Combustion gas damper EKO-JB

Size: px
Start display at page:

Download "Combustion gas damper EKO-JB"

Transcription

1 EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor structures. The damper is designed in accordance with the requirements of the Swedish standard VVS AMA 98, section QJC.1. The damper can also be located directly after air treatment units serving more than one fire cell. The EKO-JB combustion may also be used for direct air transfer in cases where the fire load factor does not exceed M/m. Type approval The EKO-JB combustion has been tested by Sveriges Provnings- och Forskningsinstitut (the Swedish National Testing and Research Institute) and typeapproved by SITAC (the leading Swedish construction approval agency), certificate no. 113/98. The abovementioned fire technical classification E6 applies on condition that the combustion is connected to our EKO-KE control and monitoring system, or equivalent equipment, to provide automatic functional testing at least once every 48 hours. In the case of smaller dampers, up to a maximum of x mm, installed in individual archive rooms or similar premises, the automatic functional checking system may be replaced by a manual system, with regular checks performed at least four times per year. Such checks must be logged in a register. In other respects the appropriate conditions must be maintained in accordance with the type approval. Design The EKO-JB combustion is supplied prepared for insulation in either guided or flanged design. The basic model is equipped with a factory mounted electric damper motor with spring return and end position contacts. Alternative damper motors are available if required, refer to the damper motors section. On installation the damper blades must always be horizontal. The EKO-JB combustion is manufactured of hot-dip galvanised sheet steel to environmental classification M. The smoke damper may also be supplied in alternative materials such as stainless steel 333 or acid resistant 343 for increased environmental requirements. Air tightness classification The smoke damper is equipped with a sealing gasket that seals the air side to the equivalent of class 3 in accordance with the Swedish standard for air tightness, VVS AMA 98. There is also a sealing strip around the damper frame, that expands and seals if the damper is exposed to heat. Working pressure The working pressure of the damper is max. 5 Pa, pressure class B, differential pressure with closed blades. Sizes The EKO-JB combustion is manufactured in a large number of standard sizes from x to 16x16 mm for vertical location and 1x1 for horizontal mounting.

2 Damper motors The basic EKO-JB model is supplied with a 4V electric safety motor. As an accessory the damper motor can be equipped with an EKO-TK press button switch for on site manual functional testing. Ventilation systems where the EKO-JB combustion is installed must have a smoke detector to provide an alarm and automatically close the damper. A 4V motor is always used in conjunction with the EKO-KE control and monitoring system. Alternatively the combustion can be supplied with a 3V electric motor or with a low or high pressure pneumatic motor as required. Note that the combustion must always be used with the supplied motor for type approval to be valid. Accessories EKO-KPB Junction box. EKO-RKB Control unit. EKO-RE Smoke detector (duct). EKO-RET Smoke detector (ceiling). EKO-KER Material for making good walls. EKO-KE Control and monitoring system. EKO-TK Press button switch. EKO-MFL Counter flange. EKO-INR Wall frame. Maintenance We recommend preventive maintenance of the damper as required by the plant in which it is installed. The damper blades and interior surfaces are cleaned with a brush, vacuum cleaner or by wiping down. NOTE Water or other liquids must not be used. Other movement requirements apply, in accordance with the type approval. How to order the EKO-JB Designation: EKO-JB-A-B-C-D A B C D SIZE MATERIAL CONNECTIONDAMPER MOTOR (Width x Height) 1 = Galvanized 5 = Flange 7 = Damper motor 4 = Aluzinc (M3) 6 = Guide 8 = Damper motor 3 = Stainless steel SS = Pneumatic 4 = Stainless steel SS 343 Example: 1 EKO-JB-4x-1-6-7

3 Technical data EKO-JB Dimensions A 19 A Standard sizes 35 B 6 *) 15**) C spacing n = C C spacing n = C *Applies to guide type **Applies to flange type B A or B C Number spacing n Weight for standard sizes* A B * Weight in kg, including damper motor.

4 Air tightness classification 1 VVS-AMA98 Classification class Differential pressure, Pa Damper leakage factor l/(s. m ) Pressure drop and sound power level 1 Static pressure drop, Pa L WA (db) Air velocity, m/s Correction of sound power level L WACORR for different sizes. L WACORR = L WA + K 1 Damper area K Correction of sound power level L WAOC for different sizes. L WAOC = L WACORR + K OC Octaveband Openingangle K K 4K 8K K OC Sound power level measured in accordance with ISO 3741 and ISO 5135 by Sveriges Provnings- och Forskningsinstitut (the Swedish National Testing and Research Institute).

5 Installation and insulation instructions Construction area (wall or floor structures) in fire technical classification EI6. Type approval no. 113/98. * L=EI15 L=EI3 L=EI3 L=EI15 EKO-JB Make good with EKO-KER or type approved fire sealant Important! The combustion s must always be installed with the pivot shaft horizontal Fire protection requirements in accordance with the applicable BBR. Dampers installed into the last fire cell or for air transmission in ventilation ducts must not be terminated closer than prescribed in the diagram below. Ducting must be insulated against the spread of fire in accordance with the following diagram. Insulation lengths are based on test results from Sveriges Provnings- och Forskningsinstitut (the Swedish National Testing and Research Institute). Branch connections to insulated ducting Branch connections are insulated in accordance with the diagram. The length of insulation is defined from the damper blade for the respective branch dimensions and radiation level. * Ducting is insulated from the fire cell boundary up to and including the damper blade, in accordance with the fire classification of the pierced construction. 9 Against combustible material Surface temperature 16 C (kw/m ) 7 Against a cavity Surface temperature 7 C (3kW/m ) Insulation length L (m) EI15 EI3 Insulation length L (m) EI15 EI3 1 1,, 1,8 1,6 1,4 1, 1,,8,6,4,, 1,8 1,6 1,4 1, 1,,8,6,4 Diagonal measurement (m) Diagonal measurement (m)

6 Table for diagonal calculation Width Height It is assumed that rectangular ducts with sides larger than.5 m have been reinforced in accordance with applicable regulations. The diagonal measurement (x) is to be used on rectangular ducts to obtain the correct insulation length, see diagram. Example: Duct width 14 and height 8 gives the value 1.6. Go in to the diagram at diagonal measurement 1.6 where the required insulation length is specified. The combustion is connected to the control and monitoring system EKO-KE. Insulation thickness* Mat Sheet EI6 14 mm 1 mm EI3 7 mm 6 mm * According to applicable type approval certificate for insulation. X X 3,5 Air space to combustible material Surface temperature 375 C (1kW/m ) Minimum insulation lengths for duct sizes to EI3 3, EI15 EI3 Diagonal measurement Min isolation length EI3 (m) Insulation length L (m),5, 1,5 1,, ,, 1,8 1,6 1,4 1, 1,,8,6,4 Diagonal measurement (m)

Combustion gas damper EKO-SRB

Combustion gas damper EKO-SRB Combustion EKO-SRB Description The EKO-SRB combustion is a Class E60 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment

More information

Fire/combustion gas damper EKO-JBL

Fire/combustion gas damper EKO-JBL Fire/combustion Description The fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting. The damper is designed

More information

Fire/combustion gas damper EKO-JBG

Fire/combustion gas damper EKO-JBG Fire/combustion EKO-JBG Description The EKO-JBG fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting.

More information

Fire/smoke damper EKO-JBG2

Fire/smoke damper EKO-JBG2 Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

Smoke damper EKO-SRB1

Smoke damper EKO-SRB1 Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation

More information

Fire/smoke damper EKO-SRBG1

Fire/smoke damper EKO-SRBG1 Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings

More information

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm. Fire damper pl-30 General characteristics Application Fire dampers prevent fire and smoke from spreading through ventilation ducts in buildings. The dampers are intended for use inside buildings and are

More information

TYPE EK-EU SMOKE CONTROL DAMPER

TYPE EK-EU SMOKE CONTROL DAMPER Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH

More information

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

Bevent Rasch BSK Fire /04/2017

Bevent Rasch BSK Fire /04/2017 Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product

More information

Technical information

Technical information 6-8 Application Rectangular NK and NL types are pressure-independent VAV and CAV air volume control terminals. The terminals are designed particularly for systems with large air volumes and duct sizes

More information

series FSD-FLD Fire and smoke dampers UL Approval

series FSD-FLD Fire and smoke dampers UL Approval series FSD-FLD Fire and smoke dampers UL Approval www.koolair.com Series FSD-FLD 1 Fire and smoke dampers UL Approval FSD-B-U / FSD-A-U and FLD-S-U / FLD-S-UD CONTENTS Description FSD-B-U / FSD-A-U 2 Construction

More information

7/S5 FIRE DAMPER FD40. v 2.9 (en)

7/S5 FIRE DAMPER FD40. v 2.9 (en) 7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire

More information

Bevent Rasch BSK6. - Fire /04/2017

Bevent Rasch BSK6. - Fire /04/2017 Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product

More information

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description DCV-CF Pressure controlwith airflow measuring 24VAC + Communication Pressure control with airflow measuring DCV-CF DIN 24VAC + Communication AIN AOUT SMART DAMPERS & MEASURING UNITS PRESSURE & FLOW DCV-CF

More information

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

7/S6 FIRE DAMPER FDC40. v 2.9 (en) 7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with

More information

M A D E L. FOK-EIS-180 Fire dampers CE

M A D E L. FOK-EIS-180 Fire dampers CE M A D E L EN 60: FOK-EIS-80 Fire dampers CE The fire dampers FOK-EIS-80 work as a separator between two sectors of fire and ensure the same fire resistance that the structural elements of compartmentalisation,

More information

VOLUME CONTROL / REGULATING DAMPERS

VOLUME CONTROL / REGULATING DAMPERS VOLUME CONTROL / REGULATING S PRODUCT RANGE Model Range Includes A - Multi-Leaf. (Flanged - Rectangular Duct) B - Multi-Leaf. (Slip joint / Spigot - Rectangular Duct) C - Multi-Leaf. (Slip joint / Spigot

More information

series RVV Variable flow rate controllers

series RVV Variable flow rate controllers series RVV Variable flow rate controllers www.koolair.com Series RVV 1 CONTENTS Variable flow rate controllers, type RVV Description 2 Dimensions and product code 3 Selection tables 4 Variable flow rate

More information

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,

More information

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators

More information

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES. 25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages

More information

DCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description.

DCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description. DCV-RC Room climate control SMART DAMPERS & MEASURING UNITS DCV-RC Office landscape with DCV-RC. 1(18) Contents Page DCV-RC Introduction... 3 Functional chart... 4 Dimensions, Ordering format... 5 Accessories,

More information

VARYCONTROL VAV Dual Duct Terminal Boxes

VARYCONTROL VAV Dual Duct Terminal Boxes 5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product

More information

INDEX. Chapter3. air master. Linear Bar Grilles

INDEX. Chapter3. air master. Linear Bar Grilles Chapter3 INDEX A Linear bar grilles: 1. Supply linear bar grille...: ASLG...3.1 2. Supply linear bar register...: ASLR...3.2 3. Return linear bar grille...: ARLG...3.3 4. Return linear bar register...:

More information

CONTENT INTRODUCTION... 3 PRESSURE SENSORS INSTALLATION... 3 PIPES CONNECTION... 4 ELECTRICAL CONNECTION TO THE UNIT... 5

CONTENT INTRODUCTION... 3 PRESSURE SENSORS INSTALLATION... 3 PIPES CONNECTION... 4 ELECTRICAL CONNECTION TO THE UNIT... 5 CONTENT INTRODUCTION... 3 PRESSURE SENSORS INSTALLATION... 3 PIPES CONNECTION... 4 ELECTRICAL CONNECTION TO THE UNIT... 5 PRESSURE SENSORS SETTINGS... 6 VAV FUNCTION CALIBRATION... 8-2 - INTRODUCTION Variable

More information

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Fire Dampers. Types FKA FRL FRK 4/1/EN/1 Fire Dampers Types FKA FRL FRK /1/EN/1 Contents Description Description... Construction... Standard Sizes Installation Details... Functional Description Product Range... Accessories... Circuit Diagrams...

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

ESAS Smoke control damper

ESAS Smoke control damper ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS

More information

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the

More information

Fire damper FK120/FK90 TECHNICAL DATA

Fire damper FK120/FK90 TECHNICAL DATA Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured

More information

Actionair Control and Shut Off Dampers

Actionair Control and Shut Off Dampers December 2003 Air/Shield (Incorporating Energy/Shield ES35 & ES36) Actionair Control and Shut Off Dampers Air/Shield Aerofoil Air Control Dampers Air/Shield Aeroseal Air Control and Shut-Off Dampers Energy/Shield

More information

Fire Dampers Catalogue

Fire Dampers Catalogue Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in

More information

RETROFIT TERMINAL UNITS

RETROFIT TERMINAL UNITS GENERAL PROUCT OVERVIEW Retrofit Terminal s Convert Constant Air Volume Systems to Variable Air Volume. Convert Constant Volume ual uct Systems to Variable Air Volume. Convert Multizone Systems to Variable

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

Rectangular fire damper TFER 30. pag. C-10

Rectangular fire damper TFER 30. pag. C-10 pag. C-10 Description Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN 1366-2, classified EI 120 S in accordance to EN 13501-3. Removable shifted kinematic

More information

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

INDEX. Chapter1 0. air master. Round Ceiling Diffusers air master Chapter1 0 INDEX A. Round ceiling diffusers 1. Fixed round ceiling diffuser...: ARDF...10.1 2. Round ceiling diffuser with adjustable pattern...: ARD...10.2 Standard sizes...10.3 Air pattern...10.3

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS Perforated damper blade for better damper characteristic Manually adjustable blade (standard) Provision for motorised regulation Quick connection

More information

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC DCV-LC Lab climate control External occupancy detector Lab climate control unit 24VAC + Communication Occupancy DCV-LC 24VAC + Communication AIN Adjustable function AOUT Adjustable function SMART DAMPERS

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

SINGLE DUCT AIR TERMINAL UNITS

SINGLE DUCT AIR TERMINAL UNITS AIR terminal units AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units are at the core of

More information

DRUM JET DIFFUSERS. Available in Aluminium & Stainless Steel

DRUM JET DIFFUSERS. Available in Aluminium & Stainless Steel DRUM JET DIFFUSERS Available in Aluminium & Stainless Steel Introduction The JPR range of Drum Jet diffusers are high air capacity terminals designed for applications requiring a long jet throw. They are

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to

More information

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA 96 - CPR - 0 ORIGINAL INSTALLATION, MAINTENANCE AND OPERATION MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! / PP-5_0604 DKISMA

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

PKIR3G, PKIS, PKIS3G and PKIS3GA

PKIR3G, PKIS, PKIS3G and PKIS3GA PKIR3G, PKIS, PKIS3G and PKIS3GA Fire Dampers Fire resistance EI60S, EI90S and EI120S 1396 - CPR - 0076 1396 - CPR - 0077 1396 - CPD - 0062 Ordering codes Dimensions Type of activation PKIR3G 1) - ødn

More information

Series HCD Airfoil Control Damper

Series HCD Airfoil Control Damper Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).

More information

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option ZSC - Halton Zen Semi-Circle Displacement ventilation unit Capacity for wide supply airflow range. Uniform supply air distribution is achieved through small perforations, providing optimal conditions in

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8. Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type

More information

VAV TERMINAL BOXES TYPE: BA BT

VAV TERMINAL BOXES TYPE: BA BT Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500

More information

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS Ceiling mounted linear disc diffuser for supply air QUICK FACTS flexible spread pattern Facility for vertical spread Facility for simultaneous vertical/horizontal spread Large induction effect Suitable

More information

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling

More information

Registers for spiral ducts

Registers for spiral ducts Registers for spiral ducts RGS-3 5 The RGS-3 is a supply/return register with adjustable double deflection blades and a volume damper designed specifically for direct mounting on a spiral duct. The use

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES 30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an

More information

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA PH SERIES SINGLE DUCT ATU PERFORMAE DATA The Performance Aire PH Series is the simplest and most widely used VAV terminal unit. Its basic components are an insulated sheet metal box, round inlet damper,

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

NR series. Circular CAV air volume control terminals with system powered mechanical regulator series Circular CAV air volume control terminals Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 overview / dimensions 4-5

More information

Zero Leakage Isolation Damper

Zero Leakage Isolation Damper SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional spigot

More information

NV series. Induction VAV air volume control terminals

NV series. Induction VAV air volume control terminals NV series Induction VAV Description Table of contents Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model overview / dimensions 4-5 Sound data NVOAOOB...

More information

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser Halton TRB Conical Ceiling Diffuser Horizontal or vertical air supply, suitable for both heating and cooling applications Supply air jet velocity is effectively reduced due to high mixing effect Installation

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

CONSTANTFLOW Volume Flow Controllers

CONSTANTFLOW Volume Flow Controllers 5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions

More information

SMOKE CONTROL DAMPERS

SMOKE CONTROL DAMPERS SMOKE CONTROL DAMPERS 96 - CPD - 0058 Round DKIR and Rectangular DKIS ORIGINAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! /

More information

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,

More information

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Blade Features. AirShield Control and Shut Off Dampers. AirShield April 2011 AirShield AirShield AirShield Aerofoil Air Control Dampers AirShield Aeroseal Air Control and Shut Off Dampers AirShield Features and Design Guide Opposed blade dampers suitable for systems

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades

More information

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI Air Terminal Units Models MQTH, MQFCI and MQFVI Catalog 903-1 Model MQTH Model MQFCI Model MQFVI Table of Contents Single Duct Air Terminal Units.... 3 Introduction....3 MQTH-500 Single Duct Air Terminal

More information

PART F DIFFUSERS section 2 SEPT Publication. Air Diffusers. supply and exhaust ventilation systems. drum jet diffusers

PART F DIFFUSERS section 2 SEPT Publication. Air Diffusers. supply and exhaust ventilation systems. drum jet diffusers Publication PAT F DIFFUSES section 2 SEPT 2005 Air Diffusers supply and exhaust ventilation systems drum jet diffusers DESIGN FEATUES introduction The Brooke Air range of Drum Jet diffusers are high air

More information

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed

More information

TBV - Terminal Unit. Halton TBV. Terminal Unit

TBV - Terminal Unit. Halton TBV. Terminal Unit Halton TBV Terminal Unit Horizontal air supply, suitable also for exhaust Integrated rectangular balancing plenum with measurement and adjustment functions Effective sound attenuation Circular duct connection

More information

RVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems.

RVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems. RVP-R VAV REGUATORS Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems. Intended use VAV regulators are used for automatic airflow regulation

More information

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations. Model Application The is a leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper

More information

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED BC 09 Pressure Relief Dampers PRD-GAB-12B Table Of Contents S. No Description Page No 1 General Information 1 2 PRD/NRD- B10 Series 2 3 CBD - B20 Series 3 4 BDD - B30 Series 4 5 Engineering and Performance

More information

Pressure relief dampers

Pressure relief dampers X X testregistrierung Pressure relief dampers Type Closed blade For the prevention of excess pressure in rooms Pressure relief dampers for gas fire extinguishing systems and transformer substations Air

More information

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

Fire damper ETPR. Specifications. Product code example Fire damper ETPR Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.

More information

WGA Long throw nozzle grille

WGA Long throw nozzle grille Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...

More information

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX DAMPERS LSS - R LSS / SOD circular single blade shut off damper SSVent rectangular multiblade shut off damper S.Ventil R1OVL circular single blade weather tight damper/valve RD circular regulating damper

More information

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R 1/3/EN/4 Ventilation Grilles Types TRS-K TRS-R TRSE-R Contents Description Description 2 Constructions Dimensions TRS-K 3 Constructions Dimensions TRS-R 4 Constructions Dimensions TRSE-R 5 Installation

More information

Pressure control damper ERPA

Pressure control damper ERPA Key features Constant pressure Real-time pressure monitoring with FW compact controller Can be connected to Modbus Available in IPSUM compatible version ERPA is a rectangular pressure control damper for

More information

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101) 500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5

More information

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL) CODIFICATION CONSTRUCTION Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The

More information