MOISTURE LIQUID INDICATORS
|
|
- Katrina Townsend
- 6 years ago
- Views:
Transcription
1 MOISTURE LIQUI INITORS HENRY TEHNOLOGIES SIGHT GLSSES (ULLS EYE TYPE) lear Lens SG-1000 Series Reflex Lens SG-1100 Series P4453 These sight glasses are available in three basic styles; lear Lens; Reflex Lens; and lear Lens with Floating all. ll sight glasses feature a nickel plated steel body, hermetically sealed viewing lens, merican standard tapered pipe thread, 500 PSI maximum working pressure. These sight glasses are suitable for most standard refrigerants, and other industrial fluids non-corrosive to glass and steel (for R-11 applications, an aluminum ball is available for the SG-1200 s add suffix i.e. SG-1206). The SG-1000 s & SG-1100 s are rated for a maximum temperature of 500 F (260 ). The SG-1200's are rated for a maximum temperature of 300 F (148 ). The SG-1100 s (Reflex Lens) look dark when liquid is present and light when liquid is absent. P4453 lear Lens with Floating all SG Series PRT IMENSIONS (in.) THRE lear Reflex lear/ SIZE (in.) With all M.P.T. SG-1004 SG-1104 SG /2 SG-1006 SG-1106 SG /4 SG-1008 SG-1108 SG SG-1010 SG-1110 SG /4 SG-1012 SG-1112 SG /2 SG-1016 SG-1116 SG HENRY TEHNOLOGIES VERTIL SME SUTION LINE UMULTORS Inlet Outlet 1/4" FPT Relief onnection Inlet Outlet 1/4" FPT Relief onnection E* * HE Models Only HE: Heat Exchange models available by ordering with an HE suffix (ie. S-7721HE). Heat Exchange models feature a boil out coil to boil off liquid refrigerant in the bottom of the accumulator. The OS connection size of the boil out coil is shown in column E. *Optional: 1" FPT connection is available on S-7700 series for installation of a S type Liquid Level Switch. onsult factory. SPEIFITIONS P4454 S-7000 Series Maximum WP 400 PSI S-7000 Series Heat Exchange Model P in. FPT Model* PRT Std Heat Exchanger OS ONN. IMENSIONS IN INHES I. OS E S-7722 S-7721 S-7721HE 2-1/8 8-5/ /8 S-7726 S-7725 S-7725HE 2-5/8 10-3/ /8 S-7732 S-7731 S-7731HE 3-1/8 12-3/ /8 N S-7741 S-7741HE 4-1/ ontact Factory 2-5/8 N S / ontact Factory N/ PRT REFRIGERNT HOLING P. (lb 0 F sat) R-134a R-22 R-404a/ R-507 S S S S S MX MIN MX MIN MX MIN MX MIN MX MIN REFRIGERNT REOMMENE TONS REFRIGERTION T SUTION EVPORTING TEMPERTURE ( F) R-134a R-22 R-404/R F +20 F +0 F -20 F -40 F +40 F +20 F +0 F -20 F -40 F +40 F +20 F +0 F -20 F -40 F
2 UMULTORS N MUFFLERS HENRY TEHNOLOGIES HORIZONTL UMULTORS Liquid accumulators of this design should not be used when the temperature of the liquid refrigerant is less than +15 F in the accumulator. These accumulators have a 1/2-in. FPT connection for liquid injection and a 3/4-in. FPT connection for hot gas bypass. These connections can also be used for a relief device as required by UL 207. MXIMUM WP 302 PSI S-7600 SERIES P1147 PRT SIZE ONN. IMENSIONS (in.) ia REFRIGERNT HOLING P. (lbs 0 F ST.) REOMMENE TONS OF REFRIGERNT T SUTION EVPORTING TEMPERTURE ( F) R-134a R-22 R-404/R-507 R-134a R-22 R0404/R F +20 F +0 F +40 F +20 F +0 F +40 F +20 F +0 F S /8 OS S /8 OS S /8 OS HENRY TEHNOLOGIES ISHRGE LINE MUFFLERS PRT SIZE ONN. ia. S /2 OS 7.75 S /8 OS S /8 OS 9.69 S /8 OS 9.69 S /8 OS 6.75 S /8 OS 7 S /8 OS S /8 OS S /8 OS S /8 OS 21 S /8 OS 6 21 S /8 OS P1148 Selecting the Size of a Muffler Select a muffler with a connection size that matches or exceeds the line size of the compressor discharge line. There are no tonnage ratings for mufflers, since the muffler will remove pulsations from the discharge regardless of flow. S-6300 Series: Maximum working pressure 500 psig. S-6400 and S-6600 Series: Maximum working pressure 450 psig. 655
3 LIQUI REFRIGERNT REEIVERS HENRY TEHNOLOGIES LIQUI REFRIGERNT REEIVERS Receivers should be selected based on the operating charge for all system components, including the liquid lines. It is usual to add a small percentage to cover the refrigerant in long runs of suction and discharge lines, etc. It is essential that the maximum operating charge be determined, e.g., winter charge in air cooled condenser having flooded head pressure control, this being much greater than the normal summer charge. S-8060 SERIES VERTIL REEIVERS P1149 PRT *PUMP OWN PITY (lbs) R404/ R-134a R-22 R-507 IMENSIONS (in.) Maximum WP 450 PS *ll Pump own apacities are 90% of receiver 90 F. ia. ONNETIONS Inlet Outlet S S S /4 FLRE 1/4 FLRE 3 S S S /8 FLRE 3/8 FLRE 10 S /8 FLRE 1/2 FLRE S /2 FLRE 1/2 FLRE 21 S /8 FLRE 5/8 FLRE 26 WT. S-8600 SERIES HORIZONTL REEIVERS S-8600V SERIES HORIZONTL REEIVERS w/ RKETS & VLVES P1150 S-8600 SERIES HORIZONTL REEIVERS PRT MXIMUM WP 450 PSI *PUMP OWN PITY (lbs) IMENSIONS (in.) INLET SHIP R-404/ I. WEIGHT R-134a R-22 Inlet Outlet FPT R-507 (lb) /8 OS 5/8 OS 3/8 S S S /8 OS 5/8 OS 3/8 S S-8600V SERIES HORIZONTL REEIVERS WITH RKETS & VLVES PRT *PUMP OWN PITY (lbs) IMENSIONS (in.) ONNETIONS SHIP R-404/ I. WEIGHT R-134a R-22 E F G Inlet Outlet FPT R-507 (lb) S-8600V /2 OS 1/2 OS 3/8 19 S-8630V /2 OS 1/2 OS 3/8 28 *Pump own apacities are 90% of receiver 90 F. 656
4 LIQUI REFRIGERNT REEIVER ESSORIES HENRY TEHNOLOGIES REEIVER ESSORIES LIQUI LEVEL GUGES PRT REEIVER I. S /8 S /4 S /4 S S S S Mating flanges for level gauges not included on most receivers. P1165 RKET KITS PRT REEIVER I / / /4 NOTE: esigned for horizontal mounting use only. P1166 ROTO-LO VLVES PRT THRE OS / /4-12 7/ / / / / /8 Includes gasket. P1167 ROTO-LO/OS PTERS PRT THRE OS / /4-12 7/ / /8 Male stub designed for use on OS receiver connections when a Roto-Loc is desired. P
5 OIL SEPRTORS HENRY TEHNOLOGIES HELIL OIL SEPRTORS The helical oil separator features a centrifugal flow path achieving approximately 99% efficiency of oil separation with low pressure drop. P1151 S-5108/S-5181 S-5182 THRU S-5188 S-5190/S-5192 S-5290/S-5292 S-5202/S-5203/S-5204 PRT SIZE ONN. ia IMENSIONS (in.) MX. PITY IN TONS OF REFRIGERTION T EVPORTOR TEMPERTURE (nominal) R-134a R-22 R-404/R F +20 F +40 F +20 F +40 F +20 F MXIMUM ISHRGE FM S-5100 s - onnections are nickel plated steel. S-5200 s - onnections are copper plated steel. ll the capacities shown are based on 100 F condensing. Minimum tonnage is 33% of rated capacity, oversizing is not acceptable. PRE-HRGE MOUNT (oz) S /4 OS S /8 OS S /2 OS S /8 OS S /8 OS S /8 OS S /8 OS S /8 OS S /8 OS S /8 OS S /8 OS S /8 OS S /8 OS S /8 OS S /8 OS
6 OIL SEPRTORS HENRY TEHNOLOGIES ONVENTIONL OIL SEPRTORS P1152 PITY IN TONS OF REFRIGERTION T PRE- IMENSIONS MXIMUM PRT SIZE EVPORTOR TEMPERTURE (nominal) HRGE (in.) ISHRGE ONN. R-134a R-22 R-404/R-507 MOUNT FM ia 40 F +40 F 40 F +40 F 40 F +40 F (oz) S /2 OS S /8 OS S /8 OS S /8 OS S /8 OS onnections are nickel plated steel. Oil flow 175 PSI differential.80 gal/min. 3/8 flare oil return connection ll other capacities shown are based on 100 F condensing. Minimum tonnage is 33% of rated capacity, oversizing is not acceptable. S-5500 s ISHRGE FM HRTS FM HRT - R-22 FM HRT - R-404a/R/507 P1153 P1155 FM HRT - R-134a HOW TO LULTE ISHRGE FM (FM) Example: 50 ton R-22 system -25 F Evaporator Temp. 115 F ondensing Temp. From the R-22 FM hart, follow the -25 F evaporator temperature line to the intersection of the 115 F condensing temperature line. Extend a line horizontally from this point to the FM/ton factor. Multiply the FM/ton factor by the total tonnage to calculate the total FM. Example: P FM x 50 ton = 36.0 FM ton Oil Separator Selected: S
7 OIL SEPRTOR ESSORIES HENRY TEHNOLOGIES HET ELEMENTS J-Series Heat elements add heat to oil separators to prevent migration of refrigerant to the vessel during off cycles of the compressor. Heatelementscanalsobeusedonsuctionline accumulators to warm the oil and allow oil return to the compressor on low temperature applications. P4455 S-9101 P4455 PRT IMETER (in.) WTTGE VOLTS S-9112J 6 50W 240V S-9113J 4 25W 120V S-9114J 4 25W 240V S-9115J 2-1/2 25W 120V S W 110V S W 220V S W 220V P4456 P4456 OIL SEPRTORS The Replacement Float ssembly is used on the S-5200 & S-1900 series Oil Separators, and the is used on the S-5700 series Oil Separators. oth Replacement ssemblies include the gasket which can also be ordered separately (Part Number ). The S-5700 series screen cartridge can also be ordered as a replacement part (Part Number ). 3/8" OS oil return connection is available by ordering with an "X" suffix (i.e X). The Replacement Float ssembly is used on the S-5800 series Oil Separators. The Replacement ssembly includes the gasket (Part Number ). Part No. : Part No.: Part No.: P4457 P
8 OIL LEVEL REGULTORS (ONVENTIONL) HENRY TEHNOLOGIES OIL LEVEL REGULTORS The oil level regulator controls the oil level in the compressor crankcase with a float operated valve. Oil level regulators are designed to attach directly to the sight glass housing on compressor crankcases. dapter kits are available for compressors that have a different sight glass configuration. The sight glass from the compressor or supplied with an adapter kit, bolts to the second regulator flange for visual observation of the oil level. EQULIZTION ONN. 3/8" FLRE OIL LINE ONN. 3/8" FLRE 1/8 IN. S-9010 FIXE LEVEL REGULTOR The S-9010 regulator maintains the oil level in the compressor crankcase at 1/8-in. sight glass. The S-9010 maintains the level at any pressure differential* between 5 and 30 psi. The S-9010 oil level regulator is designed to bolt directly to the 3 bolt sight glass housing found on many compressor crankcases. o not use on Satellite ompressor. Part No.: S-9010 P1156 EQULIZTION ONN. 3/8" FLRE OIL LINE ONN. 3/8" FLRE JUSTMENT SREW S-9090 JUSTLE REGULTOR One oil level regulator for all applications The S-9090 regulator allows the oil level in the compressor crankcase to be maintained at any level between 1/4 and 1/2 sight glass. The S-9090 maintains the level at any pressure differential* between 5 and 90 psi. If the oil level in the crankcase is too high or too low, the level can be adjusted by turning the adjustment screw on top of the regulator. This can be done while the system is in operation. Our exclusive design eliminates the need of shutting down the system and disconnecting the oil feed lines in order to adjust the regulator. P1157 Part No.: S-9090 EQULIZTION ONN. 3/8" FLRE OIL LINE ONN. 3/8" FLRE JUSTMENT SREW P1158 *Operating Pressure ifferential The difference between the oil fed to the oil regulator and its compressor crankcase, where the regulator is controlling oil level. S-9130 JUSTLE REGULTOR The S-9130 regulator allows the oil level in the compressor crankcase to be maintained at any level between 1/4 and 1/2 sight glass. The S-9130 maintains the level at any pressure differential* between 5 and 90 psi. If the oil level in the crankcase is too high or too low, the level can be adjusted by turning the adjustment screw on top of the regulator. This can be done while the system is in operation. Our exclusive design eliminates the need of shutting down the system and disconnecting the oil feed lines in order to adjust the regulator. Part No.: S
9 OIL LEVEL REGULTORS (ONVENTIONL) HENRY TEHNOLOGIES ELETRO-MEHNIL OIL LEVEL REGULTORS S-9030 djustable Regulator The Electro-Mechanical Oil Level Regulator S-9030 provide a simplistic means for controlling oil level for hermetic, semi-hermetic, reciprocating and scroll compressors. through the use of a float switch and solenoid valve. magnetic reed float switch closes upon the reduction of oil level in the oil regulator body. This action energizes the solenoid valve thereby feeding oil into the regulator body. The oil level is adjustable by loosening the compression nut and manually adjusting the position of the float switch. low level alarm is also provided, for oil safety on hermetic and scroll compressors. If the oil level drops 1/8" below the set point, a second magnetic reed switch closes activating a customer supplied alarm. This alarm circuit may also be used to disconnect power from the compressor. While the regulator is in alarm the solenoid valve remains open trying to re-establish the oil level. Features: omplete oil level control without variations in pressure drop. 3/8" Flare normally closed solenoid valve. djustable between 1/4" and 1/2" glass. Low level alarm circuit. 24 Vac.25 amp. No UL considerations. Equalization connection 3/8" Flare. Operating differential 5 to 300 psig. Reliable float switch operation, 20 Va. pilot duty. ll major components replaceable. P4459 S-9030 djustable Regulator One oil level regulator for all applications The S-9030 Oil Level Regulator is designed to bolt directly to the three bolt sight glass housing found on many compressor crankcases. dapter kits are available for compressors that have a different sight glass configuration. The sight glass from the compressor or supplied with an adapter kit, bolts to the second regulator flange for visual observation of the oil level. LISTE " ia 3.18 P
10 OIL RESERVOIRS HENRY TEHNOLOGIES OIL RESERVOIR ue to system design, loads & defrost cycles, varying amounts of oil can be returned by the oil separator. ecause of this, a safety reserve of oil is required for the operation of our oil control system. The oil reservoir is the holding vessel for this stand-by oil. It has sight glass ports to observe the oil level inside the vessel. The valve on top of the Oil Reservoir receives oil from the Oil Separator, and the bottom valve distributes oil to the Oil Level Regulators. The valves are backseating and have a 1/4" flare connection, allowing the addition or removal of oil from the reservoir. High pressure gas returns with the oil from the Oil Separator to the Oil Reservoir. Pressure could build up in the Oil Reservoir to adversely affect the Oil Regulators. To prevent this, a vent line is installed from the top of the Oil Reservoir to the suction line. This line permits the pressure in the Oil Reservoir to be approximately the same as the suction line and the compressor crankcases. The 4 gallon model at. No. S-9108 should be used on very large systems, or systems with excessive oil charges, long line runs or any case where suction oil return may be impeded. New System Start-Up On system start-up of a new parallel system, oil should be added to the OIL RESERVOIR to the upper sight glass port, NOT OVE IT. It is commonly accepted that in a new refrigeration system, some oil will be absorbed by the refrigerant as the system becomes balanced out. fter two hours of operation, the OIL RESERVOIR, if necessary, should again be filled to the upper sight glass, and also after two days, by which time the entire refrigeration system should be balanced out. Then the OIL RESERVOIR must be observed on each service call. No oil should be added again until the oil level falls below the lower sight glass port. Existing System Start-Up When installing this OIL ONTROL SYSTEM, on a parallel system that has been in operation for some time, the amount of oil should be added cautiously. With the efficiency of the new OIL SEPRTOR, the oil return could likely be sufficient to fill the OIL RESERVOIR to the lower sight glass port only. Observe for one day. fter the second day, if the oil level has not risen to the upper sight glass, add oil. If the oil level has risen above the upper sight glass port, remove the excess oil from the OIL RESERVOIR. S-9109 S " ia P4468 P4468 P4467 P4467 LISTE OF IMENSIONS PRT PITY (IN GLLONS) SIGHT (in.) GLSSES S /2 3/ S /4 3/
11 OIL LEVEL ONTROL ESSORIES HENRY TEHNOLOGIES ELETRONI OIL LEVEL ONTROL N ESSORIES The Electronic Oil Level ontrol System is a new type of oil level control technology for use on multiple compressor refrigeration systems. The system consists of on Oil Level ontroller which allows a preset oil level to be maintained in each compressor. It uses an optical Oil Level Transducer (1 per compressor) to sense oil level in each compressor crankcase. Part Number S-9310 djustable ontroller can maintain between a 1/4 and a 1/2 oil level in a compressor crankcase and the operating differential of 5-90 psig. The additional necessary hardware for the S-9310 includes the S-9310M or solenoid valves, and the S-9330 Transducer. The S-9310 is factory wired for 230 V but can be changed in the field to 115 V. Part Number S-9330 Transducer is used with the S-9310 adjustable Electronic Oil Level ontroller. The S-9330 transducer optically senses the oil level through the sight glass & transmits a signal to the controller. P4461 NOTE: The S-4004 or S-4005 Oil Filters must be used to capture any foreign material that will ultimately cause the Electronic Oil Level ontrol System problems. Not using the same type of oil filters will void the warranty. S-9330 P OLT 1 7/8".. P4462 Part Number S-9310M Solenoid Manifold is used with the S-9310 Electronic Oil Level ontroller. S-9310M feeds oil to the crankcase when the controller calls for oil. The S-9310M is designed to be mounted externally of the wiring panel. Part Number Solenoid Valve is used with the S-9310 Electronic Oil Level ontroller. The solenoid valve is piped directly in the oil return line to the compressor. 3/8" Flare From Oil Resevoir 3.25" P4463 Part Number Sight Glass dapter Kit is for compressors with only one crank-case sight glass. The 3-olt flange Oil Level Transducer (S-9330) does not allow for a visual observation of the oil level in compressors. This adapter kit provides an additional sight glass and a 1/4" flare equalization/oil fill connection. Vent Oil Reservoir Oil Filter Sight Glass S-9330 Transducer 3/8" Flare Reservoir Pressure Valve Solenoids & Manifold P4465 S-9310 ontroller Oil Separator Satellite ompressor Parallel ompressors 3 olt 1 7/8".. P4464 P
12 OIL LEVEL REGULTORS N ONTROL ESSORIES HENRY TEHNOLOGIES OIL LEVEL REGULTOR PTER KIT SIGHT GLSS OIL LEVEL OMPRESSOR MNUFTURER SIGHT GLSS ONFIGURTION PTER KIT PRT 1/2 unham-ush ig 4 3 olt 1-7/ * 1/2 Trane 3 olt 1-7/ * 1/2 York 3 olt 1-7/ * 1/4 arrier (models E & ER) 3 olt 1-7/ * 1/4 opeland (over 5 tons) 3 olt 1-7/ * 1/2 opeland (under 5 tons) 1-1/8-12 Thread /2 Prestcold (model K ) 1-1/8-12 Thread /2 unham-ush (model ) 4 olt 2-1/ /4 arrier (,R,5F,5H & 06) 1-1/2-18 Thread /2 Schnacke-Grasso 2 x 16 Thread /2 Trane 5 olt 2-1/ SIGHT GLSS OIL LEVEL OMPRESSOR MNUFTURER SIGHT GLSS ONFIGURTION PTER KIT PRT 1/4 opeland (older model) 4 olt 2-1/ /2 Vilter 1-1/2 NPT Thread /2 Vilter 2 NPT Thread /4 opeland (model 8R ) 3 olt 1-7/ /2 Prestcold (,E,R,L, & LG) 42mm Thread /2 Trane (model K ) 3/4 NPT Thread /2 Schancke-Grasso 1-1/4 NPT Thread /2 Grasso Thermtrol 1 NPT Thread /2 ristol 15/16-20 Thread /2 ock 4 olt 1-31/ /2 Maneurop 1-1/8-18 thread /2 itzer 4 olt ll kits include necessary hardware, gaskets and sight glasses to mount Oil Level Regulators to various compressors shown in this table. *KIT INLUE WITH LL OIL LEVEL REGULTORS NOTE: For compressors not listed above, a universal adapter kit is available Part No This adapter kit has a 3-hole flange to mount to the regulator. The compressor end of the kit is a 1-1/4" O steel tube. The existing compressor sight glass gland or flange must be bored out or bushed down to accept the 1-1/4" tube. The tube is then brazed or welded to the reworked gland or flange and installed on the compressor. P4474 HENRY TEHNOLOGIES OIL LEVEL ONTROL OMPONENTS PRESSURE VLVE PRT PRESSURE SETTING S lbs S-9104H Used with oil reservoir. 20 lbs SHUT-OFF RSS VLVES SIZE ONNETION 3/8 Female x 3/8 Male Flare 3/8 Female x 3/8 Male Flare 2.47" PRT TYPE S-9106H 3/8 Flare 3/8 Fem. Flare Vertical S-9106V 3/8 Flare 3/8 Fem. Flare Horizontal Vertical Type INLET Horizontal Type INLET P1159 EQULIZTION PTER KIT PRT " 1/4" FLRE SIGHT GLSS INSTLLTION TOOL Used on all 06, 06, and 06E models. Part No.: T OLT 1 7/8".. P1162 P4405 (SWIVEL ONNETION) OIL LINE STRINER (SWIVEL ONNETION) P RREL NUT SOKET Special socket to remove and torque 06 terminal nuts. Used on all 06 models. Part No.: P PRT ONNETION SREEN SIZE. T S /8 Flare 100 Mesh x 11 sq. in. Used to protect oil regulators by removing foreign matter. 5" 3/8 OS connections available by ordering with an X suffix (i.e., S-9105X) P
13 REFRIGERTION OIL FILTER RIERS HENRY TEHNOLOGIES OIL FILTER POE OIL FILTER-RIER Part Number S-4004 Our S-4004 Oil Filter removes foreign material from the oil as it passes through the filter. The filter easily captures any debris that may be in the system, such as dirt, metal chips, etc. (particle retention 10 micron). The S-4004 is required on all Electronic Oil Level ontrollers to protect the solenoid manifold. P4469 Part Number S-4005 POE Oil Filter & rier for POE oil return on systems using Oil Separators and Oil ontrol Systems. This is not a refrigerant Filter rier. It is designed to operate at a very low pressure drop in a 100% oil environment. P4470 Part Number S-4005 POE Oil Filter & rier was designed to clean and dry POE oil as it is returned to the compressor crankcase or Oil Reservoir in parallel systems.lean and dry POE oil assures the proper operation of the float assemblies in the Oil Separator and the Oil Level Regulators. P4471 S-4004 & S /8" Flare 3/8" Flare New POE Oil Filter & rier 4" 7 3/8" P4472 P
14 HEK VLVES HENRY TEHNOLOGIES HEK VLVES (Globe esign) FORGE RSS OY TYPE 116 TEMPERTURE RTING 40 F TO +300 F MXIMUM WORKING PRESSURE 500 PSI P440 FORGE RSS OY ( ) Teflon synthetic seat, with fully guided piston and stainless steel spring. Will operate in any position except bonnet down. Internal parts can be easily removed to prevent damage when soldering valve into line. Suitable for highside or lowside installation and hot gas applications, refrigerants and other industrial fluids, non-corrosive to brass and steel. INLET P4478 PRT SIZE ONN. IMENSIONS IN INHES WT (Lb) /8 OS /2 OS /8 OS /8 OS TYPE 205 MXIMUM WORKING PRESSURE 500 PSI TEMPERTURE RTING 20 F TO +300 F Type 205 INLET P443 P4477 PRT SIZE ONN. IMENSIONS IN INHES WT (Lb) 205-7/8 7/ /8 1-1/ /8 1-3/ /8 1-5/ /8 2-1/ /8 2-5/
15 HEK VLVES HENRY TEHNOLOGIES HEK VLVES (Straight Through esign) RSS OY TYPE 119 rass onstruction with Synthetic Rubber Seat omplete Piston Guidance Stainless Steel Spring Operates in ny Position Temperature Rating 20 F to +200 F Maximum Working Pressure 500 PSI ompact, sturdy and noiseless in operation, with minimum pressure drop. Type 119 S..E. Male Flare P4475 PRT SIZE ONN. IMENSIONS IN INHES WT (Lb) 119-1/4 1/4 FL /8 3/8 FL RSS OY TYPE 120 P442 SOLER ONNETIONS EXTENE OPPER ENS 120 ( ) Type 120 Solder rass onstruction with Synthetic Rubber Seat omplete Piston Guidance Stainless Steel Spring Operates in ny Position Temperature Rating 20 F to 200 F Maximum Working Pressure 500 PSI ompact, sturdy and noiseless in operation, with minimum pressure drop. P4476 PRT SIZE ONN. IMENSIONS IN INHES WT (Lb) 120-3/8 3/8 OS /2 1/2 OS /8 5/8 OS /8 7/8 OS HENRY TEHNOLOGIES NGLE HEK VLVES P445 SIZE IMENSIONS (in.) PRT ONNETONS enter to enter to Overall (in.) ottom Side Height 215-7/8 7/8 OS 1-1/2 1-3/4 3-3/ /8 1-1/8 OS 1-3/4 2-3/16 3-7/ /8 1-3/8 OS 1-15/16 2-7/16 4-3/ /8 1-5/8 OS 2-5/32 2-3/4 5-1/16 668
16 PKLESS VLVES HENRY TEHNOLOGIES PKLESS VLVES Standard Type Forged rass ored ody and onnet Recommended for Vacuum pplications and Service Pressures up to 500 PSI Non-irectional Flow ackseating Lower Stem iaphragms are hangeable Under Line Pressure Temperature Rating 20 F to +275 F Standard Globe Valves O.. Solder P4479 PRT SIZE ONN. IMENSIONS IN INHES WT (in.) Mtg Hole trs (lb) 6261N 1/4 OS N 3/8 OS N 1/2 OS N 5/8 OS N 3/4 OS N 7/8 OS N 1-1/8 OS Standard ngle Valves O.. Solder P4480 PRT SIZE ONN. IMENSIONS IN INHES WT (in.) (lb) 6471N 1/4 OS N 3/8 OS N 1/2 OS N 5/8 OS N 3/4 OS N 7/8 OS N 1-1/8 OS Hand Expansion Valves Standard Type P4481 PRT SIZE ONN. IMENSIONS IN INHES WT (in.) Ori. ia. Mtg Hole trs (lb) 6291N 1/4 OS N 3/8 OS N 1/2 OS N 5/8 OS N 3/4 OS N 7/8 OS N 1-1/8 OS harging and Purging Valves Globe Standard Type P4482 PRT SIZE ONN. IMENSIONS IN INHES WT (in.) Mtg Hole trs (lb) 6231N 1/2 OS x 1/4 Flare N 3/8 OS x 3/8 Flare N 1/2 OS x 1/2 Flare N 5/8 OS x 5/8 Flare harging and Purging Valves Single Standard Type PRT SIZE ONN. (in.) IMENSIONS IN INHES WT ottom Side (lb) 6432N 3/8 OS 3/8 Flare P
17 REEIVER VLVES HENRY TEHNOLOGIES REEIVER VLVES Packed, ngle Type NGLE VLVE NON-K-SETING TYPE 776-1/4 Fare onnection P4484 NGLE VLVE K-SETING TYPE 779-, TYPE 783 E E P4485 Temperature Rating: 20 F to +300 F 500 PSI Maximum Working Pressure Forged rass ody PRT SIZE ONN. (in.) IMENSIONS IN INHES ottom Side E WT (Lb) Forged rass Non-ack-Seating /4 MPT 1/4 FL /4 OS /4 MPT 1/4 FPT /16 OS /4 MPT 3/8 FL /16 OS /8 MPT 1/4 FL /8 OS /8 MPT 3/8 FL /8 OS /8 MPT 1/2 FL /8 OS /2 MPT 3/8 FL /2 OS /2 MPT 5/8 FL /2 OS.91 Forged rass ack-seating /2 MPT 1/2 FL / /2 MPT 5/8 FL /2.69 Forged rass ack-seating* /8 OS /2 OS /8 OS /8 OS /8 OS /8 OS /8 OS *Furnished with 1/4-in. flare capped charging and testing connection above back-seat. HENRY TEHNOLOGIES PKE NGLE TYPE, HRGING N PURGING Forged rass ody, Plated lack Oxided Steel Stem and Molded Valox Seal ap, rass Flare aps. Temperature Rating: 20 F ( 29 ) to +300 F (+149 ). Maximum Working Pressure: 500 PSI, (35 Kg/cm 2 ) Valves Furnished isassembled to void Excessive Heating of Internal Parts uring razing. P4486 TYPE 927 NON-KSETING PRT SIZE ONNETIONS (in.) IMENSIONS (in.) ottom Side WT (Lb) /4 OS 1/4 Flare /8 OS 1/4 Flare /8 OS 3/8 Flare /2 OS 1/4 Flare /2 OS 3/8 Flare
18 SEL P VLVES HENRY TEHNOLOGIES SEL P VLVES ackseating esign Forged rass ody with Integral Mounting Flange, Plated Steel Stem; rass onnet and Molded Valox Seal ap. ackseating: an e Repacked Under Pressure. Temperature Rating: 20 F ( 29 ) to +300 F (+149 ) Maximum Working Pressure: 500 PSI, (35 Kg/cm 2 ) Recommended for Hot Gas Service or Other High Temperature pplications. PRT SIZE ONNETIONS (in.) IMENSIONS (in.) E F WT (Lb) /4 OS /8 OS /2 OS /8 OS TYPE 926 Mounting Flange 2 Holes E olt enters P4487 HENRY TEHNOLOGIES SEL P VLVES GLOE ESIGN Valve odies: ast ronze. ackseating: an e Repacked Under Pressure. Temperature Rating: 40 F ( 40 ) to +325 F (+163 ) Maximum Working Pressure: 450 PSI, (31 Kg/cm 2 ). TYPE 203 P4488 PRT SIZE ONNETIONS (in.) IMENSIONS (in.) WT (Lb) /8 OS /8 OS /8 OS /8 OS /8 OS /8 OS /8 OS
19 VLVES HENRY TEHNOLOGIES THREE-WY UL SHUT-OFF VLVES INLET P297-2 odies: 92 Series: Forged rass; 802 Series: Forged Steel; Painted. Maximum Working Pressure: 450 PSIG (31.5 Kg/m 2 ) Temperature Rating: 20 F ( 29 ) to +300 F (+149 ) Recommended for Use with Relief Valve Types. 802 Series is Suitable for Refrigerants Including mmonia and Other Industrial Fluids Non-orrosive to Steel. INLET E P4489 PRT SIZE ONNETIONS (in.) IMENSIONS (in.) E WT (Lb) 923 3/8 NPTF /2 NPTF /4 NPTF /2 NPTF /4 NPTF NPTF /4 NPTF
20 PRESSURE RELIEF VLVES HENRY TEHNOLOGIES PRESSURE RELIEF VLVES tmospheric, ngle & Straight-Thru Types rass onstruction Set and Sealed at the Factory; ll NPTF onnections are merican Standard ryseal Tapered Pipe Threads Valves are Stamped with atalog Number, Size, Pressure Setting, apacity and SME-UV National oard Symbol; RN Number and Flow rrow ll NPTF onnections are merican Standard ryseal Tapered Pipe Threads Positive Pressure Relief Suitable for Refrigerants 12, 22, 500, 502, 12, 134a, and Other Industrial Fluids Non-orrosive to rass, Monel, Steel and Teflon Temperature Rating: 40 F ( 40 ) to +225 F (+107 ) Orders Must Specify atalog Number, Pressure Setting, and Type of Refrigerant or Fluid With Which the Valve is to be Used; UV/N ertified Setting Range PSI. ontact Henry for Non-ertified Setting Range Information. Standard Settings re: 235 PSI, 300 PSI, 350 PSI, 400 PSI, 425 PSI, 450 PSI IMPORTNT: ORERS MUST SPEIFY PRESSURE SETTING. RNGE 150 to 450 PSI TMOSPHERI RELIEF VLVES PRT SIZE ONN. INLET IM/IN. ORIFIE I. WT (lb) /4 MPT /8 MPT NGLE RELIEF VLVES PRT SIZE ONN. IM./IN. ORIFIE WT Inlet Outlet I. (lb) 526E 3/8 MPT 3/8 FL E 1/2 MPT 5/8 FL STRIGHT-THRU RELIEF VLVES INLET Type 522 tmospheric P4490 PRT SIZE ONN. IM./IN. ORIFIE WT Inlet Outlet I. (lb) /4 MPT 3/8 FL /8 MPT 3/8 FL /8 MPT 1/2 FL /2 MPT 5/8 FL /2 1/2 MPT 3/4 FPT /4 3/4 MPT 3/4 FPT MPT 1 FPT RELIEF VLVE PITY RTINGS PRT STNR PRESSURE SETTING (psig) E E / / INLET Type 52 ngle INLET Type 523 & 524 Straight Thru P4492 P4491 SME N National oard ertified 673
21 RUPTURE IS SSEMLIES HENRY TEHNOLOGIES RUPTURE IS SSEMLIES 5525 & 5526 rass Series; 5626, 5627, 5628 and 5629 Stainless Steel Series Tested and ertified to SME Section VIII iv I Prevents Leakage or Weeping of Fs Through the Relief Valve Extra Gauge Port for Installation of a Pressure Switch to Warn of a Refrigerant Release aused by a System Malfunction Non-Fragmenting Rupture isc Rupture isc ssembly Factory Sealed 1/8" NPT 1/8" NPT INLET P4496 PRT Inlet MPT SIZE ONN. Outlet FPT RUPTURE IS SETTING 72 F PSI WT (lb) /8 3/ /8 3/ /8 3/ /8 3/ /2 1/ /2 1/ /2 1/ /2 1/ /2 1/ /2 1/ /2 1/ /4 3/ /4 3/ /4 3/ /4 3/ /4 3/ /4 1-1/ /4 1-1/ /4 1-1/
22 USE NO OIL MXINPUT 600 psi USE NO OIL MXINPUT 600 psi RUPTURE SSEMLY PRESSURE SWITHES/INITORS HENRY TEHNOLOGIES RUPTURE SSEMLY PRESSURE SWITH Type: irect ction lade ontact ontacts: Silver lloy, Gold Plated Set Point: Factory Set and Sealed Pressure Setting: 5 PSI Switch urst Pressure: 750 PSI Ratings: 4 MP - 24 V iaphragm: TEFLON Temperature Range: 40 F to +250 F onnector: 1/8-27 NPT Male Thread Terminals: METRI-PK, 1/4-in. lade ircuitry: Normally Opened ase: Steel over: Glass Reinforced Polyester Furnished with METRI-PK onnector and 10 ft of Wire NOTES: The addition of a Sentry Pressure Switch provides an inexpensive means of providing an electrical signal to warn of a refrigerant release caused by a system malfunction. n extra gauge port is provided on the Sentry Rupture isc ssembly for the switch Pressure Switch Part No.: SW56 P4497 P4497 HENRY TEHNOLOGIES RUPTURE SSEMLY PRESSURE INITOR ial: 1-3/8-in. (35 mm), White luminum ial with Red Marking ial: Maximum Working Pressure: 600 PSI ase: ISI 304 Stainless Steel Lens: Plexiglass, Watertight Pointer: ISI 304 Stainless Steel Socket: ISI 304 Stainless Steel mbient Temperature: 40 F/+150 F ( ) NOTES: The Pressure Indicator (Item ) can be used with our Sentry Rupture isc ssembly (Item ), which helps prevent leakage of both halocarbon and ammonia refrigerants by indicating whether the relief valve had discharged. The Sentry Rupture isc ssembly, as required by NSI/SME ode, provides a chamber between the rupture disc and the relief valve, and a connection to install the new pressure indicator. This arrangement permits a positive indication that the disc has ruptured and the relief valve has discharged. Item Pressure Indicator G15 USE NO OIL MXINPUT 600 psi P4498 P4499 Item The Sentry Rupture isc ssembly/relief Valve ombination is showninitsnormaloperatingconditionwithsystempressureonly under the Rupture isc. (See first pressure gauge.) USE NO OIL MX INPUT 500 psi NOTE: Relief valve, pressure gauge and pipe plug not included with Sentry Rupture isc ssembly. P4498 PRT G15 SIZE ONNETION 1/8-in. MPT, ack P
23 RUPTURE SSEMLY PRESSURE SWITHES/INITORS HENRY TEHNOLOGIES TRNSUER VLVE Forged rass Temperature Rating: 20 F ( 29 ) to +300 F (+149 ) Maximum Working Pressure: 500 PSI (35 kg/cm 2 ) onnector: 1/4-in. Flare ccess with Schrader ore Provides ccess to Systems and Mounting of a Transducer to Monitor Systems Performance Provides Schrader Valve Port for hecking Transducer Output with a Pressure Gauge Provides Isolation from System for Replacement of Transducer Suitable for Refrigerants and Other Industrial Fluids Non-orrosive to rass and Steel P4501 PRT SIZE ONN. IMENSIONS IN INHES WT (lb) Side ottom /8 FPT-1/4 FL 1/4 MPT
April 2007 / BULLETIN Solenoid Valves. The right solenoid valve for any job.
pril 2007 / BULLETIN 30-10 Solenoid Valves The right solenoid valve for any job. Bulletin 30-10 / Page 1 Sporlan Solenoid Valves Benefits Molded coil for most sizes. lass "F" temperature rating oil types
More informationSuperior Supplying Quality Products To The ACR Industry Since 1938
Catalog No. R-200 Superior Supplying Quality Products To The CR Industry Since 98 ir Conditioning and Refrigeration Valves, Wrot and Flare Fittings, and ccessories Catalog No. R-200 ir Conditioning and
More informationOIL LEVEL CONTROL BOOKLET
CHATHAM, IL U.S.A. 62629 OIL LEVEL CONTROL BOOKLET INSTALLATION AND SERVICE INSTRUCTIONS SECTION TITLE PAGES I INTRODUCTION 1 II TYPES OF SYSTEMS 2 III OIL SEPARATORS 3 IV OIL RESERVOIRS 4 V MECHANICAL
More informationCHECK VALVES MUELLER CHECK VALVES TECHNICAL DATA. Flare to Flare. Solder to Solder. Solder to Solder - Extended Ends. Shipped loosely assembled.
MUELLER CHECK VLVES TECHNICL DT CHECK VLVES vailable in 1/4 through 5/8 flare sizes and 1/4 thru 7/8 solder sizes. Recognized under the component program of Underwriters Laboratories for use in the US
More informationOil Management. Temprite Oil Reservoirs. Model Maximum Working Pressure: 44.8 bar (650 PSI) RES7 Oil Reservoir for CO 2
Temprite Oil Reservoirs Model 47154 Maximum Working Pressure: 44.8 bar (650 PSI) 47154 Part # Model # Oil onn. apacity apacity E Sight Glasses 90040000 47154 3/8" SE 4 Gal. 512 oz. 15 Liters 3.5 Gal. 448
More informationProduct Catalog. ...the Leader in Refrigeration Innovation
Product atalog...the Leader in Refrigeration Innovation www.temprite.com email: temprite@temprite.com 1555 West Hawthorne Lane, Suite 1E West hicago, Illinois 60185-1822 US 1.800.552.9300 Phone: 630.293.5910
More informationCHECK VALVES. Flare to Flare. Solder to Solder. Solder to Solder - Extended Ends. Shipped loosely assembled.
CHECK VLVES MUELLER CHECK VLVES DESIGN FETURES 1. Soft neoprene seat provides positive seal against reverse flow. 2. Four space tabs maintain washer/seat alignment and guide the seat disc for smooth operation.
More informationAC&R Product Catalogue
C&R Product Catalogue Table of Contents Policy Statement...3.0 Helical Oil Separators...4.0 Helical Oil Separator Reservoirs... 5.0 Helical Oil Separator Capacity Data... 6.0 Oil Separator Selection...6.0
More informationModulating Water Valves and Bulb Wells
Modulating Water Valves and ulb Wells PPLITION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature
More informationC U S T O M E R D R I V E N R E S U L T S O R I E N T E D
C O M P O N E N T S F O R T H E R E F R I G E R A T I O N A N D A I R C O N D I T I O N I N G I N D U S T R Y C U S T O M E R D R I V E N R E S U L T S O R I E N T E D C A T A L O G 1 0 9 E D I T I O N
More informationHANTEMP Controls. COBRA-NECK Stainless Steel Ball Valves. HANTEMP Controls SSBV COBRA-NECK BALL VALVE FOR INDUSTRIAL REFRIGERATION 3/4 TO 3
HNTEMP ontrols ulletin V 1622f OR-NEK Stainless Steel all Valves U.S. Patent - 9,518,665 Made in US SSV OR-NEK LL VLVE FOR INUSTRIL REFRIGERTION 3/4 TO 3 1 SSV with Electric ctuator ESRIPTION HNTEMP ontrols
More informationWEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS
SUPERIOR - BALL VALVES WA SERIES (WELDED) WAS Series (Welded with Access Fittings) Full Service Temperature Range of -40 F to +325 F. Forged Brass Body and Seal Cap. Design Working Pressure: 700 psig.
More informationAN ISO 9001 : 2008 COMPANY GLOBE VALVES. Get the edge in process control. Butterfly Valves India Pvt. Ltd.
N ISO 9001 : 2008 OMPNY GLOE VLVES Get the edge in process control utterfly Valves India Pvt. Ltd. Introduction Hi-TEH Manufacturing Programme Valve Type End SME 2 2½ 3 4 5 6 8 10 12 onn. lass DESIGN STNDRD
More informationModel ZW204 Non-Modulating Float Valve
Model Z04 Non-Modulating loat Valve pplication The Zurn ilkins Model Z04 Non-Modulating loat Operated ontrol Valve is designed to be either fully open or fully closed in response to the position of the
More informationW94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection
Temperature Model W91 (No Indicating Dial) W94 (Temperature Indicating Dial) Service Water, Steam, Other Liquids Sizes 1/2 4 onnections Threaded, Union Ends, 125# FLG 250# FLG (optional) ody Material 1/2
More informationFRL/AirCare Air Controls & Accessories
FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor
More information197C. Valve Group. Series Farris Engineering Pressure Relief Valves
97 Valve Group Series 700 Farris Engineering Pressure Relief Valves Numbering System Selecting and specifying Farris pressure relief valves is simple using the numbering system that follows. Each digit
More informationResilient-Seated Gate Valves with Vertical or Cross Wall Post Indicator
Worldwide ontacts www.tyco-fire.com Resilient-Seated Gate Valves with Vertical or ross Wall Post Indicator General Description TYO Resilient-Seated Gate Valves with Vertical and ross Wall Indicators are
More informationResilient-Seated Gate Valves with Vertical or Cross Wall Post Indicator
Worldwide ontacts www.tyco-fire.com Resilient-Seated Gate Valves with Vertical or ross Wall Post Indicator General Description TYO Resilient-Seated Gate Valves with Vertical and ross Wall Indicators are
More informationPiston Accumulators Series Catalog HY /US Page
Page Series 5000 Series 5000 Piston ccumulators Heavy uty Service with 5000 PSI Operating Pressure 2" thru 9" ores with Over 30 Standard apacities Patented V-O-ring Piston Seals Serviceable Threaded End
More informationSpecifications, Applications, Service Instructions & Parts. HCK1, HCK1W PISTON-TYPE CHECK VALVE ¾" thru 6" (20 thru 150 mm)
Bulletin Specifications, Applications, Service Instructions & Parts HCK1, HCK1W PISTON-TYPE CHECK VALVE ¾" thru (20 thru 150 mm) d ¾" thru FPT, SW, WN, ODS for refrigerants Piston-Type Check Valve: HCK1
More informationF20 & F21 QIX Particulate & Coalescing Filters
F2, F21 Series QIX Filters 1/4, 3/8, 1/2, 3/4 & 1 Inch Ports F2 & F21 QIX Particulate & oalescing Filters Manual rain utomatic rain Unique Interchangeable QIX Inserts llow One Module to ccommodate Port
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationSELECTION. Easily Selectable Easily Serviceable. Interchangeability as easy as 1-2-3
SELETION Terminal Unit Zone Valve 1 Select your valve body Female Thread Solder ouble Union 2 Select your cartridge type hoice of V Hot and hilled Water 50% Glycol Low Pressure Steam Pressure alanced Male
More informationThe System Features These Advantages: Designing the Low Pressure Oil Return System
JANUARY 2004 / Bulletin 110-10 Sporlan s Oil Level Control System components were developed to offer the refrigeration industry an oil level control system of the highest quality. The heart of the system
More informationMagHex Fan Controller
MagHex Fan ontroller 0916 ompact Programmable Temperature Sensor This combined sensor and controller is designed to mount directly to the heat exchanger. It provides accurate temperature control by cycling
More informationBC SERIES CHECK VALVE
SERIES HEK VLVE Soft ubble Tight 1/2 psi racking Pressure NR Standard (Viton Optional, use Suffix V) Lead Free option, use suffix LF omplies with alifornia 1953 Max Working Pressure 1/4 thru 400 psi WOG
More informationFlow Controls & Accessories
Flow ontrols & ccessories Section Flow ontrol Valves SPF Series...2 337 Series...3 3250 Series... 4-5 Right ngle Series... 6-9 Needle Valves SPN Series...10 338 Series...11 SP Series heck Valve...12 339
More informationModel Model 815
Model 600004 Model 600204 Model 85387 Model 600104 Model 815 ir line products and accessories ir couplers and nipples............................... 196 low guns, tire inflators and siphon sprayers.............
More informationElectronic Temperature Control & Bulb Well Assembly (AC)
Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed
More informationPiston Accumulators Series Catalog /USA Page
atalog 1630-7/US Page Piston ccumulators Series 5000 Series 5000 Piston ccumulators Heavy uty Service with 5000 PSI Operating Pressure 2" thru 9" ores with Over 30 Standard apacities Patented V-O-ring
More informationISO 9002 Hansen Technologies Corp. Burr Ridge, IL Cert. # Orlando, FL Cert. #
HANSEN CORPORATION TECHNOLOGIES Specifications, Applications, Service Instructions & Parts HCK, HCKW PISTON-TYPE CHECK VALVE ¾" thru 6" (0 thru 50 mm) Flanged ¾" thru " FPT, SW, WN, ODS for refrigerants
More informationACCESSORIES 204 ACCESSORIES
ESSORIES E S S O R I E S rystal Fountains manufactures a select line of water feature accessories. From swivel units to help align spray nozzles to hydraulic fill valves, rystal Fountains manufactures
More informationYour Global Source for Today s Most Popular Solenoid Valves
lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International
More informationCONTROL VALVES W910 Series
ONTROL ompact ontrol Valve Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel ompany Models W910, W910, W910, W910T, W910EP,
More informationCipriani Harrison Valves Corp.
pplication Sanitary ball valves are used in stainless steel piping systems for isolation, either manually or automatically operated. The full port design with zero flow restriction makes it an optimum
More informationVB-7000 Series 1/2 to 2 Globe Valves
V-7000 Series 1/2 to 2 Globe Valves with MG350V Series SmartX ctuators schneider-electric.com 1 Product Description Schneider Electric MG350V non-spring actuators and V-7000 series two and three-way globe
More informationPin & Sleeve. Heavy Duty Industrial Wiring Devices for North American and European Markets
Pin & Sleeve Heavy Duty Industrial Wiring Devices for North merican and European Markets Pin & Sleeve SFETY, PERFORMNE ND DURILITY...IN SNP! Extensive Product Family: - Safe and reliable, portable electrical
More information3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators
lectric, Hydraulic, and Pneumatic ctuators TL 1. Select Valve ody including P ode (Valve Size, v Rating, Port ode) or select Valve ssemly correct (refer to Tale 3 and Tale 3 also) less ctuator ode (XXX)
More informationYSB SERIES Y - STRAINER
YS SERIES Y - STRINER ronze Y Strainer to 4 100% merican Made Self-ligning Screen Design vailable NPT or Solder onnection Working Pressure (cold non-shock) 125 psi @ 350 F Steam 400 psi @ 150 F WOG RN
More informationMIS SERIES. Mist Eliminator. Installed differential pressure gauge and optional zero air-loss drain valve. Air or Water Cooled Aftercooler
MIS SERIES Mist Eliminator The ircel MIS Mist Eliminator (300-8000 scfm) provides a full line of mist eliminators to effectively remove oil, solids and water from your compressed air system. In addition,
More informationHand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )
Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 ) Bulletin No. 82-00A Suitable For: Ammonia, Fluorocarbons, Nitrogen and Carbon Dioxide Features ASTM 352 LCB Cast Steel
More informationCONN in mm in mm in mm SIZE lbs kg PX " /4"
ccessories 1 PV MNUL IR VENT PRESSURE / TEMPERTURE ombination Manual ir Vent and Pressure/Temperature Test Port with brass body, dual durometer EPDM core, blowout-proof stem, side discharge vent with 1/8
More information611H Flo-Con Pressure Regulators & Valves
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding 611H Flo-Con Regulators & Valves Catalog F-2, February 2012 Page 2
More informationHigh Pressure Valves, Fittings and Tubing Pressures to 65,000 psi
igh Pressure Valves, ittings and Tubing MXMTOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed
More informationFlow Controls & Accessories
Flow ontrols & ccessories Section V V Flow ontrol Valves SPF Series...2 337 Series...3 3250 Series... 4-5 Miniature Right ngle...6 3251 Series...7 FM701 & FM703 Series...8 F701, F702, FS701 Series...9
More informationSection 1800 Index CHAIN LUBRICATION SHANK BRUSH DISPENSERS...22 Consist of a central oiler with single or multiple feed valves.
Section 800 Index HIN LURITION...8 General and engineering data helpful in determining your lubricating requirements. SHNK RUSH ISPENSERS... onsist of a central oiler with single or multiple feed valves.
More informationModel 912. Model 913: Full nozzle design. Bronze/brass body and bonnet. 316 SS trim (base, disc and disc holder).
Models, 3, and SME Section VIII, ir/steam/gas/liquid, UV National oard ertified. lso available for Vacuum Service. PED ertified for Non-Hazardous Gas. pplications ir/gas compressors - intercoolers - aftercoolers.
More informationHigh Pressure Valves, Fittings and Tubing Pressures to 65,000 psi
igh Pressure Valves, ittings and Tubing MXMTOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed
More informationSubcritical CO 2 Innovations
March 2011 / CATALOG 744 Subcritical CO 2 Innovations Energy Conscious Products & Solutions for Supermarkets Subcritical CO 2 Innovations Energy Conscious Products & Solutions for Supermarkets CATALOG
More informationTemperature Sensors. How to Order Consult factory for pricing and lead time. Normally Open (Closed on temperature rise)
Temperature Sensors 0916 Normally Open (losed on temperature rise) ontact Rating 6 MPS T 120 V 4 MPS T 240 V Voltage 0.1 to 240 volts or 12 VD 8 MPS, 24 VD 4 MPS Pressure 1,000 PSI operating Material 303
More informationBooster Pump Control Valve
MODEL 60-7 660-7 ooster Pump Control Valve Simple Hydraulic Operation Low Head Loss Horizontal or Vertical Mounting uilt-in Check Valve Proven Reliable Design The Cla-Val Model 60-7/660-7 ooster Pump Control
More informationR-22 R-404A/R-502/R-507A R-12/
EMERSON CLIMATE TECHNOLOGIES-System Protectors Recommended System Tonnage Take-Apart Liquid Line Filter Driers in Tons* Description, Low Temp. & Commercial Installations Air Conditioning Field Replacement
More informationQuick quarter-turn rotation. High cycle stem design. Integrated mounting pad for actuators. Compact assembly. Complete line of accessories.
36 Series Stainless Steel 2-way ull Port all Valve The 36 is a full port, 36 stainless steel, 3 piece ball valve. t is available with threaded ends (36N), socket weld ends (36S), or quick clamp ends with
More informationDZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A
DZ11TA ommercial 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/13-13.5 IEER /3.3 OP/R-410A ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Expanded Heating Data...12
More informationHydronic Specialties AFLB Series Specifications Automatic Pressure Independent Flow Limiter w/ Ball Valve
FL Series Specifications utomatic Pressure Independent Flow Limiter w/ all Valve : FL - - High : FL - High - Low : FL - High - 2" U.S. Patent No. 8,061,195 PRODUT DESRIPTION: The FL is an utomatic Pressure
More informationSOUTHWEST OILFIELD PRODUCTS, INC.
SOUTHWEST OILFIEL PROUTS, IN. MU PUMP EXPENLE PRTS LIST SOUTHWEST OL STYLE 876- FLUI EN FOR NTIONL -P-60 MU PUMP PERFORMNE HRT PUMP MX MX STROKE LINER SIZE IN INHES MOEL I.H.P. S.P.M. LENGTH ½ 5 5 ¼ 5
More informationIndustrial Refrigeration Control Valves
limate& Industrial ontrols Industrial Refrigeration ontrol Valves Refrigerating Specialties ivision ased on over 75 years of experience in industrial refrigeration, the Refrigerating Specialties ivision
More informationSOUTHWEST OILFIELD PRODUCTS, INC.
SOUTHWEST OILFIEL PROUTS, IN. MU PUMP EXPENLE PRTS LIST OEM STYLE 8475-5 FLUI EN FOR GRNER ENVER PZ-8 PUMP MX MX STROKE LINER SIZE IN INHES MOEL I.H.P. S.P.M. LENGTH 4 4 /2 5 5 ¼ 5 ½ 5 ¾ 6 6 ¼ 6 ½ 6 ¾
More informationProduct Guide MAS CA 08/05
Product Guide MS 8/5 www.mastewart.com ontents series ball valves -1: full/large port, 2 piece, NPT 1.1-2: full port, 2 piece, solder end 1.1-3: full port, 2 piece, NPT 1.2-4: full port, 2 piece, solder
More informationP95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients
PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil
More informationIndustrial Refrigeration Control Valves. Catalog C12
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Industrial Refrigeration Control Valves Catalog C Refrigerating Specialties
More informationPG-HHS
www.watts.com PG-HHS Watts Quality Sets the Standard in Hydronics With Watts hydronic products, you get longer valve life, economical control of heating and cooling zones, energy savings for your customers
More informationB1F. B Series Forged Brass Ball Valves 5.1
** Suitable for use with natural gas, manufactured gas and liquefied petroleum gases (distributed as vapour with or without the admixture of air), or mixtures thereof. Not for use on Sour Gas. Series Forged
More informationLiebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller
DISCONTINUED PRODUCT CSI 15621 - Mainframe Cooling Systems 1.1 SUMMARY Liebert CSU3000 CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller GUIDE SPECIFICATIONS 1.0 GENERAL These specifications describe
More informationLIGHTWEIGHT + COMPACT. Rotary Union Solutions SPS. Series NPT CONNECTION SIZE OPTIONS
LIGTWEIGT + OMPT Rotary Union Solutions Series NPT ONNETION SIZE OPTIONS ⅛" ½" ¼" ¾" ⅜" 1" Rotary Union Solutions ontents bout STI 3 What is a Rotary Union? 4 Series Overview 5 ow To Order 7 Specifi cations
More informationSmith Meter Truck Meter Packages Specifications
Issue/Rev. 0.4 (8/12) P Meter Smith Meter Truck Meter Packages Specifications ulletin SS01095 TP (Ticket Printer) LN (Large Numeral ounter) Preset ounter Air Eliminator/ Strainer Faucet P Meter Smith Meter
More informationINSTRUMENTATION BALL VALVES
INSTRUMENTTION LL VLVES INSTRUMENTTION LL VLVES ONSTRUTION 360 rass FETURES/ENEFITS PPLITIONS Panel pplications RNGES Vacuum Service Oxygen Service U.L. pproved for Refrigerant Service Maximum Pressure
More informationPiston Accumulators Series Catalog HY /US
Series 3000 Series 3000 Heavy uty Service with 3000 PSI Operating Pressure 2" thru 12" ores with Over 50 Standard apacities Patented V-O-ring Piston Seals Serviceable Threaded End onstruction Five Standard
More informationSOUTHWEST OILFIELD PRODUCTS, INC.
SOUTHWEST OILFIEL PROUTS, IN. MU PUMP EXPENLE PRTS LIST SOUTHWEST 8476-25 FLUI EN FOR NTIONL 12-P-160 MU PUMP PERFORMNE HRT PUMP MX MX STROKE LINER SIZE IN INHES MOEL I.H.P. S.P.M. LENGTH 4 ½ 4 ¾ 5 5 ¼
More informationPneumatic Fittings & Tubing
Pneumatic Fittings & Tubing General Information Fitting escriptions Working Pressure Style Maximum Nominal onstruction pplication ompatible Tubing Poly-Flo 500 PSI 125 PSI Three-piece: body, nut Pneumatic
More informationSOUTHWEST OILFIELD PRODUCTS, INC.
SOUTHWEST OILFIEL PROUTS, IN. MU PUMP EXPENLE PRTS LIST SOUTHWEST 8476-25LEW FLUI EN FOR LEWO W-1712 PUMP MX MX STROKE LINER SIZE IN INHES MOEL I.H.P. S.P.M. LENGTH 4 ½ 5 5 ½ 6 6 ½ 7 W-1712 1700 120 MU
More informationSporlan Thermostatic Expansion Valves
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Splan Thermostatic Expansion Valves ulletin 10-10, October 2009 t THERMOSTTI
More information910 Series Compact Control Valve
910 Series Compact Control Valve iaphragm ctuated CONTROL VLVES ctuator 7", 9", & 12" ctuator Sizes Heavy uty ie CastHousing 1/2" 6" Valve Sizes The Trerice 910 Series Pneumatic Control Valve offers high
More informationHeat Exchanger Accessories
TEMPERTURE CONTROL - SERIES 123W May be used directly to control small electric motors etc using SINGLE phase power supply to maximum of 6 amps. lso for low volt (12 or 24) DC power supplies to maximum
More informationEmergency Shear Valves
Emergency Shear Valves 0060 Underpump Emergency Valve The Emco Wheaton 0060 Emergency Shear Valve incorporates a replaceable shear section and a heat sensitive fusible link assembly. The valve can be manually
More informationHigh Pressure Valves, Fittings and Tubing Pressures to 65,000 psi (4,500 bar)
igh Pressure Valves, ittings and Tubing Pressures to psi (4,00 bar) MXMTOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality
More informationAdams. Progressive. Description. Typical system layout using Pneumatic Pump for grease - with monitoring. Typical system
45 P rogressive systems can be used for oil or grease lubrication when it is required to provide a positive displacement with visual or electrical monitoring. ll outlets can be checked by one indicator
More informationSeries TSB7 Ball Valve
Series TS7 all Valve leanflow TM TS7 all Valves are engineered to be a true process piping component to specifically meet the demanding processes found in the pharmaceutical and food & beverage industries.
More informationD I V I S I O N O F M A R S H B E L L O F R A M
PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil
More informationGround Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB
lamps Waterpipe Ground lamps Waterpipe Ground lamps Waterpipe Ground lamps 2-T Ground Wire Size Water Pipe Size 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, #2 WG 4 2-1/2
More informationMedium Pressure Valves, Fittings and Tubing Pressures to 21,000 psi
Medium Pressure Valves, ittings and Tubing MXIMTOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed
More informationROTORK FAIRCHILD MODEL T7500 LOW PRESSURE TRANSDUCER Installation, Operation and Maintenance Instructions
ROTORK FIRHIL MOEL T7500 LOW PRESSURE TRNSUER Installation, Operation and Maintenance Instructions Introduction The T7500 series low pressure transducer is a precision low pressure electropneumatic transducer
More informationSempell High Pressure Stop Valves Model VA500 (ASME)
7 Sempell High Pressure Stop Valves Designed for the isolation and control of high temperature and high pressure systems, this multipurpose globe valve can be used in a wide variety of applications. Features
More informationHigh-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability
High-Flow Stainless Tubes H11 ll stainless construction for high strength and durability Use with all PCS cascades J in part number indicates next largest thread TUE TUE L = 12 18 24 36 HF093T-.090.076
More informationInstrument Ball Valves
www.swagelok.com Instrument all s 40 Series On-off, switching, and crossover flow paths Working pressures up to 3000 psig (206 bar) Temperatures from 50 to 150 (10 to 65 ) Low-temperature service option
More informationZurn Wilkins Fire Protection Series. Backflow Preventers, Pressure Regulating Valves, and Water Control Products for Fire Sprinkler Applications
Zurn Wilkins ire Protection Series ackflow Preventers, Pressure Regulating Valves, and Water ontrol Products for ire Sprinkler pplications Zurn Wilkins ire Protection Series Zurn Wilkins fire protection
More informationSUPERIOR HVACR PRODUCTS CATALOG
HVACR PRODUCTS CATALOG R A SHERWOOD OD COMPANY SWD025 205 5S Sherwood od Valve, LLC LC MADE IN USA www.sherwoodvalve.com w wood od 888.508.258 8 58 A History of Quality and Innovation For nearly a century,
More informationModel B. Thermostatic Valves FEATURES APPLICATIONS FLOW RATES OF USGPM TAMPER-PROOF TEMPERATURE SETTINGS OF 55 F F
Model Thermostatic Valves FETURES FLOW RTES OF 68-1200 USGPM TMPER-PROOF TEMPERTURE SETTINGS OF 55 F - 240 F OMPLETELY SELF-ONTINED POSITIVE 3-WY VLVE TION VILLE IN ST IRON, DUTILE IRON, RONZE, STEEL,
More informationSporlan Thermostatic Expansion Valves
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Splan Thermostatic Expansion Valves RE atalogue 10-10 UK, pril 2010
More informationCombination Clutch/Brake
ombination lutch/brake For metalforming equipment Fast, smooth cycling ool running with higher torque ompact disc design Simple Installation Multiple mounting options for compatability with other competitive
More information3-Way Linked Globe Valve Assemblies with Linear Series Actuators
Linked Globe Valve ssemblies with Linear Series ctuators Note: hoose a valve assembly having a close-off pressure capability sufficient for the application. Not all valve body and actuator combinations
More informationCABLE-DRIVEN PNEUMATIC ROTARY ACTUATOR
R LE-RIVEN PNEUTI ROTRY TUTOR ajor enefits Exceptionally low profile for confined spaces Three bore sizes and two standard rotations, 90 and 180 Standard internal shock pad eliminates metal to metal contact,
More informationBACKFLOW PREVENTERS DUAL-CHECK BACKFLOW PREVENTER WITH ATMOSPHERIC VENT T/S-459 Certified to ASSE Standard 1012
CKFLOW PREVENTERS DUL-CHECK CKFLOW PREVENTER WITH TMOSPHERIC VENT T/S-459 Certified to SSE Standard 1012 Certified to CS Standard 64.3 Forged brass construction Threaded or sweat true union end connections
More informationBRASS BALL VALVES. CSA, UL, cul CGA 9.1 and FM Approved. Female NPT, Male NPT and Flare ends in various configurations from 3/8 to 1.0.
195 Series Ball Valves BRASS BALL VALVES CSA, UL, cul CGA 9.1 and FM Approved. Female NPT, Male NPT and Flare ends in various configurations from 3/8 to 1.0. Hot forged brass body Blow-out nickel plated
More informationREPLACEMENT PARTS DIRECTOVALVE AA344AE-2/3 & AA344AEC-2/3. Code 4 A
REPLCEMENT PRTS BLL VLVES SOLENOID VLVES DIRECTOVLVE 344E-2/3 & 344EC-2/3 ITEM STOCK NO. MFG. NO. DESCRIPTION PRICE E. 1 1236 CP20113-PP Cover $ 11.43 2 1237 20122-1-SS Motor #344E 254.58 2 1238 20122-3-SS
More informationCAST STEEL CATALOG.
ST STEEL TLOG www.walworthmx.com INEX Introduction WLWORTH Engineering ontrol...5 WLWORTH Quality System...5 Quality ontrol Equipment...9 ast Steel Gate, Globe and Swing heck Valves ST STEEL OLTE ONNET
More informationINSTALLATION INSTRUCTIONS FOR EXPOSED GEM 2 PISTON TYPE WATER CLOSET AND URINAL FLUSHOMETERS
ode No. 0816178 Rev. (04/07) INSTLLTION INSTRUTIONS FOR EXPOSE GEM PISTON TYPE WTER LOSET N URINL FLUSHOMETERS loset Flushometer for 1½ Top Spud MOELS 110/111, 115 & 136 Urinal Flushometer for 1¼ Top Spud
More informationF200 SERIES COMPRESSED AIR FILTERS
pril 2012 P/N 432-10016- INSTLLTION, OPERTION & MINTENNE INSTRUTION F200 SERIES OMPRESSE IR S PROUT PURPOSE & FUNTION: Van ir's F200 series filters are designed to remove contaminants from compressed air
More informationROBERT H. WAGER COMPANY. Installation, Operation and Maintenance Guide. Models 1500/1500-MC 1700/1750
ROERT H. WGER COMPNY Installation, Operation and Maintenance Guide Models 00/00-MC 00/0 MODELS 00/00-MC/00/0 Installation, Operation and Maintenance Guide Robert H. Wager Company, Inc. 0 Montroyal Road