3-colour / 2-screen display

Size: px
Start display at page:

Download "3-colour / 2-screen display"

Transcription

1 3-colour display RoHS New Digital Flow Switch for Water IP65 3-colour / 2-screen display Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated value Peak/Bottom value Instantaneous flow rate Note ) Line name Fluid temperature Note ) Main screen shows the instantaneous flow rate only. Note 2) Fluid temperature can be displayed only when the digital flow switch with a temperature sensor is selected. Note 3) Sub screen can be turned off. Note 2) Integrated flow adjustment valve and temperature sensor New Flow adjustment valve dditional remote type New dditional PVC piping type New Remote sensor unit Temperature sensor Series Remote type 3-colour display Digital flow monitor pplicable fluid: Deionized water, chemical, etc. Flow rate range: to l/min Integrated type and remote type added to series. CT.EUS-8B-UK

2 Digital Flow Switch for Water 4% 4% smaller than existing product Reducing piping space Shortened 74-3 PF2W74-3 (Existing product) 3 5 Straight piping length 42 PF2W74 74 Existing product requires a straight piping length at least 8 times the piping diameter. Temperature sensor Display range: to C (Temperature sensor alone) Minimum setting unit: C nalogue output: Current output/voltage output Flow adjustment valve Space saving and reduced piping labour Temperature display Temperature sensor Fluid temperature: to 9 C Ethylene glycol aqueous solution can be used Example) Flow control of the circulating fluid in a chiller Customer s machine Rotatable display Display can be rotated in increments of 45 to suit the installation conditions. Easy operation, improved visibility. Counterclockwise 9 Clockwise turn OUT IN OUT (No rotation) Non-grease Mounting OUT IN 8 turn 9 turn IN Bracket mounting Direct mounting Panel mounting Front protective cover Panel mount adapter Features Tapping screw (4 pcs.) Waterproof seal (accessory) Panel Mounting screw (M3 x 8 L) (accessory)

3 Series sensor Monitor 3/8 How to Order 2 to 6 3/8, /2 5 to 4 /2, 3/4 Specifications (Integrated Display) 2 to 3/4, Specifications (Remote Sensor Unit) 3 Flow-rate Characteristics (Pressure Loss) 4 PVC piping Integrated type Deionized water Remote sensor to 25 Example of Internal Circuit and Wiring 5, 6 Made to Order 6 Chemical Monitor Description/ Wetted Parts Construction 7 Dimensions 8 3-colour display Digital flow monitor can copy to up to switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. setting labour Minimising risk of mistakes in setting 3-Colour Display Digital Flow Switch for PVC Piping Copy How to Order Reducing Specifications (Integrated Display) 2 Master sensor (source of copy) Slave side unit (copy destination) 2 units units Specifications (Remote Sensor Unit) 3 Description/ Wetted Parts Constructions 4 Dimensions 5 Indicator Visually check status of sensor via indicator. Reducing wiring labour by connector e-con connector No tools and peeling required Blinking green/fast Flow rate: Low Blinking green/slow Rated flow or less OFF Rated flow or more Red ON PVC piping type How to Order 6 Specifications 7 Example of Internal Circuit and Wiring 8, M8 connector Flow rate: High 3-Colour Display Digital Flow Monitor for Water 3 9 Description (Remote Monitor Unit) 9 Dimensions 2 Power supply/output connection lead wire Ethylene glycol aqueous solution Remote.5 to 4 Water 3-Colour Display Digital Flow Switch for PVC Piping Integrated 3-Colour Display Digital Flow Switch for Water 3 Flow adjustment valve/temperature sensor Rated pplicable Port size Flow Flow adjustment flow range Temperature fluid adjustment valve + Tempera- Rc, NPT, G None sensor (l/min) valve ture sensor Type 3-Colour Display Digital Flow Switch for Water INDEX 3-Colour Display Digital Flow Monitor for Water Variations l/min added Wetted Parts Pipe CPVC (Heat resistant PVC) Body PPS Seal FKM Details 2 Features 2 Details Measured flow rate

4 3-colour display Digital Flow Switch for Water Series How to Order RoHS Remote sensor unit Integrated display Symbol S T T M Type Remote sensor unit Integrated display Rated flow range (Flow range) Symbol Rated flow range.5 to 4 l/min 2 to 6 l/min 5 to 4 l/min to l/min Flow adjustment valve With/without flow Rated flow rate adjustment valve None Yes l/min type is not available with flow adjustment valve. Note ) External input: The accumulated value, peak value, and bottom value can be reset. Note 2) For units with temperature sensor, OUT2 can be set as either temperature output or flow rate output. Setting when shipped is for temperature output. Options/Part No. Remote sensor unit/ Instantaneous ccumulated Unit printed on label Symbol Temperature flow rate flow l/min l C G gal/min gal C Remote sensor unit Output specification/temperature sensor F gal/min gal F OUT OUT2 J l/min l F Symbol Temperature sensor Flow rate Temperature Note) G, F, J: Made to Order nalogue to 5 V Reference: [l/min].2642 [gal/min] None 2 nalogue 4 to 2 m [gal/min] [l/min] F = 9/5 C + 32 T nalogue to 5 V nalogue to 5 V With temperature sensor Symbol Port size 3/8 /2 3/4 Thread type Rc N NPT F G Integrated display Output specification/ Temperature sensor Temperature sensor OUT OUT2 Symbol Flow rate Flow rate Temperature B C D E F G H nalogue to 5 V nalogue 4 to 2 m nalogue to 5 V nalogue 4 to 2 m External input Note ) External input Note ) T BT CT () () (nalogue to 5 V) Note 2) Note 2) Note 2) nalogue to 5 V DT (nalogue 4 to 2 m) Note 2) nalogue 4 to 2 m ET (nalogue to 5 V) Note 2) nalogue to 5 V FT (nalogue 4 to 2 m) Note 2) nalogue 4 to 2 m Port size Rated flow range None With temperature sensor When optional parts are required separately, use the following part numbers to place an order. Description Part no. Qty. Note Bracket Note) ZS-4-K ZS-4-L ZS-4-M For 74/72/54/52 For 74/54 For 7/5 With 4 tapping screws (3 x 8) With 4 tapping screws (3 x 8) With 4 tapping screws (4 x ) Lead wire with M8 connector ZS-4- Lead wire length (3 m) Note) For units with flow adjustment valve, 2 brackets are required. Bracket (Option) None Bracket R Made to Order X9 Seal material EPDM (Refer to page 6.) Calibration certificate (Only flow sensor) None With calibration certificate The certificate is written in both English and Japanese. Integrated display type with temperature sensor can only display flow rate. Integrated display/unit specification Symbol Instantaneous ccumulated flow rate flow Temperature M G F J l/min gal/min gal/min l/min l gal gal l C C F F Note) G, F, J: Made to Order Reference: [l/min].2642 [gal/min] [gal/min] [l/min] F = 9/5 C + 32 Lead wire N With lead wire with M8 Without lead wire connector with M8 (3 m) connector

5 3-colour display Digital Flow Switch for Water Series Specifications (Integrated Display) Model pplicable fluid Detection method Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex Rated flow range.5 to 4 l/min 2 to 6 l/min 5 to 4 l/min to l/min Display flow range.35 to 5.5 l/min.7 to 22. l/min 3.5 to 55. l/min 7 to 4 l/min (Flow under.35 l/min is displayed as. ) (Flow under.7 l/min is displayed as. ) (Flow under 3.5 l/min is displayed as. ) (Flow under 7 l/min is displayed as ) Set flow range.35 to 5.5 l/min.7 to 22. l/min 3.5 to 55. l/min 7 to 4 l/min Minimum setting unit. l/min. l/min l/min Conversion of accumulated pulse (Pulse width: 5 ms).5 l/pulse. l/pulse.5 l/pulse l/pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss ccumulated flow range Note 4) to 9 C (with no freezing and condensation) Instantaneous flow rate: l/min, ccumulated flow: l Display value: ±3% F.S. nalogue output: ±3% F.S. ±2% F.S. Note 2) ±5% F.S. (25 C reference) to MPa.5 MPa 45 kpa at the maximum flow (without flow adjustment valve) l l By. l By.5 l By l Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note 2), 5) Output protection Output Flow rate mode Temperature Response time Note 6) nalogue output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 7) Insulation resistance Standards and regulations Wetted parts material Note 8) Piping port size Weight Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 4. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Note 2) When.5 s is selected for the response time of the switch output, the repeatability becomes ±3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to page 3. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorise it. (Every 2 or 5 minutes) When 5 minutes memorising is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 24 hour energizing). Calculate the lifetime based on your operating conditions before using the memorising function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 6) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analogue output by the temperature sensor.) Note 7) When the temperature sensor is used, it will be 25 VC. Note 8) Refer to Wetted Parts Construction on page 7 for details. Temperature Sensor Specifications Rated temperature range Setting/Display temperature range Minimum setting unit Display unit Display accuracy nalogue output accuracy Response time mbient temperature characteristics Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9 C. Note 2) The response time is for the temperature sensor alone. or open collector output 8 m 28 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current).5s / s / 2s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. Select from hysteresis mode or window comparator mode..5s / s / 2s (linked with the switch output) Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer 2-screen display (Main screen: 4-digit, 7-segment, 2-colour, Red/Green Sub screen: 6-digit, -segment, White) Display values updated 5 times per second Output, Output 2: Orange 2 to 24 VDC ±% 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 MΩ or more (5 VDC mega metre) between whole live part and enclosure CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 2 g 285 g 3 g 385 g to C Note ) to C C C ±2 C ±3% F.S. 7 s Note 2) ±5% F.S. 3/8, /2 26 g 335 g 36 g 435 g +85 g /2, 3/4 4 g 53 g 6 g 73 g The output related to the temperature sensor is OUT2 only. Flow rate detecting circuit Temperature detecting circuit 3/4, 72 g 86 g OUT Switch output OUT2 Switch output nalogue output The OUT2 can be selected from the output for temperature or flow rate by button operation. Black OUT White OUT2 2 3-Colour Display Digital Flow Switch for Water 3-Colour Display Digital Flow Switch for PVC Piping 3-Colour Display Digital Flow Monitor for Water 3 Details

6 Series Specifications (Remote Sensor Unit) Model pplicable fluid Detection method Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex Rated flow range.5 to 4 l/min 2 to 6 l/min 5 to 4 l/min to l/min Fluid temperature ccuracy Repeatability Temperature characteristics to 9 C (with no freezing and condensation) ±3% F.S. ±2% F.S. ±5% F.S. (25 C reference) Operating pressure range Proof pressure Note 2) Pressure loss nalogue output Indicator light Power supply voltage Current consumption Note 2) Response time Note 3) Voltage output Current output Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 4) Insulation resistance Standards and regulations Wetted parts material Note 5) Piping port size Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector Weight Refer to page 7 for monitor specifications. to MPa Note 2).5 MPa 45 kpa or less at the maximum flow (without flow adjustment valve) s Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC For power supply status, flow rate indicator (Blinking speed changes in response to flow rate), and other error indicator 2 to 24 VDC ±% 3 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 MΩ or more (5 VDC mega metre) between whole live part and enclosure CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 95 g 27 g 295 g 37 g 3/8, /2 245 g 32 g 345 g 45 g +85 g /2, 3/4 395 g 55 g 595 g 75 g 3/4, 75 g 84 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 4. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Note 2) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analogue output by the temperature sensor.) Note 4) When the temperature sensor is used, it will be 25 VC. Note 5) Refer to Wetted Parts Construction on page 7 for details. nalogue Output Temperature Sensor Specifications Rated temperature range to C Note ) nalogue output ±3% F.S. accuracy Response time 7 s Note 2) mbient temperature ±5% F.S. characteristics Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9 C. Note 2) The response time is for the temperature sensor alone. Flow rate/nalogue output Voltage output Current output B C V.5 V (.4 V) 5 V Output 4 m 6 m (5.6 m) 2 m C Values in parentheses are for the 7/5. Model 74/54 72/52 74/54 7/5 Rated flow [l/min] Minimum Maximum Minimum rated flow Operating Pressure and Proof Pressure B Maximum Flow rate rated flow Fluid temperature/nalogue output 7/5 Voltage output Current output Voltage output Current output.6 V 2.4 m C 5 V 2 m B V 4 m D 5.4 V 2.6 m Output D C B C C C C Fluid temperature 3 74/72/74/54/52/54 Pressure [MPa] Proof pressure [MPa].8.6 Operating pressure [MPa] Fluid temperature [ C] 74S/72S/74S/54S/52S/54S Pressure [MPa] Proof pressure [MPa].8.6 Operating pressure.4 [MPa] Fluid temperature [ C] 7/5 Pressure [MPa] Proof pressure [MPa] Operating pressure [MPa] Fluid temperature [ C]

7 3-colour display Digital Flow Switch for Water Series Flow-rate Characteristics (Pressure Loss: Without Flow djustment Valve) 74/54 Pressure loss [MPa] Pressure loss [MPa] /54 Flow rate [l/min] /54 ccuracy [% F.S.] 74/54 ccuracy [% F.S.] Flow rate [l/min] Pressure:.3 MPa Piping diameter: ø2 ± ±9 ±8 ±7 ±6 ±5 74/54-3 (at 4 l/min) ±4 ±3 ±2 ± ± Straight piping length [cm] ± ±9 ±8 ±7 ±6 ±5 74/54-4 (at 4 l/min) ±4 ±3 ±2 74/54-6 (at 4 l/min) ± ± Straight piping length [cm] Pressure loss [MPa] Flow rate [l/min] Straight Piping Length and ccuracy (Reference Value) Straight piping length 72/52 7/5 Pressure loss [MPa] The smaller the piping size, the more the product is affected by the straight piping length. Fluid pressure has almost no affect. Low flow rate lessens the effect of the straight piping length. Use a straight pipe that is 8 cm or longer in length to satisfy the ±3% F.S. specification. ( cm or longer for L/min type) 72/52 ccuracy [% F.S.] Pressure:.3 MPa Piping diameter: ø2 Pressure:.3 MPa Pressure:.3 MPa Piping diameter: 25 (Port size ) Piping diameter: ø6 7/5 2 (Port size 6) ccuracy [% F.S.] ± ±9 ±8 ±7 ±6 ±5 ±4 ±3 ±2 ± ± Flow rate [l/min] 72/52-3 (at 6 l/min) 72/52-4 (at 6 l/min) 72/52-3 (at 8 l/min) Straight piping length [cm] ±6 ±4 ±2 7/5-6 (at l/min) 7/5- ± (at l/min) 7/5-6 ±8 (at 5 l/min) ±6 ±4 ±2 7/5- (at 5 l/min) ± Straight piping length [cm] No data for 4 cm, or for under 5 cm, as these cannot be used due to piping dimensions. Flow-rate Characteristics of Flow djustment Valve 74S/54S Flow rate [l/min] 72S/52S Flow rate [l/min] 74S/54S Measurable Range for Ethylene Glycol queous Solution (Reference Value) queous solution concentration [%] (Weight) P =.4 MPa P =.3 MPa P =.2 MPa P =. MPa Number of rotations [rotations] P: Pressure differential between the front and the rear of product Flow rate [l/min] P =.5 MPa P =.4 MPa P =.2 MPa P =. MPa Number of rotations [rotations] P: Pressure differential between the front and the rear of product P =.3 MPa P =.5 MPa P =.4 MPa P =.5 MPa P =.3 MPa P =.2 MPa P =. MPa Number of rotations [rotations] P: Pressure differential between the front and the rear of product Measurable within this range queous solution temperature [ C] 4 3-Colour Display Digital Flow Switch for Water 3-Colour Display Digital Flow Switch for PVC Piping 3-Colour Display Digital Flow Monitor for Water 3 Details

8 Series Example of Internal Circuit and Wiring/Series 7 (Integrated Display) 2 Output type 7 - -(T)- 2 Output type 7 - -B(T)- Black OUT White OUT2 2 to 24 VDC Black OUT White OUT2 2 to 24 VDC + nalogue output type 7 - -C(T)- + nalogue output type 7 - -D(T)- + nalogue output type 7 - -E(T)- + nalogue output type 7 - -F(T)- Black OUT White nalogue output 2 to 24 VDC Black OUT White nalogue output 2 to 24 VDC + External input type 7 - -G- + External input type 7 - -H- Black OUT White External input 2 to 24 VDC Black OUT White External input 2 to 24 VDC Example of wiring for accumulated pulse output 2 Output type 7 - -(T)- + nalogue output type 7 - -C(T)- /7 - -D(T)- + External input type 7 - -G- 2 Output type 7 - -B(T)- + nalogue output type 7 - -E(T)- /7 - -F(T)- + External input type 7 - -H- Black OUT White OUT2 (7 (T) only) V or 5 ms 5 ms Black OUT White OUT2 (7 B(T) only) V or 5 ms 5 ms When accumulated pulse output is selected, indicator light turns off. 5

9 3-colour display Digital Flow Switch for Water Series Example of Internal Circuit and Wiring/Series 5 (Remote Sensor Unit) nalogue 2 Output type Black OUT nalogue output (Flow rate) White OUT2 nalogue output (Temperature) OUT2 (white wire) only for units with temperature sensor 2 to 24 VDC Made to Order Seal material for wetted parts changed to EPDM 5 7 Refer to How to Order, page for details. Note) Not compatible with units with flow adjustment valve. Please special-order separately. X9 X9 Seal material EPDM Please consult SMC for detailed dimensions, specifications and delivery. Symbol -X9 Details 3-Colour Display Digital Flow Monitor for Water 3 3-Colour Display Digital Flow Switch for PVC Piping 3-Colour Display Digital Flow Switch for Water 6

10 Series Description Main unit Integrated display (With temperature sensor and flow adjustment valve) Remote sensor unit (With temperature sensor and flow adjustment valve) Flow adjustment knob Lock ring FLOW indicator Connector Lead wire with M8 connector (Option) Piping port (OUT side) Flow adjustment valve (When the unit with flow adjustment valve is selected) POWER indicator Piping port (IN side) Bracket (Option) Temperature sensor (When the unit with temperature sensor is selected) Display Output display (Indicator light) Sub screen Main screen (2-colour display) Unit display UP button SET button DOWN button Wetted Parts Construction Description Connector Lead wire with M8 connector Piping port Bracket Temperature sensor Flow adjustment valve Flow adjustment knob Lock ring POWER indicator FLOW indicator Connects the lead wire. Supplies power to the product and ensures output. Connects to the piping. Inlet piping goes to the IN side, and outlet piping goes to the OUT side. Mounting bracket for installation of the product Detects the fluid temperature. Orifice mechanism to adjust the flow rate. djusts the flow rate. Fixes the flow adjustment knob in place. Indicates the power supply status, indicates product specifications and indicates errors. Blinks at a cycle proportional to the flow rate or indicates errors. Turns off when below rated flow. Description Main screen (2-colour display) Displays the flow, status of setting mode, and error code. Displays the accumulated flow, set value, peak/bottom value, fluid temperature, and line name. Sub screen In the setting mode, the set status is displayed. (Refer to page 2 for details.) Output display (Indicator light) Displays the output status of OUT and OUT2. When ON: Orange light turns on. Unit display Displays the unit selected. UP button Selects the mode and the display shown on the sub screen, and increases the ON/OFF set values. SET button Press this button to change the mode and to set a set value. DOWN button Selects the mode and the display shown on the sub screen, and decreases the ON/OFF set values. 7 o i q r w t w e y w u!2! w!3! w Component Parts No. Description ttachment 2 Seal 3 Body 4 Sensor Temperature sensor Temperature sensor body Flow adjustment valve body Flow adjustment valve cover Flow adjustment valve shaft Shaft support O-ring Cap seal Y seal Material SCS3 FKM PPS PPS Stainless steel 34 Stainless steel 34 PPS PPS Stainless steel 34 PPS FKM FKM FKM Note Stainless steel 34 equivalent With brazing JIS Z 326: Bg-7, ISO 3677: B-g56CuZnSn-62/65 ( )

11 3-colour display Digital Flow Switch for Water Series Dimensions 74/72/74/7 Integrated display Connector pin number Example /52/54/5 Remote sensor unit 2 Pin no Pin name DC (+) OUT2 DC ( ) OUT N IN B N 3 K (35.5) H 5 S K J L 42 T U L H 42 (35.5) 4 x P 4 x WX 4 x P OUT V W G Z Y D.4 E F 2 x piping port 3-Colour Display Digital Flow Switch for Water 3-Colour Display Digital Flow Switch for PVC Piping Model 74/54 72/52 74/54 7/5 Port size (Rc, NPT, G) 3/8 3/8, /2 /2, 3/4 3/4, B D DD IN B 3 E F S G J H T U J K x WX L N OUT V W P ø2.7 depth 4 ø2.7 depth 2 ø2.7 depth 2 ø3.5 depth 4 G S Y DD E F 2 x piping port Z Bracket dimensions T U V W WX Y (mm) Z Colour Display Digital Flow Monitor for Water 3 Details

12 Series Dimensions 74/72/74/7- - T Integrated display: With temperature sensor 54/52/54/5- - T Remote sensor unit: With temperature sensor (mm) Model 74/54- - T 72/52- - T 74/54- - T 7/5- - T S/72S/74S Integrated display: With flow adjustment valve 54S/52S/54S Remote sensor unit: With flow adjustment valve K L 4 x P K L 4 x P Q Q B B N N F F S D T S D T (mm) 9 Model 74S/54S 72S/52S 74S/54S B 63.6 (Max. 68.6) 63.6 (Max. 68.6) (Max. 8) D F K L N P ø2.7 depth ø2.7 depth ø2.7 depth Q ø9 ø9 ø28 Q number of rotations Bracket dimensions S T

13 3-colour display Digital Flow Switch for Water Series Dimensions 74S/72S/74S- - T Integrated display: With temperature sensor and flow adjustment valve K 54S/52S/54S- - T Remote sensor unit: With temperature sensor and flow adjustment valve K 3-Colour Display Digital Flow Switch for Water S D (mm) S D 3-Colour Display Digital Flow Switch for PVC Piping Model D K S 74S/54S- - T 72S/52S- - T 74S/54S- - T ø (32.8) ZS-4- Lead wire with M8 connector Pin no. Pin name Wire colour DC (+) OUT2 DC ( ) OUT Brown White Blue Black ø4 (3) (45) (5) (Black) 4 (Blue) 3 M8 2 (White) (Brown) Note) 4-wire type lead wire with M8 connector used for the series. Lead Wire Specifications Conductor Nominal cross section O.D. Material Insulator O.D. Colour Sheath Material Finished O.D. WG23 pprox..7 mm Heat resistant PVC pprox.. mm Brown, White, Black, Blue Heat and oil resistant PVC ø4 3-Colour Display Digital Flow Monitor for Water 3 Details

14 Remote sensor unit Integrated display colour display Digital Flow Switch for PVC Piping Series Remote sensor unit/output specification Symbol OUT nalogue to 5 V 2 nalogue 4 to 2 m 5 U 25 7 U 25 M Type Remote sensor unit Integrated display How to Order Remote sensor unit/ Unit printed on label Symbol Instantaneous ccumulated flow rate flow Temperature l/min l C G gal/min gal C F gal/min gal F J l/min l F Note) G, F, J: Made to Order Reference: [l/min].2642 [gal/min] [gal/min] [l/min] F = 9/5 C + 32 Bracket (Option) None Bracket Calibration certificate (Only flow sensor) RoHS None With calibration certificate The certificate is written in both English and Japanese. Rated flow range (Flow range) Symbol Rated flow range to l/min Connection type U PVC pipe PVC pipe O.D. Symbol Port size Integrated display/output specification Symbol OUT OUT2 B C D E F G H nalogue to 5 V nalogue 4 to 2 m nalogue to 5 V nalogue 4 to 2 m External input External input External input: The accumulated value, peak value, and bottom value can be reset. R Integrated display/unit specification Symbol Instantaneous ccumulated flow rate flow Temperature M l/min l C G gal/min gal C F gal/min gal F J l/min l F Note) G, F, J: Made to Order Reference: [l/min].2642 [gal/min] [gal/min] [l/min] F = 9/5 C + 32 Lead wire N With lead wire with M8 connector (3 m) Without lead wire with M8 connector Options/Part No. When optional parts are required separately, use the following part numbers to place an order. Description Part no. Qty. Note Bracket Lead wire with M8 connector ZS-4-M ZS-4- With 4 tapping screws (4 x ) Lead wire length (3 m)

15 3-colour display Digital Flow Switch for PVC Piping Series Specifications (Integrated Display) Model pplicable fluid Detection method Rated flow range Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss ccumulated flow range Note 4) Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note 2), 5) Output protection Output mode Flow rate Response time Note 6) nalogue output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Wetted parts material Note 7) Piping port size Without lead wire with connector Weight With lead wire with connector 7 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to l/min 7 to 4 l/min (Flow under 7 l/min is displayed as ) 7 to 4 l/min l/min l/pulse to 7 C (with no freezing and condensation) Instantaneous flow rate: l/min, ccumulated flow: l, Display values updated 5 times per second Display value: ±3% F.S. nalogue output: 3% F.S. ±2% F.S. Note 2) ±5% F.S. (25 C reference) to MPa MPa 45 kpa or less at the maximum flow l By l or open collector output 8 m 28 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current).5s / s / 2s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode..5s / s / 2s (linked with the switch output) Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer 2-screen display (Main screen: 4-digit, 7-segment, 2-colour, Red/Green Sub screen: 6-digit, -segment, White) Output, Output 2: Orange 2 to 24 VDC ±% 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 MΩ or more (5 VDC mega metre) between whole live part and enclosure CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 4. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 24. Note 2) When.5 s is selected for the response time of the switch output, the repeatability becomes ±3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to page 3. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorise it. (Every 2 or 5 minutes) When 5 minutes memorising is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 24 hour energizing). Calculate the lifetime based on your operating conditions before using the memorising function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. Note 6) The response time until the set value reaches 9% in relation to the step input. Note 7) Refer to Wetted Parts Construction on page 4 for details g 37 g Details 3-Colour Display Digital Flow Switch for Water 3-Colour Display Digital Flow Switch for PVC Piping 3-Colour Display Digital Flow Monitor for Water 3 2

16 Series Specifications (Remote Sensor Unit) Refer to page 7 for monitor specifications. Model pplicable fluid Detection method Rated flow range Fluid temperature ccuracy Repeatability Temperature characteristics Operating pressure range Note 2) Proof pressure Note 2) Pressure loss Response time Note 3) nalogue output Voltage output Current output Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Wetted parts material Note 4) Piping port size Without lead wire with connector Weight With lead wire with connector 5 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to l/min to 7 C (with no freezing and condensation) ±3% F.S. ±2% F.S. ±5% F.S. (25C reference) to MPa Note 2) MPa 45 kpa or less at the maximum flow s Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC For power supply status, flow rate indicator (Blinking speed changes in response to flow rate), and other error indicator 2 to 24 VDC ±% 3 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 MΩ or more (5 VDC mega metre) between whole live part and enclosure CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease g 355 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 4. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 24. Note 2) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. Note 4) Refer to Wetted Parts Construction on page 4 for details. nalogue Output Flow rate/nalogue output Voltage output Current output V 4 m B C.4 V 5 V 5.6 m 2 m Rated flow [l/min] Model Minimum Maximum 7/5 Flow-rate Characteristics (Pressure Loss) 7/5 Pressure loss [MPa] Flow rate [l/min] Output C B Minimum rated flow Maximum Flow rate rated flow Straight piping length Fluid pressure has almost no effect. To maintain ±3% F.S. in the specificatioins, use a straight pipe that is cm or longer in length. Operating Pressure 7/5 (for PVC Piping) Max. operating pressure [MPa] Fluid temperature [ C] Straight Piping Length and ccuracy (Reference Value) 7/5 ccuracy [% F.S.] ± ±8 ±6 ±4 ±2 Pressure:.3 MPa Piping diameter: 25 7/5-U25 (at l/min) ± Straight piping length [cm] 3 For measurable range for ethylene glycol aqueous solution (reference values), refer to page 4. For examples of internal circuit and wiring, refer to pages 5 to 6.

17 3-colour display Digital Flow Switch for PVC Piping Series Description Main unit Lead wire with M8 connector (Option) Connector Integrated display (PVC piping) Piping port (OUT side) Remote sensor unit (PVC piping) FLOW indicator POWER indicator 3-Colour Display Digital Flow Switch for Water Piping port (IN side) Display Output display (Indicator light) Sub screen Bracket (Option) Main screen (2-colour display) Unit display Wetted Parts Construction q t w e r w t Description Connector Connects the lead wire. Lead wire with M8 connector Supplies power to the product and ensures output. Piping port Connects to the piping. Inlet piping goes to the IN side, and outlet piping goes to the OUT side. Bracket Mounting bracket for installation of the product. POWER indicator Indicates the power supply status, indicates product specifications and indicates errors. Blinks at a cycle proportional to the flow rate or indicates errors. Turns off when FLOW indicator below rated flow. UP button Description Main screen (2-colour display)t Displays the flow, status of setting mode, and error code. SET button Sub screen Displays the accumulated flow, set value, peak/bottom value, fluid temperature, and line name. In the setting mode, the set status is displayed. (Refer to page 2 for details.) Output display (Indicator light) Displays the output status of OUT and OUT2. When ON: Orange light turns on. Unit display Displays the unit selected. UP button Selects the mode and the display shown on the sub screen, and increases the ON/OFF set values. SET button Press this button to change the mode and to set a set value. DOWN button Selects the mode and the display shown on the sub screen, and decreases the ON/OFF set values. DOWN button Component Parts No. Description PVC pipe 2 Seal 3 Body 4 Sensor Material CPVC FKM PPS PPS Note Replacement Parts No. Description Part no. Qty. PVC pipe ZS-4-U retaining plate (M5 x 8 with two hexagonal socket head cap screws) ZS-4-U25- Replacing the PVC pipe may cause accuracy to fluctuate by to 2%. 4 3-Colour Display Digital Flow Switch for PVC Piping 3-Colour Display Digital Flow Monitor for Water 3 Details

18 Series Dimensions 7-U25 Integrated display x 3.5 depth (35.5) Connector pin number Example IN OUT 3 4 Pin no Pin name DC (+) OUT2 DC ( ) OUT x x U25 Remote sensor unit IN OUT 62.6 ZS-4- Lead wire with M8 connector ø4 (Black) 4 2 (White) ø (32.8) Pin no. Pin name Wire colour DC (+) OUT2 DC ( ) OUT Brown White Blue Black 5 (Blue) 3 (Brown) (5) M8 (45) (3) Note) 4-wire type lead wire with M8 connector used for the series. Lead Wire Specifications Conductor Nominal cross section O.D. Material Insulator O.D. Colour Sheath Material Finished O.D. WG23 pprox..7 mm Heat resistant PVC pprox.. mm Brown, White, Black, Blue Heat and oil resistant PVC ø4

19 3 3-colour display Digital Flow Monitor for Water Series 3 3 Type Remote monitor unit For remote sensor units, select the analog output to 5 V type. pplicable sensors: 5 - -(T) Output specification Symbol OUT OUT2 B C D E F G H nalogue to 5 V nalogue 4 to 2 m nalogue to 5 V nalogue 4 to 2 m External input External input J K nalogue to 5 V nalogue 4 to 2 m nalogue to 5 V nalogue 4 to 2 m In combination with remote sensor unit with temperature sensor, only OUT2 can be set for temperature sensor output. Lead wire With power supply/output connection lead wire (2 m) Power supply/output connection lead wire ZS-4-W N Without power supply/output connection lead wire Lead wire is not connected, but shipped together. Options/Part No. How to Order Remote monitor unit/unit specification Symbol Instantaneous ccumulated flow rate flow Temperature M l/min l C G gal/min gal C F gal/min gal F J l/min l F Note) G, F, J: Made to Order Reference: [l/min].2642 [gal/min] [gal/min] [l/min] F = 9/5 C + 32 MVC Calibration certificate (Only flow monitor) None With calibration certificate The certificate is written in both English and Japanese. Option 2 None Sensor connector ( pc.) C Sensor connector (e-con) Connector is not connected, but shipped together. Option None Panel mount adapter T V Waterproof seal (accessory) Panel Panel mount adapter Mounting screw (M3 x 8 L) (accessory) Front protective cover + Panel mount adapter Front protective cover Panel mount adapter Mounting screw (M3 x 8 L) (accessory) Waterproof seal (accessory) When optional parts are required separately, use the following part numbers to place an order. Description Part no. Note Panel mount adapter Front protective cover + Panel mount adapter Front protective cover only Power supply/output connection lead wire Sensor connector (e-con) Lead wire with connector for copying ZS-26-B ZS-26-C ZS-26- ZS-4-W ZS-28-C-4 ZS-4-Y With waterproof seal and screws With waterproof seal and screws Separately order panel mount adapter, etc. Lead wire length (2 m) pc. Connect up to slave units Panel RoHS 6 3-Colour Display Digital Flow Switch for Water 3-Colour Display Digital Flow Switch for PVC Piping 3-Colour Display Digital Flow Monitor for Water 3 Details

20 Series 3 Specifications Model Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Display unit ccuracy Repeatability Temperature characteristics ccumulated flow range Note ) Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note 2) Output protection Output Flow rate mode Temperature Response time Note 3) nalogue output Voltage output Current output Hysteresis External input Input/output Display method Indicator light Power supply voltage Current consumption Connection Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Without power supply/output connection lead wire Weight With power supply/output connection lead wire.35 to 4.5 l/min (Flow under.35 l/min is displayed as. ).35 to 4.5 l/min. l/min.5 l/pulse 3.7 to 8. l/min 3.5 to 45. l/min. l/min. l/pulse.5 l/pulse Instantaneous flow rate: l/min, ccumulated flow: l Display value: ±.5% F.S. nalogue output: ±.5% F.S. ±.5% F.S. ±.5% F.S. (25C reference) l l 7 to 2 l/min l/min l/pulse By. l By.5 l By l or open collector output 8 m 28 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current) s / 2s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. Select from hysteresis mode or window comparator mode. s / 2s (linked with the switch output) Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer Input for copy mode 2-screen display (Main screen: 4-digit, 7-segment, 2-colour, Red/Green Sub screen: 6-digit, -segment, White), Display values updated 5 times per second Output, Output 2: Orange 2 to 24 VDC ±% 5 m or less Power supply output 5P connector, sensor connection 4P connector (e-con) IP4 (Only front face of the panel is IP65 when panel mount adapter and waterproof seal of optional parts are used.) to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 M or more (5 VDC mega metre) between whole live part and enclosure CE marking, UL (CS), RoHS 5 g g Note ) Cleared by turning off the power supply. It is possible to select the function to memorise it. (Every 2 or 5 minutes) When 5 minutes memorising is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 24 hour energizing). Calculate the lifetime based on your operating conditions before using the memorising function, and do not exceed it. Note 2) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analogue output by the temperature sensor.) Temperature Sensor Specifications.7 to 8. l/min (Flow under.7 l/min is displayed as. ) 3.5 to 45. l/min (Flow under 3.5 l/min is displayed as. ) 7 to 2 l/min (Flow under 7 l/min is displayed as ) Rated temperature range Setting/Display temperature range Minimum setting unit Display unit nalogue output accuracy Response time mbient temperature characteristics to C Note ) to C C C ±3% F.S. 7 s Note 2) ±5% F.S. Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9 C. Note 2) The response time is for the temperature sensor alone. nalogue Output Remote sensor unit The output related to the temperature sensor is OUT2 only. Remote monitor unit DC (+) Brown Flow rate to 5 V Black Temperature to 5 V White DC ( ) Blue OUT Switch output nalogue output OUT2 Switch output nalogue output The OUT2 can be selected from the output for temperature or flow rate by button operation. Black OUT White OUT2 Flow rate/nalogue output B C Voltage output V.5 V (.4 V) 5 V Current output 4 m 6 m (5.6 m) 2 m Values in parentheses are for the combination with the 5. Model Rated flow [l/min] Minimum Maximum Output C B Minimum rated flow Maximum rated flow Fluid temperature/nalogue output Voltage output Current output Voltage output Current output.6 V 2.4 m C 5 V 2 m B V 4 m D 5.4 V 2.6 m Be sure to use in combination with remote sensor units with temperature sensor. Flow rate Output D C B C C C C Fluid temperature

21 3-colour display Digital Flow Monitor for Water Series 3 Example of Internal Circuit and Wiring 2 Output type 3 Black OUT White OUT2 Grey COPY + nalogue output type 3C + nalogue output type 3D 2 to 24 VDC 2 Output type 3B Black OUT + nalogue output type 3E + nalogue output type 3F White OUT2 Grey COPY 2 to 24 VDC 3-Colour Display Digital Flow Switch for Water + External input type 3G Black OUT White nalogue output Grey COPY Black OUT White External input Grey COPY 2 to 24 VDC 2 to 24 VDC Black OUT White nalogue output Grey COPY + External input type 3H Black OUT White External input Grey COPY 2 to 24 VDC 2 to 24 VDC 3-Colour Display Digital Flow Switch for PVC Piping nalogue 2 Output type 3J/3K Black nalogue output White nalogue output Grey COPY 2 to 24 VDC Sensor input circuit to 5 V (Flow rate) Black DC ( ) Blue N.C./ to 5 V (Temperature) White DC (+) Brown r e w q Details 3-Colour Display Digital Flow Monitor for Water 3 8

22 Series 3 Example of Internal Circuit and Wiring Wiring example of accumulated pulse output 2 Output type 3 Black OUT + nalogue output type 3C/3D + External input type 3G 2 Output type 3B + nalogue output type 3E/3F + External input type 3H White OUT2 (3 only) V 5 ms 5 ms Black OUT White OUT2 (3B only) V or 5 ms 5 ms When accumulated pulse output is selected, indicator light turns off. or Description (Remote Monitor Unit) Main screen (2-colour display) Sensor connector Output display (Indicator light) Sub screen Unit display Power supply/ output connection lead wire Description Main screen (2-colour display) Displays the flow, status of setting mode, and error code. Sub screen Output display (Indicator light) Unit display UP button SET button DOWN button Displays the accumulated flow, set value, peak/bottom value, fluid temperature, and line name. In the setting mode, the set status is displayed. (Refer to page 2 for details.) Displays the output status of OUT and OUT2. When ON: Orange light turns on. Displays the unit selected. UP button SET button DOWN button Selects the mode and the display shown on the sub screen, and increases the ON/OFF set values. Press this button to change the mode and to set a set value. Selects the mode and the display shown on the sub screen, and decreases the ON/OFF set values. Sensor connector q w e r Power supply/output connection lead wire 2 9 Pin no. q w e r Terminal DC (+) N.C./IN DC ( ) INPUT Connector no Lead wire colour Brown White (Not used/temperature sensor to 5 V input) Blue Black (Flow rate sensor to 5 V input) When using the lead wire with M8 connector included with the 5 series Pin no Gray COPY White OUT2 Black OUT Lead Wire Specifications Conductor Insulator Nominal cross section O.D. Material O.D. Colour Sheath Material Finished O.D. WG26 pprox..5 mm Cross-linked vinyl pprox.. mm Brown, Blue, Black, White, Grey Oil and heat resistant vinyl ø3.5

23 3-colour display Digital Flow Monitor for Water Series 3 Dimensions NC/IN Sensor connector (4P) Power supply/ output connector (5P) Front protective cover + Panel mount adapter (2) 4. (7.5) Panel fitting dimmensions pplicable panel thickness:.5 to 8 mm (Without waterproof seal).5 to 6 mm (With waterproof seal) Front protective cover Waterproof seal Panel mount adapter Panel 48 or more 4 x R or less Details 55 or more 3-Colour Display Digital Flow Monitor for Water 3 3-Colour Display Digital Flow Switch for Water 3-Colour Display Digital Flow Switch for PVC Piping 2

24 Series Details Integrated Display (Series 7)/Remote Monitor Unit (Series 3) Output operation The output operation can be selected from the following: Output (hysteresis mode and window comparator mode) corresponding to instantaneous flow rate, Output corresponding to accumulated flow, ccumulated pulse output Note) t the time of shipment from the factory, it is set to hysteresis mode and normal output. When a temperature sensor is attached, the output to the temperature sensor is selectable only for OUT2. (Refer to How to Order for details.) Indication colour The indication colour can be selected for each output condition. The selection of the indication colour provides visual identification of abnormal values. (The indication colour depends on OUT setting.) ON: Green, OFF: Red ON: Red, OFF: Green lways: Red lways: Green Response time The response time can be selected depending on the application. ( second for default setting) bnormalities can be detected more quickly by setting the response time to.5 seconds. The effect of the pump fluctuation and flickering of the display can be reduced by setting the response time to 2 seconds. Note) The temperature sensor output is fixed to 7 seconds. Response time.5 seconds second 2 seconds Integrated display Series 7 pplicable model Remote monitor unit Series 3 Selection of display on sub screen The display on the sub screen in measuring mode can be set. External input function This function can be used when external input is available. The accumulated value, peak value, and bottom value can be reset by remote control. ccumulated flow external reset: This function resets the accumulated value to when an input signal is applied. In accumulated increment mode, the value will be zero when reset, and the accumulated value will increase from zero. In accumulated decrement mode, the value will be the set value when reset, and the accumulated value will decrease from the set value. When the accumulated value is memorised, every time the accumulated value external reset is activated, the memory element (EEPROM) will be accessed. Take into consideration the maximum number of times the memory element can be accessed, million times. The total of external input times and accumulated value memorising time interval should not exceed million times. Peak and bottom reset: Peak and bottom values are reset. Forced output function Output is turned ON/OFF compulsorily when starting the system or during maintenance. This enables confirmation of the wiring and prevents system errors due to unexpected output. For the analogue output type, the output will be 5 V or 2 m for ON and V or 4 m for OFF. lso, the increase or decrease of the flow and temperature will not change the on/off status of the output while the forced output function is activated. ccumulated value hold function ccumulated value can be saved on the unit even when the power supply is turned off. The accumulated value is memorised every 2 or 5 minutes during measurement, and continues from the last memorised value when the power supply is turned on again. The lifetime of the memory element is million access cycles. Take this into consideration before using this function. Sub screen Integrated display Remote monitor unit Set value display Displays the set value. (The set value of OUT2 cannot be displayed.) ccumulated value display Displays the accumulated value. (The accumulated value of OUT2 cannot be displayed.) Peak value display Displays the peak value. Bottom value display Displays the bottom value. Line name display Displays the line name. (Up to 6 alphanumeric characters can be input.) Fluid temperature display Displays the fluid temperature. (When the temperature sensor type is selected.) OFF Displays nothing. The above are examples of integrated displays. (Same as remote monitor unit) Power saving mode The display can be turned off to reduce the power consumption. In power saving mode, decimal points blink on the main screen. If any button is pressed during power saving mode, the display is recovered for 3 seconds to check the flow, etc. Setting of secret code Users can select whether a secret code must be entered to release key lock. t the time of shipment from the factory, it is set such that the secret code is not required. 2 Peak/Bottom value indication The maximum (minimum) flow is detected and updated from when the power supply is turned on. In peak (bottom) value indication mode, this maximum (minimum) flow is displayed. Keylock function Prevents operation errors such as accidentally changing setting values.

3 -color/2-screen display

3 -color/2-screen display -color display -color/-screen display Main screen Sub screen Note ) Main screen Sub screen Note ) ccumulated value New Digital Flow Switch for Water Instantaneous flow rate Set value Note ) Peak/ottom

More information

3 -color/2-screen display

3 -color/2-screen display 3-Color Display Digital Flow Switch for Water Series 3 -color/2-screen display RoHS IP65 Main screen Sub screen Note 3) Main screen Instantaneous flow rate Note ) Sub screen Set value Note 3) Instantaneous

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference) Digital Flow Switch for Deionized Water and Chemical Liquids PFD Series RoHS single controller can monitor the flow rate of different sensors. Body and New PF Tube Super PF Dust generation of particles/cc

More information

Remote Type Pressure Sensors Pressure Sensor Controllers

Remote Type Pressure Sensors Pressure Sensor Controllers CT.EUS1-56B-UK Remote Type Pressure Sensors Pressure Sensor Controllers Compact Pressure Sensor for Pneumatics PSE53 Multi-channel Digital Pressure Sensor Controller PSE2 Compact Pressure Sensor for Pneumatics

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch (F)/(H) Series Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor unit: Stainless steel 630 Fitting parts: Stainless steel 304 The sensor unit

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

2-colour Display High Precision Digital Pressure Switch

2-colour Display High Precision Digital Pressure Switch High Precision, -colour Display Digital Pressure Switch -colour Display High Precision Digital Pressure Switch Series ZSE/ISE Features djustable vacuum, positive and compound pressure switch with display.

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth! Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa 3-Screen Display High-Precision Digital Pressure Switch Air General Fluids 1.0 ISE70 ISE71 MPa/1.6 MPa 1.0 ISE70G ISE75G MPa/2.0 MPa 5.0 ISE76G ISE77G MPa/10 MPa It is possible to change the settings while

More information

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA CAT.ES- A for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA Three types of flow range. to l /min (PFD). to l /min (PFD). to l /min (PFD) Swept flow characteristics Tapered side seal

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure High Precision, Series SE30/ISE30 How Order Option 1 Without lead wire Lead wire with connecr (Lead wire length: 2 m) L For positive pressure For vacuum/low pressure ISE30 01 SE30 01 25 M 25 M 01 R 1/8

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 26-580 www.cmafh.com Digital Flow Switch for Deionized Water and Chemicals Series Body and New PFA Tube

More information

Low Differential Pressure Sensor ±1% F.S.

Low Differential Pressure Sensor ±1% F.S. CAT.ES100-49 A Low Differential Pressure Sensor Rated differential pressure range: 0 to 2 kpa Accuracy: ±1% F.S. LED display to confirm energization Series PSE550 Proof pressure: 65kPa Output: 1 to 5VDC

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Digital Flow Switch for Deionized Water and Chemicals

Digital Flow Switch for Deionized Water and Chemicals Digital Flow Switch for Deionized Water and Chemicals Series PFD A single controller can monitor the flow rate of different sensors. Body and New PFA Tube Super PFA Three types of flow range 0. to l/min

More information

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa Series 0-PSE50 Remote type pressure sensor How to Order Clean series 0 PSE5 0 M5 Pressure sensing range Option 0 2 High pressure [0 to MPa] Vacuum [0 to 0 kpa] Low pressure [0 to 0 kpa] Compound pressure

More information

l/min (Comparison under Nozzle diameter: ø0.3, Vacuum pressure: 60 kpa) New

l/min (Comparison under Nozzle diameter: ø0.3, Vacuum pressure: 60 kpa) New Flow Sensor Suction check of very small workpieces This flow sensor enables precise suction. Pressure sensor Flow sensor 60 58 kpa Before suction During suction Before suction Pressure difference Small

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

(Actual size) 2 switches 10 switches. Push Adjust to the set-value by the or button.

(Actual size) 2 switches 10 switches. Push Adjust to the set-value by the or button. Digital Pressure Switch RoHS compliant Low profile 9.8 mm (Actual size) 13.5 mm 53.4 mm Vertical mounting space reduced to approx.! 1 2 Reduced in depth! 26.1 mm Can copy to up to 1 switches simultaneously.

More information

2-Colour Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2m) L For positive pressure For vacuum/low

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4 Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Pressure measurements can easily be taken any time, anywhere. RoHS Compact and lightweight Portable type with a lightweight of only about 00 g (unit 50 g, battery 50 g) can also be held

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics The ZSE3/E3 series is to be discontinued. We recommend you consider using the Z/E10 series or the

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

Series PSE560 Pressure Sensor For General Fluids... 90

Series PSE560 Pressure Sensor For General Fluids... 90 Table of Contents Pressure Switch Selection Guide... Electronic Pressure Switch... Mechanical Pressure... Pressure Switch Application Example... Series SE/ISE High Precision, 2-color Display Digital Pressure

More information

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter Clean Air Module Series Digital flow switch Regulator ON/OFF valve Restrictor Filter Modularizes clean equipment (Reduced piping man-hours/space-saving). Easily obtains clean air. Built-in one-touch fitting

More information

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting Controller Series PSE100 How to Order PSE10 Output specifications 0 NPN output 1 PNP output Mounting A B Option Without cover C With cover Panel mounting Wall mounting, DIN rail Controller Specifications

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in) Compact acuum Unit Ejector/acuum Pump System Quick response Compact/ Lightweight Response time of the : 5 ms acuum response time: 28 ms (Shortened by 25%; Comparison with other SMC products) Conditions:

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES 76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids Leakage rating: 1 X 10-9 atm cc/s With Backlight Digital Pressure Switch Series ZSE6B (For vacuum) ISE6B (For positive pressure) Sensor and fitting section are electron beam welded. 2 kinds of metal gasket

More information

±0.18 F (±0.1 C) 88 lb (40 kg) 104 lb (47 kg) 152 lb (69 kg) 161 lb (73 kg) With heating function. Convenient functions

±0.18 F (±0.1 C) 88 lb (40 kg) 104 lb (47 kg) 152 lb (69 kg) 161 lb (73 kg) With heating function. Convenient functions Circulating Fluid Temperature Controller Thermo-chiller Lightweight/Compact Temperature stability Compact Type ±.18 F (±.1 C) HRS5 New New HRS6 (UL Standards) ( HRS3/6: Pending) RoHS HRS12/18/24 New HRS3

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

CONTROLLERS & SPECIAL VALVES

CONTROLLERS & SPECIAL VALVES CONTROLLERS & SPECIAL VALVES G75-C 1, 2 & 4 Valve Controllers.... 70 G75-C-1W & 1W+ Window Controller... 72 G75-DP Differential Pressure Switch.....................................................................

More information

Digital Flow Switch (Integrated display type)

Digital Flow Switch (Integrated display type) PRODUCT NAME Digital Flow Switch (Integrated display type) MODEL / Series / Product Number PF2A7##H Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts

More information

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil Ionizer / with surface potential sensor Series IZS0 How to Order 00 0 00 00 Ionizer IZ S 0 0 Bar length Bar length 00 mm 0 mm mm 00 mm 00 mm Ionizer Made to Order Bar type Size Electrode needle material

More information

Models SPG5A and SPG6A

Models SPG5A and SPG6A No. CP-SS-1881E Models SPGA and SPG6A Sapphire capacitance diaphragm gauge Overview The SPGA/6A is a capacitance diaphragm vacuum gauge that uses a sapphire capacitance pressure sensor to achieve high

More information

Series ISA. Air Catch Sensor. For Detection of Work Presence

Series ISA. Air Catch Sensor. For Detection of Work Presence ED Bar graph for easy calibration The ED bar graph indicator in conjunction with the adjustment knob for the variable orifice allows for easy and correct calibrations. Over range (Red) Correct range (Green)

More information

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm. SERIES LED Display Anti-corrosive Digital ure Sensor DP3 ure Measurement of Corrosive Gases and Liquids Possible! Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless

More information

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1. Thermo-cooler Series HRGC Specifications HRGC//5 Cooling method Refrigerant Control method Ambient temperature/humidity Circulating fluid Note ) Temperature range setting Note ) C Cooling capacity Note

More information

CDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

CDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION QUICK FLOW CDT1 series Digital Flowmeter for ir Conditioning pplication OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:

More information

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor

More information

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model Suction Filter with Case FH99 Series RoHS Compact and lightweight The compact and lightweight design employs an aluminum casted housing. Prevents pump cavitation The inlet size is larger than the outlet

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

Space Saving Vacuum Ejector / Vacuum Pump System

Space Saving Vacuum Ejector / Vacuum Pump System CT.US0-1'-UK Space Saving acuum jector / acuum ump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter jector ump System NW asy-to-use

More information

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector Non-rotating Type High Precision Scale Cylinder Series CEP1 ø12, ø How to Order CEP1 12 0 F9N L F High precision scale cylinder Mounting bracket Direct mounting front tapped type Foot type Front flange

More information

INSTRUMENTATION & CONTROL

INSTRUMENTATION & CONTROL Irrigation Controller.................... 172 Window Controller.................... 174 Water Meter Controller.................. 176 Digital Level Switch.................... 177 Filtration Controller Set..................

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications Manifold Regulator Modular Type /3000 Series modular type that can be freely mounted on a manifold station. Optimal for central pressure control. Easily set up using the new knob. lso has a One-touch lock

More information

4 Note 1) Value for communications type. (PROFIBUS DP)

4 Note 1) Value for communications type. (PROFIBUS DP) Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

Speed Controller with Indicator

Speed Controller with Indicator Speed Controller with Indicator The numerical indication of flow rate knob rotations reduces flow setting time and setting errors! Elbow Universal Brass Electroless nickel plated RoHS Stainless steel 1

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features. Data sheet 405052 Page 1/10 JUMO DELOS SI Precision pressure transmitter with switching contacts and display Application Food & pharma CIP/SIP systems Machine and system construction Air conditioning and

More information

Space-saving installation Flexible motor mounting

Space-saving installation Flexible motor mounting Space-saving installation Flexible motor mounting compatible!! Pulse train input compatible Automatic actuator recognition Addition of new controller compatible with pulse trains Enables current position

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading. Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor "Cube" Type Differential Pressure Sensor with LED Display Offers High Precision Sensing 31 (1.) x 3 (1.18) x 3 (1.18) mm compact-cube style saves mounting space Easy-to-read

More information

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold Pressure range 9 Option. MPa. MPa.9 MPa kpa Option How to Order N Power supply voltage 24 VDC ±% 2 to VDC Option

More information

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42) Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide

More information