Discrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type

Size: px
Start display at page:

Download "Discrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type"

Transcription

1 N Series Discrete air operated port valve (compact cylinder valve) N* Series N (normally closed) type, NO (normally open) type, double acting type Port size: Rc/, Rc/ Working fluid: air, water, gas JIS symbol (*) N (normally closed) type NO (normally open) type *: If port is normally pressurized, refer to the individual precautions. Specifications Item N- N-0 N- N-0 N- N-0 ctuation Working fluid Fluid viscosity mm /s Working pressure range MPa Withstanding pressure (water) MPa Fluid temperature mbient temperature N (normally closed) type NO (normally open) type ir, gas, water (*) 500 or less 0 to to 60 (no freezing) (*) -0 to 60 Valve seat leakage cm /min. 0. or less (pneumatic pressure) Port size Rc/ Rc/ Rc/ Rc/ Rc/ Rc/ Orifice v flow factor [dm /(s bar)] b Weight mm kg Mounting attitude Free Pilot air pressure MPa 0.5 to 0. (*) Pilot port size Rc/ *: Refer to the working fluid check list in page 6 of the Introduction. *: This applies to both sealants, nitrile and fluoro rubbers. *: Refer to page for the pilot air pressure for the NO and double acting types. *: Effective sectional area S and sonic conductance are converted as S 5.0. How to order N Model no. ctuation Port size <Example of model number> N-- Model no.: N ody/sealant combination * D Other options ctuation : N (normally closed) type Port size : Rc/ ody/sealant combination : ody - brass, sealant - fluoro rubber D Other options : Mounting plate Symbol Descriptions ctuation Port size 0 N (normally closed) type NO (normally open) type Rc/ Rc/ ody/sealant combination lank D E Option D Other options lank Std. ody rass rass Stainless steel Stainless steel No options Mounting plate Sealant Fluoro rubber Fluoro rubber Note on model no. selection *: For standard, is blank. However, to select other options in D, indicate 0 for.

2 N Series Internal structure and parts list N HN/G US/G F/G FG/G 5 FV 6 FW/G FH Dimensions N*-/0 9 0 Port (Page 96) Port No. Parts name ylinder cover Spring Piston 5 PSD packing seal 6 O ring O ring M packing seal 9 O ring 0 daptor Valving element ody ( ) shows options. Material D SWP PPS NR NR NR (FKM) NR (FKM) NR (FKM) 60 (SUS0) NR (FKM) (SS) Mounting plate N*-/0-* luminum die casting Piano wire Polyphenylene sulfide rass (stainless steel) rass (stainless steel casting) FL G P/ D PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G M/G 5 -Rc/ ø6 -ø6 Other G.P. systems PD/FD/ PJ VE/ VSE PE/ PD Medical analysis ustom order -Rc/ or Rc/ 0 KD ompact cylinder valve ir operated port valve -M5 depth 5

3 N*V Series Discrete air operated port valve (compact cylinder valve) N*V Series N (normally closed) type, NO (normally open) type, double acting type Port size: Rc/, Rc/ Working fluid: low vacuum JIS symbol N (normally closed) type NO (normally open) type ommon specifications Item NV- NV-0 NV- NV-0 NV- NV-0 ctuation Working fluid N (normally closed) type NO (normally open) type Low vacuum (air, water) (*) Fluid viscosity mm /s Working pressure range Pa (abs) Withstanding pressure (water) MPa Fluid temperature mbient temperature Valve seat leakage Pa m /s He Port size Orifice mm [dm /(s bar)] b Weight kg Mounting attitude Pilot air pressure MPa Pilot port size Rc/ 0.5 to 0. Rc/ 500 or less. x 0 to x to 60 (no freezing) (*) -0 to 60. x 0 - or less Rc/ Free Rc/ *: Refer to the working fluid check list in page 6 of the Introduction. *: This applies to both sealants, nitrile and fluoro rubbers. *: Refer to page for the pilot air pressure for the NO and double acting types. *: Effective sectional area S and sonic conductance are converted as S 5.0. Rc/ (*) Rc/ Rc/ How to order N V 0 Model no. ctuation Working fluid (vacuum) Port size <Example of model number> NV--0 Model no.: N ody/sealant combination * D Other options Symbol ctuation Port size 0 Option Descriptions N (normally closed) type NO (normally open) type Rc/ Rc/ ody/sealant combination lank D E D Other options lank Std. ody rass rass Stainless steel Stainless steel No options Mounting plate Sealant Fluoro rubber Fluoro rubber ctuation : N (normally closed) type Port size : Rc/ ody/sealant combination : ody - brass, sealant - nitrile rubber D Other options : Mounting plate Note on model no. selection 6 *: For standard, is blank. However, to select other options in D, indicate 0 for.

4 N*V Series Internal structure and parts list NV HN/G US/G 5 F/G FG/G FV FW/G Port Dimensions N*V-/0 (Page 96) Port No. Parts name ylinder cover Spring Piston 5 PSD packing seal 6 O ring O ring M packing seal 9 O ring 0 daptor Valving element ody ( ) shows options. Material D SWP PPS NR NR NR (FKM) NR (FKM) NR (FKM) 60 (SUS0) NR (FKM) (SS) Mounting plate N*V-/0-* luminum die casting Piano wire Polyphenylene sulfide rass (stainless steel) rass (stainless steel casting) FH FL G P/ D PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G ø6 -ø6 M/G Other G.P. systems PD/FD/ PJ VE/ VSE PE/ PD -Rc/ -Rc/ or Rc/ 0 KD 5 Medical analysis ustom order ompact cylinder valve ir operated port valve -M5 depth

5 GN* Series ir operated port valve, manifold (compact cylinder valve) GN* Series N (normally closed) type, NO (normally open) type, double acting type Port size: Rc/, Rc/ Working fluid: air, gas, water JIS symbol ommon supply type (port pressurization) N (normally closed) type NO (normally open) type Individual supply type (port pressurization) N (normally closed) type NO (normally open) type Specifications Item GN-/5 GN-/5 GN-/5 ctuation Working fluid Fluid viscosity mm /s Working pressure range MPa Withstanding pressure (water) MPa Fluid temperature mbient temperature N (normally closed) type NO (normally open) type ir, gas, water (*) 500 or less 0 to to 60 (no freezing) (*) -0 to 60 Valve seat leakage cm /min. 0. or less (pneumatic pressure) Orifice v flow factor [dm /(s bar)] b mm Mounting attitude Free Pilot air pressure MPa 0.5 to 0. (*) Pilot port size Rc/ *: Refer to the working fluid check list in page 6 of the Introduction. *: This applies to both sealants, nitrile and fluoro rubbers. *: Refer to page for the pilot air pressure for the NO and double acting types. *: Effective sectional area S and sonic conductance are converted as S 5.0. How to order GN 5 Model no. ctuation ir supply Station no. <Example of model number> GN--5- Model no.: GN D Sub-plate/ body/sealant combination Symbol ctuation Option Descriptions N (normally closed) type NO (normally open) type ir supply 5 ommon supply type Individual supply type Station no. to 0 0 stations to 0 stations Only actuator D Sub-plate/body/sealant combination lank D E Std. Sub-plate rass rass Stainless steel Stainless steel luminum luminum ody Polypropylene Polypropylene Stainless steel Stainless steel Polypropylene Polypropylene Sealant Fluoro rubber Fluoro rubber Fluoro rubber Remarks Water Solvents ir, gas ctuation : N (normally closed) type ir supply : ommon supply type Station no. : 5 stations D Sub-plate/body/sealant combination : Sub-plate - brass, body - polypropylene, sealant - fluoro rubber

6 GN* Series Internal structure and parts list GN HN/G US/G Figure shows GN-. F/G FG/G FV FW/G FH FL G P/ D PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G M/G Other G.P. systems No. 5 6 Parts name ylinder cover Spring Piston PSD packing seal O ring O ring ( ) shows options. Material No. Parts name Material D luminum die casting M packing seal NR (FKM) SWP Piano wire 9 O ring NR (FKM) 0 daptor 60 (SUS0) PPS NR Polyphenylene sulfide Valving element ody NR (FKM) PP (SUS0) NR Sub-plate 60 ( SUS0 606 ) NR (FKM) Mounting plate SP rass (stainless steel) Polypropylene (stainless steel) rass (stainless steel, aluminum) Steel PD/FD/ PJ VE/ VSE PE/ PD Medical analysis ustom order ompact cylinder valve ir operated port valve 9

7 GN* Series Dimensions: ctuator (Page 96) ommon supply type GN//--0 How to mount actuator 5 -Rc/ Port (IN side) 9 pitch or more ±0. -M screw depth 6 or more 9.5 (5).5 (50) (60) ±0. ±0. Port (OUT side) ±0. ø depth ø.5 or less -M ø (6).5 (ø) Individual supply type GN//-5-0 How to mount actuator 5 -Rc/ ±0. Port (OUT side) 9 pitch or more -M screw depth 6 or more ø depth (5).5 (50) (60) Port (IN side) ±0. -ø.5 or less -M (ø).5 (6) ±0. ±0. ø Note : Dimensions shown in ( ) are for the stainless steel option. Note : To protect the product, the product is delivered with a plate at the bottom. Remove this plate before starting use. 90

8 GN* Series Dimensions: Manifold (Page 96) GN//- 5- to 0 (brass sub-plate) (stainless steel sub-plate) HN/G 5 -Rc/ (Port ) US/G F/G FG/G (69).5 ().5 (9) Rc/ (Port ) FV FW/G FH FL G 0 P/ D Dimensions shown in ( 9 -Rc/ t 0 GN//- 5- to 0 (aluminum sub-plate) 5 ) are for the stainless steel sub-plate. -Rc/ (Port ) PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G -Rc/ M/G Rc/ (Port ) DD t 0 Other G.P. systems PD/FD/ PJ VE/ VSE PE/ PD Medical analysis 0 ustom order Station no DD Manifold structure * Station no. stations x stations x stations x 9 5 stations x 0 stations x DD 60 Manifold structure * 5 stations + stations 5 stations + stations stations x 5 stations x ompact cylinder valve ir operated port valve *: manifold is configured by combining -, - and 5-station modules. *: onsult with KD about more than 0 stations manifold. 9

9 GN*V Series ir operated port valve, manifold (compact cylinder valve) GN*V Series N (normally closed) type, NO (normally open) type, double acting type Port size: Rc/, Rc/ Working fluid: low vacuum JIS symbol ommon supply type (port pressurization) N (normally closed) type NO (normally open) type Individual supply type (port pressurization) N (normally closed) type NO (normally open) type Specifications Item ctuation N (normally closed) type Working fluid Fluid viscosity mm /s Working pressure range Pa (abs) Withstanding pressure (water) MPa Fluid temperature mbient temperature Valve seat leakage Pa m /s He Orifice mm [dm /(s bar)] b Mounting attitude Pilot air pressure MPa 0.5 to 0. Pilot port size GNV-/5 GNV-/5 GNV-/5 NO (normally open) type Low vacuum (air, water) (*) 500 or less. x 0 to x to 60 (no freezing) (*) -0 to 60. x 0 - or less. 0. Free Rc/ *: Refer to the working fluid check list in page 6 of the Introduction. *: This applies to both sealants, nitrile and fluoro rubbers. *: Refer to page for the pilot air pressure for the NO and double acting types. *: Effective sectional area S and sonic conductance are converted as S 5.0. How to order GN V 5 (*) Model no. Working fluid (vacuum) ctuation ir supply <Example of model number> GNV--5- Model no.: GN D Station no. D Sub-plate/ body/sealant combination Symbol ctuation Option Descriptions N (normally closed) type NO (normally open) type ir supply 5 Port vacuum pump side Port vacuum pump side Station no. to 0 0 stations to 0 stations Only actuator ctuation : N (normally closed) type ir supply : Port vacuum pump side Station no. : 5 stations Sub-plate/body/sealant combination : Sub-plate - aluminum, body - polypropylene, sealant - nitrile rubber D Sub-plate/body/sealant combination Sub-plate ody Sealant Remarks lank Std. rass Polypropylene Water, vacuum rass Polypropylene Fluoro rubber Solvents D Stainless steel Stainless steel Vacuum E Stainless steel Stainless steel Fluoro rubber luminum Polypropylene ir, luminum Polypropylene Fluoro rubber vacuum 9

10 GN*V Series Internal structure and parts list GNV HN/G Figure shows GNV-. US/G F/G FG/G FV FW/G FH FL G P/ D PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G M/G No. 5 6 Parts name ylinder cover Spring Piston PSD packing seal O ring O ring ( ) shows options. Material No. Parts name Material D luminum die casting M packing seal NR (FKM) SWP Piano wire 9 O ring NR (FKM) 0 daptor 60 (SUS0) PPS NR NR Polyphenylene sulfide Valving element ody Sub-plate NR (FKM) PP (SUS0) 60 ( SUS0 606 ) NR (FKM) Mounting plate SP rass (stainless steel) Polypropylene (stainless steel) rass (stainless steel, aluminum) Steel Other G.P. systems PD/FD/ PJ VE/ VSE PE/ PD Medical analysis ustom order ompact cylinder valve ir operated port valve 9

11 GN*V Series Dimensions: ctuator (Page 96) Port vacuum pump side GN*V--0 How to mount actuator 5 -Rc/ Port (IN side) 9 pitch or more ±0. -M screw depth 6 or more 9.5 (5).5 (50) (60) ±0. ±0. Port (OUT side) ±0. ø depth ø.5 or less -M ø (6).5 (ø) Port vacuum pump side GN*V-5-0 How to mount actuator 5 -Rc/ ±0. Port (OUT side) 9 pitch or more -M screw depth 6 or more ø depth (5).5 (50) (60) Port (IN side) ±0. -ø.5 or less -M (ø).5 (6) ±0. ±0. ø Note : Dimensions shown in ( ) are for the stainless steel option. Note : To protect the product, the product is delivered with a plate at the bottom. Remove this plate before starting use. 9

12 GN*V Series Dimensions: Manifold (Page 96) GN*V- 5- to 0 (brass sub-plate) (stainless steel sub-plate) HN/G 5 -Rc/ (Port ) US/G F/G FG/G (69).5 ().5 (9) 9 Rc/ (Port ) -Rc/ t 0 FV FW/G FH FL G 5 0 Dimensions shown in ( GN*V- 5- to 0 (aluminum sub-plate) ) are for the stainless steel sub-plate. -Rc/ (Port ) P/ D PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G -Rc/ M/G Rc/ (Port ) DD t 0 Other G.P. systems PD/FD/ PJ VE/ VSE PE/ PD Medical analysis ustom order Station no. DD Manifold structure * Station no. DD Manifold structure * stations x stations x stations x 5 stations x stations x stations + stations 5 stations + stations stations x 5 stations x *: manifold is configured by combining -, - and 5-station modules. *: onsult with KD about more than 0 stations manifold. ompact cylinder valve ir operated port valve 95

13 S/SV/N Series Electronic atalog file list ir operated port valve (cylinder valve) ir operated type S (pages to 6) Model no. S**-(0)-* S**-5-* S**-0-* S**-5-* S**--* S**-F-* S**-0-* S**-0F-* S**-50-* S**-50F-* S**-65F-0() S**-0F-0() ccessory (mounting plate) Folder name S DF Filename sab (0)a sab 5a sab 0a sab 5a sab a sab f sab 0a sab 0f sab 50a sab 50f sab 65f_0(b) sab 0f_0(b) sab_f Electronic atalog file list is applied to "D DT 006". MIRO DM Filename (GROUP: D, USER: STDLI) KD-S**-(0)-* KD-S**-5-* KD-S**-0-* KD-S**-5-* KD-S**--* KD-S**-F-* KD-S**-0-* KD-S**-0F-* KD-S**-50-* KD-S**-50F-* KD-S**-65F-0() KD-S**-0F-0() KD-S-F Solenoid valve mounted type SV (pages 66 to ) Model no. SV**-(0)-* SV**-5-* SV**-0-* SV**-5-* SV**--* SV**-F-* SV**-0-* SV**-0F-* SV**-50-* SV**-50F-* SV**-65F-0() SV**-0F-0() ccessory (DIN terminal box, DIN terminal box + light, T type terminal box, T type terminal box + light, mounting plate) Folder name SV DF Filename svb (0)a svb 5a svb 0a svb 5a svb a svb f svb 0a svb 0f svb 50a svb 50f svb 65f_0(b) svb 0f_0(b) svb_f MIRO DM Filename (GROUP: D, USER: STDLI) KD-SV**-(0)-* KD-SV**-5-* KD-SV**-0-* KD-SV**-5-* KD-SV**--* KD-SV**-F-* KD-SV**-0-* KD-SV**-0F-* KD-SV**-50-* KD-SV**-50F-* KD-SV**-65F-0() KD-SV**-0F-0() KD-SV-F ompact type (pages 5 to 95) N*-(0)-* GN*-*(-) GN*-*-() GN*-*-D(E) GN*--0(-) GN*--0-D(E) GN*-5-0(-) GN*-5-0-D(E) Model no. Folder name N GN DF Filename nab 0 gnab b_ gnab gnab d_e_ gnab 0 b_ gnab 0_d_e_ gnab 5_0 b_ gnab 5_0_d_e_ MIRO DM Filename (GROUP: D, USER: STDLI) KD-N*-(0)-* KD-GN*-*(-) KD-GN*-*-() KD-GN*-*-D(E) KD-GN*--0(-) KD-GN*--0-D(E) KD-GN*-5-0(-) KD-GN*-5-0-D(E) 96

14 S/SV/N (ylinder valve) ir operated port valve For water, air, gas, low vacuum, steam HN/G US/G F/G Overview In addition to water, air, gas, low vacuum and steam, high viscosity fluids and powder mixed fluids are also available. Using the external pilot air, this air operated cylinder valve is driven with the cylinder. ir operated type S, solenoid valve mounted type SV, compact type N and manifold GN Series are available to meet needs of controlling various fluids. Features Wide variation Rc/ to 0 flange are available in accordance with port size. vailable in flammable environment actuations types: N (normally closed), NO (normally open) and double acting are available. ylinder driven with external pilot air ensures certain operations. ONTENTS Series variation Safety precautions 0 Product introduction ir operated type (port size Rc/ to Rc, to 0 flange) Water, liquid S*W 6 ir S* 50 Low vacuum S*V 5 Steam, water, air S*S 5 Solenoid valve mounted type (port size Rc/ to Rc, to 0 flange) Water, liquid SV*W 6 ir SV* 0 Low vacuum SV*V Steam, water, air SV*S ompact air operated type (port size Rc/, Rc/) Discrete ir, gas, water N* Low vacuum, air, water N*V 6 Manifold ir, gas, water GN* Low vacuum, air, water GN*V 9 Electronic atalog file list 96 lways read the precautions in the Introduction and page 0 before starting use. FG/G FV FW/G FH FL G P/ D PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G M/G Other G.P. systems PD/FD/ PJ VE/ VSE PE/ PD Medical analysis ustom order ylinder valve ir operated port valve

15 Series variation ir operated port valve (cylinder valve) ategory Model No. of port N ctuation NO Double acting operation Rc/ Rc/ Rc/ ir operated type Water, liquid S*W ir, gas S* Low vacuum S*V ompact cylinder valve ylinder valve Solenoid valve mounted type ir operated type ir operated type manifold Steam, water, air S*S Water, liquid SV*W ir, gas SV* Low vacuum SV*V Steam, water, air SV*S General purpose N* Low vacuum N*V General purpose GN* Low vacuum GN*V port Port Port Port Port

16 S/SV/N Series Series variation Rc/ Port size Rc Rc / 0 Rc / flange flange Rc 50 flange 65 flange 0 flange Page HN/G US/G F/G 6 FG/G 50 FV FW/G 5 FH FL 5 G 6 0 P/ D PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G M/G 6 Other G.P. systems PD/FD/ PJ VE/ VSE PE/ PD 9 Medical analysis ustom order ylinder valve ir operated port valve 9

17 Safety precautions lways read this section before starting use. ir operated port valve (cylinder valve) Design & Selection. Safety Designing UTION Leakage current from other fluid control components When operating the solenoid valve with a programmable controller, etc., check that the output leakage current from the programmable controller is within the following specifications. Failure to observe this could lead to malfunctions. R circuit Triode switch Programmable controller side R. Working Fluid WRNING Leakage current Solenoid valve 00 V: m or less 00 V:.5 m or less VD: m or less must be maintained. Working fluid () Do not use this product for fluids other than applicable fluids in catalog specifications. () efore starting use, check the compatibility between the product and working fluid with the working fluid check list (page 6 in Introduction). () The durability of the rod packing seal (M packing seal) drops if working fluid quality is poor and contains powder, sludge or foreign matter. If rod packing sealing is poor, working fluid could leak into the cylinder and flow back into pilot air piping, damaging the devices in the air circuit. onduct regular maintenance or take appropriate measures. Special purpose grease For cylinder valve, grease is applied to the piston rod sealing sections. When using special fluids, specify the type of grease. (Example) Oxygen: fluorine grease Medium vacuum: silicone grease Fluids for foods: vaseline Dry air for painting: vaseline Fluid temperature Use within the fluid temperature range. UTION External pilot air () Drainage measures - ompressed air contains high levels of drainage (water, oxidized oil, tar, foreign matter) that can significantly reduce the reliability of pneumatic components. s measures against drain, improve air quality by dehumidifying with an after cooler or dryer, removing foreign matter with a filter, and removing tar with a tar removal filter, etc. () Pre-lubrication - This series is pre-lubricated, so no lubricator is required. However, once lubrication has been started, it must be continued so that the lubricant is not used up. For lubrication, use the turbine oil lass ISO VG (#90) or equivalent. () Filter - Install a filter with a 5 µm or less filter element.. Working Environment WRNING SV Series cannot be used in an explosive gas atmosphere. When using in an explosive gas atmosphere, change to the S Series, and provide a separate explosion proof solenoid valve on the pilot air circuit. If there are high levels of dust in the area, install a downward-facing silencer or elbow joint on the exhaust port so that dust does not enter. When using in a place where water splashes on the valve, take appropriate measures to protect it. Installation & djustment. Piping UTION Do not mistake the supply port when piping to the product. Do not pipe using the solenoid valve section. There is a risk of damage. (For solenoid valve mounted type) 0

18 heck the pilot operation side supply port when piping the GN Series. Model no. GN/GNV GN/GNV GN/GNV Model no. N-/0 N-/0 N-/0 NV-/0 NV-/0 NV-/0 SW SW SW S S S SV SV SV SS SS SS SVW SVW SV SV SVV SVV SVS SVS Unit side supply port or or or or or When Using Pilot operation side supply port and and and and and and P P P P P P P P Note ) With N -/0, when both ports and are pressurized, connect port to the normally pressurized side. If port is connected to the normally pressurized side, the durability could drop further than when port is connected. Note ) With the S V or SV V side port, connect the chamber (vacuum holding side) to port. hamber Note that when using for vacuum break, etc., set the pressurized port to port. (Example of improper use) Sealed Pilot operation side supply port and When piping the S or SV Series, pay attention to the supply ports on the unit and pilot operation sides. Vacuum pump When operating a hydraulic cylinder with a cylinder valve for water, if the valve's port is piped to the cylinder, pressure in the port and piping rises and excessive pressure is applied on the valve body, leading to damage. In this case, pipe the valve's port to the cylinder side. V.P (Example of proper use) Nominal pipe diameter Rc/ S/SV/N Series When using the valve for steam, external leaks could occur depending on fluid properties. Install a steam trap by inclining piping, etc., and remove drainage to prevent the inside of the pipe from rusting. Strainer Steam trap S Refer to the table below for tightening torque of the pilot air piping. Recommended pipe tightening torque (N m) to 9 If a manifold is used on the S Series operation valve, exhaust pressure could be led in from other valves, which causes malfunctions such as momentary opening of the S. When using a manifold, use a valve with a built-in "check valve". Similar problems could occur if exhaust is led in from the SV Series exhaust (R) port, so when piping the exhaust (R) port, do not connect with other exhaust circuits. check valve is built into KD pilot operated /5 port valve G Series. Example of pneumatic pressure that could misoperate Exhaust pressure Misoperation of air operated port valve Pneumatics system using G Series Prevention of misoperation of air operated port valve Exhaust pressure Individual precautions Exhaust pressure Exhaust pressure Exhaust pressure heck valve * Note that the cylinder cannot be operated manually even in an nonpressurized state. HN/G US/G F/G FG/G FV FW/G FH FL G P/ D PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G M/G Other G.P. systems PD/FD/ PJ VE/ VSE PE/ PD Medical analysis ustom order ylinder valve ir operated port valve Sealed

19 S/SV/N Series Installation & djustment. Wiring UTION When using an explosion proof solenoid valve, follow the Recommended Practices for Explosion-protected Electrical Installations in General Industries when wiring. () oil direction can be changed 0. To reverse the electrical connection direction, rotate only the coil. Do not lose internal parts when removing the coil. Wiring of solenoid valve mounted type () Refer to connections in pages 5 to 55 in the Introduction when wiring to a DIN terminal box or T type terminal box. () The size of the screw for the junction box outlets of the DIN terminal box can be changed from Pg9 to G/ using the optional connector below. 5 6 Hexagon head Pg9 G / Model no.: VS-ONNETOR-F-096 During Use & Maintenance. Maintenance & Inspection Pilot air pressure Use pilot air pressure in accordance with the specifications. Set the pilot pressure for the S/SV Series NO type and double acting type as shown in the graph below. sealing fault could occur if pressure is set less than the range shown in the graph at right. The N type should be selected when the pilot air cannot be controlled. N V Series/GN V Series 0. Pilot air pressure (MPa) Pilot air set pressure range Working pressure (MPa) N V Series/GN V Series (MPa) Working pressure (MPa) Pilot air pressure UTION Pilot air set pressure range S W V Series/SV V Series W Pilot air 0.5 set pressure range (MPa) Working pressure (MPa) Pilot air pressure S S Series/SVS Series Pilot air pressure (MPa) Pilot air set pressure range Working pressure (MPa). ssembling & Disassembling WRNING spring is used in the cylinder cover. When disassembling this type, the spring could pop out and cause injuries, so take care. The N (normally closed) type has a snap ring to prevent the spring from popping out. Do not remove the snap ring.

20 ssembling pilot solenoid valve (for solenoid valve mounted type) If the pilot solenoid valve has been disassembled, assemble it as follows. () oil side Disassembling Loosen the cross headed pan head machine screw, and lift up the coil assembly. The outer spring, plunger assembly and O ring can be removed. Reassembling Set the parts in the sequence of the O ring, plunger assembly, outer spring and coil assembly. Tighten the cross headed pan head machine screw with a torque of 0. to. N m. () over side Disassembling Loosen the flat headed cross cut screw, and remove the cover. The valving element spring, valving element guide assembly and O ring can be removed. Reassembling Set the parts in the sequence of the O ring, valving element guide assembly, valving element spring and cover. Tighten the flat headed cross cut screw with a torque of 0. to. N m. Note : Do not lose the components such as springs during disassembly. Note : The coil assembly direction can be changed 0. Loosen the cross headed pan head machine screw to change the direction. Note : Turbine oil is applied to the plunger as a lubricant. Model no. of pilot solenoid valve (actuator assembly kit) for SV*W/SV*/SV*V * VSE-TUTOR 0 Rated voltage * Indicate the coil option symbol in field *. Model no. of pilot solenoid valve (actuator assembly kit) for SV*S SV-TUTOR- * Rated voltage * Indicate the coil option symbol in field *. Gasket direction (for solenoid valve mounted type) The gasket has an orientation. heck the orientation when reassembling. Gasket S/SV/N Series Individual precautions ross headed pan head machine screw oil assembly O ring ody assembly O ring Valving element guide assembly Valving element spring over Note Outer spring Plunger assembly Flat headed cross cut screw HN/G US/G F/G FG/G FV FW/G FH FL G P/ D PK/ DK For dry air Explosion proof HV/ HVL S/ SV NP/NP/ NVP H/G M/G Other G.P. systems PD/FD/ PJ VE/ VSE PE/ PD Medical analysis ustom order SV* N (normally closed) type Port R SV* NO (normally open) type Port R ylinder valve ir operated port valve

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8 G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications

More information

CVE2/CVSE2 CVE3/CVSE3

CVE2/CVSE2 CVE3/CVSE3 Overview This is a reliable 2, 3 port coolant valve with cylinder drive method. This valve for tool machine cutting oil or coolant control incorporates a metal seal to prevent the entry of cutting chips,

More information

General purpose direct acting 2, 3 port solenoid valve

General purpose direct acting 2, 3 port solenoid valve eneral purpose direct acting, 3 port solenoid valve (eneral purpose valve) eneral purpose Direct acting, 3 port solenoid valve / Pilot operated/pilot kick type port solenoid valve P/D/PK/DK Page 9 9 P/

More information

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview HV/HVL For vacuum, inert gas, air, nitrogen HN/G US/G F/G Overview dvanced technology, such as stability in the leak amount (vacuum holding force) and increased seal life, is required when the degree of

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B G31/41 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol G31/41: Universal

More information

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type Pilot kick type 2 port solenoid valve for dry air (general purpose valve) DK11-Z Series NC (normally closed) type Port size: Rc1/4 to Rc1 Diaphragm structure JIS symbol NC (normally closed) type OUT IN

More information

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B Pilot operated port solenoid valve (general purpose valve) P/P Series NC (normally closed) type, NO (normally open) type Port size: Rc/4 to Rc Piston structure Refer to Ending 7 for more details. JIS symbol

More information

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C Direct acting port solenoid valve, manifold and actuator (general purpose valve) NO (normally closed) type Common supply type (port C pressurization) Manifold circuit structure Common specifications B

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8 iscrete direct acting 3 port solenoid valve (general purpose valve) 33/43 Series pressurization type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol 33/43: pressurization

More information

HN B G1/US B G2/US B G3

HN B G1/US B G2/US B G3 HN B G/US B G/US B G Compact direct acting, port solenoid valve air, water,, low vacuum (. x 0 Pa (abs)) CONTENTS Safety precautions port solenoid valve HNB NC (normally closed) type USB NC (normally closed)

More information

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type 31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications

More information

AB41E4-Z Series. Pressure and explosion proof structure d2g4 (flame-proof grade 2, ignitability G4) NC (normally closed) type. Port size: Rc1/4, Rc3/8

AB41E4-Z Series. Pressure and explosion proof structure d2g4 (flame-proof grade 2, ignitability G4) NC (normally closed) type. Port size: Rc1/4, Rc3/8 Explosion proof type direct acting port solenoid valve for dry air (general purpose valve) B41E4-Z Series Pressure and explosion proof structure dg4 (flame-proof grade, ignitability G4) Port size: Rc1/4,

More information

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description ir Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. : 1/4 to 1 JIS symbol Specifications FW4000-W FW8000-W Working fluid ompressed air Max. working pressure MPa 1.0

More information

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid Metal free, port solenoid valve for chemical liquid MY/MYG Series NC (normally closed) type, universal type Working fluid: water, pure water, chemical liquids Port size: M JIS symbol MY ( port) : NC (normally

More information

Pilot operated 2 port valve for dust collector control (pulsejet valve) Common specifications Air operated type. Solenoid valve mounted type Item OUT

Pilot operated 2 port valve for dust collector control (pulsejet valve) Common specifications Air operated type. Solenoid valve mounted type Item OUT PD3/PDV3 Series Pilot operated 2 port valve for dust collector control (pulsejet valve) PD3/PDV3 Series Air operated type, solenoid valve mounted type Port size: Rc3/4, Rc1, : Rc1 1/2 - : ø48, Rc1 1/2

More information

PD3/PDV3-20A/25A/40A Series

PD3/PDV3-20A/25A/40A Series Pilot operated 2-port valve for dust collector control (Large port size dust collector valve) PD3/PDV3-20A/25A/40A Series Air operated/with solenoid valve Port size: Rc3/4, Rc1, : Rc1 1 /2-: φ48, Rc1 1

More information

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2.

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2. Series port direct acting solenoid valve : Open when energized, close when energized NRL PURPOS VLV SRIS iscrete valve irect acting poppet structure Port size : Rc/, Rc/, Rc/, Rc/ JIS symbol / (normally

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

HMV/HSV. Manual switching valve. 4 port valve

HMV/HSV. Manual switching valve. 4 port valve 4 port valve Overview The and Series manual switching value is 4 port valves incorporating a sliding valve for the main valve. This value is suitable for driving cylinders ø0 to ø0. eatures Low sliding

More information

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam. Steam Valve Series VN Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable

More information

New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series

New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series New roducts 3 ort Solenoid Valve with Spool osition Detection SN Series New roduct Reliable detection of open and close status by spool position detecting. Two safety cut off by modular connection! Main

More information

PDVE4 Series PDVE4 20A 3T AC100V. Explosion proof 2 port solenoid valve for dust collector control (explosion proof pulsejet valve)

PDVE4 Series PDVE4 20A 3T AC100V. Explosion proof 2 port solenoid valve for dust collector control (explosion proof pulsejet valve) Explosion proof port solenoid valve for dust collector control (explosion proof pulsejet valve) PDVE Series Pressure and explosion proof structure dg (flame-proof grade, ignitability G) NC (normally closed)

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

VNA VNB SGC SGH VNC VNH VND VCC

VNA VNB SGC SGH VNC VNH VND VCC Steam Valve VN Series Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator Oil Filter FH150 Series RoHS ompact and lightweight The compact and lightweight design employs an aluminum alloy cover. Easy maintenance The element slides into place, making it easy to install and remove.

More information

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Coolant Valve. VNC Series. Cylinder actuation by pilot air oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating, MNE0 M MN W L/ QV JIS symbol 5 port valve position single solenoid position double solenoid position all ports closed position //R connection position P// connection Common specifications Descriptions

More information

Two Hand Control Valve

Two Hand Control Valve Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram

More information

Series variation. Speed control valve SC* For 2.5 to 450 cylinders. * Refer to page 854 for line type.

Series variation. Speed control valve SC* For 2.5 to 450 cylinders. * Refer to page 854 for line type. Series variation Model / appearance Miniature speed Miniature in out control valve Direct piping / elbow type Model no. SM SM SDM SDM SRM SR SR Port size (Rc or R) S* For. to cylinders pplicable tube O.D.

More information

Free position locking flat and compact cylinder UFCD Series

Free position locking flat and compact cylinder UFCD Series Space-saving cylinder ensures safety during work in power failures or accidents. Free position locking flat and compact cylinder UFCD Series Free position locking flat and compact cylinder UFCD Series

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Design & Selection. Installation & Adjustment

Design & Selection. Installation & Adjustment U SM Series WRNING This product must not be used submerged in water, oil or powder, or where coolant, coolant fluid or swarf, etc., may come in contact. lways incorporate an interlock in the control circuit

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Series variation. Rotary actuator (vane mechanism) RV3* Series. Compact (RV3*1 to RV3*30) : Standard, : Option, : Not available

Series variation. Rotary actuator (vane mechanism) RV3* Series. Compact (RV3*1 to RV3*30) : Standard, : Option, : Not available F J H2 L2 N/ S/F Variation Standard type With valve ngle variable type Series variation ompact ( to ) Model no. RVS RV RVS RV RVS RV RVS2 RV2 RVS RV RVS V W RV V W RVS V W2 RV V W2 RVS V W RV V W RVS RV

More information

2/3 Port Valve for Various Fluids Control

2/3 Port Valve for Various Fluids Control Equipment for Fluid Control 2/ Port Valve for Various Fluids Control 2/ Port Solenoid/ir Operaed Valve for Various Fluids Control (For Water/ir/Oil/Gas/Vacuum/Steam) 2/ Port Solenoid Valve Direct operated

More information

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm M0/MB0 Small pneumatic valve M Overview The M0 and MB0 Series port valve is a 0 mm wide miniature direct-acting poppet valve compatible with system downsizing. variety of types, including discrete and

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment P ir Refrigerating ir Overview ir P is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air

More information

Position locking clamp cylinder. UCAC2 Series. Bore size: ø50, ø63. Double acting single rod type

Position locking clamp cylinder. UCAC2 Series. Bore size: ø50, ø63. Double acting single rod type Position locking clamp cylinder U2 Series : ø50, ø63 XXXXX Series Specifications JIS symbol Descriptions U2 mm ø50 ø63 ctuation Double acting Working fluid ompressed air Max. working pressure MPa 1.0 Min.

More information

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance! New Products Compact Pilot Operated Solenoid Valve for Water FWD Series New Product COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER Lightweight and large flow rate, low power consumption Improved corrosion

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Compact direct acting precision regulator

Compact direct acting precision regulator direct acting precision Components preparation and pressure adjustment / unit CONTENTS Product introduction 6 Safety precautions 62 Discrete (RJB500) 624 Block manifold (MNRJB500) 626 Block configurations

More information

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. an remove odor and gas ingredients

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

Series AN /Series AMC

Series AN /Series AMC s/exhaust Cleaner / Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0- Compact type

More information

Compact / Lightweight 2 Port Solenoid Valve

Compact / Lightweight 2 Port Solenoid Valve ompact / Lightweight 2 Port Solenoid Valve /-XF For ir/water ompact / Lightweight resin body (PPS) Weight: 20 g (-XF) RoHS IP65 mm Power consumption 3 W (Standard) 0.5 W (With power-saving circuit) 48

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Power Valve Precision Regulator

Power Valve Precision Regulator Power Valve Precision Regulator VEX Series High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

King Of Valve Co.,Ltd.

King Of Valve Co.,Ltd. Series variation Series Series Series variation SCP* SCP* U Variation Double acting lubrication type Double acting oil-free type, with switch Double acting Stroke adjustable type (Extended) Double acting

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance

Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance Series variation Quick exhaust, and circuit switchover valves, etc. are available Model Product appearance Model no. Port size (Rc) Page 4 dia. dia. M /8 /4 /8 / /4 /4 / QEV-A Quick exhaust valve QEV-8A

More information

Lubricator Series Functional explanation / Dimensions

Lubricator Series Functional explanation / Dimensions 00E/00E Series Lubricator / utofill type Only installing oil tank enables lubrication to multiple lubricator. : Rc/ to Rc JIS symbol ir uto. drain Specifications escriptions 00E///V 00E/8V ompact lean

More information

HMV/HSV. Manual selector valve. 4-port valve CONTENTS

HMV/HSV. Manual selector valve. 4-port valve CONTENTS 4-port valve Overview The / series manual selector valves are 4-port valves with a sliding valve method for the main valve. Suitable for operating cylinders of φ0 to φ0. Features Simple ease of operation

More information

Product series extended even more! Non-rotating Type. Offers 3 types of non-rotating operation types. push type cylinders. pull type cylinders

Product series extended even more! Non-rotating Type. Offers 3 types of non-rotating operation types. push type cylinders. pull type cylinders The Pen Cylinder s compactness and easy handling make production lines in a broad range of industries. new release with even lighter weight and more PEN CYLINDERS Product series extended even more! The

More information

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold K/K, pilot operated valve neumatic valve / master valve MNE0 MNE0 M MN W WG MNS0 MNS0 T L-/ S/0 S/ K/ F CONTENTS Safety precautions 776 Discrete valve ody ing (K/K to ) 868 Sub-plate ing (K to ) 87 Manifold

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard Hand Valve Series Specifications 0 0 Fluid Proof pressure Max. operating 00/00/00 pressure 0 mbient temperature and operating fluid temperature Operating angle Lubrication ir.5 MPa.0 MPa MPa 5 to C (o

More information

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve: Port Valve For Compressed ir and ir-hydro Circuit Control Series VN Style VN -6 VN -8 8 VN - 3 8 VN - 5 VN -5 VN3-0 3 0 Note) This product cannot be used for water application. JIS Symbol

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Transmitters: Relay Valve

Transmitters: Relay Valve Relay Valve VR5/5 Series Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system. Specifications

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard Hand Valve Series VH Specifications Fluid Proof pressure Max. operating VH00/00/00 pressure VH00 Ambient temperature and operating fluid temperature Air.5 MPa.0 MPa MPa -5 to 0 C (No freezing) VH0 VH00

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Center Center Exhaust Pressurized PS-32AS PS-32BS PS-32AD PS-32BD PS-520S PS-520D PS-53CD PS-53ED PS-53PD. Series PS. Function

Center Center Exhaust Pressurized PS-32AS PS-32BS PS-32AD PS-32BD PS-520S PS-520D PS-53CD PS-53ED PS-53PD. Series PS. Function DIRECTIONL CONTROL VLVES Directional Control Valves PS-SERIES 3/2, 5/2 and 5/3-way Single and double acting control Long lifespan Low energy consumption Standard manual override Wide range of operating

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet

More information

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. CCESSORIES GENERL CTLOG IR TRETMENT, UXILIRY, VCUUM, ND FLUORORESIN PRODUCTS ELECTRO-PNEUMTIC TRNSDUCING REGULTORS CONTENTS ETR Series Features, Operation Principle 237 pplication Examples 238 Handling

More information

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application. CC-1104A GHV Series 3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application. Main features Space-saving integrated structure Two solenoid valves

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting S Series Push-lock Type Reduces labor time! Easy to use Easy to lock Unlock Push-lock type Lock Improved tube insertion/removal Max. Insertion force: 30% (8 N) reduction

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series AN05 to 40 RoHS

Series AN05 to 40 RoHS Silencer Compact Resin Type/Male Thread N0 to 40 RoHS How to Order N 0 Body size Specifications 0 0 30 40 Thread type M thread Nil R N NPT Thread connection port size pplicable model M 0 0 03 04 M x 0.8

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

R1000/R3000/R4000/R8000 Series

R1000/R3000/R4000/R8000 Series Regulator R/R/R/R Series Compact pressure gauge integrated type : Rc/ to Rc JIS symbol CAD DATA AVAILABLE. Specifications Descriptions R R R R Appearance Working fluid Max. working pressure Withstanding

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center) Hand Valve Series VH Specifications VH VH Fluid Proof pressure Max. operating VH// pressure VH Ambient temperature and operating fluid temperature Operating angle Lubrication Air.5 MPa. MPa MPa 5 to C

More information

Energy efficiency and Flow

Energy efficiency and Flow Energy efficiency and Flow or more Estimating figure with ø6 push-in fittings Primary pressure: 0.5MPa Secondary pressure: Release to atmospheric pressure Oil-prohibition type Suitable for oil-restricted

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

MANIFOLD REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MANIFOLD REGULATORS

MANIFOLD REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MANIFOLD REGULATORS CCESSORIES GENERL CTLOG IR TRETMENT, UXILIRY, VCUUM, ND FLUORORES PRODUCTS MNIFOLD REGULTORS MNIFOLD REGULTORS CONTENTS Features, Flow Rate Characteristics 115 Specifications, Port Size 116 Inner Construction,

More information

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure, Pneumatic components (Electro pneumatic Regulator) Safety Precautions Read this before starting use. Please refer to Intro 43 for general details on the pneumatic components, and to " Precautions" in this

More information

PROCESS & AUTOMATED VALVES

PROCESS & AUTOMATED VALVES Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline

More information

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication Hand Valve VH Series VH0 Specifications VH0 Fluid Proof pressure Max. operating VH00/00/00 pressure VH0 Ambient temperature and operating fluid temperature Operating angle Lubrication Air.5 MPa.0 MPa MPa

More information

Mechanical Style Pressure Switch. Specifications

Mechanical Style Pressure Switch. Specifications or details about certified products conforming to international standards, visit us at www.smcworld.com. Mechanical Style Pressure Switch Series IS1000 Long service life: 5 million cycles IS1000-01 IS1000-01-X202

More information

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA Series V irect Operated Port Solenoid Valve for Oil Series V VX VN V VW V V P.-9 Multipurpose Valve for Oil irect Operated Port Solenoid Valve for Oil Series V Kerosene, uel oil class (fuel oil ), Silicone

More information