The VX-6 smoke control dampers are designed for smoke control systems in buildings outfitted with a one-stage
|
|
- Paulina Lee
- 5 years ago
- Views:
Transcription
1 OE CONTROL in libraries of EI 1 (v ew h owi o) 1 C 0 multi EN 66: EN 1218: Certificate of Constancy of Performance 1CPR03/ Damper tightness class: 4 Casing tightness class: C EN51:2 FUNCTION The smoke control dampers are designed for smoke control systems in buildings outfitted with a onestage evacuation scenario based on the fireaffected zone separation principle. The dampers meet the requirements for buildings where in the event of a fire the affected zone should be isolated from the other zones, and the escape routes should be protected by means of mechanical smoke control system. The performance criteria are satisfied in case of fire from inside to outside of damper as well as outside to inside or both, respectively. PPLICTION The dampers can be used in multi compartment systems and should be activated automatically. The dampers may be used in smoke control systems as well as in combined smoke control and environmental systems. Dampers installation is allowed within a duct passing through a vertical or horizontal building partition or directly in vertical or horizontal building partition. The dampers are designed for use in systems over the range from the negative pressure of 1 Pa up to a positive pressure of Pa. DECRIPTION The GRYFIT consists of: rectangular casing made of galvanized steel sheet alternatively stainless or acid proof steel, movable damper blade made of fire resistant board, combination of smoke and fire proof seals of damper blade, control mechanism and optional E module enabling fire damper assessment with the TZ tester. OE CONTROL 1
2 12 CONNECTION OPTION Round sleeve connection Rectangular flange connection Rectangular sleeve connection DIENION OF DPER WIT FLNGE CONNECTION FOR RECTNGULR DUCT effective area [dm 2 ] = ((L30) x ())/4 where L and in mm weight [kg] correction value for acoustic calculations. For dimensions not listed in this table, assembly in multiple arrangement of fire dampers is provided L 8 3,1 0, 3, 0,63 4,2 0,60 4,8 5,6 7,3,0,5,7 12,4,1 15,8 0,,5,2 2, 0,7 4,0 0, ,1 0,57 5,4 6,3 0, ,3,5,7 12,3,,1 0, 18,3 0,27,5 0,,7 0, 24, 3,5 0,78 4, 0,65 6,2 6,6 7,6 0,47 8, 0,,6 0,36,3 15,1,0 0,,7 0,,4,1 0, 27,8 0, 30,5 0, 3,7 0,77 5,1 0, 6,6 7,0 8,0 0,,4 12,3 15,1,0 0, 18,0 0,,8 0,,7 0,,5 0,,4 3,3 0,68 15,7 0,53,0 0, 21,3 24,4 36,7,4,1 48,7 0, 54,8 0, 63,5 0, 7 0, 80, 8,6 8,3,0 0,6, 0,53,7 0, 18, 21,6 0,36 33,4 33,1,8,1 48,5 0, 56,2 0, 63, 0, 71,6 7,3 87,0 8,7 0, 12,1 0,54 15,4,4 18,8 0, 30,1 0,,8 0,,5 0,,5 4 0, 48, 0,,6 0, 62,3 6,0 75,7 7,8 0,, 0,54 24,8,7 0,, 0,,8,8 0,,8 0, 33,6 0,,8 0,,8 0,,8 0, 47,8 50,8 53,8 56 7,4 0,71,3,1 0,,0 0,, ,8 24,5 0, 30,2 0,, 0,,,6 0, 47,3 0, 53,0,7,4 6,1 0,72 8,5 0,57,8 0,48,5, ,5,2 0,,0 0,,3 0,,6 0,,3 0, 3,0 0,,7 0, 48,4 0, 53,1 4,8 0,75 6,7 0,5 8,5 0,50,1 0,47, ,,6 0,,7 0,,2 27,0 0, 30,7,4 0,,1 0,,8 0, 4,2 0,75 5,8 0, ,4 7,8 0,50,0 0, 18,6,8 0,,0 0,, 0,27,2 0,,4 0,,6 0,,8 33,0 0, 36,2 0,,1 0,66 47,5 33,8 36,0, ,5 0, 63,2 0, 77, 0, 82,3 0, 2,6 0, 7,3,4 45,2 0, 0,0,8 0, 24,7,5 33,6 51, 0, 72,6 0, 76,7 0, 86,3 0, 66,5 0,,,2,1,6 48, 0, 54,6 0,,3 0, 71,1 0, 80,0 0, 2,7 5,4 15,2 0, 21,1,,7,8 45,6 0, 50,3 0, 62,0 0, 65,5 0, 73,7 0, 85,4 7,1 8,8, 0,68,7 24,6,2 30,0 42,3 0,,0 0, 56,7 0, 5, 0,,4 0, 78,1 88,8,5 12,6 0,68,5,3,8 27,2 3,0,7 0, 51,4 0, 54,3 0,,1 0,,8 0, 80,5 0,2,,6
3 INTLLTION OF OE CONTROL DPER IN PRTITION WLL CRCTERITIC OF DPER WIT FLNGE Detail Detail B Detail C B C 30* F G P= R5.5 * Option of mm flange is available. ** For mm flage value of this dimension is 2 mm. ** L x Lr x r Table of dimensions for brick/concrete partition wall G=1 mm (F,, P) F P [mm ] [ mm ] [mm ] [ mm ] [ mm ] ,5 30,5,5 63,0 80,5 5,5 1,5 5,5 2,5 5,5 305,5 5,5 5,5 4,5 505,5 45,5 5,5 1,5 5,5 5,5 245,5 5,5 5,5 35, * When the partition wall has a different thickness than 1, custom damper casing width P is possible. Use the following formulas to calculate the parameters = G P = G F = /2 24,5 as in the table above inimum partition wall thickness G=1 mm. CRCTERITIC OF DPER WIT LEEVE FOR ROUND DUCT P C B DITNCE REQUIRED FOR INTENNCE D D Lx P B C Weight [mm ] [ mm ] [ mm ] [ mm ] [ mm ] [ mm ] [kg] [ ] [ dm 2] ,0 3,0 3,0 3,0 3,0 0,0 0,0 0,0,0,0 5,0 6,0 6,0 7,0 8,0,0,0,0,0,0,0,0,0,0,0 450,0,0,0,0,0,0,0 450,0,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 215,0 5,0 5,0,0 365,0 5,0 5, ,66 0, 0, 0, 0, 0, 0, 0, 4,0 6,2 7,0,0 1,2 30,2 33,6 4,2 7 0,2 Detail Lr x r 1** min.* 1 Installation of smoke control dampers in partition: horizontal vertical inimum installation opening: Concrete, brick or light weight partition walls L r x r = (L + 0) x ( + 0) ortaring border: is clearly marked by the label on the casing damper blade should align with the center line of the partition wall s thickness (for construction elements of 1 mm thickness) should always be respected to maintain the declared fire resistance of damper *inimum required distance for maintenance of mechanism **Drawing shows damper with mechanism i.e. electromagnet and FDG8 actuator. In case of DG15 actuator height is 1 mm The GRYFIT smoke control damper can be installed with its blade axis positioned horizontally as well as vertically.
4 INTLLTION IN VERTICL LIGT WEIGT GYPU BORD PRTITION Detail L x Lr=L+0 x r=+0 min. 0 It is recommended to carry out damper installation with means of 8 installation brackets fixed to the damper casing. Brackets have to be bended before installation. Installation brackets assure that mortaring border is respected. The minimum thickness of light weight gypsum boards partition is mm. INTLLTION IN ORIZONTL PRTITION L r=l+0 x r=+0 L x L x L r=l+0 x r=+0 Damper installation with mechanizm above horizontal partition should be carried out with means of 8 installation brackets fixed to the damper casing. Brackets have to be bended before installation. Installlation brackets assure that mortaring border clearly marked by the label on the casing, is respected. The minimum thickness of the horizontal partition is mm. Damper installation with mechanizm below horizontal partition should be carried out with complementary installation brackets. tandard complementary brackets delivered by anufacturer correspond to partition thickness of mm. In case of thicker partitions it has to be specified when ordering. ortaring border has to always respected. Note: anufacturer installation and operation manual instructions that are delivered together with smoke control damper should be carefully read before beginning installation, especially in case of installation in horizontal partitions, in lightweight partition walls or in batteries.
5 DPER EBLY IN BTERIE Dampers are arranged in batteries in case of ventilation ducts of very large crosssection, for which the use of dampers selected from the standard dimension range is not possible. Dampers are connected each other by means of steel C profiles, which are mounted to the flanges of the dampers and set of screws. Noncombustible fire protection spacers equipped with set of gaskets has to be placed between each damper arranged in battery assembly. Instalation opening = (L 1+L 2)+0 Battery assembly of 4 dampers 2 1 = Instalation opening = (1+2)+0 = L 1 L 2 L=L 1+L 2+65 L=L 1+L 2+65 ELECTION & DIENION Pressure drop P [Pa] and sound power level values Lw [db()] L w acoustic pressure level inside damper [db()] correction value from tables on pages 3 and 4 [] Example: ir flow = [m 3 /h] = [] Lx = x [mm] L w = [db()] = 7,0 [dm 2 ]? P = 4 [Pa] ir flow [m 3/h] Correction value for acoustic calculations = 0,1 efective velocity V k [m/s] q v = m 3 /h efective velocity V k [m/s] ,2 0,3 0,4 0,5 0,7 0,8 0, 6 0, Lw = 30 db Effective area [dm 2] Pressure drop [Pa] 15
6 ELECTRICL WIRING DIGR OE CONTROL DPER WIT ELECTOGNET ND ICROWITCE Electrical wiring diagram for electromagnet and microswitches E 24V DC (+) () 0V C N L ELECTROGNET CRCTERITIC upply voltage 24/48V DC impulse 0V C impulse Power input 3,5W 5,5 V OE CONTROL DPER WIT DG15 CTUTOR Electrical wiring diagrams for DG15 actuators + C/DC 24 V N L C 0 V ICROWITCE R L + C/DC 24 V N L C 0 V ICROWITCE R E L < 5 < 80 <5 <80 CTUTOR CRCTERITIC ctuator type DG1524 upply voltage 24V C/DC Power consuption otor (otion) 7W Power consuption tandby (end position) 1,5W Running time otor <30s Torque motor 15Nm Protection class IP54 ound power level otor 47dB() DG 0V C 7W 1,5W <30s 15Nm IP54 47dB()
7 ELECTRICL WIRING DIGR OE CONTROL DPER WIT ELECTOGNET ND CTUTOR Electrical wiring diagrams for electromagnet and FDG8 actuators + + DC 24 V C 0 V ICROWITCE Yellow Green wire 0V only E DC 24 V C 0 V ICROWITCE <5 <80 Yellow Green wire 0V only E E <5 <80 ELECTROGNET CRCTERITIC upply voltage 24/48V DC impulse 0V C impulse Power input 3,5W 5,5 V CTUTOR CRCTERITIC ctuator type FDG824 FDG80 upply voltage 24V C/DC 0V C Power input during tensioning the spring 3,5W,2V Time of movement engine 71s 71s Time of movement spring 21s 21s Torque motor 8Nm 8Nm Protection class IP54 IP54 ound power level actuator 47dB() 47dB() ound power level spring db() db() EXPLE OF PECIFICTION ND PURCE ORDER Enquiry smoke control damper, EI1, Lx=x, damper casing made of galvanized steel, flange 30 mm, equipped with DG1524 actuator and E module suitable for connection TZ tester. Design changes reserved. ll rights reserved. GRYFIT air handling intelligence 15.0C.1ENG. GR YFI T q uotation, EI 1 (v ew h ow i o 1 C 0 multi Lx=x, Galvanized steel, P30+ DG E
NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION
air handling intelligence FIRE SFETY Fire Damper in libraries of EI 10 (v e -i o) S EN 13501-3+1:01 EN 15650:0 Certificate of Conformity 1488-CPD-081/W EUROPEN PTENT PPLICTION EP 01158318 GOLD MEDL MTP
More informationVX-6V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of
SMOKE CONTRO in libraries of EI 1 (v o) S 1500a ed i AA multi EN 166-10:11 EN 12101-8:11 Certificate of Constancy of erformance 1812-CR-.../15 1060 FUNCTION The smoke control dampers are designed for smoke
More informationBX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of
FIRE SAFETY Fire Valve in libraries of EI 60 (v e -o i) S EN 131-3+A1:10 EN 156:10 Certificate of Conformity 1488-CPD-02 82/W FUNCTION The fire valves are designed for buildings where in the event of a
More informationFDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts
Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings
More informationDKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.
Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type
More information7/S1 FIRE DAMPER PPZEN. v 2.5 (en)
7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...
More informationFIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS
FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages
More informationFire damper ETPR. Specifications. Product code example Fire damper ETPR
Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.
More informationTPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD
FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers
More informationTPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB
Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,
More informationETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE
FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the
More informationFire Dampers. Types FKA FRL FRK 4/1/EN/1
Fire Dampers Types FKA FRL FRK /1/EN/1 Contents Description Description... Construction... Standard Sizes Installation Details... Functional Description Product Range... Accessories... Circuit Diagrams...
More informationType KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU
Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of
More informationFire damper FK120/FK90 TECHNICAL DATA
Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured
More informationM A D E L. FOK-EIS-180 Fire dampers CE
M A D E L EN 60: FOK-EIS-80 Fire dampers CE The fire dampers FOK-EIS-80 work as a separator between two sectors of fire and ensure the same fire resistance that the structural elements of compartmentalisation,
More informationFire/smoke damper EKO-JBG2
Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.
More informationFire Dampers Catalogue
Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in
More informationCombustion gas damper EKO-JB
EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor
More informationPKI-C Cartridge Fire Dampers
Fire Safety Products / 7 PKI-C Cartridge Fire Dampers Fire resistance class EI60S, EI90S and EI0S 96 - CPD - 000 Ordering codes Fire resistance class PKI-C-EI - 60S, 90S and 0S Codes section. The thermal
More informationFire/combustion gas damper EKO-JBL
Fire/combustion Description The fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting. The damper is designed
More informationPKIR3G, PKIS, PKIS3G and PKIS3GA
PKIR3G, PKIS, PKIS3G and PKIS3GA Fire Dampers Fire resistance EI60S, EI90S and EI120S 1396 - CPR - 0076 1396 - CPR - 0077 1396 - CPD - 0062 Ordering codes Dimensions Type of activation PKIR3G 1) - ødn
More informationU X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)
CODIFICATION CONSTRUCTION Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The
More information(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.
Fire damper pl-30 General characteristics Application Fire dampers prevent fire and smoke from spreading through ventilation ducts in buildings. The dampers are intended for use inside buildings and are
More informationFire dampers ETCE and ETCS TECHNICAL DATA
Fire dampers ETCE and ETCS TECHNICAL DATA 2 Fire dampers ETCE and ETCS Veloduct ETCE fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 13662.
More informationBevent Rasch BSK6. - Fire /04/2017
Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product
More informationOPTIVENT Housing HVSA, HVSL
OPTIVENT Housing HVSA, HVSL Key features Variable air flow Constant air flow Real time air flow display with compact controller 227VM The HVSA and the HVSL are apartment-specific room ventilation regulators
More informationFire/combustion gas damper EKO-JBG
Fire/combustion EKO-JBG Description The EKO-JBG fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting.
More informationFire/smoke damper EKO-SRBG1
Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.
More information7/S6 FIRE DAMPER FDC40. v 2.9 (en)
7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with
More informationMULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA
MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA 96 - CPR - 0 ORIGINAL INSTALLATION, MAINTENANCE AND OPERATION MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! / PP-5_0604 DKISMA
More informationPressure control damper ERPA
Key features Constant pressure Real-time pressure monitoring with FW compact controller Can be connected to Modbus Available in IPSUM compatible version ERPA is a rectangular pressure control damper for
More informationVariable Air Volume Dampers
OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control
More information7/S5 FIRE DAMPER FD40. v 2.9 (en)
7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire
More informationRectangular smoke damper (remote controlled)
Clapets coupe-feu et Volets de désenfumage D.A.S. Organisme Certificateur AFNOR Certification - www.marque-nf.com VU10 Rectangular smoke damper (remote controlled) Rf-Technologies nv - Lange Ambachtstraat
More informationJVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6
1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators
More informationseries CEVH Smoke Evacuation Damper
series CEVH Smoke Evacuation Damper www.koolair.com Series CEVH 1 CONTENTS Description 2 Dimensions 4 Installation 5 Assembly 6 Electrical connections 7 Technical data 8 Coding 10 2 Series CEVH Description
More informationSMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS
SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00
More informationFire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3
SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za
More informationKSOF Fire damper valve
KSOF Fire damper valve KSOF is developed for use as a fire damper valve in exhaust ventilation systems. Fire damper valve KSOF is CE marked based on product standard EN 156: and tested according to test
More informationSystemair Fire Dampers
Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S www.systemair.com As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. fire dampers
More informationMotorized Fire Dampers
Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and
More informationRVP-R- VAV controller. In explosion-proof version
VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units
More informationSystemair Fire Dampers
Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class
More informationBevent Rasch BSK Fire /04/2017
Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product
More informationU X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)
Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The handling and installation
More informationUTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper
Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,
More informationB. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.
PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationAdditional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex
Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200
More informationClassic Rolling Shutters and Classic Rolling Grilles
Classic Rolling Shutters and Classic Rolling Grilles Technical Manual: Issue 01.04.2015 Abbreviations Used B U = Width of the steel subframe DHV = Loss of passage height ET DMS = Minimum fitting depth
More informationDCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description
DCV-CF Pressure controlwith airflow measuring 24VAC + Communication Pressure control with airflow measuring DCV-CF DIN 24VAC + Communication AIN AOUT SMART DAMPERS & MEASURING UNITS PRESSURE & FLOW DCV-CF
More informationOptima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:
Perforated Ceiling Diffusers OPTIMA ceiling diffuser with perforated face, are recoended for heating, ventilating and cooling in centralized air conditioning systems. Perforated face diffusers, with 4-3-
More informationHeights up to 1000 mm Fire resistance period up to 120 minutes
Maintenance-free FK90 fire dampers - series FK120 - Heights up to 1000 mm Fire resistance period up to 120 minutes Fire classification: EI 30/60/90/120 (ve - ho, i o) S C10ooo Hygiene certificate Environmental
More informationCFSD Series. Product Description
COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke
More informationTECHNICAL AND OPERATIONAL DOCUMENTATION
Ver. PL1 10.04.08 ul. Grzegorza z Sanoka 2 80 408 Gdańsk tel. +48 58 341 42 45 TECHNICAL AND OPERATIONAL DOCUMENTATION Overpressure-bleed damper of mcr PL1 type FIRE VENTILATION SYSTEMS DEPARTMENT GDAŃSK
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single
More informationRectangular smoke damper (remote controlled)
NF-Clapets coupe-feu et Volets de désenfumage D.A.. NF 264 www.marque-nf.com VU120 Rectangular smoke damper (remote controlled) Rf-Technologies nv - Lange Ambachtstraat 40-9860 Oosterzele - Belgique -
More informationSmoke control damper RKI-90 Test certificate Z
Resistance class EK90 within smoke extraction ducts that have a fire resistance time of 90 min Ordering example / dimensions smoke control damper consisting of the housing with cut-off damper designed
More informationAir displacement diffusers - p 202. Diffusers with rotating nozzle - p 215. Alum jet diffusers - p 221. Steel jet diffusers - p 225
0,5 0,4 0,3 0,25 0,2 0,16 0,12 0,1 0,08 0,06 0,05 0,04 0,03 0,025 0,02 0,3 0,4 0,5 0,6 1 1,5 2 2,5 3 4 5 125 2 315 ir displacement diffusers - p 202 Diffusers with rotating nozzle - p 215 lum jet diffusers
More informationSmoke damper EKO-SRB1
Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation
More informationPK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.
Systemair Fire Dampers for Explosive Areas Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S www.systemair.com Description Fire damper (hereafter referred to as damper) is a fire
More informationTechnical information
6-8 Application Rectangular NK and NL types are pressure-independent VAV and CAV air volume control terminals. The terminals are designed particularly for systems with large air volumes and duct sizes
More informationRVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems.
RVP-R VAV REGUATORS Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems. Intended use VAV regulators are used for automatic airflow regulation
More informationActionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects
March 06 A-60 Marine Fire Dampers Tests and Approvals A60 Fire Rated. Lloyds Register of Shipping Approved. Marine Equipment Directive compliant. USCG Approved. Germanischer Lloyds Approved. American Bureau
More informationFire Safety Products. Product Overview
Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Fire Safety Products Product Overview SAFETY PRODUCTS prevent the spread of
More informationPower consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive
Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V
More informationFire damper BKA-EN. with general technical approval Z tested according to DIN EN
Fire damper BKA-EN with general technical approval Z-41.3-667 tested according to DIN EN 1366-2 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980
More informationSMOKE DAMPER - CLASS F MODEL BMSD
UL CLASSIFIED DAMPERS SMOKE DAMPER - BMSD SERIES STANDARD CONSTRUCTION Standards: Designed and tested in accordance with UL555S. Meets NFPA 90A and SMACNA requirements for fire & smoke dampers. Application:
More informationETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance
ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance 07/2013 Fläkt Woods FIFLO EN 2013.07 2 ZU CLOSED AUF OPEN Fire damper ETPS-EI Contents Operation and Maintenance
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation
More informationDVAX-ARS. Roof-mounted unit for mechanical smoke extract
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans DVAX- Roof-mounted unit for mechanical smoke extract 2 DVAX DVAX- Roof-mounted axial fan unit
More informationRegulation and shut-off damper SPB and SPC
SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are
More informationto obtain the specified voids due
ARABIAN THERMAL AIRE INDUSTRIES NEW RANGE OF TESTED & CERTIFIED SOUND ATTENUATORS Arabian Thermal Aire Industries PO Box 1125, Jubail Industrial City, Saudi Arabia -319611 Tel: +966133415857 Fax: +9661334116311
More informationRectangular fire damper TFER 30. pag. C-10
pag. C-10 Description Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN 1366-2, classified EI 120 S in accordance to EN 13501-3. Removable shifted kinematic
More informationCombustion gas damper EKO-SRB
Combustion EKO-SRB Description The EKO-SRB combustion is a Class E60 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment
More informationType WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES
Homepage > Products > External Louvres & Dampers > External weather louvres > External weather louvres > Type WG Type WG External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS,
More informationRegisters for spiral ducts
Registers for spiral ducts RGS-3 5 The RGS-3 is a supply/return register with adjustable double deflection blades and a volume damper designed specifically for direct mounting on a spiral duct. The use
More informationESAS Smoke control damper
ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS
More informationCOMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)
UL CLASSIFIED DAMPERS COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES STANDARD CONSTRUCTION Standards: Designed and tested in accordance with UL555 & UL555S. Meets NFPA 90A and SMACNA requirements for fire &
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation
More informationWALL VENTILATION GRILLES CBP
WALL VENTILATION GRILLES CBP 01.10-01 CBP WALL VENTILATION GRILLES Description Designed for ventilation and air-conditioning installations, where control of air flow and direction of the air is required.
More informationShutter Fire Damper Type FSD GFSD 4/1.1/B/1
Shutter Fire Damper Type FSD GFSD /./B/ Contents Description Description... Construction... Installation Details... Control Accessories... Technical Data... Order Details... 7 8 9 FSD-L GFSD-L FSD Fire
More informationFSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD36, FSD36LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 2 PPLICTION Ruskin FSD36 Series low leakage
More informationCAV-S Mechanical constant volume fl ow controller, steel
Product description Function description Features Product description The mechanical constant fl ow volumetric controller CAV-S is made of galvanized steel and works independently without requiring additional
More informationBlast Protection Damper
Protection Damper plate shown as transparent height width 250mm wide 6.35mm thick blast plate bolted to damper frame 178mm 250mm standard depth 76mm standard flange Application The damper is designed for
More informationSEMI RIGID THE PROFESSIONALS CHOICE
SEMI RIGID THE PROFESSIONALS CHOICE for efficient, high performance MVHR ductwork installations. SAP APPENDIX Q LISTED brookvent.co.uk FITTING OUTLINE THE PROFESSIONALS CHOICE for efficient, high performance
More informationSafidDampers SPK Description. Standard Construction SPK ( Flange Type )
( Flange Type ) SPK 30-300 Description SPK 30 - Series The single and multi-leaf s with extruded aluminum airfoil blades are designed for quite, efficient and reliable air volume control in air conditioning
More informationCONTROL SMOKE AND BALANCING DAMPERS
(UK) Limited CONTROL SMOKE AND BALANCING DAMPERS 00 SERIES - UNIVERSAL F e a t u r e s Robust construction of galvanised steel, with stainless steel options Opposed or parallel blade pattern Unsealed,
More informationINDEX. Chapter3. air master. Linear Bar Grilles
Chapter3 INDEX A Linear bar grilles: 1. Supply linear bar grille...: ASLG...3.1 2. Supply linear bar register...: ASLR...3.2 3. Return linear bar grille...: ARLG...3.3 4. Return linear bar register...:
More informationNEW. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.
January 2008 A-60 Marine Fire Dampers Includes new casing depths and thickness, Atex rated motor and visual indication options. NEW A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore
More informationModel DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features
Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades
More informationFSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD60, FSD60LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 1 PPLICTION Ruskin FSD60 Series ultra
More informationFitting Instructions DucoGrille Close /03/2018
Fitting Instructions DucoGrille Close 105 27/03/2018 CONTENT 1. General 1.1 Dimensions 1.2 Orientation 1.3 Actuator side 1.4 Wiring diagram Belimo NM24A 1.5 Wiring diagram Belimo NM230A 1.6 Wiring diagram
More informationPrepared By : Checked By : Approved By : Page 1 out of 6
Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box
More informationFire Damper BSK-RPR. with general building supervisory approval Z
Fire Damper BSK-RPR with general building supervisory approval Z-41.3-681 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de
More information[Y] Acoustic Splitters with spigot ends/aerodynamically shapped for energy saving (Pressure drop reduction 25% to 30%)
SLK series Splitter Attenuators Rectangular duct attenuator constructed from galvanised sheet steel, with splitter type acoustic elements. Provided with 20, 30 or 40 mm profile flanges, which are compatible
More informationLØV-R. Orion-Opus. Square supply diffuser
GB0636 06.18 Orion-Opus LØV-R Square supply diffuser Removable front panel Flush mounting Suitable for a range of ceiling systems Data provided with Luna plenum box installed Box lined with sound absorber
More informationSeries HCD Airfoil Control Damper
Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).
More informationN O V E L T Y Diffuser with particulate filter class H13
N O V E L T Y Diffuser with particulate filter class H13 NAF Atest Higieniczny: HK/B/1121/02/2007 NAF diffusers are intended to use in low- and mediumpressure ventilation systems. They are used in facilities
More informationCentrifugal fan with highly efficient EC drive motor
Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany
More information