Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Size: px
Start display at page:

Download "Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents"

Transcription

1 Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures ( A) IP (Type /X/) Selection of metal enclosures ( A) IP (Type ) IP (Type //) Bimetallic Class overload relays Solid-state overload relays Compact design Meets international standards Bulletin enclosed starters are designed using Bulletin contactors ( A) and Bulletin bimetallic (Class ) or solidstate overload relays in a metal or molded plastic enclosure. Your order must include: Cat. No. of the starter selected, coil voltage code, overload relay suffix code, and, if required, factory-installed modifications suffix code and/or cat. no. of any accessories. Table of Contents Product Selection... this page Accessories... - Modifications... - Approximate Dimensions... - Standards Compliance EN/IEC -- VDE CSA C. No. UL Certifications culus Listed (File E, Guide NLDX, NLDX) Molded Plastic Enclosures Product Selection AC-Operated Starters Enclosed Type Molded Plastic Ratings (AC, AC) With START (Green) kw Hp and STOP (Raised Red) Push Buttons With RESET (Blue) Push Button -Phase -Phase -Phase Max I e [A] V/V V V V V V V V Cat. No. Cat. No. IP (EN/IEC Only) ABS V- Molded Plastic Enclosure (Cat. No. E-AS) / -/ -/.. -CV EC- -CV EC- / -/ -/. -CV ED- -CV ED- -/ / -/. -CV ED- -CV ED- -/. -CV ED- -CV ED- -/. -CV EE- -CV EE- IP (Type, X, K) Watertight, Dustight Corrosion-Resistant Small Molded Plastic Enclosure (Cat. No. E-CS) / -/ -/.. -CK EC- -CK EC- / -/ -/. -CK ED- -CK ED- -/ / -/. -CK ED- -CK ED- -/. -CK ED- -CK ED- -/. -CK EE- -CK EE- With START/STOP Multifunction Push Button ( Functions) and Reset IP (Type, X, K) Watertight, Dustight Corrosion-Resistant Large Molded Plastic Enclosure (Cat. No. E-CS) / -/ -/.. -CL EC-M- / -/ -/. -CL ED-M- -/ / -/. -CL ED-M- -/. -CL ED-M- -/. -CL EE-M- -/. -CL EF-M- -/. -CL EF-M- -/. -CL EF-M- Coil Voltage Code The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. -CK ED-M- becomes -CKLDED-M-. [V] Hz Hz D B Hz D B / Hz KJ KF KN - Publication A-CAA-EN-P

2 Bulletin IEC Non-Reversing Starters Accessories/Product Selection Accessories Description E Plus DeviceNet and Protection Module Communicates motor diagnostic data via DeviceNet, includes additional I/O, and provides enhanced motor protection options. E Plus EtherNet/IP and Protection Module Communicates motor diagnostic data via EtherNet/IP, includes additional I/O, and provides enhanced motor protection options. E Plus Jam Protection Module Provides Jam protection with adjustable trip level and trip delay setting. The module also provides an input to allow remote reset of a trip. E Plus Ground Fault Module Provides adjustable ma A ground fault protection. The module also provides an input to allow remote reset of a trip. E Plus Ground Fault/Jam Module Provides adjustable ma A ground fault and fixed jam protection. The module also provides an input to allow remote reset of a trip. E Plus PTC Module Provides terminals for connection up to six PTC thermistor sensors. Sensors react to actual temperature and therefore provide enhanced motor protection. Module also provides an input to allow remote reset of a trip. E Plus Remote Reset Module Provides an input to allow remote reset of a trip. Modifications, including pilot lights and selector switches, are available through the Modified Standards Program. Send Modified Standard quote requests to RADBQuote@ra.rockwell.com. Enclosed Type Sheet Metal Max I e [A] Ratings (AC, AC) IP (Type ) kw Hp General Purpose Sheet Metal Enclosure (Liftoff Cover) -Phase -Phase -Phase V/V V V V V V V Cat. No. IP (Type,, ) Watertight, Dusttight Sheet Metal Enclosure (Hinged Cover) Cat. No. / -/ -/ -CA -CF -/ / -/ -CA -CF -/ -CA -CF -/ -CA -CF -/ -CA -CF -/ -CA -CF -/ -CA -CF -CA -CF -CA -CF -/ -CA -CF Coil Voltage Code The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. - CA becomes Cat. No.-CAB. Cat. No. -EDN -ETN -EJM -EGF -EGJ -EPT -ERR AC Voltage [V] Common Control Hz A T N G B M Coil Voltage Code Hz H L A N B C Separate Control (without transformer) Hz K Y D Coil Voltage Code Hz J X D T Overload Relay Code The Cat. No. as listed is incomplete. Select an overload relay code from page - to complete the Cat. No. Select an overload relay code from E Plus Overload Relay for Ø Applications: Phase Loss Protection, Class or to complete the Cat. No. Bimetal overload relays are not available in molded plastic enclosed starters. When selecting a factory-installed control circuit transformer (see page -), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be V by default. Example: Cat. No. -CFB -P will have a transformer with a V primary/v secondary and a V starter coil. If a starter coil voltage other than V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. -CFBJ -P will have a transformer with a V primary/v secondary and a V starter coil. Control Circuit transformers are not available in molded plastic enclosures Publication A-CAA-EN-P -

3 Bulletin IEC Enclosed Starters Electronic Overload Relay Code Selection Bulletin E Plus electronic overload relay for -phase applications: Selectable Trip Class,,,, selectable manual/auto reset For use with: Bulletin,,,,, E,, and C C C C C C C C Full Load Current Range [A] Phase Overload Relay Code EA EB EC ED EE EE EF C C C EG Bulletin E Plus electronic overload relay for -phase applications: Trip Class only, manual reset C For use with: Bulletin,,,,, E,, and Full Load Current Range [A] -Phase Overload Relay Code.. DA.. DB C C C C.. DC. DD. DE Bulletin E Plus electronic overload relay for -phase applications: Selectable Trip Class,,, ; selectable manual/auto reset For use with: Bulletin C C C C C Full Load Current Range [A] Phase Overload Relay Code EP ER ES ET C C C C C C EU For Bulletin combination starters and Bulletin circuit breaker-type pump control panels only. Consult your local Rockwell Automation sales office or Allen-Bradley distributor for availability and dimensions. Publication A-CAA-EN-P -

4 Bulletin Enclosed Starter Line Accessories For Bulletins,,,, and Red "ON" Pilot Light Full Voltage Type Green Pilot Light Full Voltage Type Description For Use With Bulletin No. Enclosure Type Cat. No. V -PLR V All Metal Lift-off, Metal Hinged, and Molded Plastic -PLR V -PLR V V V V H All Metal Hinged -PLR -PLR -PLR -PLG V All Metal Lift-off, Metal -PLG Hinged, and Molded Plastic V All -PLG Dual "ON" Pilot Light Forward Red Reverse White Full Voltage Type V V, Metal Hinged -PLRW -PLRW Pilot Device Mounting Bracket (required when mounting pilot devices in metal lift-off enclosures), Metal Lift-off -BR Control Circuit Fuse Block For Class CC rejection type fuses (fuses not included) All Metal Lift-off and Metal Hinged -R Grounding Bushing Adapts to / in. N.P.T., PG. & BS mm threads Molded Plastic -GR Single Pole N.O. Auxiliary Contact for Disconnect Switch Closing Button For.mm Round Panel Hole, Metal Hinged -GA All All -N "OFF-ON" Selector Switch -Position Maintained All Metal Lift-off and Metal Hinged -MT Does not include legend plate. See page - for Bulletin F Legend Plate. Legend Plates for use on metal-hinged enclosures only. Requires mounting bracket Cat. No. -BR when using metal lift-off enclosures. An auxiliary contact adaptor, Cat. No. R-AA, is required when installing auxiliary contact, Cat. No. -GA. required for disconnect switch. Publication A-CAA-EN-P -

5 Bulletin Enclosed Starter Line Accessories For Bulletins,,,, and Description "HAND-OFF-AUTO" Selector Switch -Position Maintained, Includes Legend Plate "FORWARD-OFF-REVERSE" Selector Switch -Position Maintained "START-STOP" Push Button Flush green "I/START" Extended red "O/STOP" "START" Push Button Flush green "START" For Use With Bulletin No. Enclosure Type Cat. No.,,,, Metal Lift-off and Metal Hinged -MT H Metal Hinged -MT, Metal Lift-off and Metal Hinged -MT, Metal Lift-off -MS H Metal Hinged -MS All Metal Hinged -MS "ON-OFF" Push Button, Metal Lift-off -MS "FORWARD, REVERSE-STOP" Push Button "STOP" Push Button Flush red "STOP" "ON" Push Button Flush green "ON" "OFF" Push Button Flush red "OFF" Metal Lift-off -MS All Metal Hinged -MS All Metal Hinged -MS All Metal Hinged -MS "FORWARD, REVERSE-STOP" Push Buttons, Metal Hinged -MS "START" Push Button Flush green "START" and "STOP" Push Button Flush red "STOP" H Metal Hinged -MS "RESET" Push Button Wiring Kit for Starters IEC ModCenter Wiring Kit for Transformers IEC ModCenter All Metal Lift-off and Metal Hinged -MR H -WH -W -W H -WT, -WT Requires mounting bracket Cat. No. -BR when using metal lift-off enclosures. Requires reset adapter Cat. No. -RA for -T bimetallic overload relay and reset adapter Cat. No. -ERA for Bulletin E Plus electronic overload relay. - Publication A-CAA-EN-P

6 Bulletin Enclosed Starter Line Modifications Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins with metal enclosures, L) Listed on this and the following pages are factory-installed modifications and special features which are available for the low voltage (V maximum) starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the product Cat. No. Example: Cat. No. -CADAE- Suffix Code Enclosure Design C/C A C/C B C/C C L- C C/C D C C C C C C Description of Modification START-STOP Push Button Metal Lift-off A A A NA A A A A A A A Metal Hinged A A A NA A A A A A A A ON-OFF Push Button E HAND-OFF-AUTO Selector Switch OFF-ON Selector Switch E RUN-Red Pilot Light R A A A NA A A A A A A A RUN-Green Pilot Light G Plastic Lift-off A A A NA A A A A A A A RUN-Yellow Pilot Light Y A A A NA A A A A A A A Red LED Pilot Light (V) R Plastic Lift-off A A A NA A NA NA NA NA NA NA Red LED Pilot Light (V) R Plastic Lift-off A A A NA A NA NA NA NA NA NA Control Circuit Transformer Primary and Secondary Fuse P Provided (Standard Capacity) Plastic Lift-off A A A NA A NA NA NA NA NA NA External Reset Metal Lift-off A A A NA A A A A A A A Metal Hinged A A A NA A A A A A A A Control Circuit Fuse Block Fuses Provided Additional N.O. N.C. (Side Metal Lift-off NA NA NA A NA NA NA NA NA NA NA Mount) Auxiliary Contact on Contactor (L only) Metal Hinged NA NA NA A NA NA NA NA NA NA NA Additional N.O. N.C. (Side Mount) Auxiliary Contact on Contactor Additional N.O. N.C. (Front Mount) Auxiliary Contact on T Contactor With Bulletin F Integrated LED Module. Pilot light is available for control voltages of Vor less. If applicable, seelct a transformer. For starters with molded plastic lift-off enclosures, the voltage of the LED module must equal the starter's coil voltage. Non-Reversing Circuit Breaker Combination Starters (Bulletin ) Description of Modification Suffix Code Enclosure Design C C C C C C C C C C START-STOP Push Button ALL NA NA NA NA A NA A A A NA HAND-OFF-AUTO ALL NA NA NA NA A NA A A A NA Red Pilot Light R ALL NA NA NA NA A NA A A A NA Control Circuit Transformer Primary and Secondary Fuse Provided (Standard P ALL NA NA NA NA A NA A A A NA Capacity) External Reset ALL NA NA NA NA A NA A A A NA Control Circuit Fuse Block Fuses Provided ALL NA NA NA NA A NA A A A NA Additional N.O. - N.C. (Side Mount) Auxiliary Contact on Contactor ALL NA NA NA NA A NA A A A NA Additional N.O. - N.C. (Front Mount) Auxiliary Contact on Contactor T ALL NA NA NA NA A NA A A A NA A=Available Option NA=Not Available When ordering in Canada, use suffix. Primary fusing is not required by the Canadian Electrical Code. Publication A-CAA-EN-P -

7 Bulletin Enclosed Starter Line Modifications Full Voltage Reversing and Multi-Speed Starters (Bulletin with metal enclosures) Description of Modification Suffix Code Enclosure Design C C C C C C C C C C FOR-REV-STOP Push Buttons ( Only) Metal Lift-off A A A A A A A A A NA Metal Hinged A A A A A A A A A A FOR-OFF-REV Selector Switch ( Only) Metal Lift-off A A A A A A A A A NA Metal Hinged A A A A A A A A A A Red FOR/ White REV Pilot Lights ( Only) RW Metal Hinged A A A A A A A A A A A A A A A A A A A A Control Circuit Transformer Primary and Secondary Fuse Provided (Standard Capacity) P ALL A A A A A A A A A A External Reset ( Only) ALL A A A A A A A A A A Control Circuit Fuse Block Fuses Provided ALL A A A A A A A A A A Additional N.O. N.C. (Side Mount) Auxiliary Contact on Each Contactor ALL A A A A A A A A A A Additional N.O. N.C. (Front Mount) Auxiliary Contact on Each Contactor T ALL A A A A A A A A A A Reversing and Non-Reversing Fusible Combination Starters (Bulletins, ) Description of Modification Suffix Code Enclosure Design C C C C C C C C C C START-STOP Push Button ( Only) ALL A A NA A A NA A A A NA FOR-REV-STOP Push Buttons ( Only) ALL A A NA A A NA A A A NA HAND-OFF-AUTO Selector Switch ( Only) ALL A A NA A A NA A A A NA FOR-REV-STOP Selector Switch ( Only) ALL A A NA A A NA A A A NA Red Pilot Light ( Only) R ALL A A NA A A NA A A A NA Red FOR/ White REV Pilot Lights ( Only) RW ALL A A NA A A NA A A A NA Control Circuit Transformer Primary and Secondary Fuse Provided (Standard Capacity) P ALL A A NA A A NA A A A NA External Reset ALL A A NA A A NA A A A NA Fuse Cover For Disconnect Switch ALL A A NA A A NA A A A NA Control Circuit Fuse Block Fuses Provided ALL A A NA A A NA A A A NA N.O. Auxiliary Contact On Disconnect Switch ALL A A NA A A NA A A A NA Additional N.O. N.C. (Side Mount) Auxiliary Contact on Contactor ( Only) ALL A A NA A A NA A A A NA Additional N.O. N.C. (Side Mount) Auxiliary Contact on each Contactor ( Only) ALL A A NA A A NA A A A NA Additional N.O. N.C. (Front Mount) Auxiliary Contact on Contactor ( Only) T ALL A A NA A A NA A A A NA Additional N.O. N.C. (Front Mount) Auxiliary Contact on each Contactor ( Only) T ALL A A NA A A NA A A A NA A=Available Option NA=Not Available Transformer Type. When ordering in Canada, use suffix. Primary fusing is not required by the Canadian Electrical Code. - Publication A-CAA-EN-P

8 Bulletin Enclosed Starter Line Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Bul. Line Starters Approximate Dimensions Bulletin Plastic Lift-Off Enclosure Cat. Nos. E-AS, -AS, -CS, -CS Plastic Enclosures. (.). (.). (.) (.) (.) (.) Ø. (Ø.) Ø. (Ø.). (.) (.) (.) (.) (.) Ø. (Ø.). (.) (.). (.) Cat. Nos. E-CS, -CSR, and -CCR Plastic Enclosures [.] [.]. [.] [.]. [.]. [.]. [.] Ø. [Ø.] Ø [Ø.]. [.]. [.] Ø [Ø.]. [.] [.] [.] [.]. [.] [.] [.] [.] [.] [.] [.] Rotary operator alternatively (for maintained control). [.] [.] Pozidriv No. (. x.). Nm lb-in Cat. No. E-CCR x... mm² x No.... AWG Pozidriv No.. Nm lb-in Publication A-CAA-EN-P -

9 Bulletin Enclosed Starter Line Approximate Dimensions Bulletin Metal Lift-Off Enclosures Type (IP). (.) B C D A F E. (.) dia. For / or M Screw mtg. holes Contactor Size A Height B Width C Depth D E F IP (Type ) General Purpose Metal Lift-Off Enclosure for Bulletin (Without Transformer) C C C C (-/) (-/) () (-/) (-/) (/) C C C C C C C C C C () (-/) () (-/) (-/) (-/) () (-/) () () (-/) (-/) IP (Type ) General Purpose Metal Lift-Off Enclosure for Bulletin (With Transformer) () (-/) (-/) (-/) () (-/) () () (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (/). (/) (/). (/). (/). (/) Publication A-CAA-EN-P -

10 Bulletin Enclosed Starter Line Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Bulletin Metal Hinged Enclosures Type // (IP) Contactor Size A Height B Width C Depth D E F G (dia.) C C C C C C C C C C C C (-/) (//) () (-/) (-/) (-/) () IP (Type //) Metal Hinged Enclosure for Bulletin (Without Transformer) (-/) (-/) () (-/) (-/) (-/) (-/) (-/) (-/) () () (-/) IP (Type //) Metal Hinged Enclosure for Bulletin (With Transformer) (-/) (-/) (-/) () (-/) (-/) (-/) (-/) Bulletins and E Metal Hinged Enclosures Type // (IP) (-/) (-/) (-/) (-/) () () () (-/) (-/) (-/) (/) (-/) (-/) (-/) (/) (/) (/) Contactor Size A Height B Width C Depth D E (Mtg.) F G (dia.) C C C C C C C C C C C C C C (-/) (-/) (//) () (-/) (-/) () () IP (Type //) Metal Hinged Enclosure for Bulletins and E (Without Transformer) (-/) (-/) (-/) () (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) () () () (-/) IP (Type //) Metal Hinged Enclosure for Bulletins and E (With Transformer) (-/) (-/) () () (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) () () (-/) (-/) (-/) (-/) (-/) (/) (-/) (-/) (/) (/) (/) (/) (/) Publication A-CAA-EN-P -

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

IEC Starter Approximate Dimensions

IEC Starter Approximate Dimensions Technical Data IEC Starter Approximate Dimensions Bulletin Numbers 103H/107H/140M, 103-C/107/C, 105, 109, 106, 112, 113, 190E/191E, 190S/191S, 103S/107S, 103T/107T Topic Page Enclosed Starters and Motor

More information

[V] Common Control Transformer Control (See page 1-78 Note)

[V] Common Control Transformer Control (See page 1-78 Note) Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state

More information

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

Control and Load Switch Specifications Bulletin Number 194E, 194L

Control and Load Switch Specifications Bulletin Number 194E, 194L Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

The Complete Range up to 710 kw. Overview Contactors

The Complete Range up to 710 kw. Overview Contactors The Complete Range up to 710 kw Overview Contactors Rockwell Automation Contactors - the Complet Motor rating AC-3, 400 V 2.2 kw 4.0 kw 5.5 kw 4 kw 5.5 kw 7 Rated operational current 60 C AC-3, 400 V [A]

More information

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types Across the line starters & enclosed A9 AF750 Across the line Description A9 AF750 Maximum UL horsepower ratings UL508A Panel Program, #E105450 NEMA s (00 7) available Compact space-saving design Standard

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

KT4 Manual Motor Starters

KT4 Manual Motor Starters s General Description...F99 Quick Selection Guide...F100 Accessories...F101 Contact Blocks...F101 Adapter Plates...F101 Release Modules...F102 Connecting Modules...F102 Mounting...F103 Enclosures...F103

More information

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings

More information

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊ Series U/CSA Fused Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J Fuses ➋ 30

More information

Technical Information

Technical Information Technical nformation - Second Generation Solid State Overload Relays Technical nformation -ED1... -EE... -EE...D Rated nsulation Voltage - U [V] 69 C Rated nsulation Strength- U imp [kv] 6 C Rated Operation

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

152H F480 F BD B 59 8B

152H F480 F BD B 59 8B ulletin Catalog Number Explanation Open and Non-Combination F F D L a ulletin Number Solid-State Controller F F F F F F F F F F F F F F F F Combination H H F F F F F F F F F F F F F F Enclosed Solid-State

More information

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress

More information

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A WELCOME TO THE WORLD OF COMPLETE AUTOMATION Innovative MCS Starter Solutions MCS Starters and the New Mounting System 141A Welcome to the Wide World of Allen-Bradley Starters Innovative solutions for state

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control . 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10 27Overload Relays Overview Combinations of overload relays and contactors SIRIUS 3R 27Overload Relays Contactors Current range A 3RT10 1 Size S00 3/4/5.5 kw 3RT10 2 Size S0 5.5/7.5/11 kw 3RT10 3 Size S2

More information

Big performance in a small package

Big performance in a small package Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications

More information

Bulletin 505 Full Voltage Reversing

Bulletin 505 Full Voltage Reversing Bulletin 505 Full Voltage Reversing Contactor Accessories Bulletin 500DC Electronic DC Coil Controller Compact size NEMA sizes 0 3 Versatility Fully assembled unit or as a retro fit kit Features LED status

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,

More information

IEC Contactor Specifications

IEC Contactor Specifications Technical Data IEC Contactor Specifications Bulletin Numbers 00/04-K, 00/04-C, 00/04S-C, 00/04-E, 00S-E, 00/04-D, 00S-D, 00-G, 00Q-C Topic Page Product Line Overview IEC Contactors Safety Contactors 4

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

3.1. NEMA Manual Starters.   Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters... Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp

More information

Panelboards & Motor Starters

Panelboards & Motor Starters Appleton s ATX series of Increased Safety distribution panels are available in IP66-rated fiberglass reinforced polyester (FRP) or 316L stainless steel and come in multiple sizes depending on the number

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker

More information

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A) Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

NEMA Space Saving Contactors and Starters

NEMA Space Saving Contactors and Starters Technical Data NEMA Space Saving Contactors and Starters Bulletin Numbers 300, 300S, 305, 309 Topic Page Summary of Changes 1 Product Description 2 Product Selection 3 Accessories (NEMA Sizes 0 3) 7 Accessories

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Motor Protection OLR. CEP7 Second Generation Solid State Overload Relays... B2 Technical Information... B8

Motor Protection OLR. CEP7 Second Generation Solid State Overload Relays... B2 Technical Information... B8 Second Generation Solid State Overload Relays... 2 Technical Information... 8 CT7 Thermal Overload Relays... 17 Technical Information... 20 CT7K & CT4 Thermal Overload Relays... 25 Technical Information...

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

Overload Relays. Overload Relays. CEP9 Electronic Overload Relays... B27 Technical Information & Dimensions (Online)... B34

Overload Relays. Overload Relays. CEP9 Electronic Overload Relays... B27 Technical Information & Dimensions (Online)... B34 Overload Relays CEP7 Solid State Overload Relays... 2 Manual & Automatic Reset... 5 Larger Amp Manual & Automatic Reset... 7 Accessories... 8 Technical Information & Dimensions (Online)... 12 CEP9 Electronic

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE

MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE DOL-Starter Overload Protection PROTECTION FOR AC AND DC MOTORS The Bulletin 193-K

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

825-P Modular Protection System for motors Specification Guide

825-P Modular Protection System for motors Specification Guide Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been

More information

800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.

800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position. 2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: A jumbo or large legend plate is recommended, if space allows. 2-Position Push-Pull Cat. No. 800T-F6D4 2-Position Metal Push-Pull

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors 04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,

More information

CENTERLINE 2500 Low Voltage Motor Control Centers and Power Distribution Gear Catalog Structure Breakdown

CENTERLINE 2500 Low Voltage Motor Control Centers and Power Distribution Gear Catalog Structure Breakdown Technical ata CENTERLINE 2500 Low Voltage Motor Control Centers and Power istribution Gear Catalog Structure Breakdown Catalog Numbers 2500 Table of Contents Topic Page Additional Resources 2 Ordering

More information

STC Starting Torque Controller A Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3

STC Starting Torque Controller A Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3 7 Bulletin 150 Reduced Voltage Starters Section Overview STC Starting Torque Controller 11 22 Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3 SMC-2 Smart Motor

More information

V AC, 50/60 Hz 150-F251NCD 150-F251FCD 24V AC/DC 150-F5NCR

V AC, 50/60 Hz 150-F251NCD 150-F251FCD 24V AC/DC 150-F5NCR Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, Type /) Controllers For use with Line-Connected Motors, Continued Enclosures other than those listed are available; consult your local

More information

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Motor Starter Protectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Overview Enclosures For stand-alone installation of 3RV20

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Page 1 of 9 Knowledgebase Technote ID # Q /24/2006

Page 1 of 9 Knowledgebase Technote ID # Q /24/2006 Page 1 of 9 Knowledgebase Technote ID # Q18356 3/24/2006 Bulletin 520F/520G Multi-Speed NEMA Starters with Eutectic Alloy or Solid-State Overload Relays Sizes 0 through 4 (all series), Size 5 (series L)

More information

Hazardous Factory Sealed Control Devices

Hazardous Factory Sealed Control Devices Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot

More information

Magnetic Overload Relays

Magnetic Overload Relays Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.

More information

Hp V AC Current Rating [A] 230V AC 60 Hz

Hp V AC Current Rating [A] 230V AC 60 Hz Product Selection/Options Open Type Controllers Up to V AC kw Hp V AC Current Rating [A] V AC Hz V AC Hz V AC Hz V AC Hz V AC Hz / Hz Control V AC/DC Control.. -BNBD -BNBR. -BNBD -BNBR -BNBD -BNBR -BNBD

More information