NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Size: px
Start display at page:

Download "NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute"

Transcription

1 RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations UL077 recognized Supplementary Protectors RAS RA UL Recognized File o. E68029 E74843 CSA Certified File o. LR47985 RAR Rocker RAR Illuminated Rocker (neon lamp) Specifications Protection Method Internal Circuit umber of Poles Rated Voltage Rated Tripping Currents Rated Interrupting Capacity Auxiliary Contact Alarm Contact Electromagnetic tripping Series current trip RAS and RA:, 2, 3 RAR: 250V AC, 50/60Hz, 65V DC. RAR is not CSA certified. 2. ot suitable for branch circuit protection. 0.30A, 0.50A, 0.75A A, 2A, 3A, 5A, 7.5A, 0A, 5A, 20A, 25A, 30A 250V AC, 50/60Hz,,000A 65V DC,,000A SPDT microswitch 250V AC, 5A (resistive load) 50V DC, A (resistive load) Reference Temperature 25 C Operating Temperature 40 to +85 C (avoid freezing) Insulation Resistance MΩ minute (measured with 500V megger) Dielectric Strength Between main circuit terminals: 2,000V AC, minute Between main circuit and auxiliary contact: 2,000V AC, minute Vibration Resistance (approximately 0G) (0 to Hz) Shock Resistance,000 (approximately G) Life Expectancy Minimum 0,000 cycles (at 6 operations per minute) Termination Illumination Voltage (RAR illuminated units) Main terminal: Quick-connect receptacle 0.250" (accepts M3.5 screw terminal adapter) Auxiliary contact, alarm contact: Quick-connect receptacle 0.080" eon: 20, 240V AC, 50/60Hz LED: 2, 24V DC -4 USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC

2 RA Series Part umbering Guide RA series part numbers are composed of up to 8 part number codes. When ordering an RA series part, select one code from each category. Example: RAR -F - 30A -AA -3 RAR F 30A AA 3 ➀ Model ➁ Poles ➂ Internal Circuit ➃ Auxiliary and Alarm Contacts 5 Inertia Delay ➅ Rated Current ➆ Time Delay 8 Pilot Curve Light * Part umber Codes: RA Series Description Part umber Code Remarks ➀ Model ➁ o. of Poles Toggle (round cutout) Toggle (rectangular cutout) Rocker RAS RA RAR -pole RAR available in -pole only. 2-pole 2 All multi-pole circuit breakers are simultaneous throw/simultaneous break. 3-pole 3 All levers are mechanically interlocked. ➂ Internal Circuit Series current trip ➃ Auxiliary and Alarm Contacts 5 Inertia Delay ➅ Rated Current ➆ Time Delay Curve 8 Pilot Light* Without 00 With auxiliary contact With alarm contact 2 Without inertia delay With inertia delay Rated current (current trip) DC curves AC curves With neon light 20V AC (50/60Hz) With neon light 240V AC (50/60Hz) 2 Blank F 0.30A, 0.50A, 0.75A, A, 2A, 3A, 5A, 7.5A, 0A, 5A, 20A, 25A, 30A AD, MD AA, BA,MA. For RA series accessories, see page For RA series time delay curves, see page For RA series dimensions, see page ot suitable for branch circuit protection. 5. UL recognized, applicable standard: UL077, Supplementary Protectors. 6. RAR is not CSA certified. All current ratings must be listed in amps (A). Example conversions: 50mA = 0.05A, 300mA = 0.30A. For time delay curves, see page -9. * Applicable to illuminated RAR only. USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC -5

3 RA Series Information About Circuit Breakers Time Delay Curve Descriptions Time Delay Curve AD, AA BA MD, MA With Inertia Delay RA Application Common curves used in molded-case circuit breakers. Response to overcurrent is quite fast. Suited for protection of semiconductor circuits with very little overload tolerance. If overcurrents are expected to flow, fuses may be required according to the circuit characteristics. Suited for motor loads that draw high inrush currents lasting a considerable length of time. Designed not to trip on 20 times the rated current (peak value) for a duration of 8ms. Suited for transformer and lamp loads that draw steep inrush currents. Inertia Delay Descriptions Circuit breakers equipped with inertia delay do not respond to high inrush currents such as those produced by transformer, lamp, or motor loads, but perform the specified interruption on the rated overcurrents. Specify inertia delay by inserting an F in the part number as shown in Part umber Guide on previous page. 6,000 4,000 2,000 0,000 8,000 6,000 4,000 Pulse Width Pulse Peak Current (duration) 2, Pulse Width (ms). = Pulse Peak Current x % Protector Rated Current 2. Based on sinusoidal or parabolic pulse profile. otes Multi-Pole Multi-pole types such as 2- or 3-pole should be assembled by IDEC. Because of their characteristics, -pole breakers cannot be combined to provide multi-pole units. Auxiliary and Alarm Contacts Multi-pole units can incorporate auxiliary and alarm contacts. Auxiliary and alarm contacts will not work with IDEC s DI rail adapters USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC

4 RA Series Accessories Part umbers: RA Series Accessories Description Appearance Part o. Remarks Color Caps (RAS only) Red Blue Yellow Ø 0.62" (5.8mm) R5R R5S R5Y Colored Cap Panel White R5H Colored caps fit onto RAS circuit breakers for color coding circuits and improving the appearance of the panel. Terminal Socket MS-C For connection with auxiliary or alarm contact terminals. Screw Terminal Adapter ( pair) RT For use on main terminals only. Includes M3.5 clamp screw. For dimensions see page -25. Part umbers: RA Mounting Accessories Description Appearance For Model Panel Mount Flush Plate 0.936" (24mm).89" (48.5mm) 2.65" (68mm) 2.46" (63mm) RA RAR o. of Poles -pole Part o. R3 RA 2-pole R32 RA 3-pole R33 Remarks Use of a flush plate makes snap-in mount possible for RA, and RAR circuit breakers (tightening screws not necessary). Multiple units can mount in a single panel cut-out. DI Rail Plug-in Base Mounting Clip DI Rail 0.757" (9.4mm) -Pole.50" (38.5mm) 2-Pole 2.26" (58mm) 3-Pole Hold-Down Spring RAS RA -pole 2-pole 3-pole R2 R22 R23 RAR -pole R2.Furnished with a holddown spring. 2.Applicable only for series trip units up to 20 amps. 3.ot applicable for RAR lighted series. 4.ot for use with circuit breakers incorporating auxiliary or alarm contacts. Surface Mount Plug-in Base RAS RA -pole 2-pole 3-pole US US2 US3 RAR -pole US For dimensions of RA series accessories and panel cut-out layouts, see drawings starting on page USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC -7

5 RA Series Internal Circuits and Terminal Arrangements: RAS and RA Series LIE with Auxiliary Contacts LIE with AlarmContacts LIE C O O C C C Internal Circuits and Terminal Arrangements: RAR Series with Auxiliary Contacts with Alarm Contacts (+) Lead Wire A Lead Wire B C Lead Wire A Lead Wire B C LIE ( ) LIE O C LIE C O Pilot Lights (RAR only) Lead Wire Pilot Light A B eon (20V AC) White White eon (240V AC) Black Black Dashed lines represent RAR illuminated rocker units. Lead wires for neon pilot light/led are colorcoded as shown above USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC

6 RA Series Time Delay Curves (numerical equivalent) Overcurrent Time Delay Characteristics in Seconds (at 25 C) Curve % 25% 50% 200% 400% 600% 800% 0% AC (50/60Hz) DC AD o trip MD o trip AA o trip BA o trip MA o trip All values above are in seconds. 2. Data in this table is equivalent to information presented in following time delay curves. DC Time Delay Curves,000,000 AD Delay Curve at 77 F (25 C) MD Delay Curve at 77 F (25 C) Time in Seconds Time in Seconds , , USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC -9

7 RA Series AC (50/60Hz) Time Delay Curves,000,000 AA Delay Curve at 77 F (25 C) BA Delay Curve at 77 F (25 C) Time in Seconds 0 0. Time in Seconds , ,000,000 MA Delay Curve at 77 F (25 C) 0 Time in Seconds , USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC

8 RA Series Resistance and Impedance Characteristics Coil Data for at 25 C Rated AC Impedance DC Resistance Current (50/60Hz) Curves AA, BA, Curves AD, MD MA 0.30A 9.67Ω 9.82Ω 0.50A 3.24Ω 3.36Ω 0.75A.45Ω.49Ω A 0.90Ω 0.92Ω 2A 0.2Ω 0.2Ω 3A 0.09Ω 0.092Ω 5A 0.036Ω 0.036Ω 7.5A 0.07Ω 0.08Ω 0A 0.02Ω 0.02Ω 5A Ω Ω 20A Ω Ω 25A Ω Ω 30A Ω 0.004Ω Tolerance ±25% (up to 20A), ±50% (25A and over). Rated Current (A) Rated Current (A) Coil Resistance at 25 C 0 Curves AD, MD Coil Resistance (Ω) 0 Curves AA, BA, MA 0. Voltage Drop Due to Resistance or Impedance The internal resistance or impedance of a circuit breaker tends to be larger for a smaller rated current. Therefore, when circuit breakers with a small rated current are used, voltage drop should be taken into consideration. Internal resistance also varies with time delay curves, even at the same rated current. This should also be considered during installation Impedance (Ω) Time Delay Curve and Ambient Temperature Since RA series circuit breakers employ an electromagnetic tripping system, the rated current (trip current) is not affected by the ambient temperature, but the time delay varies with the oil viscosity in the tube. Lower oil viscosity at higher temperatures results in shorter delay; whereas at lower temperatures, the delay will be prolonged. The time delay curves, shown starting on page - 9, are at 25 C. Time delay curves can be corrected. Rated Current (A) Temperature Correction Curves Ambient Temperature ( C) Curves AD, AA, BA (on 25% rated current) 90 USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC -

9 Instructions Instructions: All Series General IDEC s circuit breakers have been developed for the protection of electrical circuits and small-sized electrical equipment and provide excellent protection against overloads and short-circuits. Additionally, IDEC s circuit breakers are designed to suit specific needs. Each series offers unique circuit protection characteristics and a choice of actuator styles. IDEC s Circuit Breaker Features Various models are available with different internal circuits, tripping characteristics, and rated currents - to 3- multi-pole Inertia delay Auxiliary contacts and alarm contacts The electromagnetic tripping system is not affected by ambient temperature Safe trip-free mechanism Vibration- and impact-resistant design When using accessories such as plug-in bases, flush plates, and colored caps, a variety of mounting styles is possible such as DI rail mounting, snap mounting into panel cut-outs, and color-coded arrangement on the panel Mounting Instructions: Installation Angle Designed to be mounted on a vertical surface, the circuit breakers should be mounted on a surface within 0 of the vertical plane. If the circuit breaker is mounted on a horizontal surface or at any angle other than the specified angle, its characteristics will be changed. Multi-Pole Assemble Multi-pole types such as 2- or 3-pole should be assembled by IDEC. Because of their characteristics, -pole breakers cannot be combined to produce multi-pole units. Applications The IDEC RA circuit breaker series features superior overload and short-circuit protection. Many combinations of protection mechanisms and internal circuit connections enable wide applications. Precision measuring instruments: electronic counters, projection instruments, oscilloscopes, industrial instrumentation, and analytic devices Electronic communication devices: facsimile machines, computers, recorders Industrial machinery: printers, elevators, cranes Chemical and food industry machines: vacuum devices, wrappers, centrifuges, agitators Machine tools: mill grinders, drills, presses Business machines: automatic vendors, medical equipment, beauty salon equipment, entertainment games Other: office equipment, air-conditioners, conveyor belts, and many more How the Breaker Operates IDEC s hydraulic magnetic circuit breakers operate like a solenoid coil. The coil unit consists of an oil-filled tube with a metal core at one end and a pole piece and armature at the opposite end with a spring in between. When a current load passes through the coil winding, it creates a magnetic field. As long as the current load is either at or below the nominal rating of the breaker, the metal core will remain stationary. If the current load increases beyond the nominal rating, the strength of the magnetic field causes the core to move toward the pole-end of the tube. The oil viscosity regulates the core s movement through the tube, thereby regulating the time delay. As the percentage of current load increases, the required trip time of the breaker decreases and vice versa. When the current reaches the overload rating, the metal core will meet the pole piece at the opposite end of the tube. At this point, the armature is attracted to the same pole piece, tripping the breaker. In case of sudden short circuit, the magnetic field created will instantly trip the breaker.. Internal Circuits Overview Description Circuit Example Load Series Trip This is the most common circuit breaker, providing excellent overload and short circuit protection. It can also be used as an O/OFF switch. Load A Series Trip with Auxiliary Contact Since the auxiliary contact operation is interlocked with the O/OFF of the main contactor, circuit breaker operation can be monitored by a lamp or buzzer. This circuit breaker can also be used to control auxiliary circuits up to 250V AC/5A (resistive load). Load B Load A Series Trip with Alarm Contact Since the alarm contact is electrically independent of the main contactor, but actuates when the protective element operates. The alarm can be used with a lamp or buzzer to monitor trip operations, and can also be used for controlling alarm circuits. The contact rating is 250V AC/5A (resistive load). Load B USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC

10 Dimensions Dimensions Dimensions: RA Series 0.250" Tab Terminal 0.0" Tab Terminal RAS 2.03" (52mm).65" (42.2mm).20" (30.8mm).20" (30.8mm) 60.56" (40mm) -pole: 2-pole:.49" (38.2mm) 3-pole: 2.23" (57.3mm) 0.683" (7.5mm).56" (40mm).93" (49.5mm) 2." (54mm) 0.250" Tab Terminal 0.0" Tab Terminal RA 2.03" (52mm).65"(42.2mm).23"(3.5mm).20" (30.8mm) 60.56" (40mm) -pole: 2-pole:.49" (38.2mm) 3-pole: 2.23" (57.3mm) 0.644" (6.5mm).60" (4mm).97" (50.5mm) 2." (54mm) 0.250" Tab Terminal 0.0" Tab Terminal RAR 2.03" (52mm).65" (42.2mm).23" (3.5mm) O OFF LED 0.78" (20mm).56" (40mm) 2.8" (56mm) 0.47" (0.7mm) 2.55" (65.5mm) 2.69" (69mm) Dimensions: RBM Series M5 Stud 0.0" Tab Terminal RBM 2.46" (63mm) 2.04" (52.3mm).37" (35mm).35" (34.7mm) (49.2mm) -pole: 2-pole:.49" (38.2mm) 3-pole: 2.23" (57.3mm) 0.8" (20.5mm).85" (47.5mm) 0.624" (6mm) 2.48" (63.5mm) USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC -25

11 Dimensions Panel Cut-Outs Installation Angle: Circuit breakers are designed to operate on a vertical surface. The mounting angle should not exceed a vertical plane by more than 0. RA Series RAS Ø0.58" (4mm) Mounting Holes RAR, RA Ø0.56" (4mm) Mounting Holes 0.630" (6mm).05" (26.7mm).66" (42.2mm) 0.20" (5.mm).26" (32mm).66" (42.2mm) -Pole 2-Pole 3-Pole.49" (38.2mm) 2.23" (57.3mm) R3, R32, R33 Panel Mount Flush Plate 2.09" (53.5mm).5" (38.7mm) 0.764" (9.6mm) 2.25"(57.8mm) Maximum Mounting Distance Model A B Schematics in Inches (mm) RAS 3.02" (77.5mm) 3.57" (9.5mm) Mounting to Panel Surface Mounting to DI Rail RA 3.02" (77.5mm) 3.57" (9.5mm) RAR 3.38" (86.7mm) 3.93" (.7mm) USA: (800) 262-IDEC or (408) , Canada (888) 37-IDEC

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series RAS RA Key features of the RA series include: Available in 4 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over

More information

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Section. Circuit Breakers   Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series... Section Selection Guide...-2 RA Series...-3 RBM Series...-3 RC Series...-20 General Instructions...-29 Internal Circuit Overview...-29 for more information on this product family visit www.idec.com/circuitbreaker

More information

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

Circuit Protector Selection Guide

Circuit Protector Selection Guide ircuit Protectors ircuit Protector Selection Guide Model NV NHS NHY NHL (w/indicator) NHV Shape ping Method No. of Poles Internal ircuit Rating Retractable Actuator Lever Rocker Rocker Lever Hydraulic-magnetic

More information

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73 Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 perating Characteristics 73 Delay Curves 74 Specifications 76 Decision Tables 78 SIGLE

More information

Circuit Protectors CP31F, 32F, 33F

Circuit Protectors CP31F, 32F, 33F CP3F, 32F, 33F CP-F slim type circuit protectors 20V AC/6V DC (-pole) 0.A to 30A 20V AC/2V DC (2-pole) 0.A to 30A 20V AC (3-pole) 0.A to 30A Description FUJI's compact and high-performance CP-F series

More information

Miniature Switches & Pilot Devices

Miniature Switches & Pilot Devices A8 Series Miniature Switches and Pilot Devices: 8mm Key features of the 21/64" (8mm) A8 series Switches and Pilot Devices include: 21/64" (8mm) round mounting hole Compact Design Saves Space Bright and

More information

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS Circuit protectors Circuit protectors Air circuit breakers Air circuit breakers AFaC and BaC types HRC fuses BLC, CR and CS types Super Rapid Fuses

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series Industrial Automation Catalog Section - U906 Relays Selection Guides General Purpose Relays RU Series RR Series For up-to-date information, or to request a full copy of this catalog, contact us at www.idec.com

More information

G-Series. Circuit Breaker.

G-Series. Circuit Breaker. -Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs. Switching Expandable and space-saving switching power supplies. High efficiency reduces operation costs. 93% efficiency Plug-in output modules for additional output voltages Plug-in branch terminal module

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

ø8 A8 Series Miniature Control Units

ø8 A8 Series Miniature Control Units A8 ø8 A8 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada Key features: SPDT through PDT, 0 contacts Midget power type relays vailable in pin and blade terminal styles. Options include an indicator, check button for test operations and side flange. Series Power

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

GT5P Series ON Delay Timers

GT5P Series ON Delay Timers T5P Series T5P Series ON Delay Key features of the T5P series include:, 5A contacts 8-pin, octal base 9 time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing

More information

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp 48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp E13224 The 48 series is a contactor with a 4 normally open, double make contacts rated up to 3HP. It uses a solenoid type moving core design

More information

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight VDE 2c, 3c AMP POWER RELAY RELAYS 2. 1.72 FEATURES Interchangeable with existing models Long life and high reliability High contact capacity up to A 20 Available with plug-in/solder and quick-connect terminals

More information

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59. Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection,

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

209/219/229/249/279 Series Magnetic Circuit Protectors

209/219/229/249/279 Series Magnetic Circuit Protectors 29/29/229/249/279 29/29/229/249/279 Series Magnetic Circuit Protectors Introduction 65 249 Power Selector System 67 Multi-Pole 69 Configurations 7 Operating Characteristics 73 Delay Curves 74 Specifications

More information

INDIVIDUAL CATALOG08 from D&C CATALOG 20th Edition

INDIVIDUAL CATALOG08 from D&C CATALOG 20th Edition CP-F type Circuit protectors CP-P type Circuit protectors CP-B type Circuit protectors CIRCUIT PROTECTORS CP-V type Circuit protectors LOW VOLTAGE CURRENT - LIMITING FUSES AFaC and BaC types HRC fuses

More information

209 Series. Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors 29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279

More information

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches HSC HSC Full Size Solenoid Locking Switches Key features: Rugged aluminum die-cast housing 00N locking retention force Flexible Installation: The actuator can be accessed from two directions Select from

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers Standard Series Key features: Wide power range: 7.W-4W Universal input : 7.W-W: 8-264V /1-37V DC W: 8-2V /17-264V 24-37V DC (selectable) W, W, 24W: 8-264V /11-3V DC 4W: 3 phase: 32- V 3 phase: 3- V Overcurrent/overvoltage

More information

ø10 A1 Series Miniature Control Units

ø10 A1 Series Miniature Control Units A1 ø10 A1 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

SPECIFICATION OF CIRCUIT BREAKER

SPECIFICATION OF CIRCUIT BREAKER SPECIFICATION OF CIRCUIT BREAKER Principle of operation 1, Principle of operation of hydraulic magnetic circuit breaker (see drawing 1) The circuit breaker adopts a hydraulic magnetic tripper to protect

More information

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches Locking Safety Switches HSE HSE Full Size Locking Switches Key features: Plastic Housing: Lightweight 00N locking retention force Available with a red or green indicator Choose from circuit configurations

More information

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables JAE Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables 205 207 211 213 216 217 JAE/JRE/JLE Series Hydraulic Magnetic Circuit Protectors

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Catalog Issued 3-03 (PDF Rev )

Catalog Issued 3-03 (PDF Rev ) W6/W9 series Magnetic Hydraulic P& Circuit reakers Features Designed for the international market. UL Recognized (UL77 and UL5), CS ccepted and VDE approved. Ratings to 5 amps. Heavy duty #-32 stud connections.

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Standard Series Standard Series Switching Part Numbers Part Number Item Watts Rated Voltage Rated Current -A V DC 1.A -A 7. V DC.6A -A24 24V DC.3A -B V DC 2.A Key features of the standard series include:

More information

ø12 A2 Series Miniature Control Units

ø12 A2 Series Miniature Control Units ø2 A2 Series Miniature Control Short 22-mm-long body miniature control unit series with bright LED illumination face and snap-action switching. Degree of protection: IP40 and IP5 (IEC 0529) All series

More information

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz Miniature Magnetic Latching Key features of the RY2L series include: Standard ice cube, 14-pin solder lug termination Operates by pulse input and maintains condition even during power failure Coils rated

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Non-Illuminated ushbuttons (Sub-Assembled) Contact Block + Operator + Button = Completed Unit art Numbers: Operators Style art Number Momentary Maintained LW1B-M0 LW1B-A0 LW2B-M0 LW2B-A0 Mushroom

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 609) of compact design for snap-in panel mounting. Available

More information

PS6R 480W Switching Power Supply

PS6R 480W Switching Power Supply ew Series PS6R 4W Switching Power Supply Reduced size and high efficiency cuts operating costs. Energy-saving 93% Efficiency Space-saving 85mm wide Efficiency (%) 96 94 92 88 86 84 82 Competitor A Competitor

More information

Relays & Sockets. RQ Series PCB Relays

Relays & Sockets. RQ Series PCB Relays RQ RQ Series PCB Relays IDEC RQ relays are low-profile, PCB relays in a compact package. Size equals value. RQ relays are small, yet maintain high contact ratings and long operational life. For larger

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

DD Frame - Series Circuit Breakers

DD Frame - Series Circuit Breakers The DD Frame is a compact yet very powerful circuit breaker. Using the hydraulic-magnetic technology which ensures that the breaker performance is unaffected by ambient temperature, the CI DD Frame series

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

SAR & SAS Circuit Protectors

SAR & SAS Circuit Protectors SAR & SAS Circuit Protectors 280 QAS, QAL, QFS, QFL Quick-Action Fuses 282 HVS & SARPV Compact Switches for 28 Solar Power Applications SAR & SAS Circuit Protectors Applications: Typical applications include

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Plastic Bezel Metal Bezel Ø 40mm Pushlock Turn Reset 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* 2NC HW1X-BV402-R* HW4X-BV402-R*

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

WHITE PAPER. DIRTY DOZEN: The 12 Most Common Mistakes of Specifying Circuit Protection for Equipment. E-T-A Circuit Breakers

WHITE PAPER. DIRTY DOZEN: The 12 Most Common Mistakes of Specifying Circuit Protection for Equipment. E-T-A Circuit Breakers DIRTY DOZEN: The 12 Most Common Mistakes of Specifying Circuit Protection for Equipment E-T-A Circuit Breakers USA 1551 Bishop Court Mt. Prospect, IL 60056 (847) 827-7600 fax: (847) 827-7655 usinfo@e-t-a.com

More information

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,

More information

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter. Standard AC SB5W Standard AC Intro duction Induction Reversible Right -Angle Gearheads SB5W AC Speed Control Inverter SB5W US ES2 FE1/FE2 Watertight, Dust-Resistant Torque Accessories Installation A-143

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting.

More information

NC1V. Circuit Breakers

NC1V. Circuit Breakers 1V ircuit Breakers IDE's original Spring-up Terminals and over Provide IP20 Fingersafe Protection. 17.5 mm 3 mm 52.5 mm mm (1-pole) (2-pole) Auxiliary/alarm contact terminals are supplied with fingersafe

More information

AR circuit breaker - Hydraulic magnetic,

AR circuit breaker - Hydraulic magnetic, AR circuit breaker - Hydraulic magnetic, Datasheet railway, small Features Description Small hydraulic magnetic circuit breaker for railway applications to protect electronic equipment and components against

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Miniature Solenoid Locking Switches Overview X Series E-Stops HSE features: World s smallest 4 contact solenoid interlock switch. (3 x x 46 mm) Four contacts Gold-plated contacts

More information

CX-Series. Circuit Breaker

CX-Series. Circuit Breaker CX-Series Circuit Breaker The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications

More information

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter Direct On Line (DOL) Motor Starter Direct Online Motor Starter Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting.

More information

Products :: Circuit Protection :: Thermal Circuit Breakers

Products :: Circuit Protection :: Thermal Circuit Breakers Products :: Circuit Protection :: Thermal Circuit Breakers Thermal Circuit Breaker CLB-Series CLB-Series PDF elibrary The CLB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

TA Ta VA CTRL-XFRMR

TA Ta VA CTRL-XFRMR 3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,

More information

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality Full Size Interlock Switch with Locking Solenoid HSC Key features include: Rugged Aluminum Die-cast Housing With the actuator mounted on a movable door, and the switch on a machine, the door can be mechanically

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information

1 Form A 5A small size power relay for interface

1 Form A 5A small size power relay for interface 1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch

More information

Table of Contents. HCC Contactor Nomenclature

Table of Contents. HCC Contactor Nomenclature Table of Contents HC HCC SERIES: Definite Purpose Contactors... Page 1 Auxiliary Switches & Termination Drawings HCC SERIES: 1 & Pole Definite Purpose Contactors... Page 0 HCC SERIES: & Pole Definite Purpose

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 609) of compact design for snap-in panel mounting. Available either with protection on one/both/all

More information

FR circuit breaker - hydraulic magnetic,

FR circuit breaker - hydraulic magnetic, FR circuit breaker - hydraulic magnetic, Datasheet railway, very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

JOSLYN CLARK VACUUM CONTACTORS

JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS SECTION JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS 339 TM CONTENTS Joslyn Clark - New 300Amp, 1140 Volt Heavy Duty Mining Vacuum

More information

ER circuit breaker - Hydraulic magnetic,

ER circuit breaker - Hydraulic magnetic, ER circuit breaker - Hydraulic magnetic, Datasheet railway, high current and voltage Features Ideal for high current and high voltage applications Precise, temperature independent operation Panel mount

More information

G-Series DIN-RAIL CIRCUIT BREAKER

G-Series DIN-RAIL CIRCUIT BREAKER G-Series DIN-RAIL CIRCUIT BREAKER The G-Series hydraulic-magnetic circuit breaker insures maximum protection by integrating wiping contacts for longevity; a common trip linkage between poles; a unique

More information

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Technical data. Miniature Circuit Breakers. System pro M. System pro M Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws

More information

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Series HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Key features include: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

Industrial Relay KML(1C, 2C)

Industrial Relay KML(1C, 2C) Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations

More information