Emergency Shear Valves

Size: px
Start display at page:

Download "Emergency Shear Valves"

Transcription

1 Emergency Shear Valves 0060 Underpump Emergency Valve The Emco Wheaton 0060 Emergency Shear Valve incorporates a replaceable shear section and a heat sensitive fusible link assembly. The valve can be manually operated to facilitate dispenser maintenance and incorporates a 3/8 test port. The closing poppet assembly is positioned out of the fuel flow path to minimize pressure drop. The 0060 can utilize a standard three boss mounting arrangement and includes U-bolt mounting hardware. Now available in single or double poppet variants. Mounting Hardware Included UL listed ody: Cast Iron Spring: Stainless Steel Seal: Viton Viton is a registered trademark of DuPont Dow Elastomers. Model No. Description Inlet Outlet Weight ¼2 Single Poppet Female Union 5.0 lbs ¼2 Single Poppet Female Male 4.0 lbs ¼2 Single Poppet Female Female 4.0 lbs ¼2 Single Poppet Female SP Male SP 4.0 lbs ¼2 Single Poppet Female SP Female SP 4.0 lbs ¼2 Double Poppet Female Male 4.2 lbs ¼2 Double Poppet Female Female 4.2 lbs ¼2 Double Poppet Female SP Male SP 4.2 lbs ¼2 Double Poppet Female SP Female SP 4.2 lbs Optional Items: No. Description Outlet Weight ¼2 Replacement Top; 1 Poppet Union 2.4 lbs ¼2 Replacement Top; 1 Poppet Male 1.4 lbs ¼2 Replacement Top; 1 Poppet Female 1.4 lbs ¼2 Replacement Top; 1 Poppet Female SP 1.4 lbs ¼2 Replacement Top; 1 Poppet Male SP 1.6 lbs ¼2 Replacement Top; 2 Poppets Male 1.6 lbs ¼2 Replacement Top; 2 Poppets Female 1.6 lbs ¼2 Replacement Top; 2 Poppets Male SP 1.6 lbs ¼2 Replacement Top; 2 Poppets Female SP 1.6 lbs Fusable Link Kit 0065 Mounting Kit The Emco Wheaton 0065 Mounting Kit is used to mount the 0060 to the dispenser pan stabilizer bar. The kit includes 2 U-bolts, 4 lock washers, 4 hex nuts, 3 socket head counter-sunk screws and mounting plate. 34

2 Emergency Shear Valves 0061 Underpump Emergency Valve The Emco Wheaton 0061 Emergency Shear Valve incorporates all of the features of the 0060 plus a universal mounting plate and hardware for easy installation in any dispenser sump or pan. The top shear section is completely independent of the lower assembly and can be replaced without disturbing the poppet seal. UL listed Secondary poppet hold open to reduce flow restriction Poppet seat independent of top shear section for extra safety during top replacement Integral mounting plate (mounting hardware included) Compact design gives extra working room in crowded containment chambers 2.25 VLVES & FITTINGS ody: Cast Iron Spring: Stainless Steel Seal: Viton Viton is a registered trademark of DuPont Dow Elastomers. Mounting Model No. Description Inlet Outlet Weight Plate Width ¼2 Single Poppet Female Male 9.3 lbs ¼2 Single Poppet Female Female 9.0 lbs ¼2 Double Poppet Female Male 9.3 lbs ¼2 Double Poppet Female Female 9.0 lbs Optional Items: No. Description Outlet Weight ¼2 Replacement Top; 1 Poppet Male 2.9 lbs ¼2 Replacement Top; 1 Poppet Female 2.6 lbs ¼2 Replacement Top; 2 Poppets Male 2.9 lbs ¼2 Replacement Top; 2 Poppets Female 2.6 lbs. 35

3 Vents 0084 Pressure Vacuum Vent The Emco Wheaton 0084 is an internal pressure vacuum valve that restricts vapor escape during product drops. It meets all regulatory codes requiring the installation of pressure vacuum vents. The is UL listed. Model No. Inlet Pressure Setting Vacuum Setting Weight H 2 0 (8.00oz.) 0.8 H 2 0 (0.50oz.) 1.7 lb (Int l) 2 Clamp on H 2 0 (8.00oz.) 0.8 H 2 0 (0.50oz.) 1.0 lb H 2 0 (1.14oz.) 3.0 H 2 0 (1.88oz.) 1.7 lb Clamp on 2.00 H 2 0 (1.14oz.) 3.0 H 2 0 (1.88oz.) 1.7 lb Viton is a registered trademark of DuPont Dow Elastomers. ody: luminum Seal: Viton Cap: Polyethlene 0084 ll Metal Pressure Vacuum Vent The Emco Wheaton 0084 is an internal pressure vacuum valve that restricts vapor escape during product drops. The body and cap are anodized aluminum for corrosion-free service. Model No. Inlet Pressure Setting Vacuum Setting Weight SP H 2 0 (8.00oz.) 0.8 H 2 0 (0.50oz.) 2.0 lb SP H 2 0 (8.00oz.) 3.0 H 2 0 (1.88oz.) 2.0 lb H 2 0 (1.73oz.) 8.0 H 2 0 (5.00oz.) 2.0 lb Clamp On 3.00 H 2 0 (1.73oz.) 8.0 H 2 0 (5.00oz.) 2.0 lb Clamp On 2.00 H 2 0 (1.14oz.) 0.8 H 2 0 (0.50oz.) 2.0 lb H 2 0 (1.14oz.) 3.0 H 2 0 (1.88oz.) 2.0 lb Clamp On 2.00 H 2 0 (1.14oz.) 3.0 H 2 0 (1.88oz.) 2.0 lb H 2 0 (8.00oz.) 0.8 H 2 0 (0.50oz.) 2.0 lb Clamp On H 2 0 (8.00oz.) 0.8 H 2 0 (0.50oz.) 2.0 lb ody: luminum Seal: Viton Cap: luminum 4103 Upward V Vent The Emco Wheaton 4103 Upward V Vent utilizes a straight-up V design to rapidly disperse vapors. Slip-on style vent attaches to the pipe with three screws for easy installation. Removable feature permits cleaning of the screen. Designed in accordance with NFP 30 and UL listed. Model No. Inlet Weight & 2 Polyethylene 0.7 lbs luminum 2.2 lbs Downward Mushroom Vent The Emco Wheaton 0785 Downward Mushroom Vent is designed for downward venting of storage tanks. The 40 mesh brass screen can be easily removed for cleaning. The 0785 threads onto either 1.5 or 2.0 inch vent lines. Clear coated aluminum for corrosion-free service. Model No. Inlet Weight & 2 Female luminum 1.0 lbs & 2 Female SP luminum 1.0 lbs

4 Vents 9803 ST Emergency Vent The Emco Wheaton 9803 Emergency Vent consists of a body and a cap that moves vertically on a center pin. Internal tank pressure forces the cap upward, venting tank pressure, then automatically resets when the pressure returns to the preset level. Opening Vent Capacity Model No. Inlet Pressure 2.5 PSI Weight Female 8oz. 95, lbs M 4 Male 8oz. 95, lbs Female 8oz. 194, lbs M 6 Male 8oz. 194, lbs ody: Cast Iron Cap: Cast Iron Seal: rass Valves & dapters 0031 Riser Extension The Emco Wheaton 0031 is designed to compensate for height variances due to tank settlement and heaving. Model No. Size Weight Ductile Iron 2.4 lbs Ductile Iron 3.6 lbs VLVES & FITTINGS 0066 Multi-Purpose Check Valve The Emco Wheaton 0066 Multi-Purpose Check Valve is designed to maintain prime and prevent unnecessary tripping of mechanical leak detectors. Model No. Size Weight rass 1.8 lbs Extractor Pipe Cap The Emco Wheaton ar Style Extractor Pipe Cap is designed to thread directly on the extractor access pipes. Requires the ar Style Extractor Wrench. Model No. Size Gasket Weight Female luminum una-n 0.8 lbs

5 Fill Caps & dapters 0097 Tight Fill Cap The Emco Wheaton Top Seal Fill Cap is designed for use on conventional 0030 or coaxial 0089 and 0096 dapters. The cap is lockable and features a self-aligning, toggle-action design with center collar to prevent breakage. Cams are brass, links are stainless steel, seal is una-n. The Emco Wheaton and -333 Top Seal Fill Caps are lockable lever action cam and groove type caps for use on 3 fill adapters. Gray color coded. Model No. Size pplication Weight Gray P.E.T. 4 Cam & Groove Domestic 1.2 lbs luminum 3 Cam & Groove Domestic 0.8 lbs luminum 3 Cam & Groove European 0.8 lbs Tight Fill dapter The Emco Wheaton 0030 dapter is designed for use with conventional or dual point fill systems. Features recessed threads and a buna gasket. Model No. Thread Size dapter Size Weight rass 3 Female NPT 3 Cam & Groove 1.2 lbs rass 3 Female SPP 3 Cam & Groove 1.2 lbs lum 4 Female NPSM 4 Cam & Groove 1.5 lbs rass 4 Female NPSM 4 Cam & Groove 3.0 lbs rass 4 Female SPP 3 Cam & Groove 3.0 lbs Tight Fill Swivel dapter The Emco Wheaton dapter Swivel incorporates all the features of the 0030 dapter. The swivel feature prevents accidental loosening of threads. The is field serviceable; use o-ring kit Use the Emco Wheaton 0081 dapter Wrench for installation. Model No. Thread Size dapter Size Weight rass 4 Female NPSM 4 Cam & Groove 7.8 lbs , 0096 Coaxial Tight Fill dapters Emco Wheaton Coaxial Vapor Recovery dapters are designed for standard coaxial fill systems and coaxial systems with self-sealing vapor lines. Features recessed threads for easy installation and positive seating on riser pipes. Model No. Used With Size Weight luminum 4 Female NPSC 3.1 lbs luminum 4 Female NPSC 3.1 lbs

6 Vapor Caps & dapters 0099 Vapor dapter Cap The Emco Wheaton /003 Vapor dapter Cap features a cam system designed for Stage I vapor recovery dual point systems. The cap is made of corrosion resistant orange impregnated material for vapor line identification. Cams are brass; links are stainless steel. Seal is una-n. The Emco Wheaton /334 Vapor dapter Cap is a lockable lever action cam & groove type cap for 3 dual point vapor recovery systems. Orange color coded aluminum body with brass lever and una-n seal. The and -334 include a 12 chain to prevent loss or theft. Model No. Size Weight Orange P.E.T. 4 Cam & Groove 1.0 lb Orange P.E.T. 4 Cam & Groove 1.0 lb luminum 3 Cam & Groove 0.8 lb luminum 3 Cam & Groove 0.8 lb Vapor dapter The Emco Wheaton 0076 Vapor dapter is used in dual point fill systems on the vapor return line. It features a poppet design which seals off the vapor path, external lugs on the adapter body for easy installation, and a una-n gasket. The 0076 uses the 0099 Vapor Cap. Model No. Thread Size dapter Size Weight lum 3 Female NPSM 4 Cam & Groove 2.1 lbs lum 4 Female NPSM 4 Cam & Groove 3.2 lbs rass 4 Female NPSM 4 Cam & Groove 7.0 lbs lum 3 Female SPP 4 Cam & Groove 2.1 lbs lum 4 Female SPP 4 Cam & Groove 3.2 lbs Vapor Swivel dapter The Emco Wheaton Vapor dapter Swivel incorporates all the features of the The swivel feature prevents accidental loosening of threads. The is field serviceable; use o-ring kit Use the Emco Wheaton 0081 dapter Wrench for installation VLVES & FITTINGS Model No. Thread Size dapter Size Weight rass 4 Female 4 Cam & Groove 8.0 lbs Vapor dapter The Emco Wheaton Vapor dapter is used in dual point fill systems on 3 vapor return lines. It features a poppet design which seals off the vapor path and a una-n gasket. Uses the Vapor Cap. Model No. Thread Size dapter Size Weight luminum 3 Female SPPs 3 Cam & Groove 3.8 lbs

7 Suction System Components 0438 Foot Valve One Poppet The Emco Wheaton 0438 Foot Valve, with a single poppet design, is used in suction pump lines. It features all brass parts and flat seat and disc construction and uses a #8 mesh screen to filter out fuel line contaminants. Heavy-duty hex at the valve top facilitates installation. Model No. Outlet Weight rass 1 1 /2" Female 2.1 lbs rass 1 1 /2" Female SP 2.1 lbs rass 2" Female 4.1 lbs rass 2" Female SP 4.1 lbs Foot Valve Two Poppets The Emco Wheaton 0439 Foot Valve has the same proven features as the 0438, but features a double poppet design for added protection and increased service life. Model No. Outlet Weight rass 1 1 /2" Female 3.1 lbs rass 1 1 /2" Female SP 3.1 lbs rass 2" Female 5.8 lbs rass 2" Female SP 5.8 lbs ngle Check Valve One Poppet The Emco Wheaton 0454 is a single poppet angle check valve installed on suction pump lines. The 0454 features brass seat and disc. Model No. Inlet Outlet Weight Cast Iron 1 1 /2" Female 1 1 /2" Female 4.2 lbs Cast Iron 1 1 /2" F SP 1 1 /2" F SP 4.2 lbs Cast Iron 2" Female 2" Female 7.5 lbs Cast Iron 2" F SP 2" F SP 7.5 lbs ngle Check Valve Two Poppets The Emco Wheaton 0464 ngle Check Valve has the same features as the 0454, but features a double poppet design. Model No. Inlet Outlet Weight Cast Iron 1 1 /2" Female 1 1 /2" Female 9.3 lbs Cast Iron 1 1 /2" F SP 1 1 /2" F SP 9.3 lbs

8 Suction System Components 0732 Underpump Union Check Valve The Emco Wheaton 0732 Union Check Valve is inserted into a standard 1 1 /2 union to stop the loss of prime. ody is plastic; all other components are brass. The includes screen. Model No. Size Weight /2" 0.4 lbs /2" 0.4 lbs Shown as installed in union coupling 0850 Vertical Check Valve One Poppet Side ccess The Emco Wheaton 0850 is a single poppet vertical check valve installed on suction pump lines. Features brass disc and seat. Side plate access allows for inspection and replacement of components without disconnecting piping. Model No. Inlet Outlet Weight Cast Iron 1 1 /2" Female 1 1 /2" Female 7.8 lbs Cast Iron 1 1 /2" F SP 1 1 /2" F SP 7.8 lbs Vertical Check Valve VLVES & FITTINGS The Emco Wheaton 0855 is a vertical check valve installed on suction pump lines. The 0855 features brass disc and seat and is available in either single or double poppet. Model No. Inlet Outlet Weight Poppet rass 1 1 /2" F 1 1 /2" F 2.3 lbs Single rass 1 1 /2" F SP 1 1 /2" F SP 2.3 lbs Single rass 1 1 /2" F 1 1 /2" F 3.3 lbs Double rass 1 1 /2" F SP 1 1 /2" F SP 3.3 lbs Double 0893 Vertical Check Valve One Poppet The Emco Wheaton 0893 is a vertical check valve with a removable cage. The 0893 features a single self-sealing poppet. 5.3 Model No. Inlet Outlet Weight rass 1 1 /2" Female SPT 1 1 /2" Female SPT 4.3 lbs

9 Tools/Sealants 0560 Extractor Wrench Emco Wheaton Extractor Wrenches are required to install and remove the 0584 and 0585 pipe caps and appropriate angle check, foot, and float valve extractor cages. Two head styles are available - the historic Emco Wheaton uckeye style wrench and the , industry standard bar style wrench. Extractor Model No. Size Weight Pipe Cap Extractor Fitting uckeye 1 1 ¼2 8 lbs uckeye 2 8 lbs , ar Style 2 8 lbs dapter Wrench The 0081 dapter is a specially designed tool for installing Emco Wheaton fill adapters. Octagonal bottom and tee handles assure tight positive seating of the fitting. Model No. Weight Used On Steel 10 lbs , -024, -104, -124, , 0089, 0096 Z0838 nti-seize Joint Seal Emco Wheaton nti-seize Joint Seal is recognized as one of the most versatile compounds available for its excellent sealing properties. Perfectly suited for threaded connections of virtually any material, including aluminum to aluminum. Provides leakproof sealing for gasoline, oil and water line systems. Z0838 Joint Seal has a high viscosity which it retains throughout years of use without cracking or setting. Resistant to heat, cold and vibration. UL listed. Model No. Size Weight Z ¼2 pint 1 lb. 42

Overfill Prevention Valve

Overfill Prevention Valve Overfill Prevention Valve The Guardian A1100 Materials Description Body: Aluminum Floats: HDPE Seals: Viton Specifications Weight: 4.3 lbs. Diameter: 3.76 Length: 18.0 Approvals CARB ULC City of New York

More information

Sliding Seal & Brass Poppet Valves

Sliding Seal & Brass Poppet Valves Sliding Seal & rass Poppet Valves anually Operated Section PL / VL Series... 2-3 HV Valve... 4-5 Hand Operated Valves,... 6-7 utton Operated Valves...8 Hand / Cam utton Valves...9 leed Valve...10 old text

More information

Paint/Solvent/Dump Valve and Flow-Through Valve

Paint/Solvent/Dump Valve and Flow-Through Valve Instruction Sheet P/N 08573D Paint/Solvent/Dump Valve and Flow-Through Valve. Description See Figure. The paint/solvent/dump valve is a normally-closed valve that opens to trigger and/or dump coating material.

More information

Plumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs

Plumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs Plumbing Hale offers a wide variety of plumbing components to make the pump installation and operation easier for the OEM and End User. Hale controls allow for a clean and compact pump panel. Controls

More information

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System FUEL DISPENSING SYSTEMS Component Details SE-27 12V DC - 15 GPM Metered Tank-top Dispensing System 12V DC Electric Pump - 1 Inlet - 3/4 Outlet 3-Wheel Mechanical Meter 1 Automatic Nozzle, Swivel & Hose

More information

Bellows-Sealed Valves

Bellows-Sealed Valves www.swagelok.com ellows-sealed Valves Working pressures up to 1000 psig (68.9 bar) Temperatures up to 900 F (482 C) 1/4, 3/8, 1/2, and 3/4 in.; 6, 10, and 12 mm end connections rass, stainless steel, and

More information

TRANSPORT YOU CAN TRU S T PRODUCT CATALOG

TRANSPORT YOU CAN TRU S T PRODUCT CATALOG TRANSPORT SOLUTIONS YOU CAN TRU S T PRODUCT CATALOG Table of Contents Tank Franklin Fueling Systems Tank product line is comprised of an extensive line of products for both loading and off loading applications.

More information

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System FUEL DISPENSING SYSTEMS Component Details SE-37 120V AC - 20 GPM Metered Tank-top Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter 1" Automatic Nozzle, Swivel

More information

check valves BIVCO Check Valves

check valves BIVCO Check Valves BIVCO valves are considered all-purpose valves because they can be tailored in the right combination of materials for the job at hand for liquids, including acids, alkalais, formaldehyde, solvents, oils,

More information

Model Model 815

Model Model 815 Model 600004 Model 600204 Model 85387 Model 600104 Model 815 ir line products and accessories ir couplers and nipples............................... 196 low guns, tire inflators and siphon sprayers.............

More information

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS Low Pressure Filters Low pressure filters are the most common type of filter found in hydraulic circuits used most often in return line applications. Low Pressure Filters Donaldson low pressure filters

More information

FAX: QUICK DISCONNECTS

FAX: QUICK DISCONNECTS Dry Disconnect Couplings Dry Disconnect Couplings Series 700D Series 600AN The Kamvalok dry disconnect coupling continues to be the standard of the industry. It provides automatic closure from both directions

More information

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System FUEL DISPENSING SYSTEMS Component Details SE-47 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter in Cabinet 1 Automatic

More information

General information about underground storage tank (UST) fueling systems in every day language.

General information about underground storage tank (UST) fueling systems in every day language. What this document contains: General information about underground storage tank (UST) fueling systems in every day language. What you need to know about Texas Commission on Environmental Quality (TCEQ)

More information

Valves, Fittings, and Manifolds Catalog. We make things MOVE

Valves, Fittings, and Manifolds Catalog. We make things MOVE Valves, Fittings, and Manifolds Catalog We make things MOVE We Make Things Move A forward-thinking innovator, Bimba provides industry-leading pneumatic, hydraulic and electric motion solutions that are

More information

ROBERT H. WAGER COMPANY. Installation, Operation and Maintenance Guide. Models 1500/1500-MC 1700/1750

ROBERT H. WAGER COMPANY. Installation, Operation and Maintenance Guide. Models 1500/1500-MC 1700/1750 ROERT H. WGER COMPNY Installation, Operation and Maintenance Guide Models 00/00-MC 00/0 MODELS 00/00-MC/00/0 Installation, Operation and Maintenance Guide Robert H. Wager Company, Inc. 0 Montroyal Road

More information

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A WATTS INDUSTRIES, INC. Technical Data SD 4512A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 4512A/9806 T124/T134 PILOT FRONT VIEW 2 1 /16 F 5 7 /8 2 3

More information

We also have literature pieces available in Spanish. These items can be downloaded from our Spanish Website at

We also have literature pieces available in Spanish. These items can be downloaded from our Spanish Website at Established in 1855, Morrison Bros. Co. is among the oldest private manufacturing firms in the Midwestern United States. Throughout the last century, the Morrison tradition grew and today the company is

More information

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data Worldwide Contacts www.tyco-fire.com Model CV-FR Grooved-End Riser Check Valves Inch to Inch (DN0 to DN00) General Description The TYCO Model CV-FR Grooved- End Riser Check Valve is a compact and rugged

More information

High-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability

High-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability High-Flow Stainless Tubes H11 ll stainless construction for high strength and durability Use with all PCS cascades J in part number indicates next largest thread TUE TUE L = 12 18 24 36 HF093T-.090.076

More information

Installation for L1100, L1200, L1200N Series Liquid Level Switches and DVU150, DVU175, and DVU2105/2115/2120 Series Dump Valves. GENERAL INFORMATION

Installation for L1100, L1200, L1200N Series Liquid Level Switches and DVU150, DVU175, and DVU2105/2115/2120 Series Dump Valves. GENERAL INFORMATION Installation for L1100, L1200, Series Liquid Level Switches and DVU150, DVU175, and DVU2105/2115/2120 Series Dump Valves. A =1-1/2 NPT B =2 NPT Meets NACE standard MR-01-75 for direct exposure to H2 S

More information

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications Page 1 of 11 1. DESCRIPTION The Viking Model F-2 Dry Pipe Valve is a latching differential valve used to separate the water supply from the dry pipe sprinkler system. The valve combines a positive latching

More information

Introduction to Constant Level Lubrication

Introduction to Constant Level Lubrication C Introduction to Constant Level Lubrication Constant level oilers are designed to maintain a predetermined oil level in a sump, which is necessary for proper lubrication. If the oil level were to drop

More information

225 CARTRIDGE DUAL SEAL

225 CARTRIDGE DUAL SEAL 225 CARTRIDGE DUAL SEAL MECHANICAL SEAL INSTALLATION INSTRUCTIONS PREPARATION 1 2 500.010" 0,25 mm 3 4.32 µ" 0,8 µm R a 1000 + ±.001".002" 0,025mm 0,050mm CAUTIONS These instructions are general in nature.

More information

Cast Iron Liquid Relief Valves

Cast Iron Liquid Relief Valves Cast Iron Liquid Relief Valves Features Bolted bonnet permits easy inspection and servicing without removal from system. Quality cast iron body and bonnet, insert and disc are available in either bronze

More information

316 Series Engine Driven DESCRIPTION MAINTENANCE SHIM ADJUSTMENT. Specifications Information and Repair Parts Manual

316 Series Engine Driven DESCRIPTION MAINTENANCE SHIM ADJUSTMENT. Specifications Information and Repair Parts Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

P-250 Rev. G P.D. Oscillating Piston Flowmeters: 2" Type 4-MT and MTSC Petroleum 2" Type 4D-MT LP Gas. Parts List for Petroleum and LPG Truck Meters

P-250 Rev. G P.D. Oscillating Piston Flowmeters: 2 Type 4-MT and MTSC Petroleum 2 Type 4D-MT LP Gas. Parts List for Petroleum and LPG Truck Meters P-250 Rev. G P.D. Oscillating Piston Flowmeters: 2" Type 4-MT and MTSC Petroleum 2" Type 4D-MT LP Gas Parts List for Petroleum and LPG Truck Meters Type 4-MT Air Release 1 15 8 7 9 14 11 16 13 6 17 2 3

More information

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port. Control Valves & Valve Accessories PNEUMADYNE, INC. Catalog 00 Phone 76-559-077 Fax 76-559-0547 Features Single stem design Compact size Four input options Numerous porting configurations Fully ported

More information

SECTION 8 Fire Protection

SECTION 8 Fire Protection Bronze Wet Barrel Fire Hydrants With over 100 years of experience on the west coast the heart of the wet barrel market James Jones Company, LLC is the innovator in the bronze wet barrel hydrant industry.

More information

Railroad Tank Car Equipment

Railroad Tank Car Equipment Railroad Tank Car Equipment AAR Approved Relief Valves for Railroad Tank Cars A8890-Series AAR Approval #PRD-039009 Suitable for use on pressurized railroad tank cars with a variety of liquified gasses

More information

Introduction. Installation. Maintenance. Bill of Materials

Introduction. Installation. Maintenance. Bill of Materials Table of Contents Introduction Specitications... 3 Operation... 4 Installation New Installations... 6 Retrofit Installations... 6 Flow Control Switch... 7 Dimensions... 8 E-7 Valve... 28 E-7 Valve with

More information

Pressure Relief Valve Maintenance Manual

Pressure Relief Valve Maintenance Manual Technical Manual 1098T Pressure Relief Valve Maintenance Manual Farris Engineering Division of Curtiss-Wright Flow Control Corporation TABLE OF CONTENTS - Manual Revision 0 Introduction & Safety Tips...

More information

Valves & Flow Control Components Valves & Flow Control Components

Valves & Flow Control Components Valves & Flow Control Components Section 4 Valves & Flow ontrol omponents Valves & Flow ontrol omponents... 106 SJ-200 Low-Profile utterfly Valve... 107 SJ-300N utterfly Valve... 108 SJ-300F utterfly Valve (for Fire Protection)... 110

More information

ISO 9001 : Full Port Check Valves. Male NPT, Plain & Grooved End Lowest Pressure Drop. Maximizing the Flow

ISO 9001 : Full Port Check Valves. Male NPT, Plain & Grooved End Lowest Pressure Drop. Maximizing the Flow ISO 9001 : 2008 Full Port heck Valves Male NPT, Plain & Grooved End Lowest Pressure Drop Maximizing the Flow Full Port Lowest Pressure Drop Quick Delivery Full Port, Lowest Pressure Drop Full Port heck

More information

ColVic Tanker Fittings

ColVic Tanker Fittings Tanker Fittings tanker fittings for fuel tankers are designed and manufactured by to accepted industry standards. All the fittings have full product and installation support and are available at short

More information

MARINE. Diesel Fuel/Water Separators. Installation. Operation. Parts. Service Information

MARINE. Diesel Fuel/Water Separators. Installation. Operation. Parts. Service Information Diesel Fuel/Water Separators stallation Operation Parts Service formation INSTALLATION A. Filter Mounted Above Fuel Storage Tank. Select a location in the fuel line between the fuel tank and the fuel pump,

More information

D I S T R I B U T E D V A L V E S. NAVCO Series E Resilient Seat Butterfly Valve NAVCO

D I S T R I B U T E D V A L V E S. NAVCO Series E Resilient Seat Butterfly Valve NAVCO NVCO Series E Resilient Seat utterfly Valve NVCO SERIES E RESILIENT SET UTTERFLY VLVE Features vailable in sizes 2 in. - 24 in. (50 mm - 600 mm) 200 psi 2 in. - 12 in. (50 mm - 300 mm) 150 psi 14 in. -

More information

BRUTE II 4-VALVE Manifold

BRUTE II 4-VALVE Manifold gauges Leak Detectors Detectors 20 BRUTE II 4-VALVE Manifold The Brute II 4-Valve Test Charging Manifold provides the flow that s proven faster than any conventional manifold. The aluminum alloy is forged

More information

2 PETROLEUM AND LP-GAS TANK TRUCK METERS

2 PETROLEUM AND LP-GAS TANK TRUCK METERS TS-250 Rev. E Refined Fuels PD Meters Size 2 Type 4-MT & 4D-MT 2 PETROLEUM AND LP-GAS TANK TRUCK METERS 2 4-MT with Air Release, Strainer, Printing Register and Preset Valve 2 4D-MT with Vapor Release,

More information

12 French Drive Mono, ON Canada L9W 5W1 Ph Toll Free Fax

12 French Drive Mono, ON Canada L9W 5W1 Ph Toll Free Fax CONTROL HANDLES AND ELECTRONIC METERS 12 French Drive Mono, ON Canada L9W 5W1 Ph. 519-942-8800 Toll Free 1-800-252-5636 Fax 519-942-4799 info@appliedlubrication.com oil Electronic meter RAASM s electronic

More information

Description. Rhino SD2/XD2 Follower Modules

Description. Rhino SD2/XD2 Follower Modules Rhino SD/XD Follower Modules Description See Figure. The follower module attaches onto the hydraulic section of the pump (). It is designed to force material out of straight-sided containers. Standard

More information

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX: TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: +353 66 7121911 FAX: +353 66 7124503 e-mail: sales@tillotson.ie SERIES SERVICE MANUAL INTRODUCTION The gasoline engine industry

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15100 VALVES PART 1 DESIGN DIRECTIVE 1.1 SUMMARY A. This Section includes general duty valves common to most mechanical piping systems, special duty valves are specified in individual piping system

More information

ISO Wafer Check Valves. Full Port Lowest Pressure Drop. Maximizing the Flow

ISO Wafer Check Valves. Full Port Lowest Pressure Drop. Maximizing the Flow ISO 9001-2008 Wafer Check Valves Full Port Lowest Pressure Drop Maximizing the Flow Full Port Lowest Pressure Drop Quick Delivery Full Port, Lowest Pressure Drop Full Port Wafer Check Valves provide more

More information

VACUUM CUPS 2 SECTION 2 VACUUM CUPS 2: EDCO USA.

VACUUM CUPS 2 SECTION 2 VACUUM CUPS 2: EDCO USA. VACUUM S SECTION VACUUM S 01 EDCO USA. www.edcousa.net :1 VACUUM S CONTENTS BELLOWS S (B) DOUBLE BELLOWS S (B) BELLOWS TRACTION FOOT S (BF) MULTI-BELLOWS S (BL) DEEP S (D) FLAT S (F) FLAT CONCAVE S (FC)

More information

Valve Selection. 1. Function and service considerations

Valve Selection. 1. Function and service considerations 1. Function and service considerations Valve Selection Selection Valves serve the purpose of controlling the fluids in building services piping. Valves are produced in a variety of design types and materials.

More information

SECTION VALVES PART 1 - GENERAL

SECTION VALVES PART 1 - GENERAL 1.01 RELATED DOCUMENTS SECTION 15100 VALVES PART 1 - GENERAL A. The work in this section includes the furnishing and installation of all control valves and accessories shown on the construction plans and

More information

O-Ring Swivel Joints

O-Ring Swivel Joints O-Ring Swivel Joints O-Ring Parts Identification List 1. O-ring (dust) seal 2. ball retainer screw 3. O-ring (pressure) seal 4. grease fitting 5. ball bearings O-Ring he O-ring pressure seal ensures a

More information

LUBRICATION & FLUID HANDLING ACCESSORIES. Heavy duty knurled steel barrel with large threads for easy loading.

LUBRICATION & FLUID HANDLING ACCESSORIES. Heavy duty knurled steel barrel with large threads for easy loading. hand grease guns Lever type The tough high pressure cast iron head makes Pro-Master Grease Guns unique in comparison to common pot metal or other die cast heads with a head burst pressure of 17,000 PSI

More information

F Series Terminators and Accesories

F Series Terminators and Accesories F Series Terminators and ccesories Our "F" series terminators are passive electronic circuitry designed to block 60 cycle and terminate RF signals on unused equipment ports. They are necessary to prevent

More information

Oil Metering Valve. Information and rebuild instructions. #905005

Oil Metering Valve. Information and rebuild instructions. #905005 Sig Marine Products #407-204 Cayer St. Coquitlam B.C. Canada V3K 5B1 www.sigmarine.com info@sigmarine.com T: 800 659 9768 Oil Metering Valve Information and rebuild instructions. #905005 Do not plug the

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Elbow This is an Electric Fuel Pump.

More information

Clay & Bailey Mfg. Co.

Clay & Bailey Mfg. Co. Clay & Bailey Mfg. Co. OIL EQUIPMENT PRICE LIST 2015 Effective: February 9, 2015 Applicable for Aboveground Storage Tank Equipment Underground Storage Tank Equipment Service Station Equipment D. O. T.

More information

Worldwide Contacts.

Worldwide Contacts. Worldwide Contacts www.tyco-fire.com DV-5 Remote-Resetting, Pressure-Reducing Deluge Valve, Limited Space Valve Cabinet General Description The TYCO DV-5 Remote-Resetting, Pressure-Reducing Deluge Valve,

More information

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT WATEROUS FIRE HYDRANT DUCTILE IRON 250 P.S.I.G. WATEROUS FIRE HYDRANT AMERICAN FLOW CONTROL It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT CONSTRUCTION WATEROUS FIRE HYDRANT TWO PIECE OPERATING

More information

Clay & Bailey Mfg. Co.

Clay & Bailey Mfg. Co. Clay & Bailey Mfg. Co. OIL EQUIPMENT PRICE LIST 2018 Effective: June 1, 2018 Applicable for Aboveground Storage Tank Equipment Underground Storage Tank Equipment Service Station Equipment D. O. T. Manholes

More information

2 PETROLEUM AND LP-GAS TANK TRUCK METERS

2 PETROLEUM AND LP-GAS TANK TRUCK METERS TS-250 Rev. D Refined Fuels PD Meters Size 2 Type 4-MT & 4D-MT 2 4-MT with Air Release, Strainer, Printing Register and Preset Valve 2 PETROLEUM AND LP-GAS TANK TRUCK METERS 2 4D-MT with Vapor Release,

More information

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications 1 of 9 1. DESCRIPTION The Viking Flow Control Valve is a quick opening, differential diaphragm flood valve with a spring loaded floating clapper. The Flow Control Valve can be used to facilitate manual

More information

B-2000 INSTALLATION GUIDE AND MAINTENANCE INSTRUCTIONS

B-2000 INSTALLATION GUIDE AND MAINTENANCE INSTRUCTIONS B-2000 INSTALLATION GUIDE AND MAINTENANCE INSTRUCTIONS S. Bravo Systems, Inc. 2929 Vail Avenue. Commerce, CA 90040 (323) 888-4133 FAX: (323) 888-4123 E-mail: info@sbravo.com http://www.sbravo.com IMPORTANT!

More information

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM INSTALLATION AND MAINTENANCE OF TOP LOADING ARM D TABLE OF CONTENTS 1. INTRODUCTION 04 2. SPECIFICATION OF THE REDLANDS LOADING ARM 04 3. INSTALLING THE LOADING ARM 3.1. Installation Procedures 05 4.

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

Butterfly Valves. watts.com

Butterfly Valves. watts.com Butterfly Valves watts.com Durafil is a registered trademark of Cargill, Limited. Teflon is a registered trademark of the E.I. Dupont de Nemours & Company, Incorporated. Uniseal is a registered trademark

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS A4005EVR Balance Vapor Recovery Nozzle RA4005EVR = Rebuilt XXX = Scuff Guard Color Permanent ID Information: Emco Logo on Boot Connector Emco Logo on Scuff Model No. on Spout Emco Wheaton Security Rivet

More information

Description. Rhino SD2/XD2 Follower Modules

Description. Rhino SD2/XD2 Follower Modules Rhino SD/XD Follower Modules Description See Figure. The follower module attaches onto the hydraulic section of the pump (). It is designed to force material out of straight-sided containers. Standard

More information

Pneumatic Fittings & Tubing

Pneumatic Fittings & Tubing Pneumatic Fittings & Tubing General Information Fitting escriptions Working Pressure Style Maximum Nominal onstruction pplication ompatible Tubing Poly-Flo 500 PSI 125 PSI Three-piece: body, nut Pneumatic

More information

ABOVEGROUND STORAGE TANK PRODUCTS CATALOG

ABOVEGROUND STORAGE TANK PRODUCTS CATALOG NEW PRODUCTS! ABOVEGROUND STORAGE TANK PRODUCTS CATALOG NEW UL Listing! High Flow Emergency Vents Emergency Valves Overfill Prevention Valves Audible Alarms Spill Containment Box Overfill Prevention Valves

More information

CASH VALVE SERIES FR BACK PRESSURE VALVES

CASH VALVE SERIES FR BACK PRESSURE VALVES Diaphragm actuated valves designed for either continuous or intermittent operation which provide accurate, repetitive pressure control FEATURES GENERAL APPLICATION For use on practically all fluids and

More information

Rhino VE Follower Modules

Rhino VE Follower Modules Instruction Sheet P/N 08 0 Description See Figure. The follower module attaches onto the hydraulic section of the pump (). It is designed to force material out of straight-sided containers. Follower plate

More information

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet) Flow Control 500a DESCRIPTION The Viking 1-1/2 is a quick opening, differential type flood valve with a spring loaded rolling diaphragm clapper. The can be used to facilitate manual or automatic on/off

More information

HYDROSTATIC TEST SYSTEM MANUAL

HYDROSTATIC TEST SYSTEM MANUAL PDQC HYDROSTATIC TEST SYSTEM MANUAL Technical Specification Operating Instructions Part List Revised 12-2016 Manual # PDQC- 6,000 And PDQC-10,000 1 PDQC PERFORMANCE DATA Model Number Maximum Pressure Volume

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-12/HF, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Pump Outlet Elbow Nozzle

More information

Quicklub Lubrication Systems Fittings, Adapters and Accessories

Quicklub Lubrication Systems Fittings, Adapters and Accessories Divider Valve Mounting Accessories 24646 Valve mounting bracket 5304 4" nylon locknut for valve mounting 247023 Grade 8, 4" valve mounting bolt 239499 Template for divider valve mounting (6, 8, 0 and 2

More information

Lab Specialty Products Technical Information TECHNICAL INFORMATION WEIGHTS & DIMENSIONS

Lab Specialty Products Technical Information TECHNICAL INFORMATION WEIGHTS & DIMENSIONS Lab Specialty Products Technical Information TECHNICL INFORMTION WEIGHTS & DIMENSIONS Contact Spears for any Information not found. Page 569 Lab Ball s Sample Engineering Specification ll thermoplastic

More information

O-Rings. Back pressure may be required to reseal the valves with nominal cracking pressure of 5psi or lower.

O-Rings. Back pressure may be required to reseal the valves with nominal cracking pressure of 5psi or lower. Check Valves SPCV Series Features Fixed cracking pressure. Pressure rating up to 3000 psig @70 (21 ) Temperature rating up to 375 (191 ) with Viton O-Ring. Variety of end connections available. Every valve

More information

RA-20 Paint/Solvent/Dump Valve

RA-20 Paint/Solvent/Dump Valve Instruction Sheet P/N 74B0 RA-0 Paint/Solvent/Dump Valve Description The paint/solvent valve is a normally closed valve used to trigger coating material. The valve may be used alone to actuate paint or

More information

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1 Packaged Pump Sets for Diesel/Fuel Oil Application Page 1 Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION Packaged Pump Sets for Diesel/Fuel Oil Application Page 2 Description Simplex SPS Series Packaged

More information

SECTION VALVES

SECTION VALVES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections:

More information

Pneufit Inch Series Push-In Tube Fittings 1/8" to 1/2" Tube Sizes UNF to 1/2" NPT Thread Options

Pneufit Inch Series Push-In Tube Fittings 1/8 to 1/2 Tube Sizes UNF to 1/2 NPT Thread Options Section 1 Pneufit Inch Series Push-In Tube Fittings to 1/2" Tube Sizes 10-32 UNF to 1/2" NPT Thread Options Inch Series Product Numbering System..................FIT-1-2 Inch Series Shapes and odes.........................fit-1-3

More information

SECTION FACILITY FUEL - NATURAL GAS PIPING AND SYSTEMS

SECTION FACILITY FUEL - NATURAL GAS PIPING AND SYSTEMS SECTION 23 11 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Fuel Pipe and Pipe Fittings - General 2. Steel Pipe and Fittings, Above Grade 3. Steel Pipe and Fittings, Below Grade 4. Polyethylene

More information

TECHNICAL DATA 1-1/2 (dn40)

TECHNICAL DATA 1-1/2 (dn40) July 1, 2011 Deluge Valves 209a DESCRIPTION The Viking Model E-3 1-1/2 Deluge Valve is a quick-opening, differential type flood valve with a rolling diaphragm clapper. The deluge valve is used to control

More information

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section.

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section. SECTION 23 05 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Gate Valves 2. Balancing Valves 3. Ball Valves 4. Butterfly Valves 5. Swing Check Valves 1.2 RELATED SECTIONS A. Contents of Division

More information

Sanitary Fittings & Valves. Quick-Connect Couplers. Male Quick-Connect Couplers. Female Quick-Connect Couplers

Sanitary Fittings & Valves. Quick-Connect Couplers. Male Quick-Connect Couplers. Female Quick-Connect Couplers Quick-Connect Couplers These Quick-Connect couplers are ideal for compressed gas applications due to their unique eight stainless steel ball bearing seal system, which prevents leaks. They are machined

More information

Stage I Vapor Recovery Testing

Stage I Vapor Recovery Testing Stage I Vapor Recovery Testing Results of Testing for NESHAP Regulations 40CFR63 Part CCCCCC ASTSWMO Conference March 2, 2011 Brad Hoffman Outline Overview of NESHAP Regulation and Equipment Requirements

More information

SERIES. CRYOGENIC/PRESSURE BUILD REGULATOR 3/8 and 1/2" NPT, BSPT Inlet 400 Psig (28 Bar) Description

SERIES. CRYOGENIC/PRESSURE BUILD REGULATOR 3/8 and 1/2 NPT, BSPT Inlet 400 Psig (28 Bar) Description CRYOGENIC/PRESSURE BUILD REGULATOR 3/8 and 1/2" NPT, BSPT Inlet 400 Psig (28 Bar) CR Description The Generant Series CR Cryogenic Regulator provides high flow during Cryogenic Vessel Pressure Build function

More information

$1.50 $3.00 U.S. &adaptors chart

$1.50 $3.00 U.S. &adaptors chart $.50 $.00 U.S. &adaptors chart Our trained Quality Assurance Personnel follow a rigid inspection program to ensure that our fittings meet or surpass the strictest requirements of SAE. Quality Assurance

More information

CNG Products. Receptacles, Ball & Check Valves Filters, Tube Fittings. ECE R110 & AGA / CGA NGV Compliant for NGV application. 100% factory tested

CNG Products. Receptacles, Ball & Check Valves Filters, Tube Fittings. ECE R110 & AGA / CGA NGV Compliant for NGV application. 100% factory tested www.hy-lok.com Catalog No. H-CNG100 April 2014 CNG Products Receptacles, all & Check Valves Filters, Tube Fittings ECE R110 & AGA / CGA NGV Compliant for NGV application. 100% factory tested 2007, 2014

More information

FLOW CONTROLLERS Instrument/Analyzer Products. Catalog 4513/USA April 2003

FLOW CONTROLLERS Instrument/Analyzer Products. Catalog 4513/USA April 2003 FLOW CONTROLLERS Instrument/Analyzer Products Catalog 4513/USA April 2003 FLOW CONTROLLERS Instrument/Analyzer Products Catalog 4513/USA April 2003 table of contents SC420 Series............. 1-2 SC423XL

More information

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C This additive injection system was designed to be used with five gallon jug of additive. The system is supplied

More information

M-5000TG/5700TG Steam and Cold Water Mixing Unit

M-5000TG/5700TG Steam and Cold Water Mixing Unit M-5000TG/5700TG Steam and Cold Water Mixing Unit Installation, Operating and Maintenance Instructions Last Updated: October, 2012 Strahman Valves, Inc. USA Headquarters 2801 Baglyos Circle Bethlehem, PA

More information

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING SECTION 220523 - GENERAL-DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Schroeder Check Test Point System

Schroeder Check Test Point System Section 1: Introduction Schroeder Check test points provide a fast easy and safe way to test pressures up to 10,000 psi (680 bar) in hydraulic systems under operation. They are available in both 1620 (M16x20)

More information

Marine Fuel Filtration. Marine FBO. Features:

Marine Fuel Filtration. Marine FBO. Features: The Racor assembly is specifically designed to meet the filtration requirements of today s high pressure common rail diesel injection systems. The unit is used for fuel dispensing pumps or as a primary

More information

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11 Page 1 of 11 1. DESCRIPTION The Viking Model F-1 Dry Pipe Valve is a latching differential valve used to separate the water supply from the dry pipe sprinkler system. The valve combines a positive latching

More information

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C ulletin 617 Rev. Model R ommercial Riser Riser Manifold for ommercial pplications ulletin 617 Rev. vailable Sizes/Pressure Ratings: 1 1 / 2 (40mm) and 2 (50mm) Threaded - 250 psi (17,2 bar) Working Pressure

More information

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent CARB Phase I Enhanced Vapor Recovery AST Certified Products 5 (VR-402-B) Sensor Pressure Vacuum 0 Monitoring Clock Gauge Direct Fill Spill Container Dust Cap 9 2 Overfill Prevention Gauge Stick Port Suction

More information

Pneumatic and Electronic Motion Control Distributor AIROYAL COMPANY airoyalcompany.net Ph: Fax:

Pneumatic and Electronic Motion Control Distributor AIROYAL COMPANY airoyalcompany.net Ph: Fax: COMPANY Pneumatic and Electronic Motion Control Distributor AIROYAL COMPANY airoyalcompany.net Ph: 973-761-4150 Fax: 973-761-5731 Quick Valves Disconnect Table of Contents Index Table of Contents Ball

More information

quick couplings HQC Series Instrumentation Quick Couplings Typical Applications Features & Benefits Technical Data

quick couplings HQC Series Instrumentation Quick Couplings Typical Applications Features & Benefits Technical Data HQ Series Instrumentation Quick ouplings Typical pplications Laboratories University labs Gas distribution iopharmaceutical Technical Data ONSTRUTION 36 Stainless steel* NOMINL FLOW SIZES /4, 3/8, / MXIMUM

More information

HOKE. Needle. Valves. Union Bonnet. Severe Service. Needle DYNA-PAK STEM PACKING SYSTEM PROCHEM INSTRUMENTATION HOKE INSTRUMENTATION VALVES

HOKE. Needle. Valves. Union Bonnet. Severe Service. Needle DYNA-PAK STEM PACKING SYSTEM PROCHEM INSTRUMENTATION HOKE INSTRUMENTATION VALVES PROHM INTRUMNTTION HOK INTRUMNTTION VLV HOK Needle Valves Needle evere ervice Union onnet HOK valves are available with GYROLOK compression fitting ends HOK manufactures a complete line of precision needle

More information

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING SUNY GENESEO 220523-1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

M-5000TG/5700TG Steam and Cold Water Mixing Unit

M-5000TG/5700TG Steam and Cold Water Mixing Unit M-5000TG/5700TG Steam and Cold Water Mixing Unit Installation, Operating and Maintenance Instructions Last Updated: August, 2014 Strahman Valves, Inc. USA Headquarters 2801 Baglyos Circle Bethlehem, PA

More information