Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Size: px
Start display at page:

Download "Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies"

Transcription

1 Standard Series Standard Series Switching Part Numbers Part Number Item Watts Rated Voltage Rated Current -A V DC 1.A -A 7. V DC.6A -A24 24V DC.3A -B V DC 2.A Key features of the standard series include: Wide Power Range: 7.W-24W Universal Input: 7.W-W:8-264V AC/1-37V DC 1W:1-V AC/2-24V AC (Selectable) 24-37V DC W-24W:8-264V AC/1-37V AC Fused Input Overcurrent/Overvoltage Protection Power Factor Correction (W, W, 24W models) EN EN Voltage adjustment + 1% Spring-up Screw Terminal, IP2 (finger-safe) DIN rail or Panel Surface Mount Approvals: CE marked U 8 isted U, c-u TÜV approved EMC Directives: EN81-2 EN82-2 EN VD EN9:2 -B 1 V DC 1.2A -B24 24V DC.6A -C V DC 2.A 3 -C24 24V DC 1.3A -D24 24V DC 2.1A -Q24 24V DC 3.1A U 8 isted File # E Cert. No. B E V DC 4.2A -F24 24V DC A -G V DC 1A -8 USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC

2 Standard Series Specifications Specifications Part Numbers Input Output VDC output -A -B* VDC output -A -B -C 24VDC output -A24 -B24 -C24 -D24 -Q24 -E24 -F24 -G24 Output Capacity 7.W 1W 3W W W 1W W 24W Input Voltage (single-phase, 2-wire) Input Current (typical) 1 to 24VAC nominal (8 to 264V AC), /Hz (47 to 63Hz) 11 to 34VDC nominal (1 to 37VDC).17A at 1VAC.3A at 1VAC.68A at 1VAC 1.1A at 1VAC 1.1A 1 to VAC, /Hz 2 to 24VAC, /Hz (jumper selectable) 24 to 37VDC 2.A at 1VAC 1.A at 2VAC 1 to 24VAC, /Hz, 11 to 34VDC 1.8A 4A at 1VAC Internal Fuse Rating 2A 2A 3.1A 3.1A 3.1A 4A 4A 6.3A Inrush Current A maximum (at cold start at 2V AC) 7A maximum (at cold start at 23V AC) A maximum (at cold start at 2V AC) eakage Current (at no load).ma maximum (Hz, measured in conformance with U, CSA, VDE) Typical Efficiency 69% at V 69% at V 73% at V % at V % at V % at 24V 79% at 24V % at 24V 79% at 24V 83% at 24V DC 8% at 24V 83% at 24V DC Overvoltage Protection Outputs turns off at 1% (typical) Voltage and Current Ratings V, 1.A V,.6A 24V,.3A V, 2.A V, 1.2A 24V,.6A 7A maximum (at cold start at 23V AC) 83% at 24V V, 2.A 24V, 1.3A 24V, 2.1A 24V, 3.1A 24V, 4.2A 24V, A 24V, 1A Voltage Adjustments ±1% ( screw on top) Output Holding Time 2ms minimum (at full rated input and output) Rise Time 2ms maximum (at full rated input and output) 1ms max. ine Regulation.4% maximum oad Regulation 1.% maximum Fluctuation due to Ambient Temperature Change.% maximum Ripple Voltage 2% peak to peak maximum (including noise) Overload Protection % typical (Zener-limiting) % typical, auto reset Operation Indicator ED Parallel Operation Dielectric Strength Insulation Resistance Operating Temperature Storage Temperature Operating Humidity -A -B -C -D -Q -E -F -G No Yes No Yes Between input and output terminals: 3,V AC, 1 minute Between input terminals and housing: 2,V AC, 1 minute Between output terminal and housing: V AC, 1 minute Between input and output terminals/input terminals and housing: 1MΩ minimum (V DC megger) 1 to + C (14 to 14 F) (see derating curves) 3 to +8 C (-22 to 18 F) 2 to 9% relative humidity (no condensation) Vibration Resistance 4m/s 2, 1 to Hz, 2 hours on each of 3 axes 1 to Hz,.mm p-p, 2 hrs on each of 3 axes Shock Resistance 3m/s 2 (3G), 3 shocks in each of 6 directions Approvals Conforms to EMC Directives EN81-2 & EN82-2. VD Directive EN29 Certified to EN9. U8 listed. U, c-u, TUV approved. CE marked. EN Weight 1g 17g 3g 39g 8g g g 2g Termination Spring-up, fingersafe terminals with captive M3. screws IP protection IP2 (finger safe) Dimensions H x W x D (mm) x 4 x 7 x 4 x9 x 9 x 9 Dimensions H x W x D (inches) 2.9 x 1.77 x x 1.77 x x 3.4 x 3.74 x 9 x x 3.4 x 3.74 x 8 x 14 x 14 x 9 x 11 x14 x 2x x 3.3 x x.71 x 3.74" 4.72 x 4.3 x x 7.87 x.1 1. For dimensional drawings, see page For usage instructions, see page *.W for VDC model. USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC -9

3 Standard Series Temperature Derating Curves -A/B -C/D E -Q F/G A Mounting B Mounting Operating Temperature ( C) Mounting Style B Mounting Style A Mounting Style A (standard) Vertical Operating Temperature ( C) Mouting style A Mounting Style B (Facing upward) Vertical -1 USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC

4 Standard Series Accessories Part Numbers: Accessories Appearance Description Part Number DIN rail (1mm) BNDN1 DIN rail end clip BN Installation Instructions Time-Saving Spring-up Terminals The innovative terminals on the series use a special, spring-loaded screw. This makes installation as easy as pushing down and turning with a screwdriver. Installation time is cut in half since the screws do not need to be backed out to install wiring. The screws are held captive once installed and are 1% finger-safe. Screw terminals accept bare wire or ring or fork connectors. 1. Insert the wire connector into the slot on the side of the power supply. Overcurrent Protection Characteristics 2. Using a Phillips screwdriver, push down and turn the screw. -A/B -C/D/E 1 1 Output Voltage (%) Output Voltage (%) The wire is now connected, and the screw terminal is finger-safe! Front Panel (terminals) Terminal Name Description V. ADJ +V, V, N NC Voltage adjustment Operation indicator DC output terminals Frame ground Input terminals No connection Adjusts within ±1%; turn clockwise to increase output voltage Green ED is lit when output voltage is on +V: Positive output terminal V: Negative output terminal Ground this terminal to reduce high-frequency currents caused by switching Accept a wide range of voltages and frequencies (no polarity at DC input) Do not insert wires here, as this may damage the power supply Parallel Operation 1 +V (24V) -V (V) TERMINAS 1 EECTRIC OAD Parallel operation only recommended for -Q24, -F24 and -G24. USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC -11

5 Standard Series Dimensions -A (7.W). mm 4. mm 7. mm -B (1W). mm 4. mm 9. mm R2.2 6-ø R2.2 6-ø C (3W) -D (W) 1-ø ø mm 9. mm 9. mm.mm 9.mm 9.mm -Q (W) -E (1W) mm 8. mm 14. mm ø6.. mm 14. mm 9. mm 8 -F (W) G (24W) V mm 11. mm 14. mm 11.mm 2.mm 14.mm USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers Standard Series Key features: Wide power range: 7.W-4W Universal input : 7.W-W: 8-264V /1-37V DC W: 8-2V /17-264V 24-37V DC (selectable) W, W, 24W: 8-264V /11-3V DC 4W: 3 phase: 32- V 3 phase: 3- V Overcurrent/overvoltage

More information

Power Supplies. Automation & Sensing. Selection Guide

Power Supplies. Automation & Sensing. Selection Guide Automation & Sensing Selection Guide... 14 PS5R Slim Line Series... 141 Part Numbers... 142 Specifications... 143 Dimensions and Terminal Markings... 145 PS5R Standard Series... 147 Part Numbers... 147

More information

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs. Switching Expandable and space-saving switching power supplies. High efficiency reduces operation costs. 93% efficiency Plug-in output modules for additional output voltages Plug-in branch terminal module

More information

PS6R 480W Switching Power Supply

PS6R 480W Switching Power Supply ew Series PS6R 4W Switching Power Supply Reduced size and high efficiency cuts operating costs. Energy-saving 93% Efficiency Space-saving 85mm wide Efficiency (%) 96 94 92 88 86 84 82 Competitor A Competitor

More information

PS5R-S. Switching Power Supplies

PS5R-S. Switching Power Supplies TREICHL-ATM Electronic Auf der Bült 1-12 D 41189 Mönchengladbach Tel. 2166 8545 Fax 2166 8547 email: atm@treichl.de internet: www.atm-treichl.de PS5R-S Switching Power Supplies Class Create More Space

More information

GT5P Series ON Delay Timers

GT5P Series ON Delay Timers T5P Series T5P Series ON Delay Key features of the T5P series include:, 5A contacts 8-pin, octal base 9 time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Miniature DIN-track Mounting DC-DC Power Supplies 3- and 7.5-W models. Inputs: 10 to 27 VDC (DC input) Outputs: 5, 12, 15, 24, ±12, and ±15 V. 65 mm depth enables mounting onto panels

More information

Power Supplies. Automation & Sensing.

Power Supplies. Automation & Sensing. Automation & Sensing Selection Guide... 166 PS6R Standard Series... 167 Part umbers... 167 Specifications... 168 Dimensions... 17 PS5R-V Series... 174 Part umbers... 174 Specifications... 175 Dimensions...

More information

Switching Power Supplies

Switching Power Supplies Switching Power Supplies PS5R-V Series PRODUCT DESCRIPTIO DI-rail mount switching power supplies with global approvals for both industrial and hazardous locations KEY FEATURES Compact size preserves panel

More information

Switching Power Supplies

Switching Power Supplies Switching Power Supplies PS5R-V Series PRODUCT DESCRIPTIO DI-rail mount switching power supplies with global approvals for both industrial and hazardous locations KEY FEATURES Compact size preserves panel

More information

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES Switching Power Supply S82F Industrial-Grade Power Supply for General or Peak Load Applications Correct input voltage range is automatically selected: 1 VAC or 2 VAC. Model S82F-P is suitable for peak

More information

INDUSTRIAL POWER SUPPLIES SFL-SERIES

INDUSTRIAL POWER SUPPLIES SFL-SERIES INDUSTRIAL POWER SUPPLIES SFL-SERIES Operating Instructions 1. Application The SFL-series are compact, rugged switching power supplies designed for applications in process automation and other industrial

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Easy-to-use Industrial Power Supply with Versatile Functions (); Power Supply Suitable for Peak Loads such as Motors and Solenoids (-P) Remote control function incorporated. Remote

More information

PRODUCTS: POWER SUPPLY

PRODUCTS: POWER SUPPLY PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER

More information

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC Three-phase Input Switch Mode S8PE DIN-rail mounting, 3-phase input Switch mode Supply with a range of 5A to 40A output current 3 phase 400/480 or 200/230 VAC input 5, 10, 20 and 40A; 24 VDC output Higher

More information

Relays & Sockets. RQ Series PCB Relays

Relays & Sockets. RQ Series PCB Relays RQ RQ Series PCB Relays IDEC RQ relays are low-profile, PCB relays in a compact package. Size equals value. RQ relays are small, yet maintain high contact ratings and long operational life. For larger

More information

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series Industrial Automation Catalog Section - U906 Relays Selection Guides General Purpose Relays RU Series RR Series For up-to-date information, or to request a full copy of this catalog, contact us at www.idec.com

More information

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet Combined Power Supply & Battery Charger Data Sheet INTRODUCTION UCS-CHR24V55W is a combined charger and power supply with dedicated outputs for both charging and power supply. With a large input range

More information

RoHS-Compliant Brushless Motor Systems FBL Series. Features

RoHS-Compliant Brushless Motor Systems FBL Series. Features Speed Control Systems RoHS-Compliant Brushless Motor Systems FB Series The FB Series consists of a high performance, compact, brushless motor and driver. This product is available with 75 W (1/1 HP) and

More information

POWER-WIN TECHNOLOGY CORP.

POWER-WIN TECHNOLOGY CORP. FEATURES Medical 60601-1 3.1 rd Edition approved U-Channel, End fan and Top fan types available Optional high efficiency OR-ing FET diode Current share function 2 year warranty ELECTRICAL SPECIFICATIONS

More information

General Purpose Relay

General Purpose Relay General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)

More information

TDK-Lambda ZWS240BP/A SPECIFICATIONS

TDK-Lambda ZWS240BP/A SPECIFICATIONS SPECIFICATIONS A253-1-1/A-B MODEL ZWS24BP ZWS24BP ZWS24BP ITEMS -24/A -36/A -48/A 1 Nominal Output Voltage V 24 36 48 2 Average Output Current A 1 6.7 5. 3 Peak Output Current (*1) A 2. 13.4 1. 4 Average

More information

Terminal Blocks. Selection Guide. Selection Guides. P-2 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC

Terminal Blocks. Selection Guide. Selection Guides. P-2  USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC Selection Guide Key features of IDEC terminal blocks included: Molded from UL94-V0 material with excellent flame- and shock-resistance Mount on a standard 1.38" (35mm) DIN rail Marking strips and dust

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Plastic Bezel Metal Bezel Ø 40mm Pushlock Turn Reset 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* 2NC HW1X-BV402-R* HW4X-BV402-R*

More information

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Section. Circuit Breakers   Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series... Section Selection Guide...-2 RA Series...-3 RBM Series...-3 RC Series...-20 General Instructions...-29 Internal Circuit Overview...-29 for more information on this product family visit www.idec.com/circuitbreaker

More information

A22NK. Key-type Selector Switches

A22NK. Key-type Selector Switches Key-type Selector Switches -mm dia. Key-type Selector Switches Control panel miniaturization through a more compact design and modified wiring direction. Addition of Push-In Plus terminal blocks for easy

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

D R C- 4 0 s e r i e s

D R C- 4 0 s e r i e s LPS Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 Features Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Battery low protection /

More information

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada Key features: SPDT through PDT, 0 contacts Midget power type relays vailable in pin and blade terminal styles. Options include an indicator, check button for test operations and side flange. Series Power

More information

Terminal Blocks. BNH/BN Terminal Blocks. BNH/BN Series. Specifications. USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC P-3

Terminal Blocks. BNH/BN Terminal Blocks. BNH/BN Series. Specifications.  USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC P-3 BNH/BN BNH/BN Series Key features of the BNH/BN series include: Touch-down terminals with spring-loaded captive screws available Jumpers available up to 30A model Fuse block with or without blown-fuse

More information

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements. Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high

More information

Surface mounting, flush mounting, and DIN track mounting

Surface mounting, flush mounting, and DIN track mounting Solid-state Timer H3JA Economical, Compact, Plug-in Timer Time limit, ON-delay, operation with automatic resetting. DIN size (36 x 36 mm), fits standard 8-pin sockets. Wide choice of supply voltages: 24,

More information

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz Miniature Magnetic Latching Key features of the RY2L series include: Standard ice cube, 14-pin solder lug termination Operates by pulse input and maintains condition even during power failure Coils rated

More information

Industrial Relay KML(1C, 2C)

Industrial Relay KML(1C, 2C) Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_2_2 Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting possible

More information

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed PCB Relay G5LA A Cubic, Single-pole 1A Power Relay Economical cube relay with universal terminal footprint Conforms to VDE435, CQC UL recognized/ CSA certified. High switching power: 1A @ 5VAC Withstands

More information

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB ø22mm XW E-Stops Circuit Breakers Terminal Blocks ors Timers elays & Sockets Signaling ights 22mm XW E-Stops Key features: The depth behind the panel can be as little as 46.4 mm for 1 to 4 contacts (with

More information

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating ECP180 Series Low 1 Profile High Power Density 2.0 by 4.0 Footprint 120W Convection-cooled Rating 180W Force Cooled Rating Medical & ITE pprovals Class I and Class II pplications High Efficiency, up to

More information

DC/DC converters - MINI-PS DC/ 5-15DC/

DC/DC converters - MINI-PS DC/ 5-15DC/ Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

Model Number Structure

Model Number Structure Solid State Relays Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting possible for linking

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil 2, 3 or 4 C/O contacts Switching performance up to 3000 VA Relay height 29 mm Cadmium-free contact material Mechanical indicator Manual test tab, optionally lockable. White marking tabs Applications Universal

More information

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute) RSS Series Panel Mount Solid State Relays Key features of the RSS series include: Photo isolation 1,200 volt blocking voltage 4,000 volt optical isolation Zero voltage turn-on 100% tested at rated current

More information

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms

More information

AC Motor Systems US Series

AC Motor Systems US Series US Series The US Series combines a control unit and an AC speed control motor. Connection between the motor and control unit is simplified by an easy-to-use connector. The US Series is designed for applications

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

Isolated and rugged 24 Vdc power for battery powered electronic control systems on rail equipment

Isolated and rugged 24 Vdc power for battery powered electronic control systems on rail equipment TECHNICAL DATASHEET #TDAX083200 Isolated 110Vdc/24Vdc Converter 110V, 96V or 72Vdc Nominal Input Optional Enable Input 24Vdc Output, 240W P/N: AX083200 or AX083201 or AX083202 Isolated and rugged 24 Vdc

More information

GB60S 60W Single Output General Purpose Series

GB60S 60W Single Output General Purpose Series Features 2 x 3 x 1.0 Package Operates to 80 C Ambient For 1U Applications 60W convection cooled Universal Input 90-264Vac Optional Power ON LED Approved to CSA/EN/IEC/UL60950-1, 2 nd Edition Efficiency

More information

Section. Terminal Blocks Selection Guides...P-2

Section. Terminal Blocks   Selection Guides...P-2 Section Selection Guides...-2 General urpose BN/BNH Modular Terminal & Fuse Blocks............... -3 BN High Current ower Blocks.. -7 BA One iece Terminal/Fuse Blocks & Small Current ower Blocks.. -9 BX

More information

Brushless DC Motor Systems FBL2 Series

Brushless DC Motor Systems FBL2 Series FBL2 Series The FBL2 Series consists of a high performance, compact, brushless DC motor and driver. This product is available with 75 W (1/1 HP) and 12 W (1/6 HP) output power. For easy installation, the

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

Lexium integrated drives

Lexium integrated drives Description ILp for CANopen, PROFIBUS DP, RS ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for CANopen DS, PROFIBUS DP or RS and a brushless DC motor.

More information

22mm XW E-Stops. UL File #E68961 CCC No Specifications

22mm XW E-Stops. UL File #E68961 CCC No Specifications XW Series 22mm XW E-Stops Key features: The depth behind the panel is only 48.7 mm for 1 to 4 contacts (with terminal cover) for illuminated and non-illuminated units. IDEC s original Safe break action

More information

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W 2019-V1.0-0318 Specifications AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W No. 545 Museum Road Yangzhou, Jiangsu China 225009 Tel: 86 (514) 8279 1592 Fax: 86 (514) 8769 3159 2019 AC-DC Din Rail

More information

ø22mm HW Series Control Units Control Units

ø22mm HW Series Control Units Control Units mm HW Series Control Units Control Units HW Series Control Units (Selection Guide) Function Emergency Stop Switch (Unibody Type) Emergency Stop Switch (Separate Type) Pushlock Turn eset Category ø40mm

More information

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase) SRPH1 Series Single Phase, Analog Input Type SSR Features Power control/ Cycle control/phase control (fixed cycle/ variable cycle) are available with 4-mA analog input Superior dielectric strength : 4,000VAC

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

TDK-Lambda ZWS300BAF/A

TDK-Lambda ZWS300BAF/A ZWS3BAF/A SPECIFICATIONS A254-1-1/A-B MODEL ZWS3BAF ZWS3BAF ZWS3BAF ZWS3BAF ZWS3BAF ITEMS -12/A -15/A -24/A -36/A -48/A 1 Nominal Output Voltage V 12 15 24 36 48 2 Maximum Output Current A 25.. 12.5 8.4

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

DBC-1 DEIF Battery Charger

DBC-1 DEIF Battery Charger DBC-1 DEIF Battery Charger INSTALLATION INSTRUCTIONS 12/24 V-5/10 A-115/230 V High MTBF > 60,000 h at 70 C Temp. range -25 C to +70 C Overvoltage protected Boost/equalisation functionality Failure alarm

More information

Switching Power Supplies

Switching Power Supplies , 18 150 Watt Features Compact boxed power supplies with screw terminal block Universal input 85-264 VAC, 50/60 Hz Short circuit and overvoltage protection High efficiency International safety approvals

More information

Open Frame Power Supplies

Open Frame Power Supplies , 0 300 Watt Features Small and compact PCB Construction Optional with Chassis and Cover Universal Input 8 264 VAC, Output Voltage adjustable Compliance to E 6000-3-2 (PFC) EMI meets E022, Class B and

More information

S8VK-S (30/60/120/240/480-W Models)

S8VK-S (30/60/120/240/480-W Models) New Product Switch Mode Power Supply S8VK-S (3/6/1/2/48-W Models) A Perfect Fit for Small Control Panels Coated PCBs for Better Resistance to Environment Connections for Easy Wiring Operation possible

More information

POWER-WIN TECHNOLOGY CORP.

POWER-WIN TECHNOLOGY CORP. atts Dual to Quad Output FEATURES Build-in active PFC function, PF > 0.9 Compact design for multiple outputs Dual to Quad output, Flexible DC output combination from 3.3V to 48V 2 year warranty ELECTRICAL

More information

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm Power Relays RL Series PRODUCT DESCRIPTION Quick Connect Flange Mount SPECIFICATIONS Number of poles pole 2 poles Contact Configuration X (SPST, double make) 2X (DPST, double make) Contact material Ag

More information

LS200 Series Instruction Manual

LS200 Series Instruction Manual LS200 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage may lead to an electrical shock, damage to the unit

More information

RWS50B RWS100B RWS150B RWS300B RWS600B

RWS50B RWS100B RWS150B RWS300B RWS600B RWS-B Series 50W to 600W Single Output General Purpose Power Supplies Features 10 Year e-cap Lifetime 7 Year Warranty Global Safety Approvals Compact Size Better Field Reliability Lower Cost of Ownership

More information

Lexium integrated drives

Lexium integrated drives Description ILp for DeviceNet, EtherCAT, Modbus TCP, ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for DeviceNet, EtherCAT, Modbus TCP or and a brushless

More information

Totally Sealed Hour Meter

Totally Sealed Hour Meter Totally Sealed Pictures not shown to scale for clarity The Redington Model 711/731 provides a family of compact 7 figure, AC or DC s. The totally sealed case protects against the environment and provides

More information

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F 8H Type List 8H Terminal style Contact form Features Miniature PCB Power Relays A 2VAC. High CTI 2 material or product comply with IEC 33-1 are available. UL Insulation Class F. VDE, UL/CUL, TUV, CSA/CUS

More information

This document provided by Barr-Thorp Electric Co., Inc

This document provided by Barr-Thorp Electric Co., Inc Switching & Controls For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos & upgrades Part confi

More information

Ordering Information. Text PCB Power Relay G5LE

Ordering Information. Text PCB Power Relay G5LE A Cubic, Single-pole 10-A Power Relay Single-pole 10A 35VDC, 0.8mm contact gap: G5LE-G Single-pole 16A 250VAC: G5LE-E ROHS compliant. Sub-miniature sugar cube relay with universal terminal footprint. Conforms

More information

Relays & Sockets. RV8 Series 6mm Interface Relays. (when using combination of RV relay and SV socket) RV8H Electromechanical Part Numbers

Relays & Sockets. RV8 Series 6mm Interface Relays. (when using combination of RV relay and SV socket) RV8H Electromechanical Part Numbers RV8 Series 6mm Interface Relays Key features: Class I, Division 2 and Class I, Zone 2 Hazardous Location options (electromechanical relays only) Solid State relay versions available Only 70mm in height

More information

Terminal Blocks. Switching & Controls.

Terminal Blocks. Switching & Controls. Switching & Controls Selection Guides... 1006 General Purpose... 1007 BN/BNH Modular & Fuse Blocks.. 1007 BN High Current Power Blocks... 1011 BA One Piece /Fuse Blocks & Small Current Power Blocks...

More information

AC Motor Systems. Speed Control Systems B-137. Speed Control Systems Introduction. BHF Series FE200 ES01/ US Series

AC Motor Systems. Speed Control Systems B-137. Speed Control Systems Introduction. BHF Series FE200 ES01/ US Series AC Motor Systems Speed Control Systems Introduction BHF Series FE1/FE2 ES1/ES2 US Series FB FE1/ FE2 ES1/ ES2 US Installation Page BHF Series B-138 FE1/FE2 B-156 ES1/ES2 B-172 US Series B-22 B-137 RoHS-Compliant

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number: INSTRUCTION MANUAL FOR VOLTAGE REGULATOR Model: APR 125-5 Part Number: 9 1688 00 100 Publication Number: 9 1688 00 990 Revision H: 07/2001 CONTENTS SECTION 1 GENERAL INFORMATION...1-1 DESCRIPTION... 1-1

More information

DRB-1 Series Instruction Manual

DRB-1 Series Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1 Motor Timer H2A Miniature, High-performance Motor Timer Employs high-reliability bifurcated contacts for output. Moving pointer provided in all types for confirmation of elapsed time. Employs time-out

More information

Model Number Structure

Model Number Structure Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action

More information

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m) Installation Instructions D24-53 Issue Date November 4, 23 D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m) Installation IMPORTANT: The D24-53 Series actuator is intended to control

More information

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil

More information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty

More information

55 Series - Miniature General Purpose Relays 5-10 A

55 Series - Miniature General Purpose Relays 5-10 A Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A Main Feature 1. 1 Pole to 4-Poles versions available with switching current at 15A (1 Pole) and 10A (2-4 Poles). 2. Printed Circuit Board Terminal, Plug-in Terminal and Flanged Case are designed for easy

More information

ZWD100PAF. Conformity to RoHS Directive

ZWD100PAF. Conformity to RoHS Directive -SERIES Dual Output W - 225W Features 15 Complies the standard of the harmonics current limiter Worldwide input: 85-265VAC Peak load accommodatable double power: Approximately twice the value of average

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: Two button sizes: ø29 and ø4mm ead-free, ohs compliant, (EU directive 22/95/EC) Depth behind the panel: Standard - only 27.9mm for 1 to 4 contacts Unibody - only 23.9mm for 1NC or 2NC IDEC

More information

MD60 Series 60W DINergy Power Supply

MD60 Series 60W DINergy Power Supply MD60 Series 60W DINergy Power Supply Features Compact size, high efficiency and DIN Rail mounting 60 C rated provides full power/no derating required 100-240VAC wide-range auto-selection input Overcurrent,

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

Scheda prodotto Relè Series B

Scheda prodotto Relè Series B Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where

More information