1 Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited for overload protection of motors, pumps, transformers and cables. The 320 circuit breaker is also available as a switch-only version in accordance with the IEC/EN 6058 (see data sheet switch 320-F-..Q). Product characteristics: l rocker or push button actuation l single pole and double pole versions l reliable switching behaviour (positively trip-free) l convenient snap-in mounting l international approvals Options and add-on modules: l illumination l water splash protection l auxiliary contacts l under voltage trip l remote trip l magnetic trip l push-in terminals l appliance inlet module Typical applications Medical and laboratory equipment, apparatus and machine construction, professional tools, household and garden appliances, offices machines, audio equipment, machine tools Current ratings and internal resistance values Current rating (A) Internal resistance per pole (Ω) Current rating (A) Current consumption of illumination Internal resistance per pole (Ω) < < < < < < < Operating voltage Current consumption Y R G DC 2 V 5.2 ma 2 ma.4 ma DC 24 V 4.5 ma 2.2 ma.6 ma DC V 4.5 ma 2 ma.6 ma AC 5 V 2.8 ma. ma ma AC 230 V 2.2 ma 0.9 ma 0.9 ma Technical data For details please see Technical information Rated voltage Current rating range Typical life -pole AC 240 V, DC 50 V A (up to 30A upon request for single pole units) AC 240 V: A 30,000 operations at x I N, inductive DC 50 V: A 30,000 operations at x I N, inductive A 30,000 operations at x I N, resistive DC 28 V: A 30,000 operations at x I N, inductive Typical life 2-pole AC 240 V: DC 50 V: A 50,000 operations at x I N, inductive A 30,000 operations at x I N, inductive A 50,000 operations at x I N, inductive A 50,000 operations at x I N, inductive Ambient temperature C Insulation coordination (IEC 60664) Dielectric strength Operating area pole to pole (2-pole) 2.5 kv /2 reinforced insulation at operating area test voltage AC 3,000 V test voltage AC,500 V Insulation resistance > 00 MΩ (DC 500 V) Interrupting capacity I cn A 0 x I N A -pole 50 A 2-pole 0 A Interrupting capacity (UL 077) I N U N I nc -pole, 2- pole A AC 0 V 5000 A, C, -pole, 2- pole A DC 50 V 000 A, C, Degree of protection (IEC 60529) Vibration Shock Corrosion Humidity Mass operating area IP40 terminal area IP00 with water splash cover IP54 or IP66 8 g ( Hz), ± 0.6 mm (0-57 Hz) test to IEC , test Fc 0 frequency cycles/axis 30 g ( ms) test to IEC , test Ea 96 hours at 5 % salt mist, test to IEC , test Ka 240 hrs in 95 % RH test to IEC , test Cab approx. g (2-pole) approx. 27 g (-pole) approx. 42 g (2-pole with PT terminals) 9

2 Order numbering code Type No. 320 thermal rocker-actuated circuit breaker Mounting method F flange mounting snap-in frame Size of frame 3 standard, to fit mounting cut-out 50.5 x 2.5 mm 5 standard, to fit mounting cut-out 44.5 x 22 mm 7 special style, to fit mounting cut-out 44.5 x 22 mm Number of poles -pole, thermally protected 2 2-pole, thermally protected 5 2-pole, -pole thermally protected Mounting frame design (F3 & F5) collar height mm 3 collar height 9 mm 4 collar height 2 mm with water splash protection (IP54) Mounting frame design (F7) R T black black with snap-on water splash cover Terminal configuration PT push-in terminals P7 blade terminals H7 as P7, terminals and 2 with flat head screws M3.5 - standard for units with undervoltage release module N7 as P7, with additional shunt terminals 2(i) and 22(i) G7 as N7, terminals and 2 with flat head screws M3.5 Characteristic curve T thermal trip Actuator style W rocker for frame size F3 & F5 A rocker for frame size F7 Colour and illumination 0. rocker black opaque 02. rocker white opaque 04. rocker red opaque 4. R rocker red translucent with LED illumination 5. Y rocker orange translucent with LED illumination 9. G rocker green translucent with LED illumination Marking for rocker style W A D F Q X 320 -F 7 2 R - P7 T -A 4 QR 4 0 I I 0 ON OFF A D F X Marking for rocker style A Q»I«and»O«moulded in Illumination voltage range (= operating voltage) DC 2 V 2 DC 24 V 3 AC 5 V 4 AC 230 V 5 DC V Current ratings A Q: 0 and moulded in 320 -F 7 2 R - P7 T -A 4 QR 4-0 A ordering example Order numbering code Type No. 320 thermal circuit breaker with push button actuation Mounting F flange mounting snap-in frame Size 2 special frame for fitting splash cover 3 mounting cut-out 50.5 x 2.5 mm (panel thickness mm) Number of poles -pole, thermally protected 2 2-pole, thermally protected 5 2-pole, -pole thermally protected Style F frame with 2 push buttons G frame with one push button (reset only) Terminal configuration PT push-in terminals P7 blade terminals H7 as P7, terminals and 2 with flat head screws M3.5 - standard for units with undervoltage release module N7 as P7, with additional shunt terminals 2(i) and 22(i) G7 as N7, terminals and 2 with flat head screws M3.5 Characteristic curve T thermal trip Actuators / colour / illumination D0X push button* black opaque D02X push button* white opaque D04X push button* red opaque D9XG push button* green translucent with LED illumination SGRX 2 push buttons green/red opaque without illumination SGRXG 2 push buttons green/red translucent with LED illumination Illumination voltage range (= operating voltage) DC 2 V 2 DC 24 V 3 AC 5 V 4 AC 230 V 5 DC V Current ratings A 320- F 3 2 F - P7 T- S GRXG 4-0 A ordering example *reset only Packaging unit: 20,, 35, 50 or 60 pcs, depending on the version 2 9

3 Preferred types Time/current characteristics preferred type F7 2-pole protected preferred type F3 -pole protected 320-F72R-P7T- A4QR4-320-F3-P7T- W02D- preferred ratings (A) x x x x x x x x x x x x x x x x x x x x x x single or double pole load 0. 2 A C +40 F +23 C F -30 C -22 F preferred type F3 2-pole protected preferred type F5 2-pole protected 320-F52-P7T- W0D- 320-F32-P7T- W0D x x x x x x x x x x x x x x x x x x x x x x x x x Trip time in seconds 00 0 Approvals Approval authority Standard Schematic diagrams Rated voltage VDE IEC/EN AC 240 V DC 50 V DC 50 V DC 28 V UL UL 077 AC 0 V DC 50 V AC 0 V CSA C22.2 No 235 AC 0 V DC 50 V AC 0 V CQC GB 770 AC 240 V DC 50 V Current rating range 0. A 20 A A (2-pole) A (-pole) 0. A 20 A 0, A 20 A 0, A 20 A 30 A (2 poles in parallel) 0, A 20 A 0, A 20 A 30 A (2 poles in parallel) 0. A 20 A 0. A 20 A A Trip time in seconds times rated current +60 C +40 F +23 C F -30 C -22 F 2-pole, thermally protected on both poles line 2 2-pole, thermally protected on one pole only line 2 2(i) 22(i) 2(i) 22(i) times rated current 2(k) load 22(k) -pole, thermally protected 2(k) load The time/current characteristic depends on the ambient temperature. In order to eliminate nuisance tripping, please multiply the current rating by a derating factor (see chapter Technical Information) line ambient temperature [ C] (i) 22(i) Temperature factor (k) load 9 3

4 Dimensions 320-F2.F- retaining clip water splash cover (see accessories) 320-F2.F-PT panel 0.7 cover ø3.2 PT-screw type K40 ø4 mm blade terminal EN x ±0. 2(i) 2(k) 2(i) 2(k) hole for screw ø 4 mm e.g.: EJOT PT screw K ø F F3.-PT OFF position (i) 2(k) 2(i) 2(k) blade terminal EN x F 3.3 collar height 9 mm 320-F 3.4 with water splash protection (IP54) (i) 2(k) 2(i) 2(k) blade terminal EN x blade terminal EN x

5 Dimensions 320-F3.F- -S 320-F3.G-...-D... optional illumination in ON position OFF position optional illumination in ON position OFF position (i) 2(k) 2(i) 2(k) blade terminal EN x blade terminal EN x F F5.-PT 7 6 optional illumination (i) 2(k) blade terminal EN x F , F (i) 2(k) blade terminal EN x blade terminal EN x

6 Dimensions Cut-out dimensions Style F7.R t: metal min. 2 mm (.079 in.) plastic min. 3 mm (.8 in.) ±0.2.89± LINE 2(i) 2(k) ± R2.079 ø blade terminals EN ,3 x 0, Cable cross sections PT terminals F7.R-PT Cut-out for mounting style -F3 with rocker and push button (i) 2(k) Style F7.T LINE 2(i) 2(k) t 320-F2 Edges of working parts: ISO max. R2 max.079 ±0.05 ± min. 2.5 min.098 max. R0.3 max.02 Cut-out for mounting style -F5/-F7 with rocker -4 mm in. max. R0.3 max max. R.5 max.059 ±0.05 ± min. 2 min Edges of working parts: ISO cable cross section with direct push-in wiring,89 rigid 4 mm 2 (stripping length: 0 mm) flexible with wire end ferrule (with or without plastic sleeve) mm cable cross section when opening the push-in terminals rigid mm 2 (stripping length: 0 mm) flexible without wire end ferrule mm blade terminals EN ,3 x 0,

7 Installation drawing Terminal types 320 with blade terminals 320-F52-G7 320-F55-G7 When installing the circuit breaker apply pressure on bezel only. operating area mounting area 320 with push-in terminals 320-F52-N7 320-F55-N7 When installing the circuit breaker apply pressure on bezel only. operating area mounting area 320-F52-H7 320-F55-H7 320-F52-P7 320-F55-P

8 Accessories Insulated cover Y Rear terminal shroud black (IP64) Y blade terminal DIN C-Ms-S (QC 2x.0) Terminal adapter Y R Blanking piece in -F3 frame Y ø matt finish ø ø8.35 Water splash cover, transparent (IP66) for mounting style -F2.. X Mounting of X All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted

9 Accessories Plug-in connector Y Connecting cables can be pre-wired. Two retaining clips ensure a tight fit. 5, ,5 42 2,2 Benefits: Reduced installation time and costs for final assembly Quick replacement of devices Note: Delivery without receptacles. Dimensions of receptacles (width 6.3 mm) are in accordance with DIN part 3, shape A. Examples of suitable receptacles: Stocko RSB 796 F6,3- / Klaucke type 2730 / Vogt type 3832d.67 / TE FASTON Terminals 0 Series / Delphi Packard 58 Series Plug-in connector mounted on circuit breaker: ,

10 Description - Appliance inlet module X320-A/-B The appliance inlet module X320 with circuit breaker type 320-F5/ -F7/-F8 combines up to four functions within a single component: A C4/C20 appliance inlet, a rocker-actuated or push button switch and resettable overcurrent protection and a filter. Screw-type mounting from the front or from the rear. Typical applications Electrical medical apparatus, laboratory equipment, professional audio equipment and office machines. Approvals X320-A X320-B X320-A C4 inlet Authority Standard Voltage ratings Max. current ENEC IEC/EN AC 240 V 0 A UL/CSA UL 498 AC 0 V 5 A CQC CCC AC 0 V 0 A Approvals X320-A filter Design coresponding to UL 283, CSA 22.2 No , IEC/EN X320-B C20 inlet Authority Standard Voltage ratings Max. current ENEC IEC/EN AC 240 V 6 A UL/CSA UL 498 AC 240 V 20 A Selection current rating of the filter Current rating circuit breaker 0,... A A,2...3 A 3 A 3,5...6 A 6 A 7...8A Minimum current rating of the filter 8 A A 0 A 2 A 2 A A 5 A Order numbering code Type No. X320 Appliance inlet module for circuit breaker type 320 Module A appliance inlet C4 (with filter) B appliance inlet C20 (without filter) Mounting 04 screw-type mounting Filter 00 without filter 0 general performance IEC inlet filter 03 general performance IEC inlet filter, medical version 06 high performance IEC inlet filter, medical version Filter current rating 00 without filter 0 A 03 3 A 06 6 A 08 8 A 0 0 A 2 2 A 5 5 A Version 0 not wired; mounting position 320: OFF position to connector wired; mounting position 320: OFF position to connector Assembly status M module supplied with circuit breaker 320 and filter (module A) fitted X320- B M ordering example Circuit breaker type 320 with thermal release protects the filter in case of overloads. For the protection of the filter in the event of higher overcurrents we recommend circuit breaker type 320 with thermal-magnetic release (320...M...). Further technical information upon request. All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted

11 Technical Data (type X320-B, without filter) Rated voltage Current rating (inlet) Ambient temperature Number of poles Protection class: Mounting method: AC 240 V 6 A (IEC) 20 A (UL/CSA) - C C L, N + earth I screw-type mounting (front or rear) Connection: blade terminals DIN mm x 0.8 mm Housing material: thermoplastics, black UL94V-0 Appliance inlet: C20 according to IEC/EN , UL498 Mains switch: Dimensions (type X320-B) Circuit breaker 320-F5/-F7/-F8 (320-F8 with push button actuation: technical data upon request) Technical Data (type X320-A with filter) Rated voltage Current rating (inlet) Current rating (filter) Ambient temperature AC 0 V 0 A (IEC) 5 A (UL/CSA) A, 3 A, 6 A, 8 A, 0 A, 2 A, 5 A - C C Number of poles L, N + earth Protection class: Mounting method: I screw-type mounting (front or rear) Connection: blade terminals DIN mm x 0.8 mm Housing material: thermoplastics, black UL94V-0 Appliance inlet: C4 according to IEC/EN , UL498 Mains switch: Dimensions (type X320-A) Circuit breaker 320-F5/-F7/-F8 (320-F8 with push button actuation: technical data upon request) circuit breaker Ø Ø Ø 3.3 Ø Cut-out dimensions (type X320-B) Cut-out dimensions (type X320-A) 79.5 ±0.3 R (4x) (4x) M3/ Ø ±0.3 Ø 3.6 (2x) Ø.4 (2x) ± ±. 3.5±

12 Electrical schematics X320-A X320-A040 General performance filter N PE P Line Cx 2xL 2xCy N' PE P' 2 Load (K) 22 (K) X320-A0403 und X320-A0406 Medical version N PE P Line Cx R 2xL N' PE P' Load (K) 22 (K) X320-A040 and X320-A General performance filter Typical filter attenuation: Per CISPR 7 A = 50 Ω / 50 Ω sym; B = 50 Ω / 50 Ω asym; C = 0. Ω / 00 Ω sym; D = 00 Ω / 0. Ω sym and 3 A types 6 to 0 A types 2 and 5 A types X320-A High performance filter Typical filter attenuation: Per CISPR 7 A = 50 Ω / 50 Ω sym; B = 50 Ω / 50 Ω asym; C = 0. Ω / 00 Ω sym; D = 00 Ω / 0. Ω sym and 3 A types 6 to 0 A types 2 and 5 A types 2 9

13 Filter selection table Filter Rated current 50 C ( C) A Leakage current 0VAC/50 Hz µa Inductance L mh Capacitance Cx X320-A0400..M (.2) X320-A M 3 (3.5) X320-A M 6 (7.2) X320-A M 8 (0.6) X320-A0400..M 0 (.6) X320-A0402..M 2 (2) X320-A0405..M 5 (5) µf Capacitance Cy nf Resistance R kω X320-A M (.2) X320-A M 3 (3.5) X320-A M 6 (7.2) X320-A M 8 (0.6) X320-A M 0 (.6) X320-A M 2 (2) X320-A M 5 (5) X320-A M (.2) X320-A M 3 (3.5) X320-A M 6 (7.2) X320-A M 8 (0.6) X320-A M 0 (.6) X320-A M 2 (2) X320-A M 5 (5)

14 Description undervoltage release module X320-U Add-on module for circuit breaker type 320. The undervoltage release module trips the 320 circuit breaker/switch combination in the event of a voltage drop or power failure. When the voltage is restored, the 320 must be reset to reconnect the load, thereby avoiding the safety hazards associated with automatic re-start of machinery. Note: Basic unit H7 or -G7 requires screw terminals. Not possible in combination with PT terminals. Dimensions for mains connection Typical applications All machines and devices where automatic re-start after restoration of power could be dangerous, e.g. drilling machines, electric saws, sausage slicers etc. Order numbering code blade terminal 2 DIN A (QC.0) terminal X320-U0 Without separate terminal(s): X320-U00 Type No. X320 module for type 320 Module U undervoltage release module Design 00 standard (without separate connections) 0 blade terminals 2.8x blade terminals 2.8x0.8 Rated voltage 00 AC 230/240 V 50/60 Hz 0 AC 20 V 50/60 Hz Assembly status M module mounted to circuit breaker 320 X320- U M ordering example Schematic diagrams X320-U00 X320-U0 X320-U02 line line line line line 2 A2 2 A A2 2 U< U< U< 2(i) 22(i) 2(i) 22(i) 2(i) 22(i) 2(k) 22(k) load 2(k) load 22(k) 2(k) load 22(k) Technical data Voltage ratings Voltage tolerances + 0 % / - 5 % Typical life Current consumption Release values Release delay Latch-in values AC 00 V; 20 V; 230/240 V (50/60 Hz); DC 24 V 20,000 cycles approx. 2.5 ma 0.2 x U N < U < 0.7 x U N (at a rated voltage of AC 00 V the device can trip at 70 V and must trip at 20 V) < 20 ms 85 % U N Ambient temperature C Vibration Shock Corrosion Humidity Mass 8 g ( Hz), ± 0.6 mm (0-57 Hz) test to IEC , test Fc 0 frequency cycles/axis 30 g ( ms) test to IEC , test Ea hours at 5 % salt mist, test to IEC , test Ka 240 hrs in 95 % RH test to IEC , test Cab approx. 53 g (including base unit) All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted

15 Description auxiliary contact module X320-S Dimensions Add-on module for circuit breaker type 320-F. The auxiliary contact module has a change-over contact as signal contact and is operated with actuation of the CBE. Not possible in combination with PT terminals. Typical applications.5.00 Status monitoring of CBE and/or the connected loads. Order numbering code blade terminals DIN A Ms (QC.0) plated Type No. X320 module for types 320 and 340 Module S auxiliary contact module Contact configuration 0 change-over contact Terminal design blade terminals 2.8 x 0.5 (QC.0), silver-plated Contact rating AC voltage DC voltage Assembly status M module mounted to circuit breaker 320 X320- S 0 A M ordering example * without approval mark rated voltage rated current A 0 V - 0 V A B 5 V - 0 V ma rated voltage rated current 2 V A 24 V A 60 V 0... A 0 V A 220 V A 5 V - 0 V ma Schematic diagram Technical data Rated voltage Current ratings Typical life line (i) 22(i) 3 2(k) load 22(k) AC 0 V, DC 220 V A / ma 50,000 cycles Ambient temperature C Dielectric strength between main and auxiliary circuit test voltage AC 3,000 V module mounted Insulation resistance > 00 MOhm (DC 500 V) Vibration Shock Corrosion Humidity Mass 6 g ( Hz), ± 0.46 mm (0-57 Hz) test to IEC , test Fc 0 frequency cycles/axis 5 g ( ms) test to IEC , test Ea 96 hours at 5 % salt mist, test to IEC , test Ka 240 hrs in 95 % RH test to IEC , test Cab approx. 38 g (including base unit) All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted

16 Description remote trip module X320-M Dimensions A module which adds remote trip capability to all versions of type 320-F. A voltage applied across the coil, by means of an external sensor for example, will cause disconnection of the main switch/ circuit breaker mechanism. Not possible in combination with PT terminals. Typical applications Electrical remote trip of safety systems. Order numbering code Type No. X320 module for type 320 Module M magnetic relay trip module Style 2 magnetic remote trip coil Terminal design P7 blade terminals DIN A Assembly status M module mounted to circuit breaker 320 Rated voltage AC 20, 230 V DC 2, 24 V X320- M 2 P7 M -2 V ordering example blade terminals DIN C-Ms-S (QC 2x.0) Schematic diagram line 2 2(i) 22(i) 2(k) 22(k) load Standard voltage ratings and typical internal resistance values module mounted FA 2(n) remote trip 2 voltage rating internal internal resistance (Ω) voltage rating internal internal resistance (Ω) DC 2 V 0.78 AC 20 V 7.0 DC 24 V 3.3 AC 230 V 32 Technical data Voltage ratings Power consumption Pulse operation Trip time Typical life AC V; DC V approx. 200 Watt 20 ms < t ON < 00 ms / t OFF > 0 sec < 20 ms Ambient temperature C Dielectric strength between main and trip current circuit 50,000 operations at U N test voltage AC 3,000 V Insulation resistance > 00 MOhm (DC 500 V) Vibration Shock Corrosion Humidity Mass 8 g ( Hz), ± 0.6 mm (0-57 Hz) test to IEC , test Fc 0 frequency cycles/axis 30 g ( ms) test to IEC , test Ea 96 hours at 5 % salt mist, test to IEC , test Ka 240 hrs in 95 % RH test to IEC , test Cab approx. 53 g (including base unit) All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection,

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal-Magnetic Circuit Breaker M1-..

Thermal-Magnetic Circuit Breaker M1-.. Thermal-Magnetic Circuit Breaker 30-...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Thermal Circuit Breaker / Switch Series 33 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 609) of compact design for snap-in panel mounting. Available

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting.

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 609) of compact design for snap-in panel mounting. Available either with protection on one/both/all

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Thermal Circuit Breaker / Switch Series 33 Description Combination of single pole circuit breaker and ON/OFF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination.

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics

More information

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data Thermal Circuit Breaker / Switch Series 33 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

High Performance Thermal Circuit Breaker

High Performance Thermal Circuit Breaker High Performance Thermal Circuit Breaker 43-... Description Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

High Performance Thermal-Magnetic Circuit Breakers 410/520/

High Performance Thermal-Magnetic Circuit Breakers 410/520/ High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation CIRCUIT BREAKERS FOR EQUIPMENT TM Series Thermal magnetic release Positively trip-free Reset or manual actuation The TM circuit breaker for equipment (CBE) is a single pole, thermal-magnetically operated

More information

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole TA3 1-pole TA3 2-pole with CZM23 cover TA3 3-pole (pending) Description Thermal circuit breaker 1-, 2- or 3-pole Supplementary

More information

Simulator switch, magnetic operation

Simulator switch, magnetic operation Description Single pole, miniaturised aircraft simulator switch with extremely fast magnetic trip time. Blade, screw and wire wrap terminals. Aircraft style threadneck and push/pull button with white trip

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TeChniCAl DATA

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TeChniCAl DATA Thermal Circuit Breaker, rocker actuated, -, 2- or -pole TA -pole TA 2-pole TA -pole Description Thermal circuit breaker -, 2- or -pole Supplementary protector for general industrial use Positively trip-free

More information

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TECHNICAL DATA

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TECHNICAL DATA Thermal Circuit Breaker, rocker actuated, -, 2- or 3-pole TA3 -pole TA3 2-pole TA3 3-pole Description Thermal circuit breaker -, 2- or 3-pole Supplementary protector for general industrial use Positively

More information

circuit breakers circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, 2- or 3-pole Description Applications

circuit breakers circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, 2- or 3-pole Description Applications Thermal Circuit Breaker, rotary knob actuation, -, - or 3-pole -pole standard version 3-pole type without front bezel/knob standard front bezel/knob Description Thermal circuit breaker -, - or 3-pole Supplementary

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON CIRCUIT BREAKERS FOR EQUIPMENT, POLE, PUSH BUTTON Product description The pole, push button actuated version of the line of thermal CBE s can be used for various purposes. Basically it is a CBE for automatic

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Circuit Breakers. DIN rail-mounted equipment protection

Circuit Breakers. DIN rail-mounted equipment protection Phoenix Contact offers a full family of modular components covering virtually all of your industrial electrical and electronic needs as well as a broad range of value-added services. CLIPLINE DIN rail-mount

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 65W 4-7mA flexc lp ANCED series Product description Built-in constant current LED Driver Adjustable output current between 4 and 7 ma Max. output power 65 W Up to 94 % efficiency Nominal life-time

More information

Equipment Product Overview

Equipment Product Overview Equipment Product Overview A History of Proven Success Integrating E-T-A s 3120 not only allowed us to save space and overall cost, but also allowed us to reduce the number of components and offer the

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

IP20 degree of protection; IP40 degree of protection after installation in a distribution box RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance

More information

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight VDE 2c, 3c AMP POWER RELAY RELAYS 2. 1.72 FEATURES Interchangeable with existing models Long life and high reliability High contact capacity up to A 20 Available with plug-in/solder and quick-connect terminals

More information

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Section. Circuit Breakers   Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series... Section Selection Guide...-2 RA Series...-3 RBM Series...-3 RC Series...-20 General Instructions...-29 Internal Circuit Overview...-29 for more information on this product family visit www.idec.com/circuitbreaker

More information

Functions The Series 19 incorporates the following functions: Indicator Pushbutton Illuminated pushbutton

Functions The Series 19 incorporates the following functions: Indicator Pushbutton Illuminated pushbutton Edition 11/2013 HMI-Components 19 Series Characteristics The compact 8 mm Series 19 is especially suited for: Raised design PCB (with adaptor) The low level switching element is laid out for low current

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

Mini contactors B6, BC6 with 3 pole

Mini contactors B6, BC6 with 3 pole Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

FR circuit breaker - hydraulic magnetic,

FR circuit breaker - hydraulic magnetic, FR circuit breaker - hydraulic magnetic, Datasheet railway, very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet FR circuit breaker - hydraulic magnetic, railway, Datasheet very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements. Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

DD Frame - Series Circuit Breakers

DD Frame - Series Circuit Breakers The DD Frame is a compact yet very powerful circuit breaker. Using the hydraulic-magnetic technology which ensures that the breaker performance is unaffected by ambient temperature, the CI DD Frame series

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

G-Series. Circuit Breaker.

G-Series. Circuit Breaker. -Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current

More information