3 -color/2-screen display

Size: px
Start display at page:

Download "3 -color/2-screen display"

Transcription

1 3-Color Display Digital Flow Switch for Water Series 3 -color/2-screen display RoHS IP65 Main screen Sub screen Note 3) Main screen Instantaneous flow rate Note ) Sub screen Set value Note 3) Instantaneous flow rate Note ) ccumulated value Peak/ottom value Line name Fluid temperature Note 2) Note ) Main screen shows the instantaneous flow rate only. Note 2) Fluid temperature can be displayed only when the digital flow switch with a temperature sensor is selected. Note 3) Sub screen can be turned off. Flow range: Line up 25 L type PF2 Integrated flow adjustment valve and temperature sensor Flow adjustment valve Remote type PVC piping type Remote sensor unit Temperature sensor Remote type 3-color display Digital flow monitor pplicable fluid: Deionized water, chemical, etc. Integrated type and remote type added to series. 329

2 Digital Flow Switch for Water 4% smaller than current product Reducing piping space Shortened 5 3 PF2W74-3 (Current product) Straight piping length PF2W74 Current product requires a straight piping length at least 8 times the piping diameter. Refer to straight piping length and accuracy. (pages 336 and 345) Flow adjustment valve Temperature sensor Display range: to C Space saving and reduced piping labor (Temperature sensor alone) Minimum setting unit: C nalog output: Current output/voltage output Temperature sensor Temperature display Fluid temperature: to 9 C Ethylene glycol aqueous solution can be used Example) Flow control of the circulating fluid in a chiller Customer s machine Rotatable display Display can be rotated in increments of 45 to suit the installation conditions. Easy operation, improved visibility. Counterclockwise 9 Clockwise 225 IN 35 turn OUT OUT (No rotation) Non-grease OUT IN IN 8 turn Mounting racket mounting Direct mounting Panel mounting Front protective cover Tapping screw (4 pcs.) 33 9 turn Panel mount adapter Waterproof seal (accessory) Panel Mounting screw (M3 x 8 L) (accessory)

3 Measured flow rate Variations pplicable fluid Type Integrated Remote sensor Monitor PVC piping Integrated type Remote Rated flow range (L/min) INDEX Flow adjustment valve/temperature sensor Port size Flow Flow adjustment None adjustment Temperature valve Temperature Rc, NPT, G sensor valve sensor.5 to 4 3/8 Water 2 to 6 3/8, /2 Ethylene glycol aqueous solution 5 to 4 /2, 3/4 Deionized water sensor 25 L/min added Chemical Monitor Series to 3/4, 5 to 25 4, 2 to 25 3 to Color Display Digital Flow Switch for Water How to Order 332 Specifications (Integrated Display) 333 Specifications (Remote Sensor Unit) 334 Flow Rate Characteristics (Pressure Loss) 336 Wetted Parts Construction 337 Dimensions color display Digital flow monitor can copy to up to switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing labor risk of mistakes in setting 3-Color Display Digital Flow Switch for PVC Piping Copy How to Order 343 setting Minimizing Made toorder 342 Master sensor Slave side unit (source of copy) (copy destination) 2 units Specifications (Integrated Display) 344 units Specifications (Remote Sensor Unit) 345 Wetted Parts Construction 346 Dimensions 347 Made to Order 349 Indicator Visually check status of sensor via indicator. Reducing wiring labor by connector e-con connector No tools and peeling required 3-Color Display Digital Flow Monitor for Water 3 How to Order 35 Specifications 35 Dimensions 353 Flow rate: Low linking green/slow OFF Rated flow or more Red ON PVC piping type PF2 linking green/fast Rated flow or less M8 connector Flow rate: High Power supply/output connection lead wire Wetted Parts Pipe CPVC (Heat resistant PVC) Function Details 354 ody PPS pplicable Fluid 357 Seal FKM 33

4 3-color display Digital Flow Switch for Water Series How to Order RoHS Remote sensor unit Output specification/temperature sensor OUT OUT2 Temperature For how to order of Symbol Flow rate Temperature sensor remote monitor unit, nalog to 5 V refer to page 35. None 2 nalog 4 to 2 m T nalog to 5 V nalog to 5 V With temperature sensor Symbol Nil S Remote sensor unit Integrated display T T M Type Remote sensor unit Integrated display Rated flow range (Flow range) Symbol Rated flow range 4.5 to 4 L/min 2 2 to 6 L/min 4 5 to 4 L/min to L/min 2 5 to 25 L/min Flow adjustment valve With/without flow Rated flow range adjustment valve 4 None Yes Note ) External input: The accumulated value, peak value, and bottom value can be reset. Note 2) For units with temperature sensor, only OUT2 can be set as either temperature output or flow rate output. Setting when shipped is for temperature output. Options/Part No. 2 To use in combination with remote monitor (3 series), select analog output of to 5 V of flow rate (output symbol - or -T ). Note) nalog output of 4 to 2 m with temperature sensor is made to order. (Refer to page 342.) Thread type Nil Rc N NPT F G ISO228 equivalent Port size Rated flow range Integrated display Output specification/temperature sensor OUT OUT2 Temperature Symbol Flow rate Flow rate Temperature sensor NPN PNP nalog to 5 V nalog 4 to 2 m None nalog to 5 V nalog 4 to 2 m External input Note ) External input Note ) (NPN) Note 2) NPN (PNP) Note 2) PNP (nalog to 5 V) Note 2) nalog to 5 V C D E F G H T T CT DT ET FT 4 NPN PNP NPN NPN PNP PNP NPN PNP NPN PNP NPN NPN PNP PNP 2 Note ) and 25 L/min types with flow adjustment valves are not available. Note 2) The flow adjustment valve of this product is not suitable for applications which require constant adjustment of flow rate. Symbol (nalog 4 to 2 m) (nalog to 5 V) (nalog 4 to 2 m) Port size 3/8 /2 3/4 / /4 / Note 2) nalog 4 to 2 m Note 2) nalog to 5 V Note 2) nalog 4 to 2 m When optional parts are required separately, use the following part numbers to place an order. Description Part no. Qty. Note racket Note) ZS-4-K ZS-4-L ZS-4-M For 74/72/54/52 For 74/54 For 7/5 With 4 tapping screws (3 x 8) With 4 tapping screws (3 x 8) With 4 tapping screws (4 x ) Lead wire with M8 connector ZS-4- Lead wire length (3 m) Note) For units with flow adjustment valve, 2 brackets are required With temperature sensor Written in both Japanese and English. The temperature sensor is not calibrated. racket (Option) Nil None racket R Made to Order X9 Seal material EPDM X28 nalog 4 to 2 m 2 output type Note) X43 Piping material brass Note) pplicable only for remote type with temperature sensor (Refer to page 342.) Calibration certificate (Only flow sensor) Nil None With calibration certificate Note) With bracket is not available for 25 L/min type. Integrated display/unit specification Symbol M G F J Remote sensor unit/unit printed on label Symbol Instantaneous flow rate Temperature Nil L/min C L/min G (gal/min) C/ F Under the New Measurement Law, units other than SI (symbol Nil ) cannot be used in Japan. Note) G: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] [L/min] F = 9/5 C 32 Instantaneous flow rate L/min gal/min gal/min L/min ccumulated flow L gal gal L Temperature C C F F Under the New Measurement Law, units other than SI (symbol M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] [L/min] F = 9/5 C 32 Lead wire Nil With lead wire with M8 connector (3 m) N Without lead wire with M8 connector

5 3-color display Digital Flow Switch for Water Series Specifications (Integrated Display) Refer to pages 22 and 23 for Flow Switch Precautions. For details about the Specific Product Precautions, refer to the Operation Manual on the SMC website, Model pplicable fluid Detection method Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex Rated flow range.5 to 4 L/min 2 to 6 L/min 5 to 4 L/min to L/min 5 to 25 L/min Display flow range.35 to 5.5 L/min.7 to 22. L/min 3.5 to 55. L/min 7 to 4 L/min 2 to 35 L/min (Flow under.35 L/min is displayed as. ) (Flow under.7 L/min is displayed as. ) (Flow under 3.5 L/min is displayed as. ) (Flow under 7 L/min is displayed as ) (Flow under 2 L/min is displayed as ) Set flow range.35 to 5.5 L/min.7 to 22. L/min 3.5 to 55. L/min 7 to 4 L/min 2 to 35 L/min Minimum setting unit. L/min. L/min L/min 2 L/min Conversion of accumulated pulse (Pulse width: 5 ms).5 L/pulse. L/pulse.5 L/pulse L/pulse 2 L/pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss (without flow adjustment valve) ccumulated flow range Note 4) Switch output to 9 C (with no freezing and condensation) Instantaneous flow rate: L/min, ccumulated flow: L Display value: ±3% F.S. nalog output: ±3% F.S. ±2% F.S. Note 2) ±5% F.S. (25 C reference) to MPa.5 MPa 45 kpa or less at the maximum flow L L y. L y.5 L y L to 7 C (with no freezing and condensation) 6 kpa or less at the maximum flow Maximum load current Maximum applied voltage Internal voltage drop Response time Note 2), 5) Output protection Output Flow rate mode Temperature Response time Note 6) nalog output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 7) Insulation resistance Standards and regulations Wetted parts material Note 8) Piping port size Note 9) Weight Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector 85 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 337. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. e aware that water leakage may happen due to internal seal shrinkage or swelling depending on kinds of fluid. Note 2) When.5 s is selected for the response time of the switch output, the repeatability becomes ±3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to page 335. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every 2 or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 24 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 6) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Note 7) When the temperature sensor is used, it will be 25 VC. Note 8) Refer to Wetted Parts Construction on page 337 for details. Note 9) When the piping diameter or piping passage is restricted, the specifications may not be satisfied. Note ) ny products with tiny scratches, smears, or display color variation or brightness which does not affect the performance are verified as conforming products. Temperature Sensor Specifications NPN or PNP open collector output 8 m 28 VDC NPN: V or less (at 8 m load current) PNP:.5 V or less (at 8 m load current).5 s/ s/2 s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. Select from hysteresis mode or window comparator mode..5 s/ s/2 s (linked with the switch output) Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer 2-screen display (Main screen: 4-digit, 7-segment, 2-color, Red/Green Sub screen: 6-digit, -segment, White) Display values updated 5 times per second Output, Output 2: Orange 2 to 24 VDC ±% 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 MΩ or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 2 g 285 g 3 g 385 g 3/8, /2 26 g 335 g 36 g 435 g /2, 3/4 4 g 53 g 6 g 73 g 3/4, 72 g 86 g /4, /2 89 g 75 g PF2 Rated temperature range Setting/Display temperature range Minimum setting unit Display unit Display accuracy nalog output accuracy Response time to C Note ) to C C C ±2 C ±3% F.S. 7 s Note 2) mbient temperature characteristics ±5% F.S. Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9 C. Note 2) The response time is for the temperature sensor alone. The output related to the temperature sensor is OUT2 only. Flow rate detecting circuit Temperature detecting circuit OUT Switch output OUT2 Switch output nalog output rown DC () lack OUT White OUT2 lue DC () The OUT2 can be selected from either the output for temperature or flow rate by button operation. 333

6 Series Specifications (Remote Sensor Unit) Refer to pages 22 and 23 for Flow Switch Precautions. For details about the Specific Product Precautions, refer to the Operation Manual on the SMC website, Refer to page 35 for monitor unit specifications. pplicable fluid Detection method Rated flow range Fluid temperature ccuracy Repeatability Temperature characteristics Operating pressure range Note 2) Proof pressure Note 2) Pressure loss (without flow adjustment valve) Response time Note 3) nalog output Voltage output Current output Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 4) Insulation resistance Standards and regulations Wetted parts material Note 5) Piping port size Note 6) Weight Model Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex.5 to 4 L/min 2 to 6 L/min 5 to 4 L/min to L/min 5 to 25 L/min to 9 C (with no freezing and condensation) to 7 C (with no freezing and condensation) ±3% F.S. ±2% F.S. ±5% F.S. (25 C reference) Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector Temperature Sensor Specifications to MPa Note 2).5 MPa 45 kpa or less at the maximum flow 6 kpa or less at the maximum flow s Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC For power supply status, flow rate indicator (linking speed changes in response to flow rate), and other error indicator 2 to 24 VDC ±% 3 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 MΩ or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 95 g 27 g 295 g 37 g 3/8, /2 245 g 32 g 345 g 45 g /2, 3/4 395 g 55 g 595 g 75 g 85 g 3/4, 75 g 84 g /4, /2 875 g 6 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 337. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. e aware that water leakage may happen due to internal seal shrinkage or swelling depending on kinds of fluid. Note 2) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Note 4) When the temperature sensor is used, it will be 25 VC. Note 5) Refer to Wetted Parts Construction on page 337 for details. Note 6) When the piping diameter or piping passage is restricted, the specifications may not be satisfied. Note 7) ny products with tiny scratches, smears, or display color variation or brightness which does not affect the performance are verified as conforming products. Rated temperature range nalog output accuracy Response time mbient temperature characteristics to C Note ) ±3% F.S. 7 s Note 2) ±5% F.S. Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9 C. Note 2) The response time is for the temperature sensor alone. Caution Sensor Set Flow Range and Rated Flow Range Set the flow within the rated flow range. The set flow range is the range of flow rate that is possible in setting. The rated flow range is the range that satisfies the sensor s specifications (accuracy etc.). lthough it is possible to set a value outside the rated flow range, the specifications will not be guaranteed even if the value stays within the set flow range. Flow range.5 L/min 2 L/min 5 L/min 2 L/min 4 L/min L/min 4 L/min 25 L/min 35 L/min.5 L/min.35 L/min.35 L/min 4 L/min 5.5 L/min 5.5 L/min 2 L/min.7 L/min.7 L/min 5 L/min 3.5 L/min 3.5 L/min L/min 7 L/min 7 L/min 2 L/min 2 L/min 2 L/min 2 L/min In the case of the 5 series, the displayable and settable ranges are the same as the 3 series flow monitor L/min 22 L/min 22 L/min 4 L/min 55 L/min 55 L/min 5 L/min 5 L/min L/min 4 L/min 4 L/min 25 L/min 35 L/min 35 L/min 25 L/min 28 L/min 28 L/min Rated flow range Display flow range Set flow range

7 3-color display Digital Flow Switch for Water Series nalog Output Flow rate/nalog output 4/6/4 C Output 25 C Voltage output V.5 V.4 V.8 V 5 V Current output 4 m 6 m 5.6 m 7.2 m 2 m Model Rated flow [L/min] Minimum Maximum 74/ / /54 7/5 5 4 Minimum rated flow 72/ MaximumFlow rate rated flow Fluid temperature/nalog output 7/5 Output Voltage output Current output Voltage output Current output.6 V 2.4 m C 5 V 2 m V 4 m D 5.4 V 2.6 m D C C C C C Fluid temperature Operating Pressure and Proof Pressure 74/72/74/54/52/54 Pressure [MPa] 7/5 Pressure [MPa] Proof pressure [MPa].8 Operating pressure [MPa] Fluid temperature [ C] Proof pressure [MPa].8.6 Operating pressure [MPa] Fluid temperature [ C] 74S/72S/74S/54S/52S/54S Pressure [MPa] /52 Pressure [MPa] Proof pressure [MPa] Operating pressure [MPa] Fluid temperature [ C] Operating pressure/ Proof pressure [MPa] Fluid temperature [ C] PF2 335

8 Series Flow Rate Characteristics (Pressure Loss: Without Flow djustment Valve) 74/54 72/52 74/ Pressure loss [MPa].3.2. Pressure loss [MPa].3.2. Pressure loss [MPa] Flow rate [L/min] 7/ Flow rate [L/min] 72/ Flow rate [L/min].4.5 Pressure loss [MPa].3.2. Pressure loss [MPa] Straight Piping Length and ccuracy (Reference Value) Straight piping length Flow rate [L/min] Flow rate [L/min] The smaller the piping size, the more the product is affected by the straight piping length. Fluid pressure has almost no affect. Low flow rate lessens the effect of the straight piping length. Use a straight pipe that is 8 cm or longer in length to satisfy the ±3% F.S. specification. ( cm or longer for L/min and 25 L/min types) Pressure:.3 MPa Pressure:.3 MPa 74/54 Piping diameter: ø2 72/52 Piping diameter: ø2 74/54 ± ±9 ±8 ±7 ±6 ±5 74/54-3 (at 4 L /min) ±4 ±3 ±2 ± ± Straight piping length [cm] Pressure:.3 MPa Piping diameter: 25 (Port size ) 7/5 2 (Port size 6) ccuracy [% F.S.] ccuracy [% F.S.] ±6 ±4 ±2 ± ±8 ±6 ±4 ±2 7/5-6 (at 5 L /min) 7/5-6 (at L /min) 7/5- (at L /min) 7/5- (at 5 L /min) ccuracy [% F.S.] Straight piping length [cm] Pressure:.3 MPa Piping diameter: 32 (Port size 2) 72/52 4 (Port size 4) ccuracy [% F.S.] ± ±9 ±8 ±7 ±6 ±5 ±4 ±3 ±2 ± ± ± ±9 ±8 ±7 ±6 ±5 ±4 ±3 ±2 ± 72/52-3 (at 6 L /min) 72/52-4 (at 6 L /min) 72/52-3 (at 8 L /min) 72/52-4 (at 25 L /min) 72/52-2 (at 25 L /min) ccuracy [% F.S.] Pressure:.3 MPa Piping diameter: ø6 ± ±9 ±8 ±7 ±6 ±5 74/54-4 (at 4 L /min) ±4 ±3 ±2 74/54-6 (at 4 L /min) ± ± Straight piping length [cm] ± Straight piping length [cm] No data for 4 cm, or for under 5 cm, as these cannot be used due to piping dimensions. 336 ± Straight piping length [cm]

9 3-color display Digital Flow Switch for Water Series Flow Rate Characteristics of Flow djustment Valve 74S/54S 72S/52S 74S/54S Flow rate [L/min] P =.5 MPa P =.4 MPa P =.3 MPa P =.2 MPa P =. MPa Number of rotations [rotations] P: Pressure differential between the front and the rear of product Measurable Range for Ethylene Glycol queous Solution (Reference Value) Flow rate [L/min] P =.3 MPa 5. P =.5 MPa P =.4 MPa P =.2 MPa P =. MPa Number of rotations [rotations] P: Pressure differential between the front and the rear of product Flow rate [L/min] 6 P =.5 MPa 5 P =.4 MPa P =.3 MPa P =.2 MPa P =. MPa Number of rotations [rotations] P: Pressure differential between the front and the rear of product queous solution concentration [%] (Weight) Measurable within this range queous solution temperature [ C] Wetted Parts Construction Component Parts No. Description ttachment 2 Seal 3 ody 4 Sensor q r w w Temperature sensor Temperature sensor body Flow adjustment valve body Flow adjustment valve cover Flow adjustment valve shaft Shaft support Y seal Cap seal e y Material SCS3 Stainless steel 34 FKM PPS PPS Stainless steel 34 Stainless steel 34 PPS PPS Stainless steel 34 PPS FKM FKM o i t w u!2! w! w Note Stainless steel 34 equivalent 74/72/74/7/54/52/54/5 72/52 With brazing JIS Z 326: g-7, ( ISO 3677: -g56cuznsn-62/65 ) 337 PF2

10 U U Series Internal Circuits and Wiring Examples 7 -(T) NPN (2 outputs) -E(T)/F(T) E(T): PNP nalog voltage output F(T): PNP nalog current output rown DC() rown DC() lack OUT White OUT2 lue DC() 2 to 24 VDC lack OUT White nalog output lue DC() 2 to 24 VDC -(T) PNP (2 outputs) rown DC() lack OUT White OUT2 lue DC() rown DC() lack OUT White nalog output lue DC() -C(T)/D(T) C(T): NPN nalog voltage output D(T): NPN nalog current output 2 to 24 VDC 2 to 24 VDC -G NPN External input rown DC() lack OUT White External input lue -H PNP External input DC() rown DC() lack OUT White External input lue DC() 2 to 24 VDC 2 to 24 VDC ccumulated pulse output wiring examples -(T)/C(T)/D(T)/G (T): NPN (2 outputs) C(T), D(T): NPN nalog output G: NPN External input lack OUT Max. 28 V 8 m -(T)/E(T)/F(T)/H (T): PNP (2 outputs) E(T), F(T): PNP nalog output G: PNP External input rown DC() White OUT2 (7--(T)- only) lue DC() lack OUT White OUT2 (7 (T) only) Max. 8 m V or 5 msec 5 msec V or 5 msec 5 msec 5 -/2 : nalog voltage output 2: nalog current output rown DC() -T nalog voltage output (With temperature sensor output) rown DC() kω lack to 5 V/4 to 2 m White N.C. lue DC() 2 to 24 VDC kω kω lack to 5 V Temperature sensor White to 5 V lue DC() 2 to 24 VDC 338

11 3-color display Digital Flow Switch for Water Series Dimensions 74/72/74/7/72 Integrated display Connector pin number Example 3 4 For 72 2 Pin no. Pin name DC () 2 OUT2 3 DC () 4 OUT G Z Y D.4 E F 2 x Piping port 3 5 S (35.5) H J T U 42 4 x WX V W IN OUT G K L 4 x P G 2 x Piping port N 54/52/54/5/52 Remote sensor unit Y F DD E J 3 V W For 52 G Z 2 x Piping port S T U H 42 (35.5) 4 x WX IN OUT PF2 G K L 4 x P G 2 x Piping port N Model 74/54 72/52 74/54 7/5 72/52 Port size (Rc, NPT, G) 3/8 3/8, /2 /2, 3/4 3/4, /4, /2 G /4 G / D DD E F G H J K L N P S 3.6 ø2.7 depth ø2.7 depth ø2.7 depth ø3.5 depth ø3.5 depth 4 T 22 racket dimensions U 32 V 4 W 5 WX Y (mm) Z

12 Series Dimensions 74/72/74/7/72--T Integrated display: With temperature sensor 54/52/54/5/52--T Remote sensor unit: With temperature sensor (mm) Model 74/54--T 72/52--T 74/54--T 7/5--T 72/52--T 72/52-F2-T 72/52-F4-T S/72S/74S Integrated display: With flow adjustment valve D S T 54S/52S/54S Remote sensor unit: With flow adjustment valve D S T Q Q F K L N F K L 4 x P 4 x P N (mm) Model 74S/54S 72S/52S 74S/54S (Max. 68.6) 63.6 (Max. 68.6) (Max. 8) D F K L N P ø2.7 depth ø2.7 depth ø2.7 depth Q ø9 ø9 ø28 Q number of rotations racket dimensions S T

13 3-color display Digital Flow Switch for Water Series Dimensions 74S/72S/74S--T Integrated display: With temperature sensor and flow adjustment valve 54S/52S/54S--T Remote sensor unit: With temperature sensor and flow adjustment valve D S D S K K Model 74S/54S--T 72S/52S--T 74S/54S--T (lack) 4 (lue) 3 M8 2 (White) (rown) ZS-4- Lead wire with M8 connector Pin no. Pin name Wire color DC () OUT2 DC () OUT rown White lue lack ø D K S (32.8) (mm) ø4 (3) (45) (5) Lead Wire Specifications Conductor Insulator Sheath Finished O.D. Note ) 4-wire type lead wire with M8 connector used for the series. Note 2) Refer to the Operation Manual in our website ( for wiring. Nominal cross section O.D. Material O.D. Color Material WG23 pprox..7 mm Heat resistant PVC pprox.. mm rown, White, lack, lue Heat and oil resistant PVC ø4 PF2 34

14 Series Made to Order Please contact SMC for detailed dimensions, specifications and lead times. Made to Order Seal material EPDM Seal material for wetted parts changed to EPDM Symbol -X9 5 7 X9 X9 Seal material EPDM Refer to How to Order, page 332 for details. Note) Not compatible with units with flow adjustment valve. Please special-order separately. 2 nalog 4 to 2 m 2 output Output specification of remote type with a temperature sensor: nalog 4 to 2 m 2 output Symbol -X28 5 2T X28 nalog 4 to 2 m 2 output Refer to How to Order, page 332 for details. Note) Remote monitor unit is eguipped as standard. 3 Piping material brass Piping (attachment) material changed to brass Symbol -X X43 X43 Piping (attachment) material brass Piping (attachment) Refer to How to Order, page 332 for details. Note) Not compatible with units with flow adjustment valve. Please special-order separately. Surface treatment is not applied on piping. 342

15 3-color display Digital Flow Switch for PVC Piping Series How to Order RoHS For how to order of remote monitor unit, refer to page 35. Remote sensor unit Integrated display Options/Part No. 5 7 Symbol 2 Remote sensor unit Output specification 5 U 7 U 25 M Type Remote sensor unit Integrated display Rated flow range (Flow range) Symbol Rated flow range to L/min 2 3 to 25 L/min Symbol 25 3 OUT nalog to 5 V nalog 4 to 2 m To use in combination with remote monitor (3 series), select analog output of to 5 V of flow rate (output symbol - ). Port size 25 3 Connection type U PVC pipe PVC pipe O.D. Rated flow range Pipe 2 O.D. 32 mm 38 mm JIS K6742 equivalent Integrated display Output specification Symbol OUT OUT2 NPN NPN PNP PNP C NPN nalog to 5 V D NPN nalog 4 to 2 m E PNP nalog to 5 V F PNP nalog 4 to 2 m G NPN External input H PNP External input External input: The accumulated value, peak value, and bottom value can be reset. Remote sensor unit/unit printed on label Symbol Instantaneous flow rate Nil L/min L/min G (gal/min) Under the New Measurement Law, units other than SI (symbol Nil ) cannot be used in Japan. Note) G: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] [L/min] Made to Order X9 Seal material EPDM (Refer to page 349.) racket (Option) Nil None racket R Lead wire Nil With lead wire with M8 connector (3 m) Calibration certificate (Only flow sensor) Nil None With calibration certificate Written in both English and Japanese. The temperature sensor is not calibrated. Note) With bracket is not available for 25 L/min type. Integrated display/unit specification Symbol Instantaneous flow rate ccumulated flow M L/min L G gal/min gal Under the New Measurement Law, units other than SI (symbol M ) cannot be used in Japan. Note) G: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] [L/min] N Without lead wire with M8 connector PF2 When optional parts are required separately, use the following part numbers to place an order. Description Part no. Qty. Note racket ZS-4-M For 7/5 With 4 tapping screws (4 x ) Lead wire with M8 connector ZS-4- Lead wire length (3 m) 343

16 Series Specifications (Integrated Display) Refer to pages 22 and 23 for Flow Switch Precautions. For details about the Specific Product Precautions, refer to the Operation Manual on the SMC website, Model pplicable fluid Detection method Rated flow range Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss ccumulated flow range Note 4) Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note 2), 5) Output protection Output mode Flow rate Response time Note 6) nalog output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Wetted parts material Note 7) Piping port size Note 8) Without lead wire with connector Weight 7 72 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to L/min 3 to 25 L/min 7 to 4 L/min 2 to 35 L/min (Flow under 7 L/min is displayed as ) (Flow under 2 L/min is displayed as ) 7 to 4 L/min 2 to 35 L/min L/min 2 L/min L/pulse 2 L/pulse to 7 C (with no freezing and condensation) Instantaneous flow rate: L/min, ccumulated flow: L, Display values updated 5 times per second Display value: ±3% F.S. nalog output: ±3% F.S. ±2% F.S. Note 2) ±5% F.S. (25 C reference) to MPa MPa 45 kpa or less at the maximum flow L y L NPN or PNP open collector output 8 m 28 VDC NPN: V or less (at 8 m load current) PNP:.5 V or less (at 8 m load current).5 s/ s/2 s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode..5 s/ s/2 s (linked with the switch output) Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer 2-screen display (Main screen: 4-digit, 7-segment, 2-color, Red/Green Sub screen: 6-digit, -segment, White) Output, Output 2: Orange 2 to 24 VDC ±% 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 MΩ or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease g 37 g With lead wire with connector 425 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 337. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 357. e aware that water leakage may happen due to internal seal shrinkage or swelling depending on kinds of fluid. Note 2) When.5 s is selected for the response time of the switch output, the repeatability becomes ±3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graph below. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every 2 or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 24 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. Note 6) The response time until the set value reaches 9% in relation to the step input. Note 7) Refer to Wetted Parts Construction on page 346 for details. Note 8) When the piping diameter or piping passage is restricted, the specifications may not be satisfied. Note 9) ny products with tiny scratches, smears, or display color variation or brightness which does not affect the performance are verified as conforming products. nalog Output Flow rate/nalog output C Output 2 C Voltage output V.4 V.5 V 5 V Current output 4 m 5.6 m 5.9 m 2 m Model 7/5 72/ Rated flow [L/min] Minimum Maximum 3 25 Minimum rated flow Maximum Flow rate rated flow 3 34 g Operating Pressure/Proof Pressure 7/72/5/52 (for PVC Piping) Max. operating pressure [MPa] Fluid temperature [ C]

17 3-color display Digital Flow Switch for PVC Piping Series Refer to pages 22 and 23 for Flow Switch Precautions. For details about the Specific Product Precautions, refer to the Operation Manual on the SMC website, Specifications (Remote Sensor Unit) Refer to page 35 for monitor unit specifications. Model pplicable fluid Detection method Rated flow range Fluid temperature ccuracy Repeatability Temperature characteristics Operating pressure range Note 2) Proof pressure Note 2) Pressure loss Response time Note 3) nalog output Voltage output Current output Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Wetted parts material Note 4) Piping port size Note 5) Without lead wire with connector Weight With lead wire with connector 5 52 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to L/min 3 to 25 L/min to 7 C (with no freezing and condensation) ±3% F.S. ±2% F.S. ±5% F.S. (25 C reference) to MPa Note 2) MPa 45 kpa or less at the maximum flow s Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC For power supply status, flow rate indicator (linking speed changes in response to flow rate), and other error indicator 2 to 24 VDC ±% 3 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 MΩ or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 337. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 357. Note 2) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. Note 4) Refer to Wetted Parts Construction on page 346 for details. Note 5) When the piping diameter or piping passage is restricted, the specifications may not be satisfied. Note 6) ny products with tiny scratches, smears, or display color variation or brightness which does not affect the performance are verified as conforming products. Flow Rate Characteristics (Pressure Loss) 7/5 Pressure loss [MPa] Straight Piping Length and ccuracy (Reference Value) Straight piping length Flow rate [L/min] 72/52 Pressure loss [MPa] /72/5/52 ± g 355 g Flow rate [L/min] Pressure:.3 MPa Piping diameter: 25, g 4 g PF2 Fluid pressure has almost no effect. To maintain ±3% F.S. in the specificatioins, use a straight pipe that is cm or longer in length. ccuracy [% F.S.] ±8 ±6 ±4 ±2 7/5-U25 72/52-U32 (at L/min) (at 25 L/min) ± Straight piping length [cm] For measurable range for ethylene glycol aqueous solution (reference values), refer to page

18 Series Wetted Parts Construction q t w e r w t Component Parts No Description PVC pipe Seal ody Sensor Material CPVC FKM PPS PPS Note Replacement Parts No. Description PVC pipe (25) PVC pipe (3) 25 retaining plate (M5 x 8 with two hexagonal socket head cap screws) 5 3 retaining plate (M5 x 65 with two hexagonal socket head cap screws) Part no. ZS-4-U25 ZS-4-U3 ZS-4-U25- ZS-4-U3- Qty. Replacing the PVC pipe may cause accuracy to fluctuate by to 2%. Internal Circuits and Wiring Examples Refer to page

19 3-color display Digital Flow Switch for PVC Piping Series Dimensions 7-U25 Integrated display x 25 IN (35.5) OUT ø x Example 3 4 Connector pin number 2 Pin no Pin name DC () OUT2 DC () OUT 4 x 3.5 depth 4 5-U25 Remote sensor unit ZS-4- Lead wire with M8 connector (lack) 4 (lue) 3 M8 2 (White) (rown) Pin no. Pin name Wire color DC () OUT2 DC () OUT rown White lue lack ø (32.8) 62.6 IN ø4 (3) Note ) 4-wire type lead wire with M8 connector used for the series. Note 2) Refer to the Operation Manual in our website ( for wiring. (45) (5) OUT Lead Wire Specifications Nominal cross WG23 Conductor section O.D. Material Insulator O.D. Color Sheath Material Finished O.D. pprox..7 mm Heat resistant PVC pprox.. mm rown, White, lack, lue Heat and oil resistant PVC ø4 347 PF2

20 Series Dimensions 72-U3 Integrated display x ody side Connector pin number (35.5) Pin no. Pin name DC () OUT2 DC () OUT Flow direction ø38 4 x 3.5 depth 4 52-U3 Remote sensor unit 2 x (35.5) ody side Connector pin number Pin no. Pin name DC () Not used DC () OUT Flow direction 348

21 Series Made to Order Please contact SMC for detailed dimensions, specifications and lead times. Made to Order Seal material EPDM Seal material for wetted parts changed to EPDM Symbol -X9 5 7 U U X9 X9 Seal material EPDM Refer to How to Order, page 343 for details. PF2 349

22 3-color display Digital Flow Monitor for Water 3 Series RoHS How to Order 3 3 Type Remote monitor unit For remote sensor units, select the analog output to 5 V type. pplicable sensors: 5--(T) Output specification Symbol OUT OUT2 C D E F G H NPN PNP NPN NPN PNP PNP NPN PNP NPN PNP nalog to 5 V nalog 4 to 2 m nalog to 5 V nalog 4 to 2 m External input External input J K nalog to 5 V nalog 4 to 2 m nalog to 5 V nalog 4 to 2 m In combination with remote sensor unit with temperature sensor, only OUT2 can be set for temperature sensor output. Lead wire With power supply/output connection lead wire (2 m) Nil Power supply/output connection lead wire ZS-4-W M V C Calibration certificate (Only flow monitor) Nil None With calibration certificate Written in both English and Japanese. Option 2 Nil C None Sensor connector ( pc.) Sensor connector (e-con) Connector is not connected, but shipped together. Option Nil T Waterproof seal (accessory) None Panel mount adapter Panel Panel mount adapter Mounting screw (M3 x 8 L) (accessory) N Without power supply/output connection lead wire Lead wire is not connected, but shipped together. Remote monitor unit/unit specification Symbol Instantaneous flow rate ccumulated flow Temperature M G F J L/min gal/min gal/min L/min L gal gal L C C F F Under the New Measurement Law, units other than SI (symbol M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] [L/min] F = 9/5 C 32 V Front protective cover Panel mount adapter Front protective cover Panel mount adapter Mounting screw (M3 x 8 L) (accessory) Waterproof seal (accessory) Panel Options/Part No. When optional parts are required separately, use the following part numbers to place an order. Description Part no. Note Panel mount adapter Front protective cover Panel mount adapter Front protective cover only Power supply/output connection lead wire Sensor connector (e-con) Lead wire with connector for copying ZS-26- ZS-26-C ZS-26- ZS-4-W ZS-28-C-4 ZS-4-Y With waterproof seal and screws With waterproof seal and screws Separately order panel mount adapter etc. Lead wire length (2 m) pc. Connect up to slave units 35

23 3-color display Digital Flow Monitor for Water 3 Series Specifications Refer to pages 22 and 23 for Flow Switch Precautions. For details about the Specific Product Precautions, refer to the Operation Manual on the SMC website, Model Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Display unit ccuracy Repeatability Temperature characteristics ccumulated flow range Note ) Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note 2) Output protection Output Flow rate Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. mode Temperature Select from hysteresis mode or window comparator mode. Response time Note 3) s/2 s (linked with the switch output) nalog output Voltage output Current output Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC Hysteresis External input Input/output Display method Indicator light Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer Input for copy mode 2-screen display (Main screen: 4-digit, 7-segment, 2-color, Red/Green Sub screen: 6-digit, -segment, White), Display values updated 5 times per second Output, Output 2: Orange Power supply voltage Current consumption Connection 2 to 24 VDC ±% 5 m or less Power supply output 5P connector, sensor connection 4P connector (e-con) Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Weight Without power supply/output connection lead wire With power supply/output connection lead wire 3.35 to 4.5 L/min.7 to 8. L/min 3.5 to 45. L/min 7 to 2 L/min 2 to 28 L/min (Flow under.35 L/min is displayed as. ) (Flow under.7 L/min is displayed as. ) (Flow under 3.5 L/min is displayed as. ) (Flow under 7 L/min is displayed as ) (Flow under 2 L/min is displayed as ).35 to 4.5 L/min.7 to 8. L/min 3.5 to 45. L/min 7 to 2 L/min 2 to 28 L/min. L/min. L/min L/min 2 L/min.5 L/pulse. L/pulse.5 L/pulse L/pulse 2 L/pulse Instantaneous flow rate: L/min, ccumulated flow: L Display value: ±.5% F.S. nalog output: ±.5% F.S. ±.5% F.S. ±.5% F.S. (25 C reference) L L y. L y.5 L y L NPN or PNP open collector output 8 m 28 VDC NPN: V or less (at 8 m load current) PNP:.5 V or less (at 8 m load current) s/2 s Short circuit protection IP4 (Only front face of the panel is IP65 when panel mount adapter and waterproof seal of optional parts are used.) to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 MΩ or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS 5 g g Note ) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every 2 or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 24 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 2) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Note 4) ny products with tiny scratches, smears, or display color variation or brightness which does not affect the performance are verified as conforming products. Temperature Sensor Specifications Rated temperature range Setting/Display temperature range Minimum setting unit Display unit nalog output accuracy Response time mbient temperature characteristics ±5% F.S. Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9 C. Note 2) The response time is for the temperature sensor alone. nalog Output Flow rate/nalog output 4/2/4 C Output 2 C Voltage output V.5 V.4 V.5 V 5 V Current output 4 m 6 m 5.6 m 5.9 m 2 m The values of vary according to the range. Model Flow rate [L/min] Minimum Maximum Minimum flow to C Note ) to C C C ±3% F.S. 7 s Note 2) Maximum Flow rate flow DC () rown Flow rate Remote to 5 V lack sensor Temperature to 5 V White unit DC () lue The output related to the temperature sensor is OUT2 only. The OUT2 can be selected from either the output for temperature or flow rate by button operation. Fluid temperature/nalog output Voltage output.6 V Current output 2.4 m V 4 m C D Voltage output 5 V 5.4 V Current output 2 m 2.6 m e sure to use in combination with remote sensor unit with temperature sensor. Output D C Remote monitor unit OUT Switch output nalog output OUT2 Switch output nalog output rown DC () lack OUT White OUT2 lue DC () C C C C Fluid temperature 35 PF2

24 U U 3 Series Internal Circuits and Wiring Examples - NPN (2 outputs) -G NPN External input rown DC() rown DC() lack OUT White OUT2 lue DC() 2 to 24 VDC lack OUT White External input lue DC() 2 to 24 VDC Gray Copy function, Input/Output Gray Copy function, Input/Output - PNP (2 outputs) rown DC() -H PNP External input rown DC() lack OUT White OUT2 lue DC() 2 to 24 VDC lack OUT White External input lue DC() 2 to 24 VDC Gray Copy function, Input/Output Gray Copy function, Input/Output -C/D C: NPN nalog voltage output D: NPN nalog current output -J/K J: nalog voltage output K: nalog current output rown DC() rown DC() lack OUT White nalog output lue DC() 2 to 24 VDC lack nalog output White nalog output lue DC() 2 to 24 VDC Gray Copy function, Input/Output Gray Copy function, Input/Output -E/F E: PNP nalog voltage output F: PNP nalog current output rown DC() lack OUT White nalog output lue DC() 2 to 24 VDC Gray Copy function, Input/Output ccumulated pulse output wiring examples -/C/D/G : NPN (2 outputs) C, D: NPN nalog output G: NPN External input lack OUT Max. 28 V 8 m -/E/F/H : PNP (2 outputs) E, F: PNP nalog output G: PNP External input rown DC() White OUT2 (3 only) lue DC() V or lack OUT White OUT2 (3 only) Max. 8 m V or msec 5 msec 5 msec 5 msec

25 NC/IN 3-color display Digital Flow Monitor for Water 3 Series Dimensions (7.5) 2.5 Sensor connector (4P) Front protective cover Panel mount adapter (2) Power supply/ output connector (5P) Panel fitting dimmensions pplicable panel thickness:.5 to 8 mm (Without waterproof seal).5 to 6 mm (With waterproof seal) 55 or more Front protective cover Waterproof seal x R or less Panel 48 or more Panel mount adapter Sensor connector Pin no. Terminal Connector no. Lead wire color q DC () rown q w N.C./IN 2 White (Not used/temperature sensor to 5 V input) w e DC () 3 lue e r INPUT 4 lack (Flow rate sensor to 5 V input) r When using the lead wire with M8 connector included with the 5 series Power supply/output connection lead wire Lead Wire Specifications Pin no. Nominal cross section WG26 Conductor 5 Gray COPY O.D. pprox..5 mm 4 White OUT2 3 lack OUT 2 lue DC () Material Insulator O.D. Color Cross-linked vinyl pprox.. mm rown, lue, lack, White, Gray rown DC () Sheath Material Oil and heat resistant vinyl 2 Finished O.D. ø PF2 Note) Refer to the Operation Manual in our website ( for wiring. 353

26 Series Function Details Integrated Display (7 series)/remote Monitor Unit (3 series) Output operation The output operation can be selected from the following: Output (hysteresis mode and window comparator mode) corresponding to instantaneous flow rate, Output corresponding to accumulated flow, ccumulated pulse output Note) t the time of shipment from the factory, it is set to hysteresis mode and normal output. When a temperature sensor is attached, the output to the temperature sensor is selectable only for OUT2. (Refer to How to Order for details.) Indication color The indication color can be selected for each output condition. The selection of the indication color provides visual identification of abnormal values. (The indication color depends on OUT setting.) Response time.5 seconds second 2 seconds ON: Green, OFF: Red ON: Red, OFF: Green lways: Red lways: Green Response time The response time can be selected depending on the application. ( second for default setting) bnormalities can be detected more quickly by setting the response time to.5 seconds. The effect of the pump fluctuation and flickering of the display can be reduced by setting the response time to 2 seconds. Note) The temperature sensor output is fixed to 7 seconds. pplicable model Integrated display Remote monitor unit 7 series 3 series Selection of display on sub screen The display on the sub screen in measuring mode can be set. External input function This function can be used when external input is available. The accumulated value, peak value, and bottom value can be reset by remote control. ccumulated flow external reset: This function resets the accumulated value to when an input signal is applied. In accumulated increment mode, the value will be zero when reset, and the accumulated value will increase from zero. In accumulated decrement mode, the value will be the set value when reset, and the accumulated value will decrease from the set value. When the accumulated value is memorized, every time the accumulated value external reset is activated, the memory element (EEPROM) will be accessed. Take into consideration the maximum number of times the memory element can be accessed, million times. The total of external input times and accumulated value memorizing time interval should not exceed million times. Peak and bottom reset: Peak and bottom values are reset. Forced output function Output is turned ON/OFF compulsorily when starting the system or during maintenance. This enables confirmation of the wiring and prevents system errors due to unexpected output. For the analog output type, the output will be 5 V or 2 m for ON and V or 4 m for OFF. lso, the increase or decrease of the flow and temperature will not change the on/off status of the output while the forced output function is activated. ccumulated value hold function ccumulated value can be saved on the unit even when the power supply is turned off. The accumulated value is memorized every 2 or 5 minutes during measurement, and continues from the last memorized value when the power supply is turned on again. The lifetime of the memory element is million access cycles. Take this into consideration before using this function. Sub screen Integrated display Remote monitor unit Set value display ccumulated value display Peak value display ottom value display Displays the set value. (The set value Displays the accumulated value. (The Displays the peak value. Displays the bottom value. of OUT2 cannot be displayed.) accumulated value of OUT2 cannot be displayed.) Line name display Fluid temperature display Displays the line name. (Up to 6 Displays the fluid temperature. alphanumeric characters can be input.) (When the temperature sensor type is selected.) OFF Displays nothing. The above are examples of integrated displays. (Same as remote monitor unit) Power saving mode The display can be turned off to reduce the power consumption. In power saving mode, decimal points blink on the main screen. If any button is pressed during power saving mode, the display is recovered for 3 seconds to check the flow, etc. Setting of secret code Users can select whether a secret code must be entered to release key lock. t the time of shipment from the factory, it is set such that the secret code is not required. 354 Peak/ottom value indication The maximum (minimum) flow is detected and updated from when the power supply is turned on. In peak (bottom) value indication mode, this maximum (minimum) flow is displayed. Keylock function Prevents operation errors such as accidentally changing setting values.

3 -color/2-screen display

3 -color/2-screen display -color display -color/-screen display Main screen Sub screen Note ) Main screen Sub screen Note ) ccumulated value New Digital Flow Switch for Water Instantaneous flow rate Set value Note ) Peak/ottom

More information

3-colour / 2-screen display

3-colour / 2-screen display 3-colour display RoHS New Digital Flow Switch for Water IP65 3-colour / 2-screen display Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference) Digital Flow Switch for Deionized Water and Chemical Liquids PFD Series RoHS single controller can monitor the flow rate of different sensors. Body and New PF Tube Super PF Dust generation of particles/cc

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch (F)/(H) Series Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor unit: Stainless steel 630 Fitting parts: Stainless steel 304 The sensor unit

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Remote Type Pressure Sensors Pressure Sensor Controllers

Remote Type Pressure Sensors Pressure Sensor Controllers CT.EUS1-56B-UK Remote Type Pressure Sensors Pressure Sensor Controllers Compact Pressure Sensor for Pneumatics PSE53 Multi-channel Digital Pressure Sensor Controller PSE2 Compact Pressure Sensor for Pneumatics

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth! Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch

More information

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa 3-Screen Display High-Precision Digital Pressure Switch Air General Fluids 1.0 ISE70 ISE71 MPa/1.6 MPa 1.0 ISE70G ISE75G MPa/2.0 MPa 5.0 ISE76G ISE77G MPa/10 MPa It is possible to change the settings while

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

2-colour Display High Precision Digital Pressure Switch

2-colour Display High Precision Digital Pressure Switch High Precision, -colour Display Digital Pressure Switch -colour Display High Precision Digital Pressure Switch Series ZSE/ISE Features djustable vacuum, positive and compound pressure switch with display.

More information

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA CAT.ES- A for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA Three types of flow range. to l /min (PFD). to l /min (PFD). to l /min (PFD) Swept flow characteristics Tapered side seal

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 26-580 www.cmafh.com Digital Flow Switch for Deionized Water and Chemicals Series Body and New PFA Tube

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure High Precision, Series SE30/ISE30 How Order Option 1 Without lead wire Lead wire with connecr (Lead wire length: 2 m) L For positive pressure For vacuum/low pressure ISE30 01 SE30 01 25 M 25 M 01 R 1/8

More information

Low Differential Pressure Sensor ±1% F.S.

Low Differential Pressure Sensor ±1% F.S. CAT.ES100-49 A Low Differential Pressure Sensor Rated differential pressure range: 0 to 2 kpa Accuracy: ±1% F.S. LED display to confirm energization Series PSE550 Proof pressure: 65kPa Output: 1 to 5VDC

More information

Digital Flow Switch for Deionized Water and Chemicals

Digital Flow Switch for Deionized Water and Chemicals Digital Flow Switch for Deionized Water and Chemicals Series PFD A single controller can monitor the flow rate of different sensors. Body and New PFA Tube Super PFA Three types of flow range 0. to l/min

More information

l/min (Comparison under Nozzle diameter: ø0.3, Vacuum pressure: 60 kpa) New

l/min (Comparison under Nozzle diameter: ø0.3, Vacuum pressure: 60 kpa) New Flow Sensor Suction check of very small workpieces This flow sensor enables precise suction. Pressure sensor Flow sensor 60 58 kpa Before suction During suction Before suction Pressure difference Small

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics The ZSE3/E3 series is to be discontinued. We recommend you consider using the Z/E10 series or the

More information

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa Series 0-PSE50 Remote type pressure sensor How to Order Clean series 0 PSE5 0 M5 Pressure sensing range Option 0 2 High pressure [0 to MPa] Vacuum [0 to 0 kpa] Low pressure [0 to 0 kpa] Compound pressure

More information

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids Leakage rating: 1 X 10-9 atm cc/s With Backlight Digital Pressure Switch Series ZSE6B (For vacuum) ISE6B (For positive pressure) Sensor and fitting section are electron beam welded. 2 kinds of metal gasket

More information

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES 76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor

More information

(Actual size) 2 switches 10 switches. Push Adjust to the set-value by the or button.

(Actual size) 2 switches 10 switches. Push Adjust to the set-value by the or button. Digital Pressure Switch RoHS compliant Low profile 9.8 mm (Actual size) 13.5 mm 53.4 mm Vertical mounting space reduced to approx.! 1 2 Reduced in depth! 26.1 mm Can copy to up to 1 switches simultaneously.

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector Non-rotating Type High Precision Scale Cylinder Series CEP1 ø12, ø How to Order CEP1 12 0 F9N L F High precision scale cylinder Mounting bracket Direct mounting front tapped type Foot type Front flange

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

2-Colour Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2m) L For positive pressure For vacuum/low

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series High-Precision Digital Pressure Switch ZSE40 /ISE40 Series Set pressure range 0.00 to.000 Pa For positive pressure How to Order For Positive Pressure ISE40 0 22 SDPC For Vacuum/Compound Pressure ZSE40

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter Clean Air Module Series Digital flow switch Regulator ON/OFF valve Restrictor Filter Modularizes clean equipment (Reduced piping man-hours/space-saving). Easily obtains clean air. Built-in one-touch fitting

More information

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting Controller Series PSE100 How to Order PSE10 Output specifications 0 NPN output 1 PNP output Mounting A B Option Without cover C With cover Panel mounting Wall mounting, DIN rail Controller Specifications

More information

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Pressure measurements can easily be taken any time, anywhere. RoHS Compact and lightweight Portable type with a lightweight of only about 00 g (unit 50 g, battery 50 g) can also be held

More information

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in) Compact acuum Unit Ejector/acuum Pump System Quick response Compact/ Lightweight Response time of the : 5 ms acuum response time: 28 ms (Shortened by 25%; Comparison with other SMC products) Conditions:

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

Compact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm.

Compact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm. Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:

More information

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm. SERIES LED Display Anti-corrosive Digital ure Sensor DP3 ure Measurement of Corrosive Gases and Liquids Possible! Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless

More information

Series PSE560 Pressure Sensor For General Fluids... 90

Series PSE560 Pressure Sensor For General Fluids... 90 Table of Contents Pressure Switch Selection Guide... Electronic Pressure Switch... Mechanical Pressure... Pressure Switch Application Example... Series SE/ISE High Precision, 2-color Display Digital Pressure

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:

More information

Speed Controller with Indicator

Speed Controller with Indicator Speed Controller with Indicator The numerical indication of flow rate knob rotations reduces flow setting time and setting errors! Elbow Universal Brass Electroless nickel plated RoHS Stainless steel 1

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits SERIES LED Display Digital Pressure Sensor Complete Functionality from a Wide Model Line-up Marked Conforming to EMC Directive High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits SERIES LED Display Digital Pressure Sensor PE DP-M DP-Y DP3 High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response time at a high resolution of 1/1,000. It enables highly accurate

More information

±0.18 F (±0.1 C) 88 lb (40 kg) 104 lb (47 kg) 152 lb (69 kg) 161 lb (73 kg) With heating function. Convenient functions

±0.18 F (±0.1 C) 88 lb (40 kg) 104 lb (47 kg) 152 lb (69 kg) 161 lb (73 kg) With heating function. Convenient functions Circulating Fluid Temperature Controller Thermo-chiller Lightweight/Compact Temperature stability Compact Type ±.18 F (±.1 C) HRS5 New New HRS6 (UL Standards) ( HRS3/6: Pending) RoHS HRS12/18/24 New HRS3

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector

More information

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42) Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil Ionizer / with surface potential sensor Series IZS0 How to Order 00 0 00 00 Ionizer IZ S 0 0 Bar length Bar length 00 mm 0 mm mm 00 mm 00 mm Ionizer Made to Order Bar type Size Electrode needle material

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

2 Window comparator mode. Hysteresis Hysteresis

2 Window comparator mode. Hysteresis Hysteresis SERIES High-performance Digital Pressure Sensor Digital Automatic sensitivity setting With analog output Complete functionality! Selection from a wide lineup DP3 * UL 61010C-1 compatible, Passed the UL

More information

Digital Flow Switch (Integrated display type)

Digital Flow Switch (Integrated display type) PRODUCT NAME Digital Flow Switch (Integrated display type) MODEL / Series / Product Number PF2A7##H Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model Suction Filter with Case FH99 Series RoHS Compact and lightweight The compact and lightweight design employs an aluminum casted housing. Prevents pump cavitation The inlet size is larger than the outlet

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4 Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42) Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

240 g. 290 g. Compact and lightweight. Electric Actuators. Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type

240 g. 290 g. Compact and lightweight. Electric Actuators. Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type Electric ctuators Series LEPY/LEPS Miniature Rod Type/Miniature Slide Table Type Step Motor (Servo/2 VDC) and lightweight Rod Type Series LEPY Weight 2 g LEPY6-2 RoHS Maximum pushing force: N Positioning

More information

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

Rectangular Multi-connector. No. of Connecting Tubes: 10, 20. Plate. Plug connector Socket connector PAT.PEND

Rectangular Multi-connector. No. of Connecting Tubes: 10, 20. Plate. Plug connector Socket connector PAT.PEND Rectangular Multi-connector KDM Series No. of Connecting Tubes: 1, 2 RoHS Multi-connector is effective in saving labor for separate transportation of the panel and the machine, and for exchanging units

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

4 Note 1) Value for communications type. (PROFIBUS DP)

4 Note 1) Value for communications type. (PROFIBUS DP) Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including

More information

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40,

More information

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications Manifold Regulator Modular Type /3000 Series modular type that can be freely mounted on a manifold station. Optimal for central pressure control. Easily set up using the new knob. lso has a One-touch lock

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor "Cube" Type Differential Pressure Sensor with LED Display Offers High Precision Sensing 31 (1.) x 3 (1.18) x 3 (1.18) mm compact-cube style saves mounting space Easy-to-read

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Digital Flow Switch (Integrated display type)

Digital Flow Switch (Integrated display type) PRODUCT NAME Digital Flow Switch (Integrated display type) MODEL / Series / Product Number PF2A7## Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts

More information