1 Magnetic Overcurrent Circuit Breaker Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically separate excitation and switching circuits, and one pair of auxiliary contacts which close when the main circuit is open. Also suitable for impulse operation. Designed for printed circuit board mounting. Low temperature sensitivity. Typical applications Printed circuit boards and components, safety and control systems. 808 Ordering information Technical data Type No. 808 fast-acting Manual release (optional) H manual release facility Current ratings A H - A ordering example Standard current ratings and typical internal resistance values Current Internal Current Internal rating (A) resistance (Ω) rating (A) resistance (Ω) Approvals Authority Voltage ratings Current ratings CSA AC 0 V, DC 60 V A UL DC 60 V A AC 0 V A Voltage rating Current ratings Max. continuous load excitation circuit (-) Max. continuous load switching circuit 6-7 auxiliary circuit 4- Typical life Ambient temperature DC 4 V (higher voltages to special order) UL: AC 0 V, DC 60 V A (higher current ratings to special order).6 x I N A 6,000 operations at A for switching circuit C ( F) Insulation co-ordination rated impulse pollution (IEC ) withstand voltage degree. kv Dielectric strength (UL 77) test voltage operating area AC,40 V excitation to switching circuit AC,40 V excitation to auxiliary circuit AC,40 V Insulation resistance > 0 MΩ (DC 00 V) Interrupting capacity (o-o-o) 0 A Interrupting capacity (UL 77) Degree of protection (IEC 609/DIN 4000) Vibration Shock Corrosion Humidity Mass,000 A AC 0 V,000 A DC 60 V operating area IP0 terminal area IP00 g (7-00 Hz), ±0. mm (-7 Hz), to IEC , test Fc frequency cycles/axis g ( ms) to IEC , test Ea 48 hours at % salt mist, to IEC , test Ka 40 hours at 9 % RH to IEC , test Cab approx. g 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

2 Magnetic Overcurrent Circuit Breaker Dimensions Internal connection diagram ON ø9..66 ø : excitation circuit 6-7: switching circuit 4-: auxiliary circuit H. ON ø9..66 ø Typical time/current characteristics at + C/+7.4 F Trip time in milliseconds times rated current All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 76 Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

3 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G... Description ngle, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or HM CBE to EN 6094) ensures suitability for a wide range of applications. Convenient threadneck panel or plug-in mounting, and with a white push button indicator band showing clearly the tripped/off position. Available with auxiliary contacts ( x N/O, x N/C) for status signalling and fitted with an unprotected shunt tap terminal as standard. Approved to CBE standard EN 6094 (IEC 6094). Typical application Control equipment, communications systems, power semiconductors. 840-G... pole pole Standard current ratings and typical internal resistance values Current Internal resistance (Ω) per pole rating (A) curve curves curves -F4/F -E/H/R -E/H/R < < < < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < < 0.0 < 0.0 < < 0.0 < 0.0 < 0.0 < 0.0* < 0.0 < < 0.0* < 0.0 < < < 0.0 * 0 % ON duty / 60 min. Approvals Authority Voltage ratings Current ratings VDE (EN 6094) AC 4 V, AC 40 V, DC 80 V A DC 80 V A single pole UL 77, CSA DC 80 V A + pole AC 0 V; AC 0 V A,, pole UL 489 A DC 80 V A + pole BV AC 0 V, DC 6 V A Technical data Voltage rating AC 4 V; AC 40 V, 0/60 Hz; DC 80 V Current ratings A single pole (40+0 A DC only) A multipole Auxiliary circuit A, AC 40 V/DC 6 V; 0. A, DC 80 V Typical life pole:,000 operations at x I N 40+0 A,000 operations at xi N and pole:,000 operations at x I N Ambient temperature C ( F) Insulation co-ordination rated impulse pollution (IEC and 60664A) withstand voltage degree. kv reinforced insulation in operating area Dielectric strength (IEC and 60664A) test voltage operating area AC,000 V pole to pole ( + pole) AC,00 V main to auxiliary circuit AC,00 V aux. circuit -/-4 AC,000 V switching to trip circuit (-X) AC,00 V Insulation resistance > 0 MΩ (DC 00 V) Interrupting capacity I cn,00 A at AC;,000 A at DC Interrupting capacity I N A...0 A (UL 77) AC: pole AC 0 V/,00A AC 0 V/,00A pole AC 0 V/,00A AC 0 V/,000A pole AC 0V/,00A AC0V/,000A DC: pole A DC 80 V/,00 A pole A DC 80 V/00 A Interrupting capacity (UL 489A) 000 A Degree of protection operating area IP40 (IEC 609/DIN 4000) terminal area IP00 Vibration with button down: g (7-000 Hz), ±0.76 mm (-7 Hz) at 0.9 x I N other mounting planes: g (7-000 Hz) at I N to IEC , test Fc frequency cycles/axis Shock 0 g ( ms) at xi N, directions,,,4, 0 g ( ms) at 0.8 x I N, direction 6 to IEC , test Ea Corrosion 96 hours at % salt mist, to IEC , test Ka Humidity 40 hours at 9 % RH to IEC , test Ca Mass approx. 70 g per pole 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

4 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G... Ordering information Type No. 840 Magnetic push/pull circuit breaker Mounting G threadneck panel mounting Threadneck design Mx Number of poles (main current paths) 0 single pole, switch only single pole, protected two pole, protected three pole, protected two pole, protected on one pole only Panel hardware 0 without panel hardware with hex nut Mx and washer / Terminal design P blade terminals A6.-0.8mm (QC.0) N blade terminals A6.-0.8mm (QC.0) with -A terminal (blade terminal) A6.-0.8mm (QC.0) G screw terminals M4* with -A terminal (blade G4 screw terminals M* } terminals) A6.-0.8mm (QC.0) K screw terminals M4* K4 screw terminals M* R round connectors ø6 X blade terminals A6.-0.8mm (QC.0), separate switching and trip circuit Kennlinie F4 instantaneous trip: magn..-.xi N DC (I N 0 A) F magn..-.7xi N AC 0/60 Hz (I N 0A) E short delay: magn.-hydr I N, DC E short delay: magn.-hydr I N, AC 0/60 Hz H medium delay: magn.-hydr I N, DC H medium delay: magn.-hydr I N, AC 0/60Hz R long delay: magn.-hydr..0-. I N, DC R long delay: magn.-hydr.0-. I N, AC0/60Hz Actuator colour A black with white trip indicator band Actuator marking 0 without marking 4 rated current (legible with location pin below) standard 7 rated current (legible with location pin above) Auxiliary contacts H0 without auxiliary contacts H with auxiliary contacts H with auxiliary contacts on pole only ( and pole types) H with auxiliary contacts on poles and ( pole type) Auxiliary contact function one each N/O and N/C pair N/O (/4) pair N/C (/) Auxiliary contact terminal design blade terminals A mm Current ratings (optional) A Approval (optional) U UL 489 A G - N F4 - A 4 H - 8 A - U ordering example Dimensions ( pole) Terminal design -N tightening torque max. 4 Nm Mx x6.8 6x current rating in A SW4. blade terminal A (QC.0) to DIN 4644 location pin for mm (.8 in.) hole dia ON..7.6 ø8.4. black white x blade terminal A x.68 (QC.0) to DIN Terminal design -G/-K Terminal design -R (i) 4 (k) ø.6.47 terminal M4 or M tightening torque max.. Nm *.764 panel thickness max. mm (.8 in.) * min. for use with splash cover mounting hole 9. ±0..74 ± ø ø *M4 thread recommended for I N > 0 A M thread for I N > 40 A 78 Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

5 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G... Dimensions ( pole) Dimensions ( pole) Internal connection diagrams pole, protected magnetically line multipole line unit (i) 4 (k) (k) (i) 4 (k) pole, protected hydraulic-magnetically unit line (i) 4 unit unit Cut-out dimensions: pole unit unit min. 40 min..7 min. 60 min..6 unit panel thickness max. mm (.8 in) (i) 4 (k) Circuit variants pole line 4 (i) (k) (k) unit (i) 4 (k) 840-G-XF4-A4H- A - switching circuit (i) - (k) magnetic trip circuit - 4 auxiliary circuit (N/O) pole line Installation drawings (i) (k) 840-G-XF4-A4H- A - switching circuit (i) - (k) magnetic trip circuit - auxiliary circuit (N/C) Terminal design -N / -P Terminal design -G / -K Shock directions / Mounting attitudes operating area (reinforced insulation) mounting area Terminal design -R 4 Line terminal area /0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

6 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G... Typical time/current characteristics Curve F4 for DC, magnetic (undelayed) (I N >0 A, 0% ON period, 60 min.) at + C / +7.4 F Curve F for AC 0/60 Hz, magnetic (undelayed) (I N >0 A, 0% ON period, 60 min.) at + C / +7.4 F Short delay curves E for DC and E for AC 0/60 Hz, hydraulic-magnetic Medium delay curves H for DC and H for AC 0/60 Hz, hydraulic-magnetic Long delay curves R for DC and R for AC 0/60 Hz, hydraulic-magnetic N.B. Curves E, E, H, H, R and R will only be maintened if the escutchen is mounted on a vertical surface. Other curves upon request ( e. g. impulse delay). 80 Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

7 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G... Accessories Socket 8-P- (for ratings >6 A please contact E-T-A) polarization recess retaining clip (accessory) top-hat rail EN 00-x7. Polarized socket with adapter 8-P--00 blade terminal A (QC.0) to DIN 4644 polarized to ensure correct connection mm.94 in. depth adapter X Bus bar (-way) (supplied as a complete package) for type 8 socket (for max. 0 A continuous load), more positions available on request X 8 0 with terminal X 8 0 without terminal Phoenix terminal AKG cross section max mm (AWG ) cylinder-head screw M4x4 ISO 07 nickel-plated G profile EN 00-G washer A4. DIN nickel plated female connector Hex nut Y Mx SW Accessories for push button Splash cover with hex nut and O ring (IP66) X (nickel plated hex nut Mx, splash cover transparent) X (black finish hex nut Mx, splash cover black) SW 7 Mx Spring washer Y Splash seal, black, hex nut and O ring (IP4) X (nickel plated hex nut Mx, splash seal black).±0. ø ± ø.9 thickness 0.4 mm.06 in M4 copper rail tin-plated SW Insulated sleeving for bus bars Y fusible link (constriction mm/.09 in. thick) Actuator extension X (black button).94 Retaining clip for socket 8-P- Y mounting dimensions ø Connector bus link -P X 88 0/. mm (AWG 6), brown (up to A max. load) X 88 0/. mm (AWG 4), black (up to 0 A max. load) X 88 0/. mm (AWG 4), red (up to 0 A max. load) X 88 04/. mm (AWG 4), blue (up to 0 A max. load) 0 quick-connect tabs 6. (.0) DIN 4647 tinned brass, insulated ~70 ~.76 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

8 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G... V Description ngle and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or HM CBE to EN 6094) ensures suitability for a wide range of applications. Convenient threadneck panel or plug-in mounting, and with a white push button indicator band showing clearly the tripped/off position. Available with auxiliary contacts ( x N/O, x N/C) for status signalling and fitted with an unprotected shunt tap terminal as standard. Reliable tripping with even the smallest overcurrents. Approved to CBE standard EN 6094 (IEC 6094). Typical application Railway vehicles, telecommunications, process control. Standard current ratings and typical internal resistance values Current Internal resistance (Ω) per pole rating (A) curve -F4 curves -E/H/R < < < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < < 0.0 < < 0.0 < 0.0 < 0.0* < < 0.0* < < < 0.0 * 0 % ON duty / 60 min. Technical data 840-G... V DC pole pole Voltage rating DC V ± % Current ratings A single pole A pole Auxiliary circuit AC 40 V/DC 6 V A DC V ± % 0, A Typical life pole:,000 operations at x I N 40+0 A,000 operations at xi N pole:,000 operations at x I N Ambient temperature C ( F) Insulation co-ordination rated impulse pollution (IEC and 60664A) withstand voltage degree. kv reinforced insulation in operating area Dieelectric strength (IEC and 60664A) test voltage operating area AC,000 V pole to pole ( pole) AC,00 V main to auxiliary circuit AC,00 V aux. circuit -/-4 AC,000 V switching to trip circuit (-X) AC,00 V Insulation resistance > 0 MΩ (DC 00 V) Interrupting capacity I cn,000 A Degree of protection operating area IP40 (IEC 609/DIN 4000) terminal area IP00 Vibration with button down: g (7-000 Hz), ±0.76 mm (-7 Hz) at 0.9 x I N other mounting planes: g (7-000 Hz) at I N to IEC , test Fc frequency cycles/axis Shock 0 g ( ms) at xi N, directions,,,4, 0 g ( ms) at 0.8 x I N, direction 6 to IEC , test Ea Corrosion 96 hours at % salt mist, to IEC , test Ka Humidity 40 hours at 9 % RH to IEC , test Ca Mass approx. 70 g per pole 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

9 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G... V Ordering information Type No. 840 Magnetic push/pull circuit breaker Mounting G threadneck panel mounting Threadneck design Mx Number of poles (main current paths) single pole, protected two pole, protected two pole, protected on one pole only Panel hardware 0 without panel hardware with hex nut Mx and washer / Terminal design P blade terminals A6.-0.8mm (QC.0) N blade terminals A6.-0.8mm (QC.0) with -A terminal (blade terminal) A6.-0.8mm (QC.0) G screw terminals M4* with -A terminal (blade G4 screw terminals M* } terminals) A6.-0.8mm (QC.0) K screw terminals M4* K4 screw terminals M* R round connectors ø6 X blade terminals A6.-0.8mm (QC.0), separate switching and trip circuit Characteristic curve F4 instantaneous trip: magn..0-. x I N E short delay: magn.-hydr x I N H medium delay: magn.-hydr x I N R long delay: magn.-hydr..0-. x I N Actuator colour A black with white trip indicator band Actuator marking 4 rated current (legible with location pin below) standard 7 rated current (legible with location pin above) Auxiliary contacts H0 without auxiliary contacts H with auxiliary contacts H with auxiliary contacts on pole only ( and pole types) Auxiliary contact function one each N/O and N/C pair N/O (/4) pair N/C (/) Auxiliary contact terminal design blade terminals A mm Voltage rating D DC V Current ratings A G - P H - A 4 H D - 8 A ordering example * M4 thread recommended for I N > 0 A M thread for I N > 40 A Dimensions ( pole) Terminal design -N tightening torque max. 4 Nm Mx x x Attention! LINE = (+) LOAD = (-) Terminal design -G (i) 4 (k) 6x6.8 6x current rating in A SW location pin for mm (.8 in.) hole dia Dimensions ( pole).0. ON terminal M4 or M tightening torque max.. Nm ø blade terminal A (QC.0) to DIN 4644 blade terminal A (QC.0) to DIN *.764 Terminal design -R panel thickness max. mm (.8 in.) * min. for use with splash cover 9. ±0..74 ±.008 ø8.4. black white mounting hole ø ø Cut-out dimensions: min. 40 min..7 pole unit unit panel thickness. - mm ( in.) 84 Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

10 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G... V Installation drawings Typical time/current characteristics Terminal design -N / -P Terminal design -G / -K Curve F4, magnetic (undelayed) at + C / +7.4 F Line operating area mounting (reinforced insulation) area 9.4 terminal area Short delay curve E, hydraulic-magnetic Terminal design -R Medium delay curve H, hydraulic-magnetic Internal connection diagrams pole, protected magnetically LINE LINE (i) 4 ( ) (k) LOAD pole, protected hydraulic-magnetically (i) 4 ( ) (k) LOAD pole LINE unit (i) 4 ( ) (k) LOAD LINE unit (i) 4 ( ) (k) LOAD Long delay curve R, hydraulic-magnetic N.B. Curves E, H and R will only be maintained if the escutcheon is mounted on a vertical surface. Other curves upon request (e.g. impulse delay). 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

11 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G... V Accessories Socket 8-P- (for ratings >6 A please contact E-T-A) polarization recess retaining clip (accessory) top-hat rail EN 00-x7. Polarized socket with adapter 8-P--00 blade terminal A (QC.0) to DIN 4644 polarized to ensure correct connection mm.94 in. depth adapter X Bus bar (-way) (supplied as a complete package) for type 8 socket (for max. 0 A continuous load), more positions available on request X 8 0 with terminal X 8 0 without terminal Phoenix terminal AKG cross section max mm (AWG ) cylinder-head screw M4x4 ISO 07 nickel-plated G profile EN 00-G washer A4. DIN nickel plated female connector Hex nut Y Mx SW Accessories for push button Splash cover with hex nut and O ring (IP66) X (nickel plated hex nut Mx, splash cover transparent) X (black finish hex nut Mx, splash cover black) SW 7 Mx Spring washer Y Splash seal, black, hex nut and O ring (IP4) X (nickel plated hex nut Mx, splash seal black).±0. ø ± ø.9 thickness 0.4 mm.06 in M4 copper rail tin-plated SW Insulated sleeving for bus bars Y fusible link (constriction mm/.09 in. thick) Actuator extension X (black button).94 Retaining clip for socket 8-P- Y Shock directions / Mounting attitudes mounting dimensions ø Connector bus link -P X 88 0/. mm (AWG 6), brown (up to A max. load) X 88 0/. mm (AWG 4), black (up to 0 A max. load) X 88 0/. mm (AWG 4), red (up to 0 A max. load) X 88 04/. mm (AWG 4), blue (up to 0 A max. load) 0 quick-connect tabs 6. (.0) DIN 4647 tinned brass, insulated ~70 ~.76 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 86 Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

12 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-F... Description ngle and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or HM CBE to EN 6094) ensures suitability for a wide range of applications. Industry standard dimensions and panel mounting. Options include auxiliary changeover contacts, or relay trip function. Low temperature sensitivity at rated load. Approved to CBE standard EN 6094 (IEC 6094). Typical applications Control equipment, communications systems, transportation, power supplies. Standard current ratings and typical internal resistance values Current Curves and internal resistance per pole (Ω) rating (A) F F K, M, T, K, M, T < < 0.0 < < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < < 0.0 < 0.0 < 0.0 < < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < < 0.0 < 0.0 < 0.0 < Approvals Authority Voltage ratings Current ratings VDE (EN 6094) AC 4 V, AC 40 V, DC 80 V A DC 80 V A pole UL 77, CSA DC 80 V A + pole AC 0 V, AC 0 V A,, pole UL 489 A DC 80 V A + pole BV AC 0 V, DC 6 V A QPL (Sweden) AC 40 V, DC 0 V...0 A Technical data 840-F... pole pole Voltage rating AC 4 V; AC 40 V, 0/60 Hz; DC 80 V (higher DC ratings to special order) Current ratings A pole ( A DC only) A multipole Auxiliary circuit 6 A, AC 40 V/DC 8 V A, DC 6 V 0. A, DC 80 V Typical life,000 operations at x I N pole: 40+0 A,000 operations at xi N Ambient temperature C ( F) Insulation co-ordination rated impulse pollution (IEC and 60664A) withstand voltage degree. kv reinforced insulation in operating area Dielectric strength (IEC and 60664A) test voltage operating area AC,000 V pole to pole ( and pole) AC,00 V main to auxiliary circuit AC,000 V switching to trip circuit AC,00 V (version -X) Insulation resistance > 0 MΩ (DC 00 V) Interrupting capacity I cn,00 A at AC,000 A at DC Interrupting capacity I N A...0 A (UL 77) AC: pole AC 0 V/,00A AC 0 V/,00A pole AC 0 V/,00A AC 0 V/,000A pole AC 0V/,00A AC0V/,000A DC: pole A DC 80 V/,00 A pole A DC 80 V/00 A Interrupting capacity (UL 489A) 000 A Degree of protection operating area IP40 (IEC 609/DIN 4000) terminal area IP00 Vibration with toggle down: g (7-000Hz) ±0.76mm (-7 Hz) at 0.9 x I N directions,,, 4, : g (7-000 Hz) at x I N. with curves F, F in all planes: g (7-000 Hz) ±0.76mm (-7 Hz) at 0.8 x I N, to IEC , test Fc frequency cycles/axis Shock 0 g ( ms) at xi N, directions,,,4, 0 g ( ms) at 0.8 x I N, direction 6. with curves F, F: 0 g ( ms) at 0.8 x I N to IEC , test Ea Corrosion 96 hours at % salt mist to IEC , test Ka Humidity 40 hours at 9 % RH to IEC , test Ca Mass approx. 6 g per pole 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

13 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-F... Ordering information Type No. 840 magnetic circuit breaker with toggle actuator Mounting F flange mounting Configuration with mounting nuts 6- UNC 4 with mounting nuts M 9 snap-in frame Number of poles 0 single pole, switch only single pole protected two pole protected } three pole protected 4 four pole protected two pole, protected on one pole only 6 four pole, protected on poles, and only 7 two pole, switch only Panel hardware 0 without panel hardware Terminal design (main contact) K screw terminals with metric thread, M4 (recommended for I N 0 A) K4 screw terminals with metric thread, M (I N = 40 A) P blade terminals X blade terminals with separate switching and relay circuit Characteristic curves Characteristic curve F, instantaneous trip: F DC trip at.0-. x I N F AC 60/0Hz trip at.0-. x I N haracteristic curve K, short delay: K DC trip time at x I N : s K AC 60/0Hz trip time at x I N : s Characteristic curve M, medium delay: M DC trip time at x I N : s M AC 60/0Hz trip time at x I N :.-0 s Without characteristic curve: Q0 switch only Characteristic curve T, long delay: T DC trip time at x I N : -70 s T AC 60/0Hz trip time at x I N : -0 s Relay trip X: X voltage trip at DC, instantaneous trip X voltage trip at AC, instantaneous trip Other curves to special order (e.g. pulse delayed, high inrush currents, capacitive loads) Actuator colour / design A black, long toggle B white, long toggle K black, short toggle L white, short toggle other colours to special order Actuator marking 0 without marking EIN-AUS ON- I-O I-O side marking Auxiliary contacts H0 without auxiliary contacts H with auxiliary contacts H auxiliary contacts on one pole only (multipole) H auxiliary contacts on poles and ( and 4 pole) G as H, but contacts gold plated G as H, but contacts gold plated G as H, but contacts gold plated Auxiliary contact function 4 change over contact Auxiliary contact terminal design blade terminal.8-0. mm F 0 - P M - A H magnetic, hydraulic-magnetic F 0 - P M - A H Current ratings A Voltage rating only curves X, X DC, 8,, 4 V AC, 0, 40 V Approval (optional) U UL 489 A F 0 - P M - A H 4-0A - U ordering example Innenschaltbilder pole protected magnetically line line 4 unit unit unit... unit 4... line line line pole protected hydraulic-magnetic multipole 4 with separate switching and relay circuit Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

14 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-F... Dimensions Dimensions long toggle unit 4 unit unit unit ON short toggle blade terminal A (QC.0) to DIN actuator marking ON- or I-O mounting thread M or 6- UNC-B mounting depth max. 4. mm/.77 in. tightening torque max. 0. Nm 6 ± Cut-out dimensions: with auxiliary contacts (6-UNC). ±0. (M).60 ± ±.004 (M) (6-UNC) with separate switching and relay circuit 840-F -X with screw terminals (recommended for I N 0) Mounting configuration 840-F ON Installation drawing operating area mounting terminal (reinforced insulation) area area ±0. Shock directions / Mounting attitudes panel cut-out.76 ± blade terminal A (QC.0) to DIN ±0..8 ± operating area mounting terminal (reinforced insulation) area area terminal M4 or M tightening torque max.. Nm 6 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

15 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-F... Typical time/current characteristics at C / +7.4 F Curve F (instantaneous) for DC Curve M0 (medium delay) for AC/DC Curve F (instantaneous) for AC 0/60 Hz Curve M (medium delay) for DC Curve K (short delay) for DC Curve M (medium delay) for AC 0/60 Hz Curve K (short delay) for AC 0/60 Hz N.B. All curves will only be maintained if the escutcheon is mounted on a vertical surface. Other characteristic curves to special order (e. g. with impulse delay for inrush peaks). 90 Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

16 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-F... Typical time/current characteristics at C / +7.4 F Accessories Curve T (long delay) for DC 000 Splash covers transparent (IP4) Y mounting holes pole ø mounting dimensions: M - hole dia.. mm/.8 in. 6- UNC-B - hole dia. 4 mm/.7 in. For pole and pole with fixing plate and screws (IP4) X 8 0 X 9 0 pole 8 pole ø fixing plate.09 fixing plate ø ±0..67 ±.004 mounting hole ± ± mounting hole 40 Fixing plate for and pole only Toggle guard Y Curve T (long delay) for AC 0/60 Hz N.B. All curves will only be maintained if the escutcheon is mounted on a vertical surface. Other characteristic curves to special order (e. g. with impulse delay for inrush peaks) x4.06x4 ø All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

17 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-T... Description ngle, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or HM CBE to EN 6094) ensures suitability for a wide range of applications. Featuring a combi-foot design for symmetric and asymmetric rail mounting. Low temperature sensitivity at rated load. Approved to CBE standard EN 6094 (IEC 6094). Typical applications Power supplies, control equipment, communication systems, EDP systems. single pole 840-T... three pole Standard current ratings and typical internal resistance values Technical data Current Curves and internal resistance per pole (Ω) rating (A) F F K, M, T, K, M, T < < 0.0 < < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < < 0.0 < 0.0 < 0.0 < < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < 0.0 < < 0.0 < 0.0 < 0.0 < Approvals Authority Voltage ratings Current ratings VDE (EN 6094) AC 4 V, AC 40 V, DC 80 V A DC 80 V A single pole UL77, CSA DC 80 V A + pole AC 0 V, AC 0 V A,, pole UL 489 A DC 80 V A + pole Voltage rating AC 4V; AC 40V (0/60Hz); DC 80V (higher DC voltages to special order) Current rating range A single pole ( A DC only) A multipole Auxiliary circuit A, AC 40 V/DC 6 V; 0. A DC 80 V Typical life,000 operations at x I N single pole: 40+0 A,000 operations at x I N Ambient temperature C ( F) Insulation co-ordination rated impulse pollution (IEC and 60664A) withstand voltage degree. kv reinforced insulation in operating area Dielectric strength (IEC and 60664A) test voltage operating area AC,000 V pole to pole AC,00 V main to aux. circuit AC,00 V Insulation resistance > 0 MΩ (DC 00 V) Interrupting capacity I cn,00 A at AC,000 A at DC Interrupting capacity I N A...0 A (UL 77) AC: pole AC 0 V/,00A AC 0 V/,00A pole AC 0 V/,00A AC 0 V/,000A pole AC 0V/,00A AC0V/,000A DC: pole A DC 80 V/,00 A pole A DC 80 V/00 A Interrupting capacity (UL 489A) 000 A Degree of protection operating area IP40 (IEC 609/DIN 4000) terminal area IP0 Vibration with toggle down: g at 0.9 I N directions,,,4,: g at x I N with curves F, F: g at 0.8 x I N in all planes. (7-000 Hz) ±0.76 mm (-7 Hz) to IEC , test Fc frequency cycles/axis Shock 0 g ( ms) at x I N, directions,,,4, 0 g ( ms) at 0.8 x I N, direction 6 with curves F, F: 0 g ( ms) at 0.8 x I N to IEC , test Ea Corrosion 96 hours at % salt mist, to IEC , test Ka Humidity 40 hours at 9 % RH, to IEC , test Ca Mass approx. 98 g per pole 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

18 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-T... Ordering information Type No. 840 circuit breaker with toggle actuator Mounting T rail mounting Configuration snap-on installation Number of poles 0 single pole, switch only single pole protected two pole protected three pole protected } magnetic, hydraulic-magnetic 4 four pole protected two pole, protected on one poly only 6 four pole, protected on poles, and only 7 two pole, switch only Panel hardware 0 without panel hardware Terminal design (main contact) K recessed screw/pressure plates M4 Characteristic curve Curve F, instantaneous trip: F DC trip at.0-. x I N F AC 60/0Hz trip at.0-. x I N Curve K, short delay: K DC trip at x I N 0.6-.s K AC 60/0Hz trip at x I N 0.-.6s Curve M, medium delay: M DC trip at x I N s M AC 60/0Hz trip at x I N.-0 s Without characteristic curve Q0 switch only Curve T, long delay: T DC trip at x I N -70s T AC 60/0Hz trip at x I N -0s Other characteristic curves to special order (e.g. pulse-delayed, high inrush currents, capacitive loads) Actuator colour / design A black, long toggle B white, long toggle K black, short toggle L white, short toggle other colours to special order Marking on housing top surface E I-O and ON- F I-O and ON- and current rating, voltage, curve and connection diagram Auxiliary contacts H0 without auxiliary contacts H with auxiliary contact H with auxiliary contact on one pole only (multipole) Auxiliary contact function (see internal connection diagrams) N/O contact N/C contact Auxiliary contact terminal design 6 screw/pressure plate M Current ratings A Approval (optional) U UL 489 A T 0 - K M - A E H 6 - A - U ordering example Dimensions long toggle slot for fitting labels from Phoenix unit III unit II unit I LINE short toggle LINE ON LOAD Snap-in socket for: G profile EN 00-G top-hat rail EN 00-x7. EN 00-x/ ON Installation drawing operating area (reinforced insulation) 0 LOAD min. min.09 mounting area pole pole pole auxiliary contact terminal M tightening torque max. 0. Nm wire section max.. mm (AWG 4) main contact terminal M4 tightening torque. Nm wire section max.: 0.7 mm rigid conductor ( AWG 8 AWG 8) mm flexible conductor ( AWG 8 AWG ) min. 8 min LINE 7.. LOAD terminal area 94 Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

19 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-T... Internal connection diagrams Typical time/current characteristics at C / +7.4 F pole protected magnetically line line N/C H or N/O H pole protected hydraulic-magnetically or Optional N/C or N/O auxiliary contact () multipole line or or unit I unit II unit III... unit IV... Curve T (long delay) for DC Curve T (long delay) for AC 0/60 Hz Shock directions N.B. All curves will only be maintained if the escutcheon is mounted on a vertical surface. Other characteristic curves to special order (e. g. with impulse delay for inrush peaks). AUX AUX Accessories Connector bus links -K X 89 0/. mm, (AWG 4) (black) up to 0 A max. load X 89 0/. mm, (AWG 6) (brown) up to A max. load 0 pin lugs to DIN 460 tinned copper ø..099 ~70 ~.76 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

20 Magnetic and Hydraulic-Magnetic Circuit Breaker 840-T... Typical time/current characteristics at C / +7.4 F Curve F (instantaneous) for DC Curve M0 (medium delay) for AC/DC Curve F (instantaneous) for AC 0/60 Hz Curve M (medium delay) for DC Curve K (short delay) for DC Curve M (medium delay) for AC 0/60 Hz Curve K (short delay) for AC 0/60 Hz N.B. All curves will only be maintained if the escutcheon is mounted on a vertical surface. Other characteristic curves to special order (e. g. with impulse delay for inrush peaks). 96 Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

21 Magnetic and Hydraulic-Magnetic Circuit Breaker Description ngle or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications. Industry standard dimensions and panel mounting. Auxiliary contacts optional. Low temperature sensitivity at rated load. Approved to CBE standard EN 6094 (IEC 6094) S-type HM CBE. NEW Typical applications In the business fields Communication and Transport: power supplies, switchgear, instrumentation and process control engineering. 84 pole pole Standard current ratings and typical internal resistance values Current Trip curves and internal resistance (Ω) per pole rating (A) K, M, T, K, M, T < 0.0 < 0.0 < 0.0 < < 0.0 < 0.0 < 0.0 < < 0.0 < < 0.0 < < 0.0 < < 0.0 < < 0.0 < < 0.0 < 0.0 < 0.0 < 0.0 Interrupting capacity to EN 6094, UL 489 and UL 77 IEC 6094 test series E voltage number of poles I N max. (A) I cn (A) DC 80 V ,000 DC 80 V ,000 AC 40 V ,000 AC 40/4 V (4) ,000 UL 489 test sequence Z voltage number of poles I N max. (A) I cn (A) DC 80 V ,000 DC 80 V ,000 AC 0 V ,000 AC 40 V ,000 AC 0/40 V () ,000 Technical data Voltage rating AC 4 V; AC 77/480 V; AC 0/40 V; AC 40 V; DC 80 V, Current rating range A single and multipole A single pole, two poles connected in parallel higher ratings upon request Auxiliary circuit AC 40 V/DC 8 V 6 A DC 6 V A; DC 80 V 0. A Typical life,000 operations at x I N Ambient temperature -40 C...+8 C ( F) Insulation co-ordination (IEC 60664) Dielectric strength operating area pole to pole main to auxiliary circuit switching to trip circuit. kv/ reinforced insulation in operating area test voltage AC 000 V AC 00 V AC 00 V AC 00 V Insulation resistance > 0 MΩ (DC 00 V) Degree of protection operating area IP40 (IEC 609) terminal area IP00 Vibration with toggle down: g (7-000 Hz) ±0,76mm (-7Hz) at 0.9 I N directions,,,4,: g at x I N with curves F, F: g at 0.8 x I N in all planes. (7-000 Hz) ±0.76 mm (-7 Hz) to IEC , test Fc frequency cycles/axis Shock directions,,,4,: 0 g ( ms) at x I N, direction 6: 0 g ( ms) at 0.8 x I N, with curves F, F: 0 g ( ms) at 0.8 x I N to IEC , test Ea Corrosion 96 hours at % salt mist, to IEC , test Ka Humidity 40 hours at 9 % RH, to IEC , test Ca Mass approx g per pole depending on version UL 77 voltage number of poles I N max. (A) I cn (A) DC 80 V ,000 AC 77/480 V ,000 *under preparation Approvals VDE (EN 6094) UL 489 UL 77* 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

22 Magnetic and Hydraulic-Magnetic Circuit Breaker Ordering information Type No. 84 Mounting B flange mounting, with rectangular aperture with mounting nut 6-UNC C flange mounting, with rectangular aperture with mounting nut M E flange mounting, with round aperture with mounting nut 6-UNC F flange mounting, with round aperture with mounting nut M Configuration 0 without barrier with small barrier with large barrier (required for UL 489 multipole) Number of poles 0 single pole unprotected single pole protected two pole protected three pole protected 4 four pole protected P single pole protected, two poles connected in prallel Actuator configuration A all poles with standard toggle B reduced number of standard toggles Z without actuator Terminal design K screw terminals M4 A L screw terminals M 0 A M solder terminals 7 A P blade terminals A R round connectors 6 mm S stud terminals M 60 A T stud terminals -UNF-A 60 A U stud terminals M6 V stud terminals /4-0UNC-A A Terminal hardware 0 without with washer and nut 6 Phillips screws Characteristic curve K short delay DC K short delay AC M0 medium delay AC/DC M medium delay DC M medium delay AC Q0 switch only T long delay DC T long delay AC Illumination - without Version D standard Colour configuration B black front plate, black actuator, (black actuator base) B black front plate, white actuator, (black actuator base) B8 black front plate, blue actuator (black actuator base) Marking front plate actuator base A without without A I N without A I N without characteristic curve A4 I N, without characteristic curve, wiring diagram on side B without ON- B I N ON- B I N ON- characteristic curve B4 I N, ON- characteristic curve, wiring diagram on side Rated voltage B AC or 80 V DC 84 - C 0 A - U M -. D B A B -... Ordering information for auxiliary contact module Type number X84 Module S auxiliary contact module Auxiliary contacts 0 in all poles 0 in pole only 0 in poles + only 04 in pole only Auxiliary contact version H auxiliary contacts standard (asymmetrical terminals not for UL 489) K auxiliary contacts (symmetrical terminals) Auxiliary contact function W changeover W changeover Terminal design 0 microswitch with blade terminals DIN 4644-A,8-0, M mounted to base unit X84 - S 0 H W 0 M ordering example Current ratings 0... A 0-80 A single pole protected, two poles connected in parallel Approvals (optional) V UL C 0 A - U M -. D B A B - 60 A -. ordering example Remote trip coil available to special order! 84 - C 0 A - U M -. D B A B - 60 A Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

23 Magnetic and Hydraulic-Magnetic Circuit Breaker Dimensions Installation drawing Mounting version B/C Flange mounting rectangular aperture pole number of poles to 4 4 mounting thread M or 6- mounting depth 4. mm/.6 in. ON Cut-out dimensions: pole LOAD LINE multipole operating area (reinforced insulation) LOAD LINE.09 mounting area 9.4 terminal area ø Mounting version E/F Flange mounting round aperture number of poles to 4 pole 4 mounting thread M or 6- mounting depth 4. mm/.6 in. Actuator configuration A toggle per pole, mounting version B/C B reduced number of toggles per unit, mounting version B/C Cut-out dimensions: pole 4 pole 7. ±0. (M) (6-UNC).0.8 ±.004 (M) (6-UNC) ø Z without toggles ø LOAD LINE.079 ON A toggle per pole, mounting version E/F B reduced number of toggles per unit, mounting version E/F 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

24 Magnetic and Hydraulic-Magnetic Circuit Breaker Terminal design / Dimensions Number of poles / Dimensions P - with blade terminals LOAD LINE P pole protected, poles connected in parallel for rating currents from 0 to 80 A tightening torque: M8 max. 6 Nm 4.7 M8 LOAD LINE LINE K/L - with screw terminals blade terminal A (QC.0) DIN tightening torque: M6 max. Nm LOAD M - with solder terminals.8 LINE terminal with flat head screw M4 or M tightening torque max.. Nm Interphase barriers / Dimensions = = ø6.6 - Interphase barrier (small) - Interphase barrier (large) LOAD LINE LOAD LINE LOAD LINE S/U/T/V with auxiliary contacts (version H) asymmetrical terminals (not for UL 489) thickness mm /.09 in LOAD NC NO C LINE Internal connection diagram auxiliary contact module (change over) tightening torque: - UNF, M max. Nm /4-0 UNC, M6 max. Nm pole protected magnetically line multipole line R round connectors D = 6 mm (dia.6) (version H) asymmetrical terminals (not for UL 489) LOAD NC NO auxiliary contacts version K symmetrical terminals C LINE pole protected hydraulic-magnetically line 4 unit unit unit... unit LOAD LINE.87 NC NC NO NO C Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

25 Magnetic and Hydraulic-Magnetic Circuit Breaker Typical time/current characteristics at + C / +7.4 F (trip time at rated current and all poles symmetrically loaded) Curve K (short delay) for DC Curve M0 (medium delay) for AC/DC Curve K (short delay) for AC 0/60 Hz 000 Curve M (medium delay ) for DC Curve T (long delay) for DC Curve M (medium delay) for AC 0/60 Hz , 0, Curve T (long delay) for AC 0/60 Hz All curves will only be maintained if the escutcheon is mounted on a vertical surface. Other characteristic curves to special order ( e. g. pulse delayed, for high inrush currents or capacitive loads). 04/0 Phone: Germany (0 9 87) -0 - USA (847) UK (096)

26 Magnetic and Hydraulic-Magnetic Circuit Breaker Accessories Shock directions Splash cover (IP6) for,, pole (only for mounting version B) X pole X 444 pole X 444 pole 4 6 ON ON LINE LOAD ON Toggle guard (only for mounting version B/C) Y ø All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 0 Phone: Germany (0 9 87) -0 - USA (847) UK (096) /0

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

High Performance Thermal-Magnetic Circuit Breakers 410/520/

High Performance Thermal-Magnetic Circuit Breakers 410/520/ High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single

More information

High Performance Thermal Circuit Breaker

High Performance Thermal Circuit Breaker High Performance Thermal Circuit Breaker 43-... Description Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting.

More information

Thermal-Magnetic Circuit Breaker M1-..

Thermal-Magnetic Circuit Breaker M1-.. Thermal-Magnetic Circuit Breaker 30-...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection,

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 609) of compact design for snap-in panel mounting. Available

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 609) of compact design for snap-in panel mounting. Available either with protection on one/both/all

More information

Simulator switch, magnetic operation

Simulator switch, magnetic operation Description Single pole, miniaturised aircraft simulator switch with extremely fast magnetic trip time. Blade, screw and wire wrap terminals. Aircraft style threadneck and push/pull button with white trip

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Thermal Circuit Breaker / Switch Series 33 Description Combination of single pole circuit breaker and ON/OFF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination.

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data Thermal Circuit Breaker / Switch Series 33 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Thermal Circuit Breaker / Switch Series 33 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation CIRCUIT BREAKERS FOR EQUIPMENT TM Series Thermal magnetic release Positively trip-free Reset or manual actuation The TM circuit breaker for equipment (CBE) is a single pole, thermal-magnetically operated

More information

DD Frame - Series Circuit Breakers

DD Frame - Series Circuit Breakers The DD Frame is a compact yet very powerful circuit breaker. Using the hydraulic-magnetic technology which ensures that the breaker performance is unaffected by ambient temperature, the CI DD Frame series

More information

ER circuit breaker - Hydraulic magnetic,

ER circuit breaker - Hydraulic magnetic, ER circuit breaker - Hydraulic magnetic, Datasheet railway, high current and voltage Features Ideal for high current and high voltage applications Precise, temperature independent operation Panel mount

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

Circuit Breakers. DIN rail-mounted equipment protection

Circuit Breakers. DIN rail-mounted equipment protection Phoenix Contact offers a full family of modular components covering virtually all of your industrial electrical and electronic needs as well as a broad range of value-added services. CLIPLINE DIN rail-mount

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

AR circuit breaker - Hydraulic magnetic,

AR circuit breaker - Hydraulic magnetic, AR circuit breaker - Hydraulic magnetic, Datasheet railway, small Features Description Small hydraulic magnetic circuit breaker for railway applications to protect electronic equipment and components against

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Technical data. Miniature Circuit Breakers. System pro M. System pro M Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

FR circuit breaker - hydraulic magnetic,

FR circuit breaker - hydraulic magnetic, FR circuit breaker - hydraulic magnetic, Datasheet railway, very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON CIRCUIT BREAKERS FOR EQUIPMENT, POLE, PUSH BUTTON Product description The pole, push button actuated version of the line of thermal CBE s can be used for various purposes. Basically it is a CBE for automatic

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet FR circuit breaker - hydraulic magnetic, railway, Datasheet very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables JAE Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables 205 207 211 213 216 217 JAE/JRE/JLE Series Hydraulic Magnetic Circuit Protectors

More information

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826, S26 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826 Series Dual changeover switches with positive

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

CR circuit breaker - hydraulic magnetic,

CR circuit breaker - hydraulic magnetic, CR circuit breaker - hydraulic magnetic, Datasheet railway, compact Features Precise, temperature independent operation Panel mount Integrated auxiliary contacts (optional) Up to 6 poles configuration

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

55 Series - Miniature General Purpose Relays 5-10 A

55 Series - Miniature General Purpose Relays 5-10 A Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

PDR circuit breaker - Ground fault Datasheet

PDR circuit breaker - Ground fault Datasheet - Ground fault Datasheet protection device Features Blue housing 1-3 poles plus neutral 7-100mA Preciese, temperature independent operation Choise of time delays, terminals and actuator colours Application

More information

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59. Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

MS-Series. Circuit Breaker

MS-Series. Circuit Breaker MS-Series Circuit Breaker Carling Technologies MS-Series Sealed Toggle Circuit Breaker was designed and tested to operate flawlessly in the harshest of environments. Ideally suited for COTS (commercial

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature

More information

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Jtec 489 UL489 Branch Circuit Breaker

Jtec 489 UL489 Branch Circuit Breaker Jtec 489 UL489 Branch Circuit Breaker 10kA Miniature Circuit Breaker R The Jtec 489 range is UL 489 listed (File E255530). Available in trip curves Z (v. quick), B (quick), C (medium), K (motor) and D

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47. Snap-action switches Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.en Snap-action switches, S847 Series Dual changeover

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

209 Series. Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors 29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Catalog Issued 3-03 (PDF Rev )

Catalog Issued 3-03 (PDF Rev ) W6/W9 series Magnetic Hydraulic P& Circuit reakers Features Designed for the international market. UL Recognized (UL77 and UL5), CS ccepted and VDE approved. Ratings to 5 amps. Heavy duty #-32 stud connections.

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work GE Electrical Distribution Gerapid High Speed DC Circuit Breakers On the move imagination at work Gerapid High Speed DC Circuit Breakers To stay up and running today, you need equipment that delivers both

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information