9.5") mm (6.10") Pendant Ceiling Bracket 25 Stanchion A B C D A B C D A B C D A B C (21.50) (24.50) (20.50) (23.50) (12.00) (12.00) (17.61) (20.36) (21.61) (24.36) (20.61) (20.36) (12.00) (12.00) (17.61) (20.36) (21.86) (24.61) (20.86) (23.61) (17.50) (17.50) (17.61) (20.36) C (19.50) (22.20) 25º 60.5 mm (4.5") Ø B (18.70) (21.20) Fixture and Accessory Weights kg (lb) Fixture Size Fixture Weight Reflector Weight Guard Weight 50 W through 175 W 14.5 (31.97) 1.4 (3.09) 0.5 (1.10) 250 W PSMH/MH 16.9 (37.26) 1.4 (3.09) 0.5 (1.10) 250 W HPS 18.1 (39.90) 1.4 (3.09) 0.9 (1.98) 320 W, 350 W and 400 W PSMH, 400 W MH 20.4 (44.97) 1.4 (3.09) 0.9 (1.98) Mounting Hood Weights kgs (lbs) Pendant Ceiling Bracket Stanchion 0.9 (2) 1.8 (4) 2.7 (6) 0.9 (2) Reflector Dimensions in Millimeters (Inches) Standard Deep Dome 30 Angle High Bay " mm (11.23) 10.56" mm (10.56) (10.96) (10.56) A (16.00) (17.50) (6.02) (7.12) (13.30) 127 (5.00) (9.75) " (18.70) mm " 515.6mm (20.30) (20.80) (16.16) 50, 70, 100 and 150 W HPS; 175 W PSMH; 175 and 250 W MH. 250 and 400 W HPS; 250, 320, 350, and 400 W PSMH; 400 W MH. 357

11 * Photometric data is based on a 100-watt clear HPS lamp (9,500 lumens). For candlepower values of fixtures with other lamps, use the following multipliers: 50 W HPS 0.42 (4,000 lumens); 70 W HPS 0.61 (6,300 lumens); and 150 W HPS 1.68 (16,000 lumens). Photometric Data Total Luminaire Efficiency = 76.4% CIE Type - Semi-Direct REPORT NUMBER: CL10G Lamps: 100 W High Pressure Sodium with Globe only Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 Diagonal 2.84 % Ceiling Rcc Zone Lumens Zonal Lumen Summary Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture Total Luminaire Efficiency = 71.3% CIE Type - Direct REPORT NUMBER: CL10ST Lamps: 100 W High Pressure Sodium with Standard Dome Reflector Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 Diagonal 1.66 % Ceiling Rcc Zone Lumens Zonal Lumen Summary Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture

12 * Photometric data is based on a 100-watt clear High Pressure Sodium lamp (9,500 lumens). For candlepower values of fixtures with other lamps, use the following multipliers: 50 W HPS 0.42 (4,000 lumens); 70 W HPS 0.61 (6,300 lumens); and 150 W HPS 1.68 (16,000 lumens). Photometric Data Total Luminaire Efficiency = 61.9% CIE Type - Direct REPORT NUMBER: CL10AN Lamps: 100 W High Pressure Sodium with 30 Angle Dome Reflector Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 Diagonal 1.50 % Ceiling Rcc Zone Lumens Zonal Lumen Summary Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture Total Luminaire Efficiency = 37.8% CIE Type - Direct REPORT NUMBER: CL10DD Lamps: 100 W High Pressure Sodium with Deep Dome Reflector Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 Diagonal 1.54 % Ceiling Rcc Zone Lumens Zonal Lumen Summary Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture

13 * Photometric data is based on a 400-watt clear Pulse Start Metal Halide lamp (34,000 lumens). For candlepower values of fixtures with other lamps, use the following multipliers: 400 W HPS 1.13 (50,000 lumens); and 250 W HPS 0.68 (30,000 lumens). Photometric Data Total Luminaire Efficiency = 81.9% CIE Type - General Diffuse REPORT NUMBER: CP40G Lamps: 400 W Pulse Start Metal Halide with Globe only Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 % Ceiling Rcc Zone Lumens Zonal Lumen Summary Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture Total Luminaire Efficiency = 70.4% CIE Type - Direct REPORT NUMBER: CP40ST Lamps: 400 W Pulse Start Metal Halide with Standard Dome Reflector Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 Diagonal 1.70 % Ceiling Rcc Zone Lumens Zonal Lumen Summary Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture

14 * Photometric data is based on a 400-watt clear Pulse Start Metal Halide lamp (34,000 lumens). For candlepower values of fixtures with other lamps, use the following multipliers: 400 W HPS 1.13 (50,000 lumens); and 250 W HPS 0.68 (30,000 lumens). Photometric Data Total Luminaire Efficiency = 62.5% CIE Type - Direct REPORT NUMBER: CP40AN Lamps: 400 W Pulse Start Metal Halide with 30 Angle Dome Reflector Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 Diagonal 1.64 % Ceiling Rcc Zone Lumens Zonal Lumen Summary Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture Total Luminaire Efficiency = 69.1% CIE Type - Direct REPORT NUMBER: CP40DD Lamps: 400 W Pulse Start Metal Halide with Deep Dome Reflector Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 Diagonal 1.62 % Ceiling Rcc Zone Lumens Zonal Lumen Summary Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture

15 * Photometric data is based on a 400-watt clear Pulse Start Metal Halide lamp (34,000 lumens). For candlepower values of fixtures with other lamps, use the following multipliers: 400 W HPS 1.13 (50,000 lumens); and 250 W HPS 0.68 (30,000 lumens). Photometric Data Total Luminaire Efficiency = 63.4% CIE Type - Direct REPORT NUMBER: CP40HB Lamps: 400 W Pulse Start Metal Halide with High Bay Reflector Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 Diagonal 1.52 % Ceiling Rcc Zone Lumens Zonal Lumen Summary Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires NEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) Class I, Division

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Applications Ideal for use in chemical and petrochemical plants, such as manufacturers

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers

More information

Lighting: Explosionproof Area HID. Applications. Standard Materials

Lighting: Explosionproof Area HID. Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Applications. Standard Materials

Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof Lighting Induction Code Master 2 Factory Sealed Induction Lighting System NEC/CEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside

More information

G1-1. HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof. Page Description

G1-1. HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof. Page Description HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof 1-1 Code Master 2 with Polyester Reflector Code Master Jr. without Reflector Code Master 2 Floodlight A-51 roup A & B with Porcelain Reflector

More information

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof Code Master 2 Factory Sealed Induction Lighting System Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) NEMA 4X

More information

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options Applications UL Listed for Outside Type (Salt Water). Ideal in Class I, Division 1 and 2 installations in refineries, in pipeline transportation facilities, at drilling rigs and in production facilities

More information

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options Code Master 2 HID Factory Sealed Floodlights NEC: Class 1, Division 1 and 2, Groups C, D Marine Type Electric Fixtures Outside Type (Salt Water) CEC: V Class I, Division 1 and 2, Groups B, C, D Class II,

More information

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit. Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics,

More information

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor Mercmaster III HID 50-250 Watt Luminaires Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical processing and other areas where

More information

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations 1-24 Applications UL listed for marine type electric fixtures--outside type (salt water). Ideal in Class I, Div. 1 and 2 installations in refineries, pipeline transportation facilities; at drilling rigs

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 3/4 CAP-75 1 CAP-100

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 3/4 CAP-75 1 CAP-100 Code Master Jr. HID Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH. Medium Base. For Use with Threaded

More information

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit. UNILETS for Use with Threaded Metal Conduit. Applications Enclosed and gasketed HID lighting fixtures for use in tunnels, walkways, bridges, storage facilities, processing plants, parking lots, foundries,

More information

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) 4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are

More information

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations. A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations SXPJ SERIES HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations S X PJ Class I, Division 1, Group C & D Class II, Division 1, Groups E, F & G Class III Zone 1, Groups IIA & IIB Factory

More information

SXPJ SERIES S X azz.com/rigalite

SXPJ SERIES S X azz.com/rigalite SXPJ SERIES HID Lighting & Compact for Explosion Fluorescent Proof, Lighting Hazardous for and Hazardous Hostile Locations and Hostile Locations S X PJ Class I, Division 1, Group C & D Class II, Division

More information

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations. Areamaster 100 Wide-Beam Floodlights NEC CEC V Class II, Divisions I and 2, Groups E, F, G V Class III Applications Highly efficient, all-weather flood-lighting for lower wattage service. Well suited for:

More information

N2MV Series W Non-metallic

N2MV Series W Non-metallic N2MV Series 50-175W Non-metallic Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence (100W max) Marine & Wet Locations, R, 4, 4X; IP56 L Applications: N2MV series Champ

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures ATEX/IECEx: Zone 2 and 22 II 2 GD Lighting LIGHTING: ENCLOSED AND GASKETED AREA LED/INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial,

More information

Applications. Illustrated Features

Applications. Illustrated Features Applications For use in locations where a high degree of corrosion resistance is required. FR Series: For use in areas where high humidity or water vapor are present Typical uses include meat- or food-processing

More information

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations Applications For use in hazardous locations defined by the NEC and CEC as Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Marine Outdoor Salt Water; UL1598A and. As well

More information

Areamaster LED Flood/High Bay Luminaires

Areamaster LED Flood/High Bay Luminaires Applications Typical applications include: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust,

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

F1-1. HID Lighting: Enclosed and Gasketed. Description. 2, 3 Mercmaster III Family Tree Mercmaster III HID Low Profile Lighting Fixtures

F1-1. HID Lighting: Enclosed and Gasketed. Description. 2, 3 Mercmaster III Family Tree Mercmaster III HID Low Profile Lighting Fixtures HID Lighting: Enclosed and Gasketed 1-1 Page Description 2, 3 Mercmaster III amily Tree 2-22 Mercmaster III HID Low Profile Lighting ixtures 23-54 Mercmaster III HID 50-250W Lighting ixtures Mercmaster

More information

DMV Series W For Combustible Dusts

DMV Series W For Combustible Dusts L DMV Series 50-250W For Combustible Dusts Champ H.I.D. Luminaires Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl.

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps. Applications Enclosed and gasketed, non-metallic emergency lighting system suitable for use in areas where flammable gases or vapors may become present due to abnormal, unusual or accidental conditions

More information

Standard Grade 14 Inch Reflector. Ordering Information

Standard Grade 14 Inch Reflector. Ordering Information Job Type Dimensions Specifications B A NRTL/C C Damp Location D E Slick- On Quick- On F A B C D E F 9-1/2" 2" 9-1/2" 20-22/32 24-27/32" 9-7/16" 14-1/4" 241 mm 51 mm 241 mm 536-631 mm 240 mm 362 mm 9-1/2"

More information

MOGUL BASE HID FIXTURES

MOGUL BASE HID FIXTURES KILLARK Z A H LO C MOGUL BASE HID FIXTURES Class I, Div. 1 & 2 Groups C,D Class l, Zone 1 & 2, Groups llb,lla Class l, Zone 1, AEx d IIB Class II, Div. 1 & 2, Groups Class III, Div. 1 & 2 Suitable for

More information

PGL350P W PS Wallpack

PGL350P W PS Wallpack 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PGL350P1281 350W PS Wallpack Hubbell Lighting, Inc. Catalog Number Manufacturer Description Weight per unit Product Category

More information

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1, Groups E, F, G Class II Division 2, Groups F, G Class III Simultaneous Exposure Type 3R, 4, 4X IP66/67 Applications

More information

AFL FLOODLIGHT SERIES

AFL FLOODLIGHT SERIES AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum

More information

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT MHD2/MHDO SERIES Marine Heavy Duty Outdoor Non-Metallic Fluorescent Non-metallic, glass reinforced polyester housing. 3/4 in. NPT aluminum hub. Captive stainless steel latches. Stainless steel mounting

More information

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent MHD2/MHDO SERIES Marine Heavy Duty Non-Metallic Fluorescent Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844 Hazardous Locations

More information

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109 s s ACS Small Acorn 109 ACL Large Acorn 109 AC3, AC5 Large Type 3 or 5 Acorn 109 BKS Small Buckeye 111 BKL Large Buckeye 111 BK3, BK5 Large Type 3 or 5 Buckeye 111 Small Chestnut 113 Large Chestnut 113

More information

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations WFH LED SERIES W FH High-Bay Lighting for Hazardous & Wet Locations Class I, Division 2, Groups A, B, C, & D Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations

More information

KH Series Kemlux III Enclosed/Gasketed

KH Series Kemlux III Enclosed/Gasketed For use in corrosive, harsh, hazardous applications such as chemical, petrochem, marine, power generation, pharmaceutical, or food processing plants Mogul base socket on tanks C, D & E Medium base socket

More information

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent NEC/CEC: Type 3R, 4X IP66, IP67 Suitable for use in Wet Locations Marine Outside Type (Salt Water) Applications Powerful, efficient weatherproof lighting for applications such as: Security lighting Production

More information

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712 Type No. Catalog No. Job. Name ILXGHB MasterColor Elite Series APPLICATIONS Applications include industrial facilities, manufacturing plants, retail applications, and gymnasiums. CONSTRUCTION The ILX MasterColor

More information

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations MHDS SERIES Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 198A Marine

More information

INCANDESCENT/COMPACT FLUORESCENT/MEDIUM BASE HID

INCANDESCENT/COMPACT FLUORESCENT/MEDIUM BASE HID KILLARK INCANDESCENT/COMPACT FLUORESCENT/MEDIUM BASE HID Class I, Div. 1 & 2, Groups C,D Class I, Zones 1 & 2, Groups llb, lla Class II, Div. 1 & 2, Groups E,F,G Class III, Div. 1 & 2 Suitable for wet

More information

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1 Job Type Dimensions Specifications B A C NRTL/C Damp Location D Slick-On Quick-On E A B C D E 9-1/2" 2" 9-1/2" 26-11/16" 23-1/8" 241 mm 51 mm 241 mm 678 mm 587 mm 9-1/2" 1-1/8" 8-5/8" 25-13/16" 23-1/8"

More information

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments WFHN LED SERIES High-Bay Lighting for Heavy Hose-Down Environments UL 1589 Wet Locations UL 8750 LED Safety NEMA 4X CUL Listed NSF Certified Food Equipment High Pressure Hose-Down One Piece Welded Aluminum

More information

Perimaliter Wallpacks

Perimaliter Wallpacks ENERGY SAVING Outdoor Lighting Perimaliter Wallpacks Perimaliter III PVL3 / PGM3 Perimaliter II PGL Solutions for Perimeter/Area Lighting Perimaliter Wallpacks The Perimaliter wallpack has been the design

More information

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire SAFR LED SERIES Hazardous Location LED Luminaire Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Class I, Zone 2, Groups IIA, IIB & IIC UL 8750 LED Safety UL 844

More information

MAR SERIES Fluorescent Lighting for Hazardous Locations

MAR SERIES Fluorescent Lighting for Hazardous Locations MAR SERIES M AR Fluorescent Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C, & D Seismic Tested UL 844 Hazardous Locations UL 924 Emergency Lighting UL 1598A Marine Outside Type CSA

More information

Fluorescent Lighting: Enclosed and Gasketed

Fluorescent Lighting: Enclosed and Gasketed luorescent Lighting: Enclosed and Gasketed 3-1 Page Description 2-5 V Series 2-3 eatures, Ordering Information and Accessories 4-5 Technical Data, Dimensions and Photometric Data 6-11 VRS and DRS luorescent

More information

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED SAFJ LED SERIES Hazardous Location Compact LED Class I, Division 2, Groups A, B, C, & D Class II, Division 1 & 2, Groups E & F Class III Simultaneous Presence Enclosed & Gasketed Wet Locations NEMA 3R,

More information

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount 220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount Part #: HAL-PRM-250W-HPS-220V-PT Page: 1 Made in the USA The efficient HAL-PRM-250W-HPS-220V-PT high pressure sodium

More information

Champ Fixtures. Class I, Division 2 Class I, Zone 2. Floodlight

Champ Fixtures. Class I, Division 2 Class I, Zone 2. Floodlight Champ Fixtures Class I, Division Class I, Zone Floodlight Champ Floodlight Fixtures Whenever Cooper Crouse-Hinds develops a new product, system, or procedure, we focus on one overriding question: Will

More information

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl Catalog Number Manufacturer Description Weight per unit Product

More information

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens 1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens Part #: HALPRM-1000WMH Made in the USA The extremely durable Larson Electronics HALPRM-1000WMH metal halide

More information

Industrial Mercmaster LED Low Profile Luminaires For Ordinary Locations

Industrial Mercmaster LED Low Profile Luminaires For Ordinary Locations Type R, 4, 4X Marine Outside Type (Salt Water) For USA ONLY Applications Ordinary location fixtures suitable for use in: Heavy industrial locations where severe weather conditions, excessive moisture,

More information

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +

More information

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series Low brightness and uplighting combine to create a pleasing visual environment Softbay Series Keene MAKES LIGHT WORK Softbay is a durable performer in light-to-moderate industrial environments and an enduring

More information

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors

More information

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.

More information

COMPACT FLUORESCENT EMERGENCY FIXTURES

COMPACT FLUORESCENT EMERGENCY FIXTURES KILLARK H A Z LO C COMPACT FLUORESCENT EMERGENCY FIXTURES VE3Q/VE4Q Class I, Div. 2, Groups A,B,C,D Class l, Zone 2, Groups IIC, llb, lla Class II, Div. 1 & 2, Groups E,F,G Class III NEMA 3, 4, 4X IP66

More information

TORNADOTM BOLLARD PATENTS PENDING

TORNADOTM BOLLARD PATENTS PENDING TORNADOTM BOLLARD PATENTS PENDING Day Tornado Bollard Unlike any bollard available in today s specification pallet, Tornado offers a new form and character for pedestrian scale lighting. Tornado adds an

More information

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812 Type No. Catalog No. Job. Name WL Series APPLICATIONS Applications include low ceiling applications, light industrial manufacturing facilities, offices, lobbies, conference rooms, food processing plants,

More information

KAD250MR3TBSPD04 Wall Fixture

KAD250MR3TBSPD04 Wall Fixture 8 South Street 796-76, TX Nacogdoches Phone: 96-69-79 Fax: 96-6-68 AllenWatson@elliottelectric.com MRTBSPD Wall Fixture Catalog Number MRTBSPD Manufacturer Description Area Light, Metal Halide Lamp; Lamp

More information

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S T A B L E O F C O N T E N T S A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S LLF755 - Low Level Flood with Anti-Glare Faceplate C1.1 LLF800 - Low Level Flood with Anti-Glare Faceplate

More information

Perimaliter Wallpacks

Perimaliter Wallpacks Perimaliter Wallpacks Perimaliter III PVL3 / PGM3 Perimaliter II PGL Solutions for Perimeter/Area Lighting Perimaliter Wallpacks The Perimaliter wallpack has been the design leader in refractor wallpacks

More information

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120 Aerolume Collection Area Luminaires Fixture Sizes 70-00W HID 64/80/ Overview Mini-Aerolume Aerolume Aerolume-G 1." (4.9mm) 18" (47.mm) " (84.mm) 6." (16.1mm) 19" (48.6mm) 4" (1.4mm) 8" (0.mm) " (84.mm)

More information

Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L

Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L Part #: EPL-48-2L-T12VHO Made in the USA The Larson Electronics EPL-48-2L-T12VHO Explosion Proof Fluorescent

More information

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations LED Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Class I, Zone 2, Groups IIA, IIB & IIC UL 8750 LED Safety UL 844 Hazardous Locations UL 598 Wet Locations UL

More information

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area. Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics Voltage Mounting Options Finish (Reflector) (Factory Installed) Overall Dimensions 16 (40.6 cm) 8.9 (22.5 cm) Weight (maximum) 20.5 (52.07

More information

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

Induction Compact Fluorescent HID LPQ. Canopy Luminaire Induction Compact Fluorescent HID LPQ Canopy Luminaire LPQ Series Lighting For Life Featuring the Philips QL Induction Lighting System 100,000 Hours of Operation Very Low Maintenance Efficient Operation

More information

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications

More information

Champ MLL LED luminaires

Champ MLL LED luminaires The Champ MLL linear LED is specifically designed to replace fluorescent T12, T8 and T5HO lighting in harsh and hazardous applications. The rugged and durable design features the industry s most versatile

More information

Haz. HazMax Summit/ss TECHNICAL SPECIFICATIONS

Haz. HazMax Summit/ss TECHNICAL SPECIFICATIONS Haz HazMax Summit/ss APPLICATIONS High, mid & low bay Petrochemical facilities Hazardous locations Munitions manufacturing and storage Watertight requirements Waste water treatment plants Dusttight requirements

More information

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp 45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp Part #: EPL-48-2L-45D Made in the USA The Larson Electronics EPL-48-2L-45D Explosion Proof Fluorescent

More information

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket. U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications

More information

Cynergy Series Retrofit Kit

Cynergy Series Retrofit Kit project: fixture type: catalog #: quantity: The Cynergy Series LED Retrofit system has been developed to dramatically improve existing recessed troffer performance using Solid State Lighting (SSL) technologies.

More information

DESCRIPTION Galleria's beauty and versatility make it an excellent choice for roadway and general area lighting applications. An aesthetic reveal in the formed aluminum housing gives the Galleria a distinctive

More information

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B 150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B Part #: HBLP-REMG-1MLED-B-PND Page: 1 Made in Texas The Larson Electronics HBLP-REMG-1MLED-B-PND LED

More information

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description: Project Number Date 15.00487 3/26/2015 LAB 6 Test Sample Description Catalog Number: Description: P3408-0930K9 Close to Ceiling fixture Test Method: Preburn Time: Time To Stabilize: Total Operating Time:

More information

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly

More information

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens Part #: EPL-HB-25LED-RT Page: 1 The Larson Electronics EPL-HB-25LED-RT Explosion Proof High Bay light

More information

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. : Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide

More information

OP2 CosmoPolis Series

OP2 CosmoPolis Series Catalog Number: Approvals: - - - - - Series/Source-Wattage Optics E ballast Voltage Mounting Options Finish (Factory Installed) Accessories (Field Installed) Date: Page of 6 Overall Dimensions OP2 arm

More information

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS XPF XPFMax Performer/al APPLICATIONS, II & III Division 1 explosive atmospheres High, mid & low bay Fuel dispensing facilities Paint booths Marine and watertight requirements Paint & formulation facilities

More information

DESCRIPTION & APPLICATION

DESCRIPTION & APPLICATION T5 FME T5 4L - Full Body High Bay DESCRIPTION & APPLICATION The Envirobrite FME T5 fixture is a full body fluorescent high bay ideal for replacing energy devouring HID fixtures. This all aluminum enclosed

More information

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS Champ Fluorescent Luminaires DMVFB Auxiliary Series - 52, 64, & 84 Watt Installation & Maintenance Information SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IF 1713 IMPORTANT SAFEGUARDS READ AND FOLLOW

More information

HID/AREA: NEC/CEC ENCLOSED AND GASKETED. Applications

HID/AREA: NEC/CEC ENCLOSED AND GASKETED. Applications High Pressure Sodium, Pulse Start Metal Halide and Metal Halide Listed for simultaneous exposure to combustible dusts and flammable gases or vapors. Applications Enclosed and gasketed fixtures suitable

More information

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor Mercmaster III HID 50-250 Watt Luminaires High Pressure Sodium and Pulse Start Metal Halide Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial,

More information

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect

More information

Overall Dimensions. Specifications

Overall Dimensions. Specifications Overall Dimensions EFX B EFX VM Vertical Mount C 13 housing (70-400W) 19 housing (450-1000W) E D H B C D E 13.3 16.8 16.2 7.0 9.8 (33.78cm) (42.67cm) (41.15cm) (17.78cm) (24.89cm) F G H I J 22.2 11.3 6.3

More information

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations PREDATOR The Predator floodlight offers versatility, efficiency, and performance, which provides a unique solution to a variety of lighting needs. With the Predator, Holophane continues its legacy of utilizing

More information

ELA Low Wattage HID Series Element Acrylic High Bay, W HID

ELA Low Wattage HID Series Element Acrylic High Bay, W HID Type No. Catalog No. Job. Name APPLICATIONS Applications include large and small retail facilities, lobbies, conference rooms, auditoriums and other commercial and light industrial spaces. CONSTRUCTION

More information

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC 1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC Part #: MHFL-1000W Made in the USA The powerful and efficient MHFL-1000W metal halide light fixture from Larson

More information

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP051A0712

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP051A0712 Type No. Catalog No. Job. Name PFCB Series APPLICATIONS Applications include assembly areas, industrial facilities, and warehouses. CONSTRUCTION Low profile, heat dissipating die-cast aluminum ballast

More information

www.greenelectricalsupply.com Page 1 of 4 The HLR SERIES hazardous location family of fixtures is suitable for use in a wide range of indoor and outdoor Class I Division 2 applications. Available in eight

More information

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel Part #: HAL-48-2L-LED-BMSW-G2 Page: 1 Made in the USA The Larson Electronics HAL-48-2L-LED-BMSW-G2 Hazardous

More information

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions ! CAUTION All wiring should be done by a licensed electrician in accordance with state codes, local codes and National Electric Code (NEC) standards. Improper installation may result in serious injury

More information