IP65. Compact Direct Operated 2 Port Solenoid Valve. VDW Series. Aluminum Resin(PPS) g. Brass Stainless Steel. 15 mm mm

Size: px
Start display at page:

Download "IP65. Compact Direct Operated 2 Port Solenoid Valve. VDW Series. Aluminum Resin(PPS) g. Brass Stainless Steel. 15 mm mm"

Transcription

1 ompact irect Operated Port Solenoid Valve Series RoHS ir Medium Water vacuum Lightweight 80 g 00 luminum/resin(pps) body () ompact ody material luminum Resin(PPS) g ir urrent rass body () Water urrent model 5 mm 7 mm luminum body VH Only for air. 4.5 mm 48 mm One-touch fitting ø, ø4, ø6 Resin body SX0 VQ ody material (ompared with, rass/stainless steel body) IP65.5 W 3 W nvironmental performance rass Stainless Steel Medium Water vacuum Power consumption () () rass body Stainless steel body 453 LVM

2 ompact irect Operated Port Solenoid Valve Series ir Medium Water vacuum nclosure IP65 Flame resistance UL94V-0 conformed Flame resistant mold coil material Improved armature durability Low-noise construction Metal noise reduced by the rubber damper Piping variations Screw piping, One-touch fitting IN () Power consumption.5 W () 3 W () Seal material NR (ir, Water) FKM (Medium vacuum) ody material OUT ir luminum () ir Water Resin(PPS) Water Medium vacuum rass, Stainless steel ody material ir Fluid Medium vacuum Water Size Orifice diameter /8 ø ø4 ø6 Other special options luminum Resin(PPS) rass/ Stainless steel (NR) (NR) (NR) (FKM) (NR) Size () Size () Size () Size () Size () Special voltage 48 V 0 V 40 V 4 V V G thread, NPT thread Note ) Oil-free Low concentration ozone resistant, eionized water Note ) (Seal material: FKM) With bracket The materials in ( ) are the seal materials. Note ) s standard for medium vacuum type. Note ) For air, water. 454

3 ompact irect Operated Port Solenoid Valve Series For ir Medium Vacuum Water Standard Specifications Valve specifications oil specifications Step Valve construction Withstand pressure MPa Max. system pressure Note 3) MPa ody material Seal material nclosure nvironment Rated voltage llowable voltage fluctuation llowable leakage voltage oil insulation type Solenoid oil Specifications Select the fluid. Item Select the fluid. (With a full wave rectifier) Normally losed (N..) Specification Size Power consumption (W) Note ) Temperature rise ( ) Note ) Size Size Note ) Power consumption, pparent power: The value at ambient temperature of 0 and when the rated voltage is applied. (Variation: ±0%) Note ) The value at ambient temperature of 0 and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. Selection Steps Selection item Page ir Page 456 Water Page 460 Medium vacuum Page 458 irect operated poppet.0 (resin body type.5).0 luminum, Resin, rass, Stainless steel NR, FKM usttight, Low jetproof (IP65) Note ) Location without corrosive or explosive gases 00 V, 00 V, 0 V, 30 V, (0 V, 40 V, 48 V, 4 V) Note ) 4 V, ( V) Note ) ±0% of rated voltage 5% or less of rated voltage % or less of rated voltage lass e sure to read Specific Product Precautions before handling. Note ) Voltage in ( ) indicates special voltage. (Refer to page 46.) Note ) For enclosure, refer to Glossary of Terms on page 466. When using the product in a place which requires water resistance, please contact SM. Note 3) Refer to Glossary of Terms on page 466 for details on the maximum system pressure. Specification (With a full wave rectifier) Size Size Size Symbol 0 4 pparent power (V) Note ) ) Temperature rise ( ) Note 3) Note ) Power consumption, pparent power: The value at ambient temperature of 0 and when the rated voltage is applied. (Variation: ±0%) Note ) There is no difference in the frequency and the inrush and energized apparent power, since a rectifying circuit is used in the (with a full wave rectifier). Note 3) The value at ambient temperature of 0 and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. 0 VH SX0 VQ LVM Step Select ody material, and Orifice diameter from Flow rate Pressure of each fluid. Item Select from Flow rate Pressure. ody material Orifice diameter Selection item Size ody material Orifice diameter Size Resin Symbol 0 Step 3 Select electric specifications. Item Select electric specifications. Selection item Voltage 4 V lectrical entry Symbol 0 Step 4 For other special options, refer to page

4 Series For ir Single Unit /Valve Specifications N.. Symbol Note) The symbol shows ports and as blocked, but there is actually a limit to the blocking capability when the pressure of port is greater than the pressure of port. Please contact SM when low leakage performance is required. Normally losed (N..) luminum ody Type Size, /8 Orifice diameter (mmø) 0 Flow rate characteristics show those when the port size is /8 (size ). Maximum operating Note ) Flow rate characteristics Note ) pressure differential (MPa) Weight [dm 3 /(s bar)] b v Pressurized port (g) Resin ody Type (uilt-in One-touch Fittings) Flow rate characteristics show those when the One-touch fitting with a port size of ø4 (size or ) is used. Size Orifice Maximum operating Note ) Flow rate characteristics Note ) diameter pressure differential (MPa) Weight (g) (mmø) [dm 3 /(s bar)] b v Pressurized port ø One-touch fitting 0 45 ø4 One-touch fitting ø4 One-touch fitting ø6 One-touch fitting Note ) The flow rate characteristics of this product have variations. When the highly precise flow control is required according to the system to be used, select an orifice diameter.3 times larger than that shown above and install a restrictor on the downstream side of the solenoid valve to make the adjustment. Note ) Refer to Glossary of Terms on page 466 for details on the maximum operating pressure differential. Fluid and mbient Temperature Fluid temperature ( ) mbient temperature ( ) 0 Note) to 50 0 to 50 Note) ew point temperature: 0 or less Valve Leakage Internal Leakage Seal material Leakage rate (ir) Note) cm 3 /min or less (Iuminum body type) NR 5 cm 3 /min or less (Resin body type) xternal Leakage Seal material Leakage rate (ir) Note) cm 3 /min or less (Iuminum body type) NR 5 cm 3 /min or less (Resin body type) Note) Leakage is the value at ambient temperature

5 ompact irect Operated Port Solenoid Valve Series For ir Single Unit How to Order (Single Unit) RoHS Size/Valve type Valve Symbol Size type Size () Size () Single unit N.. Single unit N.. ody material//orifice diameter Symbol F F G H J K L M N P Q ody material Resin (PPS) With bracket Resin (PPS) With bracket luminum 0 ø One-touch fitting ø4 One-touch fitting ø4 One-touch fitting ø6 One-touch fitting /8 Fluid 0 For air Orifice diameter Voltage/lectrical entry Symbol Voltage lectrical entry Z 4 V 00 V 0 V 00 V 30 V ommon Specifications Valve type N.. Seal material NR oil insulation type lass Thread type Rc One-touch fittings are attached to the resin body type. Other voltages For other special options, refer to page V 0 V Special voltage 40 V 4 V V Low concentration ozone resistant (Seal material: FKM) Oil-free G thread NPT thread With bracket (luminum body only) imensions Page 463 (Single unit) VH SX0 VQ LVM 457

6 Series For Medium Vacuum This valve can also be used with air. (Refer to the valve specifications on page 456 for air.) Single Unit /Valve Specifications N.. Symbol (pplication example) Used with vacuum Used with pressure Normally losed (N..) Size, /8 Orifice diameter (mmø) Note) The symbol shows ports and as blocked, but there is actually a limit to the blocking capability when the pressure of port is greater than the pressure of port. Please contact SM when low leakage performance is required. Flow rate characteristics show those when the port size is (size ) or /8 (size ). Flow rate characteristics Note ) Maximum operating Weight pressure differential [dm 3 /(s bar)] b v (MPa) Note ) (g) rass: Stainless steel: rass: 5 Stainless steel: Note ) The flow rate characteristics of this product have variations. When the highly precise flow control is required according to the system to be used, select an orifice diameter.3 times larger than that shown above and install a restrictor on the downstream side of the solenoid valve to make the adjustment. Note ) Refer to Glossary of Terms on page 466 for details on the maximum operating pressure differential. Fluid and mbient Temperature Fluid temperature ( ) Note) With no freezing mbient temperature ( ) Valve Leakage Internal Leakage Seal material to 50 0 to 50 FKM xternal Leakage Seal material FKM Leakage rate Note) 0 6 Pa m 3 /sec or less Leakage rate Note) 0 6 Pa m 3 /sec or less Note) Leakage (0 6 Pa m 3 /sec) is the value at 0. Pa abs and ambient temperature

7 ompact irect Operated Port Solenoid Valve Series For Medium Vacuum Single Unit How to Order (Single Unit) Fluid 4 For medium vacuum 4 RoHS ommon Specifications Valve type N.. Seal material oil insulation type Thread type Oil-free FKM lass Rc Size/Valve type ody material//orifice diameter Voltage/lectrical entry Symbol Size Symbol Symbol Voltage lectrical entry Size () Size () Valve type Single unit N.. Single unit N.. G H J K K L M N P Q R S T U V W ody material rass Stainless steel rass Stainless steel /8 /8 Orifice diameter.0.0 Z 4 V 00 V 0 V 00 V 30 V Other voltages For other special options, refer to page V 0 V Special voltage 40 V 4 V V G thread NPT thread With bracket VH imensions Page 463 (Single unit) SX0 VQ LVM 459

8 Series For Water Single Unit This valve can also be used with air. (Refer to the valve specifications on page 456 for air.) /Valve Specifications N.. Symbol Note) The symbol shows ports and as blocked, but there is actually a limit to the blocking capability when the pressure of port is greater than the pressure of port. Please contact SM when low leakage performance is required. Normally losed (N..) 37, Stainless Steel ody Type Size, /8 Orifice diameter (mmø).0 Flow rate characteristics show those when the port size is (size ) or /8 (size ). Maximum operating Note ) Flow rate characteristics Note ) pressure differential (MPa) Weight (g) Kv onversion v Pressurized port rass: 65 Stainless steel: 60 rass: 5 Stainless steel: 00 Resin ody Type Size ø One-touch fitting ø4 One-touch fitting ø4 One-touch fitting ø6 One-touch fitting Flow rate characteristics show those when the One-touch fitting with a port size of ø4 (size or ) is used. Orifice Maximum operating Note ) Flow rate characteristics Note ) Weight diameter pressure differential (MPa) (g) (mmø) Kv onversion v Pressurized port Note ) The flow rate characteristics of this product have variations. When the highly precise flow control is required according to the system to be used, select an orifice diameter.3 times larger than that shown above and install a restrictor on the downstream side of the solenoid valve to make the adjustment. Note ) Refer to Glossary of Terms on page 466 for details on the maximum operating pressure differential. Fluid and mbient Temperature Fluid temperature ( ) mbient temperature ( ) to 50 0 to 50 Note) With no freezing Valve Leakage Internal Leakage Note ) Internal leakage when pressure is supplied to Port (IN). Seal material Leakage rate (Water) Note ) 0. cm 3 /min or less (37, Stainless steel body type) NR cm 3 /min or less (Resin body type) xternal Leakage Seal material Leakage rate (Water) Note ) 0. cm 3 /min or less (37, Stainless steel body type) NR cm 3 /min or less (Resin body type) Note ) Leakage is the value at ambient temperature

9 ompact irect Operated Port Solenoid Valve Series For Water Single Unit How to Order (Single Unit) RoHS Size () Size () Single unit N.. Single unit N.. F G H J K F G H J K L M N P Q R S T U V W Resin (PPS) (With bracket) rass Stainless steel Resin (PPS) (With bracket) rass Stainless steel ø One-touch fitting ø4 One-touch fitting ø4 One-touch fitting ø6 One-touch fitting /8 /8 Fluid For water Z 4 V 00 V 0 V 00 V 30 V ommon Specifications Valve type N.. Seal material NR oil insulation type lass Thread type Rc One-touch fittings are attached to the resin body type. Size/Valve type ody material//orifice diameter Voltage/lectrical entry Valve ody Orifice Symbol Size Symbol Symbol Voltage lectrical entry type material diameter Other voltages For other special options, refer to page V 0 V Special voltage 40 V 4 V V eionized water (Seal material: FKM) Oil-free G thread NPT thread racket interchangeable with old type With bracket (rass, Stainless steel body only) imensions Page 463 (Single unit) VH SX0 VQ LVM 46

10 Series Other Special Options U lectrical options (Special voltage) 0 Z nter standard product number. lectrical option lectrical option (Special voltage) Specification Special voltage Symbol Voltage 48 V 0 V 40 V 4 V V lectrical entry pplicable for air type ( 0) and water type ( ). When G or NPT is selected, choose the /8 port size standard model. 3 When M6 is selected, choose the port size standard model. 4 When using deionized water or any other fluid that may corrode 37 (brass), select a stainless steel body. Other options (Low concentration ozone resistant, eionized water, oil-free, special thread) 0 Z nter standard product number. Other option (Low concentration ozone resistant, eionized water, oil-free, special thread) Low concentration ozone, 4, 3 Symbol resistant, eionized water Oil-free Special (Seal material: FKM) thread Nil Z (Standard) G/8 NPT/8 M6 (Standard) G/8 NPT/8 F G M6 (Standard) H G/8 J NPT/8 K L M6 (Standard) M G/8 N NPT/8 P M6 racket interchangeable with old type The brackets are interchangeable with brackets of old 0/0 series. For details of exterior dimensions, please contact SM. nter standard product number. racket interchangeable with old type (Shipped together) nter standard product number. With bracket (Shipped together) Y x ø3.4 W Mounting hole M U X X X [mm] racket part no. Size M U W X Y : S-- : S-- nter symbols in the order to the right when ordering a combination of electrical option, other options, and bracket interchangeable with old type. onstruction Normally closed (N..) ody material: luminum, PPS resin, rass, Stainless steel xample) 0 Z Z X lectrical option Other option racket interchangeable with old type ody material: PPS resin (One-touch fitting type) q w e r t y u q w e r t y u IN omponent Parts No. escription Solenoid coil Fixed armature 3 Tube 4 Return spring 5 rmature assembly 6 Seal 7 ody 46 OUT Material u + Fe + Resin Fe Stainless steel Stainless steel NR, FKM, Stainless steel, PPS resin NR, FKM luminum, PPS resin, rass, Stainless steel IN omponent Parts No. escription Solenoid coil Fixed armature 3 Tube 4 Return spring 5 rmature assembly 6 Seal 7 ody 8 racket OUT i Material u + Fe + Resin Fe Stainless steel Stainless steel NR, FKM, Stainless steel, PPS resin NR, FKM PPS resin SP

11 ompact irect Operated Port Solenoid Valve Series imensions/single Unit ir Medium Water vacuum ody material luminum x ø3.4 Mounting hole Y W U X 300 Q F R Full wave rectifier ( type) x P G Mounting bracket dimensions (X) lectrical entry F P G U W X Y Q R, / [mm] VH SX0 VQ LVM Made to Order <Special lead wire length> Produced upon receipt of order. Please contact SM for lead times. XL Lead wire length XL 600 mm XL 000 mm XL3 500 mm XL mm 463

12 Series imensions/single Unit ir, Medium Vacuum, Water ody material Resin With One-touch fittings x ø3.4 Mounting hole Y W U X 300 Q F R Full wave rectifier ( type) For information on handling One-touch fittings and appropriate tubing, refer to page 69 and the KQ series One-touch fittings (est Pneumatics No. 7). x P One-touch fitting P F [mm] ø, ø ø4, ø Mounting bracket dimensions lectrical entry One-touch fitting P U W X Y Q R ø, ø ø4, ø /M6 x ø3.4 Mounting hole Y W U X 300 Q F R Full wave rectifier ( type) x P P F [mm] (M6) (M6) Mounting bracket dimensions lectrical entry P U W X Y Q R (M6) (M6)

13 ompact irect Operated Port Solenoid Valve Series imensions/single Unit ody material rass x ø3.4 Mounting hole Y W ir Medium Water vacuum U X 300 Q F R Full wave rectifier ( type) x P G P F [mm] Mounting method J K M M.5 4, / M3 5 5 x J thread depth K M x ø3.4 Mounting hole Y W U X Mounting bracket dimensions (X) lectrical entry P G U W X Y Q R , / VH ody material Stainless Steel SX0 VQ LVM 300 Q F R Full wave rectifier ( type) P F [mm] Mounting method J K M x P G M M.5 4, / M3 5 5 Mounting bracket dimensions (X) lectrical entry P G U W X Y Q R , / x J thread depth K 465

14 Series Glossary of Terms Pressure Terminology. Maximum operating pressure differential The maximum pressure differential (the difference between the inlet and outlet pressure) which is allowed for operation. When the outlet pressure is 0 MPa, this becomes the maximum operating pressure.. Maximum system pressure The maximum pressure that can be applied inside the pipelines (line pressure). [The pressure differential in the solenoid valve portion must be less than the maximum operating pressure differential.] 3. Withstand pressure The pressure in which the valve must be withstood without a drop in performance after holding for one minute under prescribed (static) pressure and returning to the operating pressure range. [value under the prescribed conditions] Others. Material NR: Nitrile rubber FKM: Fluororubber. Oil-free treatment The degreasing and washing of wetted parts 3. Symbol Symbol ( ) IN and OUT are in a blocked condition ( ), but actually in the case of reverse pressure (OUT> IN), there is a limit to the blocking. Product with flow direction with pressure supplied to port and universal specification product are available as specials. lectrical Terminology. Surge voltage high voltage which is momentarily generated by shutting off the power in the shut-off area.. nclosure degree of protection defined in the JIS 090: Waterproof test of electric machinery/appliance and the degree of protection against the intrusion of solid foreign objects. Verify the degree of protection for each product. IP Second characteristic numeral First characteristic numeral First haracteristics: egrees of protection against solid foreign objects 0 Non-protected Protected against solid foreign objects of ø50 mm and greater Protected against solid foreign objects of ø mm and greater 3 Protected against solid foreign objects of ø.5 mm and greater 4 Protected against solid foreign objects of ø.0 mm and greater 5 ust-protected 6 usttight Second haracteristics: egrees of protection against water Non-protected Protected against vertically falling water drops Protected against vertically falling water drops when enclosure tilted up to 5 Protected against rainfall when enclosure tilted up to 60 Protected against splashing water Protected against water jets Protected against powerful water jets Protected against the effects of temporary immersion in water Protected against the effects of continuous immersion in water ripproof type ripproof type Rainproof type Splashproof type Low jetproof type Strong jetproof type Immersible type Submersible type xample) IP65: usttight, Low jetproof type Low jetproof type means that no water intrudes inside an equipment that could hinder from operating normally by means of applying water for 3 minutes in the prescribed manner. Take appropriate protection measures, since a device is not usable in an environment where a droplet of water is splashed constantly. 466

15 Series Specific Product Precautions e sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 7 to 9 for Port Solenoid Valve for Fluid ontrol Precautions. Warning esign. annot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted.. xtended periods of continuous energization The solenoid coil will generate heat when continuously energized. void using in a tightly shut container. Install it in a well-ventilated area. Furthermore, do not touch it while it is being energized or right after it is energized. 3. Liquid rings In cases with a flowing liquid, provide a bypass valve in the system to prevent the liquid from entering the liquid seal circuit. 4. ctuator drive When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation. 5. Pressure (including vacuum) holding It is not usable for an application such as holding the pressure (including vacuum) inside of a pressure vessel because air leakage is entailed in a valve. 6. When an impact, such as water hammer, etc., caused by the rapid pressure fluctuation is applied, the solenoid valve may be damaged. Give an attention to it. Selection Warning. Fluid ) Type of fluid efore using a fluid, check whether it is compatible with the materials of each model by referring to the fluids listed in this catalog. Use a fluid with a kinematic viscosity of 50 mm /s or less. If there is something you do not know, please contact SM. ) Flammable oil, Gas onfirm the specification for leakage in the interior and/or exterior area. 3) orrosive gas annot be used since it will lead to cracks by stress corrosion or result in other incidents. 4) epending on water quality, a brass body can cause corrosion and internal leakage may occur. If such abnormalities occur, exchange the product for a stainless steel body. 5) Use an oil-free specification when any oily particle must not enter the passage. 6) pplicable fluid on the list may not be used depending on the operating condition. Give adequate confirmation, and then determine a model, just because the compatibility list shows the general case. Warning Selection. Fluid quality <ir> ) Use clean air. o not use compressed air that contains chemicals, synthetic oils including organic solvents, salt or corrosive gases, etc., as it can cause damage or malfunction. ) Install an air filter. Install air filters close to the valves on the upstream side. filtration degree of 5 µm or less should be selected. 3) Install an aftercooler or air dryer, etc. ompressed air that contains excessive drainage may cause malfunction of valves and other pneumatic equipment. To prevent this, install an aftercooler or air dryer, etc. 4) If excessive carbon powder is generated, eliminate it by installing mist separators at the upstream side of valves. If excessive carbon powder is generated by the compressor, it may adhere to the inside of the valves and cause a malfunction. Refer to est Pneumatics No.7 for further details on compressed air quality. <Vacuum> Please be aware that there is a range of pressure that can be used. tmospheric pressure Low ir pressure vacuum Medium vacuum vacuum High Ultra high vacuum Hydraulic pressure <Suction filtration, Vacuum bottle set, Suction cup> ifferential pressure Torr (mmhg) Pa rying ischarge/plasma <ccelerator, lectron microscope> Vapor deposition harged particle beam Neon tube/fluorescent light Surface physics xtreme high vacuum Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump on the secondary side (Port ). lso, install a filter on the primary side (Port ), and be careful that no foreign object is picked up. Please replace the valve after operating the device approximately 300,000 times. VH SX0 VQ LVM 467

16 Series Specific Product Precautions e sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 7 to 9 for Port Solenoid Valve for Fluid ontrol Precautions. Selection Warning <Water> The use of a fluid that contains foreign objects can cause problems such as malfunction and seal failure by promoting wear of the valve seat and armature and by sticking to the sliding parts of the armature etc. Install a suitable filter (strainer) immediately upstream from the valve. s a general rule, use 00 mesh. The supply water includes materials that create a hard sediment or sludge such as calcium and magnesium. Since this scale and sludge can cause the valve to malfunction, install water softening equipment, and a filter (strainer) directly upstream from the valve to remove these substances. Tap water pressure: The water pressure for tap water is normally 0.4 MPa or less. However, in places like a high-rise building, the pressure may be.0 MPa. When selecting tap water, be careful of the maximum operating pressure differential. When using water or heated water, poor operation or leaks may be caused by dezincification, erosion, corrosion, etc. The brass (rass) body of this product uses dezincification resistant material as a standard. We also offer a stainless steel body type with improved corrosion resistance. Please use the one that fits your needs. 3. mbient environment Use within the operable ambient temperature range. heck the compatibility between the product s composition materials and the ambient atmosphere. e certain that the fluid used does not touch the external surface of the product. 4. ountermeasures against static electricity Take measures to prevent static electricity since some fluids can cause static electricity. 5. Low temperature operation ) The valve can be used in an ambient temperature of between 0 to 0. However, take measures to prevent freezing or solidification of impurities, etc. ) When using valves for water application in cold climates, take appropriate countermeasures to prevent the water from freezing in tubing after cutting the water supply from the pump, by draining the water etc. When warming by a heater etc., be careful not to expose the coil portion to a heater. Installation of a dryer, heat retaining of the body is recommended to prevent a freezing condition in which the dew point temperature is high and the ambient temperature is low, and the high flow runs. Selection aution. Leakage voltage When the solenoid valve is operated using the controller, etc., the leakage voltage should be the product allowable leakage voltage or less. Particularly when using a resistor in parallel with a switching element and using a -R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor, -R element, etc., creating a possible danger that the valve may not turn off. Power supply Switching element OFF R Leakage current Mounting Leakage voltage SOL. /lass built-in full wave rectifier coil: 5% or less of rated voltage coil: % or less of rated voltage. Selecting model Material depends on fluid. Select optimal models for the fluid. Warning. If air leakage increases or equipment does not operate properly, stop operation. fter mounting is completed, confirm that it has been done correctly by performing a suitable function test.. o not apply external force to the coil section. When tightening is performed, apply a wrench or other tool to the outside of the piping connection parts. 3. Mount a valve with its coil position upwards, not downwards. When mounting a valve with its coil positioned downwards, foreign objects in the fluid will adhere to the iron core leading to a malfunction. specially for strict leakage control, such as with vacuum applications and non-leak specifications, the coil must be positioned upwards. 4. o not warm the coil assembly with a heat insulator, etc. Use tape, heaters, etc., for freeze prevention on the piping and body only. They can cause the coil to burn out. 5. Secure with brackets, except in the case of steel piping and copper fittings. 6. void sources of vibration, or adjust the arm from the body to the minimum length so that resonance will not occur. 7. Painting and coating Warnings or specifications printed or labeled on the product should not be erased, removed or covered up. 468

17 Series Specific Product Precautions 3 e sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 7 to 9 for Port Solenoid Valve for Fluid ontrol Precautions. Piping Warning. uring use, deterioration of the tube or damage to the fittings could cause tubes to come loose from their fittings and thrash about. To prevent uncontrolled tube movement, install protective covers or fasten tubes securely in place.. For piping the tube, fix the product securely using the mounting holes so that the product is not in the air. aution. Preparation before piping efore piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. Install piping so that it does not apply pulling, pressing, bending or other forces on the valve body.. void connecting ground lines to piping, as this may cause electric corrosion of the system. 3. Tighten threads with the proper tightening torque. When using steel piping, tighten with the proper tightening torque shown below. Lower tightening torque will lead into fluid leakage. Tightening Torque for Piping onnection thread Proper tightening torque (N m) to.5 M6 to.5 Rc/8 7 to 9 For resin bodies, the proper tightening torque is 0.4 to 0.6 N m (reference value). fter tightening by hand, tighten by an additional /6th rotation with a tightening tool. 4. onnection of piping to products When connecting piping to a product, refer to its operation manual to avoid mistakes regarding the supply port, etc. 5. Winding of sealant tape When connecting pipes, fittings, etc., be sure that chips from the pipe threads and sealing material do not enter the valve. Furthermore, when sealant tape is used, leave.5 to thread ridges exposed at the end of the threads. xpose approx. threads Winding direction Sealant tape 6. In applications such as vacuum and non-leak specifications, use caution specifically against the contamination of foreign objects or airtightness of the fittings. Recommended Piping onditions. When connecting tubes using one-touch fittings, provide some spare tube length shown in Fig., recommended piping configuration. lso, do not apply external force to the fittings when binding tubes with bands, etc. (see Fig..) Tube size ø ø4 ø6 Straight portion Mounting pitch Fig. Recommended piping configuration Mounting pitch Nylon tube Soft nylon tube Polyurethane tube 44 or more 56 or more 84 or more Recommended 9 or more 30 or more 39 or more Wiring 5 or more 6 or more 39 or more Unacceptable Fig. inding tubes with bands Unit: mm Straight portion length 6 or more 0 or more 30 or more aution. s a rule, use electric wire with a cross sectional area of 0.5 to.5 mm for wiring. Furthermore, do not allow excessive force to be applied to the lines.. Use electric circuits which do not generate chattering in their contacts. 3. Use voltage which is within ±0% of the rated voltage. In cases with a power supply where importance is placed on responsiveness, stay within ±5% of the rated value. The voltage drop is the value in the lead wire section connecting the coil. VH SX0 VQ LVM 469

18 Series Specific Product Precautions 4 e sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 7 to 9 for Port Solenoid Valve for Fluid ontrol Precautions. aution Operating nvironment Warning. o not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these.. o not use in explosive atmospheres. 3. o not use in locations subject to vibration or impact. 4. o not use in locations where radiated heat will be received from nearby heat sources. 5. mploy suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc. Warning Maintenance. Removing the product The valve will reach a high temperature when used with high temperature fluids. onfirm that the valve temperature has dropped sufficiently before performing work. If touched inadvertently, there is a danger of being burned. ) Shut off the fluid supply and release the fluid pressure in the system. ) Shut off the power supply. 3) Remove the product.. Low frequency operation Switch valves at least once every 30 days to prevent malfunction. lso, in order to use it under the optimum state, conduct a regular inspection once a half year.. Filters and strainers ) e careful regarding clogging of filters and strainers. ) Replace filter elements after one year of use, or earlier if the pressure drop reaches 0. MPa. 3) lean strainers when the pressure drop reaches 0. MPa.. Lubrication When using after lubricating, never forget to lubricate continuously. 3. Storage In case of long term storage after use with heated water, thoroughly remove all moisture to prevent rust and deterioration of rubber materials, etc. 4. xhaust the drainage from an air filter periodically. Operating Precautions Warning When problems are caused by a water hammer, install water hammer relief equipment (accumulator, etc.), or use an SM water hammer relief valve (VXR series). For details, please consult with SM. 470 aution Operating Precautions When operating the product with flow direction with pressure supplied to port, there is a risk of the valve opening momentarily and fluid leaking to the downstream side due to a rapid increase of the upstream pressure. special product will be available when holding pressure supplied from port in the flow direction with low leakage performance is required. Universal specification special can be available for Universal Specification, where product operation can be both flow from port to port ( ) and from port to port ( ). aution lectric onnections lass coil: WG0 Outside insulator diameter of.8 mm port q w aution [ circuit] (+, ) (, +) lectric ircuits Varistor Lead wire color Rated voltage q w 00 V 00 V Other lack lue Red Gray Red lue Red Gray There is no polarity. SOL. [ circuit] For (lass ), the standard product is equipped with surge voltage suppressor. Rectifier element SOL. One-touch Fitting aution For information on handling One-touch fittings and appropriate tubing, refer to page 469 and the KQ series One-touch fittings (est Pneumatics No. 7).

Compact / Lightweight 2 Port Solenoid Valve

Compact / Lightweight 2 Port Solenoid Valve ompact / Lightweight 2 Port Solenoid Valve /-XF For ir/water ompact / Lightweight resin body (PPS) Weight: 20 g (-XF) RoHS IP65 mm Power consumption 3 W (Standard) 0.5 W (With power-saving circuit) 48

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

High Vacuum Solenoid Valve. 25% reduction. Max. Weight. 18% * lighter. Max. * XSA2-2 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC

High Vacuum Solenoid Valve. 25% reduction. Max. Weight. 18% * lighter. Max. * XSA2-2 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC Normal lose High Vacuum Solenoid Valve Minimum operating pressure * 1x10 6 Pa(abs) * OUT side Leakage Internal 1.3 x10 9 Pa m3/s Note) Note) Except grommet/ RoHS External 1.3 x10 11 Pa m3/s 2 types of

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm.

1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm. Pilot Operated -Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS/ Compact and Lightweight Enclosure: IP65 Low-noise construction Operation noise is reduced due to full wave rectifier

More information

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA Series V irect Operated Port Solenoid Valve for Oil Series V VX VN V VW V V P.-9 Multipurpose Valve for Oil irect Operated Port Solenoid Valve for Oil Series V Kerosene, uel oil class (fuel oil ), Silicone

More information

20% More flow 10% Smaller 30% Lighter

20% More flow 10% Smaller 30% Lighter irect Operated Port Solenoid Valve New low rate ody material ir luminum, esin Water/Oil/ Medium vacuum (rass), Stainless steel ir arge flow rate Medium vacuum ompact Height onventional model Water VX ightweight

More information

1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C

1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C Normal lose igh Vacuum Solenoid Valve Minimum operating pressure x0 * 6 Pa(abs) * OUT side * * Excluding grommet/ RoS Leakage Internal.3 x0 9 Pa m3/s External.3 x0 Pa m3/s Max. Max. Power consumption 5%

More information

Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve

Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve Zero ifferential Pressure Type Pilot Operated Port Solenoid Valve For ir, Water, Oil Reduced power consumption ( spec.) 7W VXZ:. W 0. W VXZ: 8 W New VX Z Series VXZ/ T.ES70- Solenoid valves for various

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Coolant Valve. VNC Series. Cylinder actuation by pilot air oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

2 Port Solenoid Valve/Air Operated Valve For Dust Collector

2 Port Solenoid Valve/Air Operated Valve For Dust Collector 2 Port olenoid Valve/ir Operated Valve or ust ollector eries /VX2 Large port size is available. 50 to 00 added lange type Mounting can be changed depending on the piping conditions. Piping lange type,

More information

Installation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Port Solenoid Valve

Installation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Port Solenoid Valve 2 Specifications Installation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Solenoid Valve For Air, Water, Oil, Heated Water, High Temperature Oil 1 Safety Instructions This

More information

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating

More information

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number Doc. no. Coolant valve PRODUCT NAME VNC/VNH Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

2 Port Solenoid Valve/Air Operated Valve For Dust Collector. Large port size is available. Flange body type

2 Port Solenoid Valve/Air Operated Valve For Dust Collector. Large port size is available. Flange body type 2 Port olenoid Valve/ir Operated Valve For ust ollector New pplicable for high temperature Fluid temperature 100 Large port size is available. 50 to 100 nclosure P65 lectrical entry flat terminal type

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating

More information

Two Hand Control Valve

Two Hand Control Valve Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

80 g IP g. New. New. Compact Direct Operated 2 Port Solenoid Valve New. Aluminium s Resin(PPS) Brass s Stainless Steel. 15 mm. 42.

80 g IP g. New. New. Compact Direct Operated 2 Port Solenoid Valve New. Aluminium s Resin(PPS) Brass s Stainless Steel. 15 mm. 42. ompact irect Operated ort Solenoid Valve New RoHS ir Lightweight 00 g Medium Water vacuum 80 g onventional rass bo body ody (Size ) luminium/resin(s) body dy (Size ) ody material luminium s Resin(S) ir

More information

VX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series

VX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series Zero Differential Pressure Type Pilot Operated Port Solenoid Valve For Air, Water, Oil Reduced power consumption ( spec.) VXZ: 8 W 7 W VXZ:.5 W.5 W New VX Z Z Series VXZ/ CAT.ES7-A Solenoid valves for

More information

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number Doc. no. Process valve PRODUCT NAME VNA Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Design

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

2 Port Solenoid Valve/Air Operated Valve For Dust Collector

2 Port Solenoid Valve/Air Operated Valve For Dust Collector 2 Port olenoid Valve/ir Operated Valve or ust ollector VX2/VX2 eries o pplicable for high temperature luid temperature 100 lange type Mounting can be changed depending on the piping conditions! Large port

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Air Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03

Air Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03 In-line type air suction filter is used to prevent vacuum equipment trouble from occurring due to dust in the air IN/OUT straight piping Easy installation and removal with one-touch fittings Light and

More information

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model Blow Gun Series 20% reduction in power consumption with the SMC Blow gun + S coupler + Coil tube 10% reduction with the Blow gun () only RoHS With cover Extension nozzle Added mm and 150 mm lengths Pressure

More information

CAT.ES70-22 A. Series VC. Direct Operated 2 Port Solenoid Valve for Heated Water. Series VCB

CAT.ES70-22 A. Series VC. Direct Operated 2 Port Solenoid Valve for Heated Water. Series VCB CAT.ES0- A Series VC Direct Operated Port Solenoid Valve for Heated Water Series VCB Multipurpose Valve for Heated Water Direct Operated Port Solenoid Valve for Heated Water Series VCB Improved durability

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11 Blow Gun RoHS How to Order VMG W Blow gun Standard type Series Resin body lever type W BU Piping entry Bottom Top Body color White ark blue Symbol Nil 3 4 3 3 4 3 3 33 34 Male High efficiency Low noise

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8 G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products. Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures, temperatures, etc.,

More information

Coolant valve. SGC/SGH Series

Coolant valve. SGC/SGH Series Doc. no. PRODUCT NAME Coolant valve MODEL / Series / Product Number SGC/SGH Series Contents Safety Instructions ------------------------------------------------------------------------------------- 2,3

More information

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W)

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W) igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type 31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications

More information

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2.

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2. Series port direct acting solenoid valve : Open when energized, close when energized NRL PURPOS VLV SRIS iscrete valve irect acting poppet structure Port size : Rc/, Rc/, Rc/, Rc/ JIS symbol / (normally

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

General purpose direct acting 2, 3 port solenoid valve

General purpose direct acting 2, 3 port solenoid valve eneral purpose direct acting, 3 port solenoid valve (eneral purpose valve) eneral purpose Direct acting, 3 port solenoid valve / Pilot operated/pilot kick type port solenoid valve P/D/PK/DK Page 9 9 P/

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

Pilot Operated 2 Port Solenoid Valve

Pilot Operated 2 Port Solenoid Valve CT.EUS0-9 -UK Pilot Operated Port Solenoid Valve For Water, Oil, ir Reduction of power consumption (DC specification) 6 W.5 W/5.5 W (VXD0 to 50) W W (VXD0).5 W 0.5 W ew VX D D D Series VXD// Solenoid valves

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B G31/41 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol G31/41: Universal

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8 iscrete direct acting 3 port solenoid valve (general purpose valve) 33/43 Series pressurization type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol 33/43: pressurization

More information

Series VC Direct Operated 2 Port Solenoid Valve for Oil Series VCL

Series VC Direct Operated 2 Port Solenoid Valve for Oil Series VCL T.S0-8 Series V irect Operated Port Solenoid Valve for Oil Series VL Multipurpose Valve for Oil irect Operated Port Solenoid Valve for Oil Series VL Kerosene, uel oil class (fuel oil ), Silicone oil, Machine

More information

Space saving, compact model available

Space saving, compact model available Compact Type High Purity ir Operated Chemical Liquid Valve Series RoHS LV Space saving, compact model available Compact type model is introduced as a new series to complement current series with integrated

More information

VNA VNB SGC SGH VNC VNH VND VCC

VNA VNB SGC SGH VNC VNH VND VCC Steam Valve VN Series Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Series AN05 to 40 RoHS

Series AN05 to 40 RoHS ompact Resin Type/Male Thread Series N05 to 40 N 02 05 15 30 40 Thread type M thread Nil R N NPT Thread connection port size pplicable model M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 N05 N N15/ N30 N40 Max.

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting S Series Push-lock Type Reduces labor time! Easy to use Easy to lock Unlock Push-lock type Lock Improved tube insertion/removal Max. Insertion force: 30% (8 N) reduction

More information

Discrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type

Discrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type N Series Discrete air operated port valve (compact cylinder valve) N* Series N (normally closed) type, NO (normally open) type, double acting type Port size: Rc/, Rc/ Working fluid: air, water, gas JIS

More information

Mechanical Style Pressure Switch. Specifications

Mechanical Style Pressure Switch. Specifications or details about certified products conforming to international standards, visit us at www.smcworld.com. Mechanical Style Pressure Switch Series IS1000 Long service life: 5 million cycles IS1000-01 IS1000-01-X202

More information

2/3 Port Valve for Various Fluids Control

2/3 Port Valve for Various Fluids Control Equipment for Fluid Control 2/ Port Valve for Various Fluids Control 2/ Port Solenoid/ir Operaed Valve for Various Fluids Control (For Water/ir/Oil/Gas/Vacuum/Steam) 2/ Port Solenoid Valve Direct operated

More information

Series AN05 to 40 RoHS

Series AN05 to 40 RoHS Silencer Compact Resin Type/Male Thread N0 to 40 RoHS How to Order N 0 Body size Specifications 0 0 30 40 Thread type M thread Nil R N NPT Thread connection port size pplicable model M 0 0 03 04 M x 0.8

More information

High Purity Chemical Valve Compact Type. Space saving, compact type is available. Piping from 4 directions are possible.

High Purity Chemical Valve Compact Type. Space saving, compact type is available. Piping from 4 directions are possible. High Purity Chemical Valve Compact Type Series Space saving, compact type is available. Compact type is introduced as a new series to complement conventional Series with integral fittings. Select a series

More information

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)* 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air

More information

PVC Quick Drain Valve

PVC Quick Drain Valve PVC Quick Drain Valve LVW Series Complies to JIS standard for polyvinyl chloride piping (JIS K 6742) Applicable fluids: Deionized water, Chemical liquids Application Example Cleaning Equipment Process

More information

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air CAT.ES0- A Direct Operated Port Solenoid Valve For Water, Oil, Steam, Air New Series VX// Reduction of power consumption ( specification) W. W W W. W 0. W Low power consumption type: 0. W (Held at V) New

More information

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator Oil Filter FH150 Series RoHS ompact and lightweight The compact and lightweight design employs an aluminum alloy cover. Easy maintenance The element slides into place, making it easy to install and remove.

More information

Low Torque Rotary Joint

Low Torque Rotary Joint Low Torque Rotary Joint MQR Series Metal Seal Type Long service life billion rotations MQR : billion rotations MQR : 0. billion rotations MQR : 0. billion rotations MQR8 : 0. billion rotations MQR: 0.

More information

Direct Operated 3 Port Solenoid Valve

Direct Operated 3 Port Solenoid Valve CT.EUS06 UK Direct Operated Port Solenoid Valve For Water, Oil, Steam, ir Reduction of power consumption (DC specification) 6 W.5 W 8 W W.5 W W New VX Series VX// Improvement of corrosion resistance Special

More information

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam. Steam Valve Series VN Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable

More information

For Pneumatic Piping/Fittings & Tubing Prior to Use

For Pneumatic Piping/Fittings & Tubing Prior to Use For Pneumatic Piping/Fittings & Tubing Prior to Use Fittings with Sealant Seal material (fluororesin) is coated on the thread part to the proper thickness and within the proper coating range, which reduces

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Normally Closed Type High Vacuum Straight Solenoid Valve. How to Order XSA S 5 G. Fitting size. Fitting Type

Normally Closed Type High Vacuum Straight Solenoid Valve. How to Order XSA S 5 G. Fitting size. Fitting Type Series XS Normally losed Type igh Vacuum Straight Solenoid Valve ow to Order [Option] Normally closed high vacuum straight solenoid valve XS 1 1 S Solenoid size 1 No.1 No. No. 1 Orifice symbol ø ø ø4.

More information

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. an remove odor and gas ingredients

More information

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description ir Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. : 1/4 to 1 JIS symbol Specifications FW4000-W FW8000-W Working fluid ompressed air Max. working pressure MPa 1.0

More information

HN B G1/US B G2/US B G3

HN B G1/US B G2/US B G3 HN B G/US B G/US B G Compact direct acting, port solenoid valve air, water,, low vacuum (. x 0 Pa (abs)) CONTENTS Safety precautions port solenoid valve HNB NC (normally closed) type USB NC (normally closed)

More information

How to Order. Body size

How to Order. Body size Standard Type Series N 00 Over 30 db () noise reduction Low back pressure Compact and easy mounting How to Order N 400 04 Body size 200 300 400 500 600 700 800 900 Thread type Symbol Type Nil R N NPT Symbol

More information

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C Direct acting port solenoid valve, manifold and actuator (general purpose valve) NO (normally closed) type Common supply type (port C pressurization) Manifold circuit structure Common specifications B

More information

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type Pilot kick type 2 port solenoid valve for dry air (general purpose valve) DK11-Z Series NC (normally closed) type Port size: Rc1/4 to Rc1 Diaphragm structure JIS symbol NC (normally closed) type OUT IN

More information

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview HV/HVL For vacuum, inert gas, air, nitrogen HN/G US/G F/G Overview dvanced technology, such as stability in the leak amount (vacuum holding force) and increased seal life, is required when the degree of

More information

Precision Clean Regulator

Precision Clean Regulator Precision Clean Regulator Series AR45 AMR ARM -A VY AP00 High precision, low flow consumption stainless steel regulator 869 Precision Clean Regulator Series High precision, low flow consumption stainless

More information

Rotary Actuators Precautions 1 Be sure to read this before handling.

Rotary Actuators Precautions 1 Be sure to read this before handling. Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures or temperatures, etc.,

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

Series LVQ. Constructed without screws. Air Operated Chemical Valve Non-Metallic Exterior. Space Saving Type

Series LVQ. Constructed without screws. Air Operated Chemical Valve Non-Metallic Exterior. Space Saving Type ir Operated hemical alve on-etallic Exterior Series LQ onstructed without screws on-metallic construction without using metal screws to fasten the body of the actuator. ody section Integral fitting construction

More information

Technical information for LFU20-Z07-3A-X2

Technical information for LFU20-Z07-3A-X2 Technical information for LFU20-Z07-3A-X2 Ultrasonic flow sensor and flow controller Applications: closed-loop flow control. Also requires fluid regulator (separate part) Ultrasonic flow sensor IN18796_LFU

More information

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA Pilot Operated Port Solenoid Valve VXP//3 Series For ir, as,, Water and Oil Variations.O..C. Wide variations of combination. ble to control a wide variety of fluids. Valve can be matched to particular

More information

Low Maintenance Filter

Low Maintenance Filter Low Maintenance Filter FN/FN Series No more element replacement! Our unique element construction with back-flushing capability The element of the filter is constructed of a series of grooved filter plates

More information

Hydraulic Filters. Element (µm) nominal filtration. Port size. Micromesh 74, 105, 149 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 3 1/2, 4

Hydraulic Filters. Element (µm) nominal filtration. Port size. Micromesh 74, 105, 149 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 3 1/2, 4 Hydraulic Filters Series Series Operating pressure Port size (µm) nominal filtration Accessory (Option) Page Vertical Suction Filter Series FHIA Suction Filter with ase Series FH Suction Guard Series FHG

More information

Low Torque Rotary Joint

Low Torque Rotary Joint Low Torque Rotary Joint Series MQR Metal Seal Type K Long service life billion rotations MQR : billion rotations MQR : 0. billion rotations MQR : 0. billion rotations MQR8 : 0. billion rotations MQR: 0.

More information

AV2000-A/3000-A/4000-A/5000-A

AV2000-A/3000-A/4000-A/5000-A Soft Start-up Valve Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply Power consumption: 0.35 W * At 12/24 VDC

More information

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 3000 SERIES Bronze, Normally Closed, Direct Lift Installation Instructions WARNING: These instructions

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation

Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Pilot Operated -Port Solenoid Valve/ Zero Pressure Differential Operation For Steam Compact and Lightweight New Enclosure: IP65 Low-noise construction Operation noise is reduced due to full wave rectifier

More information