2 Port Solenoid Valve/Air Operated Valve For Dust Collector

Size: px
Start display at page:

Download "2 Port Solenoid Valve/Air Operated Valve For Dust Collector"

Transcription

1 2 Port olenoid Valve/ir Operated Valve or ust ollector eries /VX2 Large port size is available. 50 to 00 added lange type Mounting can be changed depending on the piping conditions. Piping lange type, lange body type added Power consumption 4.5 W xcluding size 23 nclosure P65 lectrical entry aston type terminal is P40. lange body type Orifice machining on the outlet is not necessary, so piping man hour is reduced! [xcluding VX] o aston terminal type added VX VX VX VX3 VX lange body type (Through hole mounting type) nstallation xample lange body type (lange mounting type) lange body type irect piping type lange type olenoid valve type ir operated type Variations ontroller dedicated for operation eries VX Type irect piping type lange type Piping lange body type lange mounting type lange body type Through hole mounting type lectrical entry olenoid valve type only olenoid valve type ir operated type N terminal onduit terminal onduit aston terminal 267

2 2 Port olenoid Valve/ir Operated Valve or ust ollector eries /VX2 nclosure P65 Low-noise construction Metal noise reduced by the rubber bumper ilencer (Option) Power consumption 4.5 W (ize 2, 22, 24, 25, 26, 27, 28) 8 W(ize 23) mproved armature durability lame resistant L94V-0 conformed Piping variations 20, 25, 40 50, 65, 80 New 90, 00 uilt-in full-wave rectifier type ( specification) mproved durability ervice life is extended by the special construction. (compared with current shading coil) educed apparent power V 7 V (ize 2, 22, 24, 25, 26, 27, 28) 8 V 0 V (ize 23) Noise reduction ectified to by the full-wave rectifier, resulting in a buzz noise reduction. Low-noise construction pecially constructed to reduce the metal noise during operation. olenoid Valve Type eries ir Operated Type eries VX2 268

3 ontroller edicated or Operation/eries VX Page 0 The valve controller turns ON/O many valves for the dust controller. Power supply voltage Number of output points 00 V to 220 V 24 V, 2 V 6 output points, 0 output points pplication example low tube Nozzle 2 port solenoid valve for dust collector () lean air outlet ag filter ontroller dedicated for operation (VX) VX VX ust including air inlet VX ust exhaust port VX3 VX Two-time itting unction two-time hitting function is adopted to improve the bag filter dusting efficiency. Turn ON the P switch for two-time hitting (O for one-time hitting). (ffective up to the number of setting channels) Operation sequence diagram 4 output points Two-time hitting only for 2 or ON for sec. O for 2 sec. Power supply ON time 2 sec. sec. sec. 2 sec. 2 sec. 2 sec. 2 sec. sec. sec. sec. sec. 2 sec. Two-time hitting sec. 2 sec. sec. nterrupt Operation unction nterrupting an operation from an external switch is possible using input signals. Operation sequence diagram top signal ONt Ot Ot t Ot t Power switch ON (Output start) Power switch O (Output stop) ascade onnection (Multiple-board connection) VX0: One board allows outputs at merely 0 output points max. ut the points can be increased to 20 and output points by connecting cascades. onnection ontroller No. (Master) lave setting ontroller No.2 (lave) lave setting ontroller No.3 (lave) lave setting ontroller No.n (lave) lave setting Operation sequence diagram No. output No.2 output No.3 output No.n output cycle tart Operation No. No.2 output output No.3 output No.n output No. output No.2 output 269

4 eries olenoid Valve Type ommon pecifications/election teps pecifications olenoid Valve Type Orifice size luid mmø Minimum operating pressure MPa Maximum operating pressure MPa luid temperature mbient temperature oil insulation type nclosure Part no. llowable voltage fluctuation V Power consumption V W olenoid oil pecifications ir (No freezing) to 60 5 to 60 lass P65 ±0% of rated voltage Normally losed (N..) pecification ize Power consumption (W) Note ) Temperature rise ( ) Note 2) ize 2,22,24,25,26,27, ize Note ) Power consumption, pparent power: The value at ambient temperature of 20 and when the rated voltage is applied. (Variation: ±0%) Note 2) Value at ambient temperature of 20 and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. pecification (uilt-in ull-wave ectifier Type) ize ize 2,22,24,25,26,27,28 ize 23 pparent power (V) Note ) Note 2) Temperature rise ( ) Note 3) Note ) Power consumption, pparent power: The value at ambient temperature of 20 and when the rated voltage is applied. (Variation: ±0%) Note 2) There is no difference in the frequency and the inrush and energized apparent power because a rectifying circuit is used in the (uilt-in full-wave rectifier type). Note 3) Value at ambient temperature of 20 and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. election teps tep elect the port size. tem election item 20 (3/4) 25 () 40 ( /2) 50 (2) 65 (2 /2) 80 (3) 90 (2 /2) 00 (4) ymbol q q tep 2 tep 3 tep 4 tep 5 elect the piping system. tem Piping tem Material With/without silencer election item irect piping type lange type lange body type lange body type election item N/POM Without silencer N/POM With silencer ymbol iaphragm/main valve material, elect whether the silencer is mounted. elect electrical specification. tem lectrical specification Voltage/lectrical entry 24 V or other special options, refer to page 274. ymbol ymbol w e r w e r 270

5 2 Port olenoid Valve or ust ollector eries ow to Order o ymbol Port size olenoid Valve Type ymbol Piping Piping irect piping type irect piping type lange type irect piping type lange type lange body type lange body type lange type Material With/without silencer ymbol iaphragm/ With/without Main valve material silencer N/POM N/POM Without With : irect piping type : lange type Voltage lectrical entry ymbol L M N P T V W ommon pecifications iaphragm/main valve material N/POM oil insulation type lass Voltage 24 V lectrical entry 00 V 0 V with surge 200 V voltage suppressor 2 V 24 V 24 V N terminal 00 V with surge 0 V voltage suppressor 200 V 2 V 24 V onduit 00 V terminal 0 V with surge voltage 200 V suppressor 2 V 24 V onduit 00 V with surge 0 V voltage suppressor 200 V 2 V aston terminal VX VX VX VX3 VX Y 24 V Z Other voltages : lange body type (lange mounting type) : lange body type (Through hole mounting type) or other special options, refer to page V 48 V pecial voltage 220 V 240 V 2 V N terminal with light With conduit terminal and light thread NPT thread 27

6 eries VX2 ir Operated Type ommon pecifications/election teps pecifications ir Operated Type Part no. Orifice size mmø luid Minimum operating pressure MPa Maximum operating pressure MPa luid temperature mbient temperature VX2 VX22 VX23 VX ir VX25(,) (No freezing) to 60 5 to 60 VX26(,,,) 0. VX27 VX election teps tep elect the port size. tem election item 20 (3/4) 25 () 40 ( /2) 50 (2) 65 (2 /2) 80 (3) 90 (2 /2) 00 (4) ymbol q q VX2 tep 2 tep 3 elect the piping system. tem Piping tem Material With/without silencer election item irect piping type lange type lange body type lange body type election item N/POM Without silencer N/POM With silencer ymbol iaphragm/main valve material, elect whether the silencer is mounted. ymbol w e w VX2 e VX2 tep 4 or other special options, refer to page

7 2 Port ir Operated Valve or ust ollector eries VX2 ow to Order o ir Operated Type VX2 ommon pecifications iaphragm/main valve material N/POM Piping Material With/without silencer ymbol Port size ymbol Piping ymbol iaphragm/ Main valve material With/without silencer irect piping type N/POM N/POM Without With or 40 or less, silencer cannot be selected. VX VX irect piping type lange type irect piping type lange type lange body type lange body type lange type or other special options, refer to page 274. thread NPT thread VX VX3 aution VX election of Pilot Valve When selecting the air operated type VX2 series, select the 2 port valve with the stated orifice diameter or more. VX2 to VX23: ø5 mm or more VX24 to VX28: ø4 mm or more : irect piping type : lange type : lange body type (lange mounting type) : lange body type (Through hole mounting type) 273

8 eries /VX2 Other pecial Options lectrical Option (pecial voltage, with light) Z nter standard product number. lectrical option pecial voltage lectrical entry/lectrical option 274 pecifications pecial voltage With light Without N connector ymbol V L M W N P Y T V 2 2 2L 2M 2N 2P W 2T V 3 Voltage 48 V 220 V 240 V 24 V 2 V 2 V 48 V 220 V 240 V 24 V 2 V 48 V 220 V 240 V 24 V 2 V 48 V 220 V 240 V 24 V 2 V 2 V 24 V 00 V 0 V 200 V 2 V 48 V 220 V 240 V 24 V 2 V 24 V 00 V 0 V 200 V 2 V 48 V 220 V 240 V 24 V 2 V 24 V 00 V 0 V 200 V 2 V 48 V 220 V 240 V 24 V 2 V lectrical entry (with surge voltage suppressor) (with surge voltage suppressor) N terminal (with surge voltage suppressor) onduit terminal (with surge voltage suppressor) onduit (with surge voltage suppressor) aston terminal N terminal (with surge voltage suppressor) onduit terminal (with surge voltage suppressor) N terminal (with surge voltage suppressor) Other Option (Port thread) VX()2 nter standard product number. Piping option Port thread ymbol Port thread NPT nter symbols in the order below when ordering an electrical option and other option. xample) olenoid valve type Z lectrical option Other option

9 eries /VX2 Valve haracteristics The valve characteristics data was measured with the outlet piping length. The valve characteristics vary depending on the tank capacity, air supply, set pressure, outlet conditions (nozzle size, quantity, piping length), so please use these values as a guideline.. esponse Time, tart-up peed Type Measuring conditions Test circuit efer to the circuit below. Test sample ( 3/4) 2 ( ) 3 ( /2) 4 ( 2) 5, ( 2 /2) 6,,, ( 3) 7 ( 3 /2) 8 ( 4) ir tank capacity to 2: 00 L 3 to 4: 200 L 5 to 8: 000 L nergizing time 50 msec ated voltage 24 V Outlet piping length 500 mm Thread size connected to the outlet piping end : c3/8 2: c/2 3: c3/4 4: c 5: c /2 6: c2 7: c2 /2 8: c3 ow to calculate. et the tank pressure to 0.5 MPa. 2. lose the stop valve on the inlet of the tank. 3. nergize the valve and read the pressure wave on the outlet. ir tank Vl ontroller (VX06) Piping length Oscilloscope istortion gauge estrictor VX2 Type Measuring conditions Test circuit efer to the circuit below. Test sample VX2 ( 3/4) VX22 ( ) VX23 ( /2) VX24 ( 2) VX25, ( 2 /2) VX26,,, ( 3) VX27 ( 3 /2) VX28 ( 4) ir tank capacity VX2 to VX22: 00 L VX VX23 to VX24: 200 L VX25 to VX28: 000 L VX nergizing time 50 msec Pilot valve 32 (Orifice, ø5, ated voltage 24 V) Piping length to the pilot valve 500 mm, 000 mm, 500 mm (ø0, t =.5) VX Outlet piping length 500 mm Thread size connected to the outlet piping end VX2: c3/8 VX22: c/2 VX23: c3/4 VX24: c VX25: c /2VX26: c2 VX3 VX27: c2 /2 VX28: c3 ow to calculate VX. et the tank pressure to 0.5 MPa. 2. lose the stop valve on the inlet of the tank. 3. nergize the pilot valve and read the pressure wave on the outlet. ir tank Vl VX2 istortion gauge Piping length Piping length to pilot valve estrictor Oscilloscope ontroller (VX06) Pilot valve (32) Test circuit VX2 Test circuit ON response time Time required until the valve is switched after it is energized (Time required until pressure is released to the outlet) tart-up speed peed until the valve is switched after being energized and the pressure released to the outlet reaches 90% of the peak pressure tart-up speed = (Pm x 0.9)/ t [MPa/msec] Voltage waveform Pressure waveform in the tank ow to ead the ata 50 msec Note) or air operated type, the longer the piping length to the pilot valve, the longer the ON response time will be. f the piping length is extended more, the valve might not be opened due to piping capacity and resistance in the piping, so keep the piping length to the pilot valve as short as possible. Outlet pressure waveform Pm (Peak pressure) Pm x 90% ON response time 0% t 275

10 eries /VX2. esponse Time, tart-up peed /or solenoid valve type, the piping length to the pilot valve should be 0 mm. ON esponse Time 00 tart-up peed ON response time (msec) VX22 VX2 tart-up speed (MPa/msec) VX23 VX2 VX Piping length to the pilot valve (mm) Piping length to the pilot valve (mm) ON response time (msec) 80 VX25, 70 VX VX24 tart-up speed (MPa/msec) VX25, VX Piping length to the pilot valve (mm) Piping length to the pilot valve (mm) ON response time (msec) VX28 VX26 VX27 tart-up speed (MPa/msec) VX26 VX27 VX Piping length to the pilot valve (mm) Piping length to the pilot valve (mm) 276

11 Valve haracteristics eries /VX2 2. ischarge Volume /or solenoid valve type, the piping length to the pilot valve should be 0 mm. Type Measuring conditions Test circuit efer to the circuit below. Test sample ( 3/4) 2 ( ) 3 ( /2) 4 ( 2) 5, ( 2 /2) 6,,, ( 3) 7 ( 3 /2) 8 ( 4) ir tank capacity to 2: 00 L 3 to 4: 200 L 5 to 8: 000 L nergizing time 50 msec ated voltage 24 V Outlet piping length 500 mm Thread size connected to the outlet piping end Open ow to calculate. et the tank pressure to 0.5 MPa. 2. lose the stop valve on the inlet of the tank. 3. nergize the valve and read the tank pressure after releasing the pressure. ir tank Vl ontroller (VX06) Piping length Test circuit VX2 Type Measuring conditions Test circuit efer to the circuit below. Test sample VX2 ( 3/4) VX22 ( ) VX23 ( /2) VX24 ( 2) VX25, ( 2 /2) VX26,,, ( 3) VX27 ( 3 /2) VX28 ( 4) ir tank capacity VX2 to VX22: 00 L VX23 to VX24: 200 L VX25 to VX28: 000 L nergizing time 50 msec Pilot valve 32 (Orifice, ø5, ated voltage 24 V) Piping length to the pilot valve 500 mm, 000 mm, 500 mm (ø0, t =.5) Outlet piping length 500 mm Thread size connected to the outlet piping end Open ow to calculate. et the tank pressure to 0.5 MPa. 2. lose the stop valve on the inlet of the tank. 3. nergize the pilot valve and read the pressure wave on the outlet. ir tank Vl VX2 Piping length ontroller (VX06) Pilot valve (32) VX VX VX VX3 VX ischarge volume: Valve discharge volume per energizing time onversion of the discharge volume alculate the discharge volume by reading the tank pressure after the valve starts the operation. onversion equation V0 = (P x V P2 x V)/P0 V0: ischarge volume L P: Tank initial pressure MPa (bsolute pressure) V: Tank capacity L P2: Tank pressure after release MPa (bsolute pressure) P0: tmospheric pressure MPa (bsolute pressure) Piping length VX2 Test circuit Note ) f the regulator or the restrictor is installed right before the N side of the valve, the valve may oscillate when it is turned off. eep the regulator or the restrictor away from the valve for at least m or change restriction. Note 2) The dust collector valve is a large flow control valve in which air is discharged with high speed to clean the bag filter with impact wave. Tank capacity should be sufficient to secure impact wave and discharge flow rate. f the air tank capacity is insufficient, response delay of valve, malfunctions or oscillation may occur. ischarge Volume ischarge volume (L) VX()22 VX()23 VX() Piping length to the pilot valve (mm) ischarge volume (L) VX()25, VX() Piping length to the pilot valve (mm) ischarge volume (L) VX()27 VX()26 VX() Piping length to the pilot valve (mm) 277

12 eries /VX2 onstruction olenoid Valve Type 2 /irect piping type 3 ir Operated Type VX2 2 /irect piping type 3 t r w e r w e q q 4 5 /irect piping type 6 4 VX2 5 /irect piping type 6 t y r w e q t r w e q omponent Parts No. escription Material ody onnet iaphragm assembly pset bolt Pilot valve assembly iaphragm assembly for pilot valve N, POM, tainless steel N, POM omponent Parts No. escription Material ody onnet iaphragm assembly pset bolt iaphragm assembly for pilot valve N, POM, tainless steel N, POM eplacement Parts VX()2() VX()22() VX()23() VX()24() VX()25() VX()26() olenoid valve type VX-2 VX-22 VX-23 VX-24 VX-25 VX-26 ir operated type VX-2 VX-22 VX-23 VX-24 VX-25 VX-26 Note) pring is shipped together with the product, but not assembled. 278 iaphragm assembly Note) iaphragm assembly for pilot valve ilencer olenoid valve type ir operated type olenoid valve type N20-02 N20-02 N20-02 N20-02 N40-04 N40-04 ir operated type N20-02 N40-04 N40-04

13 2 Port olenoid Valve/ir Operated Valve or ust ollector eries /VX2 onstruction olenoid Valve Type /lange type 8 t y ir Operated Type 5 6 VX2 7 /lange type 8 t 6 /lange body type r w e VX26 /lange body type r w e VX VX t y t VX w r e q w r e q VX3 VX 6 /lange body type VX26 /lange body type t y r w t r w e q e q omponent Parts No. escription Material ody onnet iaphragm assembly pset bolt Pilot valve assembly iaphragm assembly for pilot valve N, POM, tainless steel N, POM omponent Parts No. escription Material ody onnet iaphragm assembly pset bolt iaphragm assembly for pilot valve N, POM, tainless steel N, POM eplacement Parts VX()25() VX()26() VX()26() VX()26() VX()27() VX()28() olenoid valve type VX-25 VX-26 VX-26 VX-26 VX-27 VX-28 ir operated type VX-25 VX-26 VX-26 VX-26 VX-27 VX-28 Note) pring is shipped together with the product, but not assembled. iaphragm assembly Note) iaphragm assembly for pilot valve ilencer olenoid valve type ir operated type olenoid valve type N40-04 N40-04 N40-04 N40-04 N40-04 N40-04 ir operated type N40-04 N40-04 N40-04 N40-04 N40-04 N

14 eries imensions: irect piping type /22 /23 (with surge voltage suppressor) 0 0 /4 xhaust port /4 xhaust port 2 x P 2 x P N terminal T able ø6 to ø2 (44) /2 /4 xhaust port 2 x P imensions (mm) P L 2 3 3/4 / (with surge voltage suppressor) N terminal T

15 (32) 2 Port olenoid Valve or ust ollector eries imensions: irect piping type /22 /23 onduit terminal onduit ±2 T±2 VX 280 VX /4 xhaust port /2 2 x P /4 xhaust port /2 2 x P VX VX3 aston terminal VX /4 xhaust port 2 x P imensions (mm) P L 2 3 3/4 / onduit termianl onduit T aston terminal

16 eries imensions: irect piping type 4 (with surge voltage suppressor) /4 xhaust port /4 xhaust port x P 2 x P N terminal /4 xhaust port T 2.5 (44) able ø6 to ø2 /2 2 x P imensions (mm) P L (with surge voltage suppressor) N terminal T

17 2 Port olenoid Valve or ust ollector eries imensions: irect piping type 4 onduit terminal onduit /4 xhaust port T±2 ±2 2.5 (32) /4 280 xhaust port 2.5 VX VX /2 /2 VX 2 P 2 P VX3 VX aston terminal /4 xhaust port P imensions (mm) P L onduit terminal onduit T aston terminal

18 eries imensions: irect piping type 5 /26 (with surge voltage suppressor) /2 xhaust port /2 0 xhaust port P 2 P N terminal /2 xhaust port T 24.4 (44) able ø6 to ø2 /2 2 P imensions (mm) P L / (with surge voltage suppressor) N terminal T

19 2 Port olenoid Valve or ust ollector eries imensions: irect piping type 5 /26 onduit terminal onduit /2 xhaust port ±2 T± (32) /2 xhaust port VX VX /2 /2 VX 2 x P 2 x P VX3 aston terminal VX /2 xhaust port x P imensions (mm) P L / onduit terminal onduit T aston terminal

20 eries imensions: lange type 5 /26 /27 /28 (with surge voltage suppressor) /2 xhaust port (Y) (X) (Y) (X) /2 xhaust port øz øz N terminal /2 xhaust port T able ø6 to ø /2 (44) (Y) (X) Note) efer to page 288 for the dimensions on the mounting side. øz imensions X Y Z L (mm) (with surge voltage suppressor) N terminal T

21 2 Port olenoid Valve or ust ollector eries imensions: lange type 5 /26 /27 /28 onduit terminal onduit /2 xhaust port ±2 T± /2 (32) /2 xhaust port /2 VX VX (Y) (X) øz (Y) (X) øz VX aston terminal VX3 VX /2 xhaust port 24.4 (Y) (X) øz Note) efer to page 288 for the dimensions on the mounting side. imensions (mm) X Y Z L onduit terminal onduit T aston terminal

22 eries imensions on the Mounting ide: lange type x M8 x.25 x 20 / 7 x 45 8 x M0 x.5 x 20 / 7 x ± ± The surface roughness of the orifice machining should be z6.3 or less z ø44 ±0.3 ø76.3 ±0.7 ø65 or more The surface roughness of the orifice machining should be z6.3 or less. ø56 ±0.3 z25 2 ø89. ±0.8 ø80 or more teel tube 8.3 ± teel tube 34 ± x M0 x.5 x 20 / 7 x 45 8 x M0 x.5 x 20 / 7 x ± ±0.2 - The surface roughness of the orifice machining should be z6.3 or less. - The surface roughness of the orifice machining should be z6.3 or less. z25 2 ø56 ±0.3 ø0.6 ±0.8 ø90 or more z25 2 ø56 ±0.3 ø4.3 ±0.8 ø00 or more ± ± teel tube 00 teel tube 288

23 2 Port olenoid Valve or ust ollector eries imensions: lange body type 6 (with surge voltage suppressor) (7) 97.5 ø24 /2 xhaust port (32) N terminal ø x M0 x.5 x /2 xhaust port (32) 97.5 (7) ø24 0 ø x M0 x.5 x VX VX VX VX3 VX /2 xhaust port T able ø6 to ø /2 (44) 97.5 ø24 6 x M0 x.5 x (32) (7) ø06 Note) efer to page 293 for the dimensions on the mounting side. imensions (with surge voltage suppressor) (mm) N terminal T

24 eries imensions: lange body type 6 onduit terminal onduit /2 xhaust port 97.5 ø24 T±2 ± /2 (32) 6 x M0 x.5 x /2 xhaust port 97.5 ø /2 6 x M0 x.5 x (32) (7) ø06 (32) (7) ø06 aston terminal 247 /2 xhaust port 24.4 (32) (7) 97.5 ø24 ø06 6 x M0 x.5 x Note) efer to page 293 for the dimensions on the mounting side. imensions (mm) onduit terminal onduit T aston type

25 2 Port olenoid Valve or ust ollector eries imensions: lange body type 6 (with surge voltage suppressor) /2 xhaust port /2 xhaust port VX VX 8 x M0 x.5 x 75 8 x M0 x.5 x 75 (49) (5) 96 ø24 ø06 (49) 96 (5) ø24 ø06 VX VX3 VX N terminal 206 /2 xhaust port T ableø6 to ø /2 (44) 96 ø24 8 x M0 x.5 x 75 (49) (5) ø06 Note) efer to page 293 for the dimensions on the mounting side. imensions (with surge voltage suppressor) (mm) N terminal T

26 eries imensions: lange body type 6 onduit terminal onduit /2 xhaust port ±2 T± /2 (49) (5) 96 ø24 (32) ø (49) (5) 96 ø24 /2 xhaust port x M0 x.5 x 75 /2 8 x M0 x.5 x 75 ø06 aston terminal /2 xhaust port x M0 x.5 x ø24 (49) (5) ø06 Note) efer to page 293 for the dimensions on the mounting side. imensions onduit terminal onduit T (mm) aston type

27 2 Port olenoid Valve or ust ollector eries imensions on the Mounting ide: lange body / type x M0 x.5 x 20 / 5 x 60 8 x M0 x.5 x 20 / 7 x ± ±0.2 VX VX 6 Piping 6 Piping Piping ø89. ±0.8 ø80 or more 2.5 to 3 80 teel tube Piping ø89. ±0.8 ø80 or more 2.5 to 3 80 teel tube VX VX3 VX 293

28 eries VX2 imensions: irect piping type VX2 VX22 VX23 /4 Pilot port 2 x P imensions VX2 VX22 VX23 P 3/4 / (mm) VX24 /4 Pilot port /4 xhaust port imensions VX x P P L (mm)

29 2 Port ir Operated Valve or ust ollector eries VX2 imensions: irect piping type VX25 VX26 VX VX /4 Pilot port VX /2 xhaust port VX3 VX 2 x P imensions (mm) VX25 VX26 P 2 / L

30 eries VX2 imensions: lange type VX25 VX26 VX27 VX28 /4 Pilot port (Y) (X) /2 xhaust port øz Note) efer to page 297 for the dimensions on the mounting side. imensions Y X VX25 VX26 VX27 VX L (mm) Z

31 Port ir Operated Valve or ust ollector eries VX2 imensions: lange type VX25 8 x M8 x.25 x 20 / - The surface roughness of the orifice machining should be z6.3 or less z ø44 ±0.3 ø76.3 ±0.7 ø65 or more 7 x teel tube ± ±0.2 VX26 8 x M0 x.5 x 20 / - The surface roughness of the orifice machining should be z6.3 or less. ø56 ±0.3 ø89. ± ø80 or more 0.05 z x ± teel tube 34 ±0.2 VX VX VX VX3 VX VX27 VX28 8 x M0 x.5 x 20 / 7 x 45 8 x M0 x.5 x 20 / 7 x ± ±0.2 - The surface roughness of the orifice machining should be z6.3 or less. - The surface roughness of the orifice machining should be z6.3 or less. z25 2 ø56 ±0.3 ø0.6 ±0.8 ø90 or more z25 2 ø56 ±0.3 ø4.3 ±0.8 ø00 or more teel tube 34 ± teel tube 34 ±

32 eries VX2 imensions: lange body / type VX26 VX /2 xhaust port (02.8) (59.8) 43 /4 Pilot port /2 xhaust port (02.8) (59.8) 43 /4 Pilot port 8 x M0 x.5 x ø24 6 x M0 x.5 x 3 96 ø24 (32) (7) ø06 (49) (5) ø06 Note) efer to page 299 for the dimensions on the mounting side. 298

33 2 Port ir Operated Valve or ust ollector eries VX2 imensions on the Mounting ide: lange body / type VX26 VX26 6 x M0 x.5 x 20 / 5 x 60 8 x M0 x.5 x 20 / 7 x ± ±0.2 VX VX VX26 Piping Piping ø89. ±0.8 ø80 or more 2.5 to 3 80 teel tube VX26 Piping Piping ø89. ±0.8 ø80 or more 2.5 to 3 80 teel tube VX VX3 VX 299

34 OT OT2 N N V2 V V4 V3 V6 V5 V8 V7 V0 V or less 38 or less O O eries /VX2 ontroller edicated or Operation/eries VX ow to Order ontroller o VX 06 Number of output points 06 6 output points 0 0 output points pecifications nput voltage Output voltage ON Time setting O Time accuracy Number of outputs Operating ambient temperature Operating ambient humidity Ouput current Power supply fuse Voltage 24 to 48 V -6 2 V 85 to 220 V 06 VX 0 85 to 220 V 24 to 48 V 0.3 or less 3 06 VX 0 ame as input voltage 0.0 to 0.99 sec 0 to 299 sec ±2% 6 to 0 points 0 to 50 (No condensation allowed) 45 to 80% (No condensation allowed) 0.3 or less 5 06 VX V 0.3 or less imensions otary switch for setting output igital switch for setting O time igital switch for setting ON time P switch for setting cascade P switch for setting two-time hitting Terminal block for cascade connection ON O W W2 W to 0.99 sec 0 to 299 sec L L L L OT N POW L L2 L3 L4 L5 L6 L7 L8 L9 L0 ON O Power supply switch Output terminal block ommon terminal block Power supply terminal block 4 x ø4.5 OM 0 or more 2 0

35 eries /VX2 pecific Product Precautions e sure to read before handling. efer to front matter 4 for afety nstructions and pages 7 to 9 and the Operation Manual for 2 Port olenoid Valves for luid ontrol. Please download it via our website, esign Warning. annot be used as an emergency shutoff valve etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. f the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2. xtended periods of continuous energization The solenoid coil will generate heat when continuously energized. void using in a tightly shut container. nstall it in a well-ventilated area. urthermore, do not touch it while it is being energized or right after it is energized. 3. When the conduit type is used as equivalent to an P65 enclosure, install a wiring conduit etc. ilencer aution. The silencer s response properties do not change in the initial stage, but will change due to the blockage after long use. eplace it after using about 500,000 times. This number is subject to change based on fluid quality and energizing time. 2. When using a silencer, make space for silencer replacement. election Warning. ir quality. se clean air. o not use compressed air that contains chemicals, synthetic oils including organic solvents, salt or corrosive gases, etc., as it can cause damage or malfunction. 2. nstall an air filter. nstall an air filter close to the valve on the upstream side. filtration degree of 5 µm or less should be selected. 3. nstall an aftercooler or air dryer, etc. ompressed air that contains excessive drainage may cause malfunction of valves and other pneumatic equipment. To prevent this, install an aftercooler or air dryer, etc. 4. f excessive carbon powder is generated, eliminate it by installing a mist separator on the upstream side of valves. f excessive carbon powder is generated by the compressor, it may adhere to the inside of the valves and cause a malfunction. efer to est Pneumatics No. 5 for further details on compressed air quality. 2 Port olenoid Valve or ust ollector eries /VX2 election Warning 2. mbient environment se within the allowable ambient temperature range. heck the compatibility between the product s composition materials and the ambient atmosphere. e certain that the fluid used VX does not touch the external surface of the product. 3. ountermeasures against static electricity VX Take measures to prevent static electricity since some fluids can cause static electricity. 4. Low temperature operation. The valve can be used in an ambient temperature of between 20 to 0. owever, take measures to prevent freezing or VX solidification of impurities, etc. 2. When using valves for water application in cold climates, take appropriate countermeasures to prevent the water from freezing in tubing after cutting the water supply from the VX3 pump, by draining the water etc. When warming by a heater etc., be careful not to expose the coil portion to a heater. VX nstallation of a dryer, heat retaining of the body is recommended to prevent a freezing condition in which the dew point temperature is high and the ambient temperature is low, and the high flow runs. 5. luid properties se a general compressed air with a filter of 5 µm or less mounted on the inlet of the piping. (xcluding dry air) aution. Leakage voltage Particularly when using a resistor in parallel with a switching element and using a - element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor, - element, etc., creating a possible danger that the valve may not turn off. Power supply witching element O coil: 5% or less of rated voltage coil: 2% or less of rated voltage Leakage current Leakage voltage OL. 2. The response performance and start-up speed deterriorate in case of air operated type (VX2) as compared with a solenoid type () case. efer to the data for pilot piping. 3. Note that for units, idle time and return time increase if the voltage is lowered. f a surge voltage suppressor is installed, the return speed decreases.

36 eries /VX2 pecific Product Precautions 2 e sure to read before handling. efer to front matter 4 for afety nstructions and pages 7 to 9 and the Operation Manual for 2 Port olenoid Valves for luid control. Please download it via our website, 2 Port olenoid Valve or ust ollector eries /VX2 Mounting Warning. f air leakage increases or equipment does not operate properly, stop operation. fter mounting is completed, confirm that it has been done correctly by performing a suitable function test. 2. o not apply external force to the coil section. When tightening is performed, apply a wrench or other tool to the outside of the piping connection parts. 3. Mount a valve with its coil position upward, not downward. When mounting a valve with its coil position downward, foreign objects in the fluid will adhere to the iron core leading to a malfunction. specially for strict leakage control, such as with vacuum applications and non-leak specifications, the coil must be positioned upward. 4. o not warm the coil assembly with a heat insulator etc. se tape, heaters, etc., for freeze prevention on the piping and body only. They can cause the coil to burn out. 5. void sources of vibration, or adjust the arm from the body to the minimum length so that resonance will not occur. 6. Painting and coating Warnings or specifications printed or labeled on the product should not be erased, removed or covered up. Piping Warning. uring use, deterioration of the tube or damage to the fittings could cause tubes to come loose from their fittings and thrash about. To prevent uncontrolled tube movement, install protective covers or fasten tubes securely in place. 2. or piping the tube, fix the product securely using the mounting holes so that the product is not in the air. aution. Preparation before piping efore piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. To prevent uncontrolled tube movement, install protective covers or fasten tubes securely in place. 2. void connecting ground lines to piping, as this may cause electric corrosion of the system. Piping aution 3. lways tighten threads with the proper tightening torque. When attaching fittings to valves, tighten with the proper tightening torque shown below. Tightening Torque for Piping onnection thread Proper tightening torque N m c/4 2 to 4 c3/8 22 to 24 c/2 28 to c3/4 28 to c 36 to 38 c /2 40 to 42 c2 48 to 50 c2 /2 48 to 50 c3 48 to When connecting piping to a product void mistakes regarding the supply port etc. 5. f a regulator, or a restrictor, is installed immediately before or after the N port of the valve, the main valve may oscillate (chatter). nstall them away from the valve or change the restriction. 6. The header tank capacity should be sufficient. This is a valve for large flow rate, so if the capacity is small, the main valve my oscillate due to pressure drop or insufficient air supply. Wiring aution. s a rule, use electrical wire with a cross sectional area of 0.5 to.25 mm 2 for wiring. urthermore, do not allow excessive force to be applied to the lines. 2. se electrical circuits which do not generate chattering in their contacts. 3. se voltage which is within ±0% of the rated voltage. n cases with a power supply where importance is placed on responsiveness, stay within ±5% of the rated value. The voltage drop is the value in the lead wire section connecting the coil. 4. When a surge from the solenoid affects the electrical circuitry, install a surge voltage suppressor etc. in parallel with the solenoid. Or, adopt an option that comes with the surge voltage protection circuit. (owever, a surge voltage occurs even if the surge voltage protection circuit is used. or details, please consult with M.) 2

37 2 eries /VX2 pecific Product Precautions 3 e sure to read before handling. efer to front matter 4 for afety nstructions and pages 7 to 9 and the Operation Manual for 2 Port olenoid Valves for luid ontrol. Please download it via our website, Operating nvironment Warning. o not use in an atmosphere having corrosive gases, chemicals, sea water, water, water vapor, or where there is direct contact with any of these. 2. o not use in explosive atmospheres. 3. o not use in locations subject to vibration or impact. 4. o not use in locations where radiated heat will be received from nearby heat sources. 5. mploy suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc. Warning aution Maintenance. emoving the product The valve becomes hot depending on the fluid temperature. onfirm that the valve temperature has dropped sufficiently before performing work. f touched inadvertently, there is a danger of being burned.. hut off the fluid supply and release the fluid pressure in the system. 2. hut off the power supply. 3. emove the product. 2. Low frequency operation witch valves at least once every days to prevent malfunction. lso, in order to use it under the optimum state, conduct a regular inspection once a half year.. ilters. e careful regarding clogging of filters. 2. eplace filter elements after one year of use, or earlier if the pressure drop reaches 0. MPa. 2. torage n case of long term storage after use, thoroughly remove all moisture to prevent rust and deterioration of rubber materials etc. 3. xhaust the drainage from an air filter periodically. 2 Port olenoid Valve or ust ollector eries /VX2 aution onnector asket lectrical onnections lass coil: W20 Outside insulator diameter of 2.5 mm q w ated voltage 00 V 200 V Other There is no polarity. N terminal ince internal connections are shown below for the N terminal, make connections to the power supply accordingly. Terminal no. N terminal Lead wire color q w lack ed lue lue ed ed ray ray : + ( ) + ( ) (+) inding head screw with flange Tightening torque 0.5 to 0.6 N m Washer ubber seal 2: (+) There is no polarity. se a heavy-duty cord with an outside cable diameter of ø6 to 2 mm. se the tightening torques below for each section. pplicable cable Note) (Outside cable diameter of ø6 to 2 mm) inding head screw Tightening torque 0.5 to 0.6 N m Note) or an outside cable diameter of ø9 to 2 mm, remove the internal parts of the rubber seal before using. VX VX VX VX3 VX 3

38 eries /VX2 pecific Product Precautions 4 e sure to read before handling. efer to front matter 4 for afety nstructions and pages 7 to 9 and the Operation Manual for 2 Port olenoid Valves for luid ontrol. Please download it via our website, 2 Port olenoid Valve or ust ollector eries /VX2 aution lectrical onnections onduit terminal n the case of the conduit terminal, make connections according to the marks shown below. se the tightening torques below for each section. Properly seal the terminal connection (/2) with the special wiring conduit etc. Terminal cover ound head combination screw M3 Tightening torque 0.5 to 0.6 N m (+, ) 2(, +) aution [ circuit], aston terminal OL. Without electrical option lectrical ircuits, N terminal, onduit terminal, onduit (+, ) 2(, +) Varistor OL. With surge voltage suppressor mark mark N terminal, onduit terminal (+, ) Varistor ound head combination screw M3 Tightening torque 0.5 to 0.6 N m View - (nternal connection diagram) onduit terminal /2 Tightening torque 0.5 to 0.6 N m OL. 2(, +) Light With light and surge voltage suppressor onduit When used as an P65 equivalent, use seal to install the wiring conduit. lso, use the tightening torque below for the conduit. lass coil: W20 Outside insulator diameter of 2.5 mm q Lead wire [ circuit], N terminal onduit terminal, onduit Varistor ectifier element OL. N terminal, onduit terminal Varistor ectifier element OL. w Wiring conduit eal ( /2 Tighening torque 0.5 to 0.6 N m) 2 Without electrical option 2 Light With light and surge voltage suppressor ated voltage 00 V 200 V Other There is no polarity. (There is polarity for the power-saving type.) escription eal Note) Please order separately. Lead wire color q w lack ed lue lue ed ed ray ray Part no. VW

39 eries /VX2 pecific Product Precautions 5 e sure to read before handling. efer to front matter 4 for afety nstructions and pages 7 to 9 and the Operation Manual for 2 Port olenoid Valves for luid ontrol. Please download it via our website, ontroller edicated or Operation eries VX Wiring Warning. The controller starts its output the moment the power switch is turned ON. e aware that even if the power switch is turned O, power is connected to the terminal block. aution. Make sure that the power supply voltage to be input matches the voltage in the controller s specifications. The power supply voltage that has been input becomes the voltage that is output to the solenoid valves. 2. onnect a ground that is rated lass 3 or greater to the power supply terminal block s. 3. f the power source is, use caution to its polarity. f the polarity is incorrect, it may result in a malfunction or damage. 4. or details, refer to the separate operation manual. 5. The solenoid valve mounted on the controller should be equipped with a surge voltage suppressor. VX VX VX VX3 VX Operating nvironment Warning. Operate under conditions that are free of vibration and impact. 2. Operate in an ambient temperature range between 0 and Operate in an ambient humidity range between 45% to 85% (with no condensation). 5

2 Port Solenoid Valve/Air Operated Valve For Dust Collector

2 Port Solenoid Valve/Air Operated Valve For Dust Collector 2 Port olenoid Valve/ir Operated Valve or ust ollector VX2/VX2 eries o pplicable for high temperature luid temperature 100 lange type Mounting can be changed depending on the piping conditions! Large port

More information

2 Port Solenoid Valve/Air Operated Valve For Dust Collector. Large port size is available. Flange body type

2 Port Solenoid Valve/Air Operated Valve For Dust Collector. Large port size is available. Flange body type 2 Port olenoid Valve/ir Operated Valve For ust ollector New pplicable for high temperature Fluid temperature 100 Large port size is available. 50 to 100 nclosure P65 lectrical entry flat terminal type

More information

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA Series V irect Operated Port Solenoid Valve for Oil Series V VX VN V VW V V P.-9 Multipurpose Valve for Oil irect Operated Port Solenoid Valve for Oil Series V Kerosene, uel oil class (fuel oil ), Silicone

More information

IP65. Compact Direct Operated 2 Port Solenoid Valve. VDW Series. Aluminum Resin(PPS) g. Brass Stainless Steel. 15 mm mm

IP65. Compact Direct Operated 2 Port Solenoid Valve. VDW Series. Aluminum Resin(PPS) g. Brass Stainless Steel. 15 mm mm ompact irect Operated Port Solenoid Valve Series RoHS ir Medium Water vacuum Lightweight 80 g 00 luminum/resin(pps) body () ompact ody material luminum Resin(PPS) g ir urrent rass body () Water urrent

More information

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W)

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W) igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

High Vacuum Solenoid Valve. 25% reduction. Max. Weight. 18% * lighter. Max. * XSA2-2 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC

High Vacuum Solenoid Valve. 25% reduction. Max. Weight. 18% * lighter. Max. * XSA2-2 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC Normal lose High Vacuum Solenoid Valve Minimum operating pressure * 1x10 6 Pa(abs) * OUT side Leakage Internal 1.3 x10 9 Pa m3/s Note) Note) Except grommet/ RoHS External 1.3 x10 11 Pa m3/s 2 types of

More information

1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C

1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C Normal lose igh Vacuum Solenoid Valve Minimum operating pressure x0 * 6 Pa(abs) * OUT side * * Excluding grommet/ RoS Leakage Internal.3 x0 9 Pa m3/s External.3 x0 Pa m3/s Max. Max. Power consumption 5%

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Coolant Valve. VNC Series. Cylinder actuation by pilot air oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,

More information

Compact / Lightweight 2 Port Solenoid Valve

Compact / Lightweight 2 Port Solenoid Valve ompact / Lightweight 2 Port Solenoid Valve /-XF For ir/water ompact / Lightweight resin body (PPS) Weight: 20 g (-XF) RoHS IP65 mm Power consumption 3 W (Standard) 0.5 W (With power-saving circuit) 48

More information

20% More flow 10% Smaller 30% Lighter

20% More flow 10% Smaller 30% Lighter irect Operated Port Solenoid Valve New low rate ody material ir luminum, esin Water/Oil/ Medium vacuum (rass), Stainless steel ir arge flow rate Medium vacuum ompact Height onventional model Water VX ightweight

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating

More information

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number Doc. no. Coolant valve PRODUCT NAME VNC/VNH Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response

More information

Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve

Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve Zero ifferential Pressure Type Pilot Operated Port Solenoid Valve For ir, Water, Oil Reduced power consumption ( spec.) 7W VXZ:. W 0. W VXZ: 8 W New VX Z Series VXZ/ T.ES70- Solenoid valves for various

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number Doc. no. Process valve PRODUCT NAME VNA Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Design

More information

2 Port Solenoid Valve For Dust Collector

2 Port Solenoid Valve For Dust Collector The VX* series will be revised shortly. 2 Port Solenoid Valve For Dust Collector Series 2 port solenoid valve for dust collector Series In this L-shaped 2 port valve, the bag filter is cleaned by high

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products. Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures, temperatures, etc.,

More information

Valve Mounted Cylinder. Action Built-in magnet. With air cushion. Double acting. Standard. Nonrotating rod. Standard. rod. Standard. rod.

Valve Mounted Cylinder. Action Built-in magnet. With air cushion. Double acting. Standard. Nonrotating rod. Standard. rod. Standard. rod. eries V/MVGQ,,,, 2,,,, 63,, eries Variations eries eries V ction uilt-in magnet With air cushion variations uilt-in One-touch fitting With auto switch With strong scraper Page RE RE X ouble acting -1-

More information

Coolant valve. SGC/SGH Series

Coolant valve. SGC/SGH Series Doc. no. PRODUCT NAME Coolant valve MODEL / Series / Product Number SGC/SGH Series Contents Safety Instructions ------------------------------------------------------------------------------------- 2,3

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Two Hand Control Valve

Two Hand Control Valve Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram

More information

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11 Blow Gun RoHS How to Order VMG W Blow gun Standard type Series Resin body lever type W BU Piping entry Bottom Top Body color White ark blue Symbol Nil 3 4 3 3 4 3 3 33 34 Male High efficiency Low noise

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type 31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

Series VC Direct Operated 2 Port Solenoid Valve for Oil Series VCL

Series VC Direct Operated 2 Port Solenoid Valve for Oil Series VCL T.S0-8 Series V irect Operated Port Solenoid Valve for Oil Series VL Multipurpose Valve for Oil irect Operated Port Solenoid Valve for Oil Series VL Kerosene, uel oil class (fuel oil ), Silicone oil, Machine

More information

Normally Closed Type High Vacuum Straight Solenoid Valve. How to Order XSA S 5 G. Fitting size. Fitting Type

Normally Closed Type High Vacuum Straight Solenoid Valve. How to Order XSA S 5 G. Fitting size. Fitting Type Series XS Normally losed Type igh Vacuum Straight Solenoid Valve ow to Order [Option] Normally closed high vacuum straight solenoid valve XS 1 1 S Solenoid size 1 No.1 No. No. 1 Orifice symbol ø ø ø4.

More information

1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm.

1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm. Pilot Operated -Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS/ Compact and Lightweight Enclosure: IP65 Low-noise construction Operation noise is reduced due to full wave rectifier

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model Blow Gun Series 20% reduction in power consumption with the SMC Blow gun + S coupler + Coil tube 10% reduction with the Blow gun () only RoHS With cover Extension nozzle Added mm and 150 mm lengths Pressure

More information

VNA VNB SGC SGH VNC VNH VND VCC

VNA VNB SGC SGH VNC VNH VND VCC Steam Valve VN Series Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable

More information

Installation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Port Solenoid Valve

Installation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Port Solenoid Valve 2 Specifications Installation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Solenoid Valve For Air, Water, Oil, Heated Water, High Temperature Oil 1 Safety Instructions This

More information

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam. Steam Valve Series VN Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8 G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications

More information

Vacuum Pad: Ball Joint Type

Vacuum Pad: Ball Joint Type Vacuum Pad: all oint Type / eries Pad iameter: ø, ø1, ø, ø,,, ø, ø0 all joint type ideal for adsorption on a slanted work surfaces acaces all joint type ideal for adsorption on a slanted work surfaces

More information

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA Pilot Operated Port Solenoid Valve VXP//3 Series For ir, as,, Water and Oil Variations.O..C. Wide variations of combination. ble to control a wide variety of fluids. Valve can be matched to particular

More information

Technical information for LFU20-Z07-3A-X2

Technical information for LFU20-Z07-3A-X2 Technical information for LFU20-Z07-3A-X2 Ultrasonic flow sensor and flow controller Applications: closed-loop flow control. Also requires fluid regulator (separate part) Ultrasonic flow sensor IN18796_LFU

More information

Series MK ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63

Series MK ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63 otary lamp ylinder/standard Series MK ø, ø, ø, ø, ø, ø, ø5, ø ow to Order MK 1 3 S otary clamp cylinder Mounting Symbol Style ore size Through hole & both ends tapped (Standard) ø, ø oth ends tapped Through

More information

Single Solenoid External Pilot Normally Closed

Single Solenoid External Pilot Normally Closed atalog 000- Operating ressure Internal ilot Solenoid Valves 3/" & 3/" ody 0 to 0 SI (standard) -/" ody to 0 SI (00 SI option available) Series Valves ilot Supply Internal ilot Remote ilot Valve Operating

More information

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2.

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2. Series port direct acting solenoid valve : Open when energized, close when energized NRL PURPOS VLV SRIS iscrete valve irect acting poppet structure Port size : Rc/, Rc/, Rc/, Rc/ JIS symbol / (normally

More information

Pilot Operated/Zero Pressure Differential Operation

Pilot Operated/Zero Pressure Differential Operation ilot Operated/Zero ressure ifferential Operation 2 ort Solenoid Valve Series Z Change of valve style from.c. to.o. is simple. xcellent maintainability Separation of movable iron core and diaphragm valve

More information

Series LVQ. Constructed without screws. Air Operated Chemical Valve Non-Metallic Exterior. Space Saving Type

Series LVQ. Constructed without screws. Air Operated Chemical Valve Non-Metallic Exterior. Space Saving Type ir Operated hemical alve on-etallic Exterior Series LQ onstructed without screws on-metallic construction without using metal screws to fasten the body of the actuator. ody section Integral fitting construction

More information

Doc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series

Doc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series Doc. No. Solenoid Valve PRODUCT NAME VQ4000/5000 (Pilot Valve V100) MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions

More information

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve: Port Valve For Compressed ir and ir-hydro Circuit Control Series VN Style VN -6 VN -8 8 VN - 3 8 VN - 5 VN -5 VN3-0 3 0 Note) This product cannot be used for water application. JIS Symbol

More information

Series AN05 to 40 RoHS

Series AN05 to 40 RoHS Silencer Compact Resin Type/Male Thread N0 to 40 RoHS How to Order N 0 Body size Specifications 0 0 30 40 Thread type M thread Nil R N NPT Thread connection port size pplicable model M 0 0 03 04 M x 0.8

More information

Mechanical Style Pressure Switch. Specifications

Mechanical Style Pressure Switch. Specifications or details about certified products conforming to international standards, visit us at www.smcworld.com. Mechanical Style Pressure Switch Series IS1000 Long service life: 5 million cycles IS1000-01 IS1000-01-X202

More information

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. an remove odor and gas ingredients

More information

Regulator Valve. VEX1 Series

Regulator Valve. VEX1 Series Doc. no. PRODUCT NAME Regulator Valve MODEL / Series / Product Number VEX1 Series Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions

More information

Charts for Solenoid Valve Selection

Charts for Solenoid Valve Selection harts for olenoid election 1. ir flow rate of each series (2-, 3-port) olenoid valve series 062 126 ir flow rate /min [ft. 3 /min.] (N) 200 300400 1000 2000 3000 10000 20000 170 [6.0] 370 [13.1] upply

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

N Series. High Speed Inline Poppet Valves 2 & 3-Way. Section D

N Series. High Speed Inline Poppet Valves 2 & 3-Way. Section D Series igh Speed Inline Poppet Valves & 3-Way Section www.parker.com/pneu/n X Viking Z asic Valve unctions...0 Series asic eatures... ommon Part umbers...-3 Model umber Index...4- Technical Information

More information

NAAMS Standards Compliant Power Clamp Cylinder ø50, ø63

NAAMS Standards Compliant Power Clamp Cylinder ø50, ø63 NORMTON NMS Standards ompliant Power lamp ylinder ø5, ø6 Weight reduced by up to 8% luminum body with greatly reduced weight Suitable for robot material handling ore size KZ2N a New KZN-X2742 Reduction

More information

CAT.ES70-22 A. Series VC. Direct Operated 2 Port Solenoid Valve for Heated Water. Series VCB

CAT.ES70-22 A. Series VC. Direct Operated 2 Port Solenoid Valve for Heated Water. Series VCB CAT.ES0- A Series VC Direct Operated Port Solenoid Valve for Heated Water Series VCB Multipurpose Valve for Heated Water Direct Operated Port Solenoid Valve for Heated Water Series VCB Improved durability

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8 iscrete direct acting 3 port solenoid valve (general purpose valve) 33/43 Series pressurization type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol 33/43: pressurization

More information

Air Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03

Air Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03 In-line type air suction filter is used to prevent vacuum equipment trouble from occurring due to dust in the air IN/OUT straight piping Easy installation and removal with one-touch fittings Light and

More information

Compact and Lightweight. One-touch and screwin connections can be combined.

Compact and Lightweight. One-touch and screwin connections can be combined. Vacuum jector ox Style (uilt-in Silencer)/ody Ported Style Series Z SUP Nozzle diameter ø0.5, ø0.7, ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 Style S: Standard : arge low apacity ompact and ightweight X The nozzle

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B G31/41 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol G31/41: Universal

More information

Pin Cylinders. Series CJP2/CJP. 2 auto switches can even be mounted on a cylinder with ø4 bore size (5 mm stroke). One-touch fitting can be connected.

Pin Cylinders. Series CJP2/CJP. 2 auto switches can even be mounted on a cylinder with ø4 bore size (5 mm stroke). One-touch fitting can be connected. Pin ylinders eries JP/JP auto switches can even be mounted on a cylinder with ø ( mm stroke). uto switch One-touch fitting can be connected. (Panel mount type) ø One-touch fitting, miniature fitting, and

More information

Exhaust Cleaner for Clean Room. Body size. Symbol Nil. Size 1/4 standard 3/8 standard 1/2 standard. Element construction. Stage 2 stage.

Exhaust Cleaner for Clean Room. Body size. Symbol Nil. Size 1/4 standard 3/8 standard 1/2 standard. Element construction. Stage 2 stage. Exhaust Cleaner for Clean oom Series ohs An exhaust cleaner that can be used inside a clean room How to Order 0 0 Exhaust air cleanliness: Equivalent to ISO Class (Class 0 ed.std.0) (Consult SMC in advance,

More information

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)* 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

VAL /2, 5/2, 5/3, and 2 x 3/2 Directional control valves. 3-Port and 5-Port Air Pilot Valves

VAL /2, 5/2, 5/3, and 2 x 3/2 Directional control valves. 3-Port and 5-Port Air Pilot Valves 6-6 eries /, /, /, and x / irectional control valves igh flow rate xtensive manual override options Manifold system with easy assembly ow power consumption Maintenance-free echnical data Medium: ompressed

More information

SMD2. Compact cylinder. Space saving structure 6, 10, 16 20, 25, 32. Simple square design. Switch integrated. Easy centering. Precise installation

SMD2. Compact cylinder. Space saving structure 6, 10, 16 20, 25, 32. Simple square design. Switch integrated. Easy centering. Precise installation pace saving structure Overview his direct mount cylinder is a high rigidity/small square air cylinder with excellent installation accuracy and multisurface direct mount. he square shaped body improves

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Valve Mounted Cylinder. Action Built-in magnet. With air cushion. Double acting. Standard. Nonrotating rod. Standard. rod. Standard. rod.

Valve Mounted Cylinder. Action Built-in magnet. With air cushion. Double acting. Standard. Nonrotating rod. Standard. rod. Standard. rod. eries /, 12,,,,,,, 3,, eries Variations eries eries Action Built-in magnet With air cushion tandard variations Built-in One-touch fitting With auto switch With strong scraper Page CX ouble acting -- CY

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

MHL2. Series 11- ø10, ø16, ø20, ø25. Parallel Type Wide Opening Air Gripper. How to Order. Model/Stroke. Clean series 11 Vacuum suction type

MHL2. Series 11- ø10, ø16, ø20, ø25. Parallel Type Wide Opening Air Gripper. How to Order. Model/Stroke. Clean series 11 Vacuum suction type eries ML2 ø, ø, ø, ø, ø, ø Parallel Type Wide pening ir ripper ow to rder lean series Vacuum suction type ML 2 22 ML 2 MN MN Wide opening Number of fingers 2 2 fingers ore size mm mm mm mm mm mm opper,

More information

Doc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series

Doc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series Doc. No. 3 Port Direct Operated Solenoid Valve PRODUCT NAME VT307 Series MODEL/ Series Contents Safety Instructions ------------------------------------------------------------------------------- 2,3 Precautions

More information

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type Pilot kick type 2 port solenoid valve for dry air (general purpose valve) DK11-Z Series NC (normally closed) type Port size: Rc1/4 to Rc1 Diaphragm structure JIS symbol NC (normally closed) type OUT IN

More information

Float Valve MODEL. Schematic Diagram. Optional Features. Typical Applications. Installation. Product Dimensions Data:

Float Valve MODEL. Schematic Diagram. Optional Features. Typical Applications. Installation. Product Dimensions Data: 2 CF1-C1 Float Control 124-01 (izes 1/2"- 6" Full Internal ort) 624-01 (izes 3"- 8" Reduced Internal ort) Float Valve On-Off or Non-Modulating ction Fully djustable High and Low Level ettings imple Design,

More information

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview HV/HVL For vacuum, inert gas, air, nitrogen HN/G US/G F/G Overview dvanced technology, such as stability in the leak amount (vacuum holding force) and increased seal life, is required when the degree of

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

VX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series

VX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series Zero Differential Pressure Type Pilot Operated Port Solenoid Valve For Air, Water, Oil Reduced power consumption ( spec.) VXZ: 8 W 7 W VXZ:.5 W.5 W New VX Z Z Series VXZ/ CAT.ES7-A Solenoid valves for

More information

Power Clamp Cylinder

Power Clamp Cylinder Power Clamp Cylinder eries New pecial CK /M(D)UK For France CLKZ1R For Europe For North merica CKZ2N MK2T/MK2/MK C(L)KQ For sia CLK2 13 Toggle link mechanism Maintains secure and powerful support. Proximity

More information

Valvair II. Solenoid Operated Directional Spool Valves. Section E.

Valvair II. Solenoid Operated Directional Spool Valves. Section E. (evised 04-05-2012) olenoid Operated irectional pool Valves ection www.parker.com/pneu O IT OT OU. 227 www.comoso.com arker annifin orporation neumatic ivision X odular egulators... 244-245 ccessories...

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Space saving, compact model available

Space saving, compact model available Compact Type High Purity ir Operated Chemical Liquid Valve Series RoHS LV Space saving, compact model available Compact type model is introduced as a new series to complement current series with integrated

More information

Series AN05 to 40 RoHS

Series AN05 to 40 RoHS ompact Resin Type/Male Thread Series N05 to 40 N 02 05 15 30 40 Thread type M thread Nil R N NPT Thread connection port size pplicable model M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 N05 N N15/ N30 N40 Max.

More information

High Purity Chemical Valve Compact Type. Space saving, compact type is available. Piping from 4 directions are possible.

High Purity Chemical Valve Compact Type. Space saving, compact type is available. Piping from 4 directions are possible. High Purity Chemical Valve Compact Type Series Space saving, compact type is available. Compact type is introduced as a new series to complement conventional Series with integral fittings. Select a series

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next Generation Electrical Actuator Realization of Upgraded General-Purpose Actuators The modularization and the adoption of common parts have

More information

General purpose direct acting 2, 3 port solenoid valve

General purpose direct acting 2, 3 port solenoid valve eneral purpose direct acting, 3 port solenoid valve (eneral purpose valve) eneral purpose Direct acting, 3 port solenoid valve / Pilot operated/pilot kick type port solenoid valve P/D/PK/DK Page 9 9 P/

More information

Rotary Actuators Precautions 1 Be sure to read this before handling.

Rotary Actuators Precautions 1 Be sure to read this before handling. Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures or temperatures, etc.,

More information