The Complete Range up to 710 kw. Overview Contactors
|
|
- Susanna Kelly Phillips
- 5 years ago
- Views:
Transcription
1 The Complete Range up to 710 kw Overview Contactors
2 Rockwell Automation Contactors - the Complet Motor rating AC-3, 400 V 2.2 kw 4.0 kw 5.5 kw 4 kw 5.5 kw 7 Rated operational current 60 C AC-3, 400 V [A] AC-3, 500 V [A] AC-3, 690 V [A] Rated operational current 40 C AC-1, 400 V [A] Short-circuit protection of contactors 400 V with Circuit Breaker Coordination Type (1)/2 [A] 140M-C2E-B63 (140M-C2E-C10) (140M-C2E-C16) 140M-C2E-C10 140M-C2E-C16 1 Back-up fuse gg (IEC ) 400 V; Coord. Type 1/2 [A] 25/16 25/16 25/16 50/25 50/ M Catalogue Number 100-M05N! 100-M09N! 100-M12N! 100-C09! 100-C12! 1 Cat. No. Suffix Cat. No. Suffix Bulletin 100-M Cat. No. Suffix Bulletin 100-C Coil connection position Blank Line-side coil connectio Enter suffix in Cat. No. U Load-side coil connecti Control Voltage [V] [V] AC Control 50 Hz - D - - KK -50/60 HZ KJ KD KF K Enter suffix in Cat. No. 60 Hz --D - - KK 50/60Hz KD - - KF - - Control Voltage [V] [V] 2 DC Control DC Z24 Z11 DC Z Enter suffix in Cat. No. With diode protection circuit DC ZD24 -With diode protection circuit DC D! Built-in Auxiliary Contacts Enter suffix in Cat. No.! Code 3 = 1 0! Code 10 = = = 0 1 Package Quantity Blank Multi-packing (10 pieces) Blank Unit packing, standar Enter suffix in Cat. No. S Unit packing, standard delivery M Multi-packing (20 pie Circuit Breakers [A] Fuseless protection with Circuit Breakers 0.1 A Cat. No. 140M-C2E-A16 140M-C2E-A25 140M-C2E-A40 140M-C2E-A63 140M-C2E-B10 1 Motor Protection 0.1 A Bulletin 193-EA with Trip Classes 10, 20, 30 Protection with Electronic Overload 0.1 A Bulletin 193-EB with selectable Trip Classes 10, 20, 30; Jam/Stall- and Ground Fault Tripping Relays and Electronic Control and 1.0 A Bulletin 193-EC with adjustable Trip Classes 5 30; DeviceNet Ready; Protection-, Warning-, and Diagn Protection Devices 0.5 A Bulletin CEFB1 with selectable Trip Classes ; Protection Functions: Thermal Overload, Phase Lo 0.5 A Bulletin 825 with adjustable Tripping Classes ; Communication Interface with DeviceNet; Pro Accessories for Contactors Auxiliary Contacts for Bulletin 100-M Auxiliary Contacts for Bulletin 100-C Front mounting Cat. No. Front mounting C MB MB MA MB MA
3 te Range up to 710 kw 7.5 kw 11 kw 15 kw 18.5 kw 22 kw 30 kw 37 kw 45 kw M-C2E-C16 140M-D8E-C25 140M-F8E-C32 140M-F8E-C45 140M-F8E-C CMN CMN CMN /35 80/35 100/63 125/80 160/ / / / C 100-C16! 100-C23! 100-C C C C C C85 00 on position (top, standard delivery) ion position (bottom) 400 KN [V] ZJ ZD With diode protection circuit. DC DJ DD DJ -! Code 00 = 0 0 rd delivery eces) Bulletin 140M-C, Size 1, High Break 25 A 40M-C2E-B16 140M-C2E-B25 140M-C2E-B40 140M-C2E-B63 140M-C2E-C10 140M-C2E-C16 140M-C2E-C20 140M-C2E-C A Bulletin 140M-D, Size 2, High Break PLUS 25 A Cat. No. 140M-D8E-B25 140M-D8E-B40 140M-D8E-B63 140M-D8E-C10 140M-D8E-C16 140M-D8E-C20 140M-D8E-C A Bulletin 140M-F, Size 3, High Break Cat. No. 140M-F8E-C10 140M-F8E-C16 140M-F8E-C20 140M-F8E-C25 16 A Cat. No. 140-CMN A 85 A nostic Functions; Integrated I/O s; Underload-, Ground Fault-, and Thermistor Protection 85 A Extension of ra oss, Asymmetry, Thermistor Overtemperature tection-, Warning-, Diagnostic-, and Control Functions; Integrated I/O s; Underload-, Ground Fault-, and Thermistor Protection; PT 100 Temperature Sensors; Start-up Mo Cat. No. Side mounting Cat. No. 00-FA SB FA SB FA SB FA SB FA SB FA 40
4 45 kw 55 kw 75 kw 55 kw 75 kw 90 kw 110 kw 132 kw M-K5F-D10 140M-K5F-D12 140M-K5F-D16 140M-K5F-D12 140M-K5F-D16 140M-M5F-D20 140M-M5F-D25 140M-M5F- 250/ / / / / / / /400 CAB6 CAB6-85-!- CAB6-105-!- CAB6-140-!- CAB6-105-EI-!- CAB6-140-EI-!- CAB6-170-EI-!- CAB6-210-EI-!- CAB Cat. No. Suffix Bulletin CAB6 Electronic Coil Control [V] [V] HZ /60 Hz HZ --- -➀ Only for CAB /60 HZ ➀ and CAB [V] [V] DC DC AC Control DC Control! Code 00 = 0 0! Code L11 = 1 0! Code 00 = = 1 1 L22 = = Aux. Contact used internally A Bulletin 140M-K Cat. No. 140M-K5F-C50 140M-K5F-C63 140M-K5F-C80 140M-K5F-D PLUS 45 A 140M-F8E-C32 140M-F8E-C45 Bulletin 140-CMN 90 A 140-CMN CMN CMN CMN-9000 ange in preparation onitoring Auxiliary Contacts for Bulletin CAB6 Left-side mounting Cat. No. Right-side mounting Cat. No. 1 1 CAB6-P CAB6-P CAB6-P CAB6-P4-11 Electronically compatible Auxiliary Contacts Left-side mounting CAB6-P3-B11 Right-side mounting CAB6-P2-B11
5 160 kw 220 kw 315 kw 400 kw 500 kw 600 kw 710 kw D25 140M-P5F-D32 140M-P5F-D / /500 (630)/-800/- 1000/-1000/-1250/- EI-!- CAB6-300-EI-!- CAB6-420-EI-!- 100-G G G G G Cat. No. Suffix Bulletin 100-G [V] [V] [V] /60Hz /60 Hz KD KF KN 50/60 Hz KD KF KN [V] [V] [V] 110 DC 76 DC KD DC ZD Coil usable for AC and DC Control! Code 22 = 2 2! Code 12 = A D10 140M-K5F-D12 140M-K5F-D A Bulletin 140M-M 250A Cat. No. 140M-M5F-D16 140M-M5F-D20 140M-M5F-D A Bulletin 140M-P 400 A Cat. No. 140M-P5F-D25 140M-P5F-D32 140M-P5F-D A Auxiliary Contacts for Bulletin- 100-G Cat. No. For 100-G G FA22-56 For 100-G1000, 100-G FA11-7 For 100-G1000, 100-G (Late Break) 100-FAL11-7 bis 2000 A
6 Contactors 100-C and CAB6 Greater Performance in Less Space MCS Contactors 100-C Common accessories simplify handling and increase flexibility. All accessories fit to all contactor sizes 100-C. The mechanical interlocks can provide interlocking between the smallest and largest contactor sizes 100-C. Auxiliary contacts may be mounted at the front, to the left or right side. There are still enough contacts available, even when timing modules, mechanical latches or interlocks are used. Modern terminals offer more comfort and save wiring time. Two separate wiring terminals per pole maximize wiring options and termination reliability. Easy fitting of large cross sectional or combinations of conductors. Insertion funnels and embedded terminals guarantee increased finger protection. Screw driver guiding shafts speed up connection time. Delivered with open terminal screws for immediate wiring. Contactors CAB % You save 80 % 0 Conventional Contactor CAB6 with electronic coil control Integrated interface for direct PLC connection Integrated in the coil manager and therefore less space and wiring required. Configurable for conventional or electronic interface control. Coil manager saves energy and protects contactor Up to 5 times less energy consumption. Wider voltage ranges. Distinct on/off thresholds; no contact chatter possible. Contactors CAB6 The contactor line for motor ratings from 45 up to 220 kw. Faster wiring due to advanced termination technology.
7 The MCS Modular Control System sets the standards MCS Starters at your disposal Compact starters with up to date technology for compact controls. MCS offers the highest flexibility in configuring starter assemblies. Which Starter? Starter selection Circuit diagram Layout Assembly test MCS Star the powerful program for motor starters MCS Star simplifies the confuiguring of motor starters. Determines immediately the correct Catalogue Number based on the application parameters. MCS Contactors 100-C The contactor line for motor ratings from 4 up to 45 kw. High personal and functional safety due to the extensive security package. MCS Circuit Breakers 140M The slimline solution for powerful, compact starters with short-circuit- and motor protection. MCS Electronic Overload Relays 193-E State-of-the-art technology for maximum protection, high reliability and performance. Communication Modules DSA Provide the integration of MCS motor starters into the DeviceNet communication network.
8 Complete Automation - Your Connection to Better Solutions Here at Rockwell Automation, we know that the best way to meet your needs is to bring together the best - the best technology, skills and expertise available. That s what we call Complete Automation. Complete Automation stands for Rockwell Automation s commitment to understand our customers needs, both technical and commercial. We are dedicated to responding to those needs by bringing together the best the industry has to offer, from stand-alone products to complete automation solutions. It s a comprehensive approach to automation. A complete approach. And it s only available from Rockwell Automation and our partners. Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, USA, Tel: (1) , Fax: (1) Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI USA, Tel: (1) , Fax: (1) Europe: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36-BP 3A/B, 1170 Brussels, Belgium, Tel: (32) , Fax: (32) Asia Pacific: Rockwell Automation, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) , Fax: (852) Headquarters for Dodge and Reliance Electric Products Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC USA, Tel: (1) , Fax: (1) Europe: Rockwell Automation, Brühlstraße 22, D Elztal-Dallau, Germany, Tel: (49) , Fax: (49) Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore , Tel: (65) , Fax: (65) Publication 100-PP001B-EN-P January Rockwell International Corporation All Rights Reserved Printed in Switzerland
Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control
Selection Guide for SMC-Delta and SMC-3 A New Dimension in Motor Control Discover a New Dimension in Motor Control: SMC-Delta and SMC-3 The Allen-Bradley SMC-Delta and SMC-3 softstarters from Complete
More informationExample Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule.
IRRIGATION TRAINING & RESEARCH CENTER California Polytechnic State University San Luis Obispo, CA 93407-0730 Phone: 805.756.2434 FAX: 805.756.2433 www.itrc.org Example Maintenance Schedule 1 The attached
More informationVARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS
VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS IN 1904, RELIANCE ELECTRIC INTRODUCED THE WORLD'S FIRST VARIABLE SPEED MOTOR. FOR OVER 96 YEARS, RELIANCE ELECTRIC MOTORS HAVE LED THE INDUSTRY
More informationPowerFlex 700 User Manual Update
DANGER REMOTE SOURCE(S) OF POWER. DISCONNECT ALL SOURCES OF POWER BEFORE OPENING THE DOOR. ENERGY STORAGE CAPACITORS. VERIFY LOW VOLTAGE DISCHARGE BEFORE SERVICING. SEE INSTRUCTION MANUAL. Document Update
More informationInstallation, Operation And Maintenance of. AC and DC Mine Motors
Installation, Operation And Maintenance of AC and DC Mine Motors Instruction Manual B-3623-1 June, 2003 Table of Contents General Safety/Acceptance Instructions..2 Installation Instructions. 3 Operating
More informationWorld-Class Motion Control with Worldwide Support
Rockwell Automation is an automation leader who not only develops innovative technology, but has the expertise and global supply network to be your complete automation solution provider. Rockwell Automation
More informationUNIT CONVEYOR SYSTEMS
UNIT CONVEYOR SYSTEMS PRE-ENGINEERED VARIABLE SPEED DRIVE PACKAGES Pre-engineered drive package assemblies combine the strength of Dodge and Reliance products to provide a total variable speed unit conveying
More informationWELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A
WELCOME TO THE WORLD OF COMPLETE AUTOMATION Innovative MCS Starter Solutions MCS Starters and the New Mounting System 141A Welcome to the Wide World of Allen-Bradley Starters Innovative solutions for state
More informationDODGE QUANTIS MAKES THE GLOBAL CONNECTION
DODGE QUANTIS MAKES THE GLOBAL CONNECTION HOLLOW SHAFT SOLID SHAFT DOUBLE ENDED SOLID SHAFT HOLLOW SPLINED SHAFT SHRINK DISK CONNECTION SHAFT RHB FOOTLESS FLANGE RHB FOOT MOUNTED NE SEPARA ARATE C Output
More information841XL PREMIUM EFFICIENCY MOTORS
841XL PREMIUM EFFICIENCY MOTORS 8 4 1 X L A C M O T O R S D E S I G N E D T O M E E T Y O U R S E V E RE D U T Y N E E D S As an original member of the NEMA Energy Task Force, Rockwell Automation has
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More informationBulletin 190E/191E Direct On-Line Eco Starters
Bulletin 190E/191E Direct On-Line Eco Starters Group Motor, Type E and Type F Combination Motor Controllers (UL/CSA) The 190E/191E motor controllers can be used in a variety of applications. These starters
More informationResistive Brake Module
Installation Instructions Resistive Brake Module (Catalog Numbers 2090-XB33-16, 2090-XB33-32, 2090-XB120-01, 2090-XB120-03, and 2090-XB120-06 This publication provides installation instructions for the
More informationBulletin 100-D IEC Contactors
Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact
More informationBulletin 190S/191S Direct On-Line Compact Combination Starters
Bulletin 190S/191S Direct On-Line Compact Combination Starters Group Motor, Type E and Type F Combination Motor Controllers (UL/CSA) The 190S/191S motor controllers can be used in a variety of applications.
More informationAC Drives Regenerative Energy Solutions. Product Summary
AC Drives Regenerative Energy Solutions Product Summary #% &TKXGU Regenerative Energy Solutions Snubber Resistor Braking Kits Line Regeneration Controls Synchronous Rectifier Controls AC Drives and Regenerative
More informationBulletin 190-M Compact Starters. Selection Guide
Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located
More information1370 DC Loop Contactors and Lug Kits
Installation Instructions 1370 DC Loop Contactors and Lug Kits 1370 DC Contactors are electromagnetically held contactors specially designed to switch the armature current from a DC drive module to a shunt
More informationFlexPak 3000 DC Drives and WebPak 3000 DC Drives Replacement Parts
FlexPak 000 DC s and WebPak 000 DC s Replacement Parts Instruction Manual D-48-5 Effective Date: March, 007! ATTENTION: Only qualified electrical personnel familiar with the construction of this equipment
More informationSwitchgear for Railway Applications
Selection Guide Contactors Contactor Relays Motor Protection Circuit Breakers Circuit Breakers Bimetallic Overload Relays Electric Switchgear for Rolling Stock Application What s Inside Topic Page Topic
More informationPowerFlex DC Drive - Frame C Field SCR Module
Installation Instructions PowerFlex DC Drive - Frame C Field SCR Module!!! ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the installation,
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationIEC Contactor Specifications
Technical Data IEC Contactor Specifications Bulletin Numbers 00/04-K, 00/04-C, 00/04S-C, 00/04-E, 00S-E, 00/04-D, 00S-D, 00-G, 00Q-C Topic Page Product Line Overview IEC Contactors Safety Contactors 4
More informationIndustry Automation Control Components
Industry Automation Control Components SIRIUS 3RV2 Motor Starter Protectors SIRIUS 3RV21 Motor Starter Protectors can be easily and flexibly combined with other SIRIUS devices to reduce space requirements
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationStars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON
Only for internal use Stars or starlets? Competitor overview switching devices sirius IN COMPARISON Who are the real stars? The comparison. Under ideal conditions, the human eye can make-out approximately
More informationMCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE
MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE DOL-Starter Overload Protection PROTECTION FOR AC AND DC MOTORS The Bulletin 193-K
More informationPRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V
PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable
More informationABB s new control and protection devices
ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationLOW VOLTAGE SWITCHGEAR
LOW VOLTAGE SWITCHGEAR S-N Motor Control Mitsubishi Electric s S-N Series contactors are perfect for the control of 3 phase power, either for the direct control of a motor, to supply power to a drive or
More informationBulletin 193-T1 Bimetallic Overload Relays
Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode
More informationCircuit-Breakers Bulletin 140 / KTA 3
Motor Protection Characteristics High Switching Capacity High Current Limiting For Compact Motor Starters Overview... - Product Selection -Pole... - 4-Pole... -7 Accessories... -8 Type: Bulletin 40-MN
More informationPalletiser Functional Safety Specification
Palletiser Functional Specification R Non-muted Light Curtain (generally in-feed conveyor), pages 6...7 +V DC * L-PSxxxxYD Power/ Fault Reset 800F-F6 800F-AL Auto Signal To PLC Start/Restart 800F-F8 800F-AL
More informationIEC Starter Approximate Dimensions
Technical Data IEC Starter Approximate Dimensions Bulletin Numbers 103H/107H/140M, 103-C/107/C, 105, 109, 106, 112, 113, 190E/191E, 190S/191S, 103S/107S, 103T/107T Topic Page Enclosed Starters and Motor
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More information825-P Modular Protection System for motors Specification Guide
Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection
More informationBulletin 140M Motor Protectors
0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationNEMA Space Saving Contactors and Starters
Technical Data NEMA Space Saving Contactors and Starters Bulletin Numbers 300, 300S, 305, 309 Topic Page Summary of Changes 1 Product Description 2 Product Selection 3 Accessories (NEMA Sizes 0 3) 7 Accessories
More informationIT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus
IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus Control and Expanded Functionality for Intelligent Technologies (IT.) See How IT. All Works Together A Complete Family of IEC
More informationXT IEC Power Control Manual Motor Protectors
May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted
More informationIEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101
IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With
More informationOverview. Contents. Overview
1/0 Overview 1 Contents Overview 3-pole Block Contactors and Motor Protection... 1/ 4-pole Block Contactors... 1/3 Contactors for Specific Applications... 1/4 Mini Contactors and Motor Protection... 1/
More informationMedium Voltage Contactor
Medium Voltage Contactor (Series D) Bulletin 1502 400A 2400 to 7200 volts User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
More informationUS Catalog. Motor protection and control AF Range contactors & overload relays
US Catalog Motor protection and control AF Range contactors & overload relays Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors (500
More informationLifting & Mounting PowerFlex 700S and 700H Drives (Frames 10-14)
Installation Instructions Lifting & Mounting PowerFlex 700S and 700H s (Frames 10-14) General Precautions! TTENTION: To guard against possible personal injury and/or equipment damage Do Not allow any part
More informationSIRIUS Configuration
SRUS Configuration Selection data for Fuseless Load Feeders Brochure January 2008 www.siemens.com/automation SRUS the Modular System Family for the Switching, rotecting and Starting of s n order to simplify
More information3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,
Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,
More informationBulletin 100-C Contactors. Bulletin 193-E Solid-State Overload Relays. Bulletin 193-T Bimetallic Overload Relays
MCS Starter Components Section Overview Bulletin 100-C Contactors 9 85A (4 45kW/5 60 HP) AC and DC versions Page 3 Bulletin 193-E Solid-State Overload Relays 0.1 85A Page 30 Bulletin 193-T Bimetallic Overload
More informationStandard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes
More informationSIRIUS 3RU2 Thermal Overload Relays
Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to
More informationDEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationPowerFlex DC Drive - Frame A Pulse Transformer Circuit Board
Installation Instructions PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the
More informationExternal Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx
External us Resistor Kit for LiquiFlo Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx Instruction Manual D2-3538!!!!! TTENTION: Only qualified electrical personnel familiar with the
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationInnovation in actuation.
Innovation in actuation. Keystone EPI-2 Quarter Turn Electric Actuators Control your low-torque quarter turn valves and dampers more effectively, even in the largest plants. A world of experience Keystone
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationFor Operation in the Control Cabinet 3RW Soft Starters
General Data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationSelf-protected Combination Starters System PKZ 2-SP
Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller
More informationMotor Protection Circuit Breaker and Motor Circuit Protector Specifications
Technical Data Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Bulletin Number 140M Topic Page Bulletin 140M Motor Protection Circuit Breakers 3 Overview 3 Catalog Number Explanation
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationNumber 1 in efficiency
PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The new device category! The PowerXL DE1 Variable Speed Starter The PowerXL DE1 Variable Speed Starter one device, all the advantages
More informationPRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES
PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES Rockwell Automation expands its new line of Allen-Bradley Bulletin 1494C Cable-Operated, -Mounted Switches that meet industrial
More informationMotor Protection Circuit Breakers
Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-ASB Series B) 1 9 2 3 4, 5 6 7 8 Component Identification 1 Remote I/O Adapter module 2 Indicators 3 Communication reset pushbutton (PRL) 4 Access door to switches
More informationLow voltage switch gear
Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling
More informationAF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated
AF09... AF3 3-pole contactors 4 to 1.5 kw, AC / DC operated AF09-30-10 AF09... AF3 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors
More informationReliably Switching Highest Currents up to 2000 A
www.moeller.net Reliably Switching Highest Currents up to 2000 A The complete range for the motor circuit. From contactors to efficient motor-starters to controlled drives. New solutions that rely on communication.
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationShort form catalogue. Motor protection & control
Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59
More informationIndustrial Controls. Load Feeder. Configuring SIRIUS Innovations Selection data for Fuseless and Fused Load Feeders. Configuration Manual 04/2011
Load Feeder Selection data for Fuseless and Fused Load Feeders Configuration Manual 04/2011 Industrial Controls Answers for industry. Introduction 1 General information 2 Industrial switchgear Load feeders
More informationSwitches Unlimited Phone: * Fax:
For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings
More informationShort form catalogue Motor protection and control Block contactors and overload relays
Short form catalogue Motor protection and control Block contactors and overload relays Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors
More informationBulletin 509 Three Phase Full Voltage NEMA Starters Size 00 (all series) Renewal Parts
Page 1 of 7 Knowledgebase Technote ID # Q18318 3/28/2006 Renewal Parts The 509 Three phase starter consists of three switching poles, a fourth pole to be used as a control circuit hold-in contact and overload
More informationQuick selection table
Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More informationProtection Equipment
Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection
More informationLR9 F OVERLOAD RELAYS
Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.
More information3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008
Siemens AG 2008 General data The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations
More informationThe motor starter on the power bus. Solutions for conveyor technology. Full speed ahead
The motor starter on the power bus Solutions for conveyor technology The motor starter on the power bus Full speed ahead The system solution The motor starter on the power bus The motor starter The podis
More informationCertifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE
Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused
More informationTechnical Information
Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationABB Softstarter Benefits Charnchanok Thongprad
ABB Softstarter Benefits Charnchanok Thongprad tomation Technology Products AB Control - 1 - - Why Softstarters? Benefits for the Electrical network Reduces voltage drops on networks Minimizes starting
More informationIEC Load Switches Bulletin 194E 25 Amps to 100 Amps
Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,
More information3VU13, 3VU16 Circuit-Breakers
3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used
More informationSeries CA6 Contactors
Series CA6 Contactors The modern contactor for demanding applications from 75 to 600HP (@460V) - 00 to 700HP (@ 575V) Sprecher + Schuh s CA6 contactor line combines the simple function of our popular CA7
More informationDRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...
100HP 400HP 700HP 1000HP 1400HP PCS Softstarter Controller IN-rail mountable microprocessor controller for 3-phase motors up to 480A (3...85A din-rail mountable) Provides three different starting modes
More information3VF3 to 3VF8 Circuit-Breakers
3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating
More informationMotor Protection Circuit Breaker and Motor Circuit Protector Specifications
Technical Data Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Bulletin 140M Topic Page Topic Page Bulletin 140M Motor Protection Circuit Breakers 3 Accessories 17 Overview
More informationControl Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control
More informationCapacitor Switching Contactors Type K3...-A, K3...-K
Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and
More informationAbout us. Switchgear Factory, Mumbai
About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationManual motor starters Overview and benefits
Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection
More informationAE 9... AE 40 Contactors NE... Contactor Relays
Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal
More information